ꯁꯔꯨꯛ 6ꯃꯥꯏꯅꯔ ꯑꯃꯁꯨꯡ ꯃꯦꯖꯔ ꯏꯔꯝ ꯁꯤꯁ꯭ꯇꯦꯝꯁꯤꯡ
6.1 ꯄꯥꯟꯗꯝ ꯑꯃꯁꯨꯡ ꯌꯥꯎꯕ ꯃꯐꯝ
6.1.1 ꯁꯔꯨꯛ ꯑꯁꯤꯅꯥ ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯑꯃꯗꯒꯤ, ꯂꯝꯕꯤ ꯑꯃꯗꯒꯤ ꯅꯠꯔꯒꯥ ꯄꯕ꯭ꯂꯤꯛ ꯏꯔꯝ (drainage) ꯁ꯭ꯀꯤꯝ ꯑꯃꯗꯒꯤ ꯔꯟꯑꯣꯐ (runoff) ꯑꯗꯨ ꯏꯁꯤꯡ ꯂꯧꯕ ꯋꯥꯇꯔꯋꯦ (waterway), ꯄꯨꯈ꯭ꯔꯤ (tank; pukhri) ꯅꯠꯔꯒꯥ ꯑꯥꯎꯠꯐꯣꯜ (outfall) ꯑꯃꯗ ꯄꯨꯕ ꯀꯟꯚꯦꯌꯦꯟꯁ ꯁꯤꯁ꯭ꯇꯦꯝ (conveyance system) ꯑꯗꯨꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯣꯐ ꯁꯔꯚꯤꯁ (level of service) ꯑꯃꯁꯨꯡ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯀ꯭ꯔꯥꯏꯇꯦꯔꯤꯌꯥꯁꯤꯡ ꯊꯝꯂꯤ꯫ ꯃꯁꯤꯅꯥ ꯃꯈꯥꯒꯤꯁꯤꯡ ꯌꯥꯎꯏ:
- (a) ꯗ꯭ꯌꯨꯑꯦꯜ ꯏꯔꯝꯒꯤ ꯋꯥꯈꯜꯂꯣꯟ (dual drainage concept): ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ (minor system) ꯑꯃꯥ ꯑꯃꯁꯨꯡ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ (major system) ꯑꯃꯥ (ꯀ꯭ꯂꯣꯖ 6.3);
- (b) ꯂꯝ ꯁꯤꯖꯤꯟꯅꯕ ꯑꯃꯁꯨꯡ ꯂꯝꯕꯤꯒꯤ ꯀ꯭ꯂꯥꯁ ꯃꯇꯨꯡ ꯏꯟꯅ ꯗꯤꯖꯥꯏꯟ ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗꯁꯤꯡ (return period) (ꯀ꯭ꯂꯣꯖ 6.4);
- (c) ꯂꯝꯕꯤꯒꯤ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛꯁ: ꯁ꯭ꯞꯔꯦꯗ (spread), ꯑꯏꯡꯕ ꯑꯃꯁꯨꯡ ꯐ꯭ꯂꯣꯒꯤ ꯍꯖꯥꯔꯗ (flow hazard) (ꯀ꯭ꯂꯣꯖ 6.5);
- (d) ꯀꯨꯞꯄ (clogging) ꯌꯥꯑꯣꯅꯥ ꯏꯟꯂꯦꯠꯁꯤꯡ (inlet) (ꯀ꯭ꯂꯣꯖ 6.6);
- (e) ꯄꯥꯏꯞꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯑꯃꯁꯨꯡ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ (open and covered drains) (ꯀ꯭ꯂꯣꯖ 6.7);
- (f) ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯒ꯭ꯔꯦꯗ ꯂꯥꯏꯟꯒꯤ (hydraulic grade line) ꯑꯦꯅꯥꯂꯥꯏꯁꯤꯁ (ꯀ꯭ꯂꯣꯖ 6.8);
- (g) ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯁꯤꯡ (overland flow path), ꯁꯦꯒꯁꯤꯡꯗ (sag) ꯏꯁꯤꯡ ꯂꯦꯞꯄ (ponding) ꯑꯃꯁꯨꯡ ꯕꯤꯜꯗꯤꯡꯒꯤ ꯐ꯭ꯂꯣꯔ ꯂꯦꯚꯦꯜꯁꯤꯡ (ꯀ꯭ꯂꯣꯖ 6.9-ꯗꯒꯤ 6.11 ꯐꯥꯎꯕ);
- (h) ꯀꯜꯚꯔꯠꯁꯤꯡ (culvert) ꯑꯃꯁꯨꯡ ꯂꯝꯕꯤ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡ (road crossing) (ꯀ꯭ꯂꯣꯖ 6.12); ꯑꯃꯁꯨꯡ
- (i) ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ, ꯂꯩꯃꯨ (silt), ꯁꯣꯂꯤꯗ ꯋꯦꯁ꯭ꯠ (solid waste), ꯌꯨꯇꯤꯂꯤꯇꯤꯁꯤꯡ (utilities) ꯑꯃꯁꯨꯡ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯛꯅꯕ ꯆꯡꯂꯛꯄꯒꯤ ꯂꯝꯕꯤ (desilting access)-ꯒꯤꯗꯃꯛ ꯃꯅꯤꯄꯨꯔꯒꯤ ꯀꯟꯁ꯭ꯇ꯭ꯔꯛꯁꯟ ꯄ꯭ꯔꯦꯛꯇꯤꯁꯀꯤ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡ (ꯀ꯭ꯂꯣꯖ 6.13)꯫
6.1.2 ꯃꯥꯏꯊꯣꯡ ꯈꯨꯗꯤꯡꯒꯤ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔꯁꯤꯡꯒꯤ (ꯀꯜꯚꯔꯠꯁꯤꯡ, ꯆꯦꯅꯦꯜꯁꯤꯡ, ꯑꯦꯅꯔꯖꯤ ꯗꯤꯁꯤꯄꯦꯇꯔꯁꯤꯡ, ꯁ꯭ꯀ꯭ꯔꯤꯟꯁꯤꯡ, ꯄꯝꯞꯁꯤꯡ, ꯒꯦꯠꯁꯤꯡ, ꯃꯦꯟꯍꯣꯜꯁꯤꯡ) ꯑꯀꯨꯞꯄ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯗꯤꯖꯥꯏꯟ ꯑꯁꯤ ꯁꯔꯨꯛ 9-ꯗ ꯂꯩ꯫ ꯅꯣꯡ ꯆꯨꯕ ꯁꯔꯨꯛ 2-ꯗ, ꯔꯟꯑꯣꯐꯀꯤ ꯊꯧꯑꯣꯡꯁꯤꯡ ꯁꯔꯨꯛ 3-ꯗ, ꯑꯣꯟ-ꯁꯥꯏꯠ ꯁ꯭ꯇꯣꯔꯦꯖ ꯁꯔꯨꯛ 4-ꯗ, ꯇꯦꯜꯋꯥꯇꯔ (tailwater) ꯁꯔꯨꯛ 5-ꯗ, ꯏꯁꯤꯡ ꯂꯩꯐꯝꯁꯤꯡ ꯁꯔꯨꯛ 7-ꯗ ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡꯒꯤ ꯀ꯭ꯋꯥꯂꯤꯇꯤ ꯁꯔꯨꯛ 8-ꯗ ꯂꯩ꯫
6.1.3 ꯁꯔꯨꯛ ꯑꯁꯤ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ (drain) ꯄꯨꯝꯅꯃꯛ, ꯀꯔꯕ (kerb) ꯅꯠꯔꯒꯥ ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟ ꯂꯩꯕ ꯂꯝꯕꯤ ꯄꯨꯝꯅꯃꯛ, ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 1-ꯒꯤ ꯆꯠꯅꯕ ꯃꯐꯝꯒꯤ ꯊ꯭ꯔꯦꯁꯍꯣꯜꯗꯁꯤꯡ (threshold) ꯌꯧꯕ ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠꯁꯤꯡꯒꯤ ꯄ꯭ꯔꯥꯏꯚꯦꯠ ꯏꯔꯝ ꯁꯤꯁ꯭ꯇꯦꯝ ꯄꯨꯝꯅꯃꯛꯇ ꯆꯠꯅꯩ꯫ ꯇꯤꯌꯔ B ꯂꯣꯀꯜ ꯕꯣꯗꯤꯁꯤꯡꯗ, ꯁꯔꯨꯛ 1-ꯗ ꯍꯥꯌꯔꯤꯕ ꯂꯥꯏꯊꯣꯛꯍꯟꯕ ꯄ꯭ꯔꯣꯁꯤꯖꯔꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯗꯤꯖꯥꯏꯟ ꯑꯦꯗꯁꯤꯡ (design aid) ꯑꯁꯤ ≤ 16 ha-ꯗ ꯁꯦꯕꯥ ꯄꯤꯕ ꯑꯦꯂꯤꯃꯦꯟꯠꯁꯤꯡꯒꯤꯗꯃꯛ ꯁꯤꯖꯤꯟꯅꯕ ꯌꯥꯏ, ꯑꯗꯨꯕꯨ ꯁꯔꯨꯛ ꯑꯁꯤꯒꯤ ꯀ꯭ꯔꯥꯏꯇꯦꯔꯤꯌꯥꯁꯤꯡ ꯑꯗꯨ ꯍꯧꯖꯤꯛꯁꯨ ꯆꯠꯅꯩ꯫
6.2 ꯋꯥꯍꯩꯒꯤ ꯑꯔꯊꯁꯤꯡ
| ꯋꯥꯍꯩ | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯗ ꯑꯔꯊ |
|---|---|
| ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ (minor system) | ꯇꯦꯕꯜ 6.1-ꯒꯤ ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ AEP ꯐꯥꯎꯕ ꯔꯟꯑꯣꯐ ꯑꯗꯨ ꯀ꯭ꯂꯣꯖ 6.8-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯕ ꯁꯔꯆꯥꯔꯖ (surcharge) ꯌꯥꯎꯗꯅꯥ ꯄꯨꯕ ꯏꯟꯂꯦꯠꯁꯤꯡ, ꯄꯥꯏꯞꯁꯤꯡ, ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ꯫ |
| ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ (major system) | ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯐ꯭ꯂꯣ ꯑꯗꯨ 1% AEP (100-yr) ꯊꯧꯗꯣꯛ ꯐꯥꯎꯕ ꯄꯨꯕ ꯂꯩꯃꯥꯏꯒꯤ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯁꯤꯡ (ꯂꯝꯕꯤꯁꯤꯡ, ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯁꯤꯡ, ꯍꯥꯡꯗꯣꯛꯂꯕ ꯆꯦꯅꯦꯜꯁꯤꯡ, ꯐ꯭ꯂꯗꯋꯦꯁꯤꯡ (floodway) ꯑꯃꯁꯨꯡ ꯁ꯭ꯇꯣꯔꯦꯖ)꯫ |
| ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤ (overland flow path) | ꯃꯦꯖꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯏꯁꯤꯡ ꯂꯧꯕ ꯋꯥꯇꯔꯋꯦ ꯑꯃꯗ ꯄꯨꯕ, ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯗ ꯅꯠꯔꯒꯥ ꯔꯦꯀꯣꯔꯗ ꯇꯧꯔꯕ ꯏꯖꯃꯦꯟꯠ (easement) ꯑꯃꯗ ꯂꯩꯕ, ꯃꯌꯦꯛ ꯁꯦꯡꯅꯥ ꯊꯝꯂꯕ ꯂꯩꯃꯥꯏꯒꯤ ꯂꯝꯕꯤ ꯑꯃꯥ꯫ |
| ꯁ꯭ꯞꯔꯦꯗ (spread) (T) | ꯒꯇꯔ (gutter) ꯑꯃꯁꯨꯡ ꯀꯦꯔꯤꯌꯦꯖꯋꯦꯗ (carriageway) ꯐ꯭ꯂꯣꯒꯤ ꯄꯥꯛꯄ, ꯀꯔꯕꯀꯤ ꯃꯃꯥꯏꯗꯒꯤ ꯊꯥꯖꯕ꯫ |
| ꯁꯦꯒ (sag) | ꯂꯝꯕꯤ ꯅꯠꯔꯒꯥ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯑꯃꯗ ꯂꯩꯕ ꯅꯦꯝꯕ ꯃꯐꯝ ꯑꯃꯥ, ꯃꯐꯝ ꯑꯗꯨꯗꯒꯤ ꯏꯁꯤꯡꯅꯥ ꯏꯟꯂꯦꯠ ꯑꯃꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯅꯠꯔꯒꯥ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯂꯦꯚꯦꯜ ꯑꯃꯗ ꯌꯧꯕ ꯐꯥꯑꯣꯕ ꯏꯁꯤꯡ ꯂꯦꯞꯂꯒꯥ ꯈꯛꯇꯃꯛ ꯊꯣꯀꯄ ꯌꯥꯏ꯫ ꯇ꯭ꯔꯦꯞ ꯇꯧꯔꯕ ꯁꯦꯒ (trapped sag) ꯑꯃꯗ ꯂꯩꯃꯥꯏꯒꯤ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯂꯩꯇꯦ꯫ |
| ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔ (clogging factor) | ꯏꯟꯂꯦꯠ ꯑꯃꯒꯤ ꯁꯦꯡꯂꯕ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯀꯦꯄꯥꯁꯤꯇꯤꯒꯤ ꯗꯦꯕ꯭ꯔꯤꯁꯅꯥ (debris) ꯃꯥꯡꯍꯜꯂꯤ ꯍꯥꯌꯅꯥ ꯂꯧꯕ ꯁꯔꯨꯛ (ꯀ꯭ꯂꯣꯖ 6.6.3)꯫ |
| ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯒ꯭ꯔꯦꯗ ꯂꯥꯏꯟ (HGL) | ꯀꯟꯗ꯭ꯌꯨꯏꯠ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯃꯗ ꯐ꯭ꯔꯤ-ꯁꯔꯐꯦꯁꯀꯤ ꯂꯦꯚꯦꯜꯁꯤꯡ, ꯅꯠꯔꯒꯥ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯗꯨ ꯄ꯭ꯔꯦꯁꯔꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯃꯐꯝꯗ ꯄꯥꯏꯖꯣꯃꯦꯇ꯭ꯔꯤꯛ ꯂꯦꯚꯦꯜꯁꯤꯡ, ꯁꯝꯅꯍꯟꯕ ꯂꯥꯏꯟ꯫ |
| ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟ (covered drain) | ꯃꯍꯧꯁꯥꯅꯥ ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯇ ꯂꯩꯕ, ꯐꯨꯠꯄꯥꯊ ꯑꯃꯥ ꯑꯣꯏꯍꯟꯕ ꯀꯥꯁ꯭ꯠ-ꯏꯟ-ꯁꯤꯇꯨ ꯅꯠꯔꯒꯥ ꯄ꯭ꯔꯤꯀꯥꯁ꯭ꯠ ꯀꯚꯔ ꯁ꯭ꯂꯦꯕꯁꯤꯡꯅꯥ ꯊꯤꯡꯂꯕ ꯃꯥꯏꯀꯩ ꯃꯔꯤ ꯂꯩꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ꯫ |
| ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁ (sediment allowance) | ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯄꯥꯏꯞ ꯑꯃꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯊꯤꯕꯥ ꯃꯇꯝꯗ ꯂꯩꯃꯨꯅꯥ ꯃꯄꯨꯟꯕ ꯑꯣꯏꯔꯦ ꯍꯥꯌꯅꯥ ꯂꯧꯕ ꯑꯏꯡꯕ ꯅꯠꯔꯒꯥ ꯑꯦꯔꯤꯌꯥ (ꯀ꯭ꯂꯣꯖ 6.7.8)꯫ |
| ꯆꯦꯛ ꯏꯚꯦꯟꯠ (check event) | ꯗꯤꯖꯥꯏꯟ AEP-ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯌꯥꯝꯗꯅꯥ ꯊꯣꯀꯄ AEP ꯑꯃꯥ, ꯃꯁꯤꯗ ꯃꯥꯏꯅꯔ ꯑꯃꯁꯨꯡ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯄꯨꯟꯅꯕꯅꯥ ꯍꯧꯖꯤꯛꯁꯨ ꯇꯦꯕꯜ 6.2-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ ꯌꯧꯒꯗꯕꯅꯤ꯫ |
| ꯍꯥꯏ-ꯗꯦꯟꯁꯤꯇꯤ ꯑꯦꯔꯤꯌꯥ (high-density area) | ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯀ꯭ꯂꯣꯖ 6.4.4-ꯒꯤ ꯃꯈꯥꯗ ꯃꯑꯣꯡ ꯑꯗꯨꯅꯥ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯑꯦꯔꯤꯌꯥ ꯑꯃꯥ꯫ |
| ꯀ꯭ꯂꯥꯁ I ꯑꯦꯔꯤꯌꯥ (Class I area) | ꯃꯤꯁꯤꯡ 1 ꯂꯥꯈ ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯂꯩꯕ ꯎꯔꯕꯟ ꯂꯣꯀꯜ ꯕꯣꯗꯤ ꯑꯃꯥ (CPHEEO-ꯒꯤ ꯑꯔꯊ)꯫ |
6.3 ꯗ꯭ꯌꯨꯑꯦꯜ ꯏꯔꯝꯒꯤ ꯋꯥꯈꯜꯂꯣꯟ
6.3.1 ꯏꯔꯝ ꯁꯤꯁ꯭ꯇꯦꯝ ꯈꯨꯗꯤꯡꯃꯛ ꯄꯨꯟꯅꯥ ꯊꯕꯛ ꯇꯧꯕ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯅꯤ ꯑꯣꯏꯅꯥ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ:
- (a) ꯇꯦꯕꯜ 6.1-ꯒꯤ ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯂꯩꯃꯥꯏꯒꯤ ꯃꯈꯥꯗ ꯅꯠꯔꯒꯥ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯄꯨꯗꯨꯅꯥ ꯂꯝꯕꯤꯁꯤꯡ ꯁꯤꯖꯤꯟꯅꯕ ꯌꯥꯕ ꯑꯃꯁꯨꯡ ꯁ꯭ꯞꯔꯦꯗ ꯑꯗꯨ ꯇꯦꯕꯜ 6.2-ꯒꯤ ꯃꯅꯨꯡꯗ ꯊꯝꯕ ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯃꯥ; ꯑꯃꯁꯨꯡ
- (b) ꯃꯥꯏꯅꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯐ꯭ꯂꯣ ꯄꯨꯝꯅꯃꯛ, 1% AEP (100-yr) ꯐ꯭ꯂꯣ ꯐꯥꯎꯕ, ꯂꯩꯃꯥꯏꯗ ꯕꯤꯜꯗꯤꯡꯁꯤꯡꯗ ꯆꯡꯗꯅꯥ ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 6.5-ꯒꯤ ꯑꯏꯡꯕ ꯑꯃꯁꯨꯡ ꯍꯖꯥꯔꯗꯀꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ ꯄꯨꯕ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯃꯥ꯫
6.3.2 ꯑꯦꯂꯤꯃꯦꯟꯠ ꯈꯨꯗꯤꯡꯃꯛꯇ 1%-ꯒꯤ ꯂꯝꯕꯤ ꯑꯃꯥ ꯂꯩ. ꯏꯟꯂꯦꯠ, ꯁꯦꯒ, ꯄꯥꯏꯞ, ꯈꯣꯡꯕꯥꯟ, ꯀꯜꯚꯔꯠ ꯑꯃꯁꯨꯡ ꯁ꯭ꯇꯣꯔꯦꯖ ꯑꯦꯂꯤꯃꯦꯟꯠ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯏꯁꯤꯡ ꯂꯧꯕ ꯋꯥꯇꯔꯋꯦ, ꯄꯨꯈ꯭ꯔꯤ ꯅꯠꯔꯒꯥ ꯑꯥꯎꯠꯐꯣꯜ ꯑꯃꯗ ꯆꯠꯄ, ꯃꯌꯦꯛ ꯁꯦꯡꯅꯥ ꯈꯡꯗꯣꯛꯂꯕ 1% AEP-ꯒꯤ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ꯫ ꯂꯝꯕꯤ ꯑꯗꯨ ꯏꯔꯝꯒꯤ ꯄ꯭ꯂꯥꯟꯗ (ꯀ꯭ꯂꯣꯖ 6.15) ꯎꯠꯀꯗꯕꯅꯤ꯫
6.3.3 ꯃꯦꯖꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣ. ꯃꯐꯝ ꯑꯃꯍꯦꯛꯇꯗ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯅꯥ 1% AEP-ꯒꯤ ꯄꯤꯛ ꯐ꯭ꯂꯣꯗꯒꯤ ꯃꯐꯝ ꯑꯗꯨꯒꯤ ꯃꯥꯏꯅꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯂꯧꯊꯣꯛꯈꯤꯕ ꯑꯗꯨ ꯄꯨꯒꯗꯕꯅꯤ꯫ ꯂꯧꯊꯣꯀꯄ ꯑꯁꯤꯗ ꯁꯤꯖꯤꯟꯅꯕ ꯃꯥꯏꯅꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯁꯤ ꯀ꯭ꯂꯣꯖ 6.6.3-ꯒꯤ ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔꯁꯤꯡ ꯂꯧꯔꯕ ꯃꯇꯨꯡꯒꯤ ꯏꯟꯂꯦꯠꯁꯤꯡꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ, ꯅꯠꯔꯒꯥ ꯄꯥꯏꯞꯀꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ, ꯃꯈꯣꯌꯒꯤ ꯃꯔꯛꯇ ꯑꯄꯤꯛꯄ ꯑꯗꯨꯅꯤ꯫ ꯁꯦꯒꯁꯤꯡꯗ ꯑꯃꯁꯨꯡ ꯕꯤꯜꯗꯤꯡꯒꯤ ꯐ꯭ꯂꯣꯔ ꯂꯦꯚꯦꯜ ꯊꯝꯅꯕ ꯁꯤꯖꯤꯟꯅꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯁꯤ ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯊꯤꯡꯂꯕ ꯐꯤꯚꯝꯗꯁꯨ ꯆꯦꯛ ꯇꯧꯒꯗꯕꯅꯤ (ꯀ꯭ꯂꯣꯖ 6.10.3)꯫
6.3.4 ꯅꯣꯡ ꯆꯨꯕ ꯑꯃꯁꯨꯡ ꯊꯧꯑꯣꯡ. ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯁꯤꯡꯅꯥ ꯁꯔꯨꯛ 2-ꯒꯤ ꯅꯣꯡ ꯆꯨꯕ (ꯀ꯭ꯂꯣꯖ 2.8-ꯒꯤ ꯀ꯭ꯂꯥꯏꯃꯦꯠ ꯐꯦꯛꯇꯔ ꯌꯥꯑꯣꯅꯥ) ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 3-ꯒꯤ ꯊꯧꯑꯣꯡꯁꯤꯡ ꯁꯤꯖꯤꯟꯅꯒꯗꯕꯅꯤ:
- (a) ꯔꯦꯁꯅꯦꯜ ꯃꯦꯊꯗ (Rational Method) ꯑꯁꯤ ≤ 16 ha-ꯒꯤ ꯀꯦꯆꯃꯦꯟꯠꯁꯤꯡ (catchment) ꯑꯃꯁꯨꯡ ꯀꯟꯚꯦꯌꯦꯟꯁ ꯑꯦꯂꯤꯃꯦꯟꯠ ꯑꯃꯈꯛꯇꯒꯤꯗꯃꯛ ꯈꯛꯇꯃꯛ꯫ ꯃꯁꯤ ꯃꯄꯨꯡ ꯐꯥꯕ ꯀꯦꯆꯃꯦꯟꯠ 16 ha-ꯗꯒꯤ ꯍꯦꯟꯕ ꯅꯦꯠꯋꯔꯛ ꯑꯃꯒꯤ ꯃꯈꯥ ꯊꯡꯅꯥ ꯐ꯭ꯂꯣꯁꯤꯡ ꯄꯨꯟꯁꯤꯟꯅꯕ ꯁꯤꯖꯤꯟꯅꯔꯣꯏꯗꯕꯅꯤ;
- (b) 16 ha-ꯗꯒꯤ ꯍꯦꯟꯕ ꯅꯦꯠꯋꯔꯛꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁ꯭ꯇꯣꯔꯦꯖ, ꯄꯝꯄꯤꯡ ꯅꯠꯔꯒꯥ ꯇꯥꯏꯗꯦꯜ ꯑꯥꯎꯠꯐꯣꯜ (tidal outfall) ꯂꯩꯕ ꯅꯦꯠꯋꯔꯛ ꯈꯨꯗꯤꯡꯃꯛꯀꯤꯗꯃꯛ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯔꯧꯇꯤꯡ (hydraulic routing) ꯂꯩꯕ ꯍꯥꯏꯗ꯭ꯔꯣꯒ꯭ꯔꯥꯐ (hydrograph) ꯊꯧꯑꯣꯡ ꯑꯃꯥ (ꯈꯨꯗꯝ ꯑꯣꯏꯅꯥ SWMM, ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯃꯣꯗꯦꯜ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ HEC-HMS, ꯅꯠꯔꯒꯥ ꯃꯁꯤꯒꯥ ꯃꯥꯟꯅꯕ 1D/2D ꯃꯣꯗꯦꯜ ꯑꯃꯥ);
- (c) ꯃꯤꯅꯤꯠ 10-ꯒꯤ ꯃꯤꯅꯤꯃꯝ ꯇꯥꯏꯝ ꯑꯣꯐ ꯀꯟꯁꯦꯟꯇ꯭ꯔꯦꯁꯟ (time of concentration)꯫
6.3.5 ꯀꯦꯆꯃꯦꯟꯠꯁꯤꯡꯒꯤ ꯃꯔꯛꯇ ꯐ꯭ꯂꯣ ꯍꯣꯡꯗꯣꯀꯄ ꯌꯥꯔꯣꯏ. ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯐꯠꯇꯕ ꯑꯍꯣꯡꯕ ꯑꯃꯠꯇꯥ ꯂꯩꯇꯦ ꯍꯥꯌꯅꯥ ꯎꯠꯄ ꯀꯦꯆꯃꯦꯟꯠ ꯄꯨꯝꯕꯒꯤ ꯁ꯭ꯇꯗꯤ ꯑꯃꯥ ꯌꯥꯗ꯭ꯔꯕꯗꯤ, ꯃꯥꯏꯅꯔ ꯅꯠꯔꯒꯥ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯃꯠꯇꯅꯥ ꯃꯍꯧꯁꯥꯒꯤ ꯀꯦꯆꯃꯦꯟꯠ ꯑꯃꯗꯒꯤ ꯑꯇꯣꯞꯄ ꯑꯃꯗ ꯐ꯭ꯂꯣ ꯂꯥꯟꯊꯣꯛꯂꯣꯏꯗꯕꯅꯤ꯫
6.3.6 ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ, ꯑꯃꯁꯨꯡ ꯆꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ. ꯏꯝꯐꯥꯜꯒꯤ ꯁꯤꯋꯔ (sewer) ꯂꯩꯕ ꯋꯥꯔꯗꯁꯤꯡꯒꯤ ꯃꯄꯥꯟꯗ, ꯃꯅꯤꯄꯨꯔꯗ ꯁꯥꯏꯠ ꯑꯃꯗꯒꯤ ꯅꯠꯔꯒꯥ ꯄꯕ꯭ꯂꯤꯛ ꯏꯔꯝ ꯄ꯭ꯔꯣꯖꯦꯛꯠ ꯑꯃꯗꯒꯤ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯂꯧꯕ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨꯅꯥ ꯃꯍꯧꯁꯥꯅꯥ ꯁꯦꯞꯇꯤꯛ ꯇꯦꯉ꯭ꯛꯁꯤꯡ, ꯁꯣꯛ ꯄꯤꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯀꯅꯦꯛꯁꯟꯁꯤꯡꯗꯒꯤ ꯁꯤꯋꯦꯖ ꯑꯃꯁꯨꯡ ꯌꯨꯝꯒꯤ ꯃꯣꯠꯄ ꯏꯁꯤꯡꯁꯨ (sullage) ꯄꯨꯏ (ꯀ꯭ꯂꯣꯖ 8.9); ꯑꯃꯁꯨꯡ ꯆꯤꯡꯁꯤꯡꯗ ꯑꯃꯁꯨꯡ ꯇꯝꯄꯥꯛꯀꯤ ꯃꯅꯥꯛꯇ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯅꯥ ꯂꯩꯃꯨ, ꯅꯨꯡꯀꯨꯞ, ꯂꯥꯟꯊꯔꯛꯄꯒꯤ ꯗꯦꯕ꯭ꯔꯤꯁ ꯑꯃꯁꯨꯡ ꯋꯦꯁ꯭ꯠꯁꯨ ꯄꯨꯏ꯫ ꯁꯔꯨꯛ ꯑꯁꯤ ꯀꯅꯦꯛꯁꯟ ꯇꯧꯕ ꯃꯐꯝ ꯐꯥꯎꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯃꯁꯨꯡ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯆꯠꯅꯩ, ꯃꯈꯥꯒꯤ ꯍꯥꯄꯆꯤꯅꯕꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ (ꯄꯨꯝꯅꯃꯛ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕ)꯫
ꯃꯤꯠꯌꯦꯡ (a)-ꯗꯒꯤ (e) ꯐꯥꯎꯕ ꯑꯁꯤ ꯏꯁꯤꯡ ꯂꯧꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨꯅꯥ ꯁꯤꯋꯦꯖ ꯅꯠꯔꯒꯥ ꯌꯨꯝꯒꯤ ꯃꯣꯠꯄ ꯏꯁꯤꯡꯒꯤ ꯅꯣꯡ ꯆꯨꯗꯕ ꯃꯇꯝꯒꯤ ꯆꯦꯟꯕ (DWF) ꯄꯨꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯆꯠꯅꯩ, ꯃꯁꯤꯒꯤ ꯃꯄꯨꯅꯥ ꯀꯔꯤ ꯀꯧꯔꯕꯁꯨ:
- (a) ꯁꯥꯏꯠꯇ ꯇꯣꯉꯥꯟꯅꯥ ꯊꯝꯕ. ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁꯤꯋꯦꯖ ꯑꯁꯤ ꯁꯥꯏꯠꯀꯤ ꯃꯅꯨꯡꯗ ꯇꯣꯉꯥꯟꯕ ꯁꯤꯁ꯭ꯇꯦꯝꯁꯤꯡꯗ ꯈꯣꯃꯖꯤꯟꯒꯗꯕꯅꯤ, ꯃꯈꯣꯌ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯁꯥꯏꯠꯀꯤ ꯉꯃꯈꯩꯗ ꯃꯁꯥꯒꯤ ꯑꯔꯣꯏꯕ ꯏꯟꯁ꯭ꯄꯦꯛꯁꯟ ꯆꯦꯝꯕꯔ (inspection chamber) ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯇꯣꯉꯥꯟꯕ ꯄꯕ꯭ꯂꯤꯛ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯁꯥꯒꯠꯂꯕ ꯃꯇꯝꯗ ꯅꯠꯔꯒꯥ ꯃꯐꯝ ꯑꯗꯨꯒꯤ ꯁꯤꯋꯔꯁꯤꯡ ꯀꯃꯤꯁꯟ ꯇꯧꯔꯕ ꯃꯇꯝꯗ ꯁꯥꯏꯠꯇ ꯑꯃꯨꯛ ꯍꯟꯅꯥ ꯊꯕꯛ ꯇꯧꯗꯅꯥ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯗꯨ ꯃꯗꯨꯗ ꯁꯝꯃꯤꯟꯅꯕ ꯌꯥꯒꯅꯤ꯫ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯏꯁꯤꯡ ꯂꯧꯕ ꯈꯣꯡꯕꯥꯟꯗ ꯀꯅꯦꯛꯁꯟ ꯑꯃꯈꯛꯇꯃꯛ ꯌꯥꯍꯜꯂꯕ ꯃꯐꯝꯗ, ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯅꯤ ꯑꯁꯤ ꯏꯟꯁ꯭ꯄꯦꯛꯁꯟ ꯆꯦꯝꯕꯔ ꯑꯅꯤꯃꯛꯀꯤ ꯃꯇꯨꯡꯗ ꯂꯩꯕ ꯑꯔꯣꯏꯕ ꯆꯦꯝꯕꯔ ꯑꯃꯗ ꯈꯛꯇꯃꯛ ꯁꯝꯅꯒꯗꯕꯅꯤ꯫ ꯃꯣꯗꯦꯜ ꯕꯥꯏ-ꯂꯣꯖꯅꯥ ꯃꯃꯥꯡꯗꯒꯤ ꯂꯝꯕꯤ ꯑꯁꯤꯗ ꯇꯥꯛꯂꯤ, ꯑꯃꯁꯨꯡ ꯃꯤꯠꯌꯦꯡ ꯑꯁꯤꯒꯤ ꯍꯨꯛꯁꯤꯡꯅꯤ: "ꯁꯣꯛ-ꯄꯤꯠꯇꯒꯤ ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯜ ꯈꯣꯡꯕꯥꯟꯗ ꯊꯣꯀꯄ ꯂꯝꯕꯤ ꯂꯩꯔꯕꯗꯤ, ꯃꯔꯛꯀꯤ ꯇ꯭ꯔꯤꯠꯃꯦꯟꯠ ꯆꯦꯝꯕꯔ ꯑꯃꯥ ꯊꯝꯕ ꯐꯩ" ("For outlet from the soak-pit to municipal drain if provided, an intermediate treatment chamber should be installed") (ꯕꯥꯏ-ꯂꯣ 6(1)(A)); ꯂꯦꯇ꯭ꯔꯤꯟ ꯑꯃꯥ "ꯁꯥꯏꯠꯇꯒꯤ 30 m … ꯒꯤ ꯃꯅꯨꯡꯗ ꯁꯤꯋꯔ ꯑꯃꯥ ꯂꯩꯔꯕꯗꯤ ꯀꯅꯦꯛꯠ ꯇꯧꯔꯕ ꯂꯦꯇ꯭ꯔꯤꯟ ꯑꯣꯏꯒꯗꯕꯅꯤ" ("shall be a connected latrine if a sewer is within 30 m … of the site") (ꯕꯥꯏ-ꯂꯣ 27); ꯑꯃꯁꯨꯡ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯄꯥꯏꯞ ꯑꯃꯅꯥ "ꯁꯣꯏꯜ ꯄꯥꯏꯞ ꯑꯃꯠꯇꯗ ꯊꯥꯗꯣꯛꯂꯣꯏꯗꯕꯅꯤ ꯅꯠꯔꯒꯥ ꯁꯝꯃꯤꯟꯅꯔꯣꯏꯗꯕꯅꯤ" ("shall not discharge into or connect with any soil pipe") ꯑꯃꯁꯨꯡ "ꯀꯔꯤꯒꯨꯝꯕ ꯐꯤꯚꯝ ꯑꯃꯗꯁꯨ ꯊꯤꯡꯂꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯠꯇꯗ ꯍꯛꯊꯦꯡꯅꯅ ꯊꯥꯗꯣꯛꯂꯣꯏꯗꯕꯅꯤ" ("in no case shall it discharge directly into any closed drain") (ꯕꯥꯏ-ꯂꯣ 28(v) ꯑꯃꯁꯨꯡ (ii)) [TBC: ꯂꯣꯀꯜ ꯕꯣꯗꯤꯅꯥ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯕꯥꯏ-ꯂꯣꯖꯇ ꯅꯝꯕꯔꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇꯦꯛꯁꯇ ꯆꯦꯛ ꯇꯧꯒꯗꯕꯅꯤ]꯫ ꯏꯝꯐꯥꯜ ꯁꯤꯋꯔꯦꯖ (sewerage) ꯄ꯭ꯔꯣꯖꯦꯛꯠꯀꯤ ꯋꯥꯔꯗꯁꯤꯡꯗ, ꯁꯥꯏꯠꯀꯤ ꯁꯤꯋꯦꯖ ꯑꯁꯤ ꯁꯤꯋꯔꯗ ꯆꯠꯏ ꯑꯃꯁꯨꯡ ꯃꯁꯤꯒꯤ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯑꯁꯤ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟꯗ ꯆꯠꯏ, ꯑꯃꯁꯨꯡ ꯑꯅꯤ ꯑꯁꯤ ꯁꯝꯃꯤꯟꯅꯔꯣꯏꯗꯕꯅꯤ꯫ ꯀ꯭ꯂꯣꯖ 6.13.7 ꯑꯁꯤ ꯁꯥꯏꯠꯀꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯆꯠꯅꯩ꯫
- (b) ꯄꯤꯛ ꯏꯟꯐ꯭ꯂꯣ ꯍꯦꯟꯒꯠꯍꯟꯗꯕ. ꯁꯔꯨꯛ 4 ꯆꯠꯅꯕ ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯑꯃꯅꯥ ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯈꯣꯡꯕꯥꯟꯗ ꯀꯅꯦꯛꯁꯟ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯑꯇꯣꯞꯄ ꯁꯥꯏꯠ ꯑꯥꯎꯠꯐꯣꯜ ꯑꯃꯍꯦꯛꯇꯗ ꯇꯧꯕꯒꯨꯝꯅꯥ, ꯁꯔꯨꯛ 4 ꯌꯧꯒꯗꯕꯅꯤ (ꯀ꯭ꯂꯣꯖ 4.5.1.3)꯫ ꯀ꯭ꯂꯣꯖ 1.5.2-ꯒꯤ ꯊ꯭ꯔꯦꯁꯍꯣꯜꯗꯁꯤꯡꯗꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯑꯃꯅꯥ ꯄꯤꯛ ꯏꯟꯐ꯭ꯂꯣ ꯑꯗꯨ ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠꯀꯤ ꯃꯃꯥꯡꯒꯤ ꯁꯥꯏꯠꯀꯤ ꯑꯗꯨꯗꯒꯤ ꯍꯦꯟꯒꯠꯍꯟꯂꯣꯏꯗꯕꯅꯤ: ꯃꯁꯤꯅꯥ ꯏꯝꯄꯔꯚꯤꯌꯁ ꯑꯦꯔꯤꯌꯥ (impervious area) ꯍꯥꯄꯆꯤꯜꯂꯕ ꯃꯐꯝꯗ, ꯍꯥꯄꯆꯤꯜꯂꯕ ꯑꯦꯔꯤꯌꯥꯒꯤ ꯌꯨꯝꯊꯛꯀꯤ ꯏꯁꯤꯡ ꯑꯁꯤ ꯀꯅꯦꯛꯁꯟ ꯑꯗꯨꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯀꯟꯇ꯭ꯔꯣꯜ ꯇꯧꯔꯕ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯂꯩꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯈꯣꯃꯖꯤꯟꯕꯒꯤ ꯅꯠꯔꯒꯥ ꯁ꯭ꯇꯣꯔꯦꯖꯒꯤ ꯇꯦꯉ꯭ꯛ ꯑꯃꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯆꯠꯀꯗꯕꯅꯤ꯫
- (c) ꯇꯦꯜꯋꯥꯇꯔ ꯑꯃꯁꯨꯡ ꯕꯦꯛꯐ꯭ꯂꯣ. ꯀ꯭ꯂꯣꯖ 6.8-ꯒꯤ HGL ꯑꯁꯤ ꯀꯣꯏꯟꯁꯤꯗꯦꯟꯠ ꯏꯚꯦꯟꯠꯇ (coincident event) ꯀꯅꯦꯛꯁꯟ ꯇꯧꯕ ꯃꯐꯝꯗ ꯏꯁꯤꯡ ꯂꯧꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯍꯧꯒꯗꯕꯅꯤ, ꯃꯄꯨꯒꯤ ꯃꯣꯗꯦꯜ ꯂꯩꯔꯕꯗꯤ ꯃꯗꯨꯗꯒꯤ ꯂꯧꯒꯗꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯂꯩꯇꯕꯗꯤ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯑꯣꯕꯚꯔꯠ (obvert) ꯅꯠꯔꯒꯥ ꯂꯩꯔꯥꯏꯒꯤ ꯃꯊꯛꯇ ꯂꯧꯒꯗꯕꯅꯤ (ꯀ꯭ꯂꯣꯖ 5.6.2)꯫ ꯏꯁꯤꯡ ꯂꯧꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨ ꯄꯟꯅꯥ ꯂꯣꯛ ꯇꯧꯕ ꯅꯠꯔꯒꯥ ꯄꯝꯞꯅꯥ ꯊꯥꯗꯣꯀꯄ ꯑꯥꯎꯠꯐꯣꯜ ꯑꯃꯗ, ꯅꯠꯔꯒꯥ ꯂꯣꯛꯇꯥꯛꯇ ꯂꯣꯏꯔꯕ ꯃꯐꯝꯗ, ꯀ꯭ꯂꯣꯖ 5.10-ꯒꯤ ꯑꯥꯎꯠꯐꯣꯜ ꯊꯤꯡꯕ ꯆꯦꯛ ꯑꯁꯤ ꯀ꯭ꯂꯣꯖ 5.8.5(a)-ꯒꯤ ꯂꯣꯛ (lock) ꯅꯠꯔꯒꯥ ꯀ꯭ꯂꯣꯖ 5.8.5(c)-ꯒꯤ ꯊꯤꯡꯕꯒꯥ ꯂꯣꯌꯅꯅ ꯆꯠꯅꯩ꯫ ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯂꯩꯕ ꯀꯅꯦꯛꯁꯟ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯑꯣꯏꯔꯕꯁꯨ ꯁꯤꯋꯦꯖꯒꯤ ꯑꯣꯏꯔꯕꯁꯨ, ꯃꯁꯤꯅꯥ ꯁꯦꯕꯥ ꯄꯤꯕ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯅꯦꯝꯕ ꯏꯔꯝꯒꯤ ꯐꯤꯇꯤꯡ ꯅꯠꯔꯒꯥ ꯍꯥꯡꯕ ꯃꯐꯝ ꯑꯗꯨ ꯀꯅꯦꯛꯁꯟ ꯇꯧꯕ ꯃꯐꯝꯗ ꯏꯁꯤꯡ ꯂꯧꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯀꯚꯔ ꯅꯠꯔꯒꯥ ꯂꯩꯔꯥꯏꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯔꯕꯗꯤ, ꯅꯟ-ꯔꯤꯇꯔꯟ ꯚꯥꯜꯚ (non-return valve) ꯑꯃꯥ (ꯀ꯭ꯂꯣꯖ 6.8.8) ꯊꯝꯒꯗꯕꯅꯤ꯫
- (d) ꯀꯦꯄꯥꯁꯤꯇꯤ, ꯚꯦꯂꯣꯁꯤꯇꯤ, ꯆꯡꯂꯛꯄꯒꯤ ꯂꯝꯕꯤ ꯑꯃꯁꯨꯡ ꯃꯅꯝ. ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯃꯁꯤꯒꯤ ꯃꯐꯝꯒꯤ ꯁꯤꯋꯔꯁꯤꯡ ꯁꯝꯃꯤꯟꯅꯗ꯭ꯔꯤꯐꯥꯎꯕ ꯀꯝꯕꯥꯏꯟꯗ ꯆꯦꯅꯦꯜ (combined channel) ꯑꯃꯥ ꯑꯣꯏꯅꯥ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ: ꯀ꯭ꯂꯣꯖ 6.3.3-ꯗ ꯁꯤꯖꯤꯟꯅꯔꯤꯕ ꯃꯁꯤꯒꯤ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯁꯤ, ꯁꯦꯕꯥ ꯄꯤꯕ ꯃꯤꯁꯤꯡꯗꯒꯤ ꯊꯥꯖꯕ ꯅꯠꯔꯒꯥ ꯑꯦꯁ꯭ꯇꯤꯃꯦꯠ ꯇꯧꯔꯕ, ꯃꯁꯤꯒꯤ ꯅꯣꯡ ꯆꯨꯗꯕ ꯃꯇꯝꯒꯤ ꯆꯦꯟꯕ ꯂꯧꯊꯣꯛꯈꯤꯕ ꯃꯇꯨꯡꯗ ꯂꯦꯃꯍꯧꯔꯤꯕ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯗꯨ ꯑꯣꯏꯒꯗꯕꯅꯤ; ꯃꯁꯤꯅꯥ ꯃꯁꯤꯒꯤ ꯅꯣꯡ ꯆꯨꯗꯕ ꯃꯇꯝꯒꯤ ꯆꯦꯟꯕꯗ ꯀ꯭ꯂꯣꯖ 6.7.3(a)-ꯒꯤ ꯃꯤꯅꯤꯃꯝ ꯚꯦꯂꯣꯁꯤꯇꯤ ꯌꯧꯒꯗꯕꯅꯤ, ꯅꯠꯔꯒꯥ ꯃꯗꯨ ꯌꯧꯕ ꯂꯣ-ꯐ꯭ꯂꯣ ꯆꯦꯅꯦꯜ (low-flow channel) ꯑꯃꯥ ꯃꯁꯤꯒꯤ ꯏꯟꯚꯔꯠꯇ (invert) ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯅꯣꯡ ꯆꯨꯕꯒꯤ ꯊꯧꯗꯣꯛꯁꯤꯡꯒꯤ ꯃꯔꯛꯇ ꯁꯤꯋꯦꯖꯒꯤ ꯁꯣꯂꯤꯗꯁꯤꯡ ꯊꯨꯗꯣꯛꯂꯣꯏ; ꯃꯁꯤ ꯀꯚꯔ ꯇꯧꯔꯕ ꯃꯐꯝꯗ, ꯃꯁꯤꯗ ꯀ꯭ꯂꯣꯖ 6.13.2-ꯒꯤ ꯆꯡꯂꯛꯅꯕ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡ ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯅꯝ ꯑꯁꯤ ꯌꯨꯝꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯐꯨꯠꯄꯥꯊꯁꯤꯡꯗ ꯌꯧꯗꯅꯕ ꯀꯚꯔꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯚꯦꯟꯇꯁꯤꯡ (vent) ꯊꯝꯒꯗꯕꯅꯤ; ꯑꯃꯁꯨꯡ ꯀꯅꯥꯒꯨꯝꯕ ꯑꯃꯠꯇꯅꯥ ꯃꯅꯨꯡꯗ ꯆꯡꯗꯅꯥ ꯍꯥꯡꯕ ꯃꯐꯝ ꯑꯗꯨꯁꯤꯡꯗꯒꯤ ꯃꯦꯁꯤꯅꯅꯥ ꯁꯦꯡꯗꯣꯛꯄ ꯌꯥꯒꯗꯕꯅꯤ꯫ ꯃꯁꯤꯒꯤ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤꯗꯒꯤ, ꯅꯠꯔꯒꯥ ꯏꯟꯂꯦꯠꯁꯤꯡꯅꯥ ꯆꯡꯍꯟꯕꯗꯒꯤ ꯍꯦꯟꯕ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯅꯥ ꯂꯩꯃꯥꯏꯗ ꯄꯨꯒꯗꯕꯅꯤ (ꯀ꯭ꯂꯣꯖ 6.3.2 ꯑꯃꯁꯨꯡ 6.9), ꯑꯃꯁꯨꯡ ꯐ꯭ꯂꯣꯔ ꯂꯦꯚꯦꯜꯁꯤꯡ ꯑꯁꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨ ꯁꯔꯆꯥꯔꯖ ꯑꯣꯏꯔꯕ ꯐꯤꯚꯝꯗ ꯀ꯭ꯂꯣꯖ 6.11-ꯒꯤ ꯃꯈꯥꯗ ꯊꯝꯒꯗꯕꯅꯤ꯫
- (e) ꯑꯥꯎꯠꯐꯣꯜꯁꯤꯡꯒꯤ ꯃꯃꯥꯡꯗ ꯏꯟꯇꯔꯁꯦꯞꯁꯟ ꯑꯃꯁꯨꯡ ꯁ꯭ꯀ꯭ꯔꯤꯟꯁꯤꯡ; ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯄ꯭ꯂꯥꯟ ꯇꯧꯕ ꯇꯣꯉꯥꯟꯅꯥ ꯊꯝꯕ. ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯄꯥꯠ ꯑꯃꯗ, ꯄꯨꯈ꯭ꯔꯤ ꯑꯃꯗ, ꯂꯣꯛꯇꯥꯛꯇ ꯅꯠꯔꯒꯥ CPCB-ꯒꯤ ꯄꯣꯂꯨꯠ ꯑꯣꯏꯕ ꯇꯨꯔꯦꯜ ꯁꯔꯨꯛꯁꯤꯡꯒꯤ ꯂꯤꯁ꯭ꯠꯇ ꯂꯩꯕ ꯇꯨꯔꯦꯜꯒꯤ ꯔꯤꯆ ꯑꯃꯗ (ꯃꯈꯣꯌꯒꯤ ꯃꯔꯛꯇ ꯁꯤꯡꯗꯥ ꯗꯦꯝꯗꯒꯤ ꯕꯤꯁ꯭ꯅꯨꯄꯨꯔ ꯐꯥꯎꯕ ꯅꯝꯕꯨꯜ ꯇꯨꯔꯦꯜ) ꯂꯩꯕ ꯃꯁꯤꯒꯤ ꯑꯥꯎꯠꯐꯣꯜꯒꯤ ꯃꯃꯥꯡꯗ ꯅꯣꯡ ꯆꯨꯗꯕ ꯃꯇꯝꯒꯤ ꯆꯦꯟꯕꯒꯤ ꯏꯟꯇꯔꯁꯦꯞꯁꯟ (interception) ꯑꯃꯁꯨꯡ ꯁ꯭ꯀ꯭ꯔꯤꯟ (screen) ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯁꯤ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯍꯟꯊꯍꯟꯗꯅꯕ ꯀ꯭ꯂꯣꯖ 8.9-ꯒꯤ ꯃꯈꯥꯗ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯇ꯭ꯔꯤꯠꯃꯦꯟꯠ ꯑꯗꯨ ꯌꯥꯎꯗꯅꯥ ꯑꯅꯧꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯠꯇꯥ ꯄꯥꯠ ꯑꯃꯗ ꯄꯨꯔꯛꯂꯣꯏꯗꯕꯅꯤ; ꯂꯝꯐꯦꯜꯄꯥꯠ ꯑꯍꯥꯅꯕꯗ ꯂꯥꯛꯀꯅꯤ, ꯃꯔꯝꯗꯤ ꯃꯁꯤ ꯁꯍꯔ ꯑꯁꯤꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯁ꯭ꯇꯣꯔꯦꯖ ꯑꯃꯁꯨꯡ ꯊꯛꯅꯕ ꯏꯁꯤꯡꯒꯤ ꯄ꯭ꯔꯄꯣꯖ ꯇꯧꯔꯕ ꯍꯧꯔꯛꯐꯝ ꯑꯅꯤꯃꯛ ꯑꯣꯏꯔꯤ꯫ ꯃꯅꯤꯄꯨꯔ ꯂꯣꯛꯇꯥꯛ ꯂꯦꯛ (ꯄ꯭ꯔꯣꯇꯦꯛꯁꯟ) ꯑꯦꯛꯠ, 2006-ꯒꯤ (Manipur Loktak Lake (Protection) Act, 2006) 236.21 km²-ꯒꯤ ꯃꯅꯨꯡꯗ "ꯏꯟꯗꯁ꯭ꯇ꯭ꯔꯤꯁꯤꯡ, ꯁꯍꯔꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯇꯥꯎꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯃꯤꯑꯣꯏꯕꯒꯤ ꯂꯩꯐꯝꯁꯤꯡꯗꯒꯤ ꯇ꯭ꯔꯤꯠ ꯇꯧꯗꯕ ꯋꯦꯁ꯭ꯠ ꯑꯃꯁꯨꯡ ꯏꯐ꯭ꯂꯨꯌꯦꯟꯠꯁꯤꯡ ꯊꯥꯗꯣꯀꯄ" ("Discharge of untreated wastes and effluents from industries, cities or towns and other human settlements") ꯑꯁꯤ ꯕꯐꯔ ꯖꯣꯟꯗ (Buffer Zone) ꯃꯃꯥꯡꯗꯒꯤ ꯊꯤꯡꯂꯦ (ꯁꯦꯛꯁꯟ 19(iv)), ꯑꯃꯁꯨꯡ ꯀꯣꯔ ꯖꯣꯟꯗ (Core Zone) "ꯑꯣꯊꯣꯔꯤꯇꯤꯒꯤ ꯃꯃꯥꯡꯒꯤ ꯑꯌꯥꯕ ꯂꯧꯗꯅꯥ" ("except with the prior permission of the authority") ꯁꯤꯋꯦꯖ ꯅꯠꯔꯒꯥ ꯌꯨꯝꯒꯤ ꯋꯦꯁ꯭ꯠ ꯑꯃꯠꯇꯥ ꯊꯥꯗꯣꯛꯄ ꯌꯥꯗꯦ (ꯁꯦꯛꯁꯟ 20(i))꯫ ꯑꯁꯤꯒꯨꯝꯕ ꯁ꯭ꯀ꯭ꯔꯤꯟ ꯈꯨꯗꯤꯡꯃꯛꯅꯥ ꯐꯨꯝꯗꯤ (phumdi) ꯑꯃꯁꯨꯡ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡꯅꯥ ꯄꯨꯔꯀꯄ ꯁꯣꯂꯤꯗ ꯋꯦꯁ꯭ꯠꯁꯨ ꯊꯤꯡꯒꯗꯕꯅꯤ, ꯃꯦꯁꯤꯅꯒꯤ ꯆꯡꯂꯛꯄꯒꯤ ꯂꯝꯕꯤ ꯑꯃꯁꯨꯡ ꯃꯁꯤꯅꯥ ꯐꯥꯕ ꯄꯣꯠꯁꯤꯡ ꯏꯁꯤꯡꯗꯒꯤ ꯂꯥꯞꯅꯥ ꯄꯨꯟꯁꯤꯟꯅꯕ ꯃꯐꯝ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ꯫ ꯇ꯭ꯔꯤꯠꯃꯦꯟꯠ ꯌꯥꯎꯗꯅꯥ ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯠꯇꯥ ꯂꯧꯒꯤ ꯆꯦꯅꯦꯜ ꯑꯃꯗ ꯅꯠꯔꯒꯥ "ꯂꯧꯉꯥꯡꯒꯤ ꯀꯦꯅꯦꯜ" ("agriculture canal") ꯑꯃꯗ ꯄꯨꯔꯛꯂꯣꯏꯗꯕꯅꯤ꯫ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯃꯁꯤꯒꯤ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯗ (ꯁꯔꯨꯛ 11) ꯇꯣꯉꯥꯟꯕ ꯄꯕ꯭ꯂꯤꯛ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯁꯥꯕ ꯌꯥꯕ ꯃꯐꯝꯁꯤꯡ, ꯃꯈꯣꯌꯒꯤ ꯃꯔꯛꯇ ꯏꯝꯐꯥꯜ ꯁꯤꯋꯔꯦꯖ ꯄ꯭ꯔꯣꯖꯦꯛꯠꯀꯤ ꯋꯥꯔꯗꯁꯤꯡ ꯁꯝꯃꯤꯟꯅꯔꯀꯄꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ, ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯃꯐꯝꯁꯤꯡꯗ ꯀꯝꯕꯥꯏꯟꯗ ꯄꯤꯛ ꯊꯤꯡꯒꯅꯤꯕ ꯁ꯭ꯇꯣꯔꯦꯖ ꯑꯗꯨ ꯈꯡꯗꯣꯛꯀꯗꯕꯅꯤ; ꯆꯤꯡꯒꯤ ꯁꯍꯔ ꯑꯃꯗ, ꯂꯩꯐꯝ ꯑꯃꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯈꯨꯗꯤꯡꯃꯛ ꯁꯤꯋꯔꯁꯤꯡ ꯂꯩꯔꯛꯠꯔꯤꯐꯥꯎꯕ ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯣꯏꯅꯥ ꯂꯧꯒꯗꯕꯅꯤ; ꯑꯃꯁꯨꯡ ꯁꯥꯏꯠꯀꯤ ꯉꯃꯈꯩꯗ ꯇꯣꯉꯥꯟꯕ ꯄꯕ꯭ꯂꯤꯛ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯂꯩꯔꯕ ꯃꯐꯝꯗ, ꯁꯥꯏꯠꯀꯤ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯁꯤ ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯈꯣꯡꯕꯥꯟꯗ ꯅꯠꯇꯅꯥ ꯃꯗꯨꯗ ꯁꯝꯃꯤꯟꯅꯒꯗꯕꯅꯤ꯫ ꯀꯟꯚꯦꯌꯦꯟꯁ ꯗꯤꯖꯥꯏꯟ ꯔꯤꯄꯣꯔꯠ (ꯐꯣꯔꯝ 6-1) ꯑꯁꯤꯅꯥ ꯏꯁꯤꯡ ꯂꯧꯕ ꯈꯣꯡꯕꯥꯟ ꯈꯨꯗꯤꯡꯃꯛꯅꯥ ꯁꯤꯋꯦꯖ ꯄꯨꯕꯔꯥ, ꯏꯟꯐꯣꯔꯃꯦꯁꯟ ꯑꯗꯨꯒꯤ ꯍꯧꯔꯛꯐꯝ, ꯑꯃꯁꯨꯡ ꯃꯤꯠꯌꯦꯡ (a)-ꯗꯒꯤ (e) ꯐꯥꯎꯕ ꯀꯔꯝꯅꯥ ꯌꯧꯍꯜꯂꯤꯕꯒꯦ ꯍꯥꯌꯕꯗꯨ ꯐꯣꯡꯗꯣꯛꯀꯗꯕꯅꯤ꯫
ꯃꯤꯠꯌꯦꯡ (f)-ꯗꯒꯤ (m) ꯐꯥꯎꯕ ꯑꯁꯤ ꯆꯤꯡꯒꯤ ꯀꯦꯆꯃꯦꯟꯠ ꯑꯃꯗꯒꯤ ꯔꯟꯑꯣꯐ ꯂꯧꯕ ꯃꯥꯏꯅꯔ ꯑꯃꯁꯨꯡ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯁꯤꯡꯒꯤ ꯑꯦꯂꯤꯃꯦꯟꯠ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯆꯠꯅꯩ, ꯃꯁꯤꯒꯤ ꯑꯔꯊꯗꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯗ ꯑꯍꯦꯟꯕ 2A-ꯒꯤ ꯁꯕ-ꯑꯦꯔꯤꯌꯥ MN-B ꯑꯃꯁꯨꯡ MN-C-ꯗ ꯂꯩꯕ ꯂꯝ, MN-C1-ꯒꯤ ꯆꯤꯡꯒꯤ ꯁꯔꯨꯛꯁꯤꯡ, MN-A-ꯗ ꯂꯩꯕ ꯇꯝꯄꯥꯛꯀꯤ ꯃꯅꯥꯛꯀꯤ ꯅꯥꯄꯣꯝꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇꯝꯄꯥꯛꯀꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯕ ꯆꯤꯡ ꯑꯄꯤꯛꯁꯤꯡ, ꯃꯍꯧꯁꯥꯒꯤ ꯂꯩꯃꯥꯏ ꯑꯦꯕꯔꯦꯖ ꯑꯣꯏꯅꯥ 10%-ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯅꯥꯄꯣꯝ ꯂꯩꯕ ꯀꯦꯆꯃꯦꯟꯠ ꯈꯨꯗꯤꯡꯃꯛ, ꯑꯃꯁꯨꯡ ꯆꯤꯡꯁꯤꯡꯗꯒꯤ ꯂꯥꯀꯄ ꯈꯣꯡ ꯅꯠꯔꯒꯥ ꯑꯇꯣꯞꯄ ꯁ꯭ꯇ꯭ꯔꯤꯝ ꯈꯨꯗꯤꯡꯃꯛ, ꯇꯝꯄꯥꯛꯀꯤ ꯂꯝ ꯑꯃꯁꯨꯡ ꯂꯣꯛꯇꯥꯛꯇ ꯌꯧꯕꯁꯤꯡ ꯌꯥꯑꯣꯅꯥ:
- (f) ꯗꯦꯕ꯭ꯔꯤꯁ ꯔꯦꯛꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇ꯭ꯔꯦꯞꯁꯤꯡ. ꯁꯥꯒꯠꯇꯕ ꯆꯤꯡꯒꯤ ꯂꯝ (ꯎꯃꯡ, ꯎꯄꯥꯜ, ꯖꯨꯝ ꯅꯠꯔꯒꯥ ꯑꯇꯣꯞꯄ ꯂꯧꯉꯥꯡ ꯇꯧꯕ ꯅꯥꯄꯣꯝ, ꯍꯥꯡꯕ ꯅꯥꯄꯣꯝ, ꯀ꯭ꯋꯥꯔꯤ ꯅꯠꯔꯒꯥ ꯀꯠ ꯁ꯭ꯂꯣꯞ) 1 ha ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕꯗꯒꯤ, ꯅꯠꯔꯒꯥ ꯀꯦꯆꯃꯦꯟꯠ ꯀꯌꯥ ꯆꯥꯎꯔꯕꯁꯨ ꯈꯣꯡ ꯅꯠꯔꯒꯥ ꯑꯇꯣꯞꯄ ꯆꯤꯡꯒꯤ ꯈꯣꯡ ꯑꯃꯗꯒꯤ ꯐ꯭ꯂꯣ ꯂꯧꯕ ꯏꯟꯂꯦꯠ, ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯄꯥꯏꯞꯀꯤ ꯆꯡꯐꯝ ꯑꯃꯁꯨꯡ ꯀꯜꯚꯔꯠ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯊꯛ ꯊꯡꯕ ꯃꯐꯝꯗ ꯗꯦꯕ꯭ꯔꯤꯁ ꯔꯦꯛ (debris rack) ꯅꯠꯔꯒꯥ ꯗꯦꯕ꯭ꯔꯤꯁ ꯇ꯭ꯔꯦꯞ (debris trap) ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯁꯤ ꯁꯔꯨꯛ 9 (ꯀ꯭ꯂꯣꯖ 9.8)-ꯒꯤ ꯃꯈꯥꯗ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ, ꯃꯦꯁꯤꯅꯒꯤ ꯆꯡꯂꯛꯄꯒꯤ ꯂꯝꯕꯤ ꯑꯃꯁꯨꯡ ꯃꯁꯤꯅꯥ ꯐꯥꯕ ꯄꯣꯠꯁꯤꯡ ꯄꯨꯟꯁꯤꯟꯅꯕ ꯆꯦꯠꯄ ꯃꯐꯝ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ, ꯃꯐꯝ ꯑꯗꯨ ꯅꯥꯄꯣꯝ, ꯈꯣꯡ, ꯄꯥꯠ ꯑꯃꯒꯤ ꯃꯄꯥꯟ ꯅꯠꯔꯒꯥ ꯂꯧꯕꯨꯛ ꯑꯣꯏꯔꯣꯏꯗꯕꯅꯤ꯫ ꯔꯦꯛ ꯑꯗꯨꯒꯤ 50% ꯊꯤꯡꯂꯕꯁꯨ, ꯃꯁꯤꯅꯥ ꯉꯥꯛꯊꯣꯀꯄ ꯑꯦꯂꯤꯃꯦꯟꯠ ꯑꯗꯨꯅꯥ ꯍꯧꯖꯤꯛꯁꯨ ꯃꯁꯤꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣ ꯆꯠꯍꯅꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯑꯗꯨꯅꯥ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯗ ꯅꯠꯔꯒꯥ ꯉꯥꯛꯊꯣꯛꯇꯕ ꯅꯥꯄꯣꯝ ꯑꯃꯗ ꯊꯥꯔꯣꯏꯗꯕꯅꯤ꯫ ꯔꯦꯛꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇ꯭ꯔꯦꯞꯁꯤꯡ ꯑꯁꯤ 31 ꯃꯥꯔꯆꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ, ꯑꯦꯞꯔꯤꯜ–ꯃꯦꯒꯤ ꯅꯣꯡ ꯆꯨꯕꯒꯤ ꯊꯧꯗꯣꯛꯁꯤꯡꯒꯤ ꯃꯇꯨꯡꯗ 15 ꯃꯦꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯑꯃꯨꯛ ꯍꯟꯅꯥ, ꯑꯃꯁꯨꯡ ꯃꯇꯝ ꯑꯗꯨꯒꯤ ꯃꯇꯨꯡꯗ 15 ꯅꯣꯚꯦꯝꯕꯔꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯁꯦꯡꯗꯣꯛꯀꯗꯕꯅꯤ (ꯁꯔꯨꯛ 10)꯫ ꯗꯦꯕ꯭ꯔꯤꯁ ꯕꯦꯁꯤꯟ (debris basin) ꯑꯃꯒꯤ ꯚꯣꯂꯨꯝ ꯑꯁꯤ ꯁꯔꯨꯛ 9-ꯗ ꯊꯝꯒꯗꯕꯅꯤ [TBC]꯫
- (g) ꯕꯜꯀꯤꯡ ꯐꯦꯛꯇꯔ (bulking factor). ꯆꯤꯡꯒꯤ ꯀꯦꯆꯃꯦꯟꯠ ꯑꯃꯗꯒꯤ ꯐ꯭ꯂꯣ ꯂꯧꯕ ꯆꯦꯅꯦꯜ, ꯈꯣꯡꯕꯥꯟ, ꯄꯥꯏꯞ, ꯀꯜꯚꯔꯠ ꯑꯃꯁꯨꯡ ꯀ꯭ꯔꯣꯁꯤꯡ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣ, ꯆꯦꯛ ꯏꯚꯦꯟꯠ ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯐ꯭ꯂꯣꯒꯤꯗꯃꯛ, ꯁꯔꯨꯛ 3-ꯒꯤ ꯁꯦꯡꯂꯕ ꯏꯁꯤꯡꯒꯤ ꯄꯤꯛ ꯐ꯭ꯂꯣꯕꯨ 1.25-ꯒꯤ ꯕꯜꯀꯤꯡ ꯐꯦꯛꯇꯔꯅꯥ ꯃꯅꯥꯎꯕ ꯑꯗꯨ ꯑꯣꯏꯒꯗꯕꯅꯤ; ꯑꯇꯣꯞꯄ ꯃꯐꯝꯁꯤꯡꯗ ꯐꯦꯛꯇꯔ ꯑꯁꯤ 1.0-ꯅꯤ꯫ ꯐꯦꯛꯇꯔ ꯑꯁꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ, ꯐ꯭ꯔꯤꯕꯣꯔꯗ (freeboard) ꯑꯃꯁꯨꯡ ꯚꯦꯂꯣꯁꯤꯇꯤꯗ ꯆꯠꯅꯩ; ꯁ꯭ꯇꯣꯔꯦꯖꯒꯤꯗꯃꯛ ꯁꯤꯖꯤꯟꯅꯕ ꯔꯟꯑꯣꯐꯀꯤ ꯚꯣꯂꯨꯝꯗ (ꯁꯔꯨꯛ 4) ꯆꯠꯅꯗꯦ꯫ ꯀꯦꯆꯃꯦꯟꯠ ꯑꯗꯨꯒꯤ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯁ꯭ꯇꯗꯤ ꯑꯃꯅꯥ ꯍꯦꯟꯅꯥ ꯆꯥꯎꯕ ꯐꯦꯛꯇꯔ ꯑꯃꯥ ꯄꯤꯔꯕ ꯃꯐꯝꯗ ꯃꯗꯨ ꯁꯤꯖꯤꯟꯅꯒꯗꯕꯅꯤ꯫ ꯀ꯭ꯂꯣꯖ 2.3.6(i)-ꯒꯤ ꯁ꯭ꯀ꯭ꯔꯤꯅꯤꯡꯅꯥ ꯗꯦꯕ꯭ꯔꯤꯁ ꯐ꯭ꯂꯣ (debris flow) ꯅꯠꯔꯒꯥ ꯂꯦꯟꯗꯁ꯭ꯂꯥꯏꯗ (landslide) ꯊꯣꯀꯄ ꯌꯥꯕ ꯍꯥꯌꯅꯥ ꯎꯠꯄ ꯀꯦꯆꯃꯦꯟꯠ ꯑꯃꯥ, ꯅꯠꯔꯒꯥ ꯃꯦꯞ ꯇꯧꯔꯕ ꯂꯥꯟꯊꯔꯛꯄ, ꯐꯦꯟ (fan) ꯅꯠꯔꯒꯥ ꯆꯦꯅꯦꯜ ꯍꯣꯡꯕꯒꯤ ꯂꯝꯕꯤ ꯑꯃꯗꯒꯤ ꯏꯁꯤꯡ ꯂꯧꯕ ꯀꯦꯆꯃꯦꯟꯠ ꯑꯃꯥ ꯕꯜꯀꯤꯡ ꯐꯦꯛꯇꯔꯅꯥ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯗꯦ: ꯂꯝꯕꯤ ꯑꯗꯨꯗ ꯕꯤꯜꯗꯤꯡ, ꯑꯥꯎꯠꯐꯣꯜ, ꯄꯝꯄꯤꯡ ꯁ꯭ꯇꯦꯁꯟ ꯅꯠꯔꯒꯥ ꯁ꯭ꯇꯣꯔꯦꯖ ꯑꯃꯠꯇꯥ ꯊꯝꯂꯣꯏꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯕꯜꯀꯤꯡ ꯇꯧꯔꯕ ꯐ꯭ꯂꯣꯒꯤꯗꯃꯛ ꯈꯛꯇꯃꯛ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯏ [TBC]꯫
- (h) ꯕ꯭ꯂꯣꯀꯦꯖ (blockage). ꯀ꯭ꯂꯣꯖ 6.12.4-ꯒꯤ ꯕ꯭ꯂꯣꯀꯦꯖꯒꯤ ꯆꯦꯛ ꯑꯁꯤꯅꯥ ꯁ꯭ꯄꯦꯟ ꯅꯠꯔꯒꯥ ꯗꯥꯏꯃꯤꯇꯔ 3.0 m-ꯗꯒꯤ ꯍꯟꯊꯕ ꯀꯜꯚꯔꯠ ꯑꯃꯁꯨꯡ ꯄꯥꯏꯞꯀꯤ ꯆꯡꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯀꯤꯗꯃꯛ ꯏꯟꯂꯦꯠ ꯑꯦꯔꯤꯌꯥꯒꯤ 50% ꯊꯤꯡꯂꯦ ꯍꯥꯌꯅꯥ ꯂꯧꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯆꯥꯎꯕꯁꯤꯡꯒꯤꯗꯃꯛ 20%, ꯗꯦꯕ꯭ꯔꯤꯁ ꯔꯦꯛ ꯄꯤꯔꯕꯁꯨ ꯄꯤꯗꯕꯁꯨ꯫ ꯒ꯭ꯔꯦꯠ ꯏꯟꯂꯦꯠꯁꯤꯡꯅꯥ (grate inlet) ꯇꯦꯕꯜ 6.5-ꯒꯤ ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔ ꯊꯝꯃꯤ, ꯑꯃꯁꯨꯡ ꯒ꯭ꯔꯦꯗꯇ ꯂꯩꯕ ꯀꯔꯕ ꯑꯣꯄꯅꯤꯡꯁꯤꯡꯅꯥ (kerb opening) 20%-ꯒꯤ ꯁꯦꯒ ꯚꯦꯜꯌꯨ ꯂꯧꯏ꯫
- (i) ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯃꯁꯨꯡ ꯃꯤꯅꯤꯃꯝ ꯚꯦꯂꯣꯁꯤꯇꯤ. ꯆꯤꯡꯒꯤ ꯀꯦꯆꯃꯦꯟꯠ ꯑꯃꯗꯒꯤ ꯐ꯭ꯂꯣ ꯂꯧꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯁꯨꯡ ꯄꯥꯏꯞꯁꯤꯡꯅꯥ ꯀ꯭ꯂꯣꯖ 6.7.3(a)-ꯒꯤ ꯃꯤꯅꯤꯃꯝꯒꯤ ꯃꯍꯨꯠꯇ, ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯗ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 1.0 m/s-ꯒꯤ ꯚꯦꯂꯣꯁꯤꯇꯤ ꯌꯧꯒꯗꯕꯅꯤ꯫ ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠꯅꯥ ꯃꯁꯤ ꯌꯥꯍꯟꯗꯕ ꯃꯐꯝꯗ, ꯃꯊꯛ ꯊꯡꯕ ꯃꯐꯝꯗ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯇ꯭ꯔꯦꯞ ꯑꯃꯥ ꯊꯝꯒꯗꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 6.7.8-ꯒꯤ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁ ꯑꯗꯨ ꯑꯅꯤ ꯊꯣꯛ ꯍꯦꯟꯒꯠꯍꯅꯒꯗꯕꯅꯤ (ꯀ꯭ꯂꯣꯖ 6.7.4)꯫
- (j) ꯑꯉꯃꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯉꯃꯕ ꯂꯝꯕꯤꯁꯤꯡ. ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯤ ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠꯅꯥ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯗ ꯀ꯭ꯂꯣꯖ 6.7.3(b)-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯕ ꯚꯦꯂꯣꯁꯤꯇꯤ, ꯅꯠꯔꯒꯥ 0.8-ꯗꯒꯤ ꯍꯦꯟꯕ ꯐ꯭ꯔꯨꯗ ꯅꯝꯕꯔ (Froude number) ꯄꯤꯔꯕ ꯃꯐꯝꯗ, ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨ ꯃꯤꯠꯌꯦꯡ (g)-ꯒꯤ ꯕꯜꯀꯤꯡ ꯇꯧꯔꯕ ꯐ꯭ꯂꯣꯒꯤꯗꯃꯛ ꯁꯔꯨꯛ 9-ꯒꯤ ꯃꯈꯥꯗ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯔꯕ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯁꯨꯠ (chute), ꯁ꯭ꯇꯦꯞ ꯂꯩꯕ ꯆꯦꯅꯦꯜ (stepped channel) ꯅꯠꯔꯒꯥ ꯗ꯭ꯔꯣꯞ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔꯁꯤꯡꯒꯤ (drop structure) ꯁꯦꯔꯤꯖ ꯑꯃꯥ ꯑꯣꯏꯒꯗꯕꯅꯤ, ꯑꯉꯃꯕ ꯆꯦꯅꯦꯜꯁꯤꯡꯒꯤꯗꯃꯛ ꯇꯦꯕꯜ 6.7-ꯒꯤ ꯐ꯭ꯔꯤꯕꯣꯔꯗ ꯑꯃꯁꯨꯡ ꯍꯦꯟꯅꯥ ꯐꯥꯔꯕ ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠꯇ ꯍꯣꯡꯂꯛꯄ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯑꯃꯁꯨꯡ ꯑꯥꯎꯠꯂꯦꯠꯇ ꯑꯦꯅꯔꯖꯤ ꯗꯤꯁꯤꯄꯦꯇꯔ (energy dissipator) ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ꯫ 5%-ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯑꯉꯃꯕ ꯂꯝꯕꯤ ꯑꯃꯗ, ꯒ꯭ꯔꯦꯠ ꯈꯛꯇꯃꯛ ꯂꯩꯕ ꯏꯟꯂꯦꯠꯁꯤꯡ ꯁꯤꯖꯤꯟꯅꯔꯣꯏꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯏꯟꯂꯦꯠꯁꯤꯡ ꯑꯁꯤ ꯑꯉꯃꯕ ꯒꯇꯔ ꯑꯃꯒꯤ ꯕꯥꯏꯄꯥꯁ ꯐ꯭ꯂꯣꯁꯤꯡꯒꯥ (bypass flow) ꯂꯣꯌꯅꯅ ꯀ꯭ꯂꯣꯖ 6.6.4-ꯒꯤ ꯀꯦꯜꯀꯨꯂꯦꯁꯟꯅꯥ ꯊꯝꯒꯗꯕꯅꯤ; 10%-ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯑꯉꯃꯕ ꯂꯝꯕꯤ ꯑꯃꯗ, ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯆꯦꯛ ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯊꯧꯗꯣꯛꯁꯤꯡꯗ ꯂꯝꯕꯤꯒꯤ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯇꯦꯕꯜ 6.3-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ ꯊꯝꯕ ꯂꯥꯞ ꯊꯥꯛꯇ ꯇ꯭ꯔꯥꯟꯁꯚꯔꯁ ꯒ꯭ꯔꯦꯠ ꯇꯧꯔꯕ ꯆꯦꯅꯦꯜꯁꯤꯡ (transverse grated channel) ꯅꯠꯔꯒꯥ ꯀꯔꯕ ꯏꯟꯂꯦꯠꯁꯤꯡꯅꯥ ꯊꯤꯡꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯂꯤꯃꯤꯠ ꯑꯗꯨꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ ꯊꯝꯕ ꯉꯃꯗꯕ ꯃꯐꯝꯗ, ꯍꯦꯟꯕ ꯑꯗꯨ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯁꯥꯏꯗ ꯆꯦꯅꯦꯜ ꯅꯠꯔꯒꯥ ꯁ꯭ꯇꯦꯞ ꯂꯩꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯄꯨꯒꯗꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯂꯝꯕꯤ ꯑꯗꯨ, ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯏꯚꯦꯀꯨꯌꯦꯁꯟ ꯔꯨꯠ (evacuation route) ꯑꯃꯥ ꯅꯠꯇ꯭ꯔꯕꯗꯤ, ꯊꯧꯗꯣꯛ ꯑꯗꯨꯗ ꯊꯤꯡꯂꯦ ꯍꯥꯌꯅꯥ ꯂꯧꯏ꯫ ꯐ꯭ꯂꯣ ꯄꯨꯕ ꯈꯣꯡꯊꯥꯡꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯐꯨꯠꯄꯥꯊꯁꯤꯡꯗ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯁꯥꯏꯗ ꯆꯦꯅꯦꯜ ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ꯫
- (k) ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯣꯏꯕ ꯆꯤꯡꯒꯤ ꯂꯝꯕꯤꯁꯤꯡ. ꯀ꯭ꯂꯣꯖ ꯑꯁꯤꯅꯥ ꯑꯔꯊ ꯄꯤꯔꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ ꯆꯤꯡꯒꯤ ꯀꯦꯆꯃꯦꯟꯠ ꯑꯃꯗ ꯂꯩꯕ ꯂꯝꯕꯤ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯃꯈꯣꯌꯒꯤ ꯃꯔꯛꯇ ꯏꯝꯐꯥꯜꯗꯒꯤ ꯖꯤꯔꯤꯕꯥꯝ ꯐꯥꯎꯕ NH-37 ꯑꯃꯁꯨꯡ NH-2, ꯂꯝꯕꯤ ꯑꯃꯒꯤ ꯏꯔꯝ ꯑꯁꯤ ꯂꯝꯕꯤ ꯑꯗꯨꯒꯤꯗꯃꯛ ꯈꯛꯇꯗ ꯅꯠꯇꯅꯥ ꯃꯁꯤꯒꯤ ꯃꯊꯛꯀꯤ ꯂꯝꯒꯤꯗꯃꯛꯀꯤꯁꯨ ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯅꯤ꯫ ꯑꯁꯤꯒꯨꯝꯕ ꯂꯝꯕꯤ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯂꯝꯕꯤꯒꯤ ꯃꯄꯨ, PWD, ꯅꯦꯁꯅꯦꯜ-ꯍꯥꯏꯋꯦꯒꯤ ꯑꯦꯖꯦꯟꯁꯤ ꯑꯃꯥ, IMC ꯅꯠꯔꯒꯥ ꯑꯇꯣꯞꯄ ꯎꯔꯕꯟ ꯂꯣꯀꯜ ꯕꯣꯗꯤ ꯑꯃꯥ, ꯅꯠꯔꯒꯥ ꯆꯤꯡꯒꯤ ꯂꯝꯁꯤꯡꯗ ꯂꯝꯕꯤ ꯁꯥꯒꯠꯂꯤꯕ ꯗꯤꯄꯥꯔꯠꯃꯦꯟꯠ ꯑꯗꯨꯒꯤ ꯊꯕꯛ ꯑꯣꯏꯅꯥ, ꯃꯈꯥꯒꯤꯁꯤꯡ ꯂꯩꯒꯗꯕꯅꯤ: (i) ꯃꯊꯛꯀꯤ ꯂꯝ ꯑꯗꯨꯅꯥ ꯂꯝꯕꯤꯒꯤ ꯃꯥꯏꯀꯩꯗ ꯏꯁꯤꯡ ꯆꯦꯟꯕ ꯃꯐꯝꯗ ꯀꯠ ꯁ꯭ꯂꯣꯞ (cut slope) ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯊꯛꯇ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯀꯦꯆ-ꯋꯥꯇꯔ ꯈꯣꯡꯕꯥꯟ (catch-water drain) ꯑꯃꯥ, ꯃꯁꯤꯅꯥ ꯀꯠ ꯑꯗꯨꯒꯤ ꯃꯊꯛꯇ ꯅꯠꯇꯅꯥ ꯃꯍꯧꯁꯥꯒꯤ ꯆꯦꯅꯦꯜ ꯑꯃꯗ ꯅꯠꯔꯒꯥ ꯀ꯭ꯔꯣꯁ-ꯗ꯭ꯔꯦꯅꯦꯖ ꯋꯔꯛ (cross-drainage work) ꯑꯃꯗ ꯏꯁꯤꯡ ꯊꯥꯗꯣꯀꯄ; (ii) ꯆꯤꯡꯒꯤ ꯃꯥꯏꯀꯩꯗ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯁꯥꯏꯗ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ (IRC:SP:42-2014, cl. 8.5.1); (iii) ꯈꯣꯡ ꯑꯃꯁꯨꯡ ꯁ꯭ꯇ꯭ꯔꯤꯝ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯀ꯭ꯔꯣꯁ-ꯗ꯭ꯔꯦꯅꯦꯖ ꯋꯔꯛ ꯑꯃꯥ, ꯑꯃꯁꯨꯡ ꯃꯤꯠꯌꯦꯡ (g) ꯑꯃꯁꯨꯡ (h)-ꯒꯤ ꯐꯦꯛꯇꯔꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ ꯇꯦꯕꯜ 6.1-ꯒꯤ ꯗꯤꯖꯥꯏꯟ AEP-ꯗ ꯁꯥꯏꯗ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯠꯇꯅꯥ ꯃꯁꯤꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤꯗꯒꯤ ꯍꯦꯟꯗꯅꯕ ꯂꯥꯞ ꯊꯥꯛꯇ ꯀꯜꯚꯔꯠꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯁ꯭ꯀꯄꯔꯁꯤꯡ (scupper); (iv) ꯇꯝꯄꯥꯛꯀꯤ ꯃꯥꯏꯀꯩꯗ ꯂꯩꯕ ꯁ꯭ꯀꯄꯔ, ꯀꯜꯚꯔꯠ ꯑꯃꯁꯨꯡ ꯁꯥꯏꯗ ꯈꯣꯡꯕꯥꯟ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯑꯥꯎꯠꯂꯦꯠꯇ, ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯆꯦꯠꯄ ꯃꯍꯧꯁꯥꯒꯤ ꯆꯦꯅꯦꯜ ꯑꯃꯗ ꯅꯠꯔꯒꯥ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯄꯨꯕ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯁꯨꯠ, ꯀꯦꯁꯀꯦꯗ (cascade) ꯅꯠꯔꯒꯥ ꯄꯥꯏꯞ ꯑꯃꯥ, ꯑꯦꯅꯔꯖꯤ ꯗꯤꯁꯤꯄꯦꯇꯔ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯂꯝꯕꯤꯒꯤ ꯔꯟꯑꯣꯐ ꯑꯁꯤ PWD, ꯅꯦꯁꯅꯦꯜ-ꯍꯥꯏꯋꯦꯒꯤ ꯑꯦꯖꯦꯟꯁꯤ ꯅꯠꯔꯒꯥ ꯂꯝꯕꯤꯒꯤ ꯑꯇꯣꯞꯄ ꯃꯄꯨ ꯑꯃꯠꯇꯅꯥ ꯉꯥꯛꯊꯣꯛꯇꯕ ꯅꯥꯄꯣꯝ ꯑꯃꯗ ꯀꯩꯗꯧꯉꯩꯗꯁꯨ ꯊꯥꯗꯣꯛꯂꯣꯏ, ꯐꯤꯜ (fill), ꯔꯤꯇꯦꯅꯤꯡ ꯋꯣꯜ (retaining wall) ꯅꯠꯔꯒꯥ ꯃꯈꯥꯗ ꯂꯩꯕ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯒꯤ ꯂꯝꯗꯁꯨ ꯊꯥꯗꯣꯛꯂꯣꯏ; (v) ꯀ꯭ꯂꯣꯖ 6.12.5-ꯒꯤ ꯁꯥꯏꯖꯗꯒꯤ ꯍꯟꯊꯗꯕ, ꯀ꯭ꯂꯣꯖ 6.12-ꯒꯤ ꯃꯈꯥꯗ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯔꯕ ꯑꯃꯁꯨꯡ IRC:SP:42-2014 cl. 7.1.4-ꯅꯥ ꯂꯝꯕꯤ ꯑꯗꯨꯒꯤꯗꯃꯛ ꯃꯊꯧ ꯇꯥꯕꯗꯒꯤ ꯍꯟꯊꯗꯕ ꯀꯜꯚꯔꯠꯁꯤꯡ; IRC:SP:48-1998, ꯍꯤꯜ ꯔꯣꯗ ꯃꯦꯅꯨꯌꯦꯜ (Hill Road Manual), ꯃꯁꯤꯒꯤ ꯏꯔꯝꯒꯤ ꯄ꯭ꯔꯣꯚꯤꯖꯟꯁꯤꯡ, ꯃꯈꯣꯌ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ ꯄꯥꯈꯤꯗꯦ [TBC], ꯃꯤꯠꯌꯦꯡ ꯑꯁꯤꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯀꯟꯕ ꯑꯣꯏꯔꯕꯗꯤ, ꯃꯈꯣꯌ ꯆꯠꯅꯩ; ꯑꯃꯁꯨꯡ (vi) ꯂꯝꯕꯤ ꯑꯗꯨ ꯁꯥꯕ, ꯄꯥꯛꯊꯣꯛꯍꯟꯕ ꯅꯠꯔꯒꯥ ꯃꯦꯟꯇꯦꯅꯦꯟꯁ ꯇꯧꯕꯗꯒꯤ, ꯅꯠꯔꯒꯥ ꯃꯁꯤꯒꯤ ꯃꯅꯥꯛꯇ ꯆꯤꯡ ꯀꯛꯄꯗꯒꯤ ꯊꯣꯀꯄ ꯁ꯭ꯄꯣꯏꯜ (spoil) ꯅꯠꯔꯒꯥ ꯇꯨꯝꯊꯣꯛꯈꯤꯕ ꯄꯣꯠꯁꯤꯡ ꯑꯃꯠꯇꯥ ꯈꯣꯡ ꯑꯃꯗ ꯅꯠꯔꯒꯥ ꯃꯍꯧꯁꯥꯒꯤ ꯏꯔꯝꯒꯤ ꯑꯇꯣꯞꯄ ꯂꯥꯏꯟ ꯑꯃꯗ ꯅꯠꯔꯒꯥ ꯃꯁꯤꯒꯤ ꯃꯅꯥꯛꯇ, ꯅꯠꯔꯒꯥ ꯅꯣꯡ ꯆꯨꯕꯒꯤ ꯊꯧꯗꯣꯛ ꯑꯃꯅꯥ ꯃꯗꯨꯗ ꯄꯨꯔꯀꯄ ꯌꯥꯕ ꯅꯥꯄꯣꯝ ꯑꯃꯗ ꯊꯝꯂꯣꯏꯗꯕꯅꯤ꯫ ꯃꯤꯠꯌꯦꯡ ꯑꯁꯤꯁꯤꯡꯃꯛ ꯆꯤꯡꯒꯤ ꯀꯦꯆꯃꯦꯟꯠ ꯑꯃꯗ ꯂꯩꯕ ꯔꯦꯜꯋꯦ ꯐꯣꯔꯃꯦꯁꯟ (railway formation) ꯑꯃꯒꯤ ꯏꯔꯝꯗꯁꯨ ꯆꯠꯅꯩ꯫
- (l) ꯅꯥꯄꯣꯝ ꯂꯩꯕ ꯁꯥꯏꯠꯁꯤꯡ, ꯆꯤꯡ ꯀꯛꯄ ꯑꯃꯁꯨꯡ ꯔꯤꯇꯦꯅꯤꯡ ꯋꯣꯜꯁꯤꯡ. ꯃꯊꯛꯀꯤ ꯂꯝ ꯑꯗꯨꯅꯥ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯒꯤ, ꯃꯁꯤꯒꯤ ꯀꯠꯀꯤ ꯅꯠꯔꯒꯥ ꯃꯁꯤꯒꯤ ꯔꯤꯇꯦꯅꯤꯡ ꯋꯣꯜꯒꯤ ꯃꯥꯏꯀꯩꯗ ꯏꯁꯤꯡ ꯆꯦꯟꯕ ꯁꯥꯏꯠ ꯑꯃꯗ, ꯂꯝ ꯑꯗꯨꯒꯤ ꯔꯟꯑꯣꯐ ꯑꯁꯤ ꯃꯈꯣꯌꯒꯤ ꯃꯊꯛꯇ, ꯃꯊꯛꯀꯤ ꯂꯝꯗꯒꯤ ꯇꯦꯕꯜ 6.1-ꯒꯤ ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯒꯤꯗꯃꯛ, ꯃꯤꯠꯌꯦꯡ (g) ꯑꯃꯁꯨꯡ (h)-ꯒꯤ ꯐꯦꯛꯇꯔꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ, ꯁꯥꯏꯖ ꯂꯦꯞꯂꯕ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯗꯥꯏꯚꯔꯁꯟ ꯈꯣꯡꯕꯥꯟ (diversion drain) ꯑꯃꯅꯥ ꯊꯤꯡꯒꯗꯕꯅꯤ, ꯕꯤꯜꯗꯤꯡ ꯑꯗꯨꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯅꯠꯔꯒꯥ ꯃꯗꯨꯒꯤ ꯃꯥꯏꯀꯩꯗ ꯆꯠꯇꯕ 1% AEP-ꯒꯤ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ꯫ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯁꯨꯡ ꯃꯁꯤꯒꯤ ꯃꯊꯛꯇ ꯂꯩꯕ ꯀꯠ ꯅꯠꯔꯒꯥ ꯔꯤꯇꯦꯅꯤꯡ ꯋꯣꯜꯒꯤ ꯃꯔꯛꯀꯤ ꯃꯐꯝ ꯑꯁꯤ ꯄꯦꯚ ꯇꯧꯒꯗꯕꯅꯤ ꯅꯠꯔꯒꯥ ꯂꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯏꯔꯝ ꯄꯤꯒꯗꯕꯅꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯏꯁꯤꯡ ꯑꯁꯤ ꯕꯤꯜꯗꯤꯡꯒꯤ ꯃꯥꯏꯀꯩꯗ ꯂꯦꯞꯂꯣꯏ ꯅꯠꯔꯒꯥ ꯀꯠ ꯑꯗꯨꯒꯤ ꯈꯣꯡꯗ ꯆꯨꯞꯂꯣꯏ, ꯑꯃꯁꯨꯡ ꯑꯅꯤꯃꯛꯅꯥ ꯃꯤꯠꯌꯦꯡ (k)(iv)-ꯅꯥ ꯃꯊꯧ ꯇꯥꯕꯒꯨꯝꯅꯥ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯅꯠꯔꯒꯥ ꯆꯦꯠꯄ ꯃꯍꯧꯁꯥꯒꯤ ꯆꯦꯅꯦꯜ ꯑꯃꯗ ꯏꯁꯤꯡ ꯊꯥꯗꯣꯛꯀꯗꯕꯅꯤ, ꯃꯈꯥꯒꯤ ꯅꯥꯄꯣꯝꯗ ꯅꯠꯇꯦ꯫ ꯅꯥꯄꯣꯝ ꯑꯃꯥ ꯊꯤꯡꯖꯤꯜꯂꯤꯕ ꯔꯤꯇꯦꯅꯤꯡ ꯋꯣꯜ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯃꯁꯤꯒꯤ ꯈꯣꯡꯗ ꯂꯩꯕ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯏꯁꯤꯡ ꯊꯥꯗꯣꯀꯄ ꯋꯤꯞ ꯄꯥꯏꯞꯁꯤꯡ (weep pipe) ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯈꯥꯒꯤ ꯅꯥꯄꯣꯝꯗ ꯅꯠꯔꯒꯥ ꯃꯈꯥꯗ ꯂꯩꯕ ꯋꯣꯜ ꯑꯃꯒꯤ ꯕꯦꯛꯐꯤꯜꯗ (backfill) ꯅꯠꯇꯦ: AIIB ꯄ꯭ꯔꯣꯖꯦꯛꯠꯀꯤ ꯃꯍꯧꯁꯥꯒꯤ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯦꯛꯁꯟꯁꯤꯡꯅꯥ "ꯄꯣꯔ ꯋꯥꯇꯔ ꯄ꯭ꯔꯦꯁꯔ ꯊꯥꯗꯣꯛꯅꯕ" ("release pore water pressure") 5 m ꯈꯨꯗꯤꯡꯗ 50-mm PVC ꯋꯤꯞ ꯄꯥꯏꯞꯁꯤꯡ ꯃꯃꯥꯡꯗꯒꯤ ꯎꯠꯂꯤ (AIIB IEE)꯫ ꯑꯁꯤꯒꯨꯝꯕ ꯁꯥꯏꯠ ꯑꯃꯗ ꯌꯨꯝꯊꯛ ꯑꯃꯁꯨꯡ ꯄꯦꯚ ꯇꯧꯔꯕ ꯑꯦꯔꯤꯌꯥꯒꯤ ꯔꯟꯑꯣꯐ ꯑꯁꯤꯅꯥ ꯀ꯭ꯂꯣꯖ 4.11-ꯒꯤ ꯆꯤꯡꯒꯤ ꯔꯨꯜ ꯃꯇꯨꯡ ꯏꯟꯅꯒꯗꯕꯅꯤ꯫ ꯃꯤꯠꯌꯦꯡ ꯑꯁꯤꯁꯤꯡꯅꯥ ꯂꯩꯔꯤꯕ ꯅꯥꯄꯣꯝꯒꯤ ꯔꯨꯜꯁꯤꯡꯗ ꯗꯤꯖꯥꯏꯟ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯑꯃꯥ ꯄꯤꯔꯤ: IMC (3rd Amendment) 2024-ꯒꯤ ꯗ꯭ꯔꯥꯐꯠ, ꯃꯁꯤꯒꯤ ꯃꯈꯥꯗ "ꯗꯤꯒ꯭ꯔꯤ 30-ꯗꯒꯤ ꯍꯦꯟꯕ ꯅꯥꯄꯣꯝ ꯂꯩꯕ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯗ ꯀꯟꯁ꯭ꯇ꯭ꯔꯛꯁꯟ ꯑꯃꯠꯇꯥ ꯌꯥꯍꯟꯂꯣꯏ" ("no construction will be permitted in the areas which have a slope of more than 30 degrees"), ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯑꯁꯤ "ꯗꯤꯒ꯭ꯔꯤ 21-30-ꯒꯤ ꯅꯥꯄꯣꯝ ꯂꯩꯕ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯗ ꯐ꯭ꯂꯣꯔ ꯑꯅꯤ ꯅꯠꯔꯒꯥ 7m ꯑꯋꯥꯡꯕ ꯐꯥꯎꯕ ꯈꯛꯇꯃꯛ" ("only upto two floors or 7m height in areas which have a slope of 21-30 degrees") ꯌꯥꯍꯜꯂꯤ (92.1) ꯑꯃꯁꯨꯡ "ꯗꯤꯒ꯭ꯔꯤ 30-ꯗꯒꯤ ꯍꯦꯟꯕ ꯅꯥꯄꯣꯝ ꯂꯩꯕ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯗ ꯅꯥꯄꯣꯝ ꯀꯛꯄ ꯑꯃꯠꯇꯥ ꯌꯥꯍꯟꯂꯣꯏ" ("no cutting of slopes will be permitted in the areas which have a slope of more than 30 degrees") (92.2), ꯃꯁꯤ "ꯁ꯭ꯇꯦꯠ ꯂꯩꯉꯥꯛꯅꯥ … ꯊꯝꯒꯗꯕ ꯇꯥꯡꯗ ꯆꯠꯂꯛꯀꯅꯤ" ("come into force on such date as the State Government may … appoint") ꯍꯥꯌꯅꯥ ꯑꯣꯕꯖꯦꯛꯁꯟꯁꯤꯡꯒꯤꯗꯃꯛ ꯐꯣꯡꯗꯣꯛꯈꯤ, ꯃꯁꯤꯒꯤ ꯑꯔꯣꯏꯕ ꯁ꯭ꯇꯦꯇꯁ ꯀꯟꯐꯥꯔꯝ ꯇꯧꯈꯤꯗꯦ [TBC]; ꯃꯣꯗꯦꯜꯒꯤ ꯕꯥꯏ-ꯂꯣ 92 [TBC: ꯂꯣꯀꯜ ꯕꯣꯗꯤꯅꯥ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯕꯥꯏ-ꯂꯣꯖꯇ ꯅꯝꯕꯔ ꯑꯃꯁꯨꯡ ꯇꯦꯛꯁꯇ ꯆꯦꯛ ꯇꯧꯒꯗꯕꯅꯤ], ꯃꯁꯤ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ "ꯃꯤꯟ ꯁꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ 600 m-ꯗꯒꯤ ꯋꯥꯡꯕ ꯑꯃꯁꯨꯡ ꯑꯦꯕꯔꯦꯖ ꯗꯤꯒ꯭ꯔꯤ 30-ꯒꯤ ꯅꯥꯄꯣꯝ ꯂꯩꯕ ꯂꯝꯗ ꯀꯟꯁ꯭ꯇ꯭ꯔꯛꯁꯟ ꯑꯃꯠꯇꯥ ꯌꯥꯍꯟꯂꯣꯏꯗꯕꯅꯤ" ("No construction shall be permitted on land above 600 m from the mean sea level and with an average slope of 30 degrees") ꯍꯥꯌꯅꯥ ꯂꯩ ꯑꯃꯁꯨꯡ ꯄꯥꯕ ꯑꯗꯨꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ 600 m-ꯗꯒꯤ ꯋꯥꯡꯅꯥ ꯂꯩꯕ ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜ ꯄꯨꯝꯕ ꯊꯤꯡꯒꯅꯤ (NEER-ꯒꯤ ꯄꯥꯕ), ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯃꯁꯤ IMC-ꯒꯤ ꯇꯦꯛꯁꯠꯀꯥ ꯂꯣꯌꯅꯅ ꯄꯥꯏ; IS 14458, ꯃꯣꯗꯦꯜꯅꯥ ꯍꯥꯌꯔꯤꯕ ꯆꯤꯡꯒꯤ ꯂꯝꯁꯤꯡꯗ ꯔꯤꯇꯦꯅꯤꯡ ꯋꯣꯜꯁꯤꯡꯒꯤ ꯒꯥꯏꯗꯂꯥꯏꯟꯁ; ꯑꯃꯁꯨꯡ "ꯏꯔꯣꯖꯟ ꯑꯃꯁꯨꯡ ꯁꯦꯗꯤꯃꯦꯟꯇꯦꯁꯟ ꯀꯟꯇ꯭ꯔꯣꯜ" ("erosion and sedimentation control")-ꯒꯤ ꯒ꯭ꯔꯤꯟ-ꯕꯤꯜꯗꯤꯡ ꯀ꯭ꯔꯥꯏꯇꯦꯔꯤꯌꯟ꯫ ꯆꯤꯡꯒꯤ ꯂꯝꯁꯤꯡꯗ ꯕꯤꯜꯗꯤꯡ ꯕꯥꯏ-ꯂꯣ ꯑꯃꯠꯇꯥ ꯆꯠꯅꯗꯦ: ꯃꯤꯠꯌꯦꯡ ꯑꯁꯤꯅꯥ ꯄꯕ꯭ꯂꯤꯛ ꯋꯔꯛꯁ ꯑꯃꯁꯨꯡ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ ꯂꯧꯁꯤꯟꯕ ꯕꯣꯗꯤ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯌꯧꯏ꯫
- (m) ꯆꯤꯡ–ꯇꯝꯄꯥꯛꯀꯤ ꯈꯥꯌꯗꯣꯛꯐꯝ, ꯂꯩꯃꯨ ꯑꯃꯁꯨꯡ ꯋꯦꯁ꯭ꯠ. ꯈꯣꯡ ꯅꯠꯔꯒꯥ ꯆꯤꯡꯒꯤ ꯈꯣꯡ ꯑꯃꯥ, ꯅꯠꯔꯒꯥ ꯃꯗꯨ ꯂꯧꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ, ꯇꯝꯄꯥꯛꯀꯤ ꯂꯝ ꯅꯠꯔꯒꯥ ꯂꯣꯛꯇꯥꯛꯀꯤ ꯑꯀꯣꯌꯕꯗ ꯂꯩꯕ ꯐꯥꯔꯕ ꯂꯝꯗ ꯌꯧꯕ ꯃꯐꯝꯗ, ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠ ꯍꯟꯊꯔꯀꯄ ꯃꯐꯝ ꯑꯗꯨꯒꯤ ꯃꯊꯛꯇ ꯁꯔꯨꯛ 9 (ꯀ꯭ꯂꯣꯖ 9.8)-ꯒꯤ ꯃꯈꯥꯗ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯔꯕ ꯁꯤꯜꯠ ꯇ꯭ꯔꯦꯞ (silt trap) ꯑꯃꯥ ꯊꯝꯒꯗꯕꯅꯤ, ꯃꯦꯁꯤꯅꯒꯤ ꯆꯡꯂꯛꯄꯒꯤ ꯂꯝꯕꯤ ꯑꯃꯁꯨꯡ ꯈꯣꯡ, ꯄꯥꯠꯀꯤ ꯃꯄꯥꯟ, ꯂꯧꯕꯨꯛ ꯅꯠꯔꯒꯥ ꯅꯥꯄꯣꯝ ꯅꯠꯇꯕ ꯄꯨꯟꯁꯤꯟꯅꯕ ꯃꯐꯝ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ, ꯃꯤꯠꯌꯦꯡ (i)-ꯒꯤ ꯁꯦꯗꯤꯃꯦꯟꯠꯀꯤꯗꯃꯛ ꯁꯥꯏꯖ ꯂꯦꯞꯂꯒꯥ ꯃꯤꯠꯌꯦꯡ (f)-ꯒꯤ ꯇꯥꯡꯁꯤꯡꯗ ꯑꯃꯁꯨꯡ ꯌꯥꯝꯅꯥ ꯅꯣꯡ ꯆꯨꯕ ꯅꯨꯃꯤꯠ ꯈꯨꯗꯤꯡꯒꯤ ꯃꯇꯨꯡꯗ ꯁꯦꯡꯗꯣꯛꯀꯗꯕꯅꯤ (ꯁꯔꯨꯛ 10)꯫ ꯆꯤꯡ ꯀꯛꯄꯗꯒꯤ ꯊꯣꯀꯄ ꯁ꯭ꯄꯣꯏꯜ ꯑꯃꯁꯨꯡ ꯀꯟꯁ꯭ꯇ꯭ꯔꯛꯁꯟ ꯑꯃꯁꯨꯡ ꯗꯦꯃꯣꯂꯤꯁꯅꯒꯤ ꯋꯦꯁ꯭ꯠ ꯑꯃꯠꯇꯥ ꯅꯣꯡ ꯆꯨꯕꯒꯤ ꯊꯧꯗꯣꯛ ꯑꯃꯅꯥ ꯈꯣꯡꯕꯥꯟ, ꯈꯣꯡ, ꯄꯥꯠ ꯅꯠꯔꯒꯥ ꯂꯣꯛꯇꯥꯛꯇ ꯄꯨꯔꯀꯄ ꯌꯥꯕ ꯃꯐꯝꯗ ꯊꯝꯂꯣꯏꯗꯕꯅꯤ; ꯂꯣꯛꯇꯥꯛ ꯑꯦꯛꯠꯀꯤ ꯃꯐꯝꯒꯤ ꯃꯅꯨꯡꯗ, "ꯂꯦꯟꯗ ꯐꯤꯂꯤꯡꯒꯤ ꯄꯥꯟꯗꯝꯗ ꯁꯍꯔ ꯅꯠꯔꯒꯥ ꯇꯥꯎꯟꯒꯤ ꯋꯦꯁ꯭ꯠ ꯊꯥꯗꯣꯛꯄ" ("Dumping of city or town waste for the purpose to land filling") ꯑꯃꯁꯨꯡ "ꯂꯦꯟꯗꯁ꯭ꯀꯦꯞ ꯏꯔꯝ ꯌꯥꯑꯣꯅꯥ ꯆꯤꯡꯁꯤꯡ, ꯃꯍꯧꯁꯥꯒꯤ ꯃꯑꯣꯡꯁꯤꯡ ꯁꯦꯝꯖꯤꯟꯕ ꯅꯠꯔꯒꯥ ꯍꯣꯡꯗꯣꯀꯄ" ("Dressing or altering of hills, natural features including landscape drainage") ꯑꯁꯤ ꯕꯐꯔ ꯖꯣꯟꯗ ꯃꯃꯥꯡꯗꯒꯤ ꯊꯤꯡꯂꯦ (ꯁꯦꯛꯁꯟ 19(v) ꯑꯃꯁꯨꯡ (viii))꯫ ꯁ꯭ꯇ꯭ꯔꯤꯝ ꯑꯃꯗ ꯊꯝꯂꯕ ꯇ꯭ꯔꯦꯞ ꯅꯠꯔꯒꯥ ꯁ꯭ꯀ꯭ꯔꯤꯟ ꯑꯃꯅꯥ ꯑꯥꯎꯠꯐꯣꯜ ꯑꯃꯍꯦꯛꯇꯗ ꯃꯁꯤꯒꯤ 1% AEP-ꯒꯤ ꯂꯦꯚꯦꯜ ꯍꯦꯟꯒꯠꯍꯟꯂꯣꯏꯗꯕꯅꯤ (ꯀ꯭ꯂꯣꯖ 5.8.5(f)) ꯑꯃꯁꯨꯡ ꯃꯁꯤꯒꯤ ꯃꯊꯛꯇ ꯏꯁꯤꯡ ꯆꯦꯟꯂꯕꯁꯨ ꯃꯥꯡꯍꯟ ꯇꯥꯛꯍꯟꯗꯅꯕ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ꯫ ꯇ꯭ꯔꯦꯞ ꯑꯁꯤ ꯇ꯭ꯔꯤꯠꯃꯦꯟꯠꯀꯤ ꯊꯕꯛ ꯅꯠꯇꯦ: ꯅꯣꯡ ꯆꯨꯗꯕ ꯃꯇꯝꯒꯤ ꯆꯦꯟꯕ ꯑꯁꯤ ꯃꯤꯠꯌꯦꯡ (e) ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 8.9-ꯒꯤ ꯃꯈꯥꯗ ꯏꯟꯇꯔꯁꯦꯞꯇ ꯇꯧꯏ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. CPHEEO (2019)-ꯒꯤ ꯃꯦꯅꯨꯌꯦꯜꯅꯥ ꯃꯁꯤꯒꯤ ꯒ꯭ꯂꯣꯁꯔꯤꯗ ꯃꯦꯖꯔ ꯑꯃꯁꯨꯡ ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯁꯤꯡꯒꯤ ꯑꯔꯊ ꯄꯤꯔꯤ ꯑꯗꯨꯕꯨ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤꯗꯃꯛ ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗ ꯑꯃꯠꯇꯥ ꯄꯤꯗꯦ꯫ APWA 5600 (2006, 5601.8)-ꯅꯥ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯁꯤꯅꯥ 1% ꯄꯤꯛ ꯄꯨꯒꯗꯕꯅꯤ ꯑꯃꯁꯨꯡ, ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯃꯅꯨꯡꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯍꯟꯊꯕ ꯃꯐꯝꯗ, ꯑꯇꯣꯞꯄ ꯑꯗꯨ ꯄꯨꯅꯕ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ ꯍꯥꯌꯅꯥ ꯃꯊꯧ ꯇꯥꯏ꯫ ꯀ꯭ꯂꯣꯖ 6.3.3-ꯅꯥ ꯃꯄꯨꯡ ꯐꯥꯕ ꯄꯥꯏꯞꯀꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯅꯠꯇꯅꯥ ꯀꯨꯞꯂꯕ ꯏꯟꯂꯦꯠꯀꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯈꯛꯇꯃꯛ ꯂꯧꯊꯣꯀꯏ, ꯃꯔꯝꯗꯤ ꯇꯧꯔꯤꯕ ꯃꯑꯣꯡꯗ ꯄꯥꯏꯞꯁꯤꯡꯅꯥ ꯏꯟꯂꯦꯠꯁꯤꯡꯅꯥ ꯆꯡꯍꯟꯕꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯏꯁꯤꯡ ꯂꯧꯕ ꯉꯝꯗꯦ꯫ ꯁꯦꯒꯁꯤꯡꯗ ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯊꯤꯡꯂꯕ ꯃꯇꯝꯒꯤ ꯆꯦꯛ ꯑꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ; ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯃꯁꯤ ꯊꯝꯂꯤ, ꯃꯔꯝꯗꯤ ꯏꯝꯐꯥꯜꯒꯤ ꯊꯦꯡꯅꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ ꯐꯨꯠꯄꯥꯊꯁꯤꯡꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯀꯟꯕ ꯅꯣꯡ ꯆꯨꯕ ꯃꯇꯝꯗ ꯃꯇꯝ ꯀꯌꯥꯗ ꯂꯩꯃꯨꯅꯥ ꯃꯄꯨꯟꯕ ꯅꯠꯔꯒꯥ ꯁꯣꯂꯤꯗ ꯋꯦꯁ꯭ꯠꯅꯥ ꯊꯤꯡꯂꯤ (CPHEEO 2019 Part A, Ch 1 and 2, ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯁꯣꯂꯤꯗ ꯋꯦꯁ꯭ꯠ ꯊꯥꯗꯣꯀꯄꯒꯤ ꯃꯇꯥꯡꯗ Figures 1.2 and 2.1)꯫ ꯀꯦꯆꯃꯦꯟꯠꯁꯤꯡꯒꯤ ꯃꯔꯛꯇ ꯍꯣꯡꯗꯣꯀꯄ ꯊꯤꯡꯕ ꯑꯁꯤ DID Malaysia 2008-ꯒꯤ ꯁꯕꯃꯤꯁꯟ ꯆꯦꯛꯂꯤꯁ꯭ꯠ ꯃꯇꯨꯡ ꯏꯟꯅꯔꯤ, ꯃꯁꯤꯅꯥ ꯏꯟꯇꯔ-ꯀꯦꯆꯃꯦꯟꯠ ꯗꯥꯏꯚꯔꯁꯟ ꯊꯤꯡꯏ꯫ ꯀ꯭ꯂꯣꯖ 6.3.6 ꯑꯁꯤ ꯃꯅꯤꯄꯨꯔꯒꯤꯗꯃꯛ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯃꯁꯤꯗ ꯁꯔꯨꯛ ꯑꯅꯤ ꯂꯩ, ꯃꯔꯝꯗꯤ ꯁ꯭ꯇꯦꯠꯀꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯃꯑꯣꯡ ꯑꯅꯤꯗ ꯐꯦꯜ ꯇꯧꯏ, ꯃꯁꯤ ꯁꯦꯡꯂꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯐꯥꯔꯕ ꯂꯩꯃꯥꯏ ꯂꯧꯕ ꯁꯔꯨꯛ ꯑꯁꯤꯒꯤ ꯀ꯭ꯔꯥꯏꯇꯦꯔꯤꯌꯥꯁꯤꯡꯅꯥ ꯎꯗꯦ꯫ ꯑꯍꯥꯅꯕꯗꯤ ꯁꯤꯋꯦꯖꯅꯤ꯫ ꯖꯨꯟ 2020-ꯗ ꯀꯃꯤꯁꯟ ꯇꯧꯈꯤꯕ ꯏꯝꯐꯥꯜꯒꯤ ꯁꯤꯋꯔꯦꯖ ꯐꯦꯖ I-ꯅꯥ IMC-ꯒꯤ ꯋꯥꯔꯗ 27-ꯒꯤ ꯃꯅꯨꯡꯗ 11 ꯌꯥꯎꯏ (ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ); "ꯁꯍꯔꯒꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯗ ꯁꯤꯋꯦꯖ ꯊꯣꯀꯄ ꯑꯁꯤ 70 MLD-ꯅꯤ ꯑꯃꯁꯨꯡ ꯂꯩꯔꯤꯕ ꯇ꯭ꯔꯤꯠꯃꯦꯟꯠ ꯐꯦꯁꯤꯂꯤꯇꯤꯁꯤꯡ ꯑꯁꯤ 44 MLD-ꯅꯤ" ("Sewage generation in urban areas is 70 MLD and existing treatment facilities are 44 MLD"), ꯌꯨꯝꯒꯤ ꯀꯅꯦꯛꯁꯟꯁꯤꯡ ꯇꯥꯔꯒꯦꯠ ꯇꯧꯈꯤꯕ 51,754-ꯒꯤ ꯃꯅꯨꯡꯗ 8,600-ꯗꯒꯤ 8,700 ꯐꯥꯎꯕ ꯂꯩꯈꯤ, ꯑꯃꯁꯨꯡ ꯏꯐ꯭ꯂꯨꯌꯦꯟꯠꯀꯤ "ꯑꯔꯣꯏꯕ ꯊꯥꯗꯣꯀꯄꯒꯤ ꯃꯑꯣꯡ" ("Final mode of disposal") ꯑꯁꯤ "ꯂꯧꯉꯥꯡꯒꯤ ꯀꯦꯅꯦꯜꯁꯤꯡ" ("Agriculture canals")-ꯅꯤ (O.A. 606/2018-ꯗ NGT-ꯗ ꯁ꯭ꯇꯦꯠꯀꯤ ꯔꯤꯄꯣꯔꯠ, ꯖꯨꯂꯥꯏ 2025); ꯑꯃꯁꯨꯡ ꯅꯝꯕꯨꯜ ꯇꯨꯔꯦꯜꯗ ꯆꯦꯟꯊꯔꯀꯄ ꯈꯣꯡꯕꯥꯟ 72-ꯅꯥ BOD 42.45-ꯗꯒꯤ 52.34 mg/L ꯑꯃꯁꯨꯡ COD 78.56-ꯗꯒꯤ 97.23 mg/L ꯄꯨꯏ (NGT-ꯗ ꯁ꯭ꯇꯦꯠꯀꯤ ꯔꯤꯄꯣꯔꯠ, ꯗꯤꯁꯦꯝꯕꯔ 2025), ꯇꯨꯔꯦꯜ ꯑꯗꯨꯒꯤ ꯃꯁꯥꯒꯤ BOD ꯑꯁꯤ CPCB-ꯅꯥ ꯁꯤꯡꯗꯥ ꯗꯦꯝꯗꯒꯤ ꯕꯤꯁ꯭ꯅꯨꯄꯨꯔ ꯐꯥꯎꯕ ꯃꯁꯤꯒꯤ ꯔꯤꯆꯇ 3.3-ꯗꯒꯤ 5.6 mg/L ꯊꯥꯖꯈꯤ (CPCB, 2025)꯫ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤꯅꯥ ꯁꯤꯋꯔꯁꯤꯡꯅꯤ, ꯑꯃꯁꯨꯡ ꯇꯨꯔꯦꯜꯁꯤꯡꯅꯥ ꯃꯈꯣꯌꯕꯨ ꯏꯁꯤꯡ ꯍꯥꯄꯆꯤꯟꯅꯥ ꯊꯨꯝꯍꯜꯂꯤ꯫ ꯆꯤꯡꯁꯤꯡꯗ, "ꯃꯅꯤꯄꯨꯔꯒꯤ ꯆꯤꯡꯒꯤ ꯂꯝꯁꯤꯡꯗ ꯁꯦꯞꯇꯤꯛ ꯇꯦꯉ꯭ꯛꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇ꯭ꯕꯤꯟ ꯁꯣꯛ ꯄꯤꯠꯁꯤꯡꯗ ꯍꯧꯖꯤꯛ ꯊꯥꯖꯕ ꯊꯝꯂꯤꯕ ꯑꯁꯤ ꯃꯥꯟꯅꯩ" ("The existing reliance on septic tanks and twin soak pits in the hilly regions of Manipur is appropriate") ꯑꯃꯁꯨꯡ "ꯑꯟꯗꯔꯒ꯭ꯔꯥꯎꯟꯗ ꯏꯔꯝꯒꯤ ꯏꯟꯐ꯭ꯔꯥꯁ꯭ꯇ꯭ꯔꯛꯆꯔ ꯌꯥꯝꯅꯥ ꯍꯟꯊꯅꯥ ꯂꯩ" ("minimal presence of underground drainage infrastructure") (ꯁ꯭ꯇꯦꯠꯀꯤ ꯔꯤꯄꯣꯔꯠ, ꯖꯨꯂꯥꯏ 2025), ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯆꯤꯡꯒꯤ ꯂꯩꯐꯝ ꯑꯃꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯅꯥ ꯄꯤꯠꯁꯤꯡꯅꯥ ꯊꯥꯗꯣꯀꯄ ꯑꯗꯨ ꯄꯨꯏ꯫ ꯃꯣꯗꯦꯜ ꯕꯥꯏ-ꯂꯣꯖꯅꯥ ꯃꯃꯥꯡꯗꯒꯤ ꯃꯊꯧ ꯇꯥꯗꯅꯥ ꯇꯣꯉꯥꯟꯅꯥ ꯊꯝꯕꯒꯤ ꯃꯥꯏꯀꯩꯗ ꯇꯥꯛꯂꯤ: ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯜ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯊꯣꯀꯄ ꯁꯣꯛ-ꯄꯤꯠ ꯑꯥꯎꯠꯂꯦꯠ ꯑꯃꯒꯤ ꯃꯃꯥꯡꯗ ꯃꯔꯛꯀꯤ ꯇ꯭ꯔꯤꯠꯃꯦꯟꯠ ꯆꯦꯝꯕꯔ ꯑꯃꯥ (ꯕꯥꯏ-ꯂꯣ 6(1)(A)), ꯁꯤꯋꯔ ꯑꯃꯥ 30 m-ꯒꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯔꯕꯗꯤ ꯀꯅꯦꯛꯠ ꯇꯧꯔꯕ ꯂꯦꯇ꯭ꯔꯤꯟ ꯑꯃꯥ (ꯕꯥꯏ-ꯂꯣ 27), ꯑꯃꯁꯨꯡ ꯁꯣꯏꯜ ꯄꯥꯏꯞ ꯅꯠꯔꯒꯥ ꯊꯤꯡꯂꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯄꯥꯏꯞ ꯑꯃꯠꯇꯥ ꯌꯥꯔꯣꯏ (ꯕꯥꯏ-ꯂꯣ 28)꯫ ꯃꯤꯠꯌꯦꯡ (a)-ꯗꯒꯤ (e) ꯐꯥꯎꯕ ꯑꯁꯤꯅꯥ ꯁꯦꯔꯤꯖ ꯑꯁꯤꯒꯤ ꯐꯥꯔꯕ ꯂꯝꯒꯤ ꯑꯦꯗꯤꯁꯟꯁꯤꯡꯒꯤ ꯀꯝꯕꯥꯏꯟꯗ-ꯁꯤꯋꯔꯒꯤ ꯔꯨꯜꯁꯤꯡ ꯃꯇꯨꯡ ꯏꯟꯅꯔꯤ: ꯁꯥꯏꯠ ꯑꯃꯅꯥ ꯃꯁꯤꯒꯤ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯉꯃꯈꯩ ꯐꯥꯎꯕ ꯇꯣꯉꯥꯟꯅꯥ ꯊꯝꯃꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯁꯤꯋꯔꯦꯖꯒꯤ ꯋꯥꯔꯗꯁꯤꯡ ꯁꯝꯃꯤꯟꯅꯔꯀꯄꯒꯥ ꯂꯣꯌꯅꯅ ꯁꯍꯔ ꯑꯁꯤꯅꯥ ꯄ꯭ꯂꯣꯠ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯍꯜꯂꯛꯇꯅꯥ ꯃꯁꯤꯒꯤ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯁꯤ ꯂꯝꯕꯤ ꯑꯃꯃꯃꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ ꯇꯣꯉꯥꯟꯅꯥ ꯊꯝꯕ ꯌꯥꯒꯅꯤ; ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯑꯃꯅꯥ ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯤ ꯄꯤꯛ ꯍꯦꯟꯒꯠꯍꯟꯗꯦ; ꯅꯟ-ꯔꯤꯇꯔꯟ ꯚꯥꯜꯚ ꯑꯃꯅꯥ ꯀꯅꯦꯛꯁꯟ ꯈꯨꯗꯤꯡꯃꯛ ꯉꯥꯛꯊꯣꯀꯏ, ꯃꯔꯝꯗꯤ ꯁꯔꯆꯥꯔꯖ ꯑꯣꯏꯔꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗꯒꯤ ꯍꯜꯂꯛꯄ ꯑꯗꯨ ꯁꯤꯋꯦꯖꯅꯤ; ꯈꯣꯡꯕꯥꯟ ꯑꯁꯤ ꯃꯁꯤ ꯑꯣꯏꯔꯤꯕ ꯀꯝꯕꯥꯏꯟꯗ ꯆꯦꯅꯦꯜ ꯑꯣꯏꯅꯥ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯏ, ꯃꯁꯤꯒꯤ ꯅꯣꯡ ꯆꯨꯗꯕ ꯃꯇꯝꯒꯤ ꯆꯦꯟꯕ ꯂꯧꯊꯣꯛꯂꯒꯥ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯂꯧꯕ ꯑꯃꯁꯨꯡ ꯅꯣꯡ ꯆꯨꯕꯒꯤ ꯊꯧꯗꯣꯛꯁꯤꯡꯒꯤ ꯃꯔꯛꯇ ꯁꯤꯋꯦꯖꯒꯤ ꯁꯣꯂꯤꯗꯁꯤꯡ ꯊꯨꯗꯣꯛꯇꯅꯕ ꯂꯣ-ꯐ꯭ꯂꯣ ꯆꯦꯅꯦꯜ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ; ꯑꯃꯁꯨꯡ ꯄꯥꯠ, ꯂꯣꯛꯇꯥꯛ ꯅꯠꯔꯒꯥ ꯄꯣꯂꯨꯠ ꯑꯣꯏꯕ ꯔꯤꯆ ꯑꯃꯗ ꯂꯩꯕ ꯑꯥꯎꯠꯐꯣꯜ ꯑꯁꯤ ꯏꯟꯇꯔꯁꯦꯞꯇ ꯑꯃꯁꯨꯡ ꯁ꯭ꯀ꯭ꯔꯤꯟ ꯇꯧꯏ, ꯃꯔꯝꯗꯤ ꯄꯥꯠꯁꯤꯡ ꯑꯁꯤ ꯇꯝꯄꯥꯛꯀꯤ ꯁ꯭ꯇꯣꯔꯦꯖꯅꯤ, ꯂꯝꯐꯦꯜꯄꯥꯠ ꯑꯁꯤ ꯊꯛꯅꯕ ꯏꯁꯤꯡꯒꯤ ꯍꯧꯔꯛꯐꯝ ꯑꯃꯥ ꯑꯣꯏꯒꯅꯤ, ꯑꯃꯁꯨꯡ ꯂꯣꯛꯇꯥꯛ ꯑꯦꯛꯠꯅꯥ ꯇ꯭ꯔꯤꯠ ꯇꯧꯗꯕ ꯁꯍꯔꯒꯤ ꯏꯐ꯭ꯂꯨꯌꯦꯟꯠ ꯑꯁꯤ ꯄꯥꯠ ꯑꯗꯨꯒꯤ ꯕꯐꯔ ꯖꯣꯟꯗꯒꯤ ꯃꯃꯥꯡꯗꯒꯤ ꯊꯤꯡꯂꯦ꯫ ꯃꯤꯠꯌꯦꯡ (e)-ꯅꯥ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯂꯧꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡꯗꯒꯤꯁꯨ ꯂꯥꯞꯅꯥ ꯊꯝꯃꯤ: ꯇꯝꯄꯥꯛꯀꯤ ꯂꯧꯕꯨꯛ ꯑꯁꯤ ꯃꯁꯤꯒꯤ ꯂꯧꯉꯥꯡꯒꯤ ꯂꯝ ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯁ꯭ꯇꯣꯔꯦꯖ ꯑꯅꯤꯃꯛ ꯑꯣꯏꯔꯤ, ꯑꯃꯁꯨꯡ 2014-ꯒꯤ ꯑꯦꯛꯠꯅꯥ ꯃꯁꯤꯒꯤ "ꯏꯔꯝꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡ, ꯄꯨꯈ꯭ꯔꯤꯁꯤꯡ, ꯀꯦꯅꯦꯜꯁꯤꯡ, ꯄꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯔꯤꯖꯁꯤꯡ" ("drainage channels, ponds, canals, bunds and ridges") ꯑꯁꯤ ꯃꯁꯤꯒꯤ ꯁꯔꯨꯛ ꯑꯣꯏꯅꯥ ꯂꯧꯏ꯫ ꯁ꯭ꯀ꯭ꯔꯤꯟꯁꯤꯡꯅꯥ ꯐꯨꯝꯗꯤ ꯑꯃꯁꯨꯡ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡ ꯃꯄꯨꯟꯍꯜꯂꯤꯕ ꯋꯦꯁ꯭ꯠ ꯑꯗꯨ ꯌꯦꯡꯁꯤꯜꯂꯤ: ꯀꯩꯊꯦꯜꯒꯤ ꯋꯦꯁ꯭ꯠ ꯑꯁꯤ ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥꯗ ꯊꯥꯗꯣꯀꯏ, "ꯃꯁꯤꯅꯥ ꯆꯍꯤ ꯄꯨꯝꯕꯗ ꯆꯦꯟꯗꯕ ꯏꯁꯤꯡ ꯄꯨꯟꯁꯤꯟꯕ ꯑꯃꯥ ꯁꯦꯝꯃꯤ" ("which creates a stagnant pool all along the year") (ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ)꯫ ꯇꯣꯉꯥꯟꯅꯥ ꯊꯝꯕ ꯃꯁꯥꯃꯛ ꯑꯁꯤ ꯁꯥꯏꯠ ꯈꯨꯗꯤꯡꯃꯛꯅꯥ ꯅꯠꯇꯅꯥ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯄ꯭ꯂꯥꯟ ꯇꯧꯒꯗꯕꯅꯤ꯫
ꯑꯅꯤꯁꯨꯕꯗꯤ ꯆꯤꯡꯁꯤꯡꯅꯤ꯫ ꯗꯤꯁꯥꯡ ꯁꯦꯜꯅꯥ "ꯆꯤꯡꯒꯤ ꯂꯝꯒꯤ ꯆꯥꯡ 85 p.c. ꯃꯔꯣꯜ ꯂꯧꯏ, ꯏꯟꯐꯤꯜꯇ꯭ꯔꯦꯁꯟ ꯍꯟꯊꯕ ꯑꯃꯁꯨꯡ ꯔꯟꯑꯣꯐ ꯍꯦꯟꯕ" ("occupies almost 85 p.c. of the hilly region, have less infiltration and more run off"); ꯐꯠꯇꯕ ꯑꯣꯏꯔꯕ ꯂꯝꯅꯥ 1,545 km² ꯌꯥꯎꯏ, ꯇꯝꯄꯥꯛꯀꯤ ꯀꯦꯆꯃꯦꯟꯠꯀꯤ 24% ꯑꯃꯁꯨꯡ ꯃꯁꯤꯒꯤ ꯆꯤꯡꯁꯤꯡꯒꯤ 35%, ꯑꯃꯁꯨꯡ ꯋꯥꯡꯕ ꯑꯃꯁꯨꯡ ꯃꯌꯥꯏꯗꯒꯤ-ꯋꯥꯡꯕ ꯏꯔꯣꯖꯟꯒꯤ ꯀ꯭ꯂꯥꯁꯁꯤꯡꯅꯥ ꯁ꯭ꯇꯗꯤ ꯇꯧꯈꯤꯕ ꯑꯦꯔꯤꯌꯥꯒꯤ 51% ꯌꯥꯎꯏ (MASTEC)꯫ ꯅꯥꯄꯣꯝꯁꯤꯡ ꯑꯁꯤ ꯀꯛꯂꯕ ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡꯅꯥ ꯊꯨꯝꯂꯕ ꯃꯇꯝꯗ ꯂꯥꯟꯊꯔꯀꯏ: 30 ꯖꯨꯟ 2022-ꯗ (ꯔꯤꯄꯣꯔꯠ ꯈꯔꯗ 29 ꯖꯨꯟ) ꯇꯨꯄꯨꯜꯗ (Tupul) (ꯅꯣꯅꯦ), ꯖꯤꯔꯤꯕꯥꯝ–ꯏꯝꯐꯥꯜ ꯔꯦꯜꯋꯦꯒꯤ ꯁꯥꯏꯠꯇ ꯊꯣꯛꯈꯤꯕ ꯂꯦꯟꯗꯁ꯭ꯂꯥꯏꯗ ꯑꯗꯨꯅꯥ ꯇꯣꯉꯥꯟꯕ ꯃꯁꯤꯡ ꯃꯇꯨꯡ ꯏꯟꯅ ꯃꯤ 56, 58 ꯅꯠꯔꯒꯥ 61 ꯁꯤꯍꯟꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ; NRSC-ꯒꯤ 5 ꯖꯨꯂꯥꯏꯒꯤ ꯅꯣꯠꯅꯥ ꯁꯤꯈꯤꯕ 42 ꯑꯃꯁꯨꯡ ꯃꯥꯡꯈꯤꯕ 20 ꯄꯤꯈꯤ, ꯀꯣꯠꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ), ꯑꯃꯁꯨꯡ ꯁ꯭ꯇꯗꯤ ꯑꯃꯅꯥ ꯃꯁꯤ "ꯐꯅꯥ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯗꯕ ꯅꯠꯔꯒꯥ ꯐꯅꯥ ꯇꯧꯗꯕ ꯅꯥꯄꯣꯝ ꯇꯨꯝꯊꯣꯀꯄ ꯑꯃꯁꯨꯡ ꯀꯟꯅꯥ ꯆꯨꯕ ꯅꯣꯡ" ("poorly designed or implemented slope excavation coupled with heavy rainfall")-ꯒꯤ ꯃꯔꯝꯅꯤ ꯍꯥꯌꯔꯤ (Baruah et al., 2023, AGU Landslide Blog-ꯒꯤ ꯁꯔꯆ ꯁꯝꯃꯔꯤ ꯑꯃꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ); 1 ꯑꯒꯁ꯭ꯠ 2015-ꯗ ꯖꯧꯃꯣꯜꯗ (Joumol) (ꯆꯥꯟꯗꯦꯜ) ꯊꯣꯛꯈꯤꯕ ꯂꯦꯟꯗꯁ꯭ꯂꯥꯏꯗ ꯑꯗꯨꯅꯥ ꯃꯤ 20 ꯅꯠꯔꯒꯥ 21, ꯅꯠꯔꯒꯥ ActionAid-ꯒꯤ ꯃꯁꯤꯡ ꯃꯇꯨꯡ ꯏꯟꯅ 24, ꯁꯤꯍꯟꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ)꯫ ꯆꯤꯡꯒꯤ ꯁ꯭ꯇ꯭ꯔꯤꯝꯁꯤꯡꯅꯥ ꯇꯝꯄꯥꯛꯀꯤ ꯂꯝ ꯑꯃꯁꯨꯡ ꯂꯣꯛꯇꯥꯛꯇ ꯌꯧꯕ ꯃꯐꯝꯗ ꯃꯈꯣꯌꯒꯤ ꯄꯣꯠꯂꯨꯝ ꯊꯥꯗꯣꯀꯏ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯃꯤꯠꯌꯦꯡ (m)-ꯅꯥ ꯆꯤꯡ–ꯇꯝꯄꯥꯛꯀꯤ ꯈꯥꯌꯗꯣꯛꯐꯝꯗ ꯁꯤꯜꯠ ꯇ꯭ꯔꯦꯞ ꯑꯃꯥ ꯊꯝꯂꯤ: ꯃꯈꯣꯌꯅꯥ "ꯂꯣꯛꯇꯥꯛ ꯂꯦꯛꯇ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯂꯝꯕꯤ ꯈꯔꯒꯤꯗꯃꯛ ꯑꯉꯃꯕ ꯅꯥꯄꯣꯝꯗ ꯆꯦꯟꯊꯔꯀꯏ … ꯄꯣꯠꯂꯨꯝ ꯄꯨꯕꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯋꯥꯡꯏ, ꯃꯁꯤꯅꯥ ꯂꯦꯛ ꯑꯗꯨꯗ ꯂꯩꯃꯨ ꯊꯨꯗꯣꯛꯍꯜꯂꯤ" ("flow down with steep slope for a short distance before meeting the Loktak Lake … load carrying capacity is high which causes siltation of the lake") (MASTEC)꯫ ꯔꯤꯁꯔꯆꯀꯤ ꯃꯇꯝꯗ ꯗꯦꯕ꯭ꯔꯤꯁ, ꯕꯜꯀꯤꯡ ꯅꯠꯔꯒꯥ ꯕ꯭ꯂꯣꯀꯦꯖꯒꯤꯗꯃꯛ ꯃꯅꯤꯄꯨꯔꯒꯤ ꯑꯦꯂꯥꯎꯑꯦꯟꯁ ꯑꯃꯠꯇꯥ ꯐꯡꯈꯤꯗꯦ [TBC], ꯑꯃꯁꯨꯡ ꯕꯜꯀꯤꯡ ꯐꯦꯛꯇꯔꯁꯤꯡ, ꯗꯦꯕ꯭ꯔꯤꯁ ꯔꯦꯛꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯗꯦꯕ꯭ꯔꯤꯁ ꯕꯦꯁꯤꯟꯁꯤꯡꯒꯤ ꯃꯇꯥꯡꯗ ꯏꯟꯗꯤꯌꯥꯒꯤ ꯒꯥꯏꯗꯦꯟꯁ ꯑꯃꯠꯇꯥ ꯐꯡꯈꯤꯗꯦ [TBC], ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯃꯤꯠꯌꯦꯡ (f)-ꯗꯒꯤ (m) ꯐꯥꯎꯕꯒꯤ ꯃꯁꯤꯡ ꯈꯨꯗꯤꯡꯃꯛ ꯁꯦꯔꯤꯖ ꯑꯁꯤꯒꯤ ꯆꯤꯡ ꯑꯃꯁꯨꯡ ꯆꯤꯡ ꯑꯆꯧꯕꯒꯤ ꯑꯦꯗꯤꯁꯟꯁꯤꯡꯒꯤ ꯃꯔꯛꯀꯤ ꯚꯦꯜꯌꯨꯅꯤ, ꯃꯔꯝ ꯑꯗꯨꯃꯛꯀꯥ ꯂꯣꯌꯅꯅ꯫ ꯗꯦꯕ꯭ꯔꯤꯁ ꯔꯦꯛ ꯑꯃꯒꯤꯗꯃꯛ 1 ha-ꯒꯤ ꯇ꯭ꯔꯤꯒꯔ ꯑꯁꯤꯅꯥ ꯆꯤꯡꯒꯤ ꯅꯥꯄꯣꯝꯁꯤꯡꯗ ꯃꯤꯅꯤꯠ ꯈꯔꯒꯤ ꯇꯥꯏꯝ ꯑꯣꯐ ꯀꯟꯁꯦꯟꯇ꯭ꯔꯦꯁꯟ ꯎꯠꯂꯤ꯫ 1.25-ꯒꯤ ꯕꯜꯀꯤꯡ ꯐꯦꯛꯇꯔ ꯑꯁꯤ ꯃꯁꯤꯒꯤ ꯚꯣꯂꯨꯝꯒꯤ ꯁꯔꯨꯛ ꯃꯉꯥꯒꯤ ꯑꯃꯥ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯣꯏꯅꯥ ꯄꯨꯕ ꯐ꯭ꯂꯣ ꯑꯃꯒꯤ ꯐꯦꯛꯇꯔꯅꯤ (ꯕꯜꯀꯤꯡ ꯐꯦꯛꯇꯔ = 1 / (1 − ꯚꯣꯂꯨꯝꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯐ꯭ꯔꯦꯛꯁꯟ)), ꯃꯁꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯅꯥ ꯄꯨꯕ ꯉꯝꯕ ꯑꯃꯁꯨꯡ ꯍꯧꯖꯤꯛꯁꯨ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯨꯝꯅꯥ ꯆꯠꯄ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯍꯦꯟꯕ ꯃꯔꯣꯜꯅꯤ; ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯂꯩꯕ ꯐ꯭ꯂꯣ ꯑꯃꯅꯥ ꯗꯦꯕ꯭ꯔꯤꯁ ꯐ꯭ꯂꯣꯒꯨꯝꯅꯥ ꯆꯠꯏ, ꯃꯁꯤꯒꯤꯗꯃꯛ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯠꯇꯥ ꯁꯥꯏꯖ ꯂꯦꯞꯄ ꯌꯥꯗꯦ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯃꯤꯠꯌꯦꯡ (g)-ꯅꯥ ꯕꯤꯜꯗꯤꯡꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯥꯎꯠꯐꯣꯜꯁꯤꯡ ꯃꯁꯤꯒꯤ ꯂꯝꯕꯤꯗꯒꯤ ꯂꯥꯞꯅꯥ ꯊꯝꯃꯤ꯫ ꯃꯤꯠꯌꯦꯡ (h)-ꯒꯤ 3.0 m-ꯒꯤ ꯂꯤꯃꯤꯠ ꯑꯁꯤꯅꯥ ꯀꯣꯔ ꯑꯗꯨꯒꯤ 1.5 m ꯑꯗꯨ ꯑꯅꯤ ꯊꯣꯛ ꯍꯦꯟꯒꯠꯍꯜꯂꯤ, ꯃꯔꯝꯗꯤ ꯅꯨꯡꯁꯤꯡ, ꯎꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯋꯦꯁ꯭ꯠꯅꯥ ꯎꯃꯅꯥ ꯈꯛꯇꯅꯥ ꯊꯤꯡꯗꯕ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡ ꯊꯤꯡꯏ꯫ ꯃꯤꯠꯌꯦꯡ (i)-ꯒꯤ 1.0 m/s-ꯒꯤ ꯃꯤꯅꯤꯃꯝ ꯑꯁꯤꯅꯥ CPHEEO-ꯒꯤ 0.6 m/s, ꯃꯁꯤ 0.09 mm-ꯒꯤ ꯃꯄꯤꯛ ꯂꯩꯉꯣꯏ ꯄꯨꯕꯗ ꯌꯨꯝꯐꯝ ꯑꯣꯏꯕ, ꯃꯗꯨꯒꯤ ꯃꯍꯨꯠ ꯁꯤꯜꯂꯤ, ꯃꯔꯝꯗꯤ ꯆꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯅꯥ ꯅꯨꯡꯀꯨꯞ ꯄꯨꯏ꯫ ꯃꯤꯠꯌꯦꯡ (f)-ꯒꯤ ꯃꯇꯝꯒꯤ ꯃꯌꯥꯏꯒꯤ ꯁꯦꯡꯗꯣꯀꯄ ꯑꯁꯤ ꯁꯦꯔꯤꯖ ꯑꯁꯤꯒꯤ ꯑꯇꯣꯞꯄ ꯅꯣꯔꯊ-ꯏꯁ꯭ꯠ ꯑꯦꯗꯤꯁꯟꯁꯤꯡꯗ ꯂꯩꯕꯒꯨꯝꯅꯥ 31 ꯃꯦꯗ ꯅꯠꯇꯅꯥ 15 ꯃꯦꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯇꯧꯒꯗꯕꯅꯤ, ꯃꯔꯝꯗꯤ 2024 ꯑꯃꯁꯨꯡ 2025-ꯒꯤ ꯇꯝꯄꯥꯛꯀꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯁꯤꯡ ꯃꯦꯒꯤ ꯑꯔꯣꯏꯕꯗ ꯂꯥꯛꯈꯤ꯫ IRC:SP:42-2014 (cl. 8.5.1)-ꯅꯥ ꯆꯤꯡꯒꯤ ꯂꯝꯕꯤꯁꯤꯡ ꯃꯃꯥꯡꯗꯒꯤ ꯇꯣꯉꯥꯟꯅꯥ ꯂꯧꯏ, ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯁꯥꯏꯗ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ "ꯐꯥꯔꯕ ꯂꯝꯁꯤꯡꯗ ꯂꯩꯕꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯅꯛꯅꯕ ꯂꯥꯞ ꯊꯥꯛꯇ" ("at closer intervals compared to those in plain areas") ꯀꯜꯚꯔꯠꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ, ꯑꯃꯁꯨꯡ ꯃꯤꯠꯌꯦꯡ (k)-ꯅꯥ ꯂꯝꯕꯤꯒꯤ ꯔꯟꯑꯣꯐ ꯑꯁꯤ ꯉꯥꯛꯊꯣꯛꯇꯕ ꯅꯥꯄꯣꯝꯁꯤꯡꯗꯒꯤ ꯂꯥꯞꯅꯥ ꯊꯝꯃꯤ, ꯃꯔꯝꯗꯤ ꯅꯥꯄꯣꯝ ꯑꯃꯗ ꯊꯥꯗꯣꯀꯄ ꯏꯁꯤꯡꯅꯥ ꯃꯁꯤꯒꯤ ꯄꯣꯔ ꯄ꯭ꯔꯦꯁꯔ ꯍꯦꯟꯒꯠꯍꯜꯂꯤ (ꯀ꯭ꯂꯣꯖ 4.11); ꯃꯤꯠꯌꯦꯡ (l)-ꯒꯤ ꯋꯤꯞ ꯄꯥꯏꯞꯁꯤꯡꯅꯥ ꯋꯣꯜ ꯑꯃꯒꯤ ꯃꯇꯨꯡꯗ ꯂꯩꯕ ꯏꯁꯤꯡꯒꯤꯗꯃꯛ ꯃꯗꯨꯃꯛ ꯇꯧꯏ꯫ IMC 2024-ꯒꯤ ꯗ꯭ꯔꯥꯐꯠꯀꯤ ꯅꯥꯄꯣꯝꯒꯤ ꯀ꯭ꯂꯥꯁꯁꯤꯡꯅꯥ ꯕꯤꯜꯗꯤꯡ ꯁꯥꯕ ꯑꯃꯁꯨꯡ ꯀꯛꯄ ꯂꯦꯞꯄ ꯃꯐꯝ ꯃꯃꯥꯡꯗꯒꯤ ꯊꯝꯂꯤ; ꯃꯤꯠꯌꯦꯡ (l) ꯑꯃꯁꯨꯡ (m)-ꯅꯥ ꯃꯈꯣꯌꯒꯥ ꯂꯣꯌꯅꯅ ꯆꯠꯄ ꯏꯔꯝꯗ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤ ꯃꯁꯥꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯑꯃꯥ ꯄꯤꯔꯤ꯫ ꯀ꯭ꯂꯣꯖ ꯑꯁꯤꯅꯥ ꯈꯣꯡꯕꯥꯟꯗ ꯂꯩꯕ ꯁꯤꯋꯦꯖ, ꯂꯩꯃꯨ ꯑꯃꯁꯨꯡ ꯗꯦꯕ꯭ꯔꯤꯁꯀꯤ ꯃꯇꯥꯡꯗ ꯌꯦꯡꯏ; ꯃꯁꯤꯅꯥ ꯈꯣꯡꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡꯒꯤ ꯀꯟꯀ꯭ꯔꯤꯠ ꯆꯦꯅꯦꯂꯥꯏꯖꯦꯁꯟ ꯍꯥꯌꯖꯗꯦ, ꯃꯈꯣꯌꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯁꯤ ꯔꯐꯅꯦꯁꯀꯤ ꯃꯔꯝꯅꯥ ꯅꯠꯇꯅꯥ ꯂꯝ ꯈꯣꯞꯄ, ꯋꯦꯁ꯭ꯠ ꯊꯥꯗꯣꯀꯄ ꯑꯃꯁꯨꯡ ꯐꯤꯜ ꯇꯧꯕꯅꯥ ꯃꯥꯡꯈ꯭ꯔꯦ꯫
6.4 ꯗꯤꯖꯥꯏꯟ ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗꯁꯤꯡ
6.4.1 ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ, ꯂꯝꯕꯤꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡ ꯑꯁꯤ ꯇꯦꯕꯜ 6.1-ꯒꯤ AEP-ꯁꯤꯡꯒꯤꯗꯃꯛ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ꯫ ꯑꯦꯂꯤꯃꯦꯟꯠ ꯑꯃꯗ ꯂꯝ ꯁꯤꯖꯤꯟꯅꯕꯒꯤ ꯔꯣ ꯑꯃꯁꯨꯡ ꯂꯝꯕꯤꯒꯤ ꯀ꯭ꯂꯥꯁꯀꯤ ꯔꯣ ꯑꯅꯤꯃꯛ ꯆꯠꯅꯔꯕ ꯃꯐꯝꯗ, ꯍꯦꯟꯅꯥ ꯌꯥꯝꯗꯅꯥ ꯊꯣꯀꯄ AEP (ꯍꯦꯟꯅꯥ ꯁꯥꯡꯕ ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗ) ꯑꯗꯨꯅꯥ ꯂꯩꯉꯥꯀꯏ꯫
ꯇꯦꯕꯜ 6.1 — ꯀꯟꯚꯦꯌꯦꯟꯁꯀꯤ ꯗꯤꯖꯥꯏꯟ AEP-ꯁꯤꯡ (ꯀ꯭ꯂꯣꯖ 2.4-ꯒꯥ ꯃꯥꯟꯅꯩ)
| ꯑꯦꯂꯤꯃꯦꯟꯠ | ꯗꯤꯖꯥꯏꯟ AEP (ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗ) | ꯆꯦꯛ ꯏꯚꯦꯟꯠ | ꯌꯨꯝꯐꯝ |
|---|---|---|---|
| ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ: ꯏꯝꯐꯥꯜ, ꯊꯧꯕꯥꯜ, ꯀꯛꯆꯤꯡ, ꯕꯤꯁ꯭ꯅꯨꯄꯨꯔ ꯑꯃꯁꯨꯡ ꯆꯨꯔꯆꯥꯟꯗꯄꯨꯔꯒꯤ ꯀꯣꯔ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯍꯥꯏ-ꯗꯦꯟꯁꯤꯇꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡ | 10% (10-yr) | 1% (100-yr) ꯑꯣꯚꯔꯂꯦꯟꯗ ꯂꯝꯕꯤ | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ (ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ ꯌꯦꯡꯕꯤꯌꯨ) |
| ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ: ꯑꯇꯣꯞꯄ ꯀ꯭ꯂꯥꯁ I ꯑꯦꯔꯤꯌꯥꯁꯤꯡ | 20% (5-yr) | 1% ꯑꯣꯚꯔꯂꯦꯟꯗ ꯂꯝꯕꯤ | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ; CPHEEO Table 4.1 |
| ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ: ꯑꯇꯣꯞꯄ ꯑꯦꯔꯤꯌꯥꯁꯤꯡ | 50% (2-yr) | 1% ꯑꯣꯚꯔꯂꯦꯟꯗ ꯂꯝꯕꯤ | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ; CPHEEO Table 4.1 |
| ꯑꯥꯔꯇꯤꯔꯤꯌꯦꯜ ꯂꯝꯕꯤꯒꯤ ꯏꯔꯝ ꯑꯃꯁꯨꯡ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡ | ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯏꯚꯦꯀꯨꯌꯦꯁꯟ ꯅꯠꯔꯒꯥ ꯏꯃꯔꯖꯦꯟꯁꯤ ꯔꯨꯠ ꯑꯣꯏꯕ ꯑꯥꯔꯇꯤꯔꯤꯌꯦꯜꯁꯤꯡꯒꯤꯗꯃꯛ 2% (50-yr); ꯑꯇꯣꯞꯄ ꯑꯥꯔꯇꯤꯔꯤꯌꯦꯜꯁꯤꯡꯒꯤꯗꯃꯛ 4% (25-yr) | ꯃꯊꯡꯒꯤ ꯍꯦꯟꯅꯥ ꯌꯥꯝꯗꯕ AEP: 2%-ꯒꯤ ꯗꯤꯖꯥꯏꯟꯒꯤꯗꯃꯛ 1%; 4%-ꯒꯤ ꯗꯤꯖꯥꯏꯟꯒꯤꯗꯃꯛ 2% | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ (25–50-yr); ꯈꯥꯌꯗꯣꯀꯄ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕ |
| ꯀꯂꯦꯛꯇꯔ ꯂꯝꯕꯤꯒꯤ ꯏꯔꯝ ꯑꯃꯁꯨꯡ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡ | 4% (25-yr) | 2% (50-yr) | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ |
| ꯂꯣꯀꯦꯜ ꯂꯝꯕꯤꯒꯤ ꯏꯔꯝ ꯑꯃꯁꯨꯡ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡ | 10% (10-yr) | 4% (25-yr) | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ |
| ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯂꯩꯕ ꯔꯣꯗ ꯑꯟꯗꯔꯄꯥꯁꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯇ꯭ꯔꯦꯞ ꯇꯧꯔꯕ ꯁꯦꯒꯁꯤꯡ | 2% (50-yr) | 1% (100-yr) | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ (ꯀ꯭ꯂꯣꯖ 6.10.5) |
| ꯑꯦꯌꯥꯔꯄꯣꯔꯇꯁꯤꯡ, ꯔꯦꯜꯋꯦ ꯁ꯭ꯇꯦꯁꯟꯁꯤꯡ, ꯄꯥꯋꯔ ꯁ꯭ꯇꯦꯁꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯃꯔꯨꯑꯣꯏꯕ ꯏꯟꯐ꯭ꯔꯥꯁ꯭ꯇ꯭ꯔꯛꯆꯔ | ꯀ꯭ꯂꯥꯁ I ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯗ 1% (100-yr); ꯑꯇꯣꯞꯄ ꯃꯐꯝꯁꯤꯡꯗ 2% (50-yr) | — | CPHEEO 2019 Table 4.1 |
| ꯃꯦꯖꯔ (ꯑꯣꯚꯔꯂꯦꯟꯗ) ꯁꯤꯁ꯭ꯇꯦꯝ, ꯑꯦꯂꯤꯃꯦꯟꯠ ꯈꯨꯗꯤꯡꯃꯛ | 1% (100-yr) | — | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ |
| ꯕꯤꯜꯗꯤꯡꯒꯤ ꯐ꯭ꯂꯣꯔ ꯂꯦꯚꯦꯜꯁꯤꯡ | 1%-ꯒꯤ ꯂꯦꯚꯦꯜ + 0.5 m ꯐ꯭ꯔꯤꯕꯣꯔꯗ | — | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤ (ꯀ꯭ꯂꯣꯖ 6.11) |
6.4.2 ꯆꯦꯛ ꯏꯚꯦꯟꯠꯁꯤꯡ. ꯇꯦꯕꯜ 6.1-ꯒꯤ ꯆꯦꯛ ꯏꯚꯦꯟꯠꯇ, ꯃꯥꯏꯅꯔ ꯑꯃꯁꯨꯡ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯄꯨꯟꯅꯕꯅꯥ ꯆꯦꯛ-ꯏꯚꯦꯟꯠꯀꯤ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯇꯦꯕꯜ 6.2-ꯒꯤ 1% AEP-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ ꯑꯃꯁꯨꯡ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯠꯇꯗ ꯏꯁꯤꯡ ꯆꯡꯗꯅꯥ ꯄꯨꯒꯗꯕꯅꯤ꯫ ꯀ꯭ꯂꯣꯖ 6.3.2-ꯒꯤ 1% ꯑꯣꯚꯔꯂꯦꯟꯗ ꯂꯝꯕꯤꯒꯤ ꯃꯊꯧ ꯇꯥꯕ ꯑꯁꯤ ꯆꯦꯛ ꯏꯚꯦꯟꯠꯀꯤ ꯃꯊꯛꯇ ꯍꯦꯟꯅꯥ ꯆꯠꯅꯩ꯫
6.4.3 ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕ ꯁ꯭ꯇꯦꯟꯗꯔꯗꯁꯤꯡ. ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤ ꯑꯃꯅꯥ ꯑꯦꯂꯤꯃꯦꯟꯠ ꯑꯃꯍꯦꯛꯇꯒꯤꯗꯃꯛ ꯍꯦꯟꯅꯥ ꯌꯥꯝꯗꯅꯥ ꯊꯣꯀꯄ AEP ꯑꯃꯥ ꯂꯧꯕ ꯌꯥꯏ, CPHEEO Table 4.1-ꯒꯤ Note 2-ꯗ ꯂꯩꯕ ꯍꯥꯏ-ꯄꯥꯋꯔ ꯀꯃꯤꯇꯤꯒꯤ ꯂꯝꯕꯤꯒꯤ ꯈꯨꯠꯊꯥꯡꯗꯁꯨ꯫ ꯃꯁꯤꯅꯥ ꯇꯦꯕꯜ 6.1-ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯌꯥꯝꯅꯥ ꯊꯣꯀꯄ AEP ꯑꯃꯥ ꯂꯧꯔꯣꯏꯗꯕꯅꯤ꯫
6.4.4 ꯍꯥꯏ-ꯗꯦꯟꯁꯤꯇꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡ. ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ 10% AEP-ꯒꯤ ꯃꯥꯏꯅꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯆꯠꯅꯕ ꯍꯥꯏ-ꯗꯦꯟꯁꯤꯇꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡ ꯑꯁꯤ ꯃꯦꯞ ꯑꯃꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯒꯗꯕꯅꯤ꯫ ꯃꯁꯤ ꯇꯧꯗ꯭ꯔꯤꯐꯥꯎꯕ, 10% AEP-ꯒꯤ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯑꯁꯤ ꯃꯈꯥꯒꯤꯁꯤꯡꯗ ꯆꯠꯅꯩ:
- (a) ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯗ, ꯍꯧꯔꯛꯐꯝꯁꯤꯡꯅꯥ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡ ꯊꯨꯝꯗꯕꯒꯤꯗꯃꯛ (waterlogging) ꯃꯃꯤꯡ ꯂꯧꯔꯤꯕ ꯂꯩꯀꯥꯏꯁꯤꯡ: ꯖꯨꯂꯥꯏ 2024-ꯗ ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥ ꯀꯨꯞꯂꯕ ꯃꯇꯝꯗ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯄꯨꯔꯛꯈꯤꯕ ꯅꯥꯒꯥꯔꯝ (Nagaram), ꯂꯥꯏꯐꯝ ꯈꯨꯅꯧ (Laipham Khunou) ꯑꯃꯁꯨꯡ ꯂꯥꯏꯔꯤꯛꯌꯦꯡꯕꯝ ꯂꯩꯀꯥꯏ, ꯑꯃꯁꯨꯡ 2024 ꯑꯃꯁꯨꯡ 2025-ꯗ ꯁꯤꯡꯖꯃꯩ, ꯍꯩꯉꯥꯡ (Heingang), ꯕꯥꯁꯤꯈꯣꯡ (Bashikhong), ꯅ꯭ꯌꯨ ꯆꯦꯀꯣꯟ (New Checkon), ꯀꯩꯔꯥꯡ (Keirang), ꯈꯥꯕꯝ (Khabam) ꯑꯃꯁꯨꯡ ꯀ꯭ꯁꯦꯇ꯭ꯔꯤ ꯑꯋꯥꯡ ꯂꯩꯀꯥꯏꯗ (Kshetri Awang Leikai) ꯄꯟ ꯀꯛꯈꯤꯕꯒꯤ ꯃꯇꯨꯡꯗ ꯂꯩꯕ ꯂꯩꯀꯥꯏꯁꯤꯡ (ꯄꯨꯝꯅꯃꯛ ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ); TPD-ꯅꯥ ꯂꯣꯀꯦꯜ ꯑꯦꯔꯤꯌꯥ ꯄ꯭ꯂꯥꯟꯒꯤ ꯁꯥꯏꯠ ꯑꯣꯏꯅꯥ ꯃꯃꯤꯡ ꯂꯧꯔꯤꯕ ꯏꯝꯐꯥꯜꯒꯤ ꯃꯌꯥꯏꯒꯤ ꯑꯦꯔꯤꯌꯥ 150 ha ꯃꯔꯣꯜ (TPD Annual Administrative Report 2025-26); ꯑꯃꯁꯨꯡ ꯁ꯭ꯃꯥꯔꯠ ꯁꯤꯇꯤꯒꯤ ꯑꯦꯔꯤꯌꯥ-ꯕꯦꯖ ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯑꯦꯔꯤꯌꯥꯗ ꯂꯩꯕ ꯊꯥꯡꯒꯜ (Thangal) ꯑꯃꯁꯨꯡ ꯄꯥꯎꯅꯥ ꯕꯖꯥꯔ (Paona Bazar) (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ) [TBC]; ꯃꯈꯣꯌ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯉꯃꯈꯩ ꯑꯁꯤ IMC ꯑꯃꯁꯨꯡ PDA Manipur-ꯅꯥ ꯀꯟꯐꯥꯔꯝ ꯇꯧꯒꯗꯕꯅꯤ [TBC];
- (b) ꯑꯇꯣꯞꯄ ꯎꯔꯕꯟ ꯂꯣꯀꯜ ꯕꯣꯗꯤ ꯑꯃꯁꯨꯡ ꯄ꯭ꯂꯥꯅꯤꯡ ꯑꯦꯔꯤꯌꯥ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯆꯠꯅꯔꯤꯕ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯅꯥ ꯀꯣꯔ ꯑꯦꯔꯤꯌꯥ, ꯑꯔꯤꯕ ꯁꯍꯔ ꯅꯠꯔꯒꯥ ꯁꯦꯟꯇ꯭ꯔꯦꯜ ꯕꯤꯖꯤꯅꯦꯁ ꯗꯤꯁ꯭ꯇ꯭ꯔꯤꯛ ꯑꯣꯏꯅꯥ ꯈꯡꯗꯣꯛꯂꯤꯕ ꯑꯦꯔꯤꯌꯥ, ꯑꯃꯁꯨꯡ ꯁꯍꯔ ꯑꯃꯒꯤ ꯃꯔꯨꯑꯣꯏꯕ ꯀꯩꯊꯦꯜ; ꯑꯃꯁꯨꯡ
- (c) ꯇꯤꯌꯔ A ꯕꯣꯗꯤ ꯑꯃꯗ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯅꯥ ꯖꯣꯟ ꯑꯗꯨꯒꯤ ꯕꯦꯁ ꯚꯦꯜꯌꯨꯗꯒꯤ ꯍꯦꯟꯕ ꯐ꯭ꯂꯣꯔ ꯁ꯭ꯄꯦꯁ ꯏꯟꯗꯦꯛꯁ ꯌꯥꯍꯜꯂꯤꯕ ꯑꯦꯔꯤꯌꯥ ꯈꯨꯗꯤꯡꯃꯛ꯫
6.4.5 ꯔꯦꯇ꯭ꯔꯣꯐꯤꯠ (retrofit). ꯂꯩꯔꯤꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯇꯦꯕꯜ 6.1-ꯒꯤ AEP ꯐꯥꯎꯕ ꯆꯥꯎꯍꯟꯕ ꯉꯃꯗꯕ ꯃꯐꯝꯗ, ꯍꯟꯊꯔꯤꯕ ꯑꯗꯨ ꯃꯊꯛ ꯊꯡꯕ ꯃꯐꯝꯒꯤ ꯁ꯭ꯇꯣꯔꯦꯖ (ꯁꯔꯨꯛ 4), ꯔꯤꯖꯅꯦꯜ ꯁ꯭ꯇꯣꯔꯦꯖ (ꯁꯔꯨꯛ 7) ꯅꯠꯔꯒꯥ ꯐꯒꯠꯍꯜꯂꯕ ꯃꯦꯖꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯂꯝꯕꯤ ꯑꯃꯅꯥ ꯃꯄꯨꯡ ꯐꯥꯍꯅꯒꯗꯕꯅꯤ꯫ ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯂꯦꯃꯍꯧꯔꯤꯕ ꯂꯦꯚꯦꯜ ꯑꯣꯐ ꯁꯔꯚꯤꯁ ꯑꯗꯨ ꯔꯦꯀꯣꯔꯗ ꯇꯧꯒꯗꯕꯅꯤ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. ꯇꯦꯕꯜ 6.1-ꯒꯤ ꯚꯦꯜꯌꯨꯁꯤꯡ ꯑꯁꯤ ꯀ꯭ꯂꯣꯖ 2.4-ꯒꯤ ꯁꯝꯃꯔꯤꯒꯥ ꯃꯥꯟꯅꯩ ꯑꯃꯁꯨꯡ ꯑꯟꯗꯔꯄꯥꯁꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯃꯔꯨꯑꯣꯏꯕ ꯏꯟꯐ꯭ꯔꯥꯁ꯭ꯇ꯭ꯔꯛꯆꯔꯒꯤ ꯔꯣꯁꯤꯡ ꯍꯥꯄꯆꯤꯜꯂꯤ꯫ ꯃꯈꯣꯌ ꯑꯁꯤ ꯀ꯭ꯂꯥꯁ I ꯁꯍꯔꯁꯤꯡꯒꯤꯗꯃꯛ 5-yr ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯃꯐꯝꯁꯤꯡꯗ 2-yr-ꯒꯤ CPHEEO (2019)-ꯒꯤ ꯅꯦꯁꯅꯦꯜ ꯑꯦꯗꯚꯥꯏꯖꯔꯤ ꯃꯤꯅꯤꯃꯝꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯏ (CPHEEO Part A, Table 4.1)꯫ ꯇꯦꯕꯜ ꯑꯗꯨꯒꯤ Note 2-ꯅꯥ ꯁ꯭ꯇꯦꯠꯀꯤ ꯀꯃꯤꯇꯤ ꯑꯃꯅꯥ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕ ꯚꯦꯜꯌꯨꯁꯤꯡ ꯂꯧꯕ ꯌꯥꯍꯜꯂꯤ꯫ ꯍꯥꯏ-ꯗꯦꯟꯁꯤꯇꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯒꯤ 10-yr-ꯒꯤ ꯇꯤꯌꯔ ꯑꯁꯤ Gupta (IIT Bombay) ꯃꯇꯨꯡ ꯏꯟꯅꯔꯤ, ꯃꯍꯥꯛꯅꯥ "ꯔꯦꯁꯤꯗꯦꯟꯁꯤꯌꯦꯜ-ꯍꯥꯏ ꯗꯦꯟꯁꯤꯇꯤꯒꯤꯗꯃꯛ ꯆꯍꯤ 10-ꯗ 1" ("1 in 10 year for residential-high density") ꯄꯥꯎꯇꯥꯛ ꯄꯤꯔꯤ, ꯑꯃꯁꯨꯡ ꯃꯂꯦꯁꯤꯌꯥꯒꯤ MSMA 2, ꯃꯁꯤꯅꯥ ꯂꯤꯉ꯭ꯛ ꯍꯥꯎꯁꯁꯤꯡ, ꯑꯦꯄꯥꯔꯠꯃꯦꯟꯇꯁꯤꯡ, ꯀꯃꯔꯁꯤꯌꯦꯜ ꯑꯃꯁꯨꯡ ꯏꯟꯗꯁ꯭ꯇ꯭ꯔꯤꯌꯦꯜ ꯂꯝꯒꯤꯗꯃꯛ 10-yr-ꯒꯤ ꯃꯥꯏꯅꯔ ꯑꯃꯁꯨꯡ 100-yr-ꯒꯤ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯁꯤꯡ ꯁꯤꯖꯤꯟꯅꯩ꯫ ꯂꯝꯕꯤꯒꯤ ꯚꯦꯜꯌꯨꯁꯤꯡꯅꯥ ꯏꯟꯗꯤꯌꯥꯒꯤ ꯀꯣꯗꯁꯤꯡꯗ ꯂꯩꯕ ꯇꯣꯉꯥꯟꯅꯕ ꯑꯃꯥ ꯂꯣꯏꯁꯤꯜꯂꯤ꯫ IRC:SP:50-2013-ꯅꯥ ꯁꯍꯔꯒꯤ ꯂꯝꯕꯤꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤꯗꯃꯛ ꯆꯍꯤ 1–2 ꯄꯥꯎꯇꯥꯛ ꯄꯤꯔꯤ꯫ IRC:SP:42-2014-ꯅꯥ ꯁꯍꯔꯒꯤ ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤꯗꯃꯛ ꯆꯍꯤ 25 ꯑꯃꯁꯨꯡ ꯃꯊꯡꯒꯤ ꯍꯦꯟꯅꯥ ꯁꯥꯡꯕ ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗꯇ ꯆꯦꯛ ꯐ꯭ꯂꯗ (check flood) ꯑꯃꯥ ꯄꯥꯎꯇꯥꯛ ꯄꯤꯔꯤ꯫ APWA 5600 (2006)-ꯅꯥ ꯑꯥꯔꯇꯤꯔꯤꯌꯦꯜꯒꯤꯗꯃꯛ 50-yr, ꯀꯂꯦꯛꯇꯔꯒꯤꯗꯃꯛ 25-yr ꯑꯃꯁꯨꯡ ꯔꯦꯁꯤꯗꯦꯟꯁꯤꯌꯦꯜ ꯂꯝꯕꯤꯒꯤ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡꯒꯤꯗꯃꯛ 10-yr ꯁꯤꯖꯤꯟꯅꯩ꯫ ꯇꯦꯕꯜ 6.1-ꯅꯥ APWA-ꯒꯤ ꯇꯤꯌꯔꯁꯤꯡ ꯑꯃꯁꯨꯡ IRC:SP:42-ꯒꯤ ꯆꯦꯛ-ꯐ꯭ꯂꯗꯀꯤ ꯋꯥꯈꯜꯂꯣꯟ ꯂꯧꯔꯤ꯫ ꯑꯥꯔꯇꯤꯔꯤꯌꯦꯜꯁꯤꯡ ꯑꯁꯤ 50-yr-ꯒꯤ ꯏꯚꯦꯀꯨꯌꯦꯁꯟ ꯔꯨꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ 25-yr-ꯒꯤ ꯑꯇꯣꯞꯄꯁꯤꯡ ꯑꯣꯏꯅꯥ ꯈꯥꯌꯗꯣꯀꯄ ꯑꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯃꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ ꯑꯟꯗꯔꯄꯥꯁꯁꯤꯡꯒꯤ 50-yr-ꯒꯤ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯑꯁꯤꯁꯨ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ, ꯃꯔꯝꯗꯤ ꯑꯟꯗꯔꯄꯥꯁ ꯑꯃꯥ ꯇ꯭ꯔꯦꯞ ꯇꯧꯔꯕ ꯁꯦꯒ ꯑꯃꯅꯤ, ꯃꯐꯝ ꯑꯗꯨꯗ ꯐꯦꯜ ꯇꯧꯕꯒꯤ ꯃꯑꯣꯡꯗꯤ ꯒꯥꯔꯤ ꯆꯠꯂꯤꯕ ꯀꯦꯔꯤꯌꯦꯖꯋꯦ ꯑꯃꯗ ꯏꯁꯤꯡ ꯑꯏꯡꯕꯅꯤ꯫ ꯀ꯭ꯂꯣꯖ 6.4.4-ꯒꯤ ꯗꯤꯐꯣꯜꯠ ꯍꯥꯏ-ꯗꯦꯟꯁꯤꯇꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯃꯦꯞ ꯑꯃꯥ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯛꯠꯔꯤꯐꯥꯎꯕ ꯆꯠꯅꯩ꯫
6.5 ꯂꯝꯕꯤꯒꯤ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛꯁ: ꯁ꯭ꯞꯔꯦꯗ, ꯑꯏꯡꯕ ꯑꯃꯁꯨꯡ ꯐ꯭ꯂꯣꯒꯤ ꯍꯖꯥꯔꯗ
6.5.1 ꯒꯇꯔꯒꯤ ꯐ꯭ꯂꯣ. ꯇ꯭ꯔꯥꯏꯑꯦꯉ꯭ꯒꯨꯂꯔ ꯀꯔꯕ-ꯑꯃꯁꯨꯡ-ꯒꯇꯔ ꯁꯦꯛꯁꯟ ꯑꯃꯗ ꯂꯩꯕ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯃꯣꯗꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯃꯦꯅꯤꯡ (Izzard) ꯏꯀ꯭ꯋꯦꯁꯟꯅꯥ ꯊꯤꯒꯗꯕꯅꯤ:
Q = (Ku / n) · Sx^(5/3) · SL^(1/2) · T^(8/3)
ꯃꯐꯝ ꯑꯁꯤꯗ Q ꯑꯁꯤ ꯒꯇꯔꯒꯤ ꯐ꯭ꯂꯣ (m³/s), Ku = 0.376 (SI), n ꯑꯁꯤ ꯒꯇꯔꯒꯤ ꯃꯦꯅꯤꯡ ꯔꯐꯅꯦꯁ (ꯇꯦꯕꯜ 6.6), Sx ꯑꯁꯤ ꯀ꯭ꯔꯣꯁ ꯁ꯭ꯂꯣꯞ (m/m), SL ꯑꯁꯤ ꯂꯣꯉ꯭ꯒꯤꯇ꯭ꯌꯨꯗꯤꯅꯦꯜ ꯁ꯭ꯂꯣꯞ (m/m) ꯑꯃꯁꯨꯡ T ꯑꯁꯤ ꯁ꯭ꯞꯔꯦꯗ (m)꯫ ꯀꯝꯄꯣꯖꯤꯠ ꯑꯃꯁꯨꯡ ꯗꯤꯞꯔꯦꯁ ꯇꯧꯔꯕ ꯒꯇꯔ ꯁꯦꯛꯁꯟꯁꯤꯡ ꯑꯁꯤ FHWA HEC-22 (4th edition, 2024)-ꯒꯤ ꯊꯧꯑꯣꯡꯁꯤꯡꯅꯥ ꯑꯦꯅꯥꯂꯥꯏꯖ ꯇꯧꯒꯗꯕꯅꯤ꯫
6.5.2 ꯁ꯭ꯞꯔꯦꯗ ꯑꯃꯁꯨꯡ ꯑꯏꯡꯕꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ. ꯂꯝꯕꯤꯒꯤ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯇꯦꯕꯜ 6.2-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯂꯣꯏꯗꯕꯅꯤ꯫
ꯇꯦꯕꯜ 6.2 — ꯂꯝꯕꯤꯒꯤ ꯐ꯭ꯂꯣꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ
| ꯂꯝꯕꯤꯒꯤ ꯀ꯭ꯂꯥꯁ | ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯏꯚꯦꯟꯠ (ꯇꯦꯕꯜ 6.1) | ꯆꯦꯛ ꯏꯚꯦꯟꯠ ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯏꯚꯦꯟꯠ |
|---|---|---|
| ꯑꯥꯔꯇꯤꯔꯤꯌꯦꯜ | ꯁ꯭ꯞꯔꯦꯗꯅꯥ ꯃꯥꯏꯀꯩ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯊ꯭ꯔꯨ ꯂꯦꯟ ꯑꯃꯒꯤ ꯌꯥꯝꯗꯕꯗ ꯏꯁꯤꯡ ꯂꯩꯇꯅꯥ ꯊꯝꯒꯗꯕꯅꯤ꯫ ꯀ꯭ꯔꯥꯎꯟꯒꯤ ꯃꯊꯛꯇ ꯐ꯭ꯂꯣ ꯂꯩꯔꯣꯏ꯫ | ꯀ꯭ꯔꯥꯎꯟꯗ ꯑꯏꯡꯕ ≤ 150 mm ꯑꯃꯁꯨꯡ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯑꯏꯡꯕ ꯃꯐꯝꯗ ≤ 350 mm; ꯀ꯭ꯂꯣꯖ 6.5.3-ꯒꯤ ꯍꯖꯥꯔꯗꯀꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ |
| ꯀꯂꯦꯛꯇꯔ | ꯁ꯭ꯞꯔꯦꯗ T ≤ 3 m꯫ ꯁꯦꯒ ꯏꯟꯇꯔꯁꯦꯛꯁꯟ ꯑꯃꯗ ꯅꯠꯇꯕꯗꯤ ꯀ꯭ꯔꯥꯎꯟꯒꯤ ꯃꯊꯛꯇ ꯐ꯭ꯂꯣ ꯂꯩꯔꯣꯏ꯫ | ꯃꯊꯛꯇ ꯂꯩꯕꯒꯨꯝ |
| ꯂꯣꯀꯦꯜ | ꯁ꯭ꯞꯔꯦꯗ T ≤ 3 m꯫ ꯐ꯭ꯂꯣꯅꯥ ꯀꯔꯕꯀꯤ ꯃꯊꯛꯇ ꯆꯦꯟꯂꯣꯏꯗꯕꯅꯤ꯫ | ꯃꯊꯛꯇ ꯂꯩꯕꯒꯨꯝ |
| ꯀ꯭ꯂꯥꯁ ꯄꯨꯝꯅꯃꯛ, ꯏꯟꯇꯔꯁꯦꯛꯁꯟꯁꯤꯡꯗ | ꯁꯦꯒ ꯏꯟꯇꯔꯁꯦꯛꯁꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁꯨꯄꯔꯏꯂꯦꯚꯦꯁꯟ ꯇ꯭ꯔꯥꯟꯖꯤꯁꯟꯁꯤꯡꯗ ꯀ꯭ꯔꯥꯎꯟꯒꯤ ꯃꯊꯛꯇ ꯀ꯭ꯔꯣꯁ-ꯐ꯭ꯂꯣ ≤ 0.03 m³/s; ꯃꯤꯗ-ꯕ꯭ꯂꯣꯛ ꯁꯦꯒꯁꯤꯡꯗ ꯑꯃꯠꯇꯥ ꯂꯩꯔꯣꯏ꯫ | ꯃꯊꯛꯇ ꯂꯩꯕꯒꯨꯝ |
6.5.3 ꯐ꯭ꯂꯣꯒꯤ ꯍꯖꯥꯔꯗꯀꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ. ꯆꯦꯛ ꯏꯚꯦꯟꯠ ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯏꯚꯦꯟꯠꯇ, ꯂꯝꯕꯤ ꯑꯃꯁꯨꯡ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣꯒꯤ ꯑꯏꯡꯕ (D, m) ꯑꯃꯁꯨꯡ ꯚꯦꯂꯣꯁꯤꯇꯤꯒꯤ (V, m/s) ꯄ꯭ꯔꯣꯗꯛꯠ ꯑꯁꯤ ꯇꯦꯕꯜ 6.3-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯂꯣꯏꯗꯕꯅꯤ꯫
ꯇꯦꯕꯜ 6.3 — ꯂꯝꯕꯤꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯁꯤꯡꯒꯤ ꯐ꯭ꯂꯣꯒꯤ ꯍꯖꯥꯔꯗꯀꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ
| ꯃꯐꯝ | ꯃꯊꯧ ꯇꯥꯕ ꯍꯖꯥꯔꯗ ꯀ꯭ꯂꯥꯁ (ꯇꯦꯕꯜ 6.4) | ꯂꯤꯃꯤꯠꯁꯤꯡ |
|---|---|---|
| ꯂꯝꯕꯤ ꯄꯨꯝꯅꯃꯛꯀꯤ ꯀꯦꯔꯤꯌꯦꯖꯋꯦꯁꯤꯡ | H2 ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯐꯕ | D·V ≤ 0.6 m²/s; D ≤ 0.35 m (ꯇꯦꯕꯜ 6.2); V ≤ 2.0 m/s |
| ꯐꯨꯠꯄꯥꯊꯁꯤꯡ, ꯄꯦꯗꯦꯁ꯭ꯇ꯭ꯔꯤꯌꯟ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡ, ꯁ꯭ꯀꯨꯜ, ꯍꯣꯁꯄꯤꯇꯦꯜ ꯑꯃꯁꯨꯡ ꯇ꯭ꯔꯥꯟꯖꯤꯠ-ꯁ꯭ꯇꯣꯞꯀꯤ ꯃꯃꯥꯡꯁꯤꯡ | H1 | D·V ≤ 0.3 m²/s; D ≤ 0.3 m; V ≤ 2.0 m/s |
| ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯏꯚꯦꯀꯨꯌꯦꯁꯟ ꯑꯃꯁꯨꯡ ꯏꯃꯔꯖꯦꯟꯁꯤ ꯔꯨꯠꯁꯤꯡ | H1 | D·V ≤ 0.3 m²/s; D ≤ 0.3 m; V ≤ 2.0 m/s |
| ꯂꯝꯕꯤꯁꯤꯡꯗꯒꯤ ꯂꯥꯞꯅꯥ, ꯄꯕ꯭ꯂꯤꯛ ꯑꯣꯄꯟ ꯁ꯭ꯄꯦꯁ ꯅꯠꯔꯒꯥ ꯏꯖꯃꯦꯟꯠꯁꯤꯡꯗ ꯂꯩꯕ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯁꯤꯡ | H3 ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯐꯕ, ꯆꯦꯀꯁꯤꯅꯍꯟꯕꯒꯤ ꯁꯥꯏꯟꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ | D·V ≤ 0.6 m²/s; D ≤ 1.2 m; V ≤ 2.0 m/s |
ꯇꯦꯕꯜ 6.4 — ꯀꯝꯕꯥꯏꯟꯗ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯍꯖꯥꯔꯗ ꯚꯂꯅꯔꯦꯕꯤꯂꯤꯇꯤꯒꯤ ꯀ꯭ꯂꯥꯁꯁꯤꯡ (ꯔꯦꯐꯔꯦꯟꯁꯀꯤꯗꯃꯛ ꯑꯃꯨꯛ ꯍꯟꯅꯥ ꯄꯤꯔꯤ)
| ꯀ꯭ꯂꯥꯁ | ꯁꯟꯗꯣꯛꯄ | D·V-ꯒꯤ ꯂꯤꯃꯤꯠ (m²/s) | ꯑꯏꯡꯕꯒꯤ ꯂꯤꯃꯤꯠ D (m) | ꯚꯦꯂꯣꯁꯤꯇꯤꯒꯤ ꯂꯤꯃꯤꯠ V (m/s) |
|---|---|---|---|---|
| H1 | ꯃꯍꯧꯁꯥꯅꯥ ꯒꯥꯔꯤꯁꯤꯡ, ꯃꯤꯑꯣꯏꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯕꯤꯜꯗꯤꯡꯁꯤꯡꯒꯤꯗꯃꯛ ꯑꯁꯣꯏꯕ ꯂꯩꯇꯦ | ≤ 0.3 | 0.3 | 2.0 |
| H2 | ꯑꯄꯤꯛꯄ ꯒꯥꯔꯤꯁꯤꯡꯒꯤꯗꯃꯛ ꯑꯁꯣꯏꯕ ꯂꯩ | ≤ 0.6 | 0.5 | 2.0 |
| H3 | ꯒꯥꯔꯤꯁꯤꯡ, ꯑꯉꯥꯡꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯍꯜꯁꯤꯡꯒꯤꯗꯃꯛ ꯑꯁꯣꯏꯕ ꯂꯩ | ≤ 0.6 | 1.2 | 2.0 |
| H4 | ꯒꯥꯔꯤꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯃꯤꯑꯣꯏꯁꯤꯡꯒꯤꯗꯃꯛ ꯑꯁꯣꯏꯕ ꯂꯩ | ≤ 1.0 | 2.0 | 2.0 |
| H5 | ꯒꯥꯔꯤꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯃꯤꯑꯣꯏꯁꯤꯡꯒꯤꯗꯃꯛ ꯑꯁꯣꯏꯕ ꯂꯩ; ꯕꯤꯜꯗꯤꯡꯁꯤꯡꯗ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔꯦꯜ ꯃꯥꯡꯍꯟ ꯇꯥꯛꯍꯟꯕꯒꯤ ꯈꯨꯗꯣꯡꯆꯥꯕ ꯂꯩ | ≤ 4.0 | 4.0 | 4.0 |
| H6 | ꯒꯥꯔꯤꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯃꯤꯑꯣꯏꯁꯤꯡꯒꯤꯗꯃꯛ ꯑꯁꯣꯏꯕ ꯂꯩ; ꯕꯤꯜꯗꯤꯡ ꯄꯨꯝꯅꯃꯛ ꯂꯥꯟꯊꯔꯛꯄꯒꯤ ꯈꯨꯗꯣꯡꯆꯥꯕ ꯂꯩ | > 4.0 | — | — |
ꯍꯧꯔꯛꯐꯝ: AIDR Guideline 7-3, Technical flood risk management guideline: Flood hazard (2014), Tables 1 and 2, Smith and Wasko (2012)-ꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ ꯃꯣꯗꯦꯜ ꯇꯧꯔꯕ꯫
6.5.4 ꯀ꯭ꯂꯣꯖ 6.5.3-ꯒꯤꯗꯃꯛ ꯑꯏꯡꯕ ꯑꯃꯁꯨꯡ ꯚꯦꯂꯣꯁꯤꯇꯤ ꯑꯁꯤ ꯂꯥꯏꯕ ꯁꯦꯛꯁꯟꯁꯤꯡꯒꯤꯗꯃꯛ ꯒꯇꯔ-ꯐ꯭ꯂꯣꯒꯤ ꯀꯦꯜꯀꯨꯂꯦꯁꯟꯗꯒꯤ, ꯅꯠꯔꯒꯥ ꯐ꯭ꯂꯣꯅꯥ ꯀꯔꯕ-ꯑꯃꯁꯨꯡ-ꯒꯇꯔ ꯁꯦꯛꯁꯟ ꯊꯥꯗꯣꯛꯂꯕ ꯃꯐꯝꯗ 1D ꯅꯠꯔꯒꯥ 2D ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯃꯣꯗꯦꯜ ꯑꯃꯗꯒꯤ ꯂꯧꯒꯗꯕꯅꯤ꯫
ꯃꯃꯤ 6.1 — ꯀꯔꯕ ꯂꯩꯕ ꯂꯝꯕꯤ ꯑꯃꯗ ꯃꯥꯏꯅꯔ ꯑꯃꯁꯨꯡ ꯃꯦꯖꯔ ꯏꯔꯝ꯫ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ ꯑꯅꯧꯅꯥ ꯁꯦꯝꯕ ꯗ꯭ꯔꯣꯏꯡ, Kansas City Metro APWA, Section 5600 (2006, 5601.8) ꯑꯃꯁꯨꯡ FHWA, HEC-22 Urban Drainage Design Manual (4th ed., 2024)-ꯗꯒꯤ ꯍꯣꯡꯗꯣꯛꯂꯒꯥ ꯂꯧꯈꯤꯕ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. Ku = 0.376 ꯂꯩꯕ ꯃꯦꯅꯤꯡꯒꯤ ꯏꯀ꯭ꯋꯦꯁꯟꯒꯤ Izzard-ꯒꯤ ꯃꯑꯣꯡ ꯑꯁꯤ FHWA HEC-22 ꯑꯃꯁꯨꯡ CPHEEO (2019)-ꯒꯤ ꯃꯦꯅꯨꯌꯦꯜ (Part A, Example 5.5, ꯃꯐꯝ ꯑꯗꯨꯗ ꯀꯟꯁ꯭ꯇꯦꯟꯠ ꯑꯁꯤ Kc = 0.376 ꯍꯥꯌꯅꯥ ꯏꯔꯤ) ꯑꯅꯤꯃꯛꯇ ꯁꯤꯖꯤꯟꯅꯩ꯫ ꯑꯥꯔꯇꯤꯔꯤꯌꯦꯜꯒꯤ ꯁ꯭ꯞꯔꯦꯗꯀꯤ ꯔꯨꯜ (ꯂꯦꯟ ꯑꯃꯥ ꯌꯥꯝꯗꯕ) ꯑꯃꯁꯨꯡ ꯂꯣꯀꯦꯜ ꯑꯃꯁꯨꯡ ꯀꯂꯦꯛꯇꯔ ꯂꯝꯕꯤꯁꯤꯡꯒꯤ 3 m-ꯒꯤ ꯁ꯭ꯞꯔꯦꯗ ꯑꯁꯤ ꯃꯄꯥꯟꯊꯣꯡꯒꯤ ꯂꯦꯟ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯀꯔꯕꯀꯤ ꯃꯇꯨꯡꯗꯒꯤ 12 ft (3.66 m)-ꯒꯤ APWA 5600 (2006, 5604.2)-ꯒꯤ ꯂꯤꯃꯤꯠꯀꯥ ꯅꯛꯅꯩ꯫ 0.03 m³/s-ꯒꯤ ꯀ꯭ꯔꯣꯁ-ꯐ꯭ꯂꯣꯒꯤ ꯂꯤꯃꯤꯠ ꯑꯁꯤ ꯏꯟꯇꯔꯁꯦꯛꯁꯟ ꯁꯝꯞꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁꯨꯄꯔꯏꯂꯦꯚꯦꯁꯟ ꯇ꯭ꯔꯥꯟꯖꯤꯁꯟꯁꯤꯡꯗ 1.0 cfs-ꯒꯤ APWA-ꯒꯤ ꯂꯤꯃꯤꯠꯀꯤ SI-ꯒꯤ ꯃꯥꯟꯅꯕꯅꯤ, ꯃꯤꯗ-ꯕ꯭ꯂꯣꯛ ꯁꯝꯞꯁꯤꯡꯗ ꯀ꯭ꯔꯣꯁ-ꯐ꯭ꯂꯣ ꯂꯩꯇꯅꯥ꯫ 150 mm ꯑꯃꯁꯨꯡ 350 mm-ꯒꯤ ꯑꯏꯡꯕꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ ꯑꯁꯤ ꯂꯝꯕꯤ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡꯗ 1% ꯑꯣꯚꯔꯐ꯭ꯂꯣꯒꯤ APWA 5600-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯒꯥ ꯅꯛꯅꯩ (ꯀ꯭ꯔꯥꯎꯟꯗ 7 in, 180 mm ꯃꯔꯣꯜ; ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯑꯏꯡꯕ ꯃꯐꯝꯗ 14 in, 360 mm ꯃꯔꯣꯜ)꯫ 15 cm-ꯗꯒꯤ ꯍꯦꯟꯕ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯂꯩꯔꯣꯏꯗꯕꯒꯤ ꯃꯨꯝꯕꯥꯏꯒꯤ ꯀ꯭ꯔꯥꯏꯇꯦꯔꯤꯌꯟ (IRC:SP:50-2013, §6.4.1) ꯑꯁꯤ 150 mm-ꯒꯤ ꯀ꯭ꯔꯥꯎꯟ ꯚꯦꯜꯌꯨꯒꯤꯗꯃꯛ ꯂꯣꯀꯦꯜ ꯈꯨꯗꯝ ꯑꯃꯅꯤ꯫
ꯇꯦꯕꯜ 6.4-ꯒꯤ ꯍꯖꯥꯔꯗ ꯀ꯭ꯂꯥꯁꯁꯤꯡ ꯑꯁꯤ Australian Institute for Disaster Resilience-ꯅꯥ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯀꯝꯕꯥꯏꯟꯗ ꯍꯖꯥꯔꯗ ꯀꯔꯚꯁꯤꯡꯅꯤ (AIDR Guideline 7-3, 2014), ꯃꯈꯣꯌ ꯑꯁꯤ Smith and Wasko (2012)-ꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ ꯃꯣꯗꯦꯜ ꯇꯧꯔꯕꯅꯤ꯫ ꯀꯦꯔꯤꯌꯦꯖꯋꯦꯁꯤꯡꯗ H2 ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯐꯕ ꯃꯊꯧ ꯇꯥꯕ ꯑꯁꯤꯒꯤ ꯑꯔꯊꯗꯤ 350 mm-ꯒꯤ 1%-ꯒꯤ ꯑꯏꯡꯕꯒꯤ ꯂꯤꯃꯤꯠ (ꯇꯦꯕꯜ 6.2) ꯑꯁꯤꯅꯥ ꯑꯏꯡꯕ ꯑꯗꯨ ꯂꯩꯉꯥꯀꯏ, ꯑꯃꯁꯨꯡ D·V ꯄ꯭ꯔꯣꯗꯛꯠꯅꯥ ꯑꯉꯃꯕ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯊꯨꯅꯥ ꯆꯦꯟꯕ, ꯑꯏꯡꯕ ꯍꯟꯊꯕ ꯐ꯭ꯂꯣ ꯀꯟꯇ꯭ꯔꯣꯜ ꯇꯧꯏ꯫ H2 ꯑꯁꯤ "ꯑꯄꯤꯛꯄ ꯒꯥꯔꯤꯁꯤꯡꯒꯤꯗꯃꯛ ꯑꯁꯣꯏꯕ ꯂꯩ" ("unsafe for small vehicles") ꯍꯥꯌꯅꯥ ꯁꯟꯗꯣꯀꯏ꯫ ꯃꯅꯤꯄꯨꯔꯒꯤ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯌꯥꯝꯅꯥ ꯆꯠꯂꯤꯕ ꯒꯥꯔꯤꯁꯤꯡꯗꯤ ꯇꯨ-ꯍ꯭ꯕꯤꯂꯔꯁꯤꯡꯅꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ 1%-ꯒꯤ ꯏꯚꯦꯟꯠ ꯑꯁꯤ H1 ꯌꯧꯒꯗꯕ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯏꯚꯦꯀꯨꯌꯦꯁꯟ ꯔꯨꯠꯁꯤꯡ ꯅꯠꯇꯕꯗꯤ ꯂꯝꯕꯤ ꯄꯨꯝꯅꯃꯛꯇ ꯂꯝꯕꯤ ꯊꯤꯡꯕꯒꯤ ꯏꯚꯦꯟꯠ ꯑꯣꯏꯅꯥ ꯂꯧꯒꯗꯕꯅꯤ꯫ ꯇꯦꯕꯜ 6.3-ꯗ ꯃꯐꯝꯁꯤꯡꯗ ꯍꯖꯥꯔꯗ ꯀ꯭ꯂꯥꯁꯁꯤꯡ ꯄꯤꯕ ꯑꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯃꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫
6.6 ꯏꯟꯂꯦꯠꯁꯤꯡ
6.6.1 ꯏꯟꯂꯦꯠꯀꯤ ꯃꯈꯜꯁꯤꯡ. ꯏꯟꯂꯦꯠꯁꯤꯡ ꯑꯁꯤ ꯀꯔꯕ-ꯑꯣꯄꯅꯤꯡ ꯏꯟꯂꯦꯠꯁꯤꯡ, ꯒ꯭ꯔꯦꯠ ꯏꯟꯂꯦꯠꯁꯤꯡ, ꯀꯝꯕꯤꯅꯦꯁꯟ ꯏꯟꯂꯦꯠꯁꯤꯡ (ꯀꯔꯕ ꯑꯣꯄꯅꯤꯡ ꯂꯩꯕ ꯒ꯭ꯔꯦꯠ ꯑꯃꯥ) ꯅꯠꯔꯒꯥ ꯁ꯭ꯂꯣꯠ ꯇꯧꯔꯕ ꯑꯃꯁꯨꯡ ꯇ꯭ꯔꯦꯟꯆ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯣꯏꯕ ꯌꯥꯏ꯫ ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯕꯤꯁꯤꯡꯗ:
- (a) ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯑꯀꯛꯅꯕ ꯃꯐꯝ ꯑꯃꯒꯤꯗꯃꯛ ꯒ꯭ꯔꯦꯠ ꯈꯛꯇꯃꯛ ꯂꯩꯕ ꯏꯟꯂꯦꯠꯁꯤꯡ ꯌꯥꯗ꯭ꯔꯕꯗꯤ, ꯀꯔꯕ-ꯑꯣꯄꯅꯤꯡ ꯅꯠꯔꯒꯥ ꯀꯝꯕꯤꯅꯦꯁꯟ ꯏꯟꯂꯦꯠꯁꯤꯡ ꯁꯤꯖꯤꯟꯅꯒꯗꯕꯅꯤ;
- (b) ꯏꯟꯂꯦꯠꯀꯤ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡ ꯑꯁꯤ ꯂꯝꯕꯤꯒꯤ ꯂꯦꯚꯦꯜꯗ ꯊꯝꯒꯗꯕꯅꯤ, ꯇꯧꯕ ꯌꯥꯕ ꯃꯐꯝꯗ ꯒꯇꯔ ꯗꯤꯞꯔꯦꯁꯟ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯋꯥꯡꯈꯠꯂꯕ ꯀꯔꯕ ꯅꯠꯔꯒꯥ ꯐꯨꯠꯄꯥꯊ ꯑꯃꯅꯥ ꯀꯦꯔꯤꯌꯦꯖꯋꯦꯗ ꯏꯁꯤꯡ ꯊꯤꯡꯖꯤꯜꯂꯣꯏ;
- (c) ꯀꯦꯔꯤꯌꯦꯖꯋꯦꯁꯤꯡ, ꯁꯥꯏꯀꯜ ꯂꯦꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯐꯨꯠꯄꯥꯊꯁꯤꯡꯗ ꯂꯩꯕ ꯒ꯭ꯔꯦꯠꯁꯤꯡ ꯑꯁꯤ ꯁꯥꯏꯀꯜ ꯑꯃꯁꯨꯡ ꯈꯣꯡꯅꯥ ꯆꯠꯄꯁꯤꯡꯒꯤꯗꯃꯛ ꯑꯁꯣꯏꯕ ꯂꯩꯇꯕ ꯄꯦꯇꯔꯟ ꯑꯃꯒꯤ ꯑꯣꯏꯒꯗꯕꯅꯤ (ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.11)꯫
6.6.2 ꯏꯟꯂꯦꯠꯀꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ. ꯒ꯭ꯔꯦꯗꯇ ꯑꯃꯁꯨꯡ ꯁꯦꯒꯁꯤꯡꯗ ꯂꯩꯕ ꯏꯟꯂꯦꯠꯁꯤꯡꯒꯤ ꯁꯦꯡꯂꯕ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯁꯤ FHWA HEC-22 (4th edition, 2024)-ꯒꯤ ꯊꯧꯑꯣꯡꯁꯤꯡꯅꯥ, ꯅꯠꯔꯒꯥ ꯑꯆꯨꯝꯕ ꯒ꯭ꯔꯦꯠ ꯑꯃꯁꯨꯡ ꯀꯔꯕ-ꯑꯣꯄꯅꯤꯡꯒꯤ ꯖꯤꯑꯣꯃꯦꯇ꯭ꯔꯤꯒꯤꯗꯃꯛ ꯃꯦꯅꯨꯐꯦꯛꯆꯔꯔꯅꯥ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯇꯦꯁ꯭ꯠ ꯇꯧꯔꯕ ꯔꯦꯇꯤꯡꯁꯤꯡꯗꯒꯤ ꯊꯤꯒꯗꯕꯅꯤ꯫ CPHEEO (2019) Part A §5.6.2-ꯒꯤ ꯑꯦꯝꯄꯤꯔꯤꯀꯦꯜ ꯀꯔꯕ-ꯏꯟꯂꯦꯠ ꯏꯀ꯭ꯋꯦꯁꯟꯁꯤꯡ ꯑꯁꯤ ꯀ꯭ꯔꯣꯁ-ꯆꯦꯛ ꯑꯣꯏꯅꯥ ꯈꯛꯇꯃꯛ ꯁꯤꯖꯤꯟꯅꯕ ꯌꯥꯏ꯫
6.6.3 ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔꯁꯤꯡ. ꯏꯟꯂꯦꯠ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯗꯤꯖꯥꯏꯟ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯁꯤ ꯃꯁꯤꯒꯤ ꯁꯦꯡꯂꯕ ꯀꯦꯄꯥꯁꯤꯇꯤꯗꯒꯤ ꯇꯦꯕꯜ 6.5-ꯒꯤ ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔꯁꯤꯡꯅꯥ ꯍꯟꯊꯍꯜꯂꯕ ꯑꯗꯨ ꯑꯣꯏꯒꯗꯕꯅꯤ:
ꯇꯦꯕꯜ 6.5 — ꯏꯟꯂꯦꯠꯀꯤ ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔꯁꯤꯡ (ꯃꯥꯡꯏ ꯍꯥꯌꯅꯥ ꯂꯧꯕ ꯁꯦꯡꯂꯕ ꯀꯦꯄꯥꯁꯤꯇꯤꯒꯤ ꯁꯔꯨꯛ)
| ꯏꯟꯂꯦꯠꯀꯤ ꯃꯈꯜ | ꯒ꯭ꯔꯦꯗꯇ | ꯁꯦꯒ ꯑꯃꯗ |
|---|---|---|
| ꯒ꯭ꯔꯦꯠ | 50% | 50% |
| ꯀꯔꯕ ꯑꯣꯄꯅꯤꯡ | 10% | 20% |
| ꯀꯝꯕꯤꯅꯦꯁꯟ | ꯒ꯭ꯔꯦꯠ ꯑꯃꯁꯨꯡ ꯀꯔꯕꯀꯤ ꯐꯦꯛꯇꯔꯁꯤꯡ ꯁꯔꯨꯛ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯇꯣꯉꯥꯟꯅꯥ ꯁꯤꯖꯤꯟꯅꯒꯗꯕꯅꯤ | ꯒ꯭ꯔꯦꯠ ꯑꯃꯁꯨꯡ ꯀꯔꯕꯀꯤ ꯐꯦꯛꯇꯔꯁꯤꯡ ꯁꯔꯨꯛ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯇꯣꯉꯥꯟꯅꯥ ꯁꯤꯖꯤꯟꯅꯒꯗꯕꯅꯤ |
ꯗꯤꯖꯥꯏꯟ ꯀꯦꯄꯥꯁꯤꯇꯤ = (1 − ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔ) × ꯁꯦꯡꯂꯕ ꯀꯦꯄꯥꯁꯤꯇꯤ꯫
6.6.4 ꯏꯟꯂꯦꯠꯀꯤ ꯂꯥꯞ ꯊꯥꯛ. ꯏꯟꯂꯦꯠꯁꯤꯡ ꯑꯁꯤ ꯒꯇꯔ ꯔꯟ (gutter run) ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯊꯛꯇꯒꯤ ꯍꯧꯕ ꯃꯊꯡ ꯃꯊꯡꯒꯤ ꯀꯦꯜꯀꯨꯂꯦꯁꯟ ꯑꯃꯅꯥ ꯊꯝꯒꯗꯕꯅꯤ꯫ ꯏꯟꯂꯦꯠ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯊꯤꯡꯂꯕ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯊꯤꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯕꯥꯏꯄꯥꯁ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯃꯊꯡꯒꯤ ꯏꯟꯂꯦꯠꯇ ꯌꯧꯔꯀꯄ ꯒꯇꯔꯒꯤ ꯐ꯭ꯂꯣꯗ ꯍꯥꯄꯆꯤꯟꯒꯗꯕꯅꯤ꯫ ꯂꯥꯞ ꯊꯥꯛ ꯑꯁꯤ ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯏꯚꯦꯟꯠꯇ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯇꯦꯕꯜ 6.2-ꯒꯤ ꯁ꯭ꯞꯔꯦꯗꯀꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ ꯌꯧꯕ ꯑꯣꯏꯒꯗꯕꯅꯤ꯫ ꯃꯁꯤꯒꯤ ꯃꯊꯛꯇ:
- (a) ꯀꯦꯜꯀꯨꯂꯦꯁꯟꯅꯥ ꯀꯔꯤ ꯄꯤꯔꯕꯁꯨ, ꯀꯔꯕ ꯂꯩꯕ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯏꯟꯂꯦꯠꯀꯤ ꯂꯥꯞ ꯊꯥꯛ ꯑꯁꯤ 30 m-ꯗꯒꯤ ꯍꯦꯟꯂꯣꯏꯗꯕꯅꯤ;
- (b) ꯏꯟꯂꯦꯠꯁꯤꯡ ꯑꯁꯤ ꯁꯦꯒ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯄꯦꯗꯦꯁ꯭ꯇ꯭ꯔꯤꯌꯟ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯏꯟꯇꯔꯁꯦꯛꯁꯟꯁꯤꯡꯒꯤ ꯃꯊꯛ ꯊꯡꯕ ꯃꯐꯝꯗ ꯃꯈꯨꯠꯇꯥ, ꯕ꯭ꯔꯤꯖ ꯗꯦꯛꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁꯨꯄꯔꯏꯂꯦꯚꯦꯁꯟ ꯇ꯭ꯔꯥꯟꯖꯤꯁꯟꯁꯤꯡꯒꯤ ꯃꯊꯛ ꯊꯡꯕ ꯃꯐꯝꯗ, ꯑꯃꯁꯨꯡ ꯒꯇꯔ ꯔꯟ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯑꯔꯣꯏꯕꯗ ꯊꯝꯒꯗꯕꯅꯤ;
- (c) ꯔꯟ ꯑꯃꯒꯤ ꯑꯔꯣꯏꯕ ꯏꯟꯂꯦꯠꯇꯒꯤ ꯊꯣꯀꯄ ꯕꯥꯏꯄꯥꯁ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕ ꯀ꯭ꯂꯥꯁꯀꯤ ꯂꯝꯕꯤ ꯑꯃꯗ ꯅꯠꯔꯒꯥ ꯄ꯭ꯔꯥꯏꯚꯦꯠ ꯂꯝꯗ ꯊꯥꯔꯣꯏꯗꯕꯅꯤ꯫
6.6.5 ꯁꯦꯒꯀꯤ ꯏꯟꯂꯦꯠꯁꯤꯡ. ꯀꯔꯕ ꯂꯩꯕ ꯂꯝꯕꯤ ꯑꯃꯒꯤ ꯁꯦꯒ ꯑꯃꯗ:
- (a) ꯁꯦꯒ ꯏꯟꯂꯦꯠꯀꯤ ꯗꯤꯖꯥꯏꯟ ꯀꯦꯄꯥꯁꯤꯇꯤ (ꯀꯨꯞꯄ ꯂꯧꯔꯕ ꯃꯇꯨꯡꯗ) ꯑꯁꯤ ꯁꯦꯒ ꯑꯗꯨꯗ ꯌꯧꯔꯀꯄ ꯃꯄꯨꯡ ꯐꯥꯕ ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯗꯒꯤ ꯍꯟꯊꯔꯣꯏꯗꯕꯅꯤ;
- (b) ꯏꯁꯤꯡ ꯂꯦꯞꯄ ꯑꯁꯤ ꯇꯦꯕꯜ 6.2-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯁꯟꯗꯣꯛꯄ ꯌꯥꯕ ꯂꯝꯕꯤ ꯑꯃꯍꯦꯛꯇꯒꯤ ꯁꯦꯒ ꯑꯃꯒꯤ ꯃꯥꯏꯀꯩ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯑꯃꯁꯨꯡ ꯑꯟꯗꯔꯄꯥꯁ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯐ꯭ꯂꯦꯉ꯭ꯀꯤꯡ ꯏꯟꯂꯦꯠꯁꯤꯡ (flanking inlet) ꯊꯝꯒꯗꯕꯅꯤ;
- (c) ꯁꯦꯒ ꯑꯗꯨꯗ ꯏꯁꯤꯡ ꯂꯦꯞꯄ ꯑꯁꯤꯅꯥ ꯀ꯭ꯂꯣꯖ 6.10 ꯌꯧꯒꯗꯕꯅꯤ꯫
6.6.6 ꯏꯟꯂꯦꯠꯀꯤ ꯀꯅꯦꯛꯁꯟꯁꯤꯡ. ꯏꯟꯂꯦꯠ ꯑꯃꯕꯨ ꯃꯔꯨꯑꯣꯏꯕ ꯈꯣꯡꯕꯥꯟꯗ ꯁꯝꯃꯤꯟꯅꯍꯟꯕ ꯄꯥꯏꯞ ꯑꯁꯤꯒꯤ ꯗꯥꯏꯃꯤꯇꯔ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 300 mm ꯂꯩꯒꯗꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯏꯟꯂꯦꯠꯀꯤ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯗ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 0.9 m/s ꯄꯤꯕ ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠ ꯑꯃꯗ ꯊꯝꯒꯗꯕꯅꯤ꯫
6.6.7 ꯂꯩꯃꯨꯒꯤ ꯁꯝꯞꯁꯤꯡ (silt sump). ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯕꯤ ꯑꯃꯗ ꯂꯩꯕ ꯏꯟꯂꯦꯠ ꯆꯦꯝꯕꯔ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯃꯁꯤꯒꯤ ꯑꯥꯎꯠꯂꯦꯠ ꯄꯥꯏꯞꯀꯤ ꯏꯟꯚꯔꯠꯀꯤ ꯃꯈꯥꯗ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 300 mm ꯑꯏꯡꯕ, ꯃꯊꯛꯇꯒꯤ ꯁꯦꯡꯗꯣꯛꯅꯕ ꯆꯡꯕ ꯌꯥꯕ ꯂꯩꯃꯨꯒꯤ ꯁꯝꯞ ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ꯫
ꯃꯃꯤ 6.2 — ꯒꯇꯔꯒꯤ ꯁ꯭ꯞꯔꯦꯗ, ꯏꯟꯂꯦꯠꯅꯥ ꯊꯤꯡꯕ ꯑꯃꯁꯨꯡ ꯀꯨꯞꯄ꯫ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ ꯑꯅꯧꯅꯥ ꯁꯦꯝꯕ ꯗ꯭ꯔꯣꯏꯡ, FHWA, HEC-22 Urban Drainage Design Manual (3rd ed., 2009; 4th ed., 2024) ꯑꯃꯁꯨꯡ CPHEEO, Manual on Storm Water Drainage Systems (2019)-ꯗꯒꯤ ꯍꯣꯡꯗꯣꯛꯂꯒꯥ ꯂꯧꯈꯤꯕ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔꯁꯤꯡ ꯑꯁꯤ ꯁꯝꯞ ꯏꯟꯂꯦꯠꯁꯤꯡ ꯊꯤꯑꯣꯔꯦꯇꯤꯀꯦꯜ ꯀꯦꯄꯥꯁꯤꯇꯤꯒꯤ 80%-ꯗ (20% ꯍꯟꯊꯍꯟꯕ) ꯔꯦꯇꯤꯡ ꯇꯧꯕ APWA 5600 (2006, 5604.2)-ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯀꯟꯏ, ꯃꯔꯝꯗꯤ ꯃꯅꯤꯄꯨꯔꯒꯤ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯂꯩꯕ ꯒ꯭ꯔꯦꯠꯁꯤꯡ ꯑꯁꯤ ꯃꯇꯝ ꯄꯨꯝꯕꯗ ꯄ꯭ꯂꯥꯁ꯭ꯇꯤꯛ ꯑꯃꯁꯨꯡ ꯎꯃꯅꯥꯁꯤꯡꯅꯥ ꯊꯤꯡꯏ꯫ CPHEEO (2019) Part A-ꯅꯥ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯊꯥꯗꯣꯀꯄ ꯁꯣꯂꯤꯗ ꯋꯦꯁ꯭ꯠ ꯑꯁꯤ ꯈꯣꯡꯕꯥꯟ ꯐꯦꯜ ꯇꯧꯕꯒꯤ ꯃꯔꯨꯑꯣꯏꯕ ꯃꯔꯝ ꯑꯃꯥ ꯑꯣꯏꯅꯥ ꯎꯠꯂꯤ (Figures 1.2 and 2.1)꯫ APWA 5600 (2006)-ꯅꯥ ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯀꯔꯕ-ꯑꯣꯄꯅꯤꯡ ꯏꯟꯂꯦꯠꯁꯤꯡ ꯈꯛꯇꯃꯛ ꯌꯥꯍꯜꯂꯤ; ꯀ꯭ꯂꯣꯖ 6.6.1(a) ꯑꯁꯤ ꯍꯦꯟꯅꯥ ꯀꯟꯗꯦ, ꯃꯔꯝꯗꯤ ꯐꯥꯔꯕ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯀꯝꯕꯤꯅꯦꯁꯟ ꯏꯟꯂꯦꯠꯁꯤꯡ ꯀꯥꯟꯅꯩ꯫ ꯔꯤꯁꯔꯆꯀꯤ ꯃꯇꯝꯗ PWD-ꯒꯤ, IMC-ꯒꯤ ꯅꯠꯔꯒꯥ ꯁ꯭ꯇꯦꯠꯀꯤ ꯑꯇꯣꯞꯄ ꯂꯣꯀꯜ ꯕꯣꯗꯤ ꯑꯃꯠꯇꯒꯤ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯏꯟꯂꯦꯠ, ꯀꯔꯕ-ꯆꯦꯅꯦꯜ ꯅꯠꯔꯒꯥ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯗꯤꯇꯦꯜ ꯑꯃꯠꯇꯥ ꯐꯡꯈꯤꯗꯦ [TBC]꯫ AIIB ꯄ꯭ꯔꯣꯖꯦꯛꯠꯀꯤ ꯃꯍꯧꯁꯥꯒꯤ ꯁꯦꯛꯁꯟꯁꯤꯡꯅꯥ ꯒ꯭ꯔꯦꯇꯤꯡ ꯂꯩꯕ PCC ꯈꯣꯡꯕꯥꯟꯁꯤꯡ, "@25 m ꯂꯥꯞ ꯊꯥꯛ" ("@25 m interval") ꯂꯩꯕ ꯑꯥꯎꯠꯂꯦꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ "ꯄꯣꯔ ꯋꯥꯇꯔ ꯄ꯭ꯔꯦꯁꯔ ꯊꯥꯗꯣꯛꯅꯕ" ("release pore water pressure") 5 m ꯈꯨꯗꯤꯡꯗ 50-mm PVC ꯋꯤꯞ ꯄꯥꯏꯞꯁꯤꯡ ꯎꯠꯂꯤ, ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯗꯤꯖꯥꯏꯟ ꯑꯃꯠꯇꯥ ꯌꯥꯎꯗꯅꯥ (AIIB IEE); ꯑꯃꯁꯨꯡ ꯃꯣꯗꯦꯜ ꯕꯥꯏ-ꯂꯣꯖꯅꯥ "ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯜ/ꯑꯇꯣꯞꯄ ꯑꯣꯊꯣꯔꯤꯇꯤꯒꯤ ꯂꯩꯔꯤꯕ ꯄꯔꯃꯥꯅꯦꯟꯠ/ꯄꯛꯀꯥ ꯈꯣꯡꯕꯥꯟ ꯐꯥꯎꯕ ꯁꯥꯒꯠꯀꯗꯕ ꯃꯅꯨꯡ ꯑꯃꯁꯨꯡ ꯃꯄꯥꯟ ꯑꯅꯤꯃꯛꯀꯤ ꯑꯀꯨꯞꯄ ꯏꯔꯝꯒꯤ ꯄ꯭ꯂꯥꯟ" ("Detailed drainage plan for both internal and external required to be constructed up to the available permanent/pucca drain of municipal/other authority") ꯈꯛꯇꯃꯛ ꯍꯥꯏꯔꯤ (ꯕꯥꯏ-ꯂꯣ 6(1)(D) [TBC: ꯂꯣꯀꯜ ꯕꯣꯗꯤꯅꯥ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯕꯥꯏ-ꯂꯣꯖꯇ ꯅꯝꯕꯔ ꯑꯃꯁꯨꯡ ꯇꯦꯛꯁꯇ ꯆꯦꯛ ꯇꯧꯒꯗꯕꯅꯤ])꯫ 30 m-ꯒꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯍꯦꯟꯕ ꯂꯥꯞ ꯊꯥꯛ ꯑꯃꯁꯨꯡ ꯇꯦꯕꯜ 6.5-ꯗ ꯀꯝꯕꯤꯅꯦꯁꯟ ꯏꯟꯂꯦꯠꯁꯤꯡ ꯂꯧꯕ ꯃꯑꯣꯡ ꯑꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ "ꯈꯥ ꯊꯡꯕ ꯃꯥꯏꯀꯩꯗ ꯌꯥꯝꯅꯥ ꯍꯟꯊꯕ ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠ" ("a very low southerly gradient") ꯂꯩꯕ ꯏꯝꯐꯥꯜ ꯇꯝꯄꯥꯛꯀꯤ ꯂꯝꯗ ꯂꯩꯕ ꯂꯝꯕꯤꯁꯤꯡ (MASTEC) ꯑꯁꯤ ꯌꯥꯝꯅꯥ ꯐꯥꯔꯦ, ꯃꯁꯤꯅꯥ ꯀꯔꯤꯒꯨꯝꯕꯅꯥ ꯊꯤꯔꯕ ꯂꯥꯞ ꯊꯥꯛ ꯑꯗꯨ ꯅꯛꯍꯜꯂꯤ; ꯆꯤꯡꯒꯤ ꯁꯍꯔꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇꯝꯄꯥꯛꯀꯤ ꯃꯅꯥꯛꯀꯤ ꯑꯉꯃꯕ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯒꯇꯔꯒꯤ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯊꯨꯅꯥ ꯆꯦꯟꯏ ꯑꯃꯁꯨꯡ ꯏꯟꯂꯦꯠꯁꯤꯡꯒꯤ ꯃꯅꯥꯛꯇꯒꯤ ꯆꯦꯟꯊꯣꯀꯏ, ꯃꯁꯤꯒꯤ ꯃꯇꯥꯡꯗ ꯀ꯭ꯂꯣꯖ 6.3.6(j)-ꯅꯥ ꯌꯦꯡꯁꯤꯜꯂꯤ꯫ ꯐꯤꯛꯁ ꯇꯧꯔꯕ ꯀꯦꯞ ꯑꯃꯅꯥ ꯊꯤꯡꯂꯕ ꯏꯟꯂꯦꯠ ꯑꯃꯈꯛꯇꯅꯥ ꯁꯥꯡꯕ ꯒꯇꯔ ꯔꯟ ꯑꯃꯥ ꯏꯁꯤꯡ ꯂꯩꯇꯅꯥ ꯊꯝꯗꯅꯕ ꯊꯤꯡꯏ꯫ 300 mm-ꯒꯤ ꯂꯩꯃꯨꯒꯤ ꯁꯝꯞ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ ꯃꯁꯤ CPHEEO-ꯒꯤ ꯀꯦꯆ-ꯕꯦꯁꯤꯟ ꯗꯤꯇꯦꯜꯗ ꯎꯠꯂꯤꯕ 0.3 m-ꯒꯤ ꯁꯝꯞꯒꯥ ꯃꯥꯟꯅꯩ (CPHEEO 2019, Figure 5.9)꯫
6.7 ꯄꯥꯏꯞꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯑꯃꯁꯨꯡ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ
6.7.1 ꯌꯨꯅꯤꯐꯣꯔꯝ ꯐ꯭ꯂꯣ. ꯄꯥꯏꯞ ꯑꯃꯁꯨꯡ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯁꯤ ꯃꯦꯅꯤꯡꯒꯤ ꯏꯀ꯭ꯋꯦꯁꯟꯅꯥ ꯊꯤꯒꯗꯕꯅꯤ:
V = (1/n) · R^(2/3) · S^(1/2); Q = A · V
ꯃꯐꯝ ꯑꯁꯤꯗ V ꯑꯁꯤ ꯃꯤꯟ ꯚꯦꯂꯣꯁꯤꯇꯤ (m/s), n ꯑꯁꯤ ꯃꯦꯅꯤꯡ ꯔꯐꯅꯦꯁ (ꯇꯦꯕꯜ 6.6), R ꯑꯁꯤ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯔꯦꯗꯤꯌꯁ (m), S ꯑꯁꯤ ꯐ꯭ꯔꯤꯛꯁꯟ ꯁ꯭ꯂꯣꯞ (m/m), A ꯑꯁꯤ ꯐ꯭ꯂꯣ ꯑꯦꯔꯤꯌꯥ (m²) ꯑꯃꯁꯨꯡ Q ꯑꯁꯤ ꯗꯤꯁꯆꯥꯔꯖ (m³/s)꯫ ꯇꯦꯜꯋꯥꯇꯔ, ꯖꯉ꯭ꯀꯁꯟ ꯅꯠꯔꯒꯥ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔ ꯑꯃꯗꯒꯤ ꯂꯥꯀꯄ ꯕꯦꯛꯋꯥꯇꯔꯅꯥ (backwater) ꯏꯁꯤꯡꯒꯤ ꯂꯦꯚꯦꯜꯗ ꯑꯍꯣꯡꯕ ꯄꯨꯔꯀꯄ ꯃꯐꯝꯗ, ꯒ꯭ꯔꯦꯖꯨꯌꯦꯂꯤ ꯚꯦꯔꯤꯗ ꯐ꯭ꯂꯣ (gradually varied flow) (ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯁ꯭ꯇꯦꯞ) ꯅꯠꯔꯒꯥ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯅꯦꯠꯋꯔꯛ ꯃꯣꯗꯦꯜ ꯑꯃꯥ ꯁꯤꯖꯤꯟꯅꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 6.8-ꯒꯤ HGL-ꯒꯤ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡ ꯆꯠꯅꯩ꯫
6.7.2 ꯃꯦꯅꯤꯡ ꯔꯐꯅꯦꯁ. n-ꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯚꯦꯜꯌꯨꯁꯤꯡ ꯑꯁꯤ ꯇꯦꯕꯜ 6.6-ꯗꯒꯤ ꯂꯧꯒꯗꯕꯅꯤ꯫ ꯀꯟꯀ꯭ꯔꯤꯠ ꯄꯥꯏꯞꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯃꯦꯁꯟꯔꯤ ꯅꯠꯔꯒꯥ ꯀꯟꯀ꯭ꯔꯤꯠ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤꯗꯃꯛ, ꯗꯤꯖꯥꯏꯟ ꯚꯦꯜꯌꯨ ꯑꯁꯤ ꯁꯦꯗꯤꯃꯦꯟꯠ, ꯕꯥꯏꯑꯣꯐꯤꯜꯝ ꯑꯃꯁꯨꯡ ꯑꯔꯤꯕ ꯑꯣꯏꯕꯒꯤꯗꯃꯛ, ꯂꯤꯁ꯭ꯠ ꯇꯧꯔꯕ "ꯐꯦꯌꯔ" ("fair") ꯅꯠꯔꯒꯥ "ꯔꯐ" ("rough") ꯐꯤꯚꯝꯒꯤ ꯚꯦꯜꯌꯨꯗꯒꯤ ꯍꯟꯊꯔꯣꯏꯗꯕꯅꯤ꯫
ꯇꯦꯕꯜ 6.6 — ꯗꯤꯖꯥꯏꯟꯒꯤꯗꯃꯛ ꯃꯦꯅꯤꯡꯒꯤ n (CPHEEO 2019-ꯗꯒꯤ)
| ꯃꯦꯇꯦꯔꯤꯌꯦꯜ | ꯐꯤꯚꯝ | n (CPHEEO) | ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯗ ꯃꯤꯅꯤꯃꯝ ꯗꯤꯖꯥꯏꯟ n |
|---|---|---|---|
| ꯁꯤꯃꯦꯟꯠ ꯀꯟꯀ꯭ꯔꯤꯠ ꯄꯥꯏꯞ (ꯀꯣꯂꯥꯔ ꯖꯣꯏꯟꯠꯁꯤꯡ) | ꯐꯕ / ꯐꯦꯌꯔ | 0.013 / 0.015 | 0.015 |
| S/S ꯖꯣꯏꯟꯠ ꯂꯩꯕ ꯁ꯭ꯄꯟ ꯀꯟꯀ꯭ꯔꯤꯠ ꯄꯥꯏꯞ (RCC, PSC) | ꯃꯦꯅꯨꯐꯦꯛꯆꯔꯔꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯚꯦꯜꯌꯨ | 0.011 | 0.013 |
| HDPE / uPVC ꯄꯥꯏꯞ | — | 0.010 | 0.011 |
| ꯄ꯭ꯂꯥꯁ꯭ꯇꯤꯛ (ꯃꯅꯥꯛ ꯆꯦꯟꯕ), ꯑꯦꯁꯕꯦꯁ꯭ꯇꯣꯁ ꯁꯤꯃꯦꯟꯠ | — | 0.011 | 0.011 |
| ꯀꯟꯀ꯭ꯔꯤꯠ ꯈꯣꯡꯕꯥꯟ, ꯁ꯭ꯇꯤꯜ ꯇ꯭ꯔꯣꯋꯦꯜ ꯇꯧꯔꯕ / ꯎꯒꯤ ꯇ꯭ꯔꯣꯋꯦꯜ ꯇꯧꯔꯕ | — | 0.014 / 0.015 | 0.015 |
| ꯂꯩꯉꯣꯏ ꯑꯃꯁꯨꯡ ꯁꯤꯃꯦꯟꯠ ꯄ꯭ꯂꯥꯁ꯭ꯇꯔ | — | 0.015 | 0.015 |
| ꯆꯦꯛ ꯃꯦꯁꯟꯔꯤ | ꯐꯕ / ꯔꯐ | 0.015 / 0.017 | 0.017 |
| ꯃꯦꯁꯟꯔꯤ | ꯐꯠꯇꯕ ꯐꯤꯚꯝ | 0.020 | 0.020 |
| ꯁꯤꯃꯦꯟꯠꯇ ꯊꯝꯂꯕ ꯔꯕꯜ | — | 0.017 | 0.017 |
| ꯂꯩꯃꯥꯏꯒꯤ ꯆꯦꯅꯦꯜ | ꯔꯦꯒꯨꯂꯔ, ꯐꯕ / ꯑꯣꯔꯗꯤꯅꯔꯤ | 0.020 / 0.025 | 0.025 |
| ꯂꯩꯃꯥꯏꯒꯤ ꯆꯦꯅꯦꯜ | ꯅꯨꯡꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯅꯥꯎꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ / ꯐꯠꯇꯕ | 0.030 / 0.035 | 0.035 |
| ꯂꯩꯃꯥꯏꯒꯤ ꯆꯦꯅꯦꯜ | ꯗꯦꯕ꯭ꯔꯤꯁ ꯅꯠꯔꯒꯥ ꯅꯥꯎꯁꯤꯡꯅꯥ ꯁꯔꯨꯛ ꯈꯔ ꯊꯤꯡꯂꯕ | 0.050 | 0.050 |
| ꯒꯇꯔ: ꯀꯟꯀ꯭ꯔꯤꯠ | — | 0.013 | 0.013 |
| ꯒꯇꯔ: ꯍꯣꯠ-ꯃꯤꯛꯁ ꯑꯦꯁꯐꯥꯜꯠ | — | 0.015 | 0.015 |
| ꯒꯇꯔ: ꯁ꯭ꯞꯔꯦ ꯇꯧꯔꯕ ꯁꯤꯜ | — | 0.018 | 0.018 |
CPHEEO ꯀꯂꯝꯒꯤ ꯍꯧꯔꯛꯐꯝ: CPHEEO (2019) Part A, Table 5.1 (ꯃꯁꯥꯃꯛ CPHEEO Manual on Sewerage and Sewage Treatment Systems, 2013-ꯗꯒꯤ) ꯑꯃꯁꯨꯡ Table 5.8 (ꯒꯇꯔꯁꯤꯡ)꯫
6.7.3 ꯚꯦꯂꯣꯁꯤꯇꯤꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ. ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯗ:
- (a) ꯃꯤꯅꯤꯃꯝ (ꯃꯁꯥꯅꯥ ꯁꯦꯡꯗꯣꯀꯄ) ꯚꯦꯂꯣꯁꯤꯇꯤ: ꯍꯥꯡꯗꯣꯛꯂꯕ ꯑꯃꯁꯨꯡ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ 0.6 m/s ꯑꯃꯁꯨꯡ ꯄꯥꯏꯞꯁꯤꯡꯗ 0.9 m/s;
- (b) ꯃꯦꯛꯁꯤꯃꯝ ꯚꯦꯂꯣꯁꯤꯇꯤ: ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯄꯥꯏꯞꯁꯤꯡꯗ 3.0 m/s, ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯄꯥꯏꯞ ꯑꯗꯨ ꯁꯔꯨꯛ 9-ꯒꯤ ꯃꯈꯥꯗ ꯁꯨꯠ ꯑꯃꯥ ꯑꯣꯏꯅꯥ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯗ꯭ꯔꯕꯗꯤ꯫ CPHEEO-ꯅꯥ ꯆꯤꯡꯒꯤ ꯂꯝꯁꯤꯡꯗ ꯄ꯭ꯂꯥꯁ꯭ꯇꯤꯛ ꯅꯠꯔꯒꯥ ꯄ꯭ꯂꯥꯁ꯭ꯇꯤꯛꯅꯥ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯄꯥꯏꯞꯁꯤꯡꯗ 6.0 m/s ꯐꯥꯎꯕ ꯌꯥꯍꯜꯂꯤ; ꯃꯁꯤ ꯏꯝꯐꯥꯜ ꯇꯝꯄꯥꯛꯀꯤ ꯆꯤꯡꯒꯤ ꯃꯄꯥꯟꯁꯤꯡ, ꯇꯃꯦꯡꯂꯣꯡ, ꯅꯣꯅꯦ, ꯎꯈ꯭ꯔꯨꯜ, ꯁꯦꯅꯥꯄꯇꯤ, ꯀꯥꯡꯄꯣꯛꯄꯤ, ꯆꯥꯟꯗꯦꯜ ꯑꯃꯁꯨꯡ ꯆꯨꯔꯆꯥꯟꯗꯄꯨꯔ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯆꯤꯡꯒꯤ ꯁꯍꯔꯁꯤꯡꯗ ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯒꯤ ꯌꯥꯅꯕꯒꯥ ꯂꯣꯌꯅꯅ ꯁꯤꯖꯤꯟꯅꯕ ꯌꯥꯏ;
- (c) ꯂꯥꯏꯟ ꯇꯧꯗꯕ ꯑꯃꯁꯨꯡ ꯄꯥꯝꯕꯤ ꯂꯩꯕ ꯆꯦꯅꯦꯜꯁꯤꯡꯗ ꯃꯦꯛꯁꯤꯃꯝ ꯚꯦꯂꯣꯁꯤꯇꯤ: ꯁꯔꯨꯛ 9, ꯇꯦꯕꯜ 9.2;
- (d) ꯍꯥꯡꯗꯣꯛꯂꯕ ꯑꯃꯁꯨꯡ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯂꯩꯕ ꯐ꯭ꯂꯣꯒꯤ ꯐ꯭ꯔꯨꯗ ꯅꯝꯕꯔ ꯑꯁꯤ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯗ 0.8-ꯗꯒꯤ ꯍꯦꯟꯂꯣꯏꯗꯕꯅꯤ, ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨ ꯁꯔꯨꯛ 9-ꯒꯤ ꯃꯈꯥꯗ ꯁꯨꯄꯔꯀ꯭ꯔꯤꯇꯤꯀꯦꯜ ꯐ꯭ꯂꯣ (supercritical flow)-ꯒꯤꯗꯃꯛ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯗ꯭ꯔꯕꯗꯤ꯫
6.7.4 ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠ. ꯄꯥꯏꯞ ꯑꯃꯁꯨꯡ ꯈꯣꯡꯕꯥꯟ ꯈꯨꯗꯤꯡꯃꯛ ꯀ꯭ꯂꯣꯖ 6.7.3(a) ꯌꯧꯍꯅꯕ ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠ ꯑꯃꯗ ꯊꯝꯒꯗꯕꯅꯤ꯫ ꯐꯥꯔꯕ ꯂꯩꯃꯥꯏ ꯅꯠꯔꯒꯥ ꯐꯤꯛꯁ ꯇꯧꯔꯕ ꯑꯥꯎꯠꯐꯣꯜ ꯂꯦꯚꯦꯜ ꯑꯃꯅꯥ ꯃꯁꯤ ꯇꯧꯕ ꯌꯥꯍꯟꯗꯕ ꯃꯐꯝꯗ, ꯗꯤꯖꯥꯏꯅꯔꯅꯥ:
- (a) ꯐꯡꯂꯕ ꯚꯦꯂꯣꯁꯤꯇꯤ ꯑꯗꯨ ꯔꯤꯄꯣꯔꯠ ꯇꯧꯒꯗꯕꯅꯤ;
- (b) ꯀ꯭ꯂꯣꯖ 6.7.8-ꯒꯤ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁ ꯑꯗꯨ ꯑꯅꯤ ꯊꯣꯛ ꯍꯦꯟꯒꯠꯍꯅꯒꯗꯕꯅꯤ; ꯑꯃꯁꯨꯡ
- (c) ꯀ꯭ꯂꯣꯖ 6.13.2-ꯒꯤ ꯂꯥꯞ ꯊꯥꯛꯇ ꯃꯦꯀꯥꯅꯤꯀꯦꯜ ꯗꯤꯁꯤꯜꯇꯤꯡꯒꯤꯗꯃꯛ ꯆꯡꯂꯛꯄꯒꯤ ꯂꯝꯕꯤ ꯄꯤꯒꯗꯕꯅꯤ꯫
6.7.5 ꯄꯥꯏꯞꯀꯤ ꯐ꯭ꯂꯣꯒꯤ ꯐꯤꯚꯝ. ꯄꯥꯏꯞꯁꯤꯡ ꯑꯁꯤ ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯅꯥ ꯄꯥꯏꯞ ꯃꯄꯨꯟꯕꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤꯗꯒꯤ ꯍꯦꯟꯗꯅꯕ ꯁꯥꯏꯖ ꯂꯦꯞꯀꯗꯕꯅꯤ꯫ ꯑꯀꯣꯌꯕ ꯄꯥꯏꯞ ꯑꯃꯅꯥ ꯃꯁꯤꯒꯤ ꯑꯏꯡꯕꯒꯤ 0.95 ꯃꯔꯣꯜꯗ ꯄꯨꯕ ꯍꯦꯟꯅꯥ ꯆꯥꯎꯕ ꯗꯤꯁꯆꯥꯔꯖ ꯑꯗꯨꯗ ꯊꯥꯖꯕ ꯊꯝꯔꯣꯏꯗꯕꯅꯤ꯫
6.7.6 ꯃꯤꯅꯤꯃꯝ ꯁꯥꯏꯖꯁꯤꯡ.
- (a) ꯄꯥꯏꯞꯁꯤꯡ: ꯃꯅꯨꯡꯒꯤ ꯗꯥꯏꯃꯤꯇꯔ 300 mm; ꯄꯕ꯭ꯂꯤꯛ ꯃꯦꯟꯁꯤꯡꯒꯤꯗꯃꯛ 450 mm꯫
- (b) ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ: ꯃꯈꯥꯒꯤ ꯄꯥꯛꯄ 0.3 m꯫
- (c) ꯀꯚꯔ ꯇꯧꯔꯕ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ (ꯀꯚꯔ ꯁ꯭ꯂꯦꯕꯁꯤꯡꯅꯥ ꯊꯤꯡꯂꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ): ꯃꯅꯨꯡꯒꯤ ꯁꯦꯡꯂꯕ ꯄꯥꯛꯄ 0.6 m ꯑꯃꯁꯨꯡ ꯃꯅꯨꯡꯒꯤ ꯁꯦꯡꯂꯕ ꯑꯏꯡꯕ 0.6 m꯫
6.7.7 ꯄꯥꯏꯞꯁꯤꯡꯒꯤ ꯀꯚꯔ. ꯄꯥꯏꯞꯁꯤꯡꯗ ꯂꯣꯏꯁꯤꯟꯂꯕ ꯂꯦꯚꯦꯜ ꯐꯥꯎꯕ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 0.6 m-ꯒꯤ ꯀꯚꯔ ꯂꯩꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯇ꯭ꯔꯦꯐꯤꯛ ꯂꯣꯗꯀꯤꯗꯃꯛ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔꯦꯜ ꯗꯤꯖꯥꯏꯟ ꯑꯃꯥ ꯄꯤꯗ꯭ꯔꯕꯗꯤ ꯀꯦꯔꯤꯌꯦꯖꯋꯦꯁꯤꯡꯒꯤ ꯃꯈꯥꯗ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 0.9 m꯫ ꯃꯇꯝꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ ꯋꯥꯡꯕ ꯋꯥꯇꯔ ꯇꯦꯕꯜ ꯑꯁꯤ ꯄꯥꯏꯞꯀꯤ ꯀ꯭ꯔꯥꯎꯟꯗꯒꯤ 1 m-ꯒꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯕ ꯃꯐꯝꯗ, ꯄꯥꯏꯞ ꯑꯗꯨ ꯑꯍꯥꯡꯕ ꯐꯤꯚꯝꯗ ꯐ꯭ꯂꯣꯇꯦꯁꯟꯒꯤꯗꯃꯛ (flotation) ꯆꯦꯛ ꯇꯧꯒꯗꯕꯅꯤ (CPHEEO 2019, Table 11.2) ꯑꯃꯁꯨꯡ ꯃꯊꯧ ꯇꯥꯕ ꯃꯐꯝꯗ ꯑꯦꯉ꯭ꯀꯔ ꯇꯧꯒꯗꯕꯅꯤ꯫
6.7.8 ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁ. ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ, ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ 600 mm ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯗꯥꯏꯃꯤꯇꯔꯒꯤ ꯄꯥꯏꯞꯁꯤꯡꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯁꯤ ꯏꯟꯚꯔꯠꯇ ꯃꯈꯥꯒꯤ ꯑꯏꯡꯕꯒꯤ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯂꯩꯅꯥ ꯊꯤꯒꯗꯕꯅꯤ:
- (a) ꯍꯥꯡꯗꯣꯛꯂꯕ ꯑꯃꯁꯨꯡ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ: 75 mm ꯑꯃꯁꯨꯡ ꯃꯅꯨꯡꯒꯤ ꯁꯦꯡꯂꯕ ꯑꯏꯡꯕꯒꯤ 10%, ꯃꯈꯣꯌꯒꯤ ꯃꯔꯛꯇ ꯍꯦꯟꯅꯥ ꯆꯥꯎꯕ ꯑꯗꯨ;
- (b) 600 mm ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯗꯥꯏꯃꯤꯇꯔꯒꯤ ꯄꯥꯏꯞꯁꯤꯡ: ꯃꯅꯨꯡꯒꯤ ꯗꯥꯏꯃꯤꯇꯔꯒꯤ 5%;
- (c) 600 mm-ꯗꯒꯤ ꯍꯟꯊꯕ ꯄꯥꯏꯞꯁꯤꯡ: ꯑꯦꯂꯥꯎꯑꯦꯟꯁ ꯑꯃꯠꯇꯥ ꯂꯩꯇꯦ, ꯑꯗꯨꯕꯨ ꯀ꯭ꯂꯣꯖ 6.7.3(a) ꯌꯧꯒꯗꯕꯅꯤ꯫
ꯍꯟꯊꯍꯜꯂꯕ ꯁꯦꯛꯁꯟꯒꯤ ꯃꯦꯅꯤꯡ n ꯑꯁꯤ ꯇꯦꯕꯜ 6.6-ꯗ ꯂꯩꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯃꯦꯇꯦꯔꯤꯌꯦꯜꯒꯤ ꯑꯗꯨ ꯑꯣꯏꯒꯗꯕꯅꯤ꯫
6.7.9 ꯍꯥꯡꯗꯣꯛꯂꯕ ꯑꯃꯁꯨꯡ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯐ꯭ꯔꯤꯕꯣꯔꯗ. ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯗ, ꯏꯁꯤꯡꯒꯤ ꯃꯊꯛ (ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁꯒꯥ ꯂꯣꯌꯅꯅ ꯊꯤꯔꯕ) ꯑꯁꯤ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯋꯣꯜꯒꯤ ꯃꯊꯛꯇꯒꯤ, ꯅꯠꯔꯒꯥ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯀꯚꯔ ꯁ꯭ꯂꯦꯕꯀꯤ ꯁꯣꯐꯤꯠꯇꯒꯤ (soffit), ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ ꯇꯦꯕꯜ 6.7-ꯒꯤ ꯐ꯭ꯔꯤꯕꯣꯔꯗ ꯐꯥꯎꯕ ꯃꯈꯥꯗ ꯂꯩꯒꯗꯕꯅꯤ꯫
ꯇꯦꯕꯜ 6.7 — ꯍꯥꯡꯗꯣꯛꯂꯕ ꯑꯃꯁꯨꯡ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯃꯤꯅꯤꯃꯝ ꯐ꯭ꯔꯤꯕꯣꯔꯗ
| ꯈꯣꯡꯕꯥꯟ | ꯃꯤꯅꯤꯃꯝ ꯐ꯭ꯔꯤꯕꯣꯔꯗ | ꯍꯧꯔꯛꯐꯝ |
|---|---|---|
| ꯃꯈꯥꯒꯤ ꯄꯥꯛꯄ 300 mm ꯐꯥꯎꯕ | 100 mm | CPHEEO 2019 Table 5.3 (IRC:SP:50-2013-ꯗꯒꯤ) |
| ꯃꯈꯥꯒꯤ ꯄꯥꯛꯄ 300–900 mm | 150 mm | CPHEEO 2019 Table 5.3 |
| ꯃꯈꯥꯒꯤ ꯄꯥꯛꯄ 900–1,500 mm | 300 mm | CPHEEO 2019 Table 5.3 |
| ꯍꯦꯟꯅꯥ ꯄꯥꯛꯄ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯏꯟꯖꯤꯅꯤꯌꯔ ꯇꯧꯔꯕ ꯆꯦꯅꯦꯜꯁꯤꯡ, Q < 3 m³/s | 450 mm | CPHEEO 2019 Table 5.12 (IS 7784 (Part 1): 1993-ꯗꯒꯤ) |
| Q 3-ꯗꯒꯤ < 30 m³/s | 600 mm | ꯃꯊꯛꯇ ꯂꯩꯕꯒꯨꯝ |
| Q 30-ꯗꯒꯤ < 300 m³/s | 900 mm | ꯃꯊꯛꯇ ꯂꯩꯕꯒꯨꯝ |
| Q 300-ꯗꯒꯤ < 3,000 m³/s | 1,200 mm | ꯃꯊꯛꯇ ꯂꯩꯕꯒꯨꯝ |
| Q ≥ 3,000 m³/s | 1,500 mm | ꯃꯊꯛꯇ ꯂꯩꯕꯒꯨꯝ |
| ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯍꯦꯛꯇ | 150 mm-ꯗꯒꯤ ꯍꯟꯊꯔꯣꯏꯗꯕ | IRC:SP:42-2014 |
| ꯑꯉꯃꯕ (ꯁꯨꯄꯔꯀ꯭ꯔꯤꯇꯤꯀꯦꯜ) ꯆꯦꯅꯦꯜꯁꯤꯡ | ꯐ꯭ꯂꯣꯒꯤ ꯑꯏꯡꯕꯒꯥ ꯃꯥꯟꯅꯕ | CPHEEO 2019 §5.3.2 |
ꯀꯣꯏꯕ ꯃꯐꯝꯁꯤꯡꯗ, ꯐ꯭ꯔꯤꯕꯣꯔꯗ ꯑꯁꯤ ꯀꯣꯏꯕꯒꯤ ꯃꯄꯥꯟꯊꯣꯡꯗ ꯂꯩꯕ ꯏꯁꯤꯡꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯊꯥꯖꯒꯗꯕꯅꯤ, ꯁꯨꯄꯔꯏꯂꯦꯚꯦꯁꯟ Δy = V²T / (2 g rc) ꯌꯥꯑꯣꯅꯥ, ꯃꯐꯝ ꯑꯁꯤꯗ T ꯑꯁꯤ ꯃꯊꯛꯀꯤ ꯄꯥꯛꯄ ꯑꯃꯁꯨꯡ rc ꯑꯁꯤ ꯁꯦꯟꯇꯔꯂꯥꯏꯟꯒꯤ ꯔꯦꯗꯤꯌꯁꯅꯤ (CPHEEO 2019, Eq. 5.29)꯫
6.7.10 ꯀꯣꯏꯕ ꯃꯐꯝꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯖꯉ꯭ꯀꯁꯟꯁꯤꯡ.
- (a) ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯀꯣꯏꯕ ꯃꯐꯝ ꯑꯃꯒꯤ ꯁꯦꯟꯇꯔꯂꯥꯏꯟ ꯔꯦꯗꯤꯌꯁ ꯑꯁꯤ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯄꯥꯛꯄꯒꯤ 3 ꯊꯣꯛ ꯑꯣꯏꯒꯗꯕꯅꯤ (CPHEEO 2019 §5.3.3)꯫ ꯏꯟꯖꯤꯅꯤꯌꯔ ꯇꯧꯔꯕ ꯆꯦꯅꯦꯜꯁꯤꯡꯗ ꯃꯁꯤ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ ꯃꯊꯛꯀꯤ ꯄꯥꯛꯄꯒꯤ 2 ꯊꯣꯛ ꯑꯃꯁꯨꯡ 30 m-ꯗꯒꯤ ꯍꯟꯊꯔꯣꯏꯗꯕ ꯑꯣꯏꯒꯗꯕꯅꯤ (CPHEEO 2019 Table 5.11)꯫
- (b) ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯁꯝꯅꯕ ꯃꯐꯝꯗ, ꯊꯣꯛꯂꯛꯂꯤꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯄꯥꯛꯄꯒꯤ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ ꯑꯅꯤ ꯊꯣꯛ ꯃꯅꯨꯡꯒꯤ ꯄꯥꯛꯄ ꯂꯩꯕ ꯖꯉ꯭ꯀꯁꯟ ꯁꯝꯞ ꯑꯃꯥ ꯊꯝꯒꯗꯕꯅꯤ꯫ ꯆꯡꯂꯛꯂꯤꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯊꯣꯛꯂꯛꯂꯤꯕ ꯐ꯭ꯂꯣꯗ ꯔꯥꯏꯠ ꯑꯦꯉ꯭ꯒꯂꯗꯒꯤ ꯍꯟꯊꯕ ꯑꯦꯉ꯭ꯒꯂꯗ ꯆꯡꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯊꯣꯛꯂꯛꯂꯤꯕ ꯏꯟꯚꯔꯠ ꯑꯁꯤ ꯁꯝꯞꯀꯤ ꯃꯈꯥꯗ ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯁꯝꯞꯇ ꯏꯁꯤꯡ ꯂꯦꯞꯂꯣꯏ (CPHEEO 2019 §5.3.4)꯫
6.7.11 ꯄꯥꯏꯞꯁꯤꯡꯗ ꯃꯦꯟꯍꯣꯜꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯦꯛꯁꯦꯁ ꯆꯦꯝꯕꯔꯁꯤꯡ. ꯖꯉ꯭ꯀꯁꯟ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯁꯥꯏꯖ, ꯑꯦꯂꯥꯏꯅꯃꯦꯟꯠ ꯅꯠꯔꯒꯥ ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠ ꯍꯣꯡꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯑꯃꯁꯨꯡ ꯄꯥꯏꯞ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯊꯛꯇ ꯃꯦꯟꯍꯣꯜꯁꯤꯡ ꯊꯝꯒꯗꯕꯅꯤ꯫ ꯆꯨꯃꯊꯣꯛꯂꯕ ꯔꯟꯁꯤꯡꯗ ꯂꯥꯞ ꯊꯥꯛ ꯑꯁꯤ ꯇꯦꯕꯜ 6.8-ꯗꯒꯤ ꯍꯦꯟꯂꯣꯏꯗꯕꯅꯤ꯫
ꯇꯦꯕꯜ 6.8 — ꯆꯨꯃꯊꯣꯛꯂꯕ ꯄꯥꯏꯞ ꯔꯟꯁꯤꯡꯗ ꯃꯦꯟꯍꯣꯜꯁꯤꯡꯒꯤ ꯃꯦꯛꯁꯤꯃꯝ ꯂꯥꯞ ꯊꯥꯛ
| ꯄꯥꯏꯞꯀꯤ ꯗꯥꯏꯃꯤꯇꯔ | ꯃꯦꯛꯁꯤꯃꯝ ꯂꯥꯞ ꯊꯥꯛ |
|---|---|
| 300–600 mm | 40 m |
| 700–1,000 mm | 100 m |
| 1,050–1,400 mm | 150 m |
| 1,500 mm ꯑꯃꯁꯨꯡ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ | 300 m |
ꯍꯧꯔꯛꯐꯝ: CPHEEO 2019 Table 11.5꯫ ꯃꯦꯟꯍꯣꯜꯒꯤ ꯁꯥꯏꯖꯁꯤꯡ, ꯗ꯭ꯔꯣꯞꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯀꯚꯔꯁꯤꯡ: ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.12꯫
ꯃꯃꯤ 6.3 — ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯦꯛꯁꯟꯁꯤꯡ: ꯐ꯭ꯔꯤꯕꯣꯔꯗ, ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁ ꯑꯃꯁꯨꯡ ꯆꯡꯂꯛꯄꯒꯤ ꯂꯝꯕꯤ꯫ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ ꯑꯅꯧꯅꯥ ꯁꯦꯝꯕ ꯗ꯭ꯔꯣꯏꯡ, CPHEEO, Manual on Storm Water Drainage Systems (2019), Tables 5.3 and 5.12, ꯑꯃꯁꯨꯡ IRC:SP:50-2013-ꯗꯒꯤ ꯍꯣꯡꯗꯣꯛꯂꯒꯥ ꯂꯧꯈꯤꯕ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. n-ꯒꯤ ꯚꯦꯜꯌꯨꯁꯤꯡ ꯑꯁꯤ CPHEEO (2019) Table 5.1-ꯒꯤꯅꯤ꯫ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕ ꯃꯤꯅꯤꯃꯝ ꯗꯤꯖꯥꯏꯟ ꯚꯦꯜꯌꯨꯁꯤꯡ ꯑꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ; ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯃꯈꯣꯌ ꯊꯝꯂꯤ, ꯃꯔꯝꯗꯤ CPHEEO-ꯅꯥ ꯁ꯭ꯄꯟ ꯄꯥꯏꯞꯁꯤꯡꯒꯤ 0.011-ꯒꯤ ꯚꯦꯜꯌꯨ ꯑꯁꯤ "ꯃꯦꯅꯨꯐꯦꯛꯆꯔꯔꯅꯥ ꯄꯤꯕꯒꯨꯝꯅꯥ ꯂꯧꯕ ꯌꯥꯏ" ("may be taken as given by the manufacturer") ꯍꯥꯌꯅꯥ ꯅꯣꯠ ꯇꯧꯔꯤ꯫ ꯃꯁꯤ ꯁꯦꯡꯂꯕ ꯄꯥꯏꯞꯀꯤ ꯚꯦꯜꯌꯨꯅꯤ, ꯑꯃꯁꯨꯡ ꯃꯅꯤꯄꯨꯔꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯅꯥ ꯂꯩꯃꯨ ꯑꯃꯁꯨꯡ ꯁꯣꯂꯤꯗ ꯋꯦꯁ꯭ꯠ ꯌꯥꯝꯅꯥ ꯄꯨꯏ꯫ 0.6 m/s-ꯒꯤ ꯃꯤꯅꯤꯃꯝ ꯚꯦꯂꯣꯁꯤꯇꯤ ꯑꯁꯤ CPHEEO-ꯒꯤꯅꯤ (Table 5.2), 0.09 mm-ꯒꯤ ꯂꯩꯉꯣꯏ ꯄꯨꯕꯗ ꯌꯨꯝꯐꯝ ꯑꯣꯏꯕ (§5.3.1)꯫ ꯄꯥꯏꯞꯁꯤꯡꯒꯤ 0.9 m/s-ꯒꯤ ꯚꯦꯜꯌꯨ ꯑꯁꯤ ꯍꯦꯟꯅꯥ ꯀꯟꯏ, ꯃꯔꯝꯗꯤ ꯂꯩꯃꯨꯅꯥ ꯃꯄꯨꯟꯕ ꯄꯥꯏꯞ ꯑꯃꯥ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯨꯝꯅꯥ ꯂꯥꯏꯅꯥ ꯁꯦꯡꯗꯣꯛꯄ ꯌꯥꯗꯦ꯫ 3.0 m/s-ꯒꯤ ꯃꯦꯛꯁꯤꯃꯝ ꯑꯁꯤ CPHEEO Table 5.2 (WPCF/ASCE 1982)-ꯗꯒꯤꯅꯤ꯫ 0.8-ꯒꯤ ꯐ꯭ꯔꯨꯗ ꯂꯤꯃꯤꯠ ꯑꯁꯤ CPHEEO §5.3-ꯗꯒꯤꯅꯤ, ꯃꯁꯤꯅꯥ ꯏꯁꯤꯡꯒꯤ ꯃꯊꯛ ꯑꯁꯤ ꯆꯦꯠꯄ ꯂꯩꯇꯕ ꯑꯣꯏꯔꯀꯄꯅꯥ ꯀ꯭ꯔꯤꯇꯤꯀꯦꯜ ꯐ꯭ꯂꯣ ꯊꯥꯗꯣꯛꯅꯕ ꯄꯥꯎꯇꯥꯛ ꯄꯤꯔꯤ꯫
ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤ 0.6 m × 0.6 m-ꯒꯤ ꯃꯤꯅꯤꯃꯝ ꯑꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯃꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ ꯃꯁꯤꯗꯒꯤ ꯌꯧꯕ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯀꯚꯔꯒꯤ ꯍꯥꯡꯕ ꯃꯐꯝ ꯑꯃꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯈꯨꯠꯅꯥ ꯅꯠꯔꯒꯥ ꯑꯄꯤꯛꯄ ꯃꯦꯁꯤꯅꯁꯤꯡꯅꯥ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯛꯄ ꯌꯥꯗꯦ, ꯑꯃꯁꯨꯡ ꯂꯩꯃꯨꯅꯥ ꯃꯄꯨꯟꯕ, ꯆꯡꯕ ꯌꯥꯗꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯃꯦ 2024 ꯑꯃꯁꯨꯡ ꯃꯦ–ꯖꯨꯟ 2025-ꯒꯤ ꯏꯝꯐꯥꯜꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯁꯤꯡꯒꯤ ꯃꯇꯨꯡꯗ ꯍꯟꯖꯤꯟ ꯍꯟꯖꯤꯟ ꯐꯡꯂꯛꯄ ꯑꯃꯅꯤ, "ꯂꯩꯔꯤꯕ ꯏꯔꯝ … ꯑꯁꯤꯁꯨ ꯐꯕ ꯐꯤꯚꯝꯗ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯄ꯭ꯔꯥꯏꯃꯔꯤ ꯈꯣꯡꯕꯥꯟꯗ ꯆꯨꯝꯅꯥ ꯁꯝꯃꯤꯟꯅꯗꯦ꯫ ꯏꯔꯝ ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯂꯤꯉ꯭ꯛꯁꯤꯡ ꯃꯥꯡꯂꯤ … ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯀꯨꯞꯂꯦ" ("existing drainage … is also not in good condition and is not properly connected to the primary drain. Drainage system links are missing … the drains are clogged") (AIIB, 2024) ꯍꯥꯌꯔꯤꯕ ꯁꯍꯔ ꯑꯃꯗ, ꯀꯩꯊꯦꯜꯒꯤ ꯋꯦꯁ꯭ꯠ ꯑꯁꯤ ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥꯗ ꯊꯥꯗꯣꯀꯏ, "ꯃꯁꯤꯅꯥ ꯆꯍꯤ ꯄꯨꯝꯕꯗ ꯆꯦꯟꯗꯕ ꯏꯁꯤꯡ ꯄꯨꯟꯁꯤꯟꯕ ꯑꯃꯥ ꯁꯦꯝꯃꯤ" ("which creates a stagnant pool all along the year") (ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ), ꯑꯃꯁꯨꯡ ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥ ꯀꯨꯞꯄꯅꯥ ꯖꯨꯂꯥꯏ 2024-ꯗ ꯅꯥꯒꯥꯔꯝ, ꯂꯥꯏꯐꯝ ꯈꯨꯅꯧ ꯑꯃꯁꯨꯡ ꯂꯥꯏꯔꯤꯛꯌꯦꯡꯕꯝ ꯂꯩꯀꯥꯏꯗ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯄꯨꯔꯛꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ); AIIB ꯄ꯭ꯔꯣꯖꯦꯛꯠꯅꯥ ꯍꯧꯖꯤꯛ ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯒꯤ ꯂꯝꯕꯤꯁꯤꯡꯒꯤ ꯃꯅꯥꯛꯇ "ꯃꯅꯥꯛ ꯑꯅꯤꯃꯛꯇ ꯀꯚꯔ ꯇꯧꯔꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ 547 km" ("547 km of both side stormwater covered drains") ꯁꯥꯒꯠꯀꯗꯕꯅꯤ (AIIB, 2024)꯫ 0.6 m-ꯒꯤ ꯃꯤꯅꯤꯃꯝ ꯀꯚꯔ ꯑꯁꯤ CPHEEO (2019)-ꯒꯤ ꯊꯕꯛ ꯇꯧꯔꯕ ꯄꯥꯏꯞ-ꯗꯤꯖꯥꯏꯟ ꯀꯝꯞꯌꯨꯇꯦꯁꯟ ꯁꯤꯠꯇ (Part A, Chapter 5) ꯁꯤꯖꯤꯟꯅꯔꯤꯕ ꯚꯦꯜꯌꯨꯅꯤ꯫ ꯀꯦꯔꯤꯌꯦꯖꯋꯦꯁꯤꯡꯒꯤ ꯃꯈꯥꯗ 0.9 m-ꯒꯤ ꯀꯚꯔ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫
ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁꯀꯤ ꯚꯦꯜꯌꯨꯁꯤꯡ (ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤꯗꯃꯛ 75 mm ꯅꯠꯔꯒꯥ 10%, ꯑꯆꯧꯕ ꯄꯥꯏꯞꯁꯤꯡꯒꯤꯗꯃꯛ 5%) ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ ꯏꯟꯗꯤꯌꯥꯒꯤ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯑꯃꯠꯇꯅꯥ ꯗꯤꯖꯥꯏꯟꯒꯤꯗꯃꯛ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁ ꯑꯃꯥ ꯊꯝꯗꯦ꯫ ꯏꯝꯐꯥꯜꯒꯤ ꯊꯦꯡꯅꯈꯤꯕꯗꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯆꯍꯤꯒꯤ ꯃꯇꯝ ꯌꯥꯝꯅꯥ ꯂꯩꯃꯨꯅꯥ ꯁꯔꯨꯛ ꯈꯔ ꯃꯄꯨꯟꯅꯥ ꯆꯠꯂꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯁꯦꯡꯂꯕ ꯁꯦꯛꯁꯟ ꯑꯃꯒꯤꯗꯃꯛ ꯊꯤꯔꯕ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯃꯅꯥ ꯑꯆꯨꯝꯕ ꯀꯦꯄꯥꯁꯤꯇꯤꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯎꯠꯂꯤ꯫
CPHEEO-ꯒꯤ ꯐ꯭ꯔꯤꯕꯣꯔꯗꯀꯤ ꯇꯦꯕꯜ (Table 5.3)-ꯅꯥ ꯑꯍꯥꯅꯕ ꯔꯣ ꯑꯁꯤ "ꯕꯦꯗ ꯄꯥꯛꯄ 300 mm-ꯗꯒꯤ ꯍꯦꯟꯕ" ("Beyond 300 mm bed width") ꯍꯥꯌꯅꯥ ꯐꯣꯡꯗꯣꯛꯂꯤ꯫ ꯑꯅꯤꯁꯨꯕ ꯔꯣ ("ꯕꯦꯗ ꯄꯥꯛꯄ 300 mm-ꯗꯒꯤ ꯍꯦꯟꯕ ꯑꯃꯁꯨꯡ 900 mm ꯐꯥꯎꯕ" ["Beyond 300 mm & up to 900 mm"])-ꯒꯥ ꯂꯣꯌꯅꯅ ꯄꯥꯔꯕꯗꯤ, ꯑꯍꯥꯅꯕ ꯔꯣ ꯑꯁꯤꯒꯤ ꯑꯔꯊꯗꯤ "300 mm ꯐꯥꯎꯕ" ("up to 300 mm") ꯑꯣꯏꯒꯗꯕꯅꯤ; ꯇꯦꯕꯜ 6.7 ꯑꯁꯤ ꯃꯑꯣꯡ ꯑꯗꯨꯅꯥ ꯏꯔꯤ꯫ CPHEEO-ꯒꯤ ꯃꯦꯟꯍꯣꯜꯒꯤ ꯂꯥꯞ ꯊꯥꯛꯀꯤ ꯇꯦꯕꯜ (Table 11.5)-ꯅꯥ ꯊꯦꯡꯅꯅꯕ ꯔꯦꯟꯖꯁꯤꯡ (700–1,050 mm ꯑꯃꯁꯨꯡ 1,000–1,400 mm) ꯄꯤꯔꯤ; ꯇꯦꯕꯜ 6.8-ꯅꯥ 1,050 mm ꯑꯁꯤ 150 m-ꯒꯤ ꯀ꯭ꯂꯥꯁꯇ ꯊꯝꯗꯨꯅꯥ ꯊꯦꯡꯅꯅꯕ ꯑꯗꯨ ꯂꯧꯊꯣꯛꯂꯤ꯫
6.8 ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯒ꯭ꯔꯦꯗ ꯂꯥꯏꯟ
6.8.1 HGL ꯑꯦꯅꯥꯂꯥꯏꯁꯤꯁ. ꯄꯥꯏꯞ ꯑꯃꯁꯨꯡ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯅꯦꯠꯋꯔꯛ ꯈꯨꯗꯤꯡꯃꯛꯀꯤꯗꯃꯛ, ꯗꯤꯖꯥꯏꯅꯔꯅꯥ ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯏꯚꯦꯟꯠ ꯑꯃꯁꯨꯡ ꯆꯦꯛ ꯏꯚꯦꯟꯠꯀꯤꯗꯃꯛ HGL ꯑꯁꯤ ꯑꯥꯎꯠꯐꯣꯜꯗꯒꯤ ꯍꯧꯗꯨꯅꯥ ꯃꯊꯛ ꯊꯡꯕ ꯃꯥꯏꯀꯩꯗ ꯊꯤꯒꯗꯕꯅꯤ꯫ ꯑꯦꯅꯥꯂꯥꯏꯁꯤꯁ ꯑꯁꯤꯗ ꯐ꯭ꯔꯤꯛꯁꯟ ꯂꯣꯁꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯖꯉ꯭ꯀꯁꯟꯁꯤꯡ, ꯃꯦꯟꯍꯣꯜꯁꯤꯡ, ꯀꯣꯏꯕ ꯃꯐꯝꯁꯤꯡ, ꯏꯟꯂꯦꯠꯁꯤꯡ, ꯑꯥꯎꯠꯂꯦꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯒꯦꯠꯁꯤꯡꯗ ꯂꯩꯕ ꯂꯣꯁꯁꯤꯡ ꯌꯥꯎꯒꯗꯕꯅꯤ꯫
6.8.2 ꯍꯧꯕꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯂꯦꯚꯦꯜ. ꯑꯥꯎꯠꯐꯣꯜꯗ ꯍꯧꯕꯒꯤ (ꯇꯦꯜꯋꯥꯇꯔ) ꯂꯦꯚꯦꯜ ꯑꯁꯤ ꯃꯈꯥꯒꯤ ꯑꯅꯤꯒꯤ ꯃꯔꯛꯇ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕ ꯑꯗꯨ ꯑꯣꯏꯒꯗꯕꯅꯤ:
- (a) ꯁꯔꯨꯛ 5-ꯒꯤ ꯇꯦꯜꯋꯥꯇꯔ ꯂꯦꯚꯦꯜ: ꯇꯥꯏꯗꯦꯜ ꯑꯥꯎꯠꯐꯣꯜꯁꯤꯡꯗ ꯃꯥꯏꯅꯔ-ꯁꯤꯁ꯭ꯇꯦꯝ ꯗꯤꯖꯥꯏꯟꯒꯤꯗꯃꯛ ꯃꯤꯟ ꯍꯥꯏ ꯋꯥꯇꯔ ꯁ꯭ꯞꯔꯤꯡꯁ (MHWS) ꯑꯃꯁꯨꯡ +0.3 m-ꯒꯤ ꯁꯤ-ꯂꯦꯚꯦꯜ ꯑꯦꯂꯥꯎꯑꯦꯟꯁ, ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯑꯥꯎꯠꯐꯣꯜꯁꯤꯡꯗ ꯀꯣꯏꯟꯁꯤꯗꯦꯟꯠ ꯏꯚꯦꯟꯠꯀꯤꯗꯃꯛ ꯏꯁꯤꯡ ꯂꯧꯕ ꯈꯣꯡꯕꯥꯟ, ꯇꯨꯔꯦꯜ ꯅꯠꯔꯒꯥ ꯄꯨꯈ꯭ꯔꯤꯒꯤ ꯂꯦꯚꯦꯜ; ꯑꯃꯁꯨꯡ
- (b) ꯏꯁꯤꯡ ꯂꯧꯕ ꯏꯁꯤꯡ ꯑꯗꯨ ꯍꯦꯟꯅꯥ ꯅꯦꯝꯕ ꯃꯐꯝꯗ, ꯑꯥꯎꯠꯂꯦꯠ ꯄꯥꯏꯞꯇ ꯀ꯭ꯔꯤꯇꯤꯀꯦꯜ ꯗꯦꯞꯊ ꯑꯃꯁꯨꯡ ꯄꯥꯏꯞꯀꯤ ꯗꯥꯏꯃꯤꯇꯔꯗꯒꯤ ꯊꯤꯔꯕ ꯂꯦꯚꯦꯜ, (dc + D)/2꯫
6.8.3 ꯃꯥꯏꯅꯔ-ꯏꯚꯦꯟꯠꯀꯤ ꯂꯤꯃꯤꯠ. ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯏꯚꯦꯟꯠꯇ, HGL ꯑꯁꯤ ꯏꯟꯂꯦꯠ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯔꯤꯝ (rim) ꯑꯃꯁꯨꯡ ꯃꯦꯟꯍꯣꯜ ꯑꯃꯁꯨꯡ ꯑꯦꯛꯁꯦꯁ ꯆꯦꯝꯕꯔ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯀꯚꯔ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 0.3 m ꯃꯈꯥꯗ ꯂꯩꯒꯗꯕꯅꯤ꯫
6.8.4 ꯆꯦꯛ-ꯏꯚꯦꯟꯠ ꯑꯃꯁꯨꯡ 1%-ꯒꯤ ꯂꯤꯃꯤꯠ. ꯆꯦꯛ ꯏꯚꯦꯟꯠ ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯏꯚꯦꯟꯠꯇ, HGL ꯑꯁꯤ ꯏꯟꯂꯦꯠꯀꯤ ꯔꯤꯝꯁꯤꯡꯗꯒꯤ ꯋꯥꯡꯅꯥ ꯍꯦꯟꯒꯠꯄ ꯌꯥꯏ꯫ ꯃꯇꯝ ꯑꯗꯨꯗ ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯊꯥꯗꯣꯛꯂꯤꯕ ꯏꯁꯤꯡ ꯑꯗꯨ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯅꯥ ꯇꯦꯕꯜ 6.2-ꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ ꯄꯨꯒꯗꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯠꯇꯗ ꯆꯡꯂꯣꯏꯗꯕꯅꯤ꯫ ꯏꯚꯦꯟꯠ ꯑꯁꯤꯁꯤꯡꯗ ꯂꯩꯃꯥꯏꯒꯤ ꯃꯊꯛꯇ ꯁꯔꯆꯥꯔꯖ ꯑꯣꯏꯕ ꯌꯥꯕ ꯃꯦꯟꯍꯣꯜꯁꯤꯡꯗ ꯕꯣꯜꯠ ꯇꯧꯔꯕ ꯅꯠꯔꯒꯥ ꯂꯣꯛ ꯇꯧꯔꯕ ꯀꯚꯔꯁꯤꯡ ꯂꯩꯒꯗꯕꯅꯤ (ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.12)꯫
6.8.5 ꯁ꯭ꯇ꯭ꯔꯛꯆꯔꯒꯤ ꯂꯣꯁꯁꯤꯡ. ꯃꯦꯟꯍꯣꯜꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯖꯉ꯭ꯀꯁꯟꯁꯤꯡꯗ ꯂꯩꯕ ꯂꯣꯁꯁꯤꯡ ꯑꯁꯤ FHWA HEC-22 (2009 ꯅꯠꯔꯒꯥ 2024-ꯒꯤ ꯑꯦꯗꯤꯁꯟ)-ꯒꯤ ꯑꯦꯅꯔꯖꯤꯗ ꯌꯨꯝꯐꯝ ꯑꯣꯏꯕ ꯑꯦꯛꯁꯦꯁ-ꯍꯣꯜ ꯃꯦꯊꯗꯅꯥ (access-hole method), ꯅꯠꯔꯒꯥ ꯑꯦꯞꯔꯨꯚ ꯇꯧꯔꯕ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯃꯣꯗꯦꯜ ꯑꯃꯗ ꯂꯩꯕ ꯃꯥꯟꯅꯕ ꯊꯧꯑꯣꯡ ꯑꯃꯅꯥ ꯊꯤꯒꯗꯕꯅꯤ꯫ HEC-22-ꯒꯤ ꯀꯣꯑꯦꯐꯤꯁꯤꯌꯦꯟꯠꯁꯤꯡ ꯂꯩꯕ ꯂꯥꯏꯊꯣꯛꯍꯟꯕ ꯂꯣꯁ-ꯀꯣꯑꯦꯐꯤꯁꯤꯌꯦꯟꯠ ꯃꯦꯊꯗ ꯑꯃꯥ (h = K V²/2g) 16 ha-ꯗꯒꯤ ꯍꯟꯊꯕ ꯇꯤꯌꯔ B ꯅꯦꯠꯋꯔꯛꯁꯤꯡꯒꯤꯗꯃꯛ ꯁꯤꯖꯤꯟꯅꯕ ꯌꯥꯏ꯫
6.8.6 ꯏꯟꯚꯔꯠ ꯑꯃꯁꯨꯡ ꯁꯣꯐꯤꯠꯀꯤ ꯂꯦꯚꯦꯜꯁꯤꯡ. ꯃꯦꯟꯍꯣꯜ ꯑꯃꯗ ꯄꯥꯏꯞꯀꯤ ꯁꯥꯏꯖ ꯍꯦꯟꯒꯠꯂꯀꯄ ꯃꯐꯝꯗ, ꯆꯡꯂꯛꯂꯤꯕ ꯑꯃꯁꯨꯡ ꯊꯣꯛꯂꯛꯂꯤꯕ ꯄꯥꯏꯞꯁꯤꯡꯒꯤ ꯁꯣꯐꯤꯠꯁꯤꯡ (ꯀ꯭ꯔꯥꯎꯟꯁꯤꯡ) ꯑꯁꯤ ꯃꯥꯟꯅꯍꯅꯒꯗꯕꯅꯤ, ꯅꯠꯔꯒꯥ ꯊꯣꯛꯂꯛꯂꯤꯕ ꯁꯣꯐꯤꯠ ꯑꯁꯤ ꯍꯦꯟꯅꯥ ꯅꯦꯝꯅꯥ ꯊꯝꯒꯗꯕꯅꯤ꯫ ꯊꯣꯛꯂꯛꯂꯤꯕ ꯏꯟꯚꯔꯠ ꯑꯁꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯅꯦꯝꯕ ꯆꯡꯂꯛꯂꯤꯕ ꯏꯟꯚꯔꯠꯇꯒꯤ ꯋꯥꯡꯔꯣꯏꯗꯕꯅꯤ꯫ ꯃꯦꯟꯍꯣꯜꯁꯤꯡꯗ ꯂꯩꯕ ꯃꯊꯛꯇꯒꯤ ꯃꯈꯥꯗ ꯆꯨꯃꯊꯣꯛꯅꯥ ꯇꯥꯕ ꯗ꯭ꯔꯣꯞꯁꯤꯡ ꯑꯁꯤꯅꯥ ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.12 ꯃꯇꯨꯡ ꯏꯟꯅꯒꯗꯕꯅꯤ꯫
6.8.7 ꯒꯦꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯚꯥꯜꯚꯁꯤꯡ. ꯍꯥꯡꯗꯣꯛꯂꯕ ꯐꯤꯚꯝꯗ ꯂꯩꯕ ꯐ꯭ꯂꯦꯞ ꯒꯦꯠꯁꯤꯡ (flap gate) ꯑꯃꯁꯨꯡ ꯅꯟ-ꯔꯤꯇꯔꯟ ꯚꯥꯜꯚꯁꯤꯡꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯍꯦꯗ ꯂꯣꯁ ꯑꯁꯤ HGL-ꯗ ꯌꯥꯎꯒꯗꯕꯅꯤ (ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.10)꯫
6.8.8 ꯄ꯭ꯔꯥꯏꯚꯦꯠ ꯀꯅꯦꯛꯁꯟꯁꯤꯡ. 1%-ꯒꯤ HGL ꯑꯁꯤ ꯕꯤꯜꯗꯤꯡꯒꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯅꯦꯝꯕ ꯏꯔꯝꯒꯤ ꯐꯤꯇꯤꯡꯗꯒꯤ ꯋꯥꯡꯅꯥ ꯂꯩꯕ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯁꯝꯃꯤꯟꯅꯕ ꯕꯤꯜꯗꯤꯡꯒꯤ ꯏꯔꯝꯗ ꯅꯟ-ꯔꯤꯇꯔꯟ ꯚꯥꯜꯚ ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. ꯃꯥꯏꯅꯔ-ꯏꯚꯦꯟꯠꯀꯤ HGL ꯑꯃꯁꯨꯡ ꯏꯟꯂꯦꯠꯀꯤ ꯔꯤꯝꯒꯤ ꯃꯔꯛꯇ ꯂꯩꯕ 0.3 m-ꯒꯤ ꯂꯥꯞ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ ꯃꯁꯤꯅꯥ ꯃꯣꯗꯦꯜ ꯑꯃꯅꯥ ꯍꯟꯊꯅꯥ ꯊꯤꯕ ꯂꯣꯁꯁꯤꯡꯒꯤꯗꯃꯛ ꯃꯥꯔꯖꯤꯟ ꯑꯃꯥ ꯊꯝꯃꯤ, ꯑꯃꯁꯨꯡ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯁꯤ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯔꯕ ꯏꯚꯦꯟꯠꯇ ꯏꯟꯂꯦꯠꯁꯤꯡꯗꯒꯤ ꯏꯁꯤꯡ ꯄꯨꯊꯣꯛꯂꯛꯄ ꯊꯤꯡꯏ꯫ ꯃꯅꯤꯄꯨꯔꯗ ꯇꯝꯄꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟ ꯌꯥꯝꯅꯥ ꯇꯨꯔꯦꯜꯒꯤ ꯄꯟ ꯑꯃꯗ ꯂꯩꯕ ꯒꯦꯠ ꯑꯃꯗ ꯂꯣꯏꯏ, ꯃꯁꯤꯒꯤ ꯃꯇꯨꯡꯗ ꯃꯣꯟꯁꯨꯟꯗ ꯅꯨꯃꯤꯠ ꯀꯌꯥꯒꯤ ꯃꯇꯝ ꯇꯨꯔꯦꯜ ꯑꯁꯤ ꯈꯣꯡꯕꯥꯟꯗꯒꯤ ꯋꯥꯡꯅꯥ ꯂꯩꯏ, ꯅꯠꯔꯒꯥ ꯃꯇꯝ ꯄꯨꯝꯕꯗ ꯋꯥꯡꯅꯥ ꯂꯩꯕ ꯂꯣꯛꯇꯥꯛꯇ, ꯅꯠꯔꯒꯥ ꯃꯃꯥꯡꯗꯒꯤ ꯃꯄꯨꯟꯕ ꯑꯣꯏꯔꯦꯕ ꯄꯥꯠ ꯑꯃꯗ ꯂꯣꯏꯏ (ꯀ꯭ꯂꯣꯖ 5.8.5)꯫ ꯃꯤꯅꯨꯊꯣꯡꯗ (Minuthong) ꯏꯝꯐꯥꯜ ꯇꯨꯔꯦꯜꯒꯤ ꯐ꯭ꯂꯗ ꯂꯦꯚꯦꯜ 786.900 m ꯑꯃꯁꯨꯡ ꯍꯥꯏꯌꯦꯁ꯭ꯠ ꯐ꯭ꯂꯗ ꯂꯦꯚꯦꯜ 788.400 m ꯂꯩ (WRD, ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ), ꯁꯍꯔꯒꯤ ꯂꯩꯃꯥꯏ 790 m ꯃꯔꯣꯜ ꯂꯩꯕꯒꯥ ꯆꯥꯡꯗꯝꯅꯕꯗ (AIIB, 2024); "ꯁꯍꯔ ꯑꯁꯤ ꯏꯝꯐꯥꯜ ꯇꯨꯔꯦꯜꯒꯤ ꯍꯥꯏꯌꯦꯁ꯭ꯠ ꯐ꯭ꯂꯗ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯅꯦꯝꯃꯤ" ("the town is below the high flood level of Imphal river") (ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ); ꯑꯃꯁꯨꯡ 15 ꯁꯦꯞꯇꯦꯝꯕꯔ 2025-ꯗ ꯂꯤꯂꯣꯡꯗ ꯂꯩꯕ ꯇꯨꯔꯦꯜ ꯑꯃꯁꯨꯡ ꯏꯊꯥꯏꯗ (Ithai) ꯂꯩꯕ ꯃꯅꯤꯄꯨꯔ ꯇꯨꯔꯦꯜ ꯑꯁꯤ ꯃꯈꯣꯌꯒꯤ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯍꯥꯏꯌꯦꯁ꯭ꯠ ꯐ꯭ꯂꯗ ꯂꯦꯚꯦꯜꯁꯤꯡꯗꯒꯤ ꯋꯥꯡꯅꯥ ꯂꯩꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ)꯫ ꯔꯤꯁꯔꯆꯀꯤ ꯃꯇꯝꯗ ꯁ꯭ꯇꯦꯠ ꯑꯁꯤꯗ ꯂꯩꯕ ꯑꯥꯎꯠꯐꯣꯜ ꯑꯃꯠꯇꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯂꯦꯚꯦꯜ ꯐꯡꯈꯤꯗꯦ꯫ HGL ꯑꯁꯤ ꯐ꯭ꯔꯤ ꯑꯥꯎꯠꯐꯣꯜ ꯑꯃꯗꯒꯤ ꯍꯧꯔꯕ, ꯅꯠꯔꯒꯥ ꯃꯁꯤꯒꯤ ꯑꯔꯣꯏꯕꯗ ꯂꯩꯕ ꯇꯨꯔꯦꯜ, ꯊꯤꯡꯂꯕ ꯒꯦꯠ, ꯂꯦꯛ ꯅꯠꯔꯒꯥ ꯃꯄꯨꯟꯕ ꯄꯥꯠ ꯌꯥꯎꯗꯅꯥ ꯁꯥꯡꯕ ꯑꯃꯃꯃꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ ꯊꯤꯔꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯅꯥ ꯃꯑꯣꯡ ꯑꯗꯨꯃꯛꯇ ꯐꯦꯜ ꯇꯧꯏ꯫ ꯁꯔꯨꯛ 5-ꯒꯤ ꯇꯥꯏꯗꯦꯜ ꯇꯦꯜꯋꯥꯇꯔꯒꯥ ꯂꯣꯌꯅꯅ ꯑꯥꯎꯠꯐꯣꯜꯗꯒꯤ ꯊꯤꯔꯕ HGL ꯑꯃꯅꯥ ꯑꯔꯥꯟꯕ ꯑꯗꯨꯁꯤꯡ ꯗꯤꯖꯥꯏꯟꯒꯤ ꯁ꯭ꯇꯦꯖꯇ ꯎꯠꯂꯤ꯫ MHWS ꯑꯃꯁꯨꯡ 0.3 m-ꯒꯤ ꯍꯧꯕꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯁꯤ CPHEEO (2019) Table 6.2-ꯗꯒꯤꯅꯤ꯫ ꯑꯦꯛꯁꯦꯁ-ꯍꯣꯜ ꯃꯦꯊꯗ ꯑꯁꯤ 2009-ꯒꯤ ꯑꯦꯗꯤꯁꯟꯗꯒꯤ ꯍꯧꯔꯒꯥ HEC-22-ꯗ ꯁꯟꯗꯣꯛꯂꯤ꯫
6.9 ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ: ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯁꯤꯡ, ꯏꯖꯃꯦꯟꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚꯁꯤꯡ
6.9.1 ꯃꯔꯨꯑꯣꯏꯕ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯣꯏꯕ ꯂꯝꯕꯤꯁꯤꯡ. ꯂꯝꯕꯤꯁꯤꯡ ꯑꯁꯤ 1% AEP-ꯒꯤ ꯃꯦꯖꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯂꯝꯕꯤꯒꯤ ꯔꯤꯖꯔꯚꯀꯤ ꯃꯅꯥꯛꯇ ꯊꯤꯡꯖꯤꯜꯂꯣꯏꯗꯅꯥ ꯏꯁꯤꯡ ꯂꯧꯕ ꯋꯥꯇꯔꯋꯦ ꯑꯃꯗ ꯄꯨꯕ ꯃꯑꯣꯡꯗ ꯒ꯭ꯔꯦꯗ ꯇꯧꯒꯗꯕꯅꯤ, ꯀ꯭ꯂꯣꯖ 6.10-ꯒꯤ ꯃꯈꯥꯗ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯔꯕ ꯁꯦꯒꯁꯤꯡ ꯅꯠꯇꯕꯗꯤ꯫
6.9.2 ꯂꯝꯕꯤꯁꯤꯡꯒꯤ ꯃꯄꯥꯟꯗ ꯂꯩꯕ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯁꯤꯡ. ꯃꯦꯖꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯂꯝꯕꯤ ꯑꯃꯅꯥ ꯂꯝꯕꯤꯒꯤ ꯔꯤꯖꯔꯚ ꯊꯥꯗꯣꯛꯂꯕ ꯃꯐꯝꯗ, ꯃꯁꯤ:
- (a) ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯗ, ꯂꯦꯑꯥꯎꯠ ꯑꯃꯒꯤ ꯑꯣꯄꯟ ꯁ꯭ꯄꯦꯁꯇ, ꯅꯠꯔꯒꯥ ꯂꯦꯑꯥꯎꯠ ꯑꯦꯞꯔꯨꯚꯦꯜ ꯑꯃꯁꯨꯡ ꯇꯥꯏꯇꯜꯗ ꯔꯦꯀꯣꯔꯗ ꯇꯧꯔꯕ ꯏꯖꯃꯦꯟꯠ ꯑꯃꯗ ꯂꯩꯒꯗꯕꯅꯤ;
- (b) ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 1% AEP-ꯒꯤ ꯐ꯭ꯂꯣꯒꯤ ꯃꯊꯛꯀꯤ ꯄꯥꯛꯄ ꯑꯃꯁꯨꯡ ꯃꯥꯏꯀꯩ ꯈꯨꯗꯤꯡꯃꯛꯇ 0.5 m ꯄꯥꯛꯄ ꯑꯣꯏꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ 3.0 m-ꯗꯒꯤ ꯍꯟꯊꯔꯣꯏꯗꯕꯅꯤ;
- (c) ꯐ꯭ꯂꯣ ꯊꯤꯡꯒꯅꯤꯕ ꯕꯤꯜꯗꯤꯡꯁꯤꯡ, ꯀꯝꯄꯥꯎꯟꯗ ꯋꯣꯜꯁꯤꯡ, ꯐꯦꯟꯁꯁꯤꯡ, ꯐꯤꯜ, ꯊꯝꯂꯕ ꯄꯣꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯄꯥꯝꯕꯤ ꯊꯥꯕꯗꯒꯤ ꯂꯥꯞꯅꯥ ꯊꯝꯒꯗꯕꯅꯤ;
- (d) ꯑꯥꯎꯠꯂꯦꯠ ꯂꯩꯇꯕ ꯁꯦꯒ ꯑꯃꯠꯇꯥ ꯂꯩꯇꯅꯥ ꯂꯦꯞꯇꯅꯥ ꯅꯦꯝꯊꯔꯀꯄ ꯒ꯭ꯔꯦꯗ ꯑꯃꯗ ꯊꯝꯒꯗꯕꯅꯤ; ꯑꯃꯁꯨꯡ
- (e) ꯇꯦꯕꯜ 6.3-ꯒꯤ ꯍꯖꯥꯔꯗꯀꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯒꯗꯕꯅꯤ꯫
6.9.3 ꯀꯝꯄꯥꯎꯟꯗ ꯋꯣꯜꯁꯤꯡ. ꯃꯦꯞ ꯇꯧꯔꯕ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯑꯃꯗ ꯀꯣꯛꯅꯥ ꯀꯝꯄꯥꯎꯟꯗ ꯋꯣꯜ ꯅꯠꯔꯒꯥ ꯐꯦꯟꯁ ꯑꯃꯥ ꯁꯥꯔꯣꯏꯗꯕꯅꯤ꯫ ꯋꯣꯜ ꯑꯃꯅꯥ ꯃꯁꯤ ꯀꯣꯛꯅꯥ ꯆꯠꯀꯗꯕ ꯑꯣꯏꯔꯕꯗꯤ, ꯃꯁꯤꯗ 50% ꯕ꯭ꯂꯣꯀꯦꯖꯒꯥ ꯂꯣꯌꯅꯅ 1% AEP-ꯒꯤ ꯐ꯭ꯂꯣ ꯆꯠꯍꯅꯕ ꯃꯄꯨꯡ ꯐꯥꯕ ꯑꯦꯔꯤꯌꯥ ꯂꯩꯕ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡ ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯊꯛ ꯊꯡꯕ ꯃꯐꯝꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯁꯤ ꯁꯔꯨꯛ ꯑꯁꯤꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯍꯟꯗꯅꯥ꯫
6.9.4 ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤ ꯃꯅꯥꯛꯇ ꯆꯡꯂꯛꯄꯒꯤ ꯂꯝꯕꯤ. ꯃꯊꯛꯀꯤ ꯄꯥꯛꯄ 2 m ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯂꯩꯔꯥꯏ ꯑꯃꯒꯤ ꯃꯅꯥꯛꯇ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 3.5 m ꯄꯥꯛꯄ ꯃꯦꯟꯇꯦꯅꯦꯟꯁꯀꯤ ꯑꯦꯛꯁꯦꯁ ꯁ꯭ꯇ꯭ꯔꯤꯞ ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯁꯤ 500 m-ꯗꯒꯤ ꯍꯦꯟꯗꯕ ꯂꯥꯞ ꯊꯥꯛꯇ ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯕꯤ ꯑꯃꯗ ꯁꯝꯃꯤꯟꯅꯒꯗꯕꯅꯤ꯫
6.9.5 ꯁꯞꯂꯥꯏ ꯆꯦꯅꯦꯜꯁꯤꯡ, ꯁꯔꯞꯂꯁ ꯀꯣꯔꯁꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯄꯨꯈ꯭ꯔꯤꯁꯤꯡ. ꯄꯨꯈ꯭ꯔꯤꯒꯤ ꯁꯞꯂꯥꯏ ꯆꯦꯅꯦꯜꯁꯤꯡ (supply channel) ꯑꯃꯁꯨꯡ ꯁꯔꯞꯂꯁ ꯀꯣꯔꯁꯁꯤꯡ (surplus course) ꯑꯁꯤ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯁꯔꯨꯛꯅꯤ ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 7-ꯒꯤ ꯃꯈꯥꯗ ꯉꯥꯛꯊꯣꯛꯀꯗꯕꯅꯤ꯫
6.9.6 ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚꯁꯤꯡ (drainage reserve). ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚ ꯍꯥꯌꯕꯁꯤ ꯈꯣꯡꯕꯥꯟ ꯌꯥꯑꯣꯅꯥ, ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨ ꯃꯦꯟꯇꯦꯅꯦꯟꯁ ꯇꯧꯕ, ꯄꯥꯛꯊꯣꯛꯍꯟꯕ ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯝꯕꯤ ꯑꯣꯏꯅꯥ ꯁꯤꯖꯤꯟꯅꯕ ꯌꯥꯅꯕ ꯕꯤꯜꯗꯤꯡꯁꯤꯡꯗꯒꯤ ꯂꯥꯞꯅꯥ ꯊꯝꯂꯕ ꯂꯝꯒꯤ ꯁ꯭ꯇ꯭ꯔꯤꯞ ꯑꯃꯅꯤ꯫ ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚ ꯑꯃꯥ ꯃꯈꯥꯒꯤꯁꯤꯡꯗ ꯄꯤꯒꯗꯕꯅꯤ:
- (a) ꯗꯦꯚꯦꯂꯞ ꯅꯠꯔꯒꯥ ꯔꯤꯗꯦꯚꯦꯂꯞ ꯇꯧꯔꯤꯕ ꯂꯦꯑꯥꯎꯠ ꯅꯠꯔꯒꯥ ꯁꯥꯏꯠ ꯑꯃꯒꯤ ꯃꯅꯨꯡꯗ ꯅꯠꯔꯒꯥ ꯃꯅꯥꯛꯇ ꯆꯠꯂꯤꯕ ꯃꯅꯨꯡꯒꯤ ꯄꯥꯛꯄ 1.0 m ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯆꯦꯅꯦꯜ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯅꯥꯛꯇ;
- (b) ꯂꯧꯁꯤꯟꯂꯕ ꯕꯦꯁꯤꯟ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ (Basin Stormwater Master Plan) ꯑꯃꯗ (ꯁꯔꯨꯛ 11) ꯎꯠꯂꯤꯕ ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯆꯦꯅꯦꯜ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯅꯥꯛꯇ, ꯄ꯭ꯂꯥꯟ ꯑꯗꯨꯗ ꯂꯩꯕ ꯃꯊꯡꯒꯤ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯄꯥꯛꯄꯗ; ꯑꯃꯁꯨꯡ
- (c) ꯄꯕ꯭ꯂꯤꯛ ꯕꯣꯗꯤ ꯑꯃꯅꯥ ꯁꯥꯕ ꯃꯅꯨꯡꯒꯤ ꯄꯥꯛꯄ 1.0 m ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯑꯅꯧꯕ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯅꯥꯛꯇ꯫
6.9.7 ꯄꯥꯛꯄ. ꯔꯤꯖꯔꯚ ꯑꯁꯤ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯃꯅꯨꯡꯒꯤ ꯄꯥꯛꯄ W-ꯗꯒꯤ ꯊꯥꯖꯕ, ꯇꯦꯕꯜ 6.9-ꯗ ꯂꯩꯕ ꯄꯥꯛꯄꯗꯒꯤ ꯍꯟꯊꯔꯣꯏꯗꯕꯅꯤ꯫ ꯄꯥꯛꯄ ꯑꯁꯤ ꯂꯩꯔꯤꯕ ꯁꯥꯏꯖ ꯅꯠꯇꯅꯥ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯃꯊꯧ ꯇꯥꯕ ꯁꯥꯏꯖꯗ (ꯄ꯭ꯂꯥꯟ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯤꯗꯃꯛ, ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯗ ꯂꯩꯕ ꯁꯥꯏꯖ) ꯌꯨꯝꯐꯝ ꯑꯣꯏꯏ꯫ ꯀ꯭ꯂꯣꯖ 6.9.4-ꯒꯤ ꯑꯦꯛꯁꯦꯁ ꯁ꯭ꯇ꯭ꯔꯤꯞ ꯑꯁꯤ ꯇꯦꯕꯜ 6.9-ꯗ ꯂꯩꯕ ꯃꯥꯔꯖꯤꯟꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯄꯥꯛꯂꯕ ꯃꯐꯝꯗ, ꯍꯦꯟꯅꯥ ꯄꯥꯛꯄ ꯑꯗꯨꯅꯥ ꯂꯩꯉꯥꯀꯏ꯫
ꯇꯦꯕꯜ 6.9 — ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚꯀꯤ ꯃꯤꯅꯤꯃꯝ ꯄꯥꯛꯄ (PUB Singapore-ꯗꯒꯤ ꯂꯧꯈꯤꯕ)
| ꯈꯣꯡꯕꯥꯟꯒꯤ ꯃꯅꯨꯡꯒꯤ ꯄꯥꯛꯄ, W | ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟ | ꯊꯤꯡꯂꯕ (ꯀꯚꯔ ꯇꯧꯔꯕ) ꯈꯣꯡꯕꯥꯟ |
|---|---|---|
| 1.0 m-ꯗꯒꯤ 1.2 m ꯐꯥꯎꯕ | 3.0 m | W + 0.6 m |
| 1.2 m-ꯗꯒꯤ ꯍꯦꯟꯕ 3.0 m ꯐꯥꯎꯕ | W + 2.6 m | W + 1.6 m |
| 3.0 m-ꯗꯒꯤ ꯍꯦꯟꯕ 4.5 m ꯐꯥꯎꯕ | W + 3.5 m | W + 1.6 m |
| 4.5 m-ꯗꯒꯤ ꯍꯦꯟꯕ 6.0 m ꯐꯥꯎꯕ | W + 4.5 m | W + 3.0 m |
| 6.0 m-ꯗꯒꯤ ꯍꯦꯟꯕ 9.0 m ꯐꯥꯎꯕ | W + 6.0 m | W + 3.0 m |
| 9.0 m-ꯗꯒꯤ ꯍꯦꯟꯕ 25.0 m ꯐꯥꯎꯕ | W + 7.5 m | W + 3.0 m |
| 25.0 m-ꯗꯒꯤ ꯍꯦꯟꯕ | W + 12.0 m | W + 3.0 m |
ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯤꯗꯃꯛ, ꯃꯥꯔꯖꯤꯟꯒꯤ ꯍꯦꯟꯅꯥ ꯆꯥꯎꯕ ꯁꯔꯨꯛ ꯑꯗꯨ ꯃꯦꯟꯇꯦꯅꯦꯟꯁꯀꯤ ꯑꯦꯛꯁꯦꯁꯀꯤꯗꯃꯛ ꯁꯤꯖꯤꯟꯅꯕ ꯃꯥꯏꯀꯩꯗ ꯂꯩꯒꯗꯕꯅꯤ꯫
6.9.8 ꯁꯤꯖꯤꯟꯅꯕ ꯑꯃꯁꯨꯡ ꯉꯥꯛꯊꯣꯀꯄ.
- (a) ꯔꯤꯖꯔꯚ ꯑꯁꯤ ꯂꯦꯑꯥꯎꯠ ꯅꯠꯔꯒꯥ ꯁꯥꯏꯠ ꯄ꯭ꯂꯥꯟꯗ ꯇꯣꯉꯥꯟꯕ ꯄ꯭ꯂꯣꯠ ꯑꯃꯥ ꯑꯣꯏꯅꯥ ꯎꯠꯀꯗꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯂꯝꯕꯤꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯣꯄꯟ ꯁ꯭ꯄꯦꯁꯀꯤ ꯔꯤꯖꯔꯚꯦꯁꯟꯁꯤꯡꯒꯨꯝꯅꯥ ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯗ ꯃꯃꯜ ꯂꯧꯗꯅꯥ ꯍꯣꯡꯗꯣꯛꯀꯗꯕꯅꯤ꯫ ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨ ꯋꯥꯇꯔ ꯔꯤꯁꯣꯔꯁꯦꯁ ꯗꯤꯄꯥꯔꯠꯃꯦꯟꯠꯀꯤ (Water Resources Department) ꯆꯦꯅꯦꯜ ꯑꯃꯥ ꯑꯣꯏꯔꯕ ꯃꯐꯝꯗ, ꯔꯤꯖꯔꯚ ꯑꯁꯤ ꯋꯥꯇꯔ ꯔꯤꯁꯣꯔꯁꯦꯁ ꯗꯤꯄꯥꯔꯠꯃꯦꯟꯠꯇ ꯍꯣꯡꯗꯣꯀꯏ꯫
- (b) ꯔꯤꯖꯔꯚ ꯑꯁꯤꯗ ꯕꯤꯜꯗꯤꯡ, ꯀꯝꯄꯥꯎꯟꯗ ꯋꯣꯜ, ꯐꯦꯟꯁ, ꯔꯦꯝꯞ, ꯈꯣꯡꯊꯥꯡ, ꯐꯤꯜ ꯅꯠꯔꯒꯥ ꯑꯇꯣꯞꯄ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔ ꯑꯃꯠꯇꯥ ꯁꯥꯔꯣꯏꯗꯕꯅꯤ꯫ ꯀꯝꯄꯥꯎꯟꯗ ꯋꯣꯜꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯉꯃꯈꯩꯒꯤ ꯐꯦꯟꯁꯁꯤꯡ ꯑꯁꯤ ꯃꯁꯤꯒꯤ ꯃꯄꯥꯟꯗ ꯂꯩꯒꯗꯕꯅꯤ꯫
- (c) ꯔꯤꯖꯔꯚꯇ ꯂꯩꯕ ꯑꯦꯛꯁꯦꯁ ꯁ꯭ꯇ꯭ꯔꯤꯞ ꯑꯁꯤ ꯐꯥꯔꯕ ꯑꯃꯁꯨꯡ ꯂꯦꯞꯇꯅꯥ ꯂꯩꯕ ꯑꯣꯏꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯕꯤ ꯑꯃꯗ ꯁꯝꯃꯤꯟꯅꯒꯗꯕꯅꯤ꯫ ꯃꯦꯟꯇꯦꯅꯦꯟꯁꯀꯤ ꯒꯥꯔꯤꯁꯤꯡ ꯅꯠꯇꯕ ꯒꯥꯔꯤꯁꯤꯡ ꯆꯡꯍꯟꯗꯅꯕ ꯆꯡꯐꯝꯁꯤꯡꯗ ꯕꯣꯂꯥꯔꯗꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯄꯣꯁ꯭ꯠ ꯑꯃꯁꯨꯡ ꯆꯦꯟꯁꯤꯡ ꯁꯤꯖꯤꯟꯅꯕ ꯌꯥꯏ꯫
- (d) ꯔꯤꯖꯔꯚ ꯑꯁꯤ ꯐꯦꯟꯁ ꯇꯧꯗꯕ ꯃꯐꯝꯗ, ꯃꯁꯤꯒꯤ ꯃꯄꯥꯟ ꯑꯁꯤ 50 m-ꯗꯒꯤ ꯍꯦꯟꯗꯕ ꯂꯥꯞ ꯊꯥꯛꯇ ꯀꯟꯀ꯭ꯔꯤꯠ ꯃꯥꯔꯀꯔꯁꯤꯡꯅꯥ ꯈꯥꯌꯗꯣꯛꯀꯗꯕꯅꯤ꯫
- (e) ꯁꯔꯚꯤꯁꯁꯤꯡ ꯑꯁꯤ ꯏꯟꯚꯔꯠꯀꯤ ꯃꯈꯥꯗ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 1.0 m-ꯒꯤ ꯂꯥꯞ ꯂꯩꯅꯥ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯃꯈꯥꯗꯒꯤ, ꯅꯠꯔꯒꯥ ꯑꯦꯞꯔꯨꯚ ꯇꯧꯔꯕ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔ ꯑꯃꯗ ꯃꯁꯤꯒꯤ ꯃꯊꯛꯇꯒꯤ ꯀ꯭ꯔꯣꯁ ꯇꯧꯒꯗꯕꯅꯤ꯫ ꯁꯔꯚꯤꯁꯁꯤꯡ ꯑꯁꯤ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯦꯛꯁꯟꯒꯤ ꯃꯅꯨꯡꯗ ꯔꯤꯖꯔꯚꯀꯤ ꯃꯅꯥꯛꯇ ꯆꯠꯂꯣꯏꯗꯕꯅꯤ꯫
- (f) ꯔꯤꯖꯔꯚꯀꯤ ꯃꯄꯥꯟꯗꯒꯤ 2 m-ꯒꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯕ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔ ꯑꯃꯥ ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨ ꯃꯁꯤꯒꯤ ꯏꯟꯚꯔꯠꯀꯤ ꯃꯈꯥꯗ 1.0 m ꯐꯥꯎꯕ ꯇꯨꯝꯂꯕꯁꯨ ꯆꯦꯠꯅꯥ ꯂꯩꯕ ꯃꯑꯣꯡꯗ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ꯫ ꯗꯤꯖꯥꯏꯟ ꯑꯁꯤ ꯀ꯭ꯕꯥꯂꯤꯐꯥꯏ ꯑꯣꯏꯕ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔꯦꯜ ꯏꯟꯖꯤꯅꯤꯌꯔ ꯑꯃꯅꯥ ꯁꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ꯫
- (g) ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯒꯤ ꯔꯨꯜꯁꯤꯡꯅꯥ ꯌꯥꯍꯜꯂꯕ ꯃꯐꯝꯗ ꯈꯛꯇꯗ ꯔꯤꯖꯔꯚ ꯑꯁꯤ ꯁꯥꯏꯠꯀꯤ ꯑꯣꯄꯟ ꯁ꯭ꯄꯦꯁꯀꯤ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡꯗ ꯃꯁꯤꯡ ꯊꯤꯏ; ꯃꯁꯤꯅꯥ ꯁꯔꯨꯛ 7-ꯅꯥ ꯃꯊꯧ ꯇꯥꯕ ꯁꯦꯠꯕꯦꯛ (setback) ꯑꯃꯠꯇꯥ ꯍꯟꯊꯍꯟꯗꯦ꯫
ꯃꯃꯤ 6.4 — ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯤ ꯃꯅꯥꯛꯇ ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚ: ꯇꯦꯕꯜ 6.9-ꯗꯒꯤ ꯔꯤꯖꯔꯚꯀꯤ ꯄꯥꯛꯄ, ꯁ꯭ꯇ꯭ꯔꯛꯆꯔ ꯌꯥꯗꯕ ꯖꯣꯟ, ꯃꯦꯟꯇꯦꯅꯦꯟꯁꯀꯤ ꯃꯥꯏꯀꯩꯗ ꯑꯦꯛꯁꯦꯁ ꯁ꯭ꯇ꯭ꯔꯤꯞ, ꯏꯟꯚꯔꯠꯀꯤ ꯃꯈꯥꯗ 1.0 m-ꯒꯤ ꯁꯔꯚꯤꯁ ꯀ꯭ꯂꯤꯌꯔꯦꯟꯁ ꯑꯃꯁꯨꯡ 2 m-ꯒꯤ ꯁ꯭ꯇꯦꯕꯤꯂꯤꯇꯤ-ꯆꯦꯛ ꯖꯣꯟ (ꯀ꯭ꯂꯣꯖ 6.9.6-ꯗꯒꯤ 6.9.8 ꯐꯥꯎꯕ)꯫ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ ꯑꯅꯧꯅꯥ ꯁꯦꯝꯕ ꯗ꯭ꯔꯣꯏꯡ, PUB Singapore, Code of Practice on Surface Water Drainage (7th ed., with Addendum No. 3, 2025), clauses 5.1, 5.3, 9.6 and 9.7 and Appendix 1-ꯗꯒꯤ ꯍꯣꯡꯗꯣꯛꯂꯒꯥ ꯂꯧꯈꯤꯕ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚꯁꯤꯡ ꯑꯁꯤ ꯁꯤꯡꯒꯥꯄꯨꯔ ꯃꯇꯨꯡ ꯏꯟꯅꯔꯤ, ꯃꯐꯝ ꯑꯗꯨꯗ "ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚ ꯑꯃꯒꯤ ꯄꯥꯛꯄ ꯑꯁꯤ ꯃꯊꯧ ꯇꯥꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯥꯏꯖꯗ ꯌꯨꯝꯐꯝ ꯑꯣꯏꯏ" ("the width of a drainage reserve is based on the required drain size") ꯑꯃꯁꯨꯡ ꯔꯤꯖꯔꯚ ꯑꯁꯤ "ꯑꯊꯤꯡꯕ ꯄꯨꯝꯅꯃꯛꯇꯒꯤ ꯂꯥꯞꯅꯥ ꯊꯝꯂꯕ" ("kept free of all encumbrances") ꯇꯣꯉꯥꯟꯕ ꯄ꯭ꯂꯣꯠ ꯑꯃꯥ ꯑꯣꯏꯅꯥ ꯊꯝꯃꯤ (PUB Code of Practice on Surface Water Drainage, 7th ed. with Addendum No. 3, 2025, cl. 1.1)꯫ ꯇꯦꯕꯜ 6.9-ꯅꯥ PUB-ꯒꯤ Appendix 1-ꯒꯤ ꯄꯥꯛꯄꯁꯤꯡ ꯑꯃꯨꯛ ꯍꯟꯅꯥ ꯄꯤꯔꯤ꯫ ꯀ꯭ꯂꯣꯖ 6.9.8(b)-ꯗꯒꯤ (f) ꯐꯥꯎꯕ ꯑꯁꯤ PUB-ꯒꯤ clauses 5.1 (ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚ ꯑꯃꯒꯤ ꯃꯅꯨꯡꯗ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔ ꯑꯃꯠꯇꯥ ꯌꯥꯔꯣꯏ), 5.3 ꯑꯃꯁꯨꯡ 5.3.1 (ꯏꯟꯚꯔꯠꯀꯤ ꯃꯈꯥꯗ 1.0 m ꯇꯨꯝꯕꯒꯤꯗꯃꯛ ꯁ꯭ꯇꯦꯕꯤꯂꯤꯇꯤ; ꯔꯤꯖꯔꯚꯗꯒꯤ 2 m-ꯒꯤ ꯃꯅꯨꯡꯗ ꯏꯟꯖꯤꯅꯤꯌꯔꯒꯤ ꯀꯦꯜꯀꯨꯂꯦꯁꯟꯁꯤꯡ), 9.6 (ꯕꯣꯂꯥꯔꯗꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯄꯣꯁ꯭ꯠ ꯑꯃꯁꯨꯡ ꯆꯦꯟꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ ꯐꯥꯔꯕ, ꯂꯦꯞꯇꯅꯥ ꯂꯩꯕ ꯑꯦꯛꯁꯦꯁ) ꯑꯃꯁꯨꯡ 9.7 (ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯍꯦꯟꯕꯗ 50 m-ꯗ ꯃꯥꯔꯀꯔꯁꯤꯡ) ꯃꯇꯨꯡ ꯏꯟꯅꯔꯤ꯫ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯤ ꯃꯈꯥꯗꯒꯤ ꯀ꯭ꯔꯣꯁ ꯇꯧꯕ ꯁꯔꯚꯤꯁꯁꯤꯡꯒꯤꯗꯃꯛ 1.0 m-ꯒꯤ ꯀ꯭ꯂꯤꯌꯔꯦꯟꯁ ꯑꯁꯤ PUB-ꯒꯤ ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ-ꯄ꯭ꯂꯥꯟꯒꯤ ꯒꯥꯏꯗꯦꯟꯁꯇꯒꯤꯅꯤ꯫ ꯃꯅꯤꯄꯨꯔꯗ, ꯕꯤꯜꯗꯤꯡꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯀꯝꯄꯥꯎꯟꯗ ꯋꯣꯜꯁꯤꯡ ꯑꯁꯤ ꯌꯥꯝꯅꯥ ꯃꯇꯝꯗ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯤ ꯃꯄꯥꯟ ꯐꯥꯎꯕ ꯁꯥꯏ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯃꯁꯤ ꯄꯥꯛꯊꯣꯛꯍꯟꯕ ꯅꯠꯔꯒꯥ ꯃꯦꯁꯤꯅꯅꯥ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯛꯄ ꯌꯥꯗꯦ꯫ ꯄ꯭ꯂꯣꯠ ꯑꯃꯥ ꯗꯦꯚꯦꯂꯞ ꯅꯠꯔꯒꯥ ꯔꯤꯗꯦꯚꯦꯂꯞ ꯇꯧꯔꯀꯄ ꯃꯇꯝꯗ ꯂꯝ ꯔꯤꯖꯔꯚ ꯇꯧꯕ ꯑꯁꯤ ꯃꯗꯨ ꯉꯥꯛꯊꯣꯛꯅꯕ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯃꯃꯜ ꯌꯥꯝꯗꯕ ꯃꯇꯝꯅꯤ, ꯃꯔꯝꯗꯤ ꯃꯇꯨꯡꯗ ꯄꯥꯛꯊꯣꯛꯍꯟꯅꯕ ꯂꯦꯟꯗ ꯑꯦꯀ꯭ꯋꯤꯖꯤꯁꯟ (land acquisition) ꯃꯊꯧ ꯇꯥꯏ꯫ ꯄꯥꯛꯄ ꯑꯁꯤ ꯃꯥꯁ꯭ꯇꯔ-ꯄ꯭ꯂꯥꯟꯒꯤ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯥꯏꯖꯗ ꯌꯨꯝꯐꯝ ꯑꯣꯏꯕꯅꯥ (6.9.6(b)) ꯃꯊꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯅꯥ ꯃꯊꯧ ꯇꯥꯒꯗꯕ ꯂꯝ ꯑꯗꯨ ꯉꯥꯛꯊꯣꯀꯏ꯫ ꯃꯅꯤꯄꯨꯔꯗ ꯃꯁꯤꯒꯤ ꯃꯃꯤꯡ ꯂꯧꯔꯕ ꯇꯝꯄꯥꯛꯀꯤ ꯇꯨꯔꯦꯜꯁꯤꯡꯒꯤ ꯃꯅꯥꯛꯇ ꯑꯥꯏꯟꯒꯤ ꯕꯤꯜꯗꯤꯡ ꯕꯐꯔ (buffer) ꯑꯃꯥ ꯂꯩ, ꯑꯗꯨꯕꯨ ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜ ꯑꯃꯒꯤ ꯃꯅꯥꯛꯇ ꯔꯤꯖꯔꯚꯀꯤ ꯄꯥꯛꯄ ꯑꯃꯠꯇꯥ ꯂꯩꯇꯦ, ꯑꯃꯁꯨꯡ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯐ꯭ꯂꯗꯄ꯭ꯂꯦꯟ ꯖꯣꯟ (floodplain zone) ꯑꯃꯠꯇꯥ ꯂꯩꯇꯦ꯫ ꯕꯐꯔ ꯑꯁꯤ ꯃꯣꯗꯦꯜꯒꯤ ꯕꯥꯏ-ꯂꯣ 93-ꯒꯤꯅꯤ [TBC: ꯂꯣꯀꯜ ꯕꯣꯗꯤꯅꯥ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯕꯥꯏ-ꯂꯣꯖꯇ ꯅꯝꯕꯔ ꯑꯃꯁꯨꯡ ꯇꯦꯛꯁꯇ ꯆꯦꯛ ꯇꯧꯒꯗꯕꯅꯤ]: "ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯈꯨꯗꯣꯡꯆꯥꯕꯗ ꯃꯤꯑꯣꯏꯕ ꯐꯥꯑꯣꯕ ꯍꯟꯊꯍꯟꯅꯕ ꯑꯃꯁꯨꯡ ꯃꯍꯧꯁꯥꯒꯤ ꯏꯀꯣꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯒꯤ ꯃꯍꯧꯁꯥꯒꯤ ꯃꯑꯣꯡ ꯉꯥꯛꯊꯣꯛꯅꯕ ꯗꯦꯖꯤꯒꯅꯦꯠ ꯇꯧꯔꯕ ꯕꯐꯔ ꯖꯣꯟꯒꯤ ꯃꯅꯨꯡꯗ ꯑꯅꯧꯕ ꯀꯟꯁ꯭ꯇ꯭ꯔꯛꯁꯟ ꯑꯃꯠꯇꯥ ꯌꯥꯍꯟꯂꯣꯏꯗꯕꯅꯤ" ("Prohibit any new construction within the designated buffer zone to minimize human exposure to flood risk and preserve the natural integrity of natural ecosystems"), ꯑꯣꯏ ꯑꯃꯁꯨꯡ ꯌꯦꯠ ꯂꯩꯔꯥꯏ ꯑꯅꯤꯃꯛꯀꯤꯗꯃꯛ ꯃꯥꯟꯅꯕ ꯇꯨꯔꯦꯜꯁꯤꯡꯒꯤ ꯇꯦꯕꯜ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ: ꯀꯣꯏꯔꯦꯡꯒꯩꯗꯒꯤ (Koirengei) ꯂꯤꯂꯣꯡ ꯐꯥꯎꯕ ꯏꯝꯐꯥꯜ ꯇꯨꯔꯦꯜ 55 m, ꯂꯤꯂꯣꯡꯗꯒꯤ ꯁꯦꯛꯃꯥꯏꯖꯤꯟ ꯐꯥꯎꯕ 60 m ꯑꯃꯁꯨꯡ ꯁꯦꯛꯃꯥꯏꯖꯤꯟꯗꯒꯤ ꯏꯊꯥꯏ ꯐꯥꯎꯕ 62 m; ꯍꯩꯔꯣꯛ ꯊꯣꯡꯗꯒꯤ ꯈꯥꯔꯨꯡꯄꯥꯠ ꯐꯥꯎꯕ ꯋꯥꯡꯖꯤꯡ ꯇꯨꯔꯦꯜ 31 m; ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜ ꯑꯦꯔꯤꯌꯥꯒꯤ ꯃꯅꯨꯡꯗ ꯅꯝꯕꯨꯜ ꯇꯨꯔꯦꯜ 30 m; ꯁꯋꯣꯝꯕꯨꯡꯗꯒꯤ (Sawombung) ꯂꯤꯂꯣꯡ ꯐꯥꯎꯕ ꯏꯔꯤꯜ ꯇꯨꯔꯦꯜ (Iril) 50 m; ꯌꯥꯏꯔꯤꯄꯣꯛꯇꯒꯤ ꯏꯔꯣꯡ ꯏꯆꯤꯜ (Irong Ichil) ꯐꯥꯎꯕ ꯊꯧꯕꯥꯜ ꯇꯨꯔꯦꯜ 48 m; ꯄꯥꯂꯦꯜ ꯊꯣꯡꯗꯒꯤ (Pallel bridge) ꯁꯦꯛꯃꯥꯏꯖꯤꯟꯗ ꯏꯝꯐꯥꯜ ꯇꯨꯔꯦꯜꯒꯥ ꯁꯝꯅꯕ ꯃꯐꯝ ꯐꯥꯎꯕ ꯁꯦꯛꯃꯥꯏ ꯇꯨꯔꯦꯜ 35 m; ꯑꯃꯁꯨꯡ ꯆꯔꯥꯡꯄꯥꯠꯇꯒꯤ (Charangpat) ꯏꯀꯣꯞ ꯄꯥꯠ ꯐꯥꯎꯕ ꯑꯔꯣꯡ ꯇꯨꯔꯦꯜ (Arong) 30 m, ꯃꯈꯣꯌ ꯈꯨꯗꯤꯡꯃꯛ "ꯇꯨꯔꯦꯜꯒꯤ ꯃꯌꯥꯏꯗꯒꯤ (mid-stream) ꯅꯠꯔꯒꯥ ꯄꯟꯒꯤ ꯃꯄꯥꯟꯒꯤ ꯇꯣꯗꯒꯤ 6 m, ꯇꯨꯔꯦꯜꯒꯤ ꯃꯌꯥꯏꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯂꯥꯞꯄ ꯑꯗꯨ" ("from mid-stream or 6 m from outer toe of bund, whichever is further from mid-stream"); ꯑꯃꯁꯨꯡ ꯔꯤꯆ ꯃꯇꯨꯡ ꯏꯟꯅ ꯃꯦꯔꯥꯈꯣꯡ (Merakhong) 22.5 m, 24.2 m ꯑꯃꯁꯨꯡ 28 m, ꯀꯣꯡꯕ ꯇꯨꯔꯦꯜ (Kongba) 35 m ꯑꯃꯁꯨꯡ ꯅꯝꯕꯣꯜ ꯇꯨꯔꯦꯜ 25 m, ꯇꯨꯔꯦꯜꯒꯤ ꯃꯌꯥꯏꯗꯒꯤ ꯈꯛꯇꯃꯛ꯫ IMC (3rd Amendment) 2024-ꯒꯤ ꯗ꯭ꯔꯥꯐꯠꯅꯥ ꯇꯦꯕꯜ ꯑꯗꯨ ꯑꯃꯨꯛ ꯍꯟꯅꯥ ꯄꯤꯔꯤ (93.1)꯫ ꯕꯥꯏ-ꯂꯣ ꯑꯁꯤꯅꯥ "ꯐ꯭ꯂꯗ ꯄ꯭ꯂꯦꯟ ꯖꯣꯅꯤꯡ ꯑꯦꯛꯠ, 1978-ꯒꯤ ꯃꯈꯥꯗ ꯁꯦꯝꯈꯤꯕ ꯐ꯭ꯂꯗ ꯖꯣꯅꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯒꯤ ꯃꯃꯥꯡꯒꯤ ꯑꯌꯥꯕ ꯂꯧꯗꯅꯥ ꯀꯅꯥꯒꯨꯝꯕ ꯑꯃꯠꯇꯅꯥ ꯊꯤꯡꯂꯕ ꯑꯦꯔꯤꯌꯥ ꯅꯠꯔꯒꯥ ꯔꯦꯁ꯭ꯇ꯭ꯔꯤꯛꯇ ꯇꯧꯔꯕ ꯑꯦꯔꯤꯌꯥꯒꯤ ꯃꯅꯨꯡꯗ ꯊꯕꯛ ꯑꯃꯠꯇꯥ ꯇꯧꯔꯣꯏꯗꯕꯅꯤ" ("No person shall undertake any activity within the prohibited area or restricted area except with the previous permission of the Flood Zoning Authority constituted under the Flood Plain Zoning Act, 1978") ꯍꯥꯌꯅꯥ ꯍꯥꯄꯆꯤꯜꯂꯤ, ꯑꯗꯨꯕꯨ ꯐ꯭ꯂꯗ ꯖꯣꯅꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤ (Flood Zoning Authority) ꯑꯃꯠꯇꯥ ꯑꯃꯁꯨꯡ ꯊꯤꯡꯂꯕ ꯅꯠꯔꯒꯥ ꯔꯦꯁ꯭ꯇ꯭ꯔꯤꯛꯇ ꯇꯧꯔꯕ ꯑꯦꯔꯤꯌꯥ ꯑꯃꯠꯇꯥ ꯁꯦꯝꯈꯤꯕ ꯅꯠꯔꯒꯥ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯈꯤꯕ ꯐꯡꯈꯤꯗꯦ (NEER-ꯒꯤ ꯄꯥꯕ), ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯖꯣꯟꯁꯤꯡ ꯈꯥꯌꯗꯣꯀꯄ ꯑꯁꯤ "ꯍꯧꯖꯤꯛꯁꯨ ꯇꯧꯗ꯭ꯔꯤ" ("is yet to be done") (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ, ꯖꯨꯟ 2026)꯫ ꯕꯐꯔꯁꯤꯡ ꯑꯁꯤ ꯇꯨꯔꯦꯜꯒꯤ ꯃꯌꯥꯏꯗꯒꯤ ꯊꯥꯖꯏ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ 40 m ꯄꯥꯛꯄ ꯔꯤꯆ ꯑꯃꯗ 30 m-ꯒꯤ ꯕꯐꯔ ꯑꯃꯅꯥ ꯂꯩꯔꯥꯏꯗꯒꯤ 10 m ꯈꯛꯇꯃꯛ ꯊꯃꯏ (NEER-ꯒꯤ ꯄꯥꯕ)꯫ "ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯜ ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯂꯝ ꯑꯃꯠꯇꯒꯤ ꯃꯊꯛꯇ" ("over any municipal drain or land") ꯕꯤꯜꯗꯤꯡ ꯑꯃꯠꯇꯥ ꯊꯝꯕ ꯌꯥꯗꯦ (ꯕꯥꯏ-ꯂꯣ 16)꯫ ꯕꯥꯏ-ꯂꯣꯖꯇ ꯄꯥꯠ ꯅꯠꯔꯒꯥ ꯄꯨꯈ꯭ꯔꯤ ꯑꯃꯒꯤ ꯑꯀꯣꯌꯕꯗ ꯕꯐꯔ ꯑꯃꯠꯇꯥ ꯂꯩꯇꯦ (NEER-ꯒꯤ ꯄꯥꯕ)꯫ ꯂꯣꯛꯇꯥꯛꯀꯤ ꯑꯀꯣꯌꯕꯗ, 70.30 km²-ꯒꯤ ꯀꯣꯔ ꯖꯣꯟ ꯑꯁꯤ "ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯌꯥꯗꯕ ꯖꯣꯟ ꯅꯠꯔꯒꯥ ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯉꯥꯛꯊꯣꯛꯂꯕ ꯖꯣꯟ" ("No-Development Zone or Totally Protected Zone") ꯑꯃꯅꯤ, ꯕꯐꯔ ꯖꯣꯟꯅꯥ "ꯂꯝ ꯔꯤꯛꯂꯦꯃꯦꯁꯟ, ꯄꯟ ꯁꯥꯕ ꯅꯠꯔꯒꯥ ꯏꯔꯝꯒꯤ ꯃꯍꯧꯁꯥꯒꯤ ꯂꯝꯕꯤ ꯁꯣꯛꯍꯟꯕ" ("Land reclamation, bunding or disturbing the natural course of drainages") ꯊꯤꯡꯏ (ꯃꯅꯤꯄꯨꯔ ꯂꯣꯛꯇꯥꯛ ꯂꯦꯛ (ꯄ꯭ꯔꯣꯇꯦꯛꯁꯟ) ꯑꯦꯛꯠ, 2006, ꯁꯦꯛꯁꯟ 3 ꯑꯃꯁꯨꯡ 19(vi)), ꯑꯃꯁꯨꯡ ꯍꯥꯏ ꯀꯣꯔꯠꯀꯤ ꯁ꯭ꯄꯦꯁꯤꯌꯦꯜ ꯕꯦꯟꯆꯅꯥ 17 ꯖꯨꯂꯥꯏ 2019-ꯗ ꯑꯃꯁꯨꯡ ꯑꯃꯨꯛ ꯍꯟꯅꯥ 25 ꯐꯦꯕ꯭ꯔꯨꯋꯥꯔꯤ 2022-ꯗ ꯂꯣꯛꯇꯥꯛꯀꯤ ꯃꯅꯨꯡꯗ ꯅꯠꯔꯒꯥ ꯑꯀꯣꯌꯕꯗ "ꯀꯣꯔꯠꯀꯤ ꯑꯌꯥꯕ ꯂꯧꯗꯅꯥ" ("without the Court's leave") ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯑꯃꯠꯇꯥ ꯇꯧꯔꯣꯏꯗꯕꯅꯤ ꯍꯥꯌꯅꯥ ꯑꯣꯔꯗꯔ ꯄꯤꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ; ꯀꯦꯁ ꯅꯝꯕꯔ ꯐꯡꯈꯤꯗꯦ [TBC])꯫ ꯁ꯭ꯇꯦꯠ ꯋꯦꯠꯂꯦꯟꯗꯁ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯌꯥꯔꯥꯜ, ꯎꯇ꯭ꯔꯥ ꯑꯃꯁꯨꯡ ꯋꯥꯏꯊꯧ–ꯐꯨꯝꯅꯣꯝ ꯄꯥꯠꯁꯤꯡꯒꯤ (Yaral, Utra, Waithou–Phumnom) ꯗ꯭ꯔꯥꯐꯠ ꯅꯣꯇꯤꯐꯤꯀꯦꯁꯟꯁꯤꯡ ꯐꯣꯡꯗꯣꯛꯈ꯭ꯔꯦ (DoECC, 2025-26), ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌ ꯑꯔꯣꯏꯕ ꯑꯣꯏꯗ꯭ꯔꯤꯐꯥꯎꯕ ꯋꯦꯠꯂꯦꯟꯗꯁ ꯔꯨꯂꯁ, 2017-ꯒꯤ ꯊꯤꯡꯕ ꯑꯃꯠꯇꯥ ꯃꯈꯣꯌꯗ ꯆꯠꯅꯗꯦ (NEER-ꯒꯤ ꯄꯥꯕ)꯫ ꯌꯨꯅꯤꯐꯥꯏꯗ ꯖꯣꯅꯤꯡ ꯕꯥꯏ-ꯂꯣꯖ, 2026-ꯗ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ ꯑꯦꯔꯤꯌꯥ ꯈꯨꯗꯤꯡꯃꯛꯇ "ꯄꯣꯟꯗ, ꯈꯣꯡꯕꯥꯟ, ꯇꯨꯔꯦꯜꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯀꯦꯅꯦꯜꯁꯤꯡ" ("Pond, Drain, Rivers and Canals") ꯍꯥꯌꯕ ꯌꯨꯖ ꯖꯣꯟ ꯑꯃꯥ ꯂꯩ, ꯃꯐꯝ ꯑꯗꯨꯗ ꯔꯤꯖꯔꯚ ꯑꯃꯥ ꯎꯠꯄ ꯌꯥꯏ꯫ ꯃꯈꯣꯌ ꯑꯁꯤꯒꯤ ꯃꯔꯛꯇ ꯑꯃꯠꯇꯅꯥ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜ ꯅꯠꯔꯒꯥ ꯁꯍꯔꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯤ ꯃꯅꯥꯛꯇ ꯔꯤꯖꯔꯚꯀꯤ ꯄꯥꯛꯄ ꯄꯤꯗꯦ꯫ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ, ꯃꯁꯥꯒꯤ ꯄ꯭ꯔꯄꯣꯖꯦꯜ ꯑꯣꯏꯅꯥ ꯑꯃꯁꯨꯡ ꯔꯨꯜꯁꯤꯡꯒꯤ ꯑꯔꯊ ꯑꯣꯏꯅꯥ ꯅꯠꯇꯅꯥ, ꯆꯦꯅꯦꯜ ꯑꯃꯒꯤ ꯂꯩꯔꯥꯏ ꯍꯥꯌꯕꯁꯤ ꯃꯁꯤꯒꯤ ꯂꯩꯔꯥꯏꯒꯤ ꯃꯊꯛꯅꯤ, ꯑꯃꯁꯨꯡ ꯄꯟ ꯂꯩꯕ ꯔꯤꯆ ꯑꯃꯗ ꯄꯟꯒꯤ ꯂꯝꯒꯤ ꯃꯥꯏꯀꯩꯒꯤ ꯇꯣꯅꯤ; ꯄꯥꯠ ꯅꯠꯔꯒꯥ ꯄꯨꯈ꯭ꯔꯤ ꯑꯃꯒꯤ ꯃꯄꯥꯟ ꯍꯥꯌꯕꯁꯤ ꯃꯁꯤꯒꯤ ꯃꯇꯝꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ ꯋꯥꯡꯕ ꯂꯦꯚꯦꯜꯗ ꯂꯩꯕ ꯉꯃꯈꯩꯅꯤ (ꯁꯔꯨꯛ 7); ꯑꯃꯁꯨꯡ 8 ha ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯏꯔꯝ ꯄꯤꯕ ꯈꯣꯡ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯃꯍꯧꯁꯥꯒꯤ ꯆꯦꯅꯦꯜ ꯈꯨꯗꯤꯡꯃꯛ, ꯀꯅꯥꯅꯥ ꯃꯦꯟꯇꯦꯅꯦꯟꯁ ꯇꯧꯔꯕꯁꯨ ꯑꯃꯁꯨꯡ ꯂꯥꯏꯟ ꯇꯧꯔꯕꯁꯨ, ꯄꯥꯏꯞ ꯇꯧꯔꯕꯁꯨ ꯅꯠꯔꯒꯥ ꯀꯚꯔ ꯇꯧꯔꯕꯁꯨ, ꯀ꯭ꯂꯣꯖ 7.4.1(b)-ꯒꯤ ꯃꯈꯥꯗ ꯃꯍꯧꯁꯥꯒꯤ ꯆꯦꯅꯦꯜ ꯑꯃꯅꯤ (ꯄꯨꯝꯅꯃꯛ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕ)꯫ ꯃꯔꯝ ꯑꯁꯤꯅꯥ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯔꯤꯖꯔꯚ ꯑꯁꯤꯗ ꯄꯥꯛꯄ ꯑꯃꯥ ꯄꯤꯔꯤ, ꯃꯁꯥꯒꯤ ꯄ꯭ꯔꯄꯣꯖꯦꯜ ꯑꯣꯏꯅꯥ ꯑꯃꯁꯨꯡ ꯑꯥꯏꯟꯒꯤ ꯄꯥꯛꯄ ꯑꯣꯏꯅꯥ ꯅꯠꯇꯅꯥ: ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯀꯣꯔꯤꯗꯣꯔ (hydraulic corridor) ꯑꯃꯥ, ꯃꯁꯤꯗ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣ ꯄꯨꯅꯕ ꯃꯊꯧ ꯇꯥꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯥꯏꯖꯗ ꯌꯨꯝꯐꯝ ꯑꯣꯏꯕ, ꯆꯤꯡꯁꯤꯡꯗ ꯀ꯭ꯂꯣꯖ 6.3.6(g)-ꯒꯤ ꯕꯜꯀꯤꯡ ꯐꯦꯛꯇꯔꯒꯥ ꯂꯣꯌꯅꯅ (ꯀ꯭ꯂꯣꯖ 6.9.7), ꯇꯦꯕꯜ 6.9-ꯒꯤ ꯔꯤꯖꯔꯚ, ꯑꯦꯛꯁꯦꯁꯀꯤ ꯂꯩꯔꯥꯏꯗ ꯀ꯭ꯂꯣꯖ 6.9.4-ꯒꯤ ꯑꯦꯛꯁꯦꯁ ꯁ꯭ꯇ꯭ꯔꯤꯞ, ꯑꯃꯁꯨꯡ, 8 ha ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯦꯟꯕ ꯏꯔꯝ ꯄꯤꯕ ꯃꯍꯧꯁꯥꯒꯤ ꯆꯦꯅꯦꯜ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯅꯥꯛꯇ ꯑꯃꯁꯨꯡ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯌꯥꯎꯕ ꯄꯥꯠ ꯑꯃꯁꯨꯡ ꯄꯨꯈ꯭ꯔꯤ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯑꯀꯣꯌꯕꯗ, ꯀ꯭ꯂꯣꯖ 7.4-ꯒꯤ ꯁꯦꯠꯕꯦꯛꯁꯤꯡ, ꯂꯩꯔꯥꯏꯒꯤ ꯃꯊꯛꯇꯒꯤ, ꯄꯟ ꯂꯩꯕ ꯔꯤꯆ ꯑꯃꯗ ꯄꯟꯒꯤ ꯂꯝꯒꯤ ꯃꯥꯏꯀꯩꯒꯤ ꯇꯣꯗꯒꯤ, ꯅꯠꯔꯒꯥ ꯄꯥꯠ ꯅꯠꯔꯒꯥ ꯄꯨꯈ꯭ꯔꯤ ꯑꯃꯒꯤ ꯉꯃꯈꯩꯗꯒꯤ 15 m-ꯗꯒꯤ ꯍꯟꯊꯗꯕ ꯖꯣꯟ 1 ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯁꯟꯗꯣꯛꯄ ꯑꯃꯁꯨꯡ 10 m ꯐꯥꯎꯕ ꯖꯣꯟ 2 ꯌꯥꯑꯣꯅꯥ, ꯏꯁꯤꯡꯗꯒꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯂꯥꯞꯅꯥ ꯌꯧꯕ ꯂꯥꯏꯟ ꯑꯗꯨꯅꯥ ꯂꯩꯉꯥꯀꯄ; ꯕꯥꯏ-ꯂꯣꯒꯤ ꯇꯦꯕꯜ, ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ, ꯂꯣꯛꯇꯥꯛ ꯑꯦꯛꯠ, ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯋꯦꯠꯂꯦꯟꯗ ꯑꯃꯥ ꯅꯠꯔꯒꯥ ꯀꯣꯔꯠ ꯑꯃꯅꯥ ꯍꯦꯟꯅꯥ ꯄꯥꯛꯄ ꯂꯥꯏꯟ ꯑꯃꯥ ꯊꯝꯂꯕ ꯃꯐꯝꯗ, ꯂꯥꯏꯟ ꯑꯗꯨ ꯃꯁꯤꯅꯥ ꯊꯤꯡꯖꯤꯜꯂꯤꯕ ꯃꯇꯝ ꯐꯥꯎꯕ ꯆꯠꯅꯩ, ꯑꯃꯁꯨꯡ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯄꯥꯛꯄ ꯑꯗꯨꯅꯥ ꯂꯩꯉꯥꯀꯏ (ꯀ꯭ꯂꯣꯖ 7.4.5)꯫ ꯔꯦꯐꯔꯦꯟꯁ ꯂꯥꯏꯟ ꯃꯔꯤ ꯆꯥꯡꯗꯝꯅꯩ (ꯁꯔꯨꯛ 7): ꯕꯥꯏ-ꯂꯣ 93-ꯒꯤ ꯂꯥꯞꯄꯒꯥ ꯂꯣꯌꯅꯅ ꯇꯨꯔꯦꯜꯒꯤ ꯃꯌꯥꯏ; ꯃꯁꯤꯒꯤ 6 m-ꯒꯥ ꯂꯣꯌꯅꯅ ꯄꯟꯒꯤ ꯃꯄꯥꯟꯒꯤ ꯇꯣ; ꯖꯣꯟ 1-ꯒꯥ ꯂꯣꯌꯅꯅ ꯂꯩꯔꯥꯏꯒꯤ ꯃꯊꯛ, ꯄꯟ ꯂꯩꯕ ꯔꯤꯆ ꯑꯃꯗ ꯄꯟꯒꯤ ꯂꯝꯒꯤ ꯃꯥꯏꯀꯩꯒꯤ ꯇꯣ ꯅꯠꯔꯒꯥ ꯄꯥꯠ ꯅꯠꯔꯒꯥ ꯄꯨꯈ꯭ꯔꯤ ꯑꯃꯒꯤ ꯉꯃꯈꯩ; ꯑꯃꯁꯨꯡ 10 m-ꯒꯥ ꯂꯣꯌꯅꯅ ꯑꯥꯎꯠꯐꯣꯜ ꯊꯤꯡꯂꯕ ꯐꯤꯚꯝꯗ 1% AEP-ꯒꯤ ꯁꯟꯗꯣꯛꯄ꯫ ꯆꯥꯡꯗꯝꯅꯕ ꯑꯁꯤ ꯃꯥꯏꯀꯩ ꯑꯅꯤꯃꯛꯇ ꯊꯕꯛ ꯇꯧꯏ (NEER-ꯒꯤ ꯄꯥꯕ)꯫ ꯇꯦꯕꯜ ꯑꯗꯨꯒꯤ ꯄꯟ ꯂꯩꯕ ꯇꯨꯔꯦꯜꯁꯤꯡꯗ, ꯇꯨꯔꯦꯜꯒꯤ ꯃꯌꯥꯏꯗꯒꯤ 30 m-ꯗꯒꯤ 62 m ꯐꯥꯎꯕ ꯕꯥꯏ-ꯂꯣꯒꯤ ꯂꯥꯞꯄꯁꯤꯡ, ꯅꯠꯔꯒꯥ ꯄꯟꯒꯤ ꯃꯄꯥꯟꯒꯤ ꯇꯣꯗꯒꯤ ꯃꯁꯤꯒꯤ 6 m ꯑꯁꯤꯅꯥ ꯃꯍꯧꯁꯥꯅꯥ ꯄꯥꯛꯄ ꯔꯤꯆꯁꯤꯡꯗ ꯍꯦꯟꯅꯥ ꯄꯥꯛꯄ ꯂꯥꯏꯟ ꯄꯤꯏ; ꯄꯟꯒꯤ ꯂꯝꯒꯤ ꯃꯥꯏꯀꯩꯒꯤ ꯇꯣꯗꯒꯤ ꯃꯦꯅꯨꯌꯦꯜꯒꯤ 15 m ꯑꯁꯤ ꯄꯟ ꯑꯁꯤ ꯇꯨꯔꯦꯜꯗꯒꯤ ꯌꯥꯝꯅꯥ ꯂꯥꯞꯅꯥ ꯂꯩꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯕꯥꯏ-ꯂꯣꯒꯤ 6 m-ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯀꯟꯏ; ꯑꯃꯁꯨꯡ ꯌꯧꯕ ꯔꯤꯆꯁꯤꯡꯗ, ꯑꯃꯁꯨꯡ ꯇꯦꯕꯜ ꯑꯗꯨꯅꯥ ꯊꯥꯗꯣꯛꯈꯤꯕ ꯇꯨꯔꯦꯜ, ꯁ꯭ꯇ꯭ꯔꯤꯝ ꯑꯃꯁꯨꯡ ꯄꯥꯠ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯃꯈꯣꯌꯒꯤ ꯃꯔꯛꯇ ꯈꯨꯒꯥ ꯇꯨꯔꯦꯜ, ꯆꯛꯄꯤ ꯇꯨꯔꯦꯜ (Chakpi), ꯆꯤꯡꯒꯤ ꯁ꯭ꯇ꯭ꯔꯤꯝꯁꯤꯡ, ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥ ꯑꯃꯁꯨꯡ ꯋꯥꯏꯁꯦꯜ ꯃꯥꯔꯤꯜ, ꯄꯥꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯄꯨꯈ꯭ꯔꯤꯁꯤꯡ, ꯃꯦꯅꯨꯌꯦꯜꯒꯤ 15 m ꯑꯁꯤꯅꯥ ꯂꯩꯉꯥꯀꯏ꯫ ꯀꯣꯔꯤꯗꯣꯔ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤ ꯃꯈꯥꯗ ꯑꯦꯞꯔꯨꯚ ꯇꯧꯔꯕ ꯑꯅꯧꯕ ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯑꯃꯁꯨꯡ ꯔꯤꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠꯇ ꯆꯠꯅꯩ, ꯂꯩꯔꯤꯕ ꯕꯤꯜꯗꯤꯡꯁꯤꯡꯗ ꯅꯠꯇꯦ, ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 7.4.7-ꯅꯥ ꯃꯁꯤꯒꯤ ꯃꯈꯥꯗ ꯚꯦꯔꯤꯌꯦꯟꯁ (variance) ꯑꯃꯠꯇꯥ ꯌꯥꯍꯟꯗꯦ꯫ ꯇꯝꯄꯥꯛꯀꯤ ꯂꯝꯒꯤ ꯂꯝ ꯌꯥꯝꯅꯥ ꯄ꯭ꯔꯥꯏꯚꯦꯠ ꯄꯠꯇꯥ ꯂꯝ (patta land) ꯑꯣꯏꯕꯅꯥ, ꯄ꯭ꯔꯥꯏꯚꯦꯠ ꯑꯣꯏꯕ ꯖꯣꯟ 1-ꯒꯤ ꯂꯝ ꯑꯃꯁꯨꯡ ꯔꯤꯖꯔꯚꯀꯤ ꯂꯝ ꯑꯁꯤ "ꯄꯣꯟꯗ, ꯈꯣꯡꯕꯥꯟ, ꯇꯨꯔꯦꯜꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯀꯦꯅꯦꯜꯁꯤꯡ" ꯍꯥꯌꯕ ꯌꯨꯖ ꯖꯣꯟꯗ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯗ ꯔꯤꯖꯔꯚ ꯇꯧꯏ, ꯅꯠꯔꯒꯥ ꯃꯄꯨꯒꯥ ꯌꯥꯅꯕꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯉꯥꯛꯊꯣꯀꯏ, ꯂꯦꯑꯥꯎꯠ ꯑꯦꯞꯔꯨꯚꯦꯜ ꯑꯃꯁꯨꯡ ꯂꯝꯒꯤ ꯔꯦꯀꯣꯔꯗꯁꯤꯡꯗ ꯔꯦꯀꯣꯔꯗ ꯇꯧꯗꯨꯅꯥ, ꯑꯃꯁꯨꯡ ꯂꯧꯊꯣꯛꯇꯦ; ꯃꯑꯣꯡ ꯑꯁꯤꯅꯥ ꯉꯥꯛꯊꯣꯛꯂꯕ ꯃꯐꯝꯗ, ꯀ꯭ꯂꯣꯖ 6.9.8(a)-ꯒꯤ ꯍꯣꯡꯗꯣꯀꯄ ꯑꯁꯤ ꯇꯥꯏꯇꯜ ꯍꯣꯡꯗꯣꯀꯄꯅꯥ ꯅꯠꯇꯅꯥ ꯔꯦꯀꯣꯔꯗ ꯇꯧꯔꯕ ꯌꯥꯅꯕ ꯑꯗꯨꯅꯥ ꯇꯧꯏ; ꯆꯤꯡꯒꯤ ꯂꯝꯁꯤꯡꯗ ꯃꯁꯤ ꯗꯤꯁꯇ꯭ꯔꯤꯛ ꯀꯥꯎꯟꯁꯤꯜꯒꯤ ꯂꯝ ꯌꯦꯟꯊꯣꯀꯄꯒꯤ ꯁꯛꯇꯤꯁꯤꯡꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯉꯥꯛꯊꯣꯀꯏ, ꯃꯈꯣꯌ ꯑꯁꯤ ꯄꯥꯟꯗꯝ ꯑꯁꯤꯒꯤꯗꯃꯛ ꯔꯤꯁꯔꯆ ꯇꯧꯈꯤꯗꯦ [TBC] (ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕ)꯫ ꯀꯣꯔꯤꯗꯣꯔ ꯑꯁꯤ ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯒꯤ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯗ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯁꯍꯔꯁꯤꯡꯒꯤ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯁꯤꯡꯗ ꯏꯔꯝꯒꯤ ꯂꯥꯏꯟꯁꯤꯡꯒꯤ ꯃꯅꯥꯛꯇ ꯂꯥꯞꯅꯥ ꯊꯝꯂꯕ ꯂꯝ ꯑꯣꯏꯅꯥ ꯎꯠꯄ ꯐꯩ, ꯑꯃꯁꯨꯡ OBPS-ꯗ TPD-ꯒꯤ ꯂꯦꯟꯗ-ꯌꯨꯖ ꯆꯦꯛ ꯑꯃꯁꯨꯡ ꯕꯤꯜꯗꯤꯡ ꯄꯥꯔꯃꯤꯠꯇ ꯆꯦꯛ ꯇꯧꯕ ꯐꯩ, ꯃꯐꯝ ꯑꯗꯨꯗ ꯄ꯭ꯂꯥꯟꯁꯤꯡꯅꯥ ꯃꯃꯥꯡꯗꯒꯤ "ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯜ/ꯑꯇꯣꯞꯄ ꯑꯣꯊꯣꯔꯤꯇꯤꯒꯤ ꯂꯩꯔꯤꯕ ꯄꯔꯃꯥꯅꯦꯟꯠ/ꯄꯛꯀꯥ ꯈꯣꯡꯕꯥꯟ ꯐꯥꯎꯕ ꯁꯥꯒꯠꯀꯗꯕ ꯃꯅꯨꯡ ꯑꯃꯁꯨꯡ ꯃꯄꯥꯟ ꯑꯅꯤꯃꯛꯀꯤ ꯑꯀꯨꯞꯄ ꯏꯔꯝꯒꯤ ꯄ꯭ꯂꯥꯟ" ("Detailed drainage plan for both internal and external required to be constructed up to the available permanent/pucca drain of municipal/other authority") ꯎꯠꯀꯗꯕꯅꯤ (ꯕꯥꯏ-ꯂꯣ 6(1)(D)), ꯑꯅꯧꯕ NOC ꯑꯃꯥ ꯑꯣꯏꯍꯟꯗꯅꯥ꯫
ꯔꯤꯖꯔꯚ ꯑꯁꯤ ꯃꯔꯨꯑꯣꯏ, ꯃꯔꯝꯗꯤ ꯃꯅꯤꯄꯨꯔꯒꯤ ꯁꯍꯔꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯃꯄꯨ ꯀꯌꯥꯒꯤ ꯃꯔꯛꯇ ꯈꯥꯌꯗꯣꯛꯂꯤ, ꯑꯃꯁꯨꯡ ꯔꯨꯜ ꯑꯃꯠꯇꯅꯥ ꯃꯈꯣꯌ ꯈꯥꯌꯗꯣꯛꯇꯦ꯫ ꯅꯣꯇꯤꯐꯤꯀꯦꯁꯟ ꯑꯃꯠꯇꯅꯥ ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥ, ꯋꯥꯏꯁꯦꯜ ꯃꯥꯔꯤꯜ ꯅꯠꯔꯒꯥ ꯁꯃꯨꯁꯥꯡ ꯅꯥꯂꯥ (Shamushang nallah) ꯑꯁꯤ ꯃꯄꯨ ꯑꯃꯗ ꯄꯤꯈꯤꯗꯦ (NEER-ꯒꯤ ꯄꯥꯕ), ꯑꯃꯁꯨꯡ AIIB-ꯅꯥ ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯒꯤ ꯏꯔꯝ ꯑꯁꯤ "ꯄ꯭ꯔꯥꯏꯃꯔꯤ ꯈꯣꯡꯕꯥꯟꯗ ꯆꯨꯝꯅꯥ ꯁꯝꯃꯤꯟꯅꯗꯦ꯫ ꯏꯔꯝ ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯂꯤꯉ꯭ꯛꯁꯤꯡ ꯃꯥꯡꯂꯤ" ("is not properly connected to the primary drain. Drainage system links are missing") ꯍꯥꯌꯅꯥ ꯐꯡꯈꯤ (AIIB, 2024)꯫ ꯃꯅꯤꯄꯨꯔ ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯂꯤꯇꯤꯖ ꯑꯦꯛꯠ, 1994-ꯒꯤ (Manipur Municipalities Act, 1994) ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤ ꯃꯇꯥꯡꯒꯤ ꯁꯦꯛꯁꯟꯁꯤꯡ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ ꯄꯥꯈꯤꯗꯦ [TBC]; ꯕꯥꯏ-ꯂꯣꯖꯅꯥ "ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯜ ꯈꯣꯡꯕꯥꯟ" ("municipal drain") ꯍꯥꯌꯅꯥ ꯉꯥꯡꯏ (ꯕꯥꯏ-ꯂꯣ 16)꯫ ꯑꯦꯞꯔꯤꯜ 2025-ꯗ ꯋꯥꯏꯁꯦꯜ ꯃꯥꯔꯤꯜ, ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥ ꯑꯃꯁꯨꯡ ꯅꯝꯕꯨꯜ ꯇꯨꯔꯦꯜꯒꯤ ꯃꯅꯥꯛꯇ ꯂꯩꯕ ꯂꯝ ꯈꯣꯞꯄꯁꯤꯡ ꯂꯧꯊꯣꯛꯅꯕ ꯑꯣꯔꯗꯔ ꯄꯤꯈꯤ, WRD-ꯅꯥ ꯃꯦꯁꯤꯅꯁꯤꯡ ꯄꯤꯒꯗꯕꯒꯥ ꯂꯣꯌꯅꯅ, ꯑꯃꯁꯨꯡ ꯋꯥꯏꯁꯦꯜ ꯃꯥꯔꯤꯜ ꯁꯦꯡꯗꯣꯀꯄ ꯑꯁꯤ LDA-ꯅꯥ ꯂꯃꯖꯤꯡꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ)꯫ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤ ꯄꯥꯟꯗꯝꯒꯤꯗꯃꯛ, ꯑꯃꯁꯨꯡ ꯁ꯭ꯇꯦꯠꯅꯥ ꯑꯁꯤꯒꯨꯝꯕ ꯔꯨꯜ ꯑꯃꯥ ꯊꯣꯛꯍꯟꯗ꯭ꯔꯤꯐꯥꯎꯕ [TBC], ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯃꯈꯥꯒꯤ ꯃꯑꯣꯡꯗ ꯄꯤꯔꯤ: ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯜ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ IMC ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯎꯔꯕꯟ ꯂꯣꯀꯜ ꯕꯣꯗꯤꯁꯤꯡꯗ ꯃꯈꯣꯌꯒꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯗ; ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ PWD-ꯗ, ꯃꯈꯣꯌꯒꯤ ꯃꯔꯛꯇ ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯗ AIIB ꯄ꯭ꯔꯣꯖꯦꯛꯠꯀꯤ "ꯃꯅꯥꯛ ꯑꯅꯤꯃꯛꯇ ꯀꯚꯔ ꯇꯧꯔꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ 547 km" ("547 km of both side stormwater covered drains") (AIIB, 2024), ꯑꯃꯁꯨꯡ ꯅꯦꯁꯅꯦꯜ ꯍꯥꯏꯋꯦꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯅꯦꯁꯅꯦꯜ-ꯍꯥꯏꯋꯦꯒꯤ ꯑꯦꯖꯦꯟꯁꯤꯁꯤꯡ-ꯗ; ꯇꯨꯔꯦꯜꯒꯤ ꯄꯟꯁꯤꯡ, ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡ, ꯂꯝꯐꯦꯜꯄꯥꯠ ꯑꯃꯁꯨꯡ ꯁꯃꯨꯁꯥꯡꯒꯤ ꯄꯝꯄꯤꯡ, ꯑꯃꯁꯨꯡ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡ ꯁꯦꯡꯗꯣꯛꯅꯕ ꯃꯦꯁꯤꯅꯁꯤꯡ WRD-ꯗ; ꯅꯝꯕꯨꯜ ꯇꯨꯔꯦꯜꯗ ꯆꯦꯟꯊꯔꯀꯄ ꯈꯣꯡꯕꯥꯟ 72-ꯒꯤ ꯏꯟꯇꯔꯁꯦꯞꯁꯟ ꯑꯃꯁꯨꯡ ꯗꯥꯏꯚꯔꯁꯟ, ꯑꯃꯁꯨꯡ ꯃꯁꯤꯒꯤ 16-ꯗꯒꯤ 17 MLD-ꯒꯤ ꯄ꯭ꯂꯥꯟꯠ DoECC-ꯗ; ꯁꯤꯋꯔꯁꯤꯡ PHED-ꯗ (ꯀ꯭ꯂꯣꯖ 8.9); ꯋꯥꯏꯁꯦꯜ ꯃꯥꯔꯤꯜ ꯁꯦꯡꯗꯣꯀꯄ, LDA-ꯅꯥ ꯂꯃꯖꯤꯡꯂꯤꯉꯩ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ), ꯑꯃꯁꯨꯡ ꯂꯣꯛꯇꯥꯛ ꯑꯃꯁꯨꯡ ꯂꯣꯛꯇꯥꯛ ꯑꯦꯛꯠꯀꯤ 236.21 km²-ꯒꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯁꯨꯡ ꯆꯦꯅꯦꯜ ꯈꯨꯗꯤꯡꯃꯛ LDA-ꯗ; ꯑꯃꯁꯨꯡ ꯆꯤꯡꯒꯤ ꯂꯝꯁꯤꯡꯗ, ꯄꯕ꯭ꯂꯤꯛ ꯋꯔꯛ ꯑꯃꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯃꯗꯨ ꯁꯥꯒꯠꯂꯤꯕ ꯗꯤꯄꯥꯔꯠꯃꯦꯟꯠꯇ, ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯗꯤꯁꯇ꯭ꯔꯤꯛ ꯀꯥꯎꯟꯁꯤꯜꯅꯥ ꯗꯦꯖꯤꯒꯅꯦꯠ ꯇꯧꯔꯕ ꯕꯣꯗꯤꯗ [TBC] (ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕ)꯫ ꯁꯍꯔ ꯈꯨꯗꯤꯡꯃꯛꯅꯥ ꯔꯤꯆ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯄꯤꯕ ꯑꯁꯤꯒꯤ ꯃꯈꯥꯗ ꯃꯁꯤꯒꯤ ꯃꯄꯨ, ꯃꯁꯤꯅꯥ ꯌꯧꯕ ꯇꯨꯔꯦꯜ, ꯃꯁꯤꯅꯥ ꯀ꯭ꯔꯣꯁ ꯇꯧꯕ ꯄꯟ ꯑꯃꯁꯨꯡ ꯃꯗꯨ ꯒꯦꯠ ꯅꯠꯔꯒꯥ ꯐ꯭ꯂꯦꯞ ꯒꯦꯠ ꯑꯃꯒꯤ ꯈꯨꯠꯊꯥꯡꯗꯅꯤ, ꯕꯥꯏ-ꯂꯣ 93-ꯒꯤ ꯕꯐꯔ ꯑꯃꯗ ꯂꯩꯕꯔꯥ, ꯃꯁꯤꯒꯤ ꯂꯝꯒꯤ ꯁ꯭ꯇꯦꯇꯁ (ꯄꯠꯇꯥ ꯅꯠꯔꯒꯥ ꯂꯩꯉꯥꯛꯀꯤ ꯂꯝ), ꯑꯃꯁꯨꯡ ꯃꯁꯤꯒꯤ ꯑꯥꯎꯠꯐꯣꯜ ꯄꯤꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯔꯦꯖꯤꯁ꯭ꯇꯔ (drain register) ꯑꯃꯥ ꯊꯝꯒꯗꯕꯅꯤ (ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕ)꯫ ꯀ꯭ꯂꯣꯖ 6.9.8(a)-ꯒꯤ ꯃꯈꯥꯗ, ꯋꯥꯇꯔ ꯔꯤꯁꯣꯔꯁꯦꯁ ꯗꯤꯄꯥꯔꯠꯃꯦꯟꯠꯇ ꯄꯤꯔꯕ ꯆꯦꯅꯦꯜ ꯑꯃꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯔꯤꯖꯔꯚ ꯑꯁꯤ ꯋꯥꯇꯔ ꯔꯤꯁꯣꯔꯁꯦꯁ ꯗꯤꯄꯥꯔꯠꯃꯦꯟꯠꯇ ꯍꯣꯡꯗꯣꯀꯏ ꯅꯠꯔꯒꯥ ꯃꯗꯨꯒꯤꯗꯃꯛ ꯉꯥꯛꯊꯣꯀꯏ꯫ ꯆꯦꯅꯦꯜ ꯑꯃꯒꯤ ꯁ꯭ꯇꯦꯇꯁ ꯑꯁꯤ ꯌꯥꯅꯕ ꯂꯩꯇꯕ ꯃꯐꯝꯗ, ꯀꯣꯔꯤꯗꯣꯔ ꯑꯁꯤꯅꯥ ꯆꯦꯅꯦꯜ ꯑꯗꯨ ꯃꯇꯨꯡ ꯏꯟꯅꯩ, ꯃꯁꯤꯒꯤ ꯃꯃꯤꯡ ꯅꯠꯇꯦ: ꯏꯝꯐꯥꯜꯒꯤ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡ ꯑꯁꯤ ꯃꯇꯝ ꯑꯃꯃꯛꯇ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ, ꯁꯤꯋꯦꯖ ꯄꯨꯕꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇꯨꯔꯦꯜꯒꯤ ꯄꯟ ꯑꯃꯗ ꯂꯩꯕ WRD-ꯒꯤ ꯒꯦꯠ ꯑꯃꯗ ꯂꯣꯏꯕ ꯆꯦꯅꯦꯜꯁꯤꯡꯅꯤ꯫ ꯁ꯭ꯇꯦꯠ ꯑꯁꯤꯗ ꯂꯩꯕ ꯀꯔꯤꯒꯨꯝꯕ ꯁꯍꯔ ꯑꯃꯒꯤꯗꯃꯛ ꯗꯤꯖꯥꯏꯟ ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗ ꯂꯩꯕ ꯑꯦꯞꯔꯨꯚ ꯇꯧꯔꯕ ꯏꯔꯝꯒꯤ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ ꯑꯃꯠꯇꯥ ꯐꯡꯈꯤꯗꯦ, ꯑꯃꯁꯨꯡ ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯒꯤ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯗ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯏꯔꯝꯒꯤ ꯁꯦꯛꯁꯟ ꯑꯃꯠꯇꯥ ꯂꯩꯇꯦ꯫ ꯃꯁꯤꯒꯤ ꯃꯅꯥꯛꯇ ꯂꯦꯃꯍꯧꯔꯤꯕ ꯂꯝꯗ ꯆꯥꯅꯕ ꯁꯥꯏꯖ ꯂꯦꯞꯂꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯆꯥꯎꯍꯟꯕ ꯌꯥꯗꯦ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯔꯤꯖꯔꯚ ꯑꯁꯤ ꯃꯊꯧ ꯇꯥꯕ ꯁꯥꯏꯖꯗ ꯌꯨꯝꯐꯝ ꯑꯣꯏꯏ꯫ ꯕꯦꯁꯤꯟ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ ꯑꯃꯥ ꯂꯧꯁꯤꯟꯗ꯭ꯔꯤꯐꯥꯎꯕ (ꯀ꯭ꯂꯣꯖ 6.9.6(b)), ꯀ꯭ꯂꯣꯖ 6.9.7-ꯒꯤ ꯃꯊꯧ ꯇꯥꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯥꯏꯖ ꯑꯁꯤ ꯁꯔꯨꯛ ꯑꯁꯤꯒꯤ ꯃꯈꯥꯗ ꯗꯤꯖꯥꯏꯅꯔꯅꯥ ꯊꯤꯔꯕ ꯁꯥꯏꯖ ꯑꯗꯨꯅꯤ꯫ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯂꯥꯏꯟ ꯇꯧꯔꯕ ꯅꯠꯔꯒꯥ ꯂꯥꯏꯟ ꯇꯧꯗꯕ ꯁꯦꯛꯁꯟ ꯑꯃꯥ ꯌꯥꯊꯡ ꯄꯤꯗꯦ, ꯀ꯭ꯂꯣꯖ 6.3.6(j) ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 9-ꯅꯥ ꯑꯉꯃꯕ ꯒ꯭ꯔꯦꯗꯤꯌꯦꯟꯠꯁꯤꯡꯗ ꯂꯥꯏꯅꯤꯡ ꯃꯊꯧ ꯇꯥꯕ ꯃꯐꯝꯁꯤꯡ ꯅꯠꯇꯕꯗꯤ꯫ ꯃꯁꯤꯅꯥ ꯁꯦꯛꯁꯟ ꯑꯁꯤꯅꯥ ꯀ꯭ꯂꯣꯖ 6.7.3 ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 9-ꯒꯤ ꯚꯦꯂꯣꯁꯤꯇꯤꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ ꯌꯧꯒꯗꯕꯅꯤ ꯍꯥꯌꯅꯥ ꯃꯊꯧ ꯇꯥꯏ, ꯑꯃꯁꯨꯡ ꯂꯥꯏꯟ ꯇꯧꯗꯕ ꯅꯠꯔꯒꯥ ꯄꯥꯝꯕꯤ ꯂꯩꯕ ꯁꯦꯛꯁꯟ ꯑꯃꯒꯤꯗꯃꯛ ꯆꯥꯅꯕ ꯄꯥꯛꯄ ꯔꯤꯖꯔꯚ ꯑꯃꯅꯥ ꯑꯣꯄꯁꯟ ꯑꯅꯤꯃꯛ ꯍꯥꯡꯗꯣꯛꯅꯥ ꯊꯝꯃꯤ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. ꯃꯊꯧ ꯇꯥꯕ 6.9.2(b)–(e), 6.9.3 ꯑꯃꯁꯨꯡ 6.9.4-ꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ ꯃꯅꯤꯄꯨꯔꯗ ꯄ꯭ꯂꯣꯠ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯑꯀꯣꯌꯕꯗ ꯀꯝꯄꯥꯎꯟꯗ ꯋꯣꯜꯁꯤꯡ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯗ ꯂꯩ ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌ ꯑꯁꯤ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯁꯤꯡ ꯊꯤꯡꯍꯜꯂꯤꯕ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯌꯥꯝꯅꯥ ꯊꯣꯀꯄ ꯃꯑꯣꯡꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ ꯑꯃꯅꯤ꯫ ꯋꯣꯜꯒꯤ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡꯒꯤꯗꯃꯛ 50% ꯕ꯭ꯂꯣꯀꯦꯖ ꯂꯧꯕ ꯑꯁꯤ ꯀ꯭ꯂꯣꯖ 6.6.3-ꯒꯤ ꯒ꯭ꯔꯦꯠ ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔꯒꯥ ꯃꯥꯟꯅꯅꯕ ꯊꯝꯂꯤ꯫ 3.5 m-ꯒꯤ ꯑꯦꯛꯁꯦꯁꯀꯤ ꯄꯥꯛꯄ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ, ꯑꯄꯤꯛꯄ ꯑꯦꯛꯁꯀꯦꯚꯦꯇꯔ ꯅꯠꯔꯒꯥ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯛꯅꯕ ꯒꯥꯔꯤ ꯑꯃꯒꯤꯗꯃꯛ ꯁꯥꯏꯖ ꯂꯦꯞꯂꯕ꯫ ꯆꯥꯡꯗꯝꯅꯅꯕ, APWA 5600 (2006, 5608.4)-ꯅꯥ ꯗꯤꯇꯦꯟꯁꯟ (detention) ꯐꯦꯁꯤꯂꯤꯇꯤꯁꯤꯡꯒꯤꯗꯃꯛ 15 ft (4.6 m ꯃꯔꯣꯜ)-ꯒꯤ ꯃꯦꯟꯇꯦꯅꯦꯟꯁꯀꯤ ꯑꯦꯛꯁꯦꯁ ꯁ꯭ꯇ꯭ꯔꯤꯞ ꯑꯃꯥ ꯃꯊꯧ ꯇꯥꯏ꯫
6.10 ꯁꯦꯒꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯅꯦꯝꯕ ꯃꯐꯝꯁꯤꯡꯗ ꯏꯁꯤꯡ ꯂꯦꯞꯄ
6.10.1 ꯃꯥꯏꯅꯔ ꯏꯚꯦꯟꯠ. ꯁꯦꯒ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯃꯥꯏꯅꯔ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯏꯟꯂꯦꯠꯁꯤꯡꯅꯥ (ꯀꯨꯞꯄ ꯂꯧꯔꯕ ꯃꯇꯨꯡꯗ) ꯇꯦꯕꯜ 6.2-ꯒꯤ ꯃꯅꯨꯡꯗ ꯏꯁꯤꯡ ꯂꯦꯞꯄꯒꯤ ꯁ꯭ꯞꯔꯦꯗꯒꯥ ꯂꯣꯌꯅꯅ ꯂꯧꯊꯣꯛꯀꯗꯕꯅꯤ꯫
6.10.2 1% AEP-ꯒꯤ ꯏꯚꯦꯟꯠ. ꯁꯦꯒ ꯈꯨꯗꯤꯡꯃꯛꯇ:
- (a) ꯏꯁꯤꯡ ꯂꯦꯞꯄꯒꯤ ꯑꯏꯡꯕ ꯑꯁꯤ ꯀꯦꯔꯤꯌꯦꯖꯋꯦꯒꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯑꯏꯡꯕ ꯃꯐꯝꯗ 350 mm-ꯗꯒꯤ ꯍꯦꯟꯂꯣꯏꯗꯕꯅꯤ;
- (b) ꯂꯩꯃꯥꯏꯒꯤ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯑꯃꯥ (ꯈꯨꯗꯝ ꯑꯣꯏꯅꯥ ꯅꯦꯝꯍꯜꯂꯕ ꯀꯔꯕ ꯑꯃꯁꯨꯡ ꯐꯨꯠꯄꯥꯊꯀꯤ ꯃꯊꯛꯇꯒꯤ ꯗꯦꯖꯤꯒꯅꯦꯠ ꯇꯧꯔꯕ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯑꯃꯗ) ꯄꯤꯒꯗꯕꯅꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯏꯁꯤꯡ ꯂꯦꯞꯄꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯁꯤ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯋꯥꯡꯅꯥ ꯍꯦꯟꯒꯠꯄ ꯌꯥꯔꯣꯏ; ꯑꯃꯁꯨꯡ
- (c) ꯁꯦꯒ ꯑꯗꯨꯒꯤ ꯑꯀꯣꯌꯕꯗ ꯂꯩꯕ ꯕꯤꯜꯗꯤꯡꯒꯤ ꯐ꯭ꯂꯣꯔ ꯂꯦꯚꯦꯜꯁꯤꯡꯅꯥ ꯀ꯭ꯂꯣꯖ 6.11 ꯌꯧꯒꯗꯕꯅꯤ꯫
6.10.3 ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯊꯤꯡꯂꯕ ꯐꯤꯚꯝꯒꯤ ꯆꯦꯛ. ꯁꯦꯒꯁꯤꯡꯗ, 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯂꯦꯞꯄꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯁꯤ ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯊꯤꯡꯂꯒꯥ ꯐ꯭ꯂꯣ ꯄꯨꯝꯅꯃꯛ ꯂꯩꯃꯥꯏꯒꯤ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯅꯥ ꯊꯣꯀꯄ ꯐꯤꯚꯝꯗꯁꯨ ꯊꯤꯒꯗꯕꯅꯤ꯫ ꯁꯦꯒ ꯑꯗꯨꯒꯤ ꯑꯀꯣꯌꯕꯗ ꯂꯩꯕ ꯐ꯭ꯂꯣꯔ ꯂꯦꯚꯦꯜꯁꯤꯡ ꯑꯁꯤ ꯏꯁꯤꯡ ꯂꯦꯞꯄꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯅꯤꯒꯤ ꯃꯔꯛꯇ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕ ꯑꯗꯨꯗꯒꯤ ꯊꯝꯒꯗꯕꯅꯤ꯫
6.10.4 ꯇ꯭ꯔꯦꯞ ꯇꯧꯔꯕ ꯁꯦꯒꯁꯤꯡ. ꯁꯦꯒ ꯑꯃꯗ ꯂꯩꯃꯥꯏꯒꯤ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯂꯩꯇꯕ ꯃꯐꯝꯗ, ꯏꯟꯂꯦꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯀꯟꯗ꯭ꯌꯨꯏꯠꯁꯤꯡꯅꯥ (ꯀꯨꯞꯄ ꯂꯧꯔꯕ ꯃꯇꯨꯡꯗ) 1% AEP-ꯒꯤ ꯐ꯭ꯂꯣ ꯄꯨꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯊꯧꯔꯥꯡ ꯑꯗꯨ ꯌꯥꯒꯗꯕꯅꯤ꯫
6.10.5 ꯔꯣꯗ ꯑꯟꯗꯔꯄꯥꯁꯁꯤꯡ. ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯂꯩꯕ ꯑꯟꯗꯔꯄꯥꯁꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯇ꯭ꯔꯦꯞ ꯇꯧꯔꯕ ꯁꯦꯒꯁꯤꯡꯗ:
- (a) 2% AEP (50-yr)-ꯒꯤ ꯐ꯭ꯂꯣꯒꯤꯗꯃꯛ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯔꯕ, 1% AEP-ꯒꯤ ꯐ꯭ꯂꯣꯗ ꯆꯦꯛ ꯇꯧꯔꯕ ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯃꯅꯥ (ꯒ꯭ꯔꯦꯚꯤꯇꯤꯅꯥ ꯏꯔꯝ ꯄꯤꯕ ꯌꯥꯗꯕ ꯃꯐꯝꯗ ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.9-ꯒꯤ ꯃꯈꯥꯗ ꯄꯝꯄꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ) ꯏꯔꯝ ꯄꯤꯒꯗꯕꯅꯤ;
- (b) ꯅꯦꯝꯕ ꯃꯐꯝ ꯑꯗꯨꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯐ꯭ꯂꯣ ꯊꯤꯡꯅꯕ ꯂꯥꯛꯂꯤꯕ ꯃꯥꯏꯀꯩ ꯑꯅꯤꯃꯛꯇ ꯐ꯭ꯂꯦꯉ꯭ꯀꯤꯡ ꯏꯟꯂꯦꯠꯁꯤꯡ ꯂꯩꯒꯗꯕꯅꯤ;
- (c) ꯇꯧꯕ ꯌꯥꯕ ꯃꯐꯝꯗ ꯋꯥꯡꯈꯠꯂꯕ ꯑꯦꯞꯔꯣꯆ ꯀ꯭ꯔꯦꯁ꯭ꯠꯁꯤꯡꯅꯥ ꯑꯀꯣꯌꯕꯒꯤ ꯂꯝꯕꯤꯁꯤꯡꯗꯒꯤ ꯏꯟꯐ꯭ꯂꯣꯗꯒꯤ ꯉꯥꯛꯊꯣꯛꯀꯗꯕꯅꯤ; ꯑꯃꯁꯨꯡ
- (d) ꯀꯦꯔꯤꯌꯦꯖꯋꯦꯗ 150 mm-ꯒꯤ ꯑꯏꯡꯕꯗ ꯊꯕꯛ ꯇꯧꯕ ꯑꯏꯡꯕꯒꯤ ꯃꯥꯔꯀꯔꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯃꯁꯥꯃꯛꯅꯥ ꯊꯕꯛ ꯇꯧꯕ ꯆꯦꯀꯁꯤꯅꯍꯟꯕ ꯅꯠꯔꯒꯥ ꯊꯤꯡꯕꯒꯤ ꯁꯤꯒꯅꯦꯂꯁꯤꯡ ꯂꯩꯒꯗꯕꯅꯤ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯊꯤꯡꯂꯕ ꯐꯤꯚꯝꯒꯤ ꯆꯦꯛ, ꯇ꯭ꯔꯦꯞ ꯇꯧꯔꯕ ꯁꯦꯒꯀꯤ ꯔꯨꯜ ꯑꯃꯁꯨꯡ ꯑꯟꯗꯔꯄꯥꯁꯀꯤ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡ ꯑꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ ꯔꯤꯁꯔꯆꯀꯤ ꯃꯇꯝꯗ ꯃꯅꯤꯄꯨꯔꯗ ꯏꯁꯤꯡꯅꯥ ꯌꯣꯠꯈꯤꯕ ꯔꯣꯗ ꯑꯟꯗꯔꯄꯥꯁ ꯑꯃꯒꯤ ꯔꯦꯀꯣꯔꯗ ꯑꯃꯠꯇꯥ ꯐꯡꯈꯤꯗꯦ [TBC]꯫ ꯂꯝꯕꯤꯁꯤꯡꯅꯥ ꯃꯃꯥꯡꯗꯒꯤ ꯃꯦꯖꯔ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯣꯏꯅꯥ ꯊꯕꯛ ꯇꯧꯔꯤ: ꯖꯨꯂꯥꯏ 2024-ꯗ ꯀꯨꯞꯂꯕ ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥꯅꯥ ꯏꯝꯐꯥꯜꯗ ꯅꯥꯒꯥꯔꯝ, ꯂꯥꯏꯐꯝ ꯈꯨꯅꯧ ꯑꯃꯁꯨꯡ ꯂꯥꯏꯔꯤꯛꯌꯦꯡꯕꯝ ꯂꯩꯀꯥꯏꯗ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯄꯨꯔꯛꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ), ꯑꯃꯁꯨꯡ AIIB-ꯒꯤ ꯂꯝꯕꯤꯒꯤ ꯄ꯭ꯔꯣꯖꯦꯛꯠꯅꯥ ꯃꯁꯤꯒꯤ ꯃꯍꯩ ꯑꯁꯤ "ꯏꯁꯤꯡ ꯏꯆꯥꯎꯅꯥ ꯃꯔꯝ ꯑꯣꯏꯗꯨꯅꯥ ꯂꯝꯕꯤ ꯁꯤꯖꯤꯟꯅꯕ ꯌꯥꯗꯕ ꯅꯨꯃꯤꯠꯀꯤ ꯃꯁꯤꯡ" ("Number of days of road unavailability due to flooding")-ꯅꯥ ꯊꯥꯖꯏ (AIIB, 2024)꯫ ꯀ꯭ꯂꯣꯖ 6.10.5(d)-ꯅꯥ ꯇꯦꯕꯜ 6.2-ꯒꯤ 150 mm-ꯒꯤ ꯀ꯭ꯔꯥꯎꯟ ꯑꯏꯡꯕꯒꯤ ꯂꯤꯃꯤꯠ ꯑꯁꯤ ꯇ꯭ꯔꯦꯐꯤꯛ ꯂꯦꯞꯀꯗꯕ ꯃꯐꯝ ꯑꯗꯨꯒꯥ ꯁꯝꯃꯤꯟꯅꯍꯜꯂꯤ꯫
6.11 ꯕꯤꯜꯗꯤꯡꯒꯤ ꯐ꯭ꯂꯣꯔ ꯂꯦꯚꯦꯜꯁꯤꯡ
6.11.1 ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯅꯦꯝꯕ ꯂꯩꯐꯝ ꯑꯣꯏꯕ ꯐ꯭ꯂꯣꯔ, ꯑꯃꯁꯨꯡ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯗ ꯏꯁꯤꯡ ꯆꯡꯕ ꯌꯥꯕ ꯍꯥꯡꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛ (ꯊꯣꯡꯁꯤꯡ, ꯚꯦꯟꯇꯤꯂꯦꯇꯔꯁꯤꯡ, ꯕꯦꯁꯃꯦꯟꯠ ꯔꯦꯝꯞꯁꯤꯡ, ꯂꯤꯐꯠ ꯄꯤꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁꯔꯚꯤꯁ ꯆꯡꯐꯝꯁꯤꯡ) ꯑꯁꯤ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ 0.5 m ꯃꯊꯛꯇ ꯂꯩꯒꯗꯕꯅꯤ꯫
6.11.2 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯁꯤ ꯃꯈꯥꯒꯤꯁꯤꯡꯒꯤ ꯃꯔꯛꯇ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯋꯥꯡꯕ ꯑꯗꯨꯅꯤ:
- (a) ꯕꯤꯜꯗꯤꯡ ꯑꯗꯨꯒꯤ ꯃꯅꯥꯛꯇ ꯂꯩꯕ ꯂꯝꯕꯤ ꯅꯠꯔꯒꯥ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯗ 1% AEP-ꯒꯤ ꯃꯦꯖꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯂꯦꯚꯦꯜ (ꯀ꯭ꯂꯣꯖ 6.9 ꯑꯃꯁꯨꯡ 6.10, ꯁꯦꯒꯁꯤꯡꯗ ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯊꯤꯡꯂꯕ ꯐꯤꯚꯝꯒꯤ ꯆꯦꯛ ꯌꯥꯑꯣꯅꯥ);
- (b) ꯇꯨꯔꯦꯜ, ꯆꯦꯅꯦꯜ, ꯄꯨꯈ꯭ꯔꯤ ꯅꯠꯔꯒꯥ ꯏꯁꯤꯡ ꯂꯩꯐꯝ (waterbody) ꯑꯃꯍꯦꯛꯇꯒꯤ 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜ (ꯁꯔꯨꯛ 7); ꯑꯃꯁꯨꯡ
- (c) ꯁꯔꯨꯛ 5-ꯒꯤ ꯇꯦꯜꯋꯥꯇꯔꯒꯥ ꯂꯣꯌꯅꯅ 1% AEP-ꯒꯤ ꯂꯦꯚꯦꯜ; ꯑꯃꯁꯨꯡ
- (d) ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯀ꯭ꯂꯣꯖ 7.3.4-ꯒꯤ ꯃꯈꯥꯗ 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯑꯏꯡꯕꯒꯤ ꯃꯦꯞ ꯑꯃꯥ ꯂꯧꯔꯕ ꯃꯐꯝꯗ, ꯄ꯭ꯂꯣꯠꯇ ꯂꯩꯕ ꯂꯩꯃꯥꯏꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯃꯁꯨꯡ ꯃꯦꯞ ꯇꯧꯔꯕ 1% AEP-ꯒꯤ ꯑꯏꯡꯕ꯫
6.11.3 ꯂꯦꯚꯦꯜ ꯊꯤꯗꯕ ꯃꯐꯝꯗ ꯗꯤꯐꯣꯜꯠ. ꯁꯔꯨꯛ 1-ꯒꯤ ꯊ꯭ꯔꯦꯁꯍꯣꯜꯗꯁꯤꯡꯗꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯄ꯭ꯂꯣꯠ ꯑꯃꯒꯤꯗꯃꯛ, ꯅꯠꯔꯒꯥ ꯄ꯭ꯂꯣꯠ ꯑꯗꯨꯒꯤꯗꯃꯛ 1% AEP-ꯒꯤ ꯂꯦꯚꯦꯜ ꯊꯤꯗꯕ ꯃꯐꯝꯗ, ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯅꯦꯝꯕ ꯂꯩꯐꯝ ꯑꯣꯏꯕ ꯐ꯭ꯂꯣꯔ ꯑꯃꯁꯨꯡ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡ ꯑꯁꯤ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ ꯃꯈꯥꯒꯤ ꯑꯅꯤꯒꯤ ꯃꯔꯛꯇ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕ ꯑꯗꯨ ꯑꯣꯏꯒꯗꯕꯅꯤ:
- (a) ꯄ꯭ꯂꯣꯠ ꯑꯗꯨꯅꯥ ꯃꯃꯥꯏ ꯌꯦꯡꯂꯤꯕ ꯂꯝꯕꯤꯒꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯋꯥꯡꯕ ꯀ꯭ꯔꯥꯎꯟ ꯂꯦꯚꯦꯜꯗꯒꯤ 0.65 m ꯃꯊꯛꯇ; ꯑꯃꯁꯨꯡ
- (b) ꯂꯧꯔꯕ 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯑꯏꯡꯕꯒꯤ ꯃꯦꯞ ꯑꯃꯅꯥ ꯄ꯭ꯂꯣꯠ ꯑꯗꯨ ꯌꯥꯎꯔꯕ ꯃꯐꯝꯗ, ꯂꯩꯃꯥꯏꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯃꯁꯨꯡ ꯃꯦꯞ ꯇꯧꯔꯕ 1% AEP-ꯒꯤ ꯑꯏꯡꯕ ꯑꯃꯁꯨꯡ 0.5 m꯫
ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯂꯣꯀꯦꯜ ꯁ꯭ꯇꯗꯤ ꯑꯃꯅꯥ ꯃꯍꯨꯠ ꯁꯤꯟꯗ꯭ꯔꯤꯐꯥꯎꯕ, ꯁ꯭ꯇꯦꯠꯅꯥ ꯑꯦꯞꯔꯨꯚ ꯇꯧꯔꯕ ꯃꯦꯞ ꯑꯃꯥ ꯅꯠꯔꯒꯥ ꯃꯣꯗꯦꯜ ꯇꯧꯔꯕ 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯑꯏꯡꯕꯒꯤ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯅꯦꯁꯅꯦꯜ ꯃꯦꯞ ꯑꯃꯥ (ꯈꯨꯗꯝ ꯑꯣꯏꯅꯥ India Flood Atlas) ꯒꯨꯝꯕ ꯔꯤꯖꯅꯦꯜ ꯃꯦꯞ ꯑꯃꯥ ꯂꯧꯕ ꯌꯥꯏ꯫ ꯁ꯭ꯇꯣꯔꯝ ꯁꯔꯖ (storm surge) ꯃꯣꯗꯦꯜ ꯇꯧꯗꯕ ꯃꯦꯞ ꯑꯃꯥ ꯀ꯭ꯂꯣꯖ 6.11.6-ꯒꯤ ꯃꯍꯨꯠꯇ ꯁꯤꯖꯤꯟꯅꯔꯣꯏꯗꯕꯅꯤ꯫
6.11.4 ꯕꯦꯁꯃꯦꯟꯠꯁꯤꯡ. ꯕꯦꯁꯃꯦꯟꯠ ꯔꯦꯝꯞ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯀ꯭ꯔꯦꯁ꯭ꯠ ꯑꯃꯁꯨꯡ ꯕꯦꯁꯃꯦꯟꯠꯀꯤ ꯍꯥꯡꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯁꯤꯜ ꯑꯁꯤꯅꯥ ꯀ꯭ꯂꯣꯖ 6.11.1 ꯌꯧꯒꯗꯕꯅꯤ꯫ ꯕꯦꯁꯃꯦꯟꯠꯀꯤ ꯏꯔꯝ ꯑꯁꯤ ꯅꯟ-ꯔꯤꯇꯔꯟ ꯚꯥꯜꯚ ꯑꯃꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯂꯩꯃꯥꯏꯒꯤ ꯈꯣꯡꯕꯥꯟꯗ ꯄꯝꯞꯅꯥ ꯊꯥꯗꯣꯛꯀꯗꯕꯅꯤ꯫
6.11.5 ꯁꯔꯚꯤꯁꯁꯤꯡ. ꯕꯤꯜꯗꯤꯡ ꯑꯃꯗ ꯁꯦꯕꯥ ꯄꯤꯕ ꯏꯂꯦꯛꯇ꯭ꯔꯤꯀꯦꯜ ꯄꯦꯅꯦꯜꯁꯤꯡ, ꯇ꯭ꯔꯥꯟꯁꯐꯣꯔꯃꯔꯁꯤꯡ, ꯁ꯭ꯇꯦꯟꯗꯕꯥꯏ ꯖꯦꯅꯦꯔꯦꯇꯔꯁꯤꯡ, ꯂꯤꯐꯠ ꯃꯦꯁꯤꯅꯔꯤ ꯑꯃꯁꯨꯡ ꯄꯝꯞꯁꯤꯡꯅꯥ ꯀ꯭ꯂꯣꯖ 6.11.1 ꯌꯧꯒꯗꯕꯅꯤ꯫
6.11.6 ꯀꯣꯁ꯭ꯇꯦꯜ ꯕꯦꯟꯗ (coastal band). ꯀꯣꯁ꯭ꯇꯦꯜ ꯕꯦꯟꯗ ꯍꯥꯌꯕꯁꯤ ꯁꯃꯨꯗ꯭ꯔꯒꯤ ꯃꯃꯥꯡꯒꯤ ꯍꯥꯏ ꯇꯥꯏꯗ ꯂꯥꯏꯟꯗꯒꯤ (High Tide Line) ꯂꯝꯃꯥꯏꯀꯩꯗ 500 m-ꯒꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯕ ꯂꯝꯅꯤ, CRZ Notification, 2019-ꯅꯥ ꯑꯔꯊ ꯄꯤꯔꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ, ꯑꯦꯞꯔꯨꯚ ꯇꯧꯔꯕ ꯀꯣꯁ꯭ꯇꯦꯜ ꯖꯣꯟ ꯃꯦꯅꯦꯖꯃꯦꯟꯠ ꯄ꯭ꯂꯥꯟꯗ ꯈꯥꯌꯗꯣꯛꯈꯤꯕ ꯍꯥꯏ ꯇꯥꯏꯗ ꯂꯥꯏꯟꯒꯥ ꯂꯣꯌꯅꯅ꯫ ꯁꯔꯚꯦ ꯑꯣꯐ ꯏꯟꯗꯤꯌꯥꯒꯤ ꯍꯖꯥꯔꯗ ꯂꯥꯏꯟ (Hazard Line) ꯑꯁꯤ 500 m-ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯂꯝꯃꯥꯏꯀꯩꯗ ꯂꯩꯔꯕ ꯃꯐꯝꯗ, ꯕꯦꯟꯗ ꯑꯁꯤ ꯍꯖꯥꯔꯗ ꯂꯥꯏꯟ ꯐꯥꯎꯕ ꯆꯥꯎꯏ꯫ ꯀꯣꯁ꯭ꯇꯦꯜ ꯕꯦꯟꯗꯀꯤ ꯃꯅꯨꯡꯗ, ꯀ꯭ꯂꯣꯖ 6.11.1-ꯗꯒꯤ 6.11.5 ꯐꯥꯎꯕꯒꯤ ꯃꯊꯛꯇ:
- (a) ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯅꯦꯝꯕ ꯂꯩꯐꯝ ꯑꯣꯏꯕ ꯐ꯭ꯂꯣꯔ ꯑꯃꯁꯨꯡ ꯍꯥꯡꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛ ꯑꯁꯤ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ ꯀꯣꯁ꯭ꯇꯦꯜ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ 0.5 m ꯃꯊꯛꯇꯁꯨ ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯁꯤ 1% AEP-ꯒꯤ ꯁ꯭ꯇꯤꯜ-ꯋꯥꯇꯔ ꯂꯦꯚꯦꯜ (ꯀ꯭ꯂꯣꯖ 5.7.3(b), ꯑꯍꯦꯟꯕ 5A) ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 5.7.4-ꯒꯤ ꯁꯤ-ꯂꯦꯚꯦꯜ ꯑꯦꯂꯥꯎꯑꯦꯟꯁꯀꯤ ꯑꯅꯤ ꯊꯣꯛ (ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 0.6 m)ꯅꯤ, ꯃꯔꯝꯗꯤ ꯕꯤꯜꯗꯤꯡꯁꯤꯡꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯂꯥꯏꯐ ꯆꯍꯤ 50-ꯗꯒꯤ ꯍꯦꯟꯏ (ꯀ꯭ꯂꯣꯖ 5.7.4(c));
- (b) ꯄ꯭ꯂꯣꯠ ꯑꯗꯨꯅꯥ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯕꯤꯆꯇ ꯃꯃꯥꯏ ꯌꯦꯡꯂꯕ ꯃꯐꯝꯗ, ꯀꯣꯁ꯭ꯇꯦꯜ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜꯗ ꯁꯥꯏꯠ ꯁ꯭ꯇꯗꯤ ꯑꯃꯗꯒꯤ ꯋꯦꯚ ꯁꯦꯠ-ꯑꯞ (wave set-up) ꯌꯥꯎꯒꯗꯕꯅꯤ;
- (c) ꯀ꯭ꯂꯣꯖ 6.11.5-ꯗ ꯂꯤꯁ꯭ꯠ ꯇꯧꯔꯕ ꯂꯩꯐꯝ ꯑꯣꯏꯕ ꯀꯥ, ꯏꯂꯦꯛꯇ꯭ꯔꯤꯀꯦꯜ ꯁꯔꯚꯤꯁ ꯔꯨꯝ ꯅꯠꯔꯒꯥ ꯄ꯭ꯂꯥꯟꯠ ꯑꯃꯠꯇꯥ ꯕꯦꯁꯃꯦꯟꯠ ꯑꯃꯗ ꯊꯝꯂꯣꯏꯗꯕꯅꯤ; ꯑꯃꯁꯨꯡ
- (d) ꯕꯦꯁꯃꯦꯟꯠꯀꯤ ꯍꯥꯡꯕ ꯃꯐꯝ, ꯔꯦꯝꯞ ꯀ꯭ꯔꯦꯁ꯭ꯠ ꯑꯃꯁꯨꯡ ꯚꯦꯟꯇꯤꯂꯦꯁꯟꯒꯤ ꯍꯥꯡꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯅꯥ ꯀ꯭ꯂꯣꯖ 6.11.6(a) ꯌꯧꯒꯗꯕꯅꯤ꯫
ꯀ꯭ꯂꯣꯖ 6.11.6-ꯅꯥ CRZ Notification-ꯅꯥ ꯊꯤꯡꯂꯤꯕ ꯀꯟꯁ꯭ꯇ꯭ꯔꯛꯁꯟ ꯑꯃꯠꯇꯥ ꯌꯥꯍꯟꯗꯦ꯫ ꯑꯅꯤꯃꯛ ꯆꯠꯅꯔꯕ ꯃꯐꯝꯗ, ꯍꯦꯟꯅꯥ ꯀꯟꯕ ꯑꯗꯨꯅꯥ ꯂꯩꯉꯥꯀꯏ꯫
ꯃꯃꯤ 6.5 — ꯀꯣꯁ꯭ꯇꯦꯜ ꯕꯦꯟꯗ: 1% AEP-ꯒꯤ ꯁ꯭ꯇꯤꯜ-ꯋꯥꯇꯔ ꯂꯦꯚꯦꯜ, ꯁꯤ-ꯂꯦꯚꯦꯜ ꯑꯦꯂꯥꯎꯑꯦꯟꯁꯀꯤ ꯑꯅꯤ ꯊꯣꯛ, ꯄ꯭ꯂꯣꯠ ꯑꯗꯨꯅꯥ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯕꯤꯆꯇ ꯃꯃꯥꯏ ꯌꯦꯡꯂꯕ ꯃꯐꯝꯗ ꯋꯦꯚ ꯁꯦꯠ-ꯑꯞ ꯑꯃꯁꯨꯡ 0.5 m ꯐ꯭ꯔꯤꯕꯣꯔꯗꯇꯒꯤ ꯁꯦꯝꯈꯤꯕ ꯃꯤꯅꯤꯃꯝ ꯐ꯭ꯂꯣꯔ ꯂꯦꯚꯦꯜ; ꯑꯃꯁꯨꯡ ꯍꯥꯏ ꯇꯥꯏꯗ ꯂꯥꯏꯟꯗꯒꯤ 500 m ꯐꯥꯎꯕ ꯅꯠꯔꯒꯥ ꯍꯖꯥꯔꯗ ꯂꯥꯏꯟ ꯍꯦꯟꯅꯥ ꯂꯝꯃꯥꯏꯀꯩꯗ ꯂꯩꯔꯕꯗꯤ ꯃꯗꯨ ꯐꯥꯎꯕ ꯕꯦꯟꯗꯀꯤ ꯆꯥꯎꯕ (ꯀ꯭ꯂꯣꯖ 6.11.6)꯫ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ ꯑꯅꯧꯅꯥ ꯁꯦꯝꯕ ꯗ꯭ꯔꯣꯏꯡ, CRZ Notification, 2019 (para 1(i) and Annexure IV) ꯑꯃꯁꯨꯡ PUB Singapore, Code of Practice on Surface Water Drainage (7th ed.), cl. 2.1.1-ꯗꯒꯤ ꯍꯣꯡꯗꯣꯛꯂꯒꯥ ꯂꯧꯈꯤꯕ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. 1% AEP-ꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ 0.5 m-ꯒꯤ ꯐ꯭ꯔꯤꯕꯣꯔꯗ ꯑꯁꯤ DID Malaysia 2008-ꯒꯤ ꯆꯦꯛꯂꯤꯁ꯭ꯠ ꯃꯇꯨꯡ ꯏꯟꯅꯔꯤ (ꯄ꯭ꯂꯦꯠꯐꯣꯔꯝ ꯑꯃꯁꯨꯡ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯅꯦꯝꯕ ꯐ꯭ꯂꯣꯔ 100-yr ARI + 0.5 m-ꯗ)꯫ ꯃꯁꯤ 1% ꯁ꯭ꯇꯦꯖꯀꯤ ꯃꯊꯛꯇ 1 ft (0.3 m ꯃꯔꯣꯜ)-ꯒꯤ APWA 5600 (2006, 5601.8 A2)-ꯒꯤ ꯃꯊꯧ ꯇꯥꯕꯗꯒꯤ ꯍꯦꯟꯏ꯫ ꯀ꯭ꯂꯣꯖ 6.11.3-ꯒꯤ 0.65 m-ꯒꯤ ꯗꯤꯐꯣꯜꯠ ꯑꯁꯤ ꯁꯔꯨꯛ ꯑꯁꯤꯒꯤ ꯑꯇꯣꯞꯄ ꯂꯤꯃꯤꯠꯁꯤꯡꯗꯒꯤ ꯂꯧꯔꯕꯅꯤ, ꯇꯣꯉꯥꯟꯅꯥ ꯍꯧꯔꯛꯐꯝ ꯄꯤꯔꯕ ꯅꯠꯇꯦ: ꯀ꯭ꯔꯥꯎꯟꯗ 1%-ꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯁꯤ 150 mm ꯐꯥꯎꯕ ꯑꯣꯏꯕ ꯌꯥꯏ (ꯇꯦꯕꯜ 6.2), ꯃꯁꯤꯒꯤ ꯃꯊꯛꯇ 0.5 m-ꯒꯤ ꯐ꯭ꯔꯤꯕꯣꯔꯗ꯫ ꯃꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜ ꯂꯩꯇꯕ ꯄ꯭ꯂꯣꯠꯁꯤꯡꯗ ꯆꯠꯅꯩ꯫ URDPFI (2015)-ꯅꯁꯨ ꯃꯁꯤꯒꯤ ꯐ꯭ꯂꯗ-ꯄ꯭ꯂꯦꯟ ꯖꯣꯅꯤꯡꯗ ꯃꯤꯅꯤꯃꯝ ꯄ꯭ꯂꯤꯟꯊ ꯂꯦꯚꯦꯜꯁꯤꯡ ꯑꯁꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯐ꯭ꯔꯤꯀ꯭ꯋꯦꯟꯁꯤꯒꯥ ꯁꯝꯃꯤꯟꯅꯍꯜꯂꯤ, ꯃꯁꯤ ꯁꯔꯨꯛ 7-ꯗ ꯌꯥꯎꯏ꯫
ꯀ꯭ꯂꯣꯖ 6.11.3(b)-ꯅꯥ ꯂꯣꯀꯦꯜ ꯁ꯭ꯇꯗꯤ ꯂꯩꯇꯕ ꯃꯐꯝꯗ ꯑꯄꯤꯛꯄ ꯄ꯭ꯂꯣꯠ ꯑꯃꯅꯥ ꯂꯝꯕꯤꯒꯤ ꯂꯦꯚꯦꯜ ꯈꯛꯇꯗꯒꯤ ꯈꯟꯊꯕꯒꯤ ꯃꯍꯨꯠꯇ ꯃꯦꯞ ꯇꯧꯔꯕ 1% AEP-ꯒꯤ ꯑꯏꯡꯕ ꯁꯤꯖꯤꯟꯅꯕ ꯌꯥꯍꯜꯂꯤ꯫ ꯃꯣꯗꯦꯜ ꯇꯧꯔꯕ ꯅꯦꯁꯅꯦꯜ ꯃꯦꯞꯁꯤꯡ ꯑꯁꯤ ꯃꯆꯥꯟ ꯆꯥꯎꯏ (30 m ꯃꯔꯣꯜ), ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌꯒꯤ ꯃꯔꯛꯇ ꯌꯥꯝꯅꯥ ꯅꯣꯡ ꯑꯃꯁꯨꯡ ꯇꯨꯔꯦꯜꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯃꯣꯗꯦꯜ ꯇꯧꯏ ꯑꯗꯨꯕꯨ ꯁ꯭ꯇꯣꯔꯝ ꯁꯔꯖ ꯃꯣꯗꯦꯜ ꯇꯧꯗꯦ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ 6.11.3-ꯅꯥ ꯔꯣꯗ-ꯀ꯭ꯔꯥꯎꯟꯒꯤ ꯆꯦꯛ ꯊꯝꯃꯤ ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 6.11.6-ꯅꯥ ꯇꯣꯉꯥꯟꯕ ꯀꯣꯁ꯭ꯇꯦꯜ ꯔꯨꯜ ꯑꯃꯥ ꯊꯝꯂꯤ꯫
ꯀ꯭ꯂꯣꯖ 6.11.6-ꯒꯤ ꯀꯣꯁ꯭ꯇꯦꯜ ꯕꯦꯟꯗ ꯑꯁꯤꯅꯥ CRZ Notification, 2019-ꯒꯤ 500 m-ꯒꯤ ꯂꯥꯏꯟ ꯁꯤꯖꯤꯟꯅꯩ (G.S.R. 37(E), para 1(i): "ꯍꯥꯏ ꯇꯥꯏꯗ ꯂꯥꯏꯟꯗꯒꯤ ... ꯂꯝꯃꯥꯏꯀꯩꯗ 500 ꯃꯤꯇꯔ ꯐꯥꯎꯕ ꯂꯝꯒꯤ ꯑꯦꯔꯤꯌꯥ" ["the land area from High Tide Line ... to 500 meters on the landward side"]), ꯃꯔꯝꯗꯤ ꯀꯣꯁ꯭ꯇꯦꯜ ꯑꯣꯊꯣꯔꯤꯇꯤ ꯈꯨꯗꯤꯡꯃꯛꯅꯥ ꯃꯃꯥꯡꯗꯒꯤ ꯃꯁꯤ ꯃꯦꯞ ꯇꯧꯔꯤ ꯑꯃꯁꯨꯡ ꯃꯁꯤꯒꯤꯗꯃꯛ ꯑꯅꯧꯕ ꯁꯔꯚꯦ ꯃꯊꯧ ꯇꯥꯗꯦ꯫ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯆꯥꯎꯕ ꯑꯃꯁꯨꯡ ꯁꯣꯔꯂꯥꯏꯅꯒꯤ ꯍꯣꯡꯂꯛꯄ ꯎꯠꯅꯕ ꯁꯔꯚꯦ ꯑꯣꯐ ꯏꯟꯗꯤꯌꯥꯅꯥ ꯈꯥꯌꯗꯣꯛꯈꯤꯕ ꯍꯖꯥꯔꯗ ꯂꯥꯏꯟ ꯑꯁꯤꯅꯥ ꯃꯁꯤ ꯍꯦꯟꯅꯥ ꯂꯝꯃꯥꯏꯀꯩꯗ ꯂꯩꯔꯕ ꯃꯐꯝꯗ ꯕꯦꯟꯗ ꯑꯗꯨ ꯆꯥꯎꯍꯜꯂꯤ (CRZ Notification, 2019, Annexure IV)꯫ ꯕꯦꯟꯗ ꯑꯁꯤꯅꯥ ꯀꯣꯁ꯭ꯇꯦꯜ ꯂꯦꯚꯦꯜ ꯑꯁꯤ ꯅꯣꯡ ꯆꯨꯕꯒꯤ ꯃꯦꯞꯇꯒꯤ ꯅꯠꯇꯅꯥ ꯁꯔꯨꯛ 5-ꯒꯤ ꯖꯣꯏꯟꯠ-ꯀꯦꯁꯀꯤ ꯁ꯭ꯇꯤꯜ-ꯋꯥꯇꯔ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯂꯧꯏ꯫ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯑꯁꯤꯅꯥ ꯐꯤꯚꯝ ꯑꯗꯨ ꯎꯠꯂꯤ: ꯀꯣꯁ꯭ꯇꯦꯜ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯑꯃꯥ ꯁꯃꯨꯗ꯭ꯔꯒꯥ ꯂꯣꯌꯅꯅ ꯍꯦꯟꯒꯠꯂꯀꯏ, ꯇꯥꯏꯗ ꯋꯥꯡꯂꯤꯉꯩꯗ ꯏꯔꯝ ꯄꯤꯕ ꯌꯥꯗꯦ, ꯑꯃꯁꯨꯡ ꯁꯃꯨꯗ꯭ꯔꯒꯥ ꯂꯣꯌꯅꯅ ꯍꯦꯟꯅꯥ ꯍꯦꯟꯒꯠꯂꯛꯀꯅꯤ꯫ ꯁꯤꯡꯒꯥꯄꯨꯔꯅꯁꯨ ꯃꯑꯣꯡ ꯑꯗꯨꯃꯛ ꯂꯧꯏ, ꯅꯣꯡ ꯆꯨꯕꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜ ꯀꯔꯤ ꯑꯣꯏꯔꯕꯁꯨ, ꯃꯁꯤꯒꯤ ꯈꯥ ꯊꯡꯕ ꯀꯣꯁ꯭ꯠꯇ ꯗꯦꯇꯝꯒꯤ ꯃꯊꯛꯇ 4.0 m ꯑꯃꯁꯨꯡ ꯑꯋꯥꯡ ꯊꯡꯕ ꯀꯣꯁ꯭ꯠꯇ 4.5 m-ꯒꯤ ꯐꯤꯛꯁ ꯇꯧꯔꯕ ꯃꯤꯅꯤꯃꯝ ꯄ꯭ꯂꯦꯠꯐꯣꯔꯝ ꯂꯦꯚꯦꯜ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ (PUB Code of Practice on Surface Water Drainage, 7th ed., cl. 2.1.1)꯫ ꯀꯣꯁ꯭ꯇꯦꯜ ꯁ꯭ꯇꯦꯠ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯇꯥꯏꯗ ꯑꯃꯁꯨꯡ ꯁꯔꯖꯀꯤ ꯂꯦꯚꯦꯜꯁꯤꯡ ꯑꯁꯤ ꯃꯁꯤꯒꯤ ꯀꯣꯁ꯭ꯠꯀꯤ ꯃꯅꯥꯛꯇ ꯐꯤꯛꯁ ꯇꯧꯔꯕ ꯂꯦꯚꯦꯜ ꯑꯃꯈꯛꯇꯒꯤꯗꯃꯛ ꯌꯥꯝꯅꯥ ꯇꯣꯉꯥꯟꯅꯩ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯃꯗꯨꯒꯤ ꯃꯍꯨꯠꯇ ꯊꯤꯔꯕ ꯁ꯭ꯇꯤꯜ-ꯋꯥꯇꯔ ꯂꯦꯚꯦꯜ ꯁꯤꯖꯤꯟꯅꯩ꯫ ꯁꯤ-ꯂꯦꯚꯦꯜ ꯑꯦꯂꯥꯎꯑꯦꯟꯁꯀꯤ ꯑꯅꯤ ꯊꯣꯛ ꯁꯤꯖꯤꯟꯅꯕ ꯑꯁꯤꯅꯥ ꯀ꯭ꯂꯣꯖ 5.7.4(c)-ꯒꯤ ꯁꯦꯟꯁꯤꯇꯤꯚꯤꯇꯤ ꯀꯦꯁ ꯑꯁꯤ ꯗꯤꯖꯥꯏꯟ ꯀꯦꯁ ꯑꯣꯏꯅꯥ ꯆꯠꯍꯜꯂꯤ, ꯃꯔꯝꯗꯤ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯥ, ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯨꯝꯅꯥ ꯅꯠꯇꯅꯥ, ꯃꯇꯨꯡꯗ ꯂꯥꯏꯅꯥ ꯋꯥꯡꯈꯠꯍꯟꯕ ꯌꯥꯗꯦ꯫ 6.11.6(c)-ꯗ ꯂꯩꯕ ꯕꯦꯁꯃꯦꯟꯠꯀꯤ ꯊꯤꯡꯕ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ: ꯀꯣꯁ꯭ꯇꯦꯜ ꯕꯦꯟꯗꯇ ꯂꯩꯕ ꯕꯦꯁꯃꯦꯟꯠ ꯑꯃꯥ ꯅꯣꯡꯗꯒꯤ ꯈꯛꯇꯅꯠꯇꯅꯥ ꯁꯃꯨꯗ꯭ꯔꯗꯒꯤꯁꯨ ꯃꯄꯨꯟꯏ, ꯑꯃꯁꯨꯡ ꯇꯥꯏꯗꯅꯥ ꯂꯣꯛ ꯇꯧꯔꯕ ꯑꯥꯎꯠꯐꯣꯜ ꯑꯃꯗ ꯄꯝꯞꯅꯥ ꯊꯥꯗꯣꯛꯄ ꯌꯥꯗꯦ꯫ ꯃꯅꯤꯄꯨꯔꯗ ꯀꯣꯁ꯭ꯠ, ꯍꯥꯏ ꯇꯥꯏꯗ ꯂꯥꯏꯟ ꯑꯃꯁꯨꯡ ꯀꯣꯁ꯭ꯇꯦꯜ ꯔꯦꯒꯨꯂꯦꯁꯟ ꯖꯣꯟ ꯂꯩꯇꯦ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯁ꯭ꯇꯦꯠ ꯑꯁꯤꯗ ꯀꯣꯁ꯭ꯇꯦꯜ ꯕꯦꯟꯗ ꯑꯁꯤ ꯑꯍꯥꯡꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 6.11.6 ꯃꯐꯝ ꯑꯗꯨꯗ ꯆꯠꯅꯗꯦ꯫ ꯃꯗꯨꯒꯤ ꯃꯍꯨꯠꯇ ꯀ꯭ꯂꯣꯖ 6.11.3 ꯑꯃꯁꯨꯡ 6.11.4 ꯃꯔꯨꯑꯣꯏ꯫ ꯃꯣꯗꯦꯜ ꯕꯥꯏ-ꯂꯣꯖꯅꯥ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯊꯣꯀꯄ ꯌꯥꯕ ꯂꯝꯒꯤꯗꯃꯛ ꯄ꯭ꯂꯤꯟꯊ ꯑꯃꯥ ꯊꯝꯂꯤ: "ꯁꯍꯔꯁꯤꯡꯒꯤ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯗ ꯈꯡꯗꯣꯛꯂꯕ ꯍꯥꯏ ꯐ꯭ꯂꯗ ꯔꯤꯁ꯭ꯛ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯗ, ꯄ꯭ꯂꯤꯟꯊ ꯂꯦꯚꯦꯜ ꯑꯁꯤ ꯑꯀꯣꯌꯕꯒꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯒꯤ ꯍꯥꯏꯌꯦꯁ꯭ꯠ ꯐ꯭ꯂꯗ ꯂꯦꯚꯦꯜꯗꯒꯤ 1m ꯃꯊꯛꯇ ꯂꯩꯕ ꯐꯩ" ("In high Flood Risk Areas identified in the Master Plan of the towns, the plinth level should be above 1m above the highest flood level of the surrounding areas") (ꯃꯣꯗꯦꯜꯒꯤ ꯕꯥꯏ-ꯂꯣ 94 [TBC: ꯂꯣꯀꯜ ꯕꯣꯗꯤꯅꯥ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯕꯥꯏ-ꯂꯣꯖꯇ ꯅꯝꯕꯔ ꯑꯃꯁꯨꯡ ꯇꯦꯛꯁꯇ ꯆꯦꯛ ꯇꯧꯒꯗꯕꯅꯤ]), ꯑꯃꯁꯨꯡ IMC (3rd Amendment) 2024-ꯒꯤ ꯗ꯭ꯔꯥꯐꯠꯅꯥ ꯔꯨꯜ ꯑꯗꯨꯃꯛ "ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯒꯤ ꯔꯤꯁ꯭ꯛ-ꯏꯟꯐꯣꯔꯝꯗ GIS-ꯕꯦꯖ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯗ ꯈꯡꯗꯣꯛꯂꯕ ꯍꯥꯏ ꯐ꯭ꯂꯗ ꯔꯤꯁ꯭ꯛ ꯑꯦꯔꯤꯌꯥꯁꯤꯡ" ("High Flood Risk Areas identified in the Risk-Informed GIS-Based Master Plan for Greater Imphal")-ꯒꯥ ꯁꯝꯃꯤꯟꯅꯍꯜꯂꯤ (93.2; ꯑꯔꯣꯏꯕ ꯁ꯭ꯇꯦꯇꯁ ꯀꯟꯐꯥꯔꯝ ꯇꯧꯈꯤꯗꯦ [TBC])꯫ ꯑꯦꯔꯤꯌꯥ ꯑꯗꯨꯁꯤꯡ ꯎꯠꯀꯗꯕ ꯏꯝꯐꯥꯜ ꯑꯃꯁꯨꯡ ꯃꯣꯏꯔꯥꯡꯒꯤ ꯔꯤꯁ꯭ꯛ-ꯏꯟꯐꯣꯔꯝꯗ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯄꯥꯈꯤꯗꯦ [TBC], ꯑꯃꯁꯨꯡ ꯀꯔꯤꯒꯨꯝꯕ ꯁꯍꯔ ꯑꯃꯒꯤꯗꯃꯛ ꯂꯣꯀꯜ ꯑꯣꯊꯣꯔꯤꯇꯤ ꯑꯃꯒꯤ "ꯍꯥꯏꯌꯦꯁ꯭ꯠ ꯐ꯭ꯂꯗ ꯂꯦꯚꯦꯜ" ("highest flood level") ꯑꯃꯠꯇꯥ ꯐꯡꯈꯤꯗꯦ [TBC], ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯕꯥꯏ-ꯂꯣ ꯑꯁꯤꯅꯥ ꯁꯥꯒꯠꯀꯗꯕ ꯂꯦꯚꯦꯜ ꯑꯃꯠꯇꯥ ꯄꯤꯗꯦ; ꯑꯃꯁꯨꯡ 15 ꯁꯦꯞꯇꯦꯝꯕꯔ 2025-ꯗ ꯂꯤꯂꯣꯡꯗ ꯂꯩꯕ ꯇꯨꯔꯦꯜ ꯑꯃꯁꯨꯡ ꯏꯊꯥꯏꯗ ꯂꯩꯕ ꯃꯅꯤꯄꯨꯔ ꯇꯨꯔꯦꯜꯅꯥ ꯃꯈꯣꯌꯒꯤꯗꯃꯛ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯍꯥꯏꯌꯦꯁ꯭ꯠ ꯐ꯭ꯂꯗ ꯂꯦꯚꯦꯜꯁꯤꯡ ꯍꯦꯟꯊꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ)꯫ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ, ꯂꯦꯚꯦꯜ ꯑꯗꯨ ꯁꯥꯏꯠ ꯑꯗꯨꯗ ꯀ꯭ꯂꯣꯖ 6.11.2-ꯒꯤ 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯣꯏꯅꯥ ꯂꯧꯏ, ꯀ꯭ꯂꯣꯖ 5.8.5-ꯒꯤ ꯄꯟꯅꯥ ꯂꯣꯛ ꯇꯧꯔꯕ, ꯂꯦꯛ ꯑꯃꯁꯨꯡ ꯄꯟ ꯀꯛꯄꯒꯤ ꯀꯦꯁꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ ꯊꯤꯔꯕ ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 5.8.5(a) ꯅꯠꯔꯒꯥ (c)-ꯒꯤ ꯆꯦꯛ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯅꯦꯝꯗꯕ, ꯅꯠꯔꯒꯥ ꯊꯤꯗꯕ ꯃꯐꯝꯗ, ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯃꯥꯔꯛꯁꯤꯡꯗꯒꯤ ꯁꯔꯚꯦ ꯇꯧꯔꯕ ꯍꯥꯏꯌꯦꯁ꯭ꯠ ꯐ꯭ꯂꯗ ꯂꯦꯚꯦꯜ, ꯃꯁꯤꯒꯤ ꯍꯧꯔꯛꯐꯝ ꯐꯣꯡꯗꯣꯛꯂꯒꯥ; ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ 0.5 m ꯃꯊꯛꯇ ꯂꯩꯕ ꯀ꯭ꯂꯣꯖ 6.11.1-ꯒꯤ ꯐ꯭ꯂꯣꯔ ꯂꯦꯚꯦꯜꯁꯤꯡ ꯑꯁꯤ ꯕꯥꯏ-ꯂꯣꯒꯤ ꯄ꯭ꯂꯤꯟꯊꯇꯒꯤ ꯋꯥꯡꯕ ꯃꯐꯝꯗ ꯃꯈꯣꯌꯅꯥ ꯂꯩꯉꯥꯀꯏ (ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕ)꯫ ꯇꯨꯔꯦꯜꯒꯤ ꯄꯟ ꯑꯃꯒꯤ ꯃꯇꯨꯡꯗ ꯂꯦꯚꯦꯜ ꯑꯁꯤ ꯒꯦꯠꯁꯤꯡ ꯊꯤꯡꯂꯕ ꯐꯤꯚꯝꯗ ꯏꯁꯤꯡ ꯂꯦꯞꯂꯕ ꯑꯦꯔꯤꯌꯥꯒꯤ ꯑꯗꯨꯅꯤ, ꯑꯃꯁꯨꯡ ꯄꯟ ꯀꯛꯄꯒꯤꯗꯃꯛ, ꯄꯟꯒꯤ ꯃꯥꯏꯀꯩ ꯑꯇꯣꯞꯄꯗ ꯂꯩꯕ ꯇꯨꯔꯦꯜꯒꯤ ꯂꯦꯚꯦꯜꯅꯤ (ꯀ꯭ꯂꯣꯖ 5.8.5(a))꯫ ꯃꯣꯗꯦꯜꯅꯥ ꯕꯦꯁꯃꯦꯟꯠ ꯑꯃꯒꯤ ꯑꯔꯊ ꯄꯤꯔꯤ (ꯕꯥꯏ-ꯂꯣ 2(11)) ꯑꯃꯁꯨꯡ ꯃꯩ ꯉꯥꯀꯄꯒꯤꯗꯃꯛ ꯁꯦꯠꯕꯦꯛ ꯂꯥꯏꯟꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ ꯕꯦꯁꯃꯦꯟꯠꯁꯤꯡ ꯌꯥꯍꯜꯂꯤ, ꯑꯗꯨꯕꯨ ꯕꯥꯏ-ꯂꯣꯖꯀꯤ ꯔꯨꯜ ꯑꯃꯠꯇꯅꯥ ꯅꯦꯝꯕ ꯅꯠꯔꯒꯥ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯊꯣꯀꯄ ꯌꯥꯕ ꯂꯝꯗꯒꯤ ꯕꯦꯁꯃꯦꯟꯠꯁꯤꯡ ꯂꯧꯊꯣꯛꯇꯦ (NEER-ꯒꯤ ꯄꯥꯕ): ꯏꯝꯐꯥꯜ ꯇꯝꯄꯥꯛꯀꯤ ꯂꯝꯗ ꯕꯦꯁꯃꯦꯟꯠ ꯑꯃꯥ ꯀ꯭ꯂꯣꯖ 6.11.3 ꯑꯃꯁꯨꯡ 6.11.4 ꯌꯧꯔꯕ ꯑꯃꯁꯨꯡ ꯗꯤꯖꯥꯏꯟ ꯂꯩꯃꯥꯏꯒꯤ ꯃꯈꯥꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯂꯦꯚꯦꯜ ꯂꯩꯃꯥꯏꯒꯤ ꯂꯦꯚꯦꯜꯗ ꯂꯩꯅꯥ ꯁꯔꯨꯛ 4-ꯒꯤ ꯐ꯭ꯂꯣꯇꯦꯁꯟ ꯆꯦꯛ ꯌꯧꯔꯕ ꯃꯐꯝꯗ ꯈꯛꯇꯃꯛ ꯌꯥꯏ (ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕ)꯫ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜ ꯊꯤꯗꯕ ꯃꯐꯝꯗ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯅꯦꯝꯕ ꯂꯩꯐꯝ ꯑꯣꯏꯕ ꯐ꯭ꯂꯣꯔ ꯑꯃꯁꯨꯡ ꯍꯥꯡꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛ ꯔꯣꯗ ꯀ꯭ꯔꯥꯎꯟꯗꯒꯤ 0.65 m ꯃꯊꯛꯇ ꯊꯝꯕ ꯀ꯭ꯂꯣꯖ 6.11.3, ꯑꯃꯁꯨꯡ ꯂꯦꯚꯦꯜ ꯑꯗꯨꯃꯛ, ꯅꯠꯔꯒꯥ 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ 0.5 m ꯃꯊꯛꯇ, ꯕꯦꯁꯃꯦꯟꯠ ꯔꯦꯝꯞ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯀ꯭ꯔꯦꯁ꯭ꯠ ꯑꯃꯁꯨꯡ ꯕꯦꯁꯃꯦꯟꯠꯀꯤ ꯍꯥꯡꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯁꯤꯜꯗ ꯆꯠꯍꯅꯕ ꯀ꯭ꯂꯣꯖ 6.11.4 ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ ꯑꯃꯁꯨꯡ ꯕꯥꯏ-ꯂꯣꯖꯇ ꯍꯥꯄꯆꯤꯜꯂꯤ꯫ ꯆꯤꯡꯒꯤ ꯁꯥꯏꯠ ꯑꯃꯗ ꯔꯣꯗ ꯀ꯭ꯔꯥꯎꯟ ꯑꯁꯤ ꯃꯇꯝ ꯄꯨꯝꯕꯗ ꯆꯨꯝꯕ ꯔꯦꯐꯔꯦꯟꯁ ꯅꯠꯇꯦ: ꯂꯝꯕꯤ ꯑꯃꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯅꯥ ꯂꯝꯕꯤꯒꯤ ꯔꯟꯑꯣꯐ ꯂꯧꯏ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯀ꯭ꯂꯣꯖ 6.11.2(a)-ꯅꯥ ꯃꯁꯤꯒꯤ ꯐ꯭ꯂꯣꯔ ꯑꯃꯁꯨꯡ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡ ꯑꯁꯤ ꯃꯁꯤꯒꯤ ꯃꯅꯥꯛꯇꯒꯤ ꯆꯠꯄ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯒꯤ 1% AEP-ꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯊꯝꯃꯤ, ꯀ꯭ꯂꯣꯖ 6.3.6(l)-ꯒꯤ ꯃꯊꯛ ꯊꯡꯕ ꯃꯥꯏꯀꯩꯒꯤ ꯗꯥꯏꯚꯔꯁꯟ ꯂꯩꯔꯒꯥ, ꯑꯃꯁꯨꯡ ꯅꯥꯄꯣꯝ ꯑꯃꯗ ꯀꯛꯇꯨꯅꯥ ꯁꯥꯕ ꯐ꯭ꯂꯣꯔ ꯅꯠꯔꯒꯥ ꯕꯦꯁꯃꯦꯟꯠ ꯑꯃꯗ ꯀ꯭ꯂꯣꯖ 4.11-ꯒꯤ ꯆꯤꯡꯒꯤ ꯔꯨꯜꯒꯤ ꯖꯤꯑꯣꯇꯦꯛꯅꯤꯀꯦꯜ ꯁꯔꯇꯤꯐꯤꯀꯦꯠꯁꯨ ꯃꯊꯧ ꯇꯥꯏ꯫ ꯇꯨꯔꯦꯜꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯈꯣꯡꯁꯤꯡꯒꯤ ꯃꯅꯥꯛꯇ ꯑꯃꯁꯨꯡ ꯄꯥꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯄꯨꯈ꯭ꯔꯤꯁꯤꯡꯒꯤ ꯑꯀꯣꯌꯕꯗ, ꯁꯔꯨꯛ 7-ꯒꯤ ꯂꯥꯏꯟꯁꯤꯡꯁꯨ ꯆꯠꯅꯩ꯫
6.12 ꯀꯜꯚꯔꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯂꯝꯕꯤ ꯀ꯭ꯔꯣꯁꯤꯡꯁꯤꯡ
6.12.1 ꯗꯤꯖꯥꯏꯟ AEP. ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯋꯥꯇꯔꯋꯦ ꯑꯃꯒꯤ ꯃꯊꯛꯇ ꯂꯝꯕꯤ ꯑꯃꯥ ꯄꯨꯕ ꯀꯜꯚꯔꯠ ꯅꯠꯔꯒꯥ ꯊꯣꯡ ꯑꯃꯅꯥ ꯂꯝꯕꯤꯒꯤ ꯀ꯭ꯂꯥꯁ ꯑꯗꯨꯒꯤꯗꯃꯛ ꯇꯦꯕꯜ 6.1-ꯒꯤ ꯗꯤꯖꯥꯏꯟ AEP-ꯒꯤ ꯐ꯭ꯂꯣ ꯑꯗꯨ ꯂꯝꯕꯤꯒꯤ ꯃꯊꯛꯇ ꯆꯦꯟꯍꯟꯗꯅꯥ, ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.4-ꯒꯤ ꯍꯦꯗꯋꯥꯇꯔꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ ꯆꯠꯍꯅꯒꯗꯕꯅꯤ꯫ ꯋꯥꯇꯔꯋꯦ ꯑꯁꯤ ꯁ꯭ꯇꯦꯠ ꯍꯥꯏꯋꯦ ꯅꯠꯔꯒꯥ ꯅꯦꯁꯅꯦꯜ ꯍꯥꯏꯋꯦꯒꯤ ꯀ꯭ꯔꯣꯁꯤꯡ ꯑꯃꯥ ꯑꯣꯏꯔꯕ ꯃꯐꯝꯗ, ꯗꯤꯖꯥꯏꯟ AEP ꯑꯁꯤ ꯁ꯭ꯄꯦꯟ ꯑꯗꯨꯒꯤꯗꯃꯛ IRC:SP:42-2014 §7.1.4-ꯒꯤ ꯑꯗꯨꯗꯒꯤꯁꯨ ꯍꯟꯊꯔꯣꯏꯗꯕꯅꯤ꯫ ꯍꯦꯟꯅꯥ ꯌꯥꯝꯗꯅꯥ ꯊꯣꯀꯄ AEP ꯑꯗꯨꯅꯥ ꯂꯩꯉꯥꯀꯏ꯫
6.12.2 ꯆꯦꯛ ꯏꯚꯦꯟꯠ ꯑꯃꯁꯨꯡ 1% AEP. ꯆꯦꯛ ꯏꯚꯦꯟꯠ ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯏꯚꯦꯟꯠꯇ, ꯀ꯭ꯔꯣꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯂꯝꯕꯤ ꯄꯨꯟꯅꯕꯅꯥ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯆꯠꯍꯅꯒꯗꯕꯅꯤ:
- (a) ꯔꯣꯗ ꯀ꯭ꯔꯥꯎꯟꯗ ≤ 150 mm ꯑꯃꯁꯨꯡ ꯂꯝꯕꯤꯒꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯑꯏꯡꯕ ꯃꯐꯝꯗ ≤ 350 mm-ꯒꯤ ꯑꯣꯚꯔꯇꯣꯄꯤꯡꯒꯤ ꯑꯏꯡꯕꯒꯥ ꯂꯣꯌꯅꯅ;
- (b) ꯇꯦꯕꯜ 6.3-ꯒꯤ ꯍꯖꯥꯔꯗꯀꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ;
- (c) ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯏꯚꯦꯀꯨꯌꯦꯁꯟ ꯔꯨꯠ ꯑꯣꯏꯕ ꯑꯥꯔꯇꯤꯔꯤꯌꯦꯜ ꯂꯝꯕꯤꯁꯤꯡꯗ ꯑꯣꯚꯔꯇꯣꯄꯤꯡ ꯑꯃꯠꯇꯥ ꯌꯥꯎꯗꯅꯥ; ꯑꯃꯁꯨꯡ
- (d) ꯁꯣꯛꯍꯜꯂꯕ ꯃꯄꯨꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯦꯞꯔꯨꯚꯤꯡ ꯑꯣꯊꯣꯔꯤꯇꯤꯅꯥ ꯌꯥꯗ꯭ꯔꯕꯗꯤ, ꯃꯊꯛ ꯊꯡꯕ ꯃꯐꯝꯒꯤ ꯕꯤꯜꯗꯤꯡ ꯅꯠꯔꯒꯥ ꯄ꯭ꯔꯣꯄꯔꯇꯤꯒꯤ ꯉꯃꯈꯩ ꯑꯃꯍꯦꯛꯇꯗ 1% AEP-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯂꯦꯚꯦꯜ ꯑꯁꯤ ꯂꯩꯔꯤꯕ ꯐꯤꯚꯝꯒꯤ ꯂꯦꯚꯦꯜꯗꯒꯤ ꯍꯦꯟꯒꯠꯍꯟꯗꯅꯥ꯫
6.12.3 ꯑꯣꯚꯔꯇꯣꯄꯤꯡ ꯌꯥꯍꯟꯗꯕ ꯃꯐꯝꯁꯤꯡ. 1% AEP-ꯒꯤ ꯏꯚꯦꯟꯠꯇ ꯑꯣꯚꯔꯇꯣꯄꯤꯡ ꯑꯁꯤ ꯑꯣꯚꯔꯇꯣꯄꯤꯡ ꯁꯦꯛꯁꯟꯒꯤ ꯃꯈꯥ ꯊꯡꯕ ꯃꯐꯝꯗ ꯒꯥꯔꯗ ꯔꯦꯜ ꯊꯝꯂꯕꯗꯤ ꯅꯠꯇꯅꯥ, ꯁ꯭ꯇ꯭ꯔꯛꯆꯔꯒꯤ ꯁ꯭ꯄꯦꯟ 6 m-ꯗꯒꯤ ꯍꯟꯊꯕ ꯑꯃꯁꯨꯡ 1% AEP-ꯒꯤ ꯄꯤꯛ ꯐ꯭ꯂꯣ 7 m³/s-ꯗꯒꯤ ꯍꯦꯟꯗꯕ ꯃꯐꯝꯗ ꯈꯛꯇꯃꯛ ꯌꯥꯏ꯫ ꯑꯇꯣꯞꯄ ꯃꯐꯝꯁꯤꯡꯗ, ꯀ꯭ꯔꯣꯁꯤꯡ ꯑꯁꯤꯅꯥ 1% AEP-ꯒꯤ ꯐ꯭ꯂꯣ ꯑꯣꯚꯔꯇꯣꯄꯤꯡ ꯌꯥꯎꯗꯅꯥ ꯆꯠꯍꯅꯒꯗꯕꯅꯤ꯫
6.12.4 ꯕ꯭ꯂꯣꯀꯦꯖꯒꯤ ꯆꯦꯛ. 1% AEP-ꯒꯤ ꯆꯦꯛ ꯑꯁꯤ ꯊꯤꯡꯂꯕ ꯏꯟꯂꯦꯠ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ ꯑꯃꯨꯛ ꯍꯟꯅꯥ ꯇꯧꯒꯗꯕꯅꯤ:
- (a) ꯁ꯭ꯄꯦꯟ ꯅꯠꯔꯒꯥ ꯗꯥꯏꯃꯤꯇꯔ 1.5 m-ꯗꯒꯤ ꯍꯟꯊꯕ ꯀꯜꯚꯔꯠꯁꯤꯡꯒꯤꯗꯃꯛ ꯏꯟꯂꯦꯠ ꯑꯦꯔꯤꯌꯥꯒꯤ 50% ꯊꯤꯡꯂꯕ; ꯑꯃꯁꯨꯡ
- (b) ꯍꯦꯟꯅꯥ ꯆꯥꯎꯕ ꯀꯜꯚꯔꯠꯁꯤꯡꯒꯤꯗꯃꯛ 20% ꯊꯤꯡꯂꯕ꯫
ꯆꯦꯛ ꯑꯁꯤꯒꯤ ꯃꯍꯩꯁꯤꯡꯅꯥ ꯀ꯭ꯂꯣꯖ 6.12.2(a) ꯑꯃꯁꯨꯡ (d) ꯌꯧꯒꯗꯕꯅꯤ꯫
6.12.5 ꯃꯤꯅꯤꯃꯝ ꯁꯥꯏꯖ. ꯄꯕ꯭ꯂꯤꯛ ꯂꯝꯕꯤꯁꯤꯡꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯀꯜꯚꯔꯠꯁꯤꯡ ꯑꯁꯤ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ ꯗꯥꯏꯃꯤꯇꯔ 900 mm, ꯅꯠꯔꯒꯥ ꯕꯣꯛꯁ ꯀꯜꯚꯔꯠꯁꯤꯡꯒꯤꯗꯃꯛ 900 mm × 900 mm ꯑꯣꯏꯒꯗꯕꯅꯤ꯫
6.12.6 ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯗꯤꯖꯥꯏꯟ. ꯏꯟꯂꯦꯠ ꯑꯃꯁꯨꯡ ꯑꯥꯎꯠꯂꯦꯠ ꯀꯟꯇ꯭ꯔꯣꯜ, ꯇꯦꯜꯋꯥꯇꯔ, ꯂꯝꯕꯤꯒꯤ ꯑꯣꯚꯔꯇꯣꯄꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯥꯎꯠꯂꯦꯠ ꯉꯥꯛꯊꯣꯀꯄ ꯌꯥꯑꯣꯅꯥ ꯀꯜꯚꯔꯠꯀꯤ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛꯁ ꯑꯁꯤꯅꯥ ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.4 ꯑꯃꯁꯨꯡ 9.6 ꯃꯇꯨꯡ ꯏꯟꯅꯒꯗꯕꯅꯤ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. ꯗꯤꯖꯥꯏꯟ AEP-ꯁꯤꯡ ꯑꯁꯤ ꯇꯦꯕꯜ 6.1-ꯒꯤꯅꯤ꯫ ꯑꯣꯚꯔꯇꯣꯄꯤꯡꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡ ꯑꯁꯤ ꯇꯦꯕꯜ 6.2-ꯒꯤ ꯂꯝꯕꯤꯒꯤ ꯑꯏꯡꯕꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯅꯤ꯫ ꯀ꯭ꯂꯣꯖ 6.12.3-ꯒꯤ ꯁ꯭ꯄꯦꯟ ꯑꯃꯁꯨꯡ ꯐ꯭ꯂꯣꯒꯤ ꯊ꯭ꯔꯦꯁꯍꯣꯜꯗ ꯑꯁꯤ APWA 5600 (2006)-ꯒꯤ SI-ꯗ ꯍꯣꯡꯗꯣꯀꯄꯅꯤ: ꯃꯈꯥ ꯊꯡꯕ ꯃꯐꯝꯗ ꯒꯥꯔꯗ ꯐꯦꯟꯁ ꯊꯝꯂꯕꯗꯤ ꯅꯠꯇꯅꯥ, ꯁ꯭ꯇ꯭ꯔꯛꯆꯔꯒꯤ ꯁ꯭ꯄꯦꯟ 20 ft-ꯗꯒꯤ ꯍꯟꯊꯕ ꯑꯃꯁꯨꯡ 1%-ꯒꯤ ꯄꯤꯛ 250 cfs ꯅꯠꯔꯒꯥ ꯃꯁꯤꯗꯒꯤ ꯍꯟꯊꯕ ꯃꯐꯝꯗ ꯈꯛꯇꯃꯛ ꯑꯣꯚꯔꯇꯣꯄꯤꯡ ꯌꯥꯏ꯫ IRC:SP:42-2014 (§7.1.4)-ꯅꯥ 2 m ꯐꯥꯎꯕ ꯁ꯭ꯄꯦꯟꯒꯤ NH/SH ꯀꯜꯚꯔꯠꯁꯤꯡꯒꯤꯗꯃꯛ 25-yr ꯑꯃꯁꯨꯡ 2–6 m-ꯒꯤ ꯁ꯭ꯄꯦꯟꯁꯤꯡꯒꯤꯗꯃꯛ 50-yr ꯊꯝꯂꯤ꯫ ꯀ꯭ꯂꯣꯖ 6.12.4-ꯒꯤ ꯕ꯭ꯂꯣꯀꯦꯖꯒꯤ ꯄꯔꯁꯦꯟꯇꯦꯖꯁꯤꯡ ꯑꯃꯁꯨꯡ 900 mm-ꯒꯤ ꯃꯤꯅꯤꯃꯝ ꯁꯥꯏꯖ ꯑꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ 50%-ꯒꯤ ꯚꯦꯜꯌꯨ ꯑꯁꯤ ꯒ꯭ꯔꯦꯠ ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔꯒꯥ ꯃꯥꯟꯅꯩ꯫
6.13 ꯃꯅꯤꯄꯨꯔꯒꯤ ꯀꯟꯁ꯭ꯇ꯭ꯔꯛꯁꯟ ꯄ꯭ꯔꯦꯛꯇꯤꯁꯀꯤ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡ
6.13.1 ꯀꯚꯔ ꯇꯧꯔꯕ ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ. ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯐꯨꯠꯄꯥꯊ ꯑꯃꯥ ꯑꯣꯏꯍꯟꯕ ꯁ꯭ꯂꯦꯕꯁꯤꯡꯅꯥ ꯀꯚꯔ ꯇꯧꯔꯕ ꯃꯐꯝꯗ:
- (a) ꯃꯁꯤ ꯀꯚꯔ ꯁ꯭ꯂꯦꯕꯀꯤ ꯁꯣꯐꯤꯠ ꯐꯥꯎꯕ ꯊꯥꯖꯕ ꯇꯦꯕꯜ 6.7-ꯒꯤ ꯐ꯭ꯔꯤꯕꯣꯔꯗꯒꯥ ꯂꯣꯌꯅꯅ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯆꯦꯅꯦꯜ ꯑꯃꯥ ꯑꯣꯏꯅꯥ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯃꯁꯤꯒꯤ HGL-ꯅꯥ ꯐꯨꯠꯄꯥꯊ ꯑꯃꯁꯨꯡ ꯏꯟꯂꯦꯠꯀꯤ ꯂꯦꯚꯦꯜꯁꯤꯡ ꯐꯥꯎꯕ ꯊꯥꯖꯕ ꯀ꯭ꯂꯣꯖ 6.8 ꯌꯧꯒꯗꯕꯅꯤ;
- (b) ꯂꯝꯕꯤꯒꯤ ꯔꯟꯑꯣꯐ ꯑꯁꯤ ꯂꯝꯕꯤꯒꯤ ꯂꯦꯚꯦꯜꯗ ꯂꯩꯕ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯋꯣꯜꯒꯤ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯆꯡꯒꯗꯕꯅꯤ (ꯀ꯭ꯂꯣꯖ 6.6.1(b)), ꯃꯈꯣꯌ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯂꯩꯃꯨꯒꯤ ꯁꯝꯞ ꯑꯃꯥ (ꯀ꯭ꯂꯣꯖ 6.6.7) ꯂꯩꯅꯥ, ꯀ꯭ꯂꯣꯖ 6.6.4-ꯒꯤ ꯂꯥꯞ ꯊꯥꯛꯇ;
- (c) ꯐꯨꯠꯄꯥꯊꯀꯤ ꯔꯟꯑꯣꯐ ꯑꯁꯤ ꯐꯨꯠꯄꯥꯊꯇ ꯏꯁꯤꯡ ꯂꯦꯞꯄꯅꯥ ꯅꯠꯇꯅꯥ, ꯀꯚꯔꯗ ꯂꯩꯕ ꯁ꯭ꯂꯣꯠꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯒ꯭ꯔꯦꯠ ꯇꯧꯔꯕ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯆꯡꯒꯗꯕꯅꯤ; ꯑꯃꯁꯨꯡ
- (d) ꯁꯦꯡꯂꯕ ꯁꯦꯛꯁꯟ ꯑꯁꯤꯅꯥ ꯀ꯭ꯂꯣꯖ 6.7.6(c) ꯌꯧꯒꯗꯕꯅꯤ꯫
6.13.2 ꯂꯧꯊꯣꯀꯄ ꯌꯥꯕ ꯀꯚꯔꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯆꯡꯂꯛꯅꯕ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡ. ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯃꯈꯥꯒꯤꯁꯤꯡ ꯂꯩꯒꯗꯕꯅꯤ:
- (a) 10 m-ꯗꯒꯤ ꯍꯦꯟꯗꯕ ꯁꯦꯟꯇꯔꯁꯤꯡꯗ ꯂꯧꯊꯣꯀꯄ ꯌꯥꯕ ꯀꯚꯔ ꯄꯦꯅꯦꯜꯁꯤꯡ, ꯃꯈꯣꯌ ꯈꯨꯗꯤꯡꯃꯛ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 0.6 m ꯁꯥꯡꯕ ꯑꯃꯁꯨꯡ ꯁꯦꯡꯂꯕ ꯄꯥꯛꯄ ꯄꯨꯝꯕ ꯌꯧꯕ, ꯅꯦꯝꯍꯜꯂꯕ ꯂꯤꯐꯇꯤꯡ ꯄꯣꯏꯟꯠꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ, ꯊꯕꯛ ꯇꯧꯕ ꯃꯤ ꯑꯅꯤꯅꯥ ꯅꯠꯔꯒꯥ ꯈꯨꯠꯅꯥ ꯆꯂꯥꯏꯕ ꯂꯤꯐꯇꯤꯡ ꯗꯤꯚꯥꯏꯁ ꯑꯃꯅꯥ ꯂꯧꯊꯣꯀꯄ ꯌꯥꯕ, ꯑꯃꯁꯨꯡ ꯐꯨꯠꯄꯥꯊꯀꯥ ꯃꯥꯟꯅꯅꯥ ꯂꯩꯕ;
- (b) ꯖꯉ꯭ꯀꯁꯟ, ꯀꯣꯏꯕ ꯃꯐꯝ ꯑꯃꯁꯨꯡ ꯁꯦꯛꯁꯟ ꯍꯣꯡꯕ ꯃꯐꯝ ꯈꯨꯗꯤꯡꯃꯛꯇ, ꯑꯃꯁꯨꯡ ꯆꯨꯃꯊꯣꯛꯂꯕ ꯔꯟꯁꯤꯡꯗ 30 m-ꯗꯒꯤ ꯍꯦꯟꯗꯕ ꯁꯦꯟꯇꯔꯁꯤꯡꯗ ꯌꯥꯝꯗ꯭ꯔꯕꯗꯥ 0.6 m × 0.6 m-ꯒꯤ ꯁꯦꯡꯂꯕ ꯍꯥꯡꯕ ꯃꯐꯝ ꯂꯩꯕ ꯑꯦꯛꯁꯦꯁ ꯆꯦꯝꯕꯔꯁꯤꯡ; ꯑꯃꯁꯨꯡ
- (c) ꯃꯈꯣꯌꯒꯤ ꯃꯐꯝꯗ ꯂꯩꯕ ꯇ꯭ꯔꯦꯐꯤꯛ ꯅꯠꯔꯒꯥ ꯈꯣꯡꯅꯥ ꯆꯠꯄꯁꯤꯡꯒꯤ ꯂꯣꯗꯀꯤꯗꯃꯛ ꯔꯦꯇꯤꯡ ꯇꯧꯔꯕ ꯀꯚꯔꯁꯤꯡ (ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.11)꯫
6.13.3 ꯁꯤꯜꯠ ꯇ꯭ꯔꯦꯞꯁꯤꯡ. ꯀ꯭ꯂꯣꯖ 6.6.7-ꯒꯤ ꯏꯟꯂꯦꯠ ꯁꯝꯞꯁꯤꯡꯒꯤ ꯃꯊꯛꯇ, ꯁꯤꯜꯠ ꯇ꯭ꯔꯦꯞ ꯆꯦꯝꯕꯔꯁꯤꯡ ꯃꯈꯥꯒꯤ ꯃꯐꯝꯁꯤꯡꯗ ꯊꯝꯒꯗꯕꯅꯤ:
- (a) ꯑꯥꯔꯇꯤꯔꯤꯌꯦꯜ ꯂꯝꯕꯤ ꯑꯃꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯀꯜꯚꯔꯠ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯊꯛ ꯊꯡꯕ ꯃꯐꯝꯗ;
- (b) ꯄꯝꯄꯤꯡ ꯁ꯭ꯇꯦꯁꯟ ꯑꯃꯁꯨꯡ ꯗꯤꯇꯦꯟꯁꯟ ꯐꯦꯁꯤꯂꯤꯇꯤ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯃꯊꯛ ꯊꯡꯕ ꯃꯐꯝꯗ; ꯑꯃꯁꯨꯡ
- (c) ꯄꯨꯈ꯭ꯔꯤ, ꯇꯨꯔꯦꯜ ꯅꯠꯔꯒꯥ ꯑꯇꯣꯞꯄ ꯏꯁꯤꯡ ꯂꯩꯐꯝ ꯑꯃꯗ ꯂꯩꯕ ꯑꯥꯎꯠꯐꯣꯜ ꯈꯨꯗꯤꯡꯃꯛꯇ (ꯁꯔꯨꯛ 8-ꯅꯥ ꯃꯊꯧ ꯇꯥꯕ ꯒ꯭ꯔꯣꯁ ꯄꯣꯂꯨꯇꯦꯟꯠ ꯇ꯭ꯔꯦꯞꯀꯥ ꯂꯣꯌꯅꯅ)꯫
ꯁꯤꯜꯠ ꯇ꯭ꯔꯦꯞ ꯈꯨꯗꯤꯡꯃꯛ ꯑꯍꯦꯟꯕ 6B-ꯗ ꯂꯩꯕ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯌꯤꯜꯗ ꯁꯤꯖꯤꯟꯅꯗꯨꯅꯥ, ꯊꯝꯂꯕ ꯁꯦꯡꯗꯣꯀꯄꯁꯤꯡꯒꯤ ꯃꯔꯛꯇ ꯂꯥꯛꯀꯅꯤ ꯍꯥꯌꯅꯥ ꯈꯟꯕ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯊꯝꯕ ꯉꯝꯅꯕ ꯁꯥꯏꯖ ꯂꯦꯞꯀꯗꯕꯅꯤ, ꯑꯃꯁꯨꯡ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯀꯄꯒꯤ ꯒꯥꯔꯤ ꯑꯃꯅꯥ ꯌꯧꯕ ꯌꯥꯕ ꯑꯣꯏꯒꯗꯕꯅꯤ꯫
6.13.4 ꯃꯩꯍꯧꯔꯣꯟ ꯑꯃꯁꯨꯡ ꯒ꯭ꯔꯣꯁ ꯄꯣꯂꯨꯇꯦꯟꯠꯀꯤ ꯁ꯭ꯀ꯭ꯔꯤꯟꯁꯤꯡ. ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯅꯥ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟ, ꯄꯥꯏꯞ ꯅꯠꯔꯒꯥ ꯀꯜꯚꯔꯠ ꯑꯃꯗ ꯆꯡꯕ ꯃꯐꯝꯗ, ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 8-ꯒꯤ ꯃꯈꯥꯗ ꯑꯥꯎꯠꯐꯣꯜꯁꯤꯡꯗ ꯁ꯭ꯀ꯭ꯔꯤꯟꯁꯤꯡ ꯊꯝꯒꯗꯕꯅꯤ꯫ ꯁ꯭ꯀ꯭ꯔꯤꯟ ꯈꯨꯗꯤꯡꯃꯛ:
- (a) ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.8-ꯒꯤ ꯃꯈꯥꯗ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ;
- (b) ꯕꯥꯏꯄꯥꯁ ꯅꯠꯔꯒꯥ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯊꯤꯡꯂꯕ ꯁ꯭ꯀ꯭ꯔꯤꯟ ꯑꯃꯅꯥ ꯄ꯭ꯔꯣꯄꯔꯇꯤꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯂꯝꯕꯤ ꯑꯁꯤ ꯁꯔꯨꯛ ꯑꯁꯤꯒꯤ ꯂꯤꯃꯤꯠꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯄꯨꯔꯛꯂꯣꯏ; ꯑꯃꯁꯨꯡ
- (c) ꯃꯁꯤꯒꯤ ꯑꯦꯔꯤꯌꯥꯒꯤ 50% ꯊꯤꯡꯂꯕ ꯐꯤꯚꯝꯗ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯑꯣꯏꯅꯥ ꯆꯦꯛ ꯇꯧꯒꯗꯕꯅꯤ꯫
6.13.5 ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤ ꯃꯊꯛꯇ ꯕꯤꯜꯗꯤꯡ ꯁꯥꯔꯣꯏ. ꯑꯦꯞꯔꯨꯚ ꯇꯧꯔꯕ ꯀ꯭ꯔꯣꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯂꯧꯊꯣꯀꯄ ꯌꯥꯕ ꯀꯚꯔ ꯑꯃꯗꯒꯤ ꯅꯠꯇꯕ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔ ꯑꯃꯠꯇꯥ ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯒꯤ ꯃꯊꯛꯇ ꯁꯥꯔꯣꯏꯗꯕꯅꯤ꯫ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯀ꯭ꯔꯣꯁ ꯇꯧꯕ ꯗꯨꯀꯥꯅꯒꯤ ꯃꯃꯥꯡꯁꯤꯡ, ꯔꯦꯝꯞꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯈꯣꯡꯊꯥꯡꯁꯤꯡ ꯑꯁꯤ ꯂꯧꯊꯣꯀꯄ ꯌꯥꯕ ꯑꯣꯏꯒꯗꯕꯅꯤ ꯅꯠꯔꯒꯥ ꯀ꯭ꯂꯣꯖ 6.13.2 ꯌꯧꯕ ꯆꯡꯂꯛꯅꯕ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡ ꯊꯝꯒꯗꯕꯅꯤ꯫
6.13.6 ꯌꯨꯇꯤꯂꯤꯇꯤꯁꯤꯡ. ꯏꯁꯤꯡꯒꯤ ꯃꯦꯟ, ꯁꯤꯋꯔ, ꯄꯥꯋꯔ ꯅꯠꯔꯒꯥ ꯇꯦꯂꯤꯀꯣꯃꯒꯤ ꯀꯦꯕꯜ, ꯒꯦꯁ ꯄꯥꯏꯞ ꯅꯠꯔꯒꯥ ꯗꯛꯠ ꯑꯃꯠꯇꯥ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯍꯦꯛꯇꯒꯤ ꯐ꯭ꯂꯣ ꯑꯦꯔꯤꯌꯥ ꯅꯠꯔꯒꯥ ꯐ꯭ꯔꯤꯕꯣꯔꯗꯀꯤ ꯃꯅꯥꯛꯇ ꯊꯝꯂꯣꯏꯗꯕꯅꯤ, ꯅꯠꯔꯒꯥ ꯃꯗꯨꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯆꯠꯂꯣꯏꯗꯕꯅꯤ꯫ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯀ꯭ꯔꯣꯁ ꯇꯧꯒꯗꯕ ꯌꯨꯇꯤꯂꯤꯇꯤ ꯑꯃꯅꯥ:
- (a) ꯀꯚꯔꯒꯤ ꯁꯣꯐꯤꯠꯀꯤ ꯃꯊꯛꯇꯒꯤ ꯅꯠꯔꯒꯥ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯏꯟꯚꯔꯠꯀꯤ ꯃꯈꯥꯗꯒꯤ, ꯁ꯭ꯂꯤꯕ ꯑꯃꯒꯤ ꯃꯅꯨꯡꯗ ꯀ꯭ꯔꯣꯁ ꯇꯧꯒꯗꯕꯅꯤ; ꯑꯃꯁꯨꯡ
- (b) ꯃꯁꯤꯒꯤ ꯂꯦꯚꯦꯜꯒꯥ ꯂꯣꯌꯅꯅ ꯏꯔꯝꯒꯤ ꯄ꯭ꯂꯥꯟꯗ ꯎꯠꯀꯗꯕꯅꯤ꯫
ꯂꯩꯔꯤꯕ ꯌꯨꯇꯤꯂꯤꯇꯤ ꯀ꯭ꯔꯣꯁꯤꯡ ꯑꯃꯅꯥ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯑꯊꯤꯡꯕ ꯄꯤꯔꯕ ꯃꯐꯝꯗ, ꯌꯨꯇꯤꯂꯤꯇꯤ ꯑꯗꯨ ꯍꯣꯡꯗꯣꯛꯠꯔꯤꯐꯥꯎꯕ, ꯃꯁꯤꯒꯤ ꯑꯦꯔꯤꯌꯥ ꯑꯁꯤ ꯃꯁꯤꯅꯥ ꯊꯤꯡꯖꯤꯜꯂꯤꯕ ꯗꯦꯕ꯭ꯔꯤꯁꯀꯤꯗꯃꯛ 50% ꯕ꯭ꯂꯣꯀꯦꯖ ꯑꯦꯂꯥꯎꯑꯦꯟꯁꯒꯥ ꯂꯣꯌꯅꯅ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯦꯛꯁꯟꯗꯒꯤ ꯂꯧꯊꯣꯛꯀꯗꯕꯅꯤ꯫ ꯈꯣꯡꯕꯥꯟ ꯑꯗꯨ ꯑꯃꯨꯛ ꯍꯟꯅꯥ ꯁꯥꯕ ꯃꯇꯝꯗ ꯌꯨꯇꯤꯂꯤꯇꯤꯒꯤ ꯃꯄꯨꯅꯥ ꯃꯗꯨ ꯍꯣꯡꯗꯣꯛꯀꯗꯕꯅꯤ꯫
6.13.7 ꯁꯤꯋꯦꯖ. ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯗ ꯁꯤꯋꯦꯖꯒꯤ ꯀꯅꯦꯛꯁꯟ ꯑꯃꯠꯇꯥ ꯌꯥꯔꯣꯏ (ꯁꯔꯨꯛ 8)꯫ ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯁꯤꯋꯔꯁꯤꯡꯒꯤ ꯃꯅꯥꯛꯇ ꯆꯠꯂꯤꯕ ꯃꯐꯝꯁꯤꯡꯗ ꯁꯤꯜ ꯇꯧꯔꯕ ꯖꯣꯏꯟꯠꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅ ꯁꯥꯒꯗꯕꯅꯤ꯫
6.13.8 ꯃꯄꯥꯟ ꯉꯥꯛꯊꯣꯀꯄ. ꯐꯨꯠꯄꯥꯊ, ꯀꯦꯔꯤꯌꯦꯖꯋꯦ ꯅꯠꯔꯒꯥ ꯄꯕ꯭ꯂꯤꯛ ꯑꯣꯄꯟ ꯁ꯭ꯄꯦꯁ ꯑꯃꯒꯤ ꯃꯅꯥꯛꯇ ꯂꯩꯕ 1.0 m-ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯑꯏꯡꯕ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯔꯦꯂꯤꯡꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯕꯦꯔꯤꯌꯔꯁꯤꯡ ꯂꯩꯒꯗꯕꯅꯤ꯫ ꯑꯏꯡꯕ ꯀꯌꯥ ꯑꯣꯏꯔꯕꯁꯨ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯐꯨꯠꯄꯥꯊ ꯑꯃꯒꯤ ꯀꯣꯛꯅꯥ ꯀꯚꯔ ꯇꯧꯗꯅꯥ ꯊꯝꯔꯣꯏꯗꯕꯅꯤ꯫
6.13.9 ꯑꯦꯖ-ꯕꯤꯜꯠ ꯂꯦꯚꯦꯜꯁꯤꯡ. ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟ, ꯄꯥꯏꯞ ꯑꯃꯁꯨꯡ ꯃꯦꯟꯍꯣꯜ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯑꯦꯖ-ꯕꯤꯜꯠ ꯏꯟꯚꯔꯠ ꯂꯦꯚꯦꯜꯁꯤꯡ ꯑꯁꯤ ꯁꯔꯚꯦ ꯇꯧꯗꯨꯅꯥ ꯁꯕꯃꯤꯠ ꯇꯧꯒꯗꯕꯅꯤ (ꯁꯔꯨꯛ 10)꯫ ꯏꯟꯚꯔꯠꯁꯤꯡ ꯑꯁꯤ ꯗꯤꯖꯥꯏꯟꯗꯒꯤ ±15 mm-ꯒꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯒꯗꯕꯅꯤ꯫ ꯃꯁꯤꯒꯨꯝꯅꯥ ꯂꯩꯇꯕ ꯃꯐꯝꯗ HGL ꯑꯃꯨꯛ ꯍꯟꯅꯥ ꯆꯦꯛ ꯇꯧꯗꯨꯅꯥ ꯁꯕꯃꯤꯠ ꯇꯧꯒꯗꯕꯅꯤ꯫
6.13.10 ꯂꯩꯃꯨ ꯂꯧꯊꯣꯀꯄ. ꯄꯕ꯭ꯂꯤꯛ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯆꯍꯤ ꯈꯨꯗꯤꯡꯒꯤ ꯃꯣꯟꯁꯨꯟ ꯃꯇꯝ ꯍꯧꯗ꯭ꯔꯤꯉꯩꯗ, ꯁꯔꯨꯛ 10-ꯗ ꯊꯝꯂꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯛꯀꯗꯕꯅꯤ꯫
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. ꯀ꯭ꯂꯣꯖ 6.13-ꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ; ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯃꯁꯤ ꯃꯅꯤꯄꯨꯔꯒꯤ ꯄ꯭ꯔꯦꯛꯇꯤꯁꯇ ꯌꯨꯝꯐꯝ ꯑꯣꯏꯗꯨꯅꯥ ꯊꯝꯂꯤ꯫ ꯁ꯭ꯇꯦꯠ ꯑꯁꯤꯒꯤ ꯁꯍꯔꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯌꯥꯝꯅꯥ ꯐꯨꯠꯄꯥꯊꯁꯤꯡꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯀꯚꯔ ꯇꯧꯔꯕ ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯅꯤ꯫ ꯃꯈꯣꯌ ꯑꯁꯤ ꯌꯥꯝꯅꯥ ꯃꯇꯝꯗ ꯂꯦꯞꯇꯅꯥ ꯂꯩꯕ ꯀꯥꯁ꯭ꯠ-ꯏꯟ-ꯁꯤꯇꯨ ꯁ꯭ꯂꯦꯕꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯍꯥꯡꯕ ꯃꯐꯝ ꯈꯔꯈꯛꯇꯒꯥ ꯂꯣꯌꯅꯅ ꯁꯥꯏ, ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯃꯈꯣꯌ ꯁꯦꯡꯗꯣꯛꯄ ꯌꯥꯗꯦ ꯑꯃꯁꯨꯡ ꯃꯇꯝ ꯑꯃꯒꯤ ꯃꯅꯨꯡꯗ ꯂꯩꯃꯨ ꯑꯃꯁꯨꯡ ꯁꯣꯂꯤꯗ ꯋꯦꯁ꯭ꯠꯅꯥ ꯃꯄꯨꯟꯏ꯫ CPHEEO (2019)-ꯅꯥ ꯀꯚꯔ ꯇꯧꯗꯕ ꯆꯦꯅꯦꯜꯁꯤꯡ ꯑꯁꯤ "ꯃꯩꯍꯧꯔꯣꯟ ꯊꯥꯗꯣꯀꯄꯒꯤ ꯈꯨꯗꯣꯡꯆꯥꯕ ꯂꯩ" ("are prone to the dumping of garbage") ꯍꯥꯌꯅꯥ ꯅꯣꯠ ꯇꯧꯔꯤ (Part A, Ch 2), ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯀꯚꯔ ꯇꯧꯏ꯫ ꯆꯡꯂꯛꯅꯕ ꯍꯥꯡꯕ ꯃꯐꯝ ꯌꯥꯎꯗꯅꯥ ꯀꯚꯔ ꯇꯧꯕ ꯑꯁꯤꯅꯥ ꯁꯤꯡꯅꯕ ꯑꯗꯨ ꯃꯤꯠꯀꯤ ꯃꯃꯥꯡꯗꯒꯤ ꯂꯧꯊꯣꯀꯄ ꯈꯛꯇꯅꯤ꯫ NDMA (2010)-ꯅꯥ ꯃꯣꯟꯁꯨꯟ ꯃꯃꯥꯡꯒꯤ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯀꯄ ꯑꯁꯤ 31 ꯃꯥꯔꯆꯗ ꯂꯣꯏꯁꯤꯟꯒꯗꯕꯅꯤ ꯍꯥꯌꯅꯥ ꯄꯥꯎꯇꯥꯛ ꯄꯤꯔꯤ꯫ ꯃꯅꯤꯄꯨꯔꯗ ꯇꯥꯡ ꯑꯗꯨ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯑꯔꯊ ꯄꯤꯔꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ ꯅꯣꯡꯖꯨꯊꯥꯒꯤ ꯃꯇꯝ, 1 ꯑꯦꯞꯔꯤꯜꯗꯒꯤ 31 ꯑꯣꯛꯇꯣꯕꯔ ꯐꯥꯎꯕ, ꯍꯧꯕ ꯃꯇꯝꯁꯨ ꯑꯣꯏꯔꯤ꯫ ꯏꯝꯐꯥꯜꯗ ꯈꯥ-ꯅꯣꯡꯆꯨꯞ ꯃꯣꯟꯁꯨꯟꯒꯤ ꯅꯣꯔꯃꯦꯜ ꯂꯥꯛꯄꯒꯤ ꯇꯥꯡ ꯑꯁꯤ 5 ꯖꯨꯟ (ꯃꯃꯥꯡꯗ 1 ꯖꯨꯟ) ꯑꯃꯁꯨꯡ ꯍꯜꯂꯛꯄꯒꯤ ꯇꯥꯡ 15 ꯑꯣꯛꯇꯣꯕꯔꯅꯤ (1 ꯖꯨꯟ 2020-ꯗꯒꯤ ꯁꯤꯖꯤꯟꯅꯔꯤꯕ IMD-ꯒꯤ ꯅꯣꯔꯃꯦꯜꯁꯤꯡ, IMD-ꯒꯤ ꯄ꯭ꯔꯦꯁ ꯔꯤꯂꯤꯖꯗ ꯀꯣꯠꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ), ꯑꯗꯨꯕꯨ ꯅꯣꯡ ꯆꯨꯕꯒꯤ ꯊꯧꯗꯣꯛꯁꯤꯡ ꯍꯦꯟꯅꯥ ꯊꯨꯅꯥ ꯑꯃꯁꯨꯡ ꯍꯦꯟꯅꯥ ꯊꯦꯡꯅꯥ ꯂꯥꯀꯏ꯫ ꯑꯦꯞꯔꯤꯜ ꯑꯃꯁꯨꯡ ꯃꯦꯒꯤꯗꯃꯛ ꯏꯝꯐꯥꯜꯒꯤ ꯄꯨꯡ 24-ꯒꯤ ꯔꯦꯀꯣꯔꯗꯁꯤꯡ ꯑꯁꯤ 105.9 mm (16 ꯑꯦꯞꯔꯤꯜ 2004) ꯑꯃꯁꯨꯡ 122.4 mm (27 ꯃꯦ 1956)ꯅꯤ, ꯑꯃꯁꯨꯡ ꯐꯦꯕ꯭ꯔꯨꯋꯥꯔꯤꯗꯒꯤ ꯗꯤꯁꯦꯝꯕꯔ ꯐꯥꯎꯕ ꯊꯥ ꯈꯨꯗꯤꯡꯃꯛꯇ 80-ꯗꯒꯤ 160 mm-ꯒꯤ ꯄꯨꯡ 24-ꯒꯤ ꯃꯦꯛꯁꯤꯃꯝ ꯂꯩ (IMD Extremes, Imphal (Tulihal), 1953–2012); "ꯃꯥꯔꯆꯗꯒꯤ ꯑꯣꯛꯇꯣꯕꯔ ꯐꯥꯎꯕ ꯀꯟꯅꯥ ꯆꯨꯕ ꯅꯣꯡꯁꯤꯡ" ("intense rains from March to October")-ꯅꯥ ꯁꯍꯔꯒꯤ ꯂꯝꯕꯤꯁꯤꯡ ꯃꯥꯡꯍꯜꯂꯤ (AIIB, 2024); ꯑꯃꯁꯨꯡ ꯇꯝꯄꯥꯛꯀꯤ ꯅꯛꯄ ꯃꯇꯝꯒꯤ ꯃꯥꯡꯍꯟ ꯇꯥꯛꯍꯟꯈꯤꯕ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗ ꯑꯅꯤ, 28–31 ꯃꯦ 2024-ꯒꯤ ꯁꯥꯏꯛꯂꯣꯟ ꯔꯦꯃꯥꯜꯒꯤ (Cyclone Remal) ꯑꯃꯁꯨꯡ 30 ꯃꯦ–2 ꯖꯨꯟ 2025-ꯒꯤ ꯑꯗꯨ, ꯃꯣꯟꯁꯨꯟ ꯂꯥꯛꯠꯔꯤꯉꯩꯗ ꯂꯥꯛꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ)꯫ ꯃꯇꯝ ꯑꯗꯨꯒꯤ ꯃꯇꯨꯡꯗ, ꯏꯝꯐꯥꯜꯅꯥ 5 ꯑꯣꯛꯇꯣꯕꯔ 1980-ꯗ 119.4 mm ꯑꯃꯁꯨꯡ 1 ꯅꯣꯚꯦꯝꯕꯔ 1991-ꯗ 80.3 mm ꯔꯦꯀꯣꯔꯗ ꯇꯧꯈꯤ (IMD Extremes), ꯑꯃꯁꯨꯡ ꯑꯣꯛꯇꯣꯕꯔ 1992-ꯗ ꯇꯝꯄꯥꯛꯇ ꯏꯁꯤꯡ ꯏꯆꯥꯎ ꯊꯣꯛꯈꯤ (MASTEC)꯫ ꯔꯤꯁꯔꯆꯀꯤ ꯃꯇꯝꯗ ꯁꯍꯔꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯀꯄ ꯂꯣꯏꯁꯤꯟꯒꯗꯕ ꯇꯥꯡ ꯂꯩꯕ ꯑꯣꯔꯗꯔ ꯑꯃꯠꯇꯥ ꯐꯡꯈꯤꯗꯦ [TBC]꯫ ꯃꯔꯝ ꯑꯗꯨꯅꯥ ꯀ꯭ꯂꯣꯖ 6.13.10-ꯅꯥ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯑꯔꯊ ꯄꯤꯔꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ ꯃꯣꯟꯁꯨꯟ ꯃꯇꯝꯒꯤ ꯃꯇꯥꯡꯗ ꯍꯥꯌꯔꯤ, ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 10-ꯅꯥ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯁꯨꯡ ꯆꯦꯅꯦꯜꯁꯤꯡꯗ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯀꯄ ꯑꯃꯁꯨꯡ ꯏꯟꯂꯦꯠꯁꯤꯡ, ꯁꯤꯜꯠ ꯇ꯭ꯔꯦꯞꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁ꯭ꯀ꯭ꯔꯤꯟꯁꯤꯡ ꯁꯦꯡꯗꯣꯀꯄ ꯑꯁꯤ 31 ꯃꯥꯔꯆꯗ ꯂꯣꯏꯁꯤꯟꯒꯗꯕꯅꯤ ꯍꯥꯌꯅꯥ ꯃꯊꯧ ꯇꯥꯏ, ꯒꯦꯠꯁꯤꯡ, ꯐ꯭ꯂꯦꯞ ꯒꯦꯠꯁꯤꯡ, ꯄꯝꯞꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁ꯭ꯇꯦꯟꯗꯕꯥꯏ ꯄꯥꯋꯔ ꯑꯁꯤ ꯇꯥꯡ ꯑꯗꯨꯃꯛꯇ ꯁꯦꯝ ꯁꯥꯔꯦ ꯍꯥꯌꯅꯥ ꯁꯔꯇꯤꯐꯥꯏ ꯇꯧꯗꯨꯅꯥ (ꯀ꯭ꯂꯣꯖ 5.11.5 ꯑꯃꯁꯨꯡ 5.12.9); 15 ꯃꯦꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯏꯟꯂꯦꯠꯁꯤꯡ, ꯁꯤꯜꯠ ꯇ꯭ꯔꯦꯞꯁꯤꯡ, ꯁ꯭ꯀ꯭ꯔꯤꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯆꯤꯡꯒꯤ ꯁ꯭ꯇ꯭ꯔꯤꯝꯒꯤ ꯇ꯭ꯔꯦꯞꯁꯤꯡ ꯃꯇꯝꯒꯤ ꯃꯌꯥꯏꯗ ꯁꯦꯡꯗꯣꯀꯄ; 1 ꯑꯦꯞꯔꯤꯜꯗꯒꯤ 31 ꯑꯣꯛꯇꯣꯕꯔ ꯐꯥꯎꯕ ꯁ꯭ꯇꯦꯟꯗꯕꯥꯏ; ꯑꯃꯁꯨꯡ 15 ꯅꯣꯚꯦꯝꯕꯔꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯂꯩꯃꯨꯒꯤ ꯑꯏꯡꯕꯒꯤ ꯁꯔꯚꯦ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅ ꯃꯇꯝ ꯑꯗꯨꯒꯤ ꯃꯇꯨꯡꯗ ꯂꯩꯃꯨ ꯑꯃꯁꯨꯡ ꯗꯦꯕ꯭ꯔꯤꯁ ꯁꯦꯡꯗꯣꯀꯄ꯫ ꯃꯇꯝꯒꯤ ꯃꯌꯥꯏꯒꯤ ꯁꯦꯡꯗꯣꯀꯄ ꯑꯁꯤ ꯁꯦꯔꯤꯖ ꯑꯁꯤꯒꯤ ꯑꯇꯣꯞꯄ ꯅꯣꯔꯊ-ꯏꯁ꯭ꯠ ꯑꯦꯗꯤꯁꯟꯁꯤꯡꯗ ꯂꯩꯕꯒꯨꯝꯅꯥ 31 ꯃꯦꯗ ꯅꯠꯇꯅꯥ 15 ꯃꯦꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯇꯧꯒꯗꯕꯅꯤ, ꯃꯔꯝꯗꯤ 2024 ꯑꯃꯁꯨꯡ 2025-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯁꯤꯡ 28–31 ꯃꯦꯗ ꯊꯣꯛꯈꯤ, ꯑꯃꯁꯨꯡ 31 ꯃꯦꯗ ꯌꯧꯗ꯭ꯔꯤꯉꯩꯗ ꯇꯧꯒꯗꯕ ꯁꯦꯡꯗꯣꯀꯄ ꯑꯃꯥ ꯃꯈꯣꯌꯒꯤ ꯃꯇꯝꯗ ꯊꯣꯛꯀꯅꯤ꯫ ꯇꯨꯔꯦꯜꯒꯤ ꯄꯟꯁꯤꯡꯗ ꯇꯧꯕ WRD-ꯒꯤ ꯃꯁꯥꯒꯤ ꯊꯕꯛꯁꯤꯡꯅꯥ WRD-ꯒꯤ ꯀꯦꯂꯦꯟꯗꯔ ꯃꯇꯨꯡ ꯏꯟꯅꯩ꯫ ꯇꯥꯡꯁꯤꯡ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ ꯃꯅꯤꯄꯨꯔꯒꯤ ꯁꯍꯔꯁꯤꯡꯗ ꯁ꯭ꯅꯣꯒꯤ ꯐꯤꯚꯝ ꯂꯩꯇꯦ꯫
ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤ ꯃꯊꯛꯇ ꯕꯤꯜꯗꯤꯡ ꯁꯥꯕ ꯑꯁꯤ ꯕꯥꯏ-ꯂꯣꯖꯅꯥ ꯃꯃꯥꯡꯗꯒꯤ ꯊꯤꯡꯂꯤ: "ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯜ ꯈꯣꯡꯕꯥꯟ ꯅꯠꯔꯒꯥ ꯂꯝ ꯑꯃꯠꯇꯒꯤ ꯃꯊꯛꯇ ꯃꯦꯁꯟꯔꯤ ꯕꯤꯜꯗꯤꯡ ꯅꯠꯔꯒꯥ ꯁ꯭ꯇ꯭ꯔꯛꯆꯔ ꯑꯃꯠꯇꯥ ꯁꯥꯔꯣꯏꯗꯕꯅꯤ ꯅꯠꯔꯒꯥ ꯄꯥꯛꯊꯣꯛꯍꯟꯂꯣꯏꯗꯕꯅꯤ" ("Any masonry building or structure shall not be constructed or extended, over any municipal drain or land") (ꯃꯣꯗꯦꯜꯒꯤ ꯕꯥꯏ-ꯂꯣ 16 [TBC: ꯂꯣꯀꯜ ꯕꯣꯗꯤꯅꯥ ꯅꯣꯇꯤꯐꯥꯏ ꯇꯧꯔꯕ ꯕꯥꯏ-ꯂꯣꯖꯇ ꯅꯝꯕꯔ ꯑꯃꯁꯨꯡ ꯇꯦꯛꯁꯇ ꯆꯦꯛ ꯇꯧꯒꯗꯕꯅꯤ]), ꯑꯃꯁꯨꯡ "ꯃꯈꯣꯌ ꯑꯁꯤꯅꯥ ꯃꯊꯧ ꯇꯥꯕ ꯑꯣꯄꯟ ꯁ꯭ꯄꯦꯁ ꯑꯃꯠꯇꯗ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤꯗꯃꯛ ꯅꯠꯇꯕꯗꯤ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯠꯇꯥ ꯁꯥꯔꯣꯏꯗꯕꯅꯤ" ("No open drain, except for rain water, shall be constructed in any open space required by these") ꯕꯥꯏ-ꯂꯣꯖ꯫ ꯑꯗꯨꯕꯨ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡ ꯑꯁꯤ ꯂꯝ ꯈꯣꯞꯄ ꯑꯃꯁꯨꯡ ꯋꯦꯁ꯭ꯠ ꯊꯥꯗꯣꯛꯐꯝ ꯑꯣꯏꯅꯥ ꯁꯤꯖꯤꯟꯅꯔꯤ: ꯀꯩꯊꯦꯜꯒꯤ ꯋꯦꯁ꯭ꯠ ꯑꯁꯤ ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥꯗ ꯊꯥꯗꯣꯀꯏ, "ꯃꯁꯤꯅꯥ ꯆꯍꯤ ꯄꯨꯝꯕꯗ ꯆꯦꯟꯗꯕ ꯏꯁꯤꯡ ꯄꯨꯟꯁꯤꯟꯕ ꯑꯃꯥ ꯁꯦꯝꯃꯤ" ("which creates a stagnant pool all along the year") (ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ), ꯑꯃꯁꯨꯡ ꯑꯦꯞꯔꯤꯜ 2025-ꯗ ꯋꯥꯏꯁꯦꯜ ꯃꯥꯔꯤꯜ, ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥ ꯑꯃꯁꯨꯡ ꯅꯝꯕꯨꯜ ꯇꯨꯔꯦꯜꯒꯤ ꯅꯣꯡꯄꯣꯛ ꯊꯡꯕ ꯂꯩꯔꯥꯏꯒꯤ ꯃꯅꯥꯛꯇ ꯂꯩꯕ ꯂꯝ ꯈꯣꯞꯄꯁꯤꯡ ꯂꯧꯊꯣꯛꯅꯕ ꯑꯣꯔꯗꯔ ꯄꯤꯈꯤ (ꯄꯥꯎꯗ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ)꯫ ꯃꯍꯧꯁꯥꯒꯤ ꯈꯣꯡꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁꯍꯔꯒꯤ ꯆꯦꯅꯦꯜꯁꯤꯡ ꯑꯁꯤ ꯏꯔꯝꯒꯤ ꯔꯤꯖꯔꯚ (ꯀ꯭ꯂꯣꯖ 6.9) ꯂꯩꯕ ꯍꯥꯡꯗꯣꯛꯂꯕ ꯆꯦꯅꯦꯜꯁꯤꯡꯅꯤ, ꯑꯃꯁꯨꯡ ꯀꯚꯔ ꯇꯧꯕ, ꯗꯦꯛ ꯇꯧꯕ ꯅꯠꯔꯒꯥ ꯃꯈꯣꯌꯒꯤ ꯃꯊꯛꯇ ꯁꯥꯕ ꯇꯧꯔꯣꯏꯗꯕꯅꯤ꯫ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯀꯚꯔ ꯇꯧꯔꯕ ꯃꯐꯝꯗ, AIIB ꯄ꯭ꯔꯣꯖꯦꯛꯠꯀꯤ ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯨꯝꯅꯥ, ꯀ꯭ꯂꯣꯖ 6.13.2 ꯑꯁꯤ ꯃꯗꯨꯗ ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯆꯠꯅꯩ; ꯐꯨꯠꯄꯥꯊ ꯅꯠꯔꯒꯥ ꯀꯦꯔꯤꯌꯦꯖꯋꯦ ꯑꯃꯒꯤ ꯃꯅꯥꯛꯇ ꯍꯥꯡꯗꯣꯛꯅꯥ ꯂꯩꯔꯕ ꯃꯐꯝꯗ, ꯀ꯭ꯂꯣꯖ 6.13.8 ꯆꯠꯅꯩ꯫
ꯀ꯭ꯂꯣꯖ 6.13.7 ꯑꯁꯤ ꯍꯧꯖꯤꯛꯁꯨ ꯄ꯭ꯔꯦꯛꯇꯤꯁ ꯑꯣꯏꯗ꯭ꯔꯤ, ꯑꯃꯁꯨꯡ ꯃꯅꯤꯄꯨꯔꯗ ꯁꯤꯋꯔꯁꯤꯡ ꯂꯩꯔꯛꯠꯔꯤꯐꯥꯎꯕ ꯑꯣꯏꯕ ꯉꯝꯂꯣꯏ꯫ ꯖꯨꯟ 2020-ꯗ ꯀꯃꯤꯁꯟ ꯇꯧꯈꯤꯕ ꯏꯝꯐꯥꯜꯒꯤ ꯁꯤꯋꯔꯦꯖ ꯐꯦꯖ I-ꯅꯥ IMC-ꯒꯤ ꯋꯥꯔꯗ 27-ꯒꯤ ꯃꯅꯨꯡꯗ 11 ꯌꯥꯎꯏ, ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯋꯥꯔꯗ 16 ꯑꯃꯁꯨꯡ ꯑꯥꯎꯇꯒ꯭ꯔꯣꯊ ꯃꯔꯤꯒꯤꯗꯃꯛ ꯐꯦꯖ II ꯄ꯭ꯂꯥꯟ ꯇꯧꯔꯤ (ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟ); ꯌꯨꯝꯒꯤ ꯀꯅꯦꯛꯁꯟꯁꯤꯡ ꯇꯥꯔꯒꯦꯠ ꯇꯧꯈꯤꯕ 51,754-ꯒꯤ ꯃꯅꯨꯡꯗ 8,600-ꯗꯒꯤ 8,700 ꯐꯥꯎꯕ ꯂꯩꯈꯤ, ꯑꯃꯁꯨꯡ "ꯁꯍꯔꯒꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯗ ꯁꯤꯋꯦꯖ ꯊꯣꯀꯄ ꯑꯁꯤ 70 MLD-ꯅꯤ ꯑꯃꯁꯨꯡ ꯂꯩꯔꯤꯕ ꯇ꯭ꯔꯤꯠꯃꯦꯟꯠ ꯐꯦꯁꯤꯂꯤꯇꯤꯁꯤꯡ ꯑꯁꯤ 44 MLD-ꯅꯤ" ("Sewage generation in urban areas is 70 MLD and existing treatment facilities are 44 MLD") (NGT-ꯗ ꯁ꯭ꯇꯦꯠꯀꯤ ꯔꯤꯄꯣꯔꯠ, ꯖꯨꯂꯥꯏ 2025)꯫ ꯑꯇꯣꯞꯄ ꯃꯐꯝꯁꯤꯡꯗ ꯁꯦꯞꯇꯤꯛ ꯇꯦꯉ꯭ꯛꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁꯣꯛ ꯄꯤꯠꯁꯤꯡ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯊꯟꯊꯣꯀꯏ, ꯑꯃꯁꯨꯡ "ꯃꯅꯤꯄꯨꯔꯒꯤ ꯆꯤꯡꯒꯤ ꯂꯝꯁꯤꯡꯗ ꯁꯦꯞꯇꯤꯛ ꯇꯦꯉ꯭ꯛꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇ꯭ꯕꯤꯟ ꯁꯣꯛ ꯄꯤꯠꯁꯤꯡꯗ ꯍꯧꯖꯤꯛ ꯊꯥꯖꯕ ꯊꯝꯂꯤꯕ ꯑꯁꯤ ꯃꯥꯟꯅꯩ" ("The existing reliance on septic tanks and twin soak pits in the hilly regions of Manipur is appropriate") (ꯔꯤꯄꯣꯔꯠ ꯑꯗꯨꯃꯛ)꯫ ꯅꯝꯕꯨꯜ ꯇꯨꯔꯦꯜꯗ ꯆꯦꯟꯊꯔꯀꯄ ꯈꯣꯡꯕꯥꯟ 72-ꯅꯥ BOD 42.45-ꯗꯒꯤ 52.34 mg/L ꯄꯨꯏ, ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌꯒꯤ ꯏꯟꯇꯔꯁꯦꯞꯁꯟ ꯑꯃꯁꯨꯡ ꯗꯥꯏꯚꯔꯁꯟ ꯑꯁꯤ ꯂꯣꯏꯔꯦ ꯍꯥꯌꯅꯥ ꯔꯤꯄꯣꯔꯠ ꯇꯧꯔꯤ (NGT-ꯗ ꯁ꯭ꯇꯦꯠꯀꯤ ꯔꯤꯄꯣꯔꯠ, ꯗꯤꯁꯦꯝꯕꯔ 2025)꯫ ꯀ꯭ꯂꯣꯖ 6.3.6(a)-ꯗꯒꯤ (e) ꯐꯥꯎꯕ ꯑꯁꯤꯅꯥ ꯃꯔꯛ ꯑꯁꯤꯗ ꯁꯤꯋꯦꯖ ꯄꯨꯕ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯥ ꯀꯔꯝꯅꯥ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯒꯦ ꯍꯥꯌꯕꯗꯨ ꯊꯝꯂꯤ, ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖ 8.9-ꯅꯥ ꯀꯅꯦꯛꯁꯟꯁꯤꯡ ꯂꯧꯊꯣꯛꯠꯔꯤꯐꯥꯎꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯗ ꯂꯩꯕ ꯅꯣꯡ ꯆꯨꯗꯕ ꯃꯇꯝꯒꯤ ꯆꯦꯟꯕ ꯑꯁꯤ ꯀꯔꯝꯅꯥ ꯁꯔꯚꯦ ꯇꯧꯒꯗꯒꯦ ꯑꯃꯁꯨꯡ ꯏꯟꯇꯔꯁꯦꯞꯇ ꯇꯧꯒꯗꯒꯦ ꯍꯥꯌꯕꯗꯨ ꯊꯝꯂꯤ, ꯏꯟꯇꯔꯁꯦꯞꯁꯟꯅꯥ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯍꯟꯊꯍꯜꯂꯣꯏꯗꯕꯅꯤ ꯍꯥꯌꯕ ꯔꯨꯜ ꯌꯥꯑꯣꯅꯥ (ꯀ꯭ꯂꯣꯖ 8.9.5(b))꯫
10 m ꯑꯃꯁꯨꯡ 30 m-ꯒꯤ ꯂꯥꯞ ꯊꯥꯛꯁꯤꯡ ꯑꯃꯁꯨꯡ ±15 mm-ꯒꯤ ꯇꯣꯂꯔꯦꯟꯁ ꯑꯁꯤꯒꯤ ꯍꯛꯊꯦꯡꯅꯕ ꯃꯃꯥꯡꯒꯤ ꯈꯨꯗꯝ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌ ꯑꯁꯤ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯅꯥ ꯊꯝꯕꯅꯤ꯫ ꯀ꯭ꯂꯣꯖ 6.13.6-ꯅꯥ ꯏꯁꯤꯡꯒꯤ ꯃꯦꯟꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯀꯦꯕꯜꯁꯤꯡ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯆꯠꯂꯤꯕ ꯃꯇꯝ ꯄꯨꯝꯕꯗ ꯎꯕ ꯐꯤꯚꯝ ꯑꯗꯨꯒꯤ ꯄꯥꯎꯈꯨꯝ ꯄꯤꯔꯤ꯫ ꯃꯈꯣꯌ ꯈꯨꯗꯤꯡꯃꯛꯅꯥ ꯗꯦꯕ꯭ꯔꯤꯁ ꯊꯤꯡꯖꯤꯜꯂꯤ ꯑꯃꯁꯨꯡ ꯁꯦꯛꯁꯟ ꯍꯟꯊꯍꯜꯂꯤ꯫ ꯃꯅꯨꯡꯗ ꯃꯤꯑꯣꯏ ꯆꯡꯕꯒꯤ ꯃꯍꯨꯠꯇ ꯀꯚꯔꯒꯤ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡꯒꯤ ꯈꯨꯠꯊꯥꯡꯗ ꯃꯦꯀꯥꯅꯤꯀꯦꯜ ꯑꯣꯏꯅꯥ ꯁꯦꯡꯗꯣꯀꯄ ꯑꯁꯤ ꯃꯐꯝ ꯄꯨꯝꯕꯗ ꯂꯧꯏ, ꯄ꯭ꯔꯣꯍꯤꯕꯤꯁꯟ ꯑꯣꯐ ꯏꯃꯞꯂꯣꯏꯃꯦꯟꯠ ꯑꯦꯖ ꯃꯦꯅꯨꯌꯦꯜ ꯁ꯭ꯀꯦꯚꯦꯟꯖꯔꯁ ꯑꯃꯁꯨꯡ ꯊꯦꯌꯔ ꯔꯤꯍꯦꯕꯤꯂꯤꯇꯦꯁꯟ ꯑꯦꯛꯠ, 2013 (Prohibition of Employment as Manual Scavengers and their Rehabilitation Act, 2013)-ꯒꯥ ꯃꯥꯟꯅꯅꯥ꯫
6.14 ꯑꯥꯎꯠꯐꯣꯜꯁꯤꯡ
6.14.1 ꯑꯥꯎꯠꯐꯣꯜꯁꯤꯡ ꯑꯁꯤ ꯁꯔꯨꯛ 5-ꯒꯤ ꯇꯦꯜꯋꯥꯇꯔꯒꯤ ꯐꯤꯚꯝꯁꯤꯡꯒꯤꯗꯃꯛ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ꯫ 1% AEP-ꯒꯤ ꯁ꯭ꯇꯤꯜ-ꯋꯥꯇꯔ ꯂꯦꯚꯦꯜꯒꯤ ꯃꯈꯥꯗ ꯂꯩꯕ ꯑꯥꯎꯠꯐꯣꯜꯁꯤꯡꯗ ꯐ꯭ꯂꯦꯞ ꯅꯠꯔꯒꯥ ꯇꯥꯏꯗ ꯒꯦꯠꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯅꯟ-ꯔꯤꯇꯔꯟ ꯚꯥꯜꯚꯁꯤꯡ ꯂꯩꯒꯗꯕꯅꯤ (ꯁꯔꯨꯛ 5 ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.10)꯫
6.14.2 ꯑꯥꯎꯠꯐꯣꯜ ꯉꯥꯛꯊꯣꯀꯄ ꯑꯃꯁꯨꯡ ꯑꯦꯅꯔꯖꯤ ꯗꯤꯁꯤꯄꯦꯁꯟ ꯑꯁꯤ ꯁꯔꯨꯛ 9, ꯀ꯭ꯂꯣꯖ 9.6-ꯒꯤ ꯃꯈꯥꯗ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯒꯗꯕꯅꯤ꯫ ꯄꯨꯈ꯭ꯔꯤꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡ ꯂꯩꯐꯝꯁꯤꯡꯗ ꯂꯩꯕ ꯑꯥꯎꯠꯐꯣꯜꯁꯤꯡꯅꯥ ꯁꯔꯨꯛ 7 ꯑꯃꯁꯨꯡ 8-ꯁꯨ ꯌꯧꯒꯗꯕꯅꯤ꯫
6.15 ꯁꯕꯃꯤꯇꯦꯜꯒꯤ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡ
ꯀꯟꯚꯦꯌꯦꯟꯁꯀꯤ ꯁꯕꯃꯤꯇꯦꯜ ꯈꯨꯗꯤꯡꯃꯛꯇ ꯃꯈꯥꯒꯤꯁꯤꯡ ꯌꯥꯎꯕ ꯀꯟꯚꯦꯌꯦꯟꯁ ꯗꯤꯖꯥꯏꯟ ꯔꯤꯄꯣꯔꯠ (Conveyance Design Report) (ꯐꯣꯔꯝ 6-1) ꯑꯃꯥ ꯌꯥꯎꯒꯗꯕꯅꯤ:
- 1% AEP-ꯒꯤ ꯏꯚꯦꯟꯠꯀꯤꯗꯃꯛ ꯁꯕ-ꯀꯦꯆꯃꯦꯟꯠꯁꯤꯡ, ꯃꯥꯏꯅꯔ ꯁꯤꯁ꯭ꯇꯦꯝ, ꯏꯟꯂꯦꯠꯀꯤ ꯃꯐꯝꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯃꯦꯖꯔ-ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯑꯣꯚꯔꯂꯦꯟꯗ ꯐ꯭ꯂꯣ ꯂꯝꯕꯤꯁꯤꯡ ꯎꯠꯄ ꯀꯦꯆꯃꯦꯟꯠ ꯄ꯭ꯂꯥꯟ ꯑꯃꯥ (ꯀ꯭ꯂꯣꯖ 6.3.2);
- ꯑꯦꯂꯤꯃꯦꯟꯠ ꯈꯨꯗꯤꯡꯃꯛꯀꯤꯗꯃꯛ ꯂꯧꯈꯤꯕ ꯂꯝ ꯁꯤꯖꯤꯟꯅꯕ ꯑꯃꯁꯨꯡ ꯂꯝꯕꯤꯒꯤ ꯀ꯭ꯂꯥꯁꯀꯤ AEP (ꯇꯦꯕꯜ 6.1), ꯑꯃꯁꯨꯡ ꯍꯥꯏ-ꯗꯦꯟꯁꯤꯇꯤ ꯑꯦꯔꯤꯌꯥꯒꯤ ꯁ꯭ꯇꯦꯇꯁ;
- ꯁꯔꯨꯛ 2-ꯒꯤ ꯅꯣꯡ ꯆꯨꯕꯒꯤ ꯁꯤꯠ ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 3-ꯒꯤ ꯊꯧꯑꯣꯡꯒꯥ ꯂꯣꯌꯅꯅ ꯗꯤꯖꯥꯏꯟ ꯐ꯭ꯂꯣꯁꯤꯡ;
- ꯃꯥꯏꯅꯔ, ꯆꯦꯛ ꯑꯃꯁꯨꯡ 1%-ꯒꯤ ꯏꯚꯦꯟꯠꯁꯤꯡꯒꯤꯗꯃꯛ ꯒꯇꯔꯒꯤ ꯁ꯭ꯞꯔꯦꯗ, ꯑꯏꯡꯕ ꯑꯃꯁꯨꯡ D·V-ꯒꯤ ꯆꯦꯛꯁꯤꯡ (ꯇꯦꯕꯜ 6.2 ꯑꯃꯁꯨꯡ 6.3);
- ꯁꯦꯡꯂꯕ ꯀꯦꯄꯥꯁꯤꯇꯤ, ꯀꯨꯞꯄꯒꯤ ꯐꯦꯛꯇꯔ, ꯗꯤꯖꯥꯏꯟ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯑꯃꯁꯨꯡ ꯕꯥꯏꯄꯥꯁ ꯐ꯭ꯂꯣꯒꯥ ꯂꯣꯌꯅꯅ ꯏꯟꯂꯦꯠꯀꯤ ꯁꯦꯗ꯭ꯌꯨꯜ ꯑꯃꯥ (ꯀ꯭ꯂꯣꯖ 6.6);
- n, ꯚꯦꯂꯣꯁꯤꯇꯤ, ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁ ꯑꯃꯁꯨꯡ ꯐ꯭ꯔꯤꯕꯣꯔꯗꯒꯥ ꯂꯣꯌꯅꯅ ꯄꯥꯏꯞ ꯑꯃꯁꯨꯡ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯇꯦꯕꯜꯁꯤꯡ (ꯀ꯭ꯂꯣꯖ 6.7);
- ꯁꯤꯖꯤꯟꯅꯈꯤꯕ ꯇꯦꯜꯋꯥꯇꯔꯒꯥ ꯂꯣꯌꯅꯅ ꯃꯥꯏꯅꯔ ꯑꯃꯁꯨꯡ ꯆꯦꯛ ꯏꯚꯦꯟꯠꯁꯤꯡꯒꯤꯗꯃꯛ HGL ꯄ꯭ꯔꯣꯐꯥꯏꯜꯁꯤꯡ (ꯀ꯭ꯂꯣꯖ 6.8);
- ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯊꯤꯡꯂꯕ ꯐꯤꯚꯝꯒꯤ ꯆꯦꯛ ꯌꯥꯑꯣꯅꯥ ꯁꯦꯒꯇ ꯏꯁꯤꯡ ꯂꯦꯞꯄꯒꯤ ꯂꯦꯚꯦꯜꯁꯤꯡ (ꯀ꯭ꯂꯣꯖ 6.10);
- ꯕꯤꯜꯗꯤꯡ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯐ꯭ꯂꯣꯔ-ꯂꯦꯚꯦꯜꯒꯤ ꯁꯦꯗ꯭ꯌꯨꯜ ꯑꯃꯥ (ꯀ꯭ꯂꯣꯖ 6.11);
- ꯀꯜꯚꯔꯠ ꯑꯃꯁꯨꯡ ꯀ꯭ꯔꯣꯁꯤꯡꯒꯤ ꯀꯦꯜꯀꯨꯂꯦꯁꯟꯁꯤꯡ (ꯀ꯭ꯂꯣꯖ 6.12 ꯑꯃꯁꯨꯡ ꯁꯔꯨꯛ 9); ꯑꯃꯁꯨꯡ
- ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤꯗꯃꯛ ꯌꯨꯇꯤꯂꯤꯇꯤ-ꯀ꯭ꯔꯣꯁꯤꯡꯒꯤ ꯁꯦꯗ꯭ꯌꯨꯜ ꯑꯃꯁꯨꯡ ꯆꯡꯂꯛꯅꯕ ꯍꯥꯡꯕ ꯃꯐꯝꯁꯤꯡꯒꯤ ꯂꯦꯑꯥꯎꯠ (ꯀ꯭ꯂꯣꯖ 6.13)꯫
ꯂꯧꯔꯛꯐꯝꯁꯤꯡ (ꯁꯔꯨꯛ)
- MoHUA / CPHEEO (2019). Manual on Storm Water Drainage Systems, Volume I, Part A: Engineering Design. Tables 4.1, 5.1, 5.2, 5.3, 5.8, 5.11, 5.12, 6.2, 11.2, 11.5; §5.3, §5.6.2, Fig. 5.9. https://www.mohua.gov.in/static/uploads/2025/10/8a2456c722036d78c72a698898ef846d.pdf
- PUB Singapore (2018, Addendum No. 3, ꯑꯦꯞꯔꯤꯜ 2025-ꯒꯥ ꯂꯣꯌꯅꯅ). Code of Practice on Surface Water Drainage, 7th edition. Clauses 1.1, 2.1.1, 5.1, 5.3, 9.6, 9.7 and Appendix 1 (Drainage Reserve Requirements). https://www.pub.gov.sg/-/media/PUB/PDF/Code-of-Practices-and-Submission-Guidelines/Surface-Water-Drainage/Code-of-Practice-on-Surface-Water-Drainage.pdf
- Indian Roads Congress (2013). IRC:SP:50-2013, Guidelines on Urban Drainage (First Revision). https://law.resource.org/pub/in/bis/irc/irc.gov.in.sp.050.2013.pdf
- Indian Roads Congress (2014). IRC:SP:42-2014, Guidelines on Road Drainage (First Revision). https://law.resource.org/pub/in/bis/irc/irc.gov.in.sp.042.2014.pdf
- Bureau of Indian Standards. IS 7784 (Part 1): 1993, Code of practice for design of cross drainage works, Part 1: General features (CPHEEO 2019 Table 5.12-ꯗ ꯀꯣꯠꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ)꯫
- Federal Highway Administration (2024). Urban Drainage Design Manual, Hydraulic Engineering Circular No. 22, 4th edition, FHWA-HIF-24-006. (3rd edition 2009, FHWA-NHI-10-009.)
- Kansas City Metro Chapter APWA (2006). Section 5600 Storm Drainage Systems and Facilities (5601.8, 5604.2, 5608.4). https://www.kcwater.us/wp-content/uploads/2020/08/Design-Criteria-%E2%80%93-Section-5600-%E2%80%93-Storm-Drainage-Systems-and-Facilities.pdf ; ꯑꯃꯁꯨꯡ Version 2025.01 (Dec 2025).
- Australian Institute for Disaster Resilience (2014). Australian Disaster Resilience Guideline 7-3: Technical flood risk management guideline: Flood hazard. Tables 1 and 2. https://knowledge.aidr.org.au/media/1891/guideline-7-3-technical-flood-risk-management.pdf
- Smith, G.P. and Wasko, C.D. (2012). Australian Rainfall and Runoff Revision Project 15: Two-dimensional modelling in urban and rural floodplains. Engineers Australia.
- Ball, J. et al. (eds) (2019). Australian Rainfall and Runoff: A Guide to Flood Estimation, Book 6 (Chapters 6 and 7). Commonwealth of Australia (Geoscience Australia).
- Department of Irrigation and Drainage Malaysia (2008). Submission Checklist for Stormwater Management; ꯑꯃꯁꯨꯡ (2012) Urban Stormwater Management Manual for Malaysia (MSMA), 2nd edition.
- Gupta, K. Return Period and Rainfall Intensity for Drainage Design in India. IIT Bombay. https://www.civil.iitb.ac.in/~kgupta/drainagedesign.pdf
- Asian Infrastructure Investment Bank (2024). Approval Project Document (ꯑꯣꯛꯇꯣꯕꯔ 2024) and Project Summary Information (29 ꯅꯣꯚꯦꯝꯕꯔ 2024), Manipur Urban Road, Drainage and Asset Management Improvement Project (P000723) (ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡꯒꯤ ꯐꯤꯚꯝ; ꯀꯚꯔ ꯇꯧꯔꯕ ꯈꯣꯡꯕꯥꯟ 547 km; "intense rains from March to October"; ꯂꯝꯕꯤꯗ ꯏꯁꯤꯡ ꯏꯆꯥꯎꯒꯤ ꯏꯟꯗꯤꯀꯦꯇꯔ), https://aiib.org/en/projects/details/2024/_download/India/AIIB-APD_P000723_Manipur-Urban-Road-Drainage-and-Asset-Management-Improvement-Project.pdf ꯑꯃꯁꯨꯡ https://www.aiib.org/en/projects/details/2024/_download/India/AIIB-PSI-P000723-India-Manipur-Urban-Road-Drainage-and-Asset-Management-Improvement-Project_clean_20241129.pdf ; ꯑꯃꯁꯨꯡ ꯃꯁꯤꯒꯤ IEE annexure (ꯃꯍꯧꯁꯥꯒꯤ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯦꯛꯁꯟꯁꯤꯡ, ꯑꯥꯎꯠꯂꯦꯠꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯋꯤꯞ ꯄꯥꯏꯞꯁꯤꯡ; ꯇꯦꯛꯁꯇ ꯈꯛꯇꯃꯛ ꯊꯤꯈꯤꯕ), https://www.aiib.org/en/projects/details/2024/_download/India/Annexure-IEE.pdf
- Municipal Administration, Housing and Urban Development Department, Government of Manipur. Revised GIS Based Master Plan for Greater Imphal – 2043 (1st Modification), No. SCS-401/3/2021-MAHUD-MAHUD-Part(3), 4 ꯗꯤꯁꯦꯝꯕꯔ 2024-ꯒꯤ (ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯏꯔꯝꯒꯤ ꯁꯦꯛꯁꯟ ꯂꯩꯇꯦ; ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥ; ꯏꯝꯐꯥꯜ ꯁꯤꯋꯔꯦꯖ ꯄ꯭ꯔꯣꯖꯦꯛꯠ), https://tpmanipur.mn.gov.in/media/filer_public/81/1c/811cef92-cba3-43cb-9e7f-caeef3738b68/revised_imphal_master_plan_report-1st_modification.pdf
- Government of Manipur. "Updated Fresh Report" in NGT O.A. 606/2018 (ꯖꯨꯂꯥꯏ 2025) (ꯁꯤꯋꯦꯖ ꯊꯣꯀꯄ ꯑꯃꯁꯨꯡ ꯇ꯭ꯔꯤꯠꯃꯦꯟꯠ; ꯌꯨꯝꯒꯤ ꯀꯅꯦꯛꯁꯟꯁꯤꯡ; ꯆꯤꯡꯁꯤꯡꯗ ꯁꯦꯞꯇꯤꯛ ꯇꯦꯉ꯭ꯛꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇ꯭ꯕꯤꯟ ꯄꯤꯠꯁꯤꯡ), https://www.greentribunal.gov.in/sites/default/files/news_updates/UPDATED%20REPORT%20BY%20GOVT.%20OF%20MANUPUR%20IN%20OA%20NO.%20606%20of%202018%20(COMPLIANCE%20OF%20MSW%20MGT.%20RULES,%202016%20AND%20OTHER%20ENVIRONMENTAL%20ISSUES).pdf ; ꯑꯃꯁꯨꯡ ꯇꯔꯨꯛꯁꯨꯕ six-monthly progress report (ꯗꯤꯁꯦꯝꯕꯔ 2025 ꯐꯥꯑꯣꯕ) (ꯅꯝꯕꯨꯜ ꯇꯨꯔꯦꯜꯗ ꯆꯦꯟꯊꯔꯀꯄ ꯈꯣꯡꯕꯥꯟ 72 ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌꯒꯤ BOD ꯑꯃꯁꯨꯡ COD), https://www.greentribunal.gov.in/sites/default/files/news_updates/6TH%20SIX%20MONTHLY%20PROGRESS%20REPORT%20BY%20GOVT.%20OF%20MANIPUR%20IN%20OA%20NO.%20606%20of%202018%20(COMPLIANCE%20OF%20MSW%20MGT%20RULES,%202016%20AND%20OTHER%20ENVIRONMENTAL%20ISSUES).pdf
- Central Pollution Control Board (2025). Polluted River Stretches for Restoration of Water Quality (ꯃꯅꯤꯄꯨꯔꯗ ꯂꯩꯕ Priority V-ꯒꯤ ꯔꯤꯆ 18), https://dste.py.gov.in/ppcc/pdf/Laboratory/PRS-2025.pdf
- Town Planning Department, Government of Manipur. Annual Administrative Report 2025-26 (ꯂꯣꯀꯦꯜ ꯑꯦꯔꯤꯌꯥ ꯄ꯭ꯂꯥꯟꯒꯤ ꯁꯥꯏꯠ ꯑꯣꯏꯅꯥ ꯏꯝꯐꯥꯜꯒꯤ ꯃꯌꯥꯏꯒꯤ ꯑꯦꯔꯤꯌꯥ ꯑꯃꯁꯨꯡ ꯂꯝꯐꯦꯜꯄꯥꯠ ꯑꯦꯔꯤꯌꯥ; AMRUT 2.0-ꯒꯤ ꯄꯣꯟꯗ ꯄ꯭ꯔꯣꯖꯦꯛꯠꯁꯤꯡ), https://www.tpmanipur.mn.gov.in/media/filer_public/1a/48/1a484b87-afaa-41de-8d64-f6d2f27c49c7/admn_report2025-26.pdf
- Manipur Science & Technology Council (MASTEC). Flood Hazard Zonation in Manipur Valley, DST-NRDMS-ꯗ ꯄꯤꯈꯤꯕ ꯐꯥꯏꯅꯦꯜ ꯔꯤꯄꯣꯔꯠ (ꯗꯤꯁꯥꯡ ꯁꯦꯜ; ꯏꯔꯣꯖꯟ ꯑꯃꯁꯨꯡ ꯐꯠꯇꯕ ꯑꯣꯏꯔꯕ ꯂꯝ; ꯆꯤꯡꯒꯤ ꯁ꯭ꯇ꯭ꯔꯤꯝꯁꯤꯡꯅꯥ ꯂꯣꯛꯇꯥꯛꯇ ꯂꯩꯃꯨ ꯊꯨꯗꯣꯀꯄ; ꯑꯣꯛꯇꯣꯕꯔ 1992-ꯒꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎ), http://web.archive.org/web/20180219013113id_/http://mastec.nic.in:80/images/Completed_projects/ReportFloodHazard.pdf
- National Disaster Management Authority (2010) (ꯃꯣꯟꯁꯨꯟ ꯃꯃꯥꯡꯒꯤ ꯂꯩꯃꯨ ꯂꯧꯊꯣꯀꯄꯒꯤꯗꯃꯛ 31 ꯃꯥꯔꯆ, ꯁꯔꯨꯛ 10-ꯗ ꯀꯣꯠꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ); India Meteorological Department, Extremes of Temperature and Rainfall for Indian Stations (up to 2012) (Imphal (Tulihal)), https://imdpune.gov.in/library/public/EXTREMES%20OF%20TEMPERATURE%20and%20RAINFALL%20upto%202012.pdf ; ꯑꯃꯁꯨꯡ India Meteorological Department, ꯈꯥ-ꯅꯣꯡꯆꯨꯞ ꯃꯣꯟꯁꯨꯟꯒꯤ ꯂꯥꯛꯄ ꯑꯃꯁꯨꯡ ꯍꯜꯂꯛꯄꯒꯤ ꯑꯅꯧꯕ ꯅꯣꯔꯃꯦꯜ ꯇꯥꯡꯁꯤꯡꯒꯤ ꯃꯇꯥꯡꯗ ꯄ꯭ꯔꯦꯁ ꯔꯤꯂꯤꯖ (2020), https://mausam.imd.gov.in/backend/assets/press_release_pdf/IMD_Press_release_new_onset_and_withdrawal_dates%28Final%29.pdf (ꯀꯣꯠꯈꯤꯕ ꯃꯇꯨꯡ ꯏꯟꯅ)꯫
- Indian Roads Congress (1998). IRC:SP:48-1998, Hill Road Manual (ꯏꯔꯝꯒꯤ ꯄ꯭ꯔꯣꯚꯤꯖꯟꯁꯤꯡ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤꯗꯃꯛ ꯄꯥꯈꯤꯗꯕ); ꯑꯃꯁꯨꯡ IRC:SP:42-2014, cl. 7.1.4 (ꯂꯝꯕꯤꯒꯤ ꯈꯣꯡꯕꯥꯟ ꯑꯃꯁꯨꯡ ꯀꯜꯚꯔꯠꯁꯤꯡꯒꯤ ꯗꯤꯖꯥꯏꯟ ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗꯁꯤꯡ) ꯑꯃꯁꯨꯡ cl. 8.5.1 (ꯆꯤꯡꯒꯤ ꯂꯝꯕꯤꯁꯤꯡꯒꯤ ꯏꯔꯝ)꯫
- Bureau of Indian Standards. IS 14458, Guidelines for retaining wall for hill area (Parts 1–3), ꯃꯣꯗꯦꯜ ꯕꯥꯏ-ꯂꯣꯖꯅꯥ ꯔꯦꯐꯔ ꯇꯧꯔꯕ ꯃꯑꯣꯡꯗ꯫
- Press reports: ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥ ꯑꯃꯁꯨꯡ ꯋꯥꯏꯁꯦꯜ ꯃꯥꯔꯤꯜ (2024–2025), 2024 ꯑꯃꯁꯨꯡ 2025-ꯒꯤ ꯄꯟ ꯀꯛꯄꯁꯤꯡ, 30 ꯖꯨꯟ 2022-ꯒꯤ ꯇꯨꯄꯨꯜ (ꯅꯣꯅꯦ) ꯂꯦꯟꯗꯁ꯭ꯂꯥꯏꯗ ꯑꯃꯁꯨꯡ 1 ꯑꯒꯁ꯭ꯠ 2015-ꯒꯤ ꯖꯧꯃꯣꯜ (ꯆꯥꯟꯗꯦꯜ) ꯂꯦꯟꯗꯁ꯭ꯂꯥꯏꯗ, ꯁ꯭ꯃꯥꯔꯠ ꯁꯤꯇꯤꯒꯤ ꯑꯦꯔꯤꯌꯥ-ꯕꯦꯖ ꯗꯦꯚꯦꯂꯞꯃꯦꯟꯠ ꯑꯦꯔꯤꯌꯥ, 15 ꯖꯨꯂꯥꯏ 2025-ꯒꯤ ꯈꯧꯄꯨꯝ ꯇꯝꯄꯥꯛꯀꯤ ꯏꯁꯤꯡ ꯏꯆꯥꯎ, ꯑꯃꯁꯨꯡ ꯋꯥꯏꯁꯦꯜ ꯃꯥꯔꯤꯜꯗ LDA-ꯒꯤ ꯊꯕꯛꯀꯤ ꯃꯇꯥꯡꯗ꯫
- National Disaster Management Authority (2010). National Guidelines: Management of Urban Flooding.
- MoHUA / TCPO (2015). URDPFI Guidelines, Volume I.
- Ministry of Environment, Forest and Climate Change (2019). Coastal Regulation Zone Notification, 2019, G.S.R. 37(E), 18 ꯖꯥꯅꯨꯋꯥꯔꯤ 2019. Para 1(i) and Annexure IV. https://crz.elaw.in/crz2019.html
- Municipal Administration, Housing and Urban Development Department, Government of Manipur. The Model Manipur Unified Building Bye-Laws, 2024, Notification No. BBL-101/1/2024-MAHUD-MAHUD-Part(1), 4 ꯗꯤꯁꯦꯝꯕꯔ 2024-ꯒꯤ, Manipur Gazette Extraordinary No. 253, 5 ꯗꯤꯁꯦꯝꯕꯔ 2024-ꯒꯤ, ꯃꯅꯤꯄꯨꯔ ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯂꯤꯇꯤꯖ ꯑꯦꯛꯠ, 1994-ꯒꯤ ꯁꯦꯛꯁꯟ 213 ꯑꯃꯁꯨꯡ ꯃꯅꯤꯄꯨꯔ ꯇꯥꯎꯟ ꯑꯃꯁꯨꯡ ꯀꯟꯇ꯭ꯔꯤ ꯄ꯭ꯂꯥꯅꯤꯡ ꯑꯦꯛꯠ, 1975-ꯒꯤ ꯁꯦꯛꯁꯟ 26(1)-ꯒꯤ ꯃꯈꯥꯗ "for adoption by the Urban Local Bodies and Planning & Development Authority, Manipur" ꯐꯣꯡꯗꯣꯛꯈꯤꯕ (ꯕꯥꯏ-ꯂꯣ 6(1)(A), 6(1)(D), 16, 27, 28, 92, 93 ꯑꯃꯁꯨꯡ 94; IS 14458), https://www.tpmanipur.mn.gov.in/media/filer_public/5b/3d/5b3d9440-3e85-4cf5-bd26-d113882dfb9a/model_manipur_ubbl_final_gazette.pdf
- Imphal Municipal Corporation Building Bye-Laws (3rd Amendment), 2024 (ꯑꯣꯕꯖꯦꯛꯁꯟꯁꯤꯡꯒꯤꯗꯃꯛ ꯐꯣꯡꯗꯣꯛꯈꯤꯕ ꯗ꯭ꯔꯥꯐꯠ ꯇꯦꯛꯁꯠ; ꯕꯥꯏ-ꯂꯣ 92, 92.1, 92.2, 93.1 ꯑꯃꯁꯨꯡ 93.2; ꯑꯔꯣꯏꯕ ꯁ꯭ꯇꯦꯇꯁ ꯀꯟꯐꯥꯔꯝ ꯇꯧꯈꯤꯗꯦ), https://www.tpmanipur.mn.gov.in/media/filer_public/22/ef/22ef77df-5b8c-4a80-9fa0-553d8a60a170/amendment_of_imc_building_bye_laws_2024.pdf
- Municipal Administration, Housing and Urban Development Department, Government of Manipur. Unified Zoning/Use Regulation Bye-laws for the Master Plan Areas of Manipur, 2026, Notification No. BBL-101/1/2024-MAHUD-MAHUD, 22 ꯖꯨꯂꯥꯏ 2026-ꯒꯤ, Manipur Gazette Extraordinary No. 157, 23 ꯖꯨꯂꯥꯏ 2026-ꯒꯤ ("Pond, Drain, Rivers and Canals" ꯍꯥꯌꯕ ꯌꯨꯖ ꯖꯣꯟ), https://www.tpmanipur.mn.gov.in/media/filer_public/44/2b/442b7923-b910-494a-83d5-767f50c0c87c/unified_zoning_final_gazette.pdf
- The Manipur Town and Country Planning Act, 1975 (Manipur Act 11 of 1975), ꯁꯦꯛꯁꯟ 1(2), 2 ꯑꯃꯁꯨꯡ 13, https://prsindia.org/files/bills_acts/acts_states/manipur/1975/Act11of1975Manipur.pdf ; ꯑꯃꯁꯨꯡ the Manipur Municipalities Act, 1994 (Act 43 of 1994) (ꯆꯠꯂꯤꯕ ꯃꯐꯝ; ꯏꯔꯝꯒꯤ ꯁꯦꯛꯁꯟꯁꯤꯡ ꯄꯥꯈꯤꯗꯕ)꯫
- The Manipur Flood Plain Zoning Act, 1978 (Manipur Act 10 of 1978), ss.1–7 (ꯀꯠ ꯇꯧꯔꯕ ꯀꯣꯄꯤ ꯑꯃꯗꯒꯤ ꯄꯥꯈꯤꯕ), https://www.indiacode.nic.in/bitstream/123456789/13383/1/the_manipur_flood_plain_zoning_act%2C_1978.pdf
- The Manipur Loktak Lake (Protection) Act, 2006 (Manipur Act 3 of 2006), ꯑꯦꯃꯦꯟꯗ ꯇꯧꯔꯕ ꯃꯇꯨꯡ ꯏꯟꯅ, ꯁꯦꯛꯁꯟ 3, 19 ꯑꯃꯁꯨꯡ 20, https://prsindia.org/files/bills_acts/acts_states/manipur/2006/Manipur%20Act%203%20of%202006.pdf
- The Manipur Conservation of Paddy Land and Wetland Act, 2014 (Manipur Act 10 of 2014), ꯁꯦꯛꯁꯟ 2, 12 ꯑꯃꯁꯨꯡ 18, https://faolex.fao.org/docs/pdf/ind194970.pdf
- The Manipur (Hill Areas) District Councils Act, 1971, ꯑꯦꯃꯦꯟꯗ ꯇꯧꯔꯕ ꯃꯇꯨꯡ ꯏꯟꯅ, ꯁꯦꯛꯁꯟ 29 (ꯃꯇꯨꯡꯒꯤ ꯑꯦꯃꯦꯟꯗꯃꯦꯟꯠꯁꯤꯡꯒꯤ ꯁ꯭ꯇꯦꯠꯀꯤ ꯀꯝꯄꯥꯏꯂꯦꯁꯟ), https://manipur.gov.in/wp-content/uploads/2026/05/The-Manipur-Hill-Areas-District-Councils-Act-1971-subsequent-Amendments.pdf
- Government of India. The Prohibition of Employment as Manual Scavengers and their Rehabilitation Act, 2013.
ꯑꯍꯦꯟꯕ ꯑꯃꯁꯨꯡ ꯐꯣꯔꯝꯁꯤꯡ
| ꯑꯍꯦꯟꯕ / ꯐꯣꯔꯝ | ꯑꯌꯥꯎꯕ |
|---|---|
| 6A | ꯃꯅꯤꯄꯨꯔꯒꯤꯗꯃꯛ ꯀꯦꯄꯥꯁꯤꯇꯤꯒꯤ ꯀꯔꯚꯁꯤꯡ (ꯒ꯭ꯔꯦꯗꯇ ꯑꯃꯁꯨꯡ ꯁꯦꯒꯇ) ꯂꯩꯕ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯏꯟꯂꯦꯠꯀꯤ ꯃꯈꯜꯁꯤꯡ |
| 6B | ꯁꯤꯜꯠ-ꯇ꯭ꯔꯦꯞꯀꯤ ꯁꯥꯏꯖ ꯂꯦꯞꯅꯕ ꯑꯃꯁꯨꯡ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯑꯦꯂꯥꯎꯑꯦꯟꯁꯀꯤ ꯀꯦꯂꯤꯕ꯭ꯔꯦꯁꯟꯒꯤꯗꯃꯛ ꯁꯦꯗꯤꯃꯦꯟꯠ ꯌꯤꯜꯗ |
| 6C | ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯗ꯭ꯔꯣꯏꯡꯁꯤꯡ: ꯂꯧꯊꯣꯀꯄ ꯌꯥꯕ ꯀꯚꯔꯁꯤꯡ ꯂꯩꯕ ꯀꯚꯔ ꯇꯧꯔꯕ ꯂꯝꯕꯤꯒꯤ ꯃꯅꯥꯛꯀꯤ ꯈꯣꯡꯕꯥꯟ, ꯑꯦꯛꯁꯦꯁ ꯆꯦꯝꯕꯔ, ꯂꯩꯃꯨꯒꯤ ꯁꯝꯞ ꯂꯩꯕ ꯏꯟꯂꯦꯠ |
| ꯐꯣꯔꯝ 6-1 | ꯀꯟꯚꯦꯌꯦꯟꯁ ꯗꯤꯖꯥꯏꯟ ꯔꯤꯄꯣꯔꯠꯀꯤ ꯆꯦꯛꯂꯤꯁ꯭ꯠ |
ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ. ꯃꯅꯤꯄꯨꯔꯒꯤ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯁ꯭ꯇꯦꯠ ꯅꯠꯔꯒꯥ ꯃ꯭ꯌꯨꯅꯤꯁꯤꯄꯦꯜꯒꯤ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯑꯃꯠꯇꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯈꯤꯗꯦ: ꯔꯤꯁꯔꯆꯀꯤ ꯃꯇꯝꯗ ꯑꯃꯠꯇꯥ ꯐꯡꯈꯤꯗꯦ, ꯑꯃꯁꯨꯡ ꯐꯡꯂꯕ ꯗꯣꯀꯨꯃꯦꯟꯠ ꯑꯃꯠꯇꯅꯥ ꯀꯔꯤꯒꯨꯝꯕ ꯁꯍꯔ ꯑꯃꯒꯤꯗꯃꯛ ꯗꯤꯖꯥꯏꯟ ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗ, ꯔꯟꯑꯣꯐ ꯀꯣꯑꯦꯐꯤꯁꯤꯌꯦꯟꯠ ꯅꯠꯔꯒꯥ ꯈꯣꯡꯕꯥꯟꯒꯤ ꯁꯥꯏꯖ ꯄꯤꯗꯦ꯫ ꯁ꯭ꯇꯦꯠ ꯑꯁꯤꯒꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯆꯥꯎꯕ ꯏꯔꯝꯒꯤ ꯄ꯭ꯔꯣꯒ꯭ꯔꯥꯝ, ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯒꯤ ꯂꯝꯕꯤꯁꯤꯡꯒꯤ ꯃꯅꯥꯛꯇ AIIB ꯄ꯭ꯔꯣꯖꯦꯛꯠꯀꯤ "ꯃꯅꯥꯛ ꯑꯅꯤꯃꯛꯇ ꯀꯚꯔ ꯇꯧꯔꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡꯒꯤ ꯈꯣꯡꯕꯥꯟ 547 km" ("547 km of both side stormwater covered drains"), ꯃꯁꯤꯅꯥ ꯔꯤꯇꯔꯟ ꯄꯤꯔꯤꯌꯗ, ꯏꯟꯇꯦꯟꯁꯤꯇꯤ ꯅꯠꯔꯒꯥ ꯔꯟꯑꯣꯐ ꯀꯣꯑꯦꯐꯤꯁꯤꯌꯦꯟꯠ ꯑꯃꯠꯇꯥ ꯍꯥꯏꯗꯦ (AIIB, 2024), ꯑꯃꯁꯨꯡ ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯒꯤ ꯃꯥꯁ꯭ꯇꯔ ꯄ꯭ꯂꯥꯟꯗ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ (stormwater) ꯏꯔꯝꯒꯤ ꯁꯦꯛꯁꯟ ꯑꯃꯠꯇꯥ ꯂꯩꯇꯦ꯫ ꯂꯩꯔꯤꯕ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯑꯁꯤ ꯐꯅꯥ ꯊꯕꯛ ꯇꯧꯗꯦ: "ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜ ꯑꯦꯔꯤꯌꯥꯒꯤ ꯂꯩꯔꯤꯕ ꯏꯔꯝ ꯑꯁꯤꯁꯨ ꯐꯕ ꯐꯤꯚꯝꯗ ꯂꯩꯇꯦ ꯑꯃꯁꯨꯡ ꯄ꯭ꯔꯥꯏꯃꯔꯤ ꯈꯣꯡꯕꯥꯟꯗ ꯆꯨꯝꯅꯥ ꯁꯝꯃꯤꯟꯅꯗꯦ꯫ ꯏꯔꯝ ꯁꯤꯁ꯭ꯇꯦꯝꯒꯤ ꯂꯤꯉ꯭ꯛꯁꯤꯡ ꯃꯥꯡꯂꯤ … ꯈꯣꯡꯕꯥꯟꯁꯤꯡ ꯀꯨꯞꯂꯦ … ꯏꯝꯐꯥꯜꯗ ꯂꯝꯕꯤꯁꯤꯡꯒꯤ ꯃꯅꯥꯛꯇ ꯗꯤꯁꯦꯟꯇ꯭ꯔꯥꯂꯥꯏꯖ ꯇꯧꯔꯕ ꯅꯣꯡꯒꯤ ꯏꯁꯤꯡ ꯃꯦꯅꯦꯖꯃꯦꯟꯠ ꯂꯩꯇꯦ" ("The existing drainage in the Greater Imphal area is also not in good condition and is not properly connected to the primary drain. Drainage system links are missing … the drains are clogged … Imphal lacks decentralized stormwater management along streets") (AIIB, 2024)꯫ ꯃꯈꯣꯌꯅꯥ ꯃꯦꯅꯨꯌꯦꯜ ꯑꯁꯤꯒꯤ ꯐꯥꯔꯕ ꯂꯝꯒꯤ ꯑꯦꯗꯤꯁꯟꯁꯤꯡꯅꯥ ꯁꯔꯨꯛ ꯈꯔꯗ ꯈꯛꯇꯃꯛ ꯊꯦꯡꯅꯕ ꯐꯤꯚꯝ ꯑꯃꯗꯁꯨ ꯊꯕꯛ ꯇꯧꯏ꯫ ꯇꯝꯄꯥꯛꯀꯤ ꯂꯝꯗ ꯃꯈꯣꯌ ꯑꯁꯤ ꯇꯨꯔꯦꯜꯒꯤ ꯄꯟꯁꯤꯡꯗ (bund) ꯂꯩꯕ ꯏꯊꯣꯡꯁꯤꯡꯗ (ithong; sluice gate) ꯂꯣꯏꯏ, ꯅꯨꯃꯤꯠ ꯀꯌꯥꯒꯤ ꯃꯇꯝ ꯁꯍꯔꯗꯒꯤ ꯋꯥꯡꯅꯥ ꯂꯩꯕ ꯇꯨꯔꯦꯜꯁꯤꯡꯒꯤ ꯃꯇꯨꯡꯗ, ꯅꯠꯔꯒꯥ ꯃꯃꯥꯡꯗꯒꯤ ꯃꯄꯨꯟꯕ ꯑꯣꯏꯔꯦꯕ ꯄꯥꯠꯁꯤꯡꯗ (pat; lake or wetland, ꯂꯝꯐꯦꯜꯄꯥꯠꯇ ꯂꯩꯕꯒꯨꯝ) ꯑꯃꯁꯨꯡ ꯄꯨꯈ꯭ꯔꯤꯁꯤꯡꯗ ꯂꯣꯏꯏ, ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌꯅꯥ ꯁꯤꯋꯦꯖ (sewage) ꯄꯨꯏ: ꯈꯣꯡꯕꯥꯟ 72-ꯅꯥ BOD 42.45-ꯗꯒꯤ 52.34 mg/L ꯂꯩꯅꯥ ꯅꯝꯕꯨꯜ ꯇꯨꯔꯦꯜꯗ ꯏꯁꯤꯡ ꯊꯥꯗꯣꯀꯏ (NGT-ꯗ ꯁ꯭ꯇꯦꯠꯀꯤ ꯔꯤꯄꯣꯔꯠ, ꯗꯤꯁꯦꯝꯕꯔ 2025)꯫ ꯆꯤꯡꯁꯤꯡꯗ ꯑꯃꯁꯨꯡ ꯇꯝꯄꯥꯛꯀꯤ ꯃꯅꯥꯛꯇ ꯃꯈꯣꯌꯅꯥ "ꯏꯟꯐꯤꯜꯇ꯭ꯔꯦꯁꯟ ꯍꯟꯊꯕ ꯑꯃꯁꯨꯡ ꯔꯟꯑꯣꯐ ꯍꯦꯟꯕ" ("have less infiltration and more run off") ꯗꯤꯁꯥꯡ ꯁꯦꯜꯒꯤ (Disang shale) ꯅꯥꯄꯣꯝꯁꯤꯡꯗꯒꯤ ꯏꯁꯤꯡ ꯈꯣꯃꯖꯤꯜꯂꯤ, ꯃꯈꯣꯌ ꯑꯁꯤ ꯀꯛꯂꯕꯗꯤ ꯂꯥꯟꯊꯔꯀꯏ (MASTEC), ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌꯒꯤ ꯈꯣꯡꯁꯤꯡꯅꯥ (khong; stream) ꯂꯩꯃꯨ ꯇꯝꯄꯥꯛꯀꯤ ꯂꯝ ꯑꯃꯁꯨꯡ ꯂꯣꯛꯇꯥꯛꯇ ꯄꯨꯔꯀꯏ꯫ ꯑꯃꯁꯨꯡ ꯃꯈꯣꯌ ꯑꯁꯤ ꯃꯄꯨ ꯀꯌꯥꯒꯤ ꯃꯔꯛꯇ ꯈꯥꯌꯗꯣꯛꯂꯤ: IMC ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄ ꯎꯔꯕꯟ ꯂꯣꯀꯜ ꯕꯣꯗꯤꯁꯤꯡ, PWD, WRD, DoECC, PHED ꯑꯃꯁꯨꯡ LDA ꯄꯨꯝꯅꯃꯛꯅꯥ ꯒ꯭ꯔꯦꯇꯔ ꯏꯝꯐꯥꯜꯗ ꯈꯣꯡꯕꯥꯟꯁꯤꯡ, ꯆꯦꯅꯦꯜꯁꯤꯡ ꯅꯠꯔꯒꯥ ꯏꯁꯤꯡ ꯂꯧꯕ ꯏꯁꯤꯡꯁꯤꯡ ꯁꯥꯒꯠꯂꯤ ꯅꯠꯔꯒꯥ ꯌꯧꯏ, ꯑꯃꯁꯨꯡ ꯅꯣꯇꯤꯐꯤꯀꯦꯁꯟ ꯑꯃꯠꯇꯅꯥ ꯅꯥꯒꯥ ꯅꯨꯜꯂꯥ (Naga Nullah), ꯋꯥꯏꯁꯦꯜ ꯃꯥꯔꯤꯜ (Waisel Maril) ꯅꯠꯔꯒꯥ ꯁꯃꯨꯁꯥꯡ ꯅꯥꯂꯥ (Shamushang nallah) ꯑꯁꯤ ꯃꯈꯣꯌꯒꯤ ꯃꯔꯛꯇ ꯑꯃꯗ ꯄꯤꯈꯤꯗꯦ (ꯀ꯭ꯂꯣꯖ 6.9-ꯒꯤ ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯛꯄꯥ ꯌꯦꯡꯕꯤꯌꯨ)꯫ ꯅꯣꯡ ꯆꯨꯕ (ꯁꯔꯨꯛ 2) ꯁꯦꯝꯗꯣꯀꯄ ꯑꯁꯤ ꯄꯥꯎꯈꯨꯝꯒꯤ ꯁꯔꯨꯛ ꯑꯔꯥꯛ ꯈꯛꯇꯅꯤ꯫ ꯑꯇꯣꯞꯄ ꯁꯔꯨꯛ ꯑꯔꯥꯛ ꯑꯁꯤꯗꯤ ꯄꯥꯏꯞꯁꯤꯡꯅꯥ ꯄꯨꯕ ꯉꯃꯗꯕ ꯐ꯭ꯂꯣꯁꯤꯡ ꯑꯗꯨ ꯕꯤꯜꯗꯤꯡꯁꯤꯡꯗ ꯏꯁꯤꯡ ꯏꯆꯥꯎ (flood) ꯄꯨꯔꯛꯇꯅꯥ ꯄꯨꯕ ꯂꯩꯃꯥꯏꯒꯤ ꯑꯅꯤꯁꯨꯕ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯃꯅꯤ꯫ ꯃꯗꯨ ꯁꯔꯨꯛ ꯑꯁꯤꯒꯤ ꯗ꯭ꯌꯨꯑꯦꯜ ꯏꯔꯝꯒꯤ ꯋꯥꯈꯜꯂꯣꯟꯅꯤ, ꯃꯁꯤ Kansas City Metro APWA Section 5600 (5601.8, Levels of Service)-ꯗꯒꯤ ꯂꯧꯈꯤꯕꯅꯤ, ꯃꯁꯤꯅꯥ ꯑꯦꯂꯤꯃꯦꯟꯠ ꯈꯨꯗꯤꯡꯃꯛꯇ 1% AEP-ꯒꯤ ꯑꯣꯚꯔꯐ꯭ꯂꯣ ꯂꯝꯕꯤ ꯑꯃꯥ ꯂꯩꯒꯗꯕꯅꯤ ꯍꯥꯌꯅꯥ ꯃꯊꯧ ꯇꯥꯏ꯫