Draft v1.0 prepared by NEER. Not adopted by the Government of Andhra Pradesh or the Government of Puducherry (for Yanam), and has no legal force. About this draft

Annexes to Chapter 2Design Rainfall and Design Storms

These annexes support Chapter 2. Annexes 2A to 2E will hold the statewide rainfall tables that Chapter 2 refers to: the benchmark checks and zone map, sub-daily ratios, grid-to-point factors, temporal patterns and retention depths. Each needs analysis of NIH-DHAARA and IMD records that has not yet been done for this Manual, so each is marked "To be prepared" and gives its intended layout and the rule to use until it is published (Clause 1.11.5). Form 2-1 is a draft form for the Design Rainfall Sheet that every hydrologic submittal must include (Clause 2.13). The Manual is a draft; it is not adopted by any government or agency.


Annex 2A — NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map

Supports Clauses 2.3.1 to 2.3.5 of Chapter 2.

To be prepared. This annex will compare, at benchmark points across the State, the NIH-DHAARA design depths with frequency analyses of long IMD daily station records and of IMD gridded daily data (converted to point values with Annex 2C), for 24 hours and longer and for the AEPs of Table 2.1. It will also contain the map of rainfall zones used by Annexes 2B, 2C and 2E and by the Tier B tables of Chapter 4. It needs NIH-DHAARA values at the benchmark coordinates (NIH), IMD daily and recording-gauge station records and IMD gridded rainfall (IMD), State rain-gauge records (WRD, Ground Water and Water Audit Department), and district and basin boundaries (Survey of India, WRD). Until it is published, design depths are taken from NIH-DHAARA under Clause 2.3.1, the cross-checks of Clause 2.3.3 are reported on Form 2-1, and the zone of a site is the one agreed with the Authority and recorded on Form 2-1.

Table 2A.1 — Benchmark comparison of design depths (layout)

Benchmark point IMD station ID Latitude, longitude Years of record Duration (h) AEP NIH-DHAARA (mm) IMD station analysis (mm) IMD gridded, point value (mm) NIH-DHAARA / IMD station Remarks
        24            
        48            
        72            

2A.1 The zone names below are the working names used in the Tier B table template of Chapter 4 (Clause 4.14.2). Their boundaries, and whether further zones are needed, are to be set by the analysis of this annex.

Table 2A.2 — Rainfall zones (layout)

Zone (working name) Extent (districts, basins) Representative stations Notes
North coastal plains Plains and coastal parts of Srikakulam, Vizianagaram, Visakhapatnam and Anakapalli districts; Vamsadhara, Nagavali, Sarada and the short streams to the coast (CWC subzone 4(a)) [TBC] (candidates: Visakhapatnam, Kalingapatnam) South-west monsoon gives about 59–61% of an annual 1,130–1,200 mm; heaviest falls in October–November cyclones (Hudhud 2014: 38 cm at Gantyada in 24 h). Steep hill-foot catchments above the cities
Eastern Ghats and Agency areas Alluri Sitharama Raju and Parvathipuram Manyam districts and the agency parts of the adjoining districts (CWC subzones 4(a) and 3(f)) [TBC] Above 1,400 mm a year, orographic, south-west monsoon dominant; few recording gauges. Boundary [TBC]
Godavari–Krishna delta and plains Kakinada, Dr B.R. Ambedkar Konaseema, East Godavari, West Godavari, Eluru, Krishna, NTR, Guntur, Bapatla and Palnadu districts (CWC subzones 3(f) and 3(h)) [TBC] (candidates: Gannavaram, Machilipatnam, Kakinada) South-west monsoon gives about 62–66% of an annual 850–1,200 mm; October cyclones and depressions. Highest 1-day point rainfall found for the State: 50.9 cm at T. Kothapalem, 17 Oct 1969. Flat land, tidal, river and Kolleru tailwater
South coastal Prakasam and Sri Potti Sriramulu Nellore districts and the coastal part of Tirupati district (CWC subzones 4(b) and 3(h)) [TBC] (candidates: Ongole, Nellore) North-east monsoon dominant: October–December gives about 45% of the annual rainfall in Prakasam and 61% in Nellore. November and December cyclones (Michaung 2023, Montha 2025)
Rayalaseema north-west Kurnool, Nandyal, Anantapuramu and Sri Sathya Sai districts (CWC subzone 3(h)) [TBC] (candidates: Kurnool, Anantapur) Rain shadow, about 550–670 mm a year, 61–68% in the south-west monsoon; flashy north-east season storms (November 2021)
Rayalaseema south-east YSR Kadapa, Annamayya and Chittoor districts and the inland part of Tirupati district (CWC subzones 3(h) and 4(b); 3(i) near Kuppam [TBC]) [TBC] (candidates: Kadapa, Tirupati) About 700–935 mm a year, mixed seasons (north-east monsoon 36–42%); tank cascades (Annamayya and Pincha, November 2021) and hill-foot runoff at Tirupati

Annex 2B — Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule

Supports Clauses 2.6.1 to 2.6.4 of Chapter 2.

To be prepared. This annex will tabulate, for each zone of Annex 2A, the ratios of the t-hour to the 24-hour design depth from NIH-DHAARA, which are derived from hourly records, against the ratios implied by IMD Das et al. (2022) and by the one-third rule. It needs NIH-DHAARA depths for each duration at representative points in each zone (NIH), IMD recording-gauge data and the IDF values of Das et al. (2022) (IMD). Until it is published, sub-daily depths are read directly from NIH-DHAARA or an approved station IDF (Clause 2.6.1). Where only daily depths are available, the ratios used are those agreed with the Authority, not lower than the CWC Flood Estimation Report ratios for the subzone (Clause 2.6.2), and are recorded on Form 2-1. The one-third rule is not used (Clause 2.6.4).

2B.1 The first row of Table 2B.1 gives the ratios of the one-third rule P(t) = P(24)·(t/24)^(1/3), for comparison only. The 1, 3, 6 and 12 h values are those stated in the commentary to Clause 2.6; the 2 h value is computed from the same formula. The rule shall not be used for design unless this annex confirms it for the zone concerned (Clause 2.6.4).

Table 2B.1 — Ratios P(t)/P(24h) by zone (layout)

Zone Source 1 h 2 h 3 h 6 h 12 h 24 h
All (reference only, not for design) One-third rule 0.35 0.44 0.50 0.63 0.79 1.00
North coastal plains NIH-DHAARA           1.00
North coastal plains IMD Das et al. (2022)           1.00
Eastern Ghats and Agency areas NIH-DHAARA           1.00
Eastern Ghats and Agency areas IMD Das et al. (2022)           1.00
Godavari–Krishna delta and plains NIH-DHAARA           1.00
Godavari–Krishna delta and plains IMD Das et al. (2022)           1.00
South coastal NIH-DHAARA           1.00
South coastal IMD Das et al. (2022)           1.00
Rayalaseema north-west NIH-DHAARA           1.00
Rayalaseema north-west IMD Das et al. (2022)           1.00
Rayalaseema south-east NIH-DHAARA           1.00
Rayalaseema south-east IMD Das et al. (2022)           1.00

2B.2 Depths from fixed observation windows are converted to true-interval depths with the factors of Clause 2.6.3, repeated in Table 2B.2. They are the standard WMO (Hershfield) values and are not provisional.

Table 2B.2 — Fixed-interval adjustment factors (Clause 2.6.3)

Number of fixed observation intervals in the duration Factor
1 1.13
2 1.04
3–4 1.02

Annex 2C — Grid-to-point factors

Supports Clauses 2.7.1 and 2.7.4 of Chapter 2.

To be prepared. This annex will give the factors that convert grid-average design depths (for example from 0.25° cells) to point depths, by zone, duration and AEP. It needs paired frequency analyses of IMD gridded rainfall and of the IMD and State gauges inside each cell (IMD, WRD), the benchmark points of Annex 2A, and a stated method for deriving the factors. Until it is published, design depths are taken as point values from NIH-DHAARA or an approved station IDF (Clauses 2.3.1 and 2.3.2). Grid-average values are not used as design depths unless a conversion agreed with the Authority is recorded on Form 2-1 (Clause 1.11.5).

2C.1 The commentary to Clause 2.7 shows why the factors matter: on 31 Aug 2024 the NTR district average for 08:30–18:00 was reported as 121.2 mm, while the Veerullapadu mandal gauge recorded 215.6 mm over the same hours. Daily IMD gridded rainfall (0.25°) and district averages are area values and need these factors before any use as point depths.

Table 2C.1 — Grid-to-point factors (layout)

Zone Grid product and cell size Duration (h) AEP Factor (point / grid) Stations used Years of record
    24        
    48        
    72        

Annex 2D — Andhra Pradesh temporal patterns (Huff curves)

Supports Clauses 2.9.3 and 2.9.4 of Chapter 2, and Clause 11.7.3 of Chapter 11.

To be prepared. This annex will give dimensionless time-distribution (mass) curves of Andhra Pradesh storms, in the form introduced by Huff (1967), by zone, storm-duration class and quartile, at stated probability levels. It needs storm hyetographs from recording gauges and automatic weather stations (IMD, WRD, APSDMA), separated into independent storms by a stated rule, and Cyclone Hudhud (October 2014), the November 2021 storms over Rayalaseema and Nellore, Cyclone Michaung (December 2023), the Vijayawada storm of 31 August 2024 and Cyclone Montha (October 2025) among them. Until it is published, design storms use the alternating-block pattern of Clause 2.9.1 and the 48- and 72-hour pattern of Clause 2.9.2; for catchments of 25–5,000 km², the CWC Flood Estimation Report curves may be used with a sensitivity run under Clause 2.9.1 (Clause 2.9.4). SCS Type distributions are not used (Clause 2.9.3). For the disaggregation of daily records in continuous simulation (Clause 11.7.3), the method is agreed with the Authority and recorded (Clause 1.11.5).

Table 2D.1 — Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)

Fraction of storm time 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
10% probability curve 0                   1.0
50% probability curve 0                   1.0
90% probability curve 0                   1.0

2D.1 Each table shall state the zone, the duration class, the quartile (the quarter of the storm in which most rain fell), the number of storms analysed and the period of record.

Reference: Huff, F.A. (1967). Time distribution of rainfall in heavy storms. Water Resources Research 3(4), 1007–1019.


Annex 2E — Retention percentile depths by zone

Supports Clauses 2.8.3 and 2.10.1 to 2.10.2 of Chapter 2, Clause 4.4 of Chapter 4 and Chapter 8.

To be prepared. This annex will give, for each zone of Annex 2A, the retention design depth P_R: the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record (Clause 2.10.1). It needs long daily records at stations in each zone (IMD, WRD) and IMD gridded data with the factors of Annex 2C where stations are sparse. Until it is published, P_R is computed by the definition of Clause 2.10.1 from the long-term daily record of a station agreed with the Authority, by the steps in 2E.1, and recorded on Form 2-1 (Clause 1.11.5).

2E.1 Computing P_R from a daily record.

  1. Take the daily (24-hour) rainfall series of the station for its full record.
  2. Keep only the days with rain of 2.5 mm or more (wet days).
  3. Rank the wet-day depths and take the depth not exceeded on 90% of them (the 90th percentile).
  4. Do not apply the climate factor (Clause 2.8.3) or the fixed-interval factor; P_R is a statistic of everyday rainfall, not an AEP design depth.
  5. Record the station, the period of record, the number of wet days and P_R on Form 2-1.

Table 2E.1 — Retention depth P_R by zone (layout)

Zone Stations or grid cells used Period of record Number of wet days (≥ 2.5 mm) P_R, 90th percentile (mm) Issued on
North coastal plains          
Eastern Ghats and Agency areas          
Godavari–Krishna delta and plains          
South coastal          
Rayalaseema north-west          
Rayalaseema south-east          

Form 2-1 — Design Rainfall Sheet

Supports Clauses 2.3 to 2.13 of Chapter 2, and Clause 10.4.1(d) of Chapter 10.

Draft form — Andhra Pradesh Stormwater Design Manual, Draft v1.0. One sheet for each hydrologic submittal. The steps follow Figure 2.3 of Chapter 2.

Table 2F.1 — Form 2-1: site, source and storms

No. Item (clause) Entry
A. Site (Clause 2.13, item 1)
A1 Project and site ______
A2 Site coordinates (latitude, longitude, decimal degrees) ______
A3 Rainfall zone (Annex 2A, or as agreed with the Authority) ______
A4 Contributing catchment area (km²) (Clause 2.7) ______
A5 Design life: more than 25 years / temporary works, 5 years or less (Clause 2.8.2) ______
A6 Outfall under tidal or river backwater influence: Yes / No (Clauses 2.5.3, 2.12) ______
B. Source (Clauses 2.3, 2.3.5; item 2)
B1 NIH-DHAARA: version or access date ______
B2 Coordinates queried ______
B3 Screenshot or export of the values extracted attached: reference ______
B4 Station IDF used (Clause 2.3.2): No / Yes — station, ID, distance from site (km) ______
B5 Station IDF: years of recording-gauge data (30 or more); published or approved by ______
B6 Station IDF: change of terrain or coastal exposure between gauge and site: None / describe ______
C. AEPs and durations (Clauses 2.4, 2.5)
C1 Elements designed and their AEPs (Table 2.1) ______
C2 Conveyance: Tc and design duration (not less than 10 min) (Clause 2.5.1) ______
C3 Storage: durations checked from {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48 and 72 h included (Clause 2.5.2) ______
C4 Critical duration found for each storage element ______
D. Conversions
D1 Sub-daily depths: read directly / from Annex 2B ratios / from ratios agreed with the Authority (Clauses 2.6.1, 2.6.2) ______
D2 Fixed-interval factor applied: none (true-interval source) / 1.13 / 1.04 / 1.02 (Clause 2.6.3) ______
D3 Grid-to-point factor: not needed (point source) / Annex 2C / agreed value (Clause 2.7.1) ______
D4 ARF: 1.0 (10 km² or less; single-site storage) / CWC curve / interpolated (Clauses 2.7.2–2.7.4) ______
D5 Climate factor: 1.20 (≤ 6 h) and 1.10 (> 6–72 h) / 1.0 temporary works / projected depths under Clause 2.8.4 ______
E. Cross-checks (Clause 2.3.3; item 4)
E1 IMD Das et al. (2022) values for 1–24 h: reported in Table 2F.2 ______
E2 CWC subzone 3(f) / 3(h) / 4(a) / 4(b) 24-hour point value, catchments of 25–5,000 km²: subzone used ______
E3 CWC floor governs for any AEP: No / Yes — AEPs ______
F. Retention depth (Clause 2.10)
F1 P_R (mm) and source: Annex 2E zone value / computed under Annex 2E, 2E.1 — station and period ______
F2 No climate factor applied to P_R (Clause 2.8.3): confirmed ______
G. Design storms (Clauses 2.9, 2.11, 2.12; items 5 and 6)
G1 Storms up to 24 h: alternating block, peak at 50%; time step (≤ Tc/3 and ≤ 15 min) ______
G2 48 and 72 h storms: built under Clause 2.9.2 (Table 2F.3) ______
G3 Other pattern used: none / Annex 2D / CWC FER with sensitivity run (Clauses 2.9.3, 2.9.4) ______
G4 Hyetographs attached as a table and a plot for each design storm: reference ______
G5 AMC: III for every design storm in October–December, whatever its duration; II for storms in other months (Clause 2.11.4) ______
G6 Pre-development condition: greenfield, open land in good condition for the mapped HSG (Clause 2.11.5) ______
G7 Release criterion: standard, Q_post ≤ 0.9 × Q_pre (Clause 2.11.2) / flood-sensitive, mixed-frequency rule (Clause 2.11.3) ______
G8 Tailwater joint cases run (Clause 2.12): case (a) MHWS + sea-level allowance; case (b) 10% AEP 48 h storm with 1% AEP still-water level + sea-level allowance; governing case ______
H. Prepared by
H1 I confirm that the values above are those extracted and used in the submittal. Name, registration number, signature, date ______

Design depth = source depth × fixed-interval factor × grid-to-point factor × ARF × climate factor. Where the design depth is lower than the CWC floor for the same AEP, the floor is adopted (Clause 2.3.3).

Table 2F.2 — Form 2-1: depth table (Clause 2.13, item 3)

AEP (T-yr) Duration Source depth (mm) Fixed-interval factor Grid-to-point factor ARF Climate factor Design depth (mm) IMD Das et al. (2022) (mm) CWC floor (mm) Adopted depth (mm)
                     
                     
                     
                     

Table 2F.3 — Form 2-1: 48- and 72-hour storm construction (Clause 2.9.2)

AEP (T-yr) Duration (h) Total design depth (mm) 24 h design depth, final 24 h (mm) Remainder (mm) Hours before the final 24 h Uniform intensity before the final 24 h (mm/h)
  48       24  
  72       48