Draft v1.0 prepared by NEER. Not adopted by the Government of Andhra Pradesh or the Government of Puducherry (for Yanam), and has no legal force. About this draft

Chapter 2Design Rainfall and Design Storms


2.1 Purpose and scope

2.1.1 This chapter sets the rainfall inputs for every hydrologic calculation in this Manual: drain and inlet sizing (Chapter 6), retention and detention sizing (Chapter 4), downstream and tailwater analysis (Chapter 5), and waterbody and tank works (Chapter 7).

2.1.2 It specifies:

  • (a) the approved sources of design rainfall depth and intensity;
  • (b) how depths are converted between durations, between point and area, and from present to future climate;
  • (c) how design storms (hyetographs) are constructed; and
  • (d) the storms that must be applied to pre- and post-development conditions.

2.1.3 This chapter applies throughout Andhra Pradesh. Where a Municipal Corporation, Municipality, Nagar Panchayat, APCRDA or an Urban Development Authority has adopted a stricter rainfall standard under Chapter 1, the stricter standard governs.

Commentary. Most past drainage failures in Andhra Pradesh trace to the rainfall input, not the hydraulics. No Andhra Pradesh city has a published station IDF relationship. The only State design value found in an official document is APCRDA's Amaravati criterion of 54.77 mm/h for the 1-in-5-year drain, derived "from Gannavaram Airport 1-hour rainfall data" with no stated duration or IDF coefficients (APCRDA, undated). The Amaravati flood works adopt a 100-year 24-hour depth of 222 mm (APCRDA/ADCL, 2018), below the 260–280 mm the same report reads from IMD isopluvials and below the 100-year 1-day value of 247.9 mm that IITM computed for Vijayawada (Pant et al., 2005); the World Bank (2024) found that estimate to rest on a limited dataset. The one Andhra Pradesh panel in IMD Das et al. (2022), Machilipatnam, appears identical to the panels of several unrelated cities and is not used as a station value. Fixing one transparent source and method for the whole state is the main purpose of this chapter.


2.2 Definitions

Term Meaning in this Manual
Annual exceedance probability (AEP) Probability that a given rainfall depth is equalled or exceeded in any one year. A 1% AEP storm is the "100-year" storm. Both forms are used here: T-year = 1/AEP.
IDF / DDF Intensity–duration–frequency and depth–duration–frequency relationships for a location.
Point rainfall Rainfall at a single location, as measured by a rain gauge.
Design storm A hyetograph (rainfall depth versus time) of stated AEP, duration and temporal pattern.
Critical duration The storm duration that produces the largest peak flow, water level or storage requirement for the element being designed.
Areal reduction factor (ARF) Ratio of catchment-average rainfall to point rainfall for the same AEP and duration.
South-west monsoon season (JJAS) June–September. It gives about 59–68% of annual rainfall in the north coastal, delta and north-western Rayalaseema districts (ICAR-CRIDA district plans), and governs seasonal groundwater and river levels in the deltas.
Cyclone and north-east monsoon season (OND) October–December, when most of the State's damaging storms occur. Normals for 1971–2020 are 32 of 104 cm in Coastal Andhra Pradesh and Yanam and 24 of 73 cm in Rayalaseema (IMD); Nellore receives about 61% of its annual rainfall in these months. About three in four cyclones that affected the Andhra coast in 1971–2020 did so in October–December, with a secondary peak in May (count from the IMD Visakhapatnam list). Design statistics use annual maxima from all seasons.
Climate factor (CF) Multiplier applied to present-day design depths to represent the design-life climate.
Approved source A rainfall source listed in Clause 2.3.

2.3 Approved sources of design rainfall

2.3.1 Primary source. Design rainfall depths and intensities shall be taken from the National Institute of Hydrology, Roorkee NIH-DHAARA platform (Design Hydrology and Advanced Rainfall Analysis, nihdhaara.in). Use its IDF / frequency tools for the site's coordinates, for each duration and AEP required by Clause 2.4.

2.3.2 Station IDF. A station-specific IDF relationship may be used in place of 2.3.1 only if all of the following hold:

  • (a) it is derived from at least 30 years of recording-gauge (hourly or finer) data;
  • (b) it has been published or approved by IMD, the State Hydrology Authority or the approving authority; and
  • (c) the gauge is within 10 km of the site, with no major change of terrain or coastal exposure in between.

Where a station IDF is used, the design value shall be the greater of the station value and the NIH-DHAARA value.

2.3.3 Cross-checks (mandatory, not alternatives). The designer shall report, but need not adopt, the following values for comparison:

  • (a) the IMD isopluvial / IDF values of Das et al. (2022), MAUSAM 73(4), for durations of 1–24 h;
  • (b) for catchments of 25–5,000 km², the 24-hour point rainfall from the CWC Flood Estimation Report for subzone 3(f) (Lower Godavari), 3(h) (Krishna and Pennar), 4(a) (Upper Eastern Coast) or 4(b) (Lower Eastern Coast), as applicable.

Where the design value is lower than the CWC 3(f)/3(h)/4(a)/4(b) value for the same AEP, the CWC value shall be adopted as a floor.

2.3.4 Not permitted. None of the following shall be used as a design rainfall source:

  • (a) generalised all-India IDF formulae (for example Kothyari & Garde, 1992);
  • (b) rainfall values that cite no source, including vendor or web-calculator tables;
  • (c) single-event maxima; or
  • (d) design intensities carried forward from a previous project without a stated AEP.

NIH-DHAARA Primary source (Cl. 2.3.1) hourly-based IDF, all durations Approved station IDF ≥30 yr recording gauge, ≤10 km optional (Cl. 2.3.2) Take the greater per AEP and duration CWC FER (state subzone) floor, 25–5,000 km² (Cl. 2.3.3) IMD Das et al. 2022 reported cross-check, 1–24 h Adjustments, in order 1. Fixed-interval → true-interval (Cl. 2.6.3) 2. Grid → point, if grid values (Cl. 2.7.1) 3. Areal reduction, >10 km² only (Cl. 2.7.3) 4. Climate factor 1.20 / 1.10 (Cl. 2.8) → Design depth → hyetograph (Cl. 2.9) Dashed: cross-checks reported on Form 2-1; CWC value governs only if higher.

Figure 2.1 — Design rainfall source hierarchy and adjustment sequence. Original drawing for this Manual.

2.3.5 Version control. Every submittal shall record the source, its version or access date, the coordinates queried, and the values extracted (Clause 2.13).

Commentary. NIH-DHAARA is a national, publicly accessible product from a Government of India institution, and it can be queried at any point in the State. That makes it a reproducible default that an approving authority can check. NIH-DHAARA's sub-daily values are derived from hourly records, not disaggregated from daily totals. That makes it the only public source suitable for sizing drains, which depend on short-duration intensity. Its values should still be checked against the long IMD daily record at 24 hours and longer (Annex 2A).


2.4 Design return periods (summary)

2.4.1 Design AEPs are set in the chapters for each element. They are summarised here so that the correct rainfall is extracted at the start of design.

Table 2.1 — Design return periods (summary)

Element Design AEP (return period) Check event Chapter
Minor drains: Visakhapatnam, Vijayawada and Guntur core and high-density areas 10% (10-yr) 1% (100-yr) overland path 6
Minor drains: other Class I urban areas 20% (5-yr) 1% overland path 6
Minor drains: other areas 50% (2-yr) 1% overland path 6
Arterial roads and crossings 2–4% (25–50-yr) next higher AEP 6
Collector / local roads 4% / 10% (25 / 10-yr) 2% / 4% (50 / 25-yr), plus the 1% overland path 6
Major (overland) system 1% (100-yr) — 6
Retention volume Percentile daily rainfall (Clause 2.10) — 4
Detention: standard catchments 50%, 10%, 1% (2, 10, 100-yr) 1% emergency spillway 4
Detention: flood-sensitive catchments Mixed-frequency rule, Clause 2.11 1% 4
Building floor levels 1% + 0.5 m freeboard — 6
Detention emergency spillway 1% with outlet blocked 0.2% (500-yr) where high hazard 4

Commentary. These values exceed the CPHEEO (2019) national advisory minimums of 5-yr (Class I cities) and 2-yr (other areas). CPHEEO allows a State to set higher values. The values are set in Chapters 4 and 6, and the table is reproduced here for convenience.


2.5 Design durations

2.5.1 Conveyance elements (pipes, open drains, inlets, culverts) shall be designed with the intensity for a duration equal to the time of concentration (Tc) of the contributing area (Chapter 3). The minimum duration is 10 minutes.

2.5.2 Storage elements (detention, retention, tanks, pumped sumps) shall be checked for every duration in the set {1, 2, 3, 6, 12, 24, 48, 72 h}. The largest required storage or water level governs. The 24-, 48- and 72-hour storms are mandatory checks at every site, whatever the critical-duration result.

2.5.3 Tidally influenced outfalls. For storage draining to a tidally influenced outfall (Chapter 5), the 48- and 72-hour storms shall also be run with the tailwater boundary of Clause 2.12.

Commentary. Andhra Pradesh's worst rainfall floods have come from storms lasting one to three days on wet ground. The largest 1-day point rainfall found for the State, 50.9 cm at T. Kothapalem in the Krishna delta on 17 Oct 1969, was part of a 3-day total of 82.2 cm (Pant et al., 2005). Cyclone Michaung gave 222 mm at Bapatla and 218.1 mm at Nellore in the 24 hours to 08:30 on 5 Dec 2023, and 24 cm at Bhimadole in Eluru district the next day (IMD). In November 2021 a series of depressions brought Rayalaseema 302 mm against a monthly normal of 70.2 mm (IMD, Northeast Monsoon 2021 report), and the Annamayya dam on the Cheyyeru breached on 19 November after an upstream ring bund failed. A rule based only on critical duration, applied to a small site, picks a 1–2 hour storm and misses this failure mode. That is why the long-duration checks are mandatory.


2.6 Sub-daily rainfall

2.6.1 Where NIH-DHAARA or an approved station IDF provides values directly for the required duration, those values shall be used.

2.6.2 Where only daily (24-hour) depths are available for a duration below 24 hours, the sub-daily depth shall be derived using the ratio set of Annex 2B. These are duration-to-24-hour ratios calibrated to Andhra Pradesh recording gauges. They shall not be lower than the ratios of the CWC Flood Estimation Report for the subzone. The IMD Das et al. (2022) curves are not used as a floor in Andhra Pradesh, because its panels for Andhra Pradesh stations appear to repeat a generic curve.

2.6.3 Fixed-interval adjustment. Depths from fixed observation windows (for example 08:30–08:30 IST daily data, or clock-hour data) shall be converted to sliding-window ("true interval") depths:

  • 1.13 for a single fixed observation interval;
  • 1.04 for 2 intervals;
  • 1.02 for 3–4 intervals.

This adjustment does not apply where the approved source already gives true-interval values.

2.6.4 The empirical relationship P(t) = P(24)·(t/24)^(1/3) shall not be used for design unless Annex 2B confirms it for the zone concerned.

Commentary. The one-third power rule is common in Indian project reports, but no primary IMD source for it was found during research for this Manual. It applies one fixed curve shape everywhere: P(1h)/P(24h) = 0.35, P(3h) = 0.50, P(6h) = 0.63 and P(12h) = 0.79. It cannot represent the difference between a short convective burst and a long monsoon soak, and it tends to understate short-duration depths in convective coastal storms. Annex 2B shall tabulate the NIH-DHAARA ratios P(t)/P(24h) against these values by zone. That comparison shows whether the rule is acceptable anywhere in the State and corrects older daily-based analyses. The fixed-interval factors are the standard WMO (Hershfield) values. The IMD 2022 study applies similar clock-hour to any-hour corrections.


2.7 Point, grid and areal rainfall

2.7.1 Design depths are point values. Where an approved source provides grid-average values (for example 0.25° cells), they shall be converted to point values with the grid-to-point factors in Annex 2C before use.

2.7.2 For catchments ≤ 10 km², ARF = 1.0.

2.7.3 For catchments > 10 km², apply ARF as follows:

  • for 25–5,000 km² in subzone 3(f), 3(h), 4(a) or 4(b): use the ARF curves of the applicable CWC Flood Estimation Report;
  • for 10–25 km²: interpolate linearly between ARF = 1.0 at 10 km² and the CWC value at 25 km².

2.7.4 An ARF shall never be applied to storage design for a single development site.

Commentary. Gridded and district-average return levels are much lower than point values. For example, on 31 Aug 2024 the NTR district average for 08:30–18:00 was reported as 121.2 mm, while the mandal gauge at Veerullapadu, in the Budameru catchment, recorded 215.6 mm over the same hours (State mandal gauges, as reported by the Deccan Chronicle). Using grid values as point values without correction would make site-level design unsafe.


2.8 Climate factor

2.8.1 Until a statewide future-climate rainfall product is adopted, present-day design depths shall be multiplied by the following interim climate factors:

Table 2.2 — Interim climate factors

Duration Climate factor (CF)
≤ 6 h 1.20
> 6 h to 72 h 1.10

2.8.2 The CF applies to all elements with a design life of more than 25 years. For temporary works (design life ≤ 5 years), CF = 1.0.

2.8.3 The climate factor does not apply to the retention depth (Clause 2.10) or to the water quality volume depth (Chapter 8). Those depths are percentile or frequent-event statistics of everyday rainfall, not AEP design values.

2.8.4 Where NIH-DHAARA, or a product adopted on review under Clause 2.14, provides projected future-climate depths, those depths shall replace the interim factors.

Commentary. CPHEEO (2019) considers a fixed climate factor "not feasible" nationally and recommends trend testing instead. That leaves designers without a usable number. The 1.20 short-duration factor matches the UK value cited by CPHEEO itself. Observed trends in the State point the same way: south-west monsoon rainfall increased significantly at Gannavaram, Machilipatnam and Visakhapatnam over 1969–2014, more at the urban stations than around them (Naga Ratna and Mohanty, 2017), and the 95th-percentile daily rainfall rose in 20 of 24 grid cells over Andhra Pradesh and Telangana in 1969–2019, most strongly in mid and south coastal Andhra Pradesh (Chakraborty et al., 2022). Nationally, Ali and Mishra (2018) project 3-hourly 100-year maxima rising by about 20% at 1.5 °C and 25% at 2.0 °C of warming, and Mukherjee et al. (2018) find 1–5-day extremes rising by 10–30%. No Andhra Pradesh-specific design uplift has been published. Trends are weaker or negative in parts of south-western Rayalaseema, but the November 2021 storms there give no basis for a lower factor in that region.


2.9 Temporal patterns (design hyetographs)

2.9.1 Storms up to 24 hours. Use the nested alternating-block method:

  • construct the storm from the same IDF relationship (after the climate factor), at time steps no longer than Tc/3 and no longer than 15 minutes;
  • place the peak block at 50% of the storm duration.

2.9.2 48- and 72-hour storms (monsoon pattern). Construct as follows:

  • (a) The total storm depth equals the design depth for the full duration (48 or 72 h).
  • (b) The final 24 hours contain the 24-hour design depth for the same AEP, distributed by the alternating-block method of 2.9.1.
  • (c) The remaining depth (total minus the 24-hour depth) is spread uniformly over the preceding 24 or 48 hours.

2026-10-31T09:49:37.193022 image/svg+xml Matplotlib v3.9.4, https://matplotlib.org/ 0 6 12 18 24 Time (h) 0 10 20 30 40 50 60 70 80 Rainfall (mm per h) (a) 24-h alternating-block storm 0 12 24 36 48 60 72 Time (h) Remaining 72-h depth, spread uniformly (antecedent rain fills soils, RWH sumps, tanks) 24-h design depth on the final day (alternating block, Clause 2.9.1) (b) 72-h monsoon storm Illustrative — not design values (100-yr 24-h = 350 mm, 72-h = 520 mm, hourly blocks).

Figure 2.2 — (a) 24-hour alternating-block design storm; (b) 72-hour monsoon design storm with the 24-hour design depth on the final day. Illustrative depths only. Original drawing for this Manual. The alternating-block method follows Chow, Maidment & Mays, Applied Hydrology (1988), §14.4.

2.9.3 Other temporal patterns. Huff-type or mass-curve patterns derived from Andhra Pradesh storms may be used instead of 2.9.1 and 2.9.2 only after they are published in Annex 2D. SCS Type I, IA, II and III distributions shall not be used.

2.9.4 Large catchments. For catchments of 25–5,000 km², the CWC Flood Estimation Report time-distribution curves may be used, and a sensitivity run with 2.9.1 shall be reported.

Commentary. The alternating-block storm embeds every shorter-duration design intensity in one hyetograph. That makes it conservative and consistent across durations. The 72-hour pattern puts the most intense day last. This reproduces the Andhra Pradesh sequence: October–December storms arrive after the south-west monsoon and earlier depressions have filled tanks, soils and rivers. The November 2021 storm followed a series of mid-November depressions (IMD, Northeast Monsoon 2021 report), and the Vijayawada storm of 31 Aug 2024 fell while the Krishna was rising to a record inflow at Prakasam Barrage. SCS distributions are excluded because they come from US convective and Gulf storm data and have no basis in Andhra Pradesh records.


2.10 Retention rainfall depth

2.10.1 The retention design depth is the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record, read from the zone value in Annex 2E.

2.10.2 The site must retain on site the runoff from this depth (Chapter 4). Retention earns a detention credit equal to the reduction in required detention storage found by routing with the retention in place (Clause 4.4.6). The credit is not the retained volume subtracted one-for-one.

Commentary. This follows the Kansas City Metro APWA 5600 (2025.01) Required Retention Volume concept and Georgia's 1.0-inch runoff reduction standard. Both are based on percentile storms. A percentile depth is a statistic of everyday rainfall, not an AEP value, so it is computed from the daily record rather than from the frequency curves.


2.11 Design storms for pre- and post-development comparison

2.11.1 Same storm for both scenarios. Pre- and post-development runs shall use the same design storms:

  • same AEP, duration, temporal pattern and climate factor;
  • same antecedent moisture condition (Clause 2.11.4).

The two runs differ only in land surface parameters and Tc.

2.11.2 Standard catchments. For each of the 50%, 10% and 1% AEP storms and each duration in Clause 2.5.2:

Q_post(T) ≤ 0.9 × Q_pre(T)

2.11.3 Flood-sensitive catchments (as listed in Chapter 4: the Budameru (Vijayawada), Kondaveeti Vagu and Pala Vagu (Amaravati), Kolleru and Tirupati catchments, and any catchment notified by the authority). The mixed-frequency rule applies:

Q_post(1% AEP, 100-yr) ≤ Q_pre(10% AEP, 10-yr), and Q_post(50% AEP, 2-yr) ≤ Q_pre(50% AEP, 2-yr),

The post-development peak is checked for each duration in Clause 2.5.2. The caps are taken at the pre-development critical duration. The 10-yr cap is the largest pre-development 10-yr peak over all durations, and the 2-yr cap is the largest pre-development 2-yr peak over all durations. Each cap applies to every post-development duration.

2.11.4 Antecedent moisture. Use AMC III (wet conditions) for every design storm in the cyclone and north-east monsoon season (October–December), whatever its duration. Use AMC II (average conditions) for storms in other months.

2.11.5 Pre-development condition. Pre-development is defined in Chapter 3: greenfield, open land in good condition for the mapped hydrologic soil group. Existing impervious cover is not counted as pre-development.

Commentary. Matching each site's post-development peak to its own pre-development peak does not protect the catchment. Denver's analysis found that 100% matching at every site still produced 106% of historic peak downstream, which led to the 90% rule. The mixed-frequency rule is stricter. It caps the 100-yr post-development release at what the undeveloped site produced in a 10-yr storm. Malaysia (DID 2008: all ARIs ≤ pre-development 2-yr) is a tropical precedent for this kind of cap. AMC III for long storms reflects that monsoon extremes arrive after weeks of rain. In Andhra Pradesh the damaging storms of October–December fall on ground already wetted by the south-west monsoon and October rain, and in the Godavari basin more than 80% of flood-causing extreme rain events occurred under wet antecedent conditions (Garg and Mishra, 2019). Cyclone floods in India are strongly linked to antecedent soil moisture, and April–May cyclones on dry soils rarely cause floods. This Manual therefore uses AMC III for every design storm in October–December, whatever its duration, and AMC II otherwise (Clause 2.11.4). Black cotton soils that are cracked and dry absorb the first rain of a season; AMC III assumes the cracks have closed. No Andhra Pradesh study has yet validated AMC classes against observed runoff.

Illustrative scale of the mixed-frequency rule. The values below are not design values. They assume a 2 ha site in coastal Andhra Pradesh with 24-h depths of 200 mm (10-yr) and 350 mm (100-yr), SCS-CN runoff with Ia = 0.2S, and CN 70 pre-development and CN 92 post-development:

Table 2.3 — Illustrative scale of the mixed-frequency rule (not design values)

Case Runoff depth Runoff volume (2 ha)
Pre-development, 10-yr 24 h 111 mm 2,210 m³
Post-development, 100-yr 24 h 325 mm 6,500 m³

The post-development 100-yr storm generates about three times the runoff volume of the pre-development 10-yr storm. A peak-rate cap at the pre-development 10-yr level means most of the difference must be stored and released slowly, so storage of the order of 0.2 m³ per m² of site may be needed. For this reason the rule applies only in flood-sensitive catchments (Clause 2.11.3); elsewhere the 0.9 × Q_pre rule of Clause 2.11.2 applies.


2.12 Joint occurrence with tailwater

2.12.1 For outfalls under tidal or river backwater influence, the design rainfall of this chapter shall be combined with the tailwater conditions of Chapter 5 as follows. The more severe case governs.

  • (a) Design rainfall (AEP as required) with a mean high water springs (MHWS) tailwater plus the sea-level allowance.
  • (b) A 10% AEP (10-yr) 48-hour storm with the 1% AEP still-water level (tide plus surge) plus the sea-level allowance.

Commentary. When Cyclone Hudhud crossed Visakhapatnam on 12 Oct 2014, the port tide gauge recorded a surge of 1.4 m while the heaviest rain was falling on the city and its hinterland, up to 38 cm at Gantyada in the 24 hours to 08:30 on 13 October (IMD RSMC report on Hudhud). Inland, river stage plays the same role: the Budameru flood of 31 Aug–2 Sep 2024 reached Vijayawada while the Krishna was rising to a record inflow of 11.36 lakh cusecs at Prakasam Barrage (CWC data, as reproduced by SANDRP). Because rainfall and surge share a cyclone cause, they cannot be treated as independent. Case (b) is a simple joint-probability surrogate until a statistical joint analysis is adopted.


2.13 Submittal requirements

Every hydrologic submittal shall include a Design Rainfall Sheet (Form 2-1) stating:

  1. the site coordinates and zone;
  2. the source (Clause 2.3), version or access date, and a screenshot or export of the values extracted;
  3. a depth table for each AEP and duration used, before and after the fixed-interval factor, grid-to-point factor, ARF and climate factor;
  4. the cross-check values of Clause 2.3.3 and the floor check;
  5. the hyetographs used, as a table and a plot, for each design storm; and
  6. the AMC and pre-development definition adopted.

Figure 2.3 shows the steps of this chapter in the order in which the sheet records them.

Figure 2.3 — From design rainfall source to design storm Seven steps in sequence: choose the approved source; set AEPs and durations; point depth for each AEP and duration; grid to point and areal reduction; climate factor; temporal pattern; design storm. A side panel lists what Form 2-1 records, and a second panel shows that the retention depth takes a separate route without the climate factor. From design rainfall source to design storm Steps a designer follows in Chapter 2, with the governing clause (schematic flowchart) 1 Choose the approved source Cl. 2.3 NIH-DHAARA at the site coordinates. Station IDF only with ≥ 30 yr record within 10 km; the greater value governs. Report the IMD (Das et al. 2022) cross-check; CWC subzone value is a floor for 25–5,000 km². 2 Set the AEPs and durations Cl. 2.4–2.5 AEP for each element from Table 2.1. Conveyance: duration = Tc, not less than 10 min. Storage: every duration in {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48, 72 h always. 3 Point depth for each AEP and duration Cl. 2.6 Read the depth from the source for each duration. If only daily depths exist, use the Annex 2B ratios (not the one-third rule). Fixed-interval data × 1.13 / 1.04 / 1.02 for 1 / 2 / 3–4 intervals. 4 Grid to point, then areal reduction Cl. 2.7 Grid-average values × grid-to-point factor (Annex 2C). ARF = 1.0 up to 10 km²; CWC curves above 25 km², linear between. No ARF for storage on a single development site. 5 Apply the climate factor Cl. 2.8 × 1.20 for durations ≤ 6 h; × 1.10 for > 6 h to 72 h. CF = 1.0 for temporary works (design life ≤ 5 years). Not applied to the retention depth or the WQv depth. 6 Build the temporal pattern Cl. 2.9 ≤ 24 h: alternating block, peak at 50%, time step ≤ Tc/3 and ≤ 15 min. 48 / 72 h: the 24 h design depth in the final 24 h; the remainder spread uniformly before it. SCS Type I, IA, II and III are not permitted. 7 Design storm (hyetograph) Cl. 2.11–2.12 Same storms for pre- and post-development runs. AMC II for storms ≤ 6 h; AMC III for 12 h and longer. Tidal or backwater outfalls: also run the joint cases of Clause 2.12. Form 2-1 Design Rainfall Sheet (Cl. 2.13) records: 1. Site coordinates and zone 2. Source, version or access date, export 3. Depth table before and after each factor (steps 3–5) 4. Cross-checks and the CWC floor 5. Hyetographs: table and plot (steps 6–7) 6. AMC and pre- development condition Retention depth (separate route) 90th percentile wet-day (≥ 2.5 mm) 24 h depth, zone value from Annex 2E. No climate factor, no hyetograph for sizing the volume. Cl. 2.10, 2.8.3 Schematic flowchart. Clause numbers refer to Chapter 2. The order of steps 3–5 is the order of the columns of the depth table on Form 2-1.

Figure 2.3 — From design rainfall source to design storm: the steps a designer follows (source, AEPs and durations, point depth, grid-to-point and areal reduction, climate factor, temporal pattern, design storm), the clause that governs each step, what Form 2-1 records, and the separate route for the retention depth. Schematic. Original drawing for this Manual.


2.14 Review and update

2.14.1 The approving authority shall review this chapter every 10 years. It shall also review it within 2 years of any event in which recorded rainfall exceeds the 1% AEP 24-hour or 72-hour design depth at two or more approved gauges in the State.

2.14.2 Updates to NIH-DHAARA take effect for new submittals 6 months after release, unless the authority notifies otherwise.


References (chapter)

Annexes

Annex Content
2A NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map
2B Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule
2C Grid-to-point factors
2D Andhra Pradesh temporal patterns (Huff curves)
2E Retention percentile depths by zone
Form 2-1 Design Rainfall Sheet