Draft v1.0 prepared by NEER. Not adopted by the Government of Gujarat or the Administration of Dadra and Nagar Haveli and Daman and Diu, and has no legal force. About this draft

Gujarat · Draft v1.0

Gujarat Stormwater Design Manual

About this draft

Status. This is Draft v1.0 of the Gujarat Stormwater Design Manual. It was prepared by Neer as a proposed stormwater design standard for Gujarat.

Not adopted. This Manual has not been adopted, notified or endorsed by the Government of Gujarat or by any of its departments, local bodies or agencies, including the Municipal Corporations of Ahmedabad, Surat and Vadodara, the Ahmedabad Urban Development Authority (AUDA) and the other Urban Development Authorities. Where it names a body, such as the Urban Development and Urban Housing Department (UDD), the Narmada, Water Resources, Water Supply and Kalpsar Department (WRD), GSDMA, GWRDC, GCZMA, GIDC, AUDA, a Municipal Corporation, a Municipality or a Nagar Panchayat, it describes the role that body would have if the Manual were adopted. It does not say the body has agreed to that role.

Supplements. The Manual carries one supplement, for a place that adjoins Gujarat but lies outside the State's jurisdiction. Supplement S01 covers the Union Territory of Dadra and Nagar Haveli and Daman and Diu, a single Union Territory since 26 January 2020. Daman and Silvassa lie beside south Gujarat, on the lower Damanganga, and Diu lies off the coast of Saurashtra. The supplement has not been adopted, notified or endorsed by the Administration of the Union Territory or by any of its departments, Planning and Development Authorities, Municipal Councils or agencies. What this notice says of the Manual applies to the supplement.

No legal force. Until a competent authority adopts it, with or without changes, this Manual has no legal force. The development rules, drainage standards and approval conditions in force continue to apply.

Names. Ahmedabad is also written Amdavad. Older sources and some IMD stations keep the old names Baroda (Vadodara), Broach (Bharuch), Bulsar (Valsad) and Kutch (Kachchh); this Manual uses the present names and keeps the old ones where a source or a station uses them. The abbreviation AMC has two meanings in this Manual: in Chapters 2 and 3 it is the antecedent moisture condition; where the text names a body, it is the Ahmedabad Municipal Corporation. The sense is clear from the context.

Use with care. Clauses and values may change after review. Designers remain responsible for their designs and for checking the data they use. Neer accepts no liability for decisions made on the basis of this draft.

Disclosure. Neer publishes the India Flood Atlas, a national map of modelled 1% AEP flood depth. Clause 6.11.3 names it as one example of a regional map that an Approving Authority may adopt for floor levels. The Manual does not require the Atlas; any map adopted under Clause 7.3.4 may be used.

Comments. Comments and corrections are welcome at info@neer.ai.

Preface

Gujarat's cities and towns flood for three reasons. Surat showed all three in August 2006, when releases from the Ukai dam met a high tide in the Tapi; Vadodara showed them in 2019 and again in 2024, and Ahmedabad in July 2026.

  1. Inadequate drain capacity. Drains are too small for the rain they receive, and many cities built them late. Surat had, in its own words, no "full-fledged storm water drainage system" until the 1990s; by 2019 it had about 986 km of drains, along some 70% of its road length. The drains AUDA is now building at Sanand, on the edge of Ahmedabad, are designed for the storm that comes once a year, following the CPHEEO manual. Recent storms are far larger. On 31 July 2019 about 424 mm of rain was reported in six hours at Vadodara, more than three times Baroda's largest six-hour fall in the gauge record of the CWC Flood Estimation Report. In the storm of 22–24 July 2026 the IMD gauge at Ahmedabad recorded 294.6 mm in 24 hours, the fourth-highest total on its record, while AMC's own gauge at Bopal recorded 467.5 mm; 82 of the city's 148 known waterlogging spots flooded, and the city's 42 storm water pumping stations were reported to run at full capacity. Roofs, roads and paving now send more water to the drains, and faster.
  2. Lost storage. Gujarat's towns once held storm water in their talavs and in the floodplains of their rivers, and its coast in creeks, mudflats and mangroves. Much of it has been filled or built over. A study of 1999 counted about 630 lakes within Ahmedabad's civic limits; in 2020 AMC was reported to have 122. In 2002 the Gujarat High Court directed that every lake and pond in the State be notified and protected, never alienated, and recharged by storm water drains. In 2024 the Court found "indiscriminate land filling" of water bodies, which "may also be prime reason for water clogging", and ordered every District Collector to survey them. In Vadodara, an expert committee reported in 2025 that the Vishwamitri's waterways and ravines were being "filled or encroached upon", and the National Green Tribunal has required its floodplain to be demarcated since 2021. In Kachchh, the Comptroller and Auditor General (CAG) found about 117 ha of mangroves destroyed by salt-pan bunds. The water this land used to store now runs into streets and homes.
  3. Blocked outfalls. Surat's drains empty into the Tapi through 42 outfalls, all gated; when the river is in flood the gates are closed, and the city must hold or pump its own rain. In August 2006 the Ukai dam released up to about 907,000 cusec, more than twice the 3.5–4.0 lakh cusec the Tapi through Surat was then reported to carry, on days of high tide; most of the city went under water. Surat's khadis, the tidal creeks that carry much of its storm water, are tide-locked in the same way: they flooded three times in July 2026, and the State announced Rs 500 crore for khadi works. Vadodara's outfall is the Vishwamitri, fed by releases from the Ajwa and Pratappura reservoirs; on 28 August 2024 it rose to 37 ft against a danger mark of about 25 ft. Along the coast, Gujarat has the largest tides in India: INCOIS puts the peak tide at Bhavnagar at 5.22 m above mean sea level, and on 15 June 2023 IMD listed an astronomical tide of 7.54 m at Navlakhi. On the Saurashtra coast, bandharas and tidal regulators built against salinity ingress stand across the mouths of many rivers and set the level that a town drain upstream must discharge against.

A further hazard sits alongside these. Gujarat's coast takes cyclones before and after the monsoon. Cyclone Tauktae crossed the coast near Diu on 17 May 2021, with a storm surge of 3–4 m forecast for Gir Somnath, Amreli and Bhavnagar, and Cyclone Biparjoy crossed near Jakhau in Kachchh on 15 June 2023. Several of the State's heaviest daily falls came outside the monsoon months: 367.7 mm at Naliya on 21 May 1999, 452 mm at Vallabh Vidyanagar on 9 November 1982 and 306.6 mm at Bhavnagar on 18 April 1947. Design for the coast therefore has to cover May and October–November as well as June to September.

National guidance sizes public drains but does not control the runoff that new building adds. This Manual makes stormwater a condition of development approval. Every development above a modest size must:

  • hold frequent rainfall on site;
  • release the large storms no faster than the undeveloped land did, or slower where catchments already flood; and
  • show that its outfall still works when the tide, the khadi or the river is high.

The Manual also sets how public drains, roads, khadis, kaans, talavs and basin-wide master plans are designed, so that private sites and public works aim at the same standard.

The Manual draws on leading stormwater standards from India and abroad. Each is adapted to Gujarat's single south-west monsoon and the cyclones that bracket it, the very heavy rain of the south and the arid north-west, the alluvium of the north and centre, the black cotton soils of the plains and Saurashtra, the sands and saline flats of the coast and the Rann, the talavs and their interlinking, Surat's khadis and Vadodara's kaans, rivers regulated by dams, irrigation canals that receive storm water, and outfalls locked by the largest tides in India.

  1. National base. The CPHEEO Manual on Storm Water Drainage Systems (2019). This Manual builds on it and sets higher standards where it allows a State to do so. IRC road-drainage codes and the NDMA urban flood guidelines are also used.
  2. Overall structure. Kansas City Metro APWA Section 5600 (Version 2025.01), the most recent comprehensive regional standard. It supplies the preserve, retain, detain, convey and maintain sequence and the required retention volume.
  3. Design rainfall. The CWC Flood Estimation Reports for the four subzones that cover Gujarat, as the interim source, and frequency analysis of hourly rainfall by the National Institute of Hydrology (NIH), Roorkee, for climate-change ratios.
  4. Tropical and coastal practice. The PUB Singapore Code of Practice on Surface Water Drainage (7th ed., 2025), for the fixed-coefficient route for small sites, drainage reserves and coastal platform levels. Malaysia's MSMA 2 (2012), for monsoon design storms and simplified on-site detention.
  5. Runoff reduction and treatment. The Georgia Stormwater Management Manual (2016), for runoff reduction and downstream analysis. CIRIA C753 The SuDS Manual (2015), for the treatment train. The Mile High Flood District criteria manual, for outlet and storage design.
  6. Local rules. The Comprehensive General Development Control Regulations, 2017 (CGDCR), which apply across the State; the Gujarat Town Planning and Urban Development Act, 1976, and its Town Planning Schemes; the Gujarat Provincial Municipal Corporations Act, 1949, and the Gujarat Municipalities Act, 1963; the Gujarat Irrigation and Drainage Act, 2013; the High Court's directions of 2002 on lakes and ponds; and the CRZ Notification 2019 as applied in Gujarat through its Coastal Zone Management Plans. This Manual follows them or, where disclosed, makes them stricter.

Why this Manual is needed

India has no uniform stormwater design standard. The CPHEEO Manual on Storm Water Drainage Systems (2019) is the country's first manual dedicated to storm water drainage, but it is advisory. The Ministry of Housing and Urban Affairs lists it among advisory guidelines and treats urban flooding as a matter for State Governments and urban local bodies. None of the national rules or State building rules reviewed for this Manual makes runoff control a condition of building approval. CGDCR has strong rainwater harvesting rules: it requires rainwater harvesting for every building with a ground coverage of 80 m² or more, through percolation pits or percolating wells scaled to plot size; it lets a building unit of more than 4,000 m² provide a retention pond of at least 300,000 litres in place of additional wells; it requires a storage tank on building units of more than 1,000 m²; and it allows no more than half of the open space to be paved. But it sets no release rate and no detention volume, and neither does the Model Building Bye-Laws 2016.

The national documents leave key values open, or give different answers.

  • Return periods. CPHEEO recommends 5 years for drains in Class I cities and 2 years elsewhere, and lets a State committee adopt higher values. A 2023 CPHEEO presentation shows a different table. IRC:SP:50-2013 suggests 1–2 years for urban road drains; IRC:SP:42-2014 suggests 25 years. An engineer designing a drain in Gujarat can cite 1, 2, 5 or 25 years, depending on the code chosen.
  • Detention. CPHEEO describes limiting peak outflow to pre-development rates as general practice. It uses no "shall" and names no storm frequencies.
  • Climate. The NDMA Urban Flooding Guidelines (2010) call for detention and retention facilities and for rainfall curves adjusted for climate change, but give no sizing rule or return period.
  • Design rainfall. No national document gives design rainfall that a designer can apply directly to a given town. Each project chooses its own source. The curves for Ahmedabad and Bhuj in IMD's 2022 national set of rainfall intensity curves appear to repeat a generic curve shared with stations in other States, though Bhuj receives a fraction of Ahmedabad's rain, and the set has no curve for Surat, Vadodara or Rajkot. The reanalysis grids of NIH-DHAARA give 24-hour depths 10–45% below the CWC maps at the cities checked; at Bhuj its 100-year day is 196 mm, against 467.9 mm recorded in 1959.

Gujarat has no drainage design standard of its own. Research for this Manual found no Gujarat design standard, State IDF relationship or circular of UDD or WRD that fixes return periods or design rainfall for urban drains, and no adopted IDF for any city in the State. In particular:

  • current practice designs for frequent storms. The storm drains AUDA is building in Sanand, under an ADB-assisted project, are designed for the storm that comes once a year with a runoff coefficient of 0.7, following the CPHEEO manual, and are routed through Bhadreti lake into the Gota–Godhavi canal. A report on an AMC project says the CPHEEO 5-year storm will be applied. No design intensity was found for Surat, Vadodara or Rajkot;
  • CGDCR does not require on-site detention or limit peak runoff. Its rainwater harvesting rules aim at recharge, and the copy read for this Manual is consolidated only to October 2019, so later amendments have not been checked;
  • there are no flood lines. CGDCR leaves the high flood level to be "decided by Competent Authority", and points to the CWC Flood Atlas for flood-prone land. Its setbacks, 30 m from the bank of an unembanked river, 15 m from a river embankment and 9 m from a talav, canal or nala, are fixed distances, not tied to the flow the channel must carry;
  • the Gujarat Irrigation and Drainage Act, 2013 lets the State notify a river, stream or natural drainage course and prohibit obstructions in it, but no notification for an urban stream was found;
  • the High Court's directions of 2002 on lakes and ponds have not been fully carried out; in 2024 the Court revived them and ordered every District Collector to survey water bodies;
  • storm water is led into irrigation canals, as at Sanand, and no rule was found for how much a canal may take; and
  • Gujarat's Coastal Zone Management Plans under the CRZ Notification 2019 had not been approved when CAG reported in 2022, and no approval was found for this Manual; the plans approved in 2019 and 2020 under the CRZ Notification 2011 remain in force.

So each region and each local body interprets the central manual its own way. The Municipal Corporations, the Municipalities and Nagar Panchayats, the Urban Development Authorities, GIDC, WRD, consultants and funding agencies fill the gaps differently. Two drains on the same street, built by different agencies, can be sized for different storms from different rainfall sources. A drain built to the 1-year storm can empty into a lake or a canal managed by another body to another standard. A drain can be built to empty into a gated outfall, a khadi or a tidal river with no agreed tailwater level. And a reviewer has no common basis against which to check a design.

What this Manual does about it. It turns those open choices into one State standard:

  • one source and method for design rainfall (Chapter 2);
  • named return periods for every drainage element (Chapters 2 and 6);
  • a required pre- versus post-development rule for private sites (Chapter 4);
  • a required tailwater check for outfalls (Chapter 5); and
  • basin-wide master plans, so that neighbouring local bodies plan together (Chapter 11).

It uses the route the CPHEEO manual itself provides: a State may adopt standards higher than the national values (CPHEEO 2019, Table 4.1, Note 2). A Municipal Corporation, a Municipality, a Nagar Panchayat or an Urban Development Authority can still adopt a stricter standard (Chapter 1).

Sources: CPHEEO (2019) Part A §4.4–4.5 and Table 4.1; CPHEEO presentation to CSE (August 2023); IRC:SP:50-2013 §6; IRC:SP:42-2014 §6; NDMA (2010) Urban Flooding Guidelines; MoHUA Model Building Bye-Laws (2016); Lok Sabha Unstarred Question 1847 (July 2026); UD&UHD, Comprehensive General Development Control Regulations 2017, as modified up to October 2019, Regulations 2.55, 13.1.3, 17.1, 17.2.2 and 17.2.3 and Part II use-zone conditions; Gujarat Irrigation and Drainage Act, 2013 (Act 6 of 2013), s.11; Gujarat High Court, Shailesh R. Shah v. State of Gujarat, 2002 (3) GLH 642, para 24, as quoted in Lakhabha Bhojabha Manek v. Ashok M. Sharma, R/MCA (Contempt) 1903 of 2023 in R/WP (PIL) 144 of 2021 (1 August 2024); ADB/AUDA, Initial Environmental Examination, Stormwater Drainage System in Sanand (draft, February 2023); JICA, report on an AMC project (secondary); SMC, Storm Water Drainage Action Plan 2019; SANDRP, Surat floods (22 August 2006), compiling CWC and CEA bulletins; CAG, Report No. 3 of 2022 (Government of Gujarat), Conservation and Management of Coastal Ecosystems; CAG, Gujarat Civil Report 2010, para 1.1; IMD, Extremes of Temperature and Rainfall for Indian Stations (up to 2012); Das et al. (2022), MAUSAM 73(4); NIH-DHAARA (accessed 1 November 2026); CWC, Flood Estimation Reports for Subzones 3(a), 1(a), 3(b) and 5(a); INCOIS (2025), extreme sea levels (TR-04); IMD, Cyclone Biparjoy bulletin (15 June 2023) and Cyclone Tauktae bulletins (17 May 2021); RMSI bulletin on the Vadodara floods (2019); Citizen Matters (19 October 2020); Counterview (September 2025); The Wire Science (29 May 2021); DeshGujarat (27 August 2024; 9 July, 23–24 July and 18 August 2026).


How to use this Manual

Clauses and commentary. Numbered clauses (for example 4.5.2) are the requirements of this Manual and use "shall". Paragraphs headed Commentary explain the reason for a clause and cite its precedent. They are guidance, not requirements. Where a value has no direct precedent elsewhere, the commentary says so and explains why this Manual sets it.

Return periods. Storms are described both by annual exceedance probability (AEP) and by return period. For example, "1% AEP (100-yr)" means a storm with a 1-in-100 chance of being equalled or exceeded in any year.

Illustrative values. Worked examples and figures marked "Illustrative — not design values" show method and scale only. Design values come from the sources set in Chapter 2.

Annexes and forms. Each chapter lists the annexes and forms it relies on. They follow the chapters, grouped by chapter, and hold the forms to submit, worked examples, templates, model text and standard drawings. Annexes that need data not yet collected are marked To be prepared. They say what they will contain, and the clause that depends on them states the rule that applies in the meantime.

Supplements. The supplement follows the annexes. It applies the Manual to the Union Territory of Dadra and Nagar Haveli and Daman and Diu, which adjoins Gujarat, and states where its rules differ.

Figures. All figures are original drawings prepared for this Manual. Where a figure follows a published concept, its caption credits the source.

Where to start.

If you are… Read first
A developer or architect Chapter 1 (does it apply?), Chapter 4 (what to provide), Chapter 10 (what to submit)
A design engineer Chapters 2–6, then 8 and 9
A local body or approving authority Chapters 1, 10 and 11
A planner or waterbody manager Chapters 7 and 11

Contents

Ch Title Annexes and forms
1 Policy, Applicability and Adoption Annexes 1
2 Design Rainfall and Design Storms Annexes 2
3 Hydrologic Methods Annexes 3
4 Site Runoff Control: Retention and Detention Annexes 4
5 Downstream and Tailwater Analysis Annexes 5
6 Minor and Major Drainage Systems Annexes 6
7 Waterbodies, Tanks (Talavs) and Setbacks Annexes 7
8 Water Quality and Recharge Annexes 8
9 Hydraulic Design of Structures Annexes 9
10 Submittals, Review, Operation & Maintenance and Enforcement Annexes 10
11 Basin and City Stormwater Master Plans Annexes 11

Supplements

No. Title Status
S01 Dadra and Nagar Haveli and Daman and Diu (Union Territory) Not adopted by the Administration of the Union Territory

List of tables

TableTitle
1.1Differences between Tier A and Tier B authorities
1.2Policy supplement: adoptable alternatives S-1 to S-5
1.3Relationship with other instruments
1.4Roles and responsibilities under this Manual
2.1Design return periods (summary)
2.2Interim climate factors
2.3Illustrative scale of the mixed-frequency rule (not design values)
3.1Permitted hydrologic methods
3.2Runoff coefficient C (for AEP of 10% or more frequent)
3.3Frequency factor Cf
3.4Manning's n for sheet flow (USDA SCS TR-55, 1986, Table 3-1)
3.5Runoff curve numbers, AMC II, Ia = 0.2S (USDA SCS TR-55, 1986, Tables 2-2a and 2-2c)
4.1Design storms to be routed for detention sizing
4.2Illustrative example: peak discharges and storage used, by duration (Illustrative — not design values)
4.3Tier B permissible site discharge and site storage requirement (template)
4.3AFixed release coefficients (provisional)
5.1Design tailwater levels for tidal outfalls
5.2Joint-probability cases for tidal and riverine outfalls
6.1Design AEPs for conveyance (matches Clause 2.4)
6.2Street flow limits
6.3Flow hazard limits for streets and overland flow paths
6.4Combined flood hazard vulnerability classes (reproduced for reference)
6.5Inlet clogging factors (share of clean capacity assumed lost)
6.6Manning's n for design (from CPHEEO 2019)
6.7Minimum freeboard in open and covered drains
6.8Maximum spacing of manholes on straight pipe runs
6.9Minimum drainage reserve width (adopted from PUB Singapore)
7.1Fixed-width setback where no 1% AEP extent is available
8.1Pollutants of concern, sources and primary controls
8.2Required Level of Service for sites that are not redevelopment
8.3BMP Value Ratings and suitability in Gujarat
9.1Entrance loss coefficients ke (outlet control, full or partly full)
9.2Maximum permissible mean velocities in channels
9.3Riprap classes and apron dimensions (HEC-14)
9.4Minimum internal size of manholes
9.5Minimum IS 456 exposure classes for Gujarat locations
10.1Submittal stages and linked approvals
10.2Forms used in submittals
10.3Minimum owner inspection frequencies
10.4Graduated enforcement response
11.1Minimum data and surveys for a BSMP
11.2Minimum levels of service
1A.1Tier A authorities as defined in Clause 1.6.1
1A.2Register of Tier A authorities (layout)
1B.1Flood-sensitive catchments listed in Clause 4.5.3.2
1B.2Attributes of the flood-sensitive catchment layer (layout)
1C.1Alternatives adopted by this resolution
1D.1Schedule: alternatives adopted (layout)
2A.1Benchmark comparison of design depths (layout)
2A.2Rainfall zones (layout)
2B.1Ratios P(t)/P(24h) by zone (layout)
2B.2Fixed-interval adjustment factors (Clause 2.6.3)
2C.1Grid-to-point factors (layout)
2D.1Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)
2E.1Retention depth P_R by zone (layout)
3A.1Soil series to HSG lookup (layout)
3A.2Seasonal high water table, by mapping unit (layout)
3B.1Supplementary land covers, AMC II (layout)
3B.2CN calibration catchments (layout)
3C.1Problem 3C-1 solution
3C.2Problem 3C-2 solution
3C.3Problem 3C-3 solution
3C.4Problem 3C-4 solution
3C.5Problem 3C-5 stage–storage–discharge relationship
3C.6Problem 3C-5 routed outflow
3C.7Benchmark results to be reported by the applicant
3D.1Calibrated peak rate factors (layout)
3E.1SUH relationships by subzone (layout)
3E.2Worked example outline (layout)
4A.1Attributes of the shallow-groundwater zone layer (layout)
4B.1Contents of Annex 4B and their status
4B.2Tier B PSD and SSR (layout of Table 4.3)
4B.3Retention credit factor C_R (layout)
4B.4Largest orifice diameter (mm) for a permissible discharge at a given head (Cd = 0.60, free discharge)
4B.5Fixed release coefficients C_10 and C_2 (provisional, Table 4.3A)
4C.1Inputs (Illustrative — not design values)
4C.2Design rainfall depths, mm (Illustrative — not design values)
4C.3Curve numbers and abstractions (Illustrative — not design values)
4C.4Storm runoff depth Q, mm (Illustrative — not design values)
4C.5Unit hydrograph parameters (Illustrative — not design values)
4C.6Stage–storage–discharge, trial outlet (Illustrative — not design values)
4C.7Routing of the 100-yr 72-hour storm through the trial outlet, around the peak (Illustrative — not design values)
4C.8Routing of the 100-yr 72-hour storm through the trial outlet, hourly (Illustrative — not design values)
4C.9Results for the trial outlet (120 mm and 470 mm orifices) (Illustrative — not design values)
4C.10Stage–storage–discharge, revised outlet (Illustrative — not design values)
4C.11Results for the revised outlet (170 mm and 460 mm orifices) (Illustrative — not design values)
4C.12Retention credit by routing, revised outlet (Illustrative — not design values)
4C.13Outlet checks, revised outlet (Illustrative — not design values)
4C.14Summary of the revised design (Illustrative — not design values)
5A.1Use of the Annex 5A values in the design tailwater (Table 5.1)
5A.2Tidal datums, surge and still-water levels by coastal segment (layout)
5B.1Water bodies named in Chapter 5
5B.2Attributes of the Annex 5B layers (layout)
5C.1Inputs (Illustrative — not design values)
5C.2Outfall-closed check results (Illustrative — not design values)
5C.3Volume balance, 1% AEP 48-hour storm, Run B (Illustrative — not design values)
5C.4Stage hydrograph, 1% AEP 48-hour storm, Run B (Illustrative — not design values)
5C.5Summary (Illustrative — not design values)
6A.1Interim requirements for inlets until Annex 6A is published (from Chapters 6 and 9)
6A.2Register of standard inlet types (layout)
6A.3Capacity on grade (layout; one table per inlet type)
6A.4Capacity in a sag (layout; one table per inlet type)
6B.1Sediment allowances already set by Chapter 6 (provisional, to be calibrated)
6B.2Sediment yield by land use and drain type (layout)
6B.3Calibration of the sediment allowance (layout)
6C.1Dimensions on the standard drawings and their source clauses
7A.1Attribute fields of the waterbody inventory (WB_POLY)
7A.2Code lists
7A.3Attribute fields of structures (WB_STRUCT)
7B.1Fixed-width setback by waterbody class (alternative S-3)
7B.2Source buffers cited in Clause 7.4.6 (KC APWA 5600, 2006, §5605.3)
7C.1Rule levels by period (to be completed for each tank)
7C.2Outlet settings by level (to be completed for each tank)
7C.3Triggers and actions (to be completed for each tank)
7D.1Hold points for desilting and restoration works
7E.1Waterbodies and land
7E.2Parts of a waterbody and its system
7E.3Management and statutory terms
7E.4Terms not yet verified
8A.1Water quality rainfall depths by zone (layout)
8A.23-month ARI intensity by duration (layout)
8B.1Required LoS for redevelopment (layout)
8B.2Worked example: composite VR (illustrative)
8B.3Composite VR of treatment trains (layout)
8C.1Monitoring site register (layout)
8C.2Event record (layout; parameters of Clause 8.13.2)
8C.3Performance summary and proposed VR (layout)
8D.1Pretreatment (all BMPs)
8D.2Bioretention and rain gardens (Figure 8.2)
8D.3Vegetated swales
8D.4Vegetated filter strips
8D.5Permeable pavement
8D.6Infiltration trenches and basins (Figure 8.3)
8D.7Wet ponds (extended wet detention)
8D.8Constructed wetlands
8D.9Gross pollutant traps and outfall screens
8D.10Oil-grit separators
8D.11Infiltration and recharge criteria (all infiltrating BMPs)
8D.12Bioretention filter media and layers
8D.13Indicative plants for bioretention, swales and filter strips
8D.14Indicative plants for constructed wetlands and wet ponds
8D.15Species not to be planted
8E.1Selection of measures (Clause 8.12.3)
8E.2ESC timing and inspection (Clauses 8.12.2 and 8.12.5)
9A.1HDS-5 inlet-control coefficients for common inlets
9A.2Inputs for the worked example
9A.3Critical depth and specific head (D = 1.2 m)
9A.4Inlet-control headwater
9A.5Outlet-control headwater
9A.6Governing headwater and checks
9A.7Riprap apron sizing
9A.8Summary of the worked example (Illustrative — not design values)
9B.1Dimensions and rules on the standard drawings and their source clauses
9C.1Pump station design checklist
9C.2Control levels (values to be set in design)
10A.1Calculator inputs
10A.2Calculations the calculator shall perform
10B.1Layers
10B.2Attributes of SW_FAC (facilities)
10B.3Attributes of SW_OUTF (outfalls)
10B.4Attributes of SW_CATCH (catchments)
10B.5Attributes of SW_FLOW and SW_CONV (flow paths and conveyance)
10B.6Metadata (SW_META)
10B.7Facility type codes (FAC_TYPE)
10B.8Status codes (STATUS)
10B.9Inspection result codes (INSP_RES)
10C.1Access dimensions set by the Manual
10C.2Access dimensions not set by the Manual (to be confirmed in design)
10D.1Contents of an O&M plan
10D.2Retention and infiltration (soakaways, trenches, bioretention, permeable paving)
10D.3Surface detention basin or multi-use common plot area
10D.4Underground or podium detention tank, gravity outlet
10D.5Pumped detention, pumps and controls
10D.6Flap or tide gate, non-return valve
10D.7Gross pollutant trap or first-flush device
10D.8Private drains and inlets
11A.1Deliverables
11B.1Basins named in Clause 11.3.3 (provisional)
11B.2Attributes of the basin boundary layer (layout)
11C.1Depth–damage curve (layout, one table per building type)
11D.1Items to be published
S1.1Modifications to the Manual for the Union Territory
S1.2Roles in the Union Territory

List of figures

FigureTitle
1.1Stormwater management hierarchy
1.2Applicability decision flowchart
2.1Design rainfall source hierarchy and adjustments
2.2Design hyetographs
2.3From design rainfall source to design storm
3.1Selection of hydrologic method
3.2Time of concentration: flow segments along the longest flow path (schematic)
3.3SCS-CN runoff depth versus rainfall depth
3.4Two-step continuous simulation: starting tank level (schematic)
3.5Pre- and post-development hydrographs
4.1Pre-development 10-yr, post-development 100-yr uncontrolled, and detained hydrographs (illustrative)
4.2Detention storage stack and multi-stage outlet (schematic)
4.3Fixed-coefficient route: release caps, storage by the mass-curve method and two-stage outlet (schematic)
5.1Extent of downstream analysis
5.2Tidal outfall section with flap gate and design tailwater levels
5.3Tide-locked outfall timeline (illustrative)
6.1Minor and major drainage in a kerbed street
6.2Gutter spread, inlet interception and clogging
6.3Drain sections: freeboard, sediment allowance and access
6.4Drainage reserve: cross-section (schematic)
6.5Coastal band: floor level stack and extent of the band (schematic)
7.1Waterbody setback zones
7.2Compensatory storage by elevation band (schematic)
7.3Talav chain to a canal and the river: the Ahmedabad pattern
8.1Treatment train
8.2Bioretention cell
8.3Infiltration trench
9.1Culvert hydraulics: inlet control and outlet control
9.2Riprap apron at a pipe or culvert outlet (schematic)
9.3Stormwater pump station: wet well, screens, levels and outfall
10.1Submittal, review and approval workflow
10.2Construction hold points from approval to handover
10.3Maintenance cycle and responsibility
11.1Basin master plan process
11.2BSMP model schematic
6C.1Covered roadside drain with removable covers
6C.2Access and junction chamber on a covered drain
6C.3Kerb inlet with silt sump
8E.1Silt fence: section and plan (schematic)
8E.2Sediment basin with surface dewatering outlet: section (schematic)
8E.3Stabilised construction exit: plan and section (schematic)
8E.4Drain inlet protection (schematic)
9B.1Culvert headwalls, wingwalls and cut-off walls
9B.2Straight vertical drop structure
9B.3Trash rack at a conduit entrance
9B.4Detention outlet riser and emergency spillway

Abbreviations

Abbreviation Meaning
ADB Asian Development Bank
AEP Annual exceedance probability
AMC Antecedent moisture condition (Chapters 2 and 3); Ahmedabad (Amdavad) Municipal Corporation (where a body is named)
AMRUT Atal Mission for Rejuvenation and Urban Transformation
APWA American Public Works Association
ARF Areal reduction factor
AUDA Ahmedabad Urban Development Authority
BSMP Basin Stormwater Master Plan
CAG Comptroller and Auditor General of India
CD Chart datum
CGDCR Comprehensive General Development Control Regulations, 2017 (Gujarat)
CGWB Central Ground Water Board
CN Curve number (SCS/NRCS method)
CPHEEO Central Public Health and Environmental Engineering Organisation
CRZ / CZMP Coastal Regulation Zone / Coastal Zone Management Plan
CSE Centre for Science and Environment
CWC Central Water Commission
DDCZMA Daman and Diu Coastal Zone Management Authority
DDMA District Disaster Management Authority
DNH Dadra and Nagar Haveli
DP Development Plan (GTPUD Act)
ESL Extreme sea level
FER Flood Estimation Report (CWC)
FRL Full reservoir level
FTL / MWL Full tank level / maximum water level
GCZMA Gujarat Coastal Zone Management Authority
GDR General Development Rules (Dadra and Nagar Haveli and Daman and Diu)
GIDC Gujarat Industrial Development Corporation
GIDM Gujarat Institute of Disaster Management
GPCB Gujarat Pollution Control Board
GPMC Act Gujarat Provincial Municipal Corporations Act, 1949
GSDMA Gujarat State Disaster Management Authority
GTPUD Act Gujarat Town Planning and Urban Development Act, 1976
GWRDC Gujarat Water Resources Development Corporation
GWSSB Gujarat Water Supply and Sewerage Board
HAT / MHWS Highest astronomical tide / mean high water springs
HFL High flood level
HGL Hydraulic grade line
HSG Hydrologic soil group
HTL High tide line
IDF Intensity–duration–frequency
IMD India Meteorological Department
INCOIS Indian National Centre for Ocean Information Services
IRC Indian Roads Congress
MoHUA Ministry of Housing and Urban Affairs
MSL Mean sea level
NDMA National Disaster Management Authority
NGT National Green Tribunal
NIH National Institute of Hydrology, Roorkee
PDA Planning and Development Authority (Dadra and Nagar Haveli and Daman and Diu)
PSD Permissible site discharge
RMC Rajkot Municipal Corporation
RRV Required retention volume
RWH Rainwater harvesting
SEOC State Emergency Operation Centre, Gujarat
SLA Sea-level allowance
SMC Surat Municipal Corporation
SRFDCL Sabarmati River Front Development Corporation Limited
SUDA Surat Urban Development Authority
SW monsoon / JJAS South-west monsoon, June–September
SWD Storm water drain
TP scheme Town Planning Scheme (GTPUD Act)
UDA Urban Development Authority (GTPUD Act)
UDD Urban Development and Urban Housing Department, Gujarat
ULB Urban local body (a Municipal Corporation, a Municipality or a Nagar Panchayat)
UT Union Territory
VMC Vadodara Municipal Corporation
VUDA Vadodara Urban Development Authority
WQv Water quality volume
WRD Narmada, Water Resources, Water Supply and Kalpsar Department, Gujarat