Chapter 7Waterbodies, Tanks (Keres) and Setbacks
7.1 Purpose and scope
7.1.1 This chapter treats waterbodies as part of the drainage system. It sets the rules for:
- (a) identifying and mapping every waterbody that a development or public work affects;
- (b) the setback zones around waterbodies, and the uses allowed in each zone;
- (c) fill in flood-prone land, and the compensatory storage needed where fill is allowed;
- (d) counting tank (kere) storage, including tank cascades, as design storage;
- (e) restoring and desilting tanks and ponds;
- (f) protecting supply channels, surplus courses, inlets and outlets;
- (g) wetlands, marshes and estuaries, including the Bellandur–Agara–Varthur system, the Ramsar tanks Magadi Kere and Ankasamudra, and the Aghanashini estuary;
- (h) the interface with encroachment and its removal;
- (i) fee-in-lieu contributions to regional tank storage (with Chapter 4); and
- (j) the safety of tank bunds and other embankments.
7.1.2 This chapter applies to every development and public work to which this Manual applies under Chapter 1 and that:
- (a) adjoins a waterbody or lies wholly or partly within its setback (Clause 7.4);
- (b) discharges to a waterbody, directly or through a drain, within the downstream analysis extent of Chapter 5; or
- (c) alters a waterbody, its bund, sluice, surplus weir, supply channel or surplus course.
7.1.3 Where a statute or statutory rule sets a wider setback or a stricter restriction, the statute governs (Clause 1.3.3). Nothing in this chapter authorises any work that the Karnataka Tank Conservation and Development Authority Act, 2014 (as amended by Karnataka Act No. 15 of 2018 and Karnataka Act No. 19 of 2026), the zoning regulations made under the Karnataka Town and Country Planning Act, 1961, including UDD 468 MNJ 2025(E), the Coastal Regulation Zone Notification, 2019, or any other law, prohibits.
7.2 Definitions
| Term | Meaning in this Manual |
|---|---|
| Waterbody | A river (hole), stream or nala (halla), canal or channel (kaluve), rajakaluve (primary, secondary or tertiary storm drain), tank (kere), small tank or pond (kunte or katte), village pond (honda), stepped or temple tank (kalyani or pushkarini), lake, marsh (jaugu), estuary or river mouth (alive), backwater or tidal creek, supply channel or surplus course, perennial or seasonal (as in Chapter 1). |
| Tank (kere) | A waterbody impounded by an earthen bund, fed by its own catchment and/or a supply channel, with a surplus weir and one or more sluices. |
| Tank cascade | A chain of tanks in which the surplus or sluice outflow of one tank feeds the next (as in Chapter 3). |
| Full tank level (FTL) | The crest level of the surplus weir (kodi) of a tank, or the permanent crest of its regulating structure. The tank holds water up to FTL without spilling. |
| Maximum water level (MWL) | The highest water level in a tank when the surplus weir passes the tank's design flood. For this Manual, it is the greater of the level recorded by the Minor Irrigation Department and the level computed for the 1% AEP (100-yr) inflow with the climate factor of Clause 2.8 (Clause 7.7.4). |
| Top bund level (TBL) | The crest level of the tank bund. |
| Waterspread | The area of a tank submerged at FTL. |
| Foreshore | The land around a tank between the FTL contour and the MWL contour. Foreshore land is flooded whenever the tank surpluses, and is part of the tank's flood storage. |
| Supply channel (kaluve) | A channel that brings water from a river, anicut or upstream tank into a tank. |
| Surplus course | The channel that carries the overflow of a surplus weir to the next tank, a river, a drain or the sea. |
| Sluice (tubu) | A controlled outlet through a tank bund, usually to an irrigation channel. |
| Top of bank | For a channel, the break in slope at the edge of the channel. Where it cannot be identified, the edge of the water surface at the 50% AEP (2-yr) flow. |
| 1% AEP flood extent | The land flooded by the 1% AEP (100-yr) flood with the climate factor of Clause 2.8, from a hydraulic model that meets Chapter 3 and Chapter 5, or from a map adopted by the Authority under Clause 7.3.4. |
| Floodway | The waterbody and the adjoining land that must be kept free of obstruction to pass the 1% AEP flood without raising the 1% AEP water level by more than 0.1 m at any point (Clause 7.6.1). For a tank, all land below MWL. |
| Flood fringe | The part of the 1% AEP flood extent outside the floodway. |
| Zone 1 (waterbody protection zone) | The inner setback zone defined in Clause 7.4.3. |
| Zone 2 (flood fringe setback) | The outer setback zone defined in Clause 7.4.4. |
| Setback | Zone 1 and Zone 2 together. |
| Compensatory storage | Excavated storage that replaces flood storage lost to fill, under Clause 7.6.4. |
| Flood cushion | Storage below FTL kept empty, under a documented operating rule, to absorb a flood (Clause 7.8). |
Karnataka terms. The following terms are used in this chapter in addition to those above (see also Annex 7E):
| Term | Meaning in this Manual |
|---|---|
| Kere | A tank: a waterbody impounded by an earthen bund (ēri or katte), with a surplus weir (kodi) and one or more sluices (tubu). The Manual's term "tank" includes every kere, and every waterbody that section 2(1)(g) of the KTCDA Act, 2014 calls a tank, pond or lake: one "mentioned in revenue records as sarkari kere, kharab kere, kunte, katte or by any other name", whether or not it holds water. |
| Kunte, katte | A small tank or pond. Kunte is also a measure of land, and katte also means a bund; neither shall be read in that sense in an area statement for a waterbody. |
| Kodi | The surplus weir of a tank. Its crest is FTL (Clause 7.2). The channel below it is a surplus course, and in Bengaluru usually a rajakaluve. |
| Rajakaluve | A storm water drain that is, or was, the link between tanks. UDD 468 MNJ 2025(E) defines, from the revenue records, a primary drain as one leading from a lake to another lake or to a river, a secondary drain as one leading to a lake or a primary drain, and a tertiary drain as one leading to a secondary drain. Every rajakaluve is a surplus course or supply channel for Clause 7.10, and a natural channel for Clause 7.4.1(b). |
| Revenue boundary of a tank | The boundary of the tank land in the Revenue records, from which the buffer of section 12(3) of the KTCDA Act, 2014 (as substituted by Act 19 of 2026) is measured. Setbacks under Clause 7.4 are measured from the larger of that boundary and the surveyed FTL (Clause 7.13.1). |
| FTL and MWL in the KTCDA Act | Section 12(2), as substituted in 2026, uses "Full Tank Level" and "Maximum Water Level" without a definition that was found. For this Manual the definitions of Clause 7.2 apply, and the band between them is foreshore and floodway (Clause 7.6.1). |
| Minor Irrigation Department | The Minor Irrigation and Ground Water Development Department, which holds tanks with a command of up to 2,000 ha, including, since Karnataka Act No. 15 of 2018, the tanks in municipal corporations. Tanks with a larger command are outside the KTCDA Act and are held by the WRD; for them, references in this chapter to the Minor Irrigation Department mean the WRD. |
| Valley zone | Land shown as valley in the zoning regulations of the Revised Master Plan 2015 for Bengaluru, in which "fresh permissions for developments shall not be accorded". For this Manual it is flood fringe at least, and the 1% AEP extent shall be determined for any site in it (Clause 7.3.4(c)). |
| Kalyani | A stepped tank, usually square and often in a temple. It is a waterbody for this chapter, and its storage may be counted only under Clause 7.7. |
7.3 Inventory and mapping of waterbodies
7.3.1 Statewide inventory. The Authority, with the Minor Irrigation Department and the Revenue Department, shall maintain a GIS layer of every waterbody in its area (Annex 7A). For each waterbody it shall record:
- (a) its type (Clause 7.2), name and survey numbers;
- (b) its custodian (the Minor Irrigation Department, the GBA or a city corporation, the ULB, the BDA, the Forest Department, the Gram Panchayat, a temple or another body);
- (c) its boundary as recorded in Revenue records;
- (d) for tanks: FTL, MWL, TBL, the surplus weir crest length and type, sluices, the supply channel and the surplus course, each with its datum;
- (e) its position in any tank cascade, with the upstream and downstream tanks;
- (f) the 1% AEP flood extent, where mapped; and
- (g) known encroachments, with the date recorded.
7.3.2 Project mapping. Every drainage report shall include a Waterbody Sheet (Form 7-1) showing all waterbodies:
- (a) within the site;
- (b) within 100 m of the site boundary; and
- (c) downstream, to the extent of the downstream analysis of Chapter 5.
The sheet shall show, on a plan at a scale of 1:1,000 or larger for (a) and (b):
- the Revenue record boundary;
- the surveyed FTL or top of bank;
- the MWL contour (tanks) and the 1% AEP flood extent;
- Zone 1 and Zone 2 (Clause 7.4); and
- every supply channel, surplus course, sluice and surplus weir.
7.3.3 Sources. Waterbodies shall be identified from all of the following. Where they conflict, the larger waterbody extent governs:
- (a) Revenue village maps and survey records, including the tank land recorded as sarkari kere, kharab kere, kunte or katte, and the kharab land recorded for kaluves and rajakaluves, from which UDD 468 MNJ 2025(E) classes drains and measures their buffers "as per revenue records";
- (b) Minor Irrigation Department and Gram Panchayat tank registers and records of FTL and MWL;
- (c) the Authority's inventory (Clause 7.3.1) and any list published under court directions;
- (d) historical topographic maps and satellite imagery, including the ISRO National Wetland Inventory and Assessment; and
- (e) a site survey by a licensed surveyor, levelled to the datum stated in Clause 7.3.5.
7.3.4 Flood extent maps. The Authority may adopt 1% AEP flood extent or flood depth maps for its area. A depth map adopted under this clause also sets floor levels under Clause 6.11. Where a map has been adopted, it shall be used unless a site hydraulic study under Chapters 3 and 5 shows a larger extent. Where no map has been adopted, the Applicant shall determine the 1% AEP extent by a hydraulic study for:
- (a) any site in a flood-sensitive catchment (Chapter 1);
- (b) any site of 1 ha or more adjoining a waterbody; and
- (c) any site where the Authority so requires.
For other sites, the fixed-width setback of Clause 7.4.6 may be used.
7.3.5 Datum. All levels in this chapter shall be stated to one datum, stated on every drawing. Where Minor Irrigation Department records use a local or older datum, the conversion to the project datum shall be surveyed and stated.
Commentary. The census record is not a reliable guide to what exists in the towns: it lists only 789 urban water bodies in Karnataka and no urban encroachment at all (1st Census of Water Bodies; Rajya Sabha, 16 December 2024), so census status is not proof that a waterbody is intact. Drain records conflict as well. The CAG found that the RMP 2015 and the Bengaluru drains master plan "deprived the planners of a single source of truth", that drains shown as primary and secondary on the city's map were shown as secondary and tertiary in the draft RMP 2031, that no record of tertiary drains was kept, and that none of the drains it test-checked had boundary marks (CAG, Report No. 2 of 2021). Since UDD 468 MNJ 2025(E) classes drains and measures their buffers from the revenue records, the class of a drain is itself a matter of record that the Waterbody Sheet must show. The RMP 2015 zoning regulations already direct that, where a buffer has not been marked "due to cartographical error", the buffer "based on the revenue records" shall be insisted on without reference to the land use plan. No 1% AEP flood map at a scale usable for a site setback was found for any town in the State. The city has identified 201 to 209 flood-prone locations with KSNDMC (Citizen Matters, 2025; The News Minute, 2025), and UDD 235 MNJ 2025(E) bars basements in flood-prone and low-lying areas "as notified by the competent authority", but no method of notifying such areas was found. Clause 7.3.4 lets the Authority adopt flood maps once they are issued; until then, the Applicant must produce the extent for larger and flood-sensitive sites. Whether any Karnataka wetland has been notified under the Wetlands (Conservation and Management) Rules, 2017 was not confirmed. Clause 7.3.3 makes the larger of the recorded and surveyed extents govern, because the Revenue boundary and the surveyed water edge often differ, and either may have been reduced by encroachment. The 100 m search band in Clause 7.3.2 is set by this Manual.
7.4 Setbacks
7.4.1 Waterbodies to which setbacks apply. Setbacks apply to:
- (a) every waterbody recorded under Clause 7.3.1 or found under Clause 7.3.3, whatever its size; and
- (b) every natural channel, whether recorded or not, that drains 8 ha or more at the site.
7.4.2 Two zones. The setback has two zones, shown in Figure 7.1:
- Zone 1 (waterbody protection zone), next to the waterbody; and
- Zone 2 (flood fringe setback), outside Zone 1.
7.4.3 Zone 1 width. Zone 1 is measured outward from the FTL contour (tanks, lakes and ponds) or from the top of bank (channels). Where both apply, use whichever gives the wider zone. Zone 1 extends to the greatest of:
- (a) 15 m, the maintenance-strip minimum set by this Manual, which is wider than the statutory buffer of most Karnataka tanks and drains (see the Disclosure below);
- (b) the outer edge of the floodway (Clause 7.6.1); and
- (c) for a tank, the MWL contour.
7.4.4 Zone 2 width. Zone 2 extends from the outer edge of Zone 1 to the 1% AEP flood extent plus 10 m. Where the 1% AEP flood extent lies inside Zone 1, Zone 2 is 10 m wide.
7.4.5 Statutory and approval setbacks. Where a statute, a statutory rule, a condition of planning permission or a Minor Irrigation Department NOC or KTCDA approval sets a setback wider than Zone 1 or Zone 2, the wider setback governs for the uses it restricts.
7.4.6 Fixed-width setback where no 1% AEP extent is available. Where Clause 7.3.4 does not require a hydraulic study and no map has been adopted, the setback (Zone 1 plus Zone 2) shall be not less than the following, measured as in Clause 7.4.3:
Table 7.1 — Fixed-width setback where no 1% AEP extent is available
| Waterbody | Total setback (Zone 1 + Zone 2) | Of which Zone 1 |
|---|---|---|
| Channel draining 8 ha to 65 ha | 25 m | 15 m |
| Channel draining 65 ha to 20 km² | 40 m | 15 m |
| Channel draining more than 20 km², and rivers | 50 m | 20 m |
| Tank, lake or pond | MWL contour + 25 m | to MWL contour, and not less than 15 m from FTL |
| Marsh, estuary or backwater | as notified by the Authority, and not less than 50 m | 15 m |
This table is the alternative S-3 of the Policy Supplement (Annex 1C) and may be adopted under Clause 1.7.
7.4.7 Minimum in all cases. No setback under this chapter, and no variance under Clause 1.10, shall reduce Zone 1 below 15 m (Clause 1.10.3(c)).
Commentary. The 15 m minimum is set by this Manual as a maintenance strip, and is not a statutory figure. The buffers now in force are graded by tank size, from 0 m to 30 m from the revenue boundary of the tank (section 12(3) of the KTCDA Act, 2014, as substituted by Karnataka Act No. 19 of 2026), and, in the Bengaluru Metropolitan Region only, 15 m, 10 m and 5 m from the edge of primary, secondary and tertiary drains (UDD 468 MNJ 2025(E)). Where one of them is wider than Zone 1, it governs under Clause 7.4.5 (see the Disclosure below). Extending the setback to the mapped 1% AEP extent plus a margin follows the Kansas City Metro APWA Section 5600 (2025.01) two-zone structure:
- APWA Zone 1 (streamside) is measured from top of bank, and only utility and road crossings are allowed in it.
- APWA Zone 2 is the 1% AEP flood extent plus 10 ft (about 3 m), for streams draining 20–40 acres.
- APWA lowered the trigger for stream setbacks from 40 acres to 20 acres (about 8 ha) in 2025.01.
(MARC, APWA 5600 Policy Supplement, Nov 2025.) Clause 7.4.1(b) adopts the 8 ha trigger. This Manual's 10 m margin is wider than APWA's 10 ft and has no direct precedent. This Manual sets it because Karnataka flood maps are mostly coarser than US maps, the ground on the coastal plain is very flat (so a small error in level moves the flood edge a long way), and the margin gives room for maintenance access along the waterbody.
The fixed-width table in Clause 7.4.6 is set by this Manual. Its channel widths are scaled from the 2006 APWA default stream buffers, which were 40 ft, 60 ft, 100 ft and 120 ft (12, 18, 30 and 37 m) for drainage areas of less than 40 acres, 40–160 acres, 160–5,000 acres and more than 5,000 acres (KC APWA 5600, 2006, §5605.3). They are rounded up and floored at the 15 m minimum. APWA offered a fixed-width table for the same reason: communities objected that the 1% extent is often unmapped for small drainage areas (MARC Supplement, 2025). The table should be replaced by mapped extents as soon as the Authority adopts them.
URDPFI (2015) reserves the area flooded at a 10-year frequency for parks and playgrounds, and allows residential use in the 25-year flood zone only on stilts, with minimum plinth levels and no basements. This chapter is stricter. It keeps habitable buildings out of the whole 1% AEP extent plus margin, because the 1% AEP (100-yr) event is the major-system standard of this Manual (Chapter 6).
Karnataka's statutory waterbody buffers were cut in 2025 and 2026, and are now smaller than every earlier figure. Tanks, statewide: section 12(3) of the KTCDA Act, 2014, as substituted by Karnataka Act No. 19 of 2026 (assent 16 February 2026; in force on publication, 18 February 2026), bars construction and commercial, recreational or industrial activity within a buffer measured "from revenue boundary of the tank" and graded by the area of the tank, as in the table below. Public utilities (roads, bridges, electrical and water supply lines, underground drainage lines, pump houses, sewage treatment plants, intermediate sewage pumping stations and similar works) are allowed in the buffer with the prior approval of the Authority. A new section 12(2) allows roads, bridges, pipes, poles, towers, jack wells and sewage treatment plants "in between Full Tank Level and Maximum Water Level", provided "the original capacity of the tanks is not reduced" and inflow and outflow are not obstructed.
| Area of tank (acre.gunta, as in the Act) | Approximate area (ha) | Buffer from the revenue boundary |
|---|---|---|
| up to 0.05 | up to 0.05 | 0 m |
| above 0.05 to 0.10 | 0.05 to 0.10 | 1 m |
| above 0.10 to 1.00 | 0.10 to 0.40 | 3 m |
| above 1.00 to 10.00 | 0.40 to 4.0 | 6 m |
| above 10.00 to 25.00 | 4.0 to 10.1 | 12 m |
| above 25.00 to 100.00 | 10.1 to 40.5 | 24 m |
| above 100.00 | above 40.5 | 30 m |
The column is headed "acre/gunta" in the English text. It is read here in the revenue notation, in which 0.05 is 0 acres 5 guntas and 1 gunta is 1/40 acre (about 101 m²); the conversion to hectares is this Manual's and is to be confirmed against the authoritative Kannada text [TBC]. Drains, Bengaluru Metropolitan Region only: UDD 468 MNJ 2025(E) of 15 October 2025, made under section 13-E of the KTCP Act, 1961 and applying "irrespective of anything contained in the zonal regulations" in the RMP 2015 area, the Bengaluru–Mysuru Infrastructure Corridor and every Local Planning Area in the Region, sets buffers of 15 m, 10 m and 5 m on either side of primary, secondary and tertiary drains, measured "from the edge of drain / nala as per revenue records"; drains leading to tertiary drains get no buffer, and the lake buffer is left to the KTCDA Act. Outside the Region, drain buffers depend on each Local Planning Area's zonal regulations, which were not found. Earlier figures, all superseded: the 2003 Bengaluru bye-laws barred building sites within 9 m of the water spread of a tank at FTL (Bye-law 7.1(d)); the KTCDA Act, 2014 set 30 m from the outer boundary of every tank, which the 2018 amendment kept; the RMP 2015 zoning regulations set 30 m round lakes and 50 m, 25 m and 15 m from the centre of primary, secondary and tertiary drains; and the National Green Tribunal (Forward Foundation v. State of Karnataka, 4 May 2016) set 75 m from lakes and wetlands and 50 m, 35 m and 25 m from the edge of primary, secondary and tertiary rajakaluves as no-construction zones. On 5 March 2019 the Supreme Court (Mantri Techzone Pvt Ltd v. Forward Foundation, Civil Appeal No. 5016 of 2016) set aside direction (1) of the Tribunal's order, which contained those distances, except as against the two builders before it, whose penalties it upheld; it did not itself prescribe a buffer for other land. The draft RMP 2031 adopted the Tribunal's figures but was not approved. Coast and wetlands: along the coast the CRZ Notification, 2019 applies (a 50 m no-development zone in CRZ-III A and 200 m in CRZ-III B; 50 m or the creek width along tidal water bodies; a 50 m buffer round mangroves larger than 1,000 m²), with Karwar and Kundapur listed as Critically Vulnerable Coastal Areas; a Karnataka CZMP under the 2019 Notification appears on the national CZMP portal as approved, but the approval was not seen. Clause 7.4.7 makes 15 m the floor everywhere, and any wider statutory buffer governs under Clause 7.4.5.
Disclosure. The setbacks of this chapter are a hydraulic corridor set by this Manual, applied as the larger of that corridor and the statutory buffer in force. Zone 1 is the greatest of a 15 m maintenance strip, the floodway (the width the design flood needs) and, for a tank, the MWL contour; Zone 2 extends to the 1% AEP flood extent plus 10 m (Clauses 7.4.3 and 7.4.4). The statutory buffers set out above are much narrower, so in most places this chapter is stricter than statute, in the following respects:
- Tanks. The KTCDA buffer is 0 m to 24 m for every tank of 100 acres or less, which is most of the State's tanks, and is measured from the revenue boundary whatever the flood level. Here Zone 1 is never less than 15 m and extends to the MWL contour and the floodway.
- Foreshore. Section 12(2) of the KTCDA Act now allows roads, towers and sewage treatment plants between FTL and MWL if the tank's capacity is not reduced. This Manual treats all land below MWL as floodway (Clause 7.6.1) and allows only the crossings and drainage works of Clause 7.5.1(a) and (b) in it, each shown not to raise the 1% AEP level (Clause 7.6.2); a treatment plant or road along the tank belongs outside Zone 1.
- Drains. UDD 468 MNJ 2025(E) sets 10 m on secondary and 5 m on tertiary drains, nothing on the drains that feed them, and applies only in the Bengaluru Metropolitan Region. Here every natural channel draining 8 ha or more, recorded or not and anywhere in the State, has Zone 1 of at least 15 m (Clause 7.4.1(b)), and drains are classed by drainage area (Table 7.1), not only by the revenue-record hierarchy.
- Measurement. The statutory drain buffer runs from the drain edge as per revenue records. Here setbacks run from the larger of the revenue boundary and the surveyed FTL or top of bank (Clause 7.13.1), so a drain or tank narrowed by encroachment is measured at its recorded width.
The 15 m minimum is set by this Manual because it equals the widest drain buffer now in force (the primary drain buffer of UDD 468 MNJ 2025(E)), is above the smallest APWA default stream buffer (12 m) from which Table 7.1 is scaled, and leaves room for a maintenance track, desilting machinery and bank planting along the rajakaluves, which the CAG found unmarked and encroached (CAG, Report No. 2 of 2021). The Manual does not adopt the RMP 2015 or NGT 2016 distances as fixed widths: neither is now in force, and no fixed width follows the flood edge. Where a statute or rule is wider, it governs (Clause 7.4.5): the 30 m KTCDA buffer of tanks above 100 acres, wherever it exceeds the corridor; any wider zonal-regulation, valley-zone or Master Plan buffer; the CRZ along tidal waters; and the protection of the Ramsar sites. The reasons for the stricter values are the encroachment of lakes and rajakaluves documented by the Koliwad committee and the CAG, the September 2022 and October 2024 floods of layouts below overflowing keres, and the cascade structure of Bengaluru's valleys, in which narrowing one link raises flood levels in every tank upstream. Until a statute or rule adopts them, the statutory buffers remain the legal minimum and this chapter's values are the Manual's recommended standard. Approving authorities should state in each approval which of the two was applied.
Figure 7.1 — Waterbody setback zones: section through a tank or channel showing FTL, the 1% AEP flood level, the 15 m minimum line, Zone 1 and Zone 2. Original drawing for this Manual, adapted from Kansas City Metro APWA, Section 5600 Version 2025.01 and Policy Supplement (MARC, 2025).
7.5 Uses permitted in each zone
7.5.1 Zone 1. No building, fill, paving, retaining wall, boundary wall, compound wall, dumping of earth, debris or solid waste, storage of materials, or construction-stage stockpile shall be placed in Zone 1. Only the following are permitted, each subject to the custodian's NOC:
- (a) road, rail and utility crossings that meet Clause 7.10.3;
- (b) flood and drainage works: outfalls, inlet structures, gross pollutant traps, sluices, surplus weirs, bund strengthening and bank protection;
- (c) native vegetation, planting and habitat works;
- (d) unpaved or permeable footpaths and maintenance tracks at existing ground level; and
- (e) waterbody restoration under Clause 7.9.
7.5.2 Zone 2. No habitable building, basement, school, hospital, fuel store or hazardous-material store shall be placed in Zone 2. The following are permitted:
- (a) all uses permitted in Zone 1;
- (b) parks, playgrounds, open-air sports fields and urban agriculture;
- (c) open-sided structures (shelters, pavilions) with no walls that obstruct flow;
- (d) surface parking with permeable surfacing at existing ground level, where the 1% AEP flood depth is not more than 0.3 m;
- (e) retention, detention and water quality facilities under Chapters 4 and 8, provided they are outside the floodway and their storage is not counted twice (Clause 7.6.5); and
- (f) fill, only for (a) to (e) or for essential public infrastructure, and only with compensatory storage under Clause 7.6.4.
7.5.3 Fences. Fences in Zone 1 and Zone 2 shall be open (chain-link or railing) with no plinth wall above existing ground level, so that they do not obstruct flow or trap debris.
7.5.4 Open space reservation. Zone 2 land may be counted toward the park reservation of a layout under section 17 of the KTCP Act, 1961, or the open space required by the Building Bye-laws, where the Authority agrees. Zone 1 land shall be handed over to the custodian or kept free of private use, as the Authority decides.
Commentary. The permitted uses follow APWA 2025.01: in Zone 1, only utility and road crossings; in Zone 2, linear utilities, trails and open-sided structures; no clearing, grading, fill or paving in either zone without approval (MARC Supplement, 2025). Clause 7.5.2 adds parks and playgrounds, the uses URDPFI (2015) allows in the 10-year flood zone. The ban on walls in Clauses 7.5.1 and 7.5.3 responds to urban Karnataka practice: compound walls along channels and tanks act as dams in floods, and are often the first step toward encroachment. The 0.3 m depth limit for parking in Clause 7.5.2(d) has no direct precedent and is set by this Manual.
7.6 Floodway, flood fringe and compensatory storage
7.6.1 Floodway delineation. The floodway shall be delineated by a hydraulic model of the 1% AEP flood (with the climate factor), using the encroachment method: the conveyance of the flood fringe is removed equally from both banks until the 1% AEP water level rises by 0.1 m. Where the floodway has not been delineated, the whole 1% AEP flood extent shall be treated as floodway. For a tank, all land below MWL is floodway.
7.6.2 No fill in the floodway. No fill, building, embankment, raised road or other obstruction shall be placed below the 1% AEP flood level within the floodway, except the works permitted in Zone 1 under Clause 7.5.1(a) and (b). Those works shall be shown by hydraulic analysis to raise the 1% AEP water level by no more than 0.01 m, upstream or downstream, outside the Applicant's land.
7.6.3 Fill in the flood fringe. Fill below the 1% AEP flood level in the flood fringe is permitted only:
- (a) for uses permitted under Clause 7.5.2, or outside the setback where the Authority has notified a developed-fringe area under Clause 7.6.6; and
- (b) with compensatory storage under Clause 7.6.4.
7.6.4 Compensatory storage. Where fill is placed in the flood fringe, compensatory storage shall be provided that (Figure 7.2):
- (a) replaces at least 1.0 m³ of storage for each 1.0 m³ of fill placed below the 1% AEP flood level;
- (b) is provided at equivalent levels: the volume lost and the volume replaced shall be balanced in each elevation band of not more than 0.3 m, from the normal water level (or the 50% AEP level, where higher) up to the 1% AEP flood level;
- (c) is in the same reach of the same waterbody, hydraulically connected to it, and not further downstream than the fill;
- (d) drains freely by gravity back to the waterbody as the flood recedes, with no pumping and no permanent pool below the normal water level;
- (e) is built before, or at the same time as, the fill is placed; and
- (f) is secured by a covenant or handover so that it is never filled later.
7.6.5 No double counting. Compensatory storage shall not be counted as detention or retention storage under Chapter 4. Detention and retention storage placed within the 1% AEP flood extent shall be counted only for the volume above the 1% AEP flood level, unless a model of the joint event (Clause 2.12) shows that it is available.
7.6.6 Developed-fringe areas. The Authority may notify, by map, areas of existing built-up land within the 1% AEP flood extent but outside the floodway, where it is impractical to apply Zone 2 to redevelopment. In a notified developed-fringe area:
- (a) redevelopment may be approved without the Zone 2 restriction;
- (b) the lowest habitable floor and all openings shall be at least 0.5 m above the 1% AEP flood level (Chapter 6);
- (c) basements are not permitted;
- (d) the redevelopment shall cause no net loss of flood storage below the 1% AEP flood level (Clause 7.6.4), and stilt construction may be used for this; and
- (e) Zone 1 continues to apply in full.
Commentary. The 1:1 compensatory storage at equivalent levels is set by this Manual. A simple volume balance is not enough: storage excavated below the normal water level is full before the flood arrives and gives no flood benefit. Storage gained high up does not replace storage lost low down, because the low storage is used in every flood and the high storage only in the largest. Balancing volume within each elevation band avoids both problems. The 0.3 m band, the 0.01 m allowance for crossings, and the use of the encroachment method in Clause 7.6.1 are set by this Manual; the encroachment method is the standard way to delineate a floodway in a one-dimensional hydraulic model. The 0.1 m limit on the rise in the 1% AEP water level is tighter than the 1 ft (about 0.3 m) used by the US National Flood Insurance Program. Karnataka's coastal plains are flat, so a small rise in level spreads flooding over a wide area, and many small encroachments along the same channel add up.
Tank foreshores in Bengaluru have been lost to fill and building: the wetland between the Agara and Bellandur lakes is reported to have shrunk from 32.8 ha in 2007 to 5.95 ha in 2012 (Down To Earth, 2016, reporting the NGT proceedings), and since 2026 section 12(2) of the KTCDA Act expressly allows roads, towers and sewage treatment plants between FTL and MWL, subject only to the tank's original capacity not being reduced. Treating all land below MWL as floodway (Clause 7.6.1) means that no new building or fill is approved in a tank foreshore.
The developed-fringe mechanism of Clause 7.6.6 is set by this Manual. Large parts of the Bengaluru layouts built on valley floors and former paddy land below the keres, and the river towns of north Karnataka flooded by the Krishna, Malaprabha and Ghataprabha in 2019 already lie within the 1% AEP extent. A blanket Zone 2 ban on redevelopment there would stop the replacement of older, lower buildings with buildings raised above flood level. The mechanism follows the URDPFI (2015) approach for the 25-year flood zone (stilts, minimum plinth, no basements), applied here to the 1% AEP extent.
Figure 7.2 — Compensatory storage by elevation band: section through the flood fringe showing fill placed below the 1% AEP flood level and an equal or greater volume excavated within each band of not more than 0.3 m, from the normal water level (or 50% AEP level) up to the 1% AEP level, with the excavation draining back to the waterbody by gravity. Band-by-band calculation on Form 7-3. Original drawing for this Manual, illustrating the method of Clause 7.6.4, which is set by this Manual.
7.7 Tank cascades as design storage
Most of Karnataka's tanks are rural keres, kuntes and kattes with earthen bunds, a kodi and one or more tubus, and Clauses 7.7 and 7.8 apply to them as written. Bengaluru's keres are now mostly urban lakes: many have lost their command, receive sewage or treated wastewater, and have ungated kodis, so their storage above FTL can be counted only under Clause 7.7.1 and no flood cushion can be assumed (Clause 7.8.3). Tanks with a command of more than 2,000 ha, the reservoirs of the dams on the Sharavathi, Kali, Krishna and other rivers, and the Ramsar wetlands are not tanks for these clauses: their levels enter a design as tailwater (Chapter 5), and wetland storage is counted only at basin scale (Clause 7.12.5).
7.7.1 When tank storage may be counted. The storage of a tank or tank cascade may be counted as design storage (in a basin plan, a regional facility or a fee-in-lieu scheme under Clause 7.11) only where all of the following are met:
- (a) Surveyed levels. FTL, MWL, TBL, the surplus weir crest and length, and the sluice sill levels have been surveyed to the datum of Clause 7.3.5 within the previous 5 years.
- (b) Stage–storage curve. A stage–storage curve has been derived from a bathymetric and topographic survey of the waterspread and foreshore within the previous 5 years, or after the last desilting, whichever is later.
- (c) Operating rule. A documented operating rule has been agreed with the custodian (Clause 7.8).
- (d) Maintained structures. The surplus weir, sluices and bund are maintained under an O&M plan (Chapter 10), and the latest pre-monsoon inspection found them serviceable.
- (e) Custodian concurrence. Minor Irrigation Department, or the other custodian, concurs in writing.
Storage in a tank that fails any of (a) to (e) shall not be counted, though the tank shall still be modelled as an existing feature (Chapter 3).
7.7.2 Modelling. Tank cascades shall be modelled under Clause 3.12.5 (level-pool routing of each tank, with surplus weir and sluice ratings) and Clause 3.13 (continuous simulation). The whole cascade, from the uppermost tank whose surplus can reach the site or facility to the next river, major drain or sea outfall, shall be modelled together, including every kunte, rajakaluve and surplus course down the valley to its outlet, as shown in Figure 7.3.
7.7.3 Starting level. The starting level in every tank shall be FTL for the design-storm analysis. A lower starting level may be used only under a flood-cushion operating rule that meets Clause 7.8.
7.7.4 Design maximum level. For the 1% AEP inflow with the climate factor, routed through the cascade:
- (a) the computed maximum level shall be not higher than MWL (as defined in Clause 7.2); and
- (b) the freeboard from the computed maximum level to the lowest point of the bund (TBL) shall be not less than Minor Irrigation Department's freeboard standard for the tank.
Where (a) or (b) fails, the tank storage above FTL shall not be counted until the surplus weir capacity is increased or the bund raised under Clause 7.7.6.
7.7.5 Creditable volume. The creditable design storage of a tank is the volume between the starting level (Clause 7.7.3) and the computed maximum level of Clause 7.7.4, less any volume already committed to another facility or scheme.
7.7.6 Changes to FTL, weirs and bunds. No surplus weir crest shall be raised or lowered, no shutters or falling boards shall be added, and no bund shall be raised, cut or breached except under a design approved by the custodian that:
- (a) routes the cascade under Clause 7.7.2;
- (b) shows the effect on flood levels in the foreshore and upstream, and on flows in the surplus course and downstream; and
- (c) checks the bund under Clause 7.14.
Commentary. This Manual allows tank cascades to be used as design storage subject to three basic conditions (surveyed FTL, a documented operating rule and maintained surplus weirs). Clause 7.7.1 adds the stage–storage survey and the custodian's concurrence, because the storage a tank actually offers depends on its silt level and on who controls the sluices. The 5-year survey interval is set by this Manual.
The FTL starting level follows Clause 3.12.5. In Bengaluru the keres are full when the large storms come. After the rain of late August and early September 2022, 126 lakes were reported to be overflowing, 42 of them in Mahadevapura zone, and the layouts on the valley floor below them, among them Rainbow Drive, Yemalur and Sunny Brooks, were flooded (The News Minute, 10 September 2022, reporting BBMP figures; Reuters, September 2022). Yelahanka lake, fed by the Allalasandra–Puttenahalli–Amani chain, overflowed into Kendriya Vihar in November 2021, and again on 6, 16 and 21–22 October 2024, the last time to a depth reported as up to 6 ft, while Doddabommasandra lake overflowed "after more than 17 years" (The News Minute, 23 November 2021 and 22 October 2024). Assuming spare tank capacity that is not there is the error Clause 7.7.3 prevents. A tank cascade passes floods from one tank to the next, so a design that counts storage in one tank and ignores the surplus arriving from the tank above it will overstate the benefit. That is why Clause 7.7.2 requires the whole cascade to be modelled.
Figure 7.3 — Tank (kere) cascade in a Bengaluru valley, in plan: an upper kere and a kunte with their bunds (ēri or katte), surplus weirs (kodi) and sluices (tubu), joined by rajakaluves with the drain buffers of UDD 468 MNJ 2025(E) (15 m primary, 10 m secondary, from the drain edge); an urban inflow through treatment, with sewage intercepted and kept out of the tank; a large kere with its foreshore between FTL and MWL, its KTCDA buffer graded by tank size (Karnataka Act No. 19 of 2026), and the setback of Clause 7.4; the layout on the valley floor below it; and the surplus course to the next kere and the valley outlet. Original drawing for this Manual; concept from the tank series of Bengaluru's Koramangala–Challaghatta, Hebbal and Vrishabhavathi valleys and the buffers of the KTCDA Act and UDD 468 MNJ 2025(E), with setback zones adapted from Kansas City Metro APWA, Section 5600 Version 2025.01 (MARC, 2025).
7.8 Operating rules and pre-monsoon flood cushion
7.8.1 Operating rule content. Every tank whose storage is counted under Clause 7.7 shall have a written operating rule, agreed by the custodian and kept with the O&M plan (Chapter 10). It shall state:
- (a) the levels and dates for filling, holding and drawdown through the year;
- (b) the sluice and regulator settings at each level;
- (c) who operates the sluices and regulators, and who may order a release;
- (d) the maximum release rate, set so that the release, added to the flow from the downstream catchment, does not cause flooding of buildings downstream;
- (e) the forecast and warning triggers (IMD district warnings, KSDMA alerts, and city forecast systems where available) and the actions taken at each trigger;
- (f) communication with downstream ULBs and residents before any release; and
- (g) the records to be kept: daily levels in the monsoon, releases, and gate settings.
7.8.2 Flood cushion. A tank may be operated with a flood cushion (a level below FTL during part of the monsoon), and the cushion counted under Clause 7.7.3, only where:
- (a) the tank has a gated sluice, regulator or other controllable outlet able to draw the tank down to the cushion level in the time stated in the rule;
- (b) the operating rule fixes the cushion level and the dates it applies;
- (c) continuous simulation (Clause 3.13) shows that the cushion is available at the start of a design storm in at least 90% of monsoon seasons in the record, allowing for the rain that usually comes before the peak storm;
- (d) the custodian accepts any loss of irrigation or water-supply yield, and any agreed compensation is recorded; and
- (e) the release needed to create or restore the cushion meets Clause 7.8.1(d).
7.8.3 No storage credit without control. Where a tank has no controllable outlet, no flood cushion shall be assumed, whatever the past practice.
7.8.4 Coordination. For tanks under Minor Irrigation Department control, the operating rule shall be Minor Irrigation Department's rule. This Manual does not authorise any other body to operate a Minor Irrigation Department tank.
Commentary. No Karnataka operating rule for a kere or kunte that keeps a flood cushion was found. The practice runs the other way: most Bengaluru keres have ungated kodis and are kept full, and the World Bank-supported Karnataka Water Security and Resilience Program funds the filling of 40 Minor Irrigation lakes with treated wastewater (World Bank, Technical Assessment, 2025), which leaves no spare volume below FTL. The nearest precedent for designed flood storage is the 2010 master plan for Bengaluru's drains, which proposed detention ponds on institutional, defence and park land and retention basins at drain confluences (STUP Consultants for BBMP, 2010); no evidence was found that they were built. KSNDMC's Urban Flood Model for Bengaluru, with its telemetric rain gauges and water-level sensors on the drains, could supply the forecast triggers of Clause 7.8.1(e). Clause 7.8.2 turns the principle into a rule that can be checked, with a reliability test, because a cushion that is usually refilled by the June–August rain gives no protection in a September or October storm. The 90% reliability in Clause 7.8.2(c) has no direct precedent and is set by this Manual.
Irrigation, recharge and drinking water remain the primary purposes of most rural tanks, and many urban keres now serve recharge and amenity. A flood cushion has a cost in yield, which is why Clause 7.8.2(d) requires the custodian to accept it.
7.9 Restoration, desilting and deepening
7.9.1 Pre-works survey. Before any desilting or restoration, the proponent shall:
- (a) survey the waterspread, foreshore, bund, weirs and sluices (Clause 7.7.1(a) and (b));
- (b) find the original bed level by test pits or augering on a grid, and from historical records where available; and
- (c) where the tank receives urban runoff or sewage, test the silt for heavy metals and other contaminants before disposal is planned.
7.9.2 Desilting limit. Desilting shall remove accumulated sediment down to the original bed level. It shall not deepen the tank below the original bed, except under Clause 7.9.3.
7.9.3 Deepening. Deepening below the original bed is permitted only where a hydrogeological report shows that:
- (a) it will not cut through a clay or silt layer that holds water in the tank or protects an aquifer from polluted water;
- (b) in coastal areas, it will not draw saline water into the tank or the aquifer; and
- (c) the extra storage will be refilled and used, and will not stand stagnant below the sluice sill.
Storage created below the lowest sluice sill shall not be counted as flood storage.
7.9.4 Safe edges. Where the public has access to the waterbody edge:
- (a) side slopes shall be no steeper than 1V:4H from 0.5 m above FTL down to 1.2 m below FTL, or a level safety bench at least 3 m wide shall be provided between 0.3 m and 0.5 m below FTL; and
- (b) no isolated deep pit or vertical cut shall be left in the bed.
7.9.5 Storage not to be reduced. Restoration shall not reduce the storage below MWL. Islands, walkways, bund widening into the waterspread, ring roads, parking, buildings and "lake-front" platforms within the waterspread or foreshore shall be counted as lost storage and shall be offset under Clause 7.6.4.
7.9.6 Silt disposal. Desilted material shall not be placed within the setback, on the bund (except for approved bund strengthening), or on any flood path. Silt found to be contaminated shall be disposed of as the Karnataka State Pollution Control Board directs.
7.9.7 Inlet treatment. Every restoration of a tank that receives urban runoff shall include sediment and gross pollutant control at each inlet: a sediment forebay, a constructed wetland inlet zone, or a gross pollutant trap (Chapter 8), so that the restored storage does not silt up again.
7.9.8 Timing. Desilting shall be completed, and the waterbody made safe, by 30 April each year (Chapter 10).
Commentary. The CAG found that annual maintenance contracts covered only 377 of the 842 km of Bengaluru's primary and secondary drains, and that desilting was done during the monsoon rather than before it (CAG, Report No. 2 of 2021, as summarised by Citizen Matters, 2021); the State told the CAG in January 2019 that a maintenance manual would be prepared, and there had been no action by August 2020. No Karnataka standard for desilting tanks was found. The 30 April deadline matches the pre-monsoon inspection date of Chapter 10. The limits on deepening are set by this Manual. Deepening tanks to "increase capacity" is common, but it can breach the silt and clay layer that holds water in the tank, it can let polluted urban water reach the aquifer, it can draw salt water toward the coast, and it creates storage below the sluice sill that never empties and gives no flood benefit. Deep pits with steep sides are also a drowning hazard. The slope and bench values in Clause 7.9.4 are adapted from common pond-safety practice; they have no Karnataka precedent.
7.10 Supply channels, surplus courses, inlets and outlets
7.10.1 Part of the major system. Supply channels and surplus courses are part of the major drainage system (Chapter 6). They shall be protected as waterbodies, with Zone 1 and Zone 2 setbacks under Clause 7.4.
7.10.2 No closure or covering. No supply channel or surplus course shall be closed, filled, diverted, covered, culverted along its length, or converted into a road or a closed drain, except under a design approved by the custodian that keeps or increases its 1% AEP capacity and its access for maintenance.
7.10.3 Crossings. Every road, rail, utility or access crossing of a waterbody, supply channel or surplus course shall:
- (a) pass the 1% AEP flow (with the climate factor), or the surplus of the upstream tank at its MWL, whichever is greater, with the freeboard required by Chapter 9;
- (b) not reduce the waterway width at the crossing below the full channel width as recorded in Revenue records or as surveyed, whichever is greater;
- (c) keep the channel bed level and grade; and
- (d) not raise the 1% AEP water level by more than the limit in Clause 7.6.2.
7.10.4 Capacity. The design capacity of a surplus course shall be the greater of the surplus weir discharge at MWL and the 1% AEP flow from its own catchment, combined as the cascade model (Clause 7.7.2) shows.
7.10.5 Protection at structures. Outlets of surplus weirs and sluices, and drain outfalls into waterbodies, shall have energy dissipation and scour protection designed under Chapter 9, so that the flow leaving them does not erode the bund, the bank or the channel bed.
7.10.6 Drain outfalls into waterbodies. A storm drain outfall into a tank, channel or wetland shall:
- (a) have its invert at or above the normal water level of the receiving waterbody, unless the drain is designed for submerged outfall under Chapter 5;
- (b) be located and aligned so that it does not cut through or weaken a tank bund;
- (c) have a gross pollutant trap and first-flush treatment (Chapter 8); and
- (d) not carry sewage or dry-weather flow (Chapter 8).
Commentary. This Manual protects supply channels and surplus courses as part of the major system. In urban areas they are often the first to be lost. Surplus courses are narrowed by culverts and compound walls, and supply channels are covered and turned into roads, which cuts the tank off from its source or leaves its surplus with nowhere to go. Bengaluru's corporation told the National Green Tribunal that the city's storm water drains "were not planned for flood water management but are erstwhile irrigation channels", whose cross-sections are not in line with the discharge they now carry, and that flow velocities had risen 1.8 to 8.4 times (BBMP compliance report in OA 125/2017, 26 February 2021). The Tribunal had directed "No further channelization and concretization of Rajakaluves" (order of 18 December 2019, as quoted in that report); the corporation replied that 389 of 842 km were already walled and about 325 km more needed walls. The CAG found sewer lines crossing about 28 km of drains at 342 points in the Vrishabhavathi valley, and no boundary marks on any drain it checked (CAG, Report No. 2 of 2021). In November 2021 residents blamed debris in a rajakaluve as well as the overflow of Yelahanka lake for the flooding of Kendriya Vihar (The News Minute, 23 November 2021). Clause 7.10.3(b) prevents a crossing from narrowing a channel to its current, encroached width.
7.11 Fee-in-lieu and regional tank storage
7.11.1 Where a basin plan has been notified, and the Authority has adopted alternative S-5 of the Policy Supplement (Clause 1.7), a development may pay a fee in lieu of on-site detention under Chapter 4. The fee shall be applied to restoring or creating storage in a tank, pond or regional facility in the same basin.
7.11.2 Tank storage funded by fee-in-lieu shall:
- (a) meet Clause 7.7.1 in full before it is counted;
- (b) be downstream of the contributing development and upstream of the flood-prone area it is meant to protect;
- (c) be created, or under construction, before the development it serves is occupied, or within a period the basin plan fixes; and
- (d) be recorded in the register of Clause 10.17 with the developments that funded it, so that the same volume is not sold twice.
7.11.3 Fee-in-lieu does not replace:
- (a) the retention requirement of Chapter 4, which is always met on site; or
- (b) the water quality requirement of Chapter 8, which is met on site or in a regional facility treating the same runoff before it reaches the tank.
Commentary. Chapter 4 provides for fee-in-lieu toward restored kere or tank storage in master-planned basins. Malaysia's 2008 DID checklist allowed on-site detention only for small sites and required community ponds for larger areas (DID, 2008). Karnataka already has some 17,015 tanks (1st Census of Water Bodies) that can serve the same purpose if their storage is restored and controlled; in Bengaluru the World Bank counts 204 cascading lakes, of which "the remaining 183 lakes hold great potential" (World Bank, Technical Assessment, 2025). UDD 468 MNJ 2025(E) and the RMP 2015 zoning regulations allow a lake buffer, or valley land within a layout, to be counted toward park reservation; a layout-level pond there could be designed as storage under this Manual, outside Zone 1. Clause 7.11.2(b) matters because a tank downstream of the flood-prone area protects nothing. Clause 7.11.3 keeps retention on site: it is the volume-control layer of this Manual, and a regional tank cannot recharge the aquifer under the developed site.
7.12 Wetlands, marshes and estuaries
7.12.1 Scope. This clause applies to marshes, swamps, backwaters, estuaries, and tidal creeks and lagoons, including:
- (a) wetlands notified under the Wetlands (Conservation and Management) Rules, 2017 or listed by the Karnataka State Wetland Authority;
- (b) the Ramsar sites: Ranganathittu, the Aghanashini estuary, Magadi Kere and Ankasamudra;
- (c) the Bellandur–Agara–Varthur lakes and the marshes at the inlets of other keres, the estuaries of the Netravati–Gurupura, Swarna–Sita, Sharavathi, Aghanashini and Kali and the smaller river mouths (alive) of the coast, and their mangroves; and
- (d) any other marsh, estuary or backwater that the Authority notifies.
7.12.2 No drainage of wetlands. No drain, channel, cut or pump shall be designed to drain a wetland, to lower its normal water level, or to reduce the period for which it is wet, except under a plan approved by the wetland authority.
7.12.3 Inflows. Every drain discharging into a wetland in Clause 7.12.1 shall:
- (a) meet Clause 7.10.6;
- (b) pass through water quality treatment for the WQv of its catchment (Chapter 8) before entering the wetland; and
- (c) where practicable, spread its flow across a vegetated margin rather than discharge at one point.
7.12.4 Hydraulic connectivity. Roads, embankments and utility corridors across or along a wetland shall have openings that:
- (a) pass the 1% AEP flow without raising the 1% AEP water level by more than the limit in Clause 7.6.2; and
- (b) keep the wetland's normal water exchange, including tidal exchange in estuaries, with openings spread along the crossing so that no part of the wetland is cut off.
7.12.5 Storage counted at basin scale only. Wetland storage shall be included in basin and regional models. It shall not be counted as detention for any individual development.
7.12.6 Tidal wetlands and estuaries. For estuaries and tidal wetlands:
- (a) tailwater shall be taken from Chapter 5 (Clause 2.12 joint cases);
- (b) works shall also comply with the Coastal Regulation Zone Notification in force; and
- (c) mouth-opening works, training walls and dredging are outside the scope of this Manual and need their own studies.
7.12.7 No dumping. No solid waste, construction debris or dredged material shall be placed in a wetland or its setback.
Commentary. Karnataka has four Ramsar sites, and two of them are man-made tanks: Ranganathittu on the Kaveri (518 ha, 2022), the Aghanashini estuary in Kumta taluk (4,801 ha, 2023), Magadi Kere in Gadag district (54 ha, 2023), "a human-made wetland that was primarily constructed to store monsoon rainwater for irrigation", and Ankasamudra in Vijayanagara district (99 ha, 2023), built for storing monsoon run-off (Ramsar annotated list). A kere is therefore a wetland as well as an irrigation work. In Bengaluru, Bellandur lake, with a catchment of about 148 km², receives three chains of lakes and drains to Varthur; it frothed repeatedly between 2015 and 2019 and caught fire in 2015, 2017, 2018 and 2021 (secondary sources). In OA 125/2017 the National Green Tribunal imposed environmental compensation of ₹50 crore on the State and ₹25 crore on the corporation and ordered ₹500 crore placed in escrow for an action plan (6 December 2018, as reported by The News Minute). Whether any Karnataka wetland has been notified under the Wetlands (Conservation and Management) Rules, 2017 was not confirmed. Clause 7.12.2 targets a specific risk: drains built to relieve flooding next to a marsh can drain the marsh itself, and once it is dry it is encroached. Most of Bengaluru's lakes receive sewage through the storm drains: the CAG estimated about 780 MLD of sewage mixing with stormwater in the city's drains (CAG, Report No. 2 of 2021), Varthur lake receives the sewage that passes through Bellandur upstream, and the CPCB is reported to have found 172 of 187 lakes of unacceptable quality in 2025 (SANDRP, 2025, compiling press reports). On the coast, the Aghanashini estuary supports intertidal mudflats, salt-tolerant rice and more than 6,000 households (Ramsar record). The rules on outfalls and treatment in Clause 7.12.3 respond to both.
7.13 Encroachment interfaces
7.13.1 Boundary. For design under this Manual, the boundary of a waterbody is the larger of its Revenue record boundary and its surveyed FTL (or top of bank), as in Clause 7.3.3. Setbacks are measured from that boundary.
7.13.2 No reliance on encroached land. No design shall:
- (a) count, as storage or conveyance, land within a waterbody boundary that is occupied by encroachment, unless its removal is ordered and funded; or
- (b) treat the encroached width of a channel as its design width.
7.13.3 Public works in encroached reaches. Where a public drainage work passes through an encroached reach:
- (a) it shall be designed for the full waterbody width (Clause 7.13.1);
- (b) where the full width cannot be cleared before the work is built, the design report shall state the interim capacity and the flood risk until it is cleared; and
- (c) the work shall be built so that the full width can be restored later without rebuilding it.
7.13.4 Boundary marking. Every development adjoining a waterbody shall, before the completion certificate:
- (a) mark the outer edge of Zone 1 on the ground with permanent survey markers at intervals of not more than 30 m and at every change of direction; and
- (b) show the setback zones on the approved layout plan and in the sale documents of every plot that includes setback land.
7.13.5 Retaining walls. No retaining wall, bund or embankment shall be built along the edge of a waterbody, within Zone 1, to protect or reclaim land, except to protect existing public infrastructure under the custodian's approval.
Commentary. The Koliwad committee of the Karnataka Legislature found about 11,000 acres of lake land encroached across 1,545 lakes in Bengaluru Urban and Rural districts, about a third of it by the Bangalore Development Authority and two-thirds by private builders (interim findings, as reported by Business Standard, 8 January 2016; the final report was not seen). The CAG found 2,626 encroachments on Bengaluru's storm water drains, of which 714 had not been acted on, and doubted "the veracity of the claim of having removed the encroachments" (CAG, Report No. 2 of 2021); the corporation reported 2,666 identified and 2,052 removed to the High Court in October 2022. The High Court of Karnataka, in Citizens' Action Group v. State of Karnataka (WP 38401/2014), directed the immediate removal of all encroachments on storm water drains in September 2022 and a joint action plan by the city, UDD, Revenue Department, BWSSB and KSPCB in August 2023 (as reported by LiveLaw; the certified orders were not seen). Drain land is Revenue land, and eviction runs through a survey by the Assistant Director of Land Records, an order of the Tahsildar under section 104 of the Karnataka Land Revenue Act, 1964, and removal by the zonal Executive Engineer (World Bank, Environmental and Social Systems Assessment, 2025). The Karnataka Municipal Corporations Act, 1976 already required boundary marks on drains (section 58) and barred structures on them (section 234), as cited by the CAG. This Manual cannot evict anyone. It can stop designs from treating encroachment as permanent (Clause 7.13.2), make public works restorable to full width (Clause 7.13.3), and make the setback visible on the ground and in property documents so that new buyers know it is there (Clause 7.13.4). The 30 m marker interval is set by this Manual.
7.14 Safety of tank bunds and embankments
7.14.1 Dam Safety Act screening. For every tank, and every embankment built or altered under this Manual, the designer shall determine whether it is a "specified dam" under the Dam Safety Act, 2021. Under the Act, a specified dam is a dam:
- (a) more than 15 m high, measured from the lowest point of the general foundation area to the top of the dam; or
- (b) between 10 m and 15 m high, where the crest length is not less than 500 m, or the reservoir capacity is not less than one million m³, or the maximum flood discharge dealt with by the dam is not less than 2,000 m³/s, or the dam has specially difficult foundation problems, or the dam is of unusual design.
Where it is a specified dam, the Act and the requirements of the State Dam Safety Organisation govern, in addition to this Manual.
7.14.2 Hazard class. Every tank bund and detention embankment that is not a specified dam shall be given a hazard class:
- High hazard: a breach could flood a habitable building, a school, a hospital, an arterial road or critical infrastructure.
- Low hazard: any other case.
7.14.3 High-hazard embankments. For high-hazard tank bunds and embankments:
- (a) the surplus weir or spillway shall pass the 1% AEP inflow at MWL with the freeboard of Clause 7.7.4(b), and shall be checked for the 0.2% AEP (500-yr) inflow without overtopping the bund (as for detention basins in Chapter 4);
- (b) a breach analysis shall map the area flooded by a breach at MWL;
- (c) an emergency action plan shall be prepared, with the warning and evacuation arrangements for the breach area; and
- (d) the design shall be certified and independently checked under Clause 10.6.
7.14.4 Inspection. Every tank whose storage is counted under Clause 7.7, and every high-hazard embankment, shall be inspected before the monsoon (by 30 April) and after every heavy-rainfall event (Chapter 10) for seepage, slips, cracks, animal burrows, trees on the bund, and blockage of the weir and sluices.
7.14.5 No unauthorised cutting. No person shall cut, lower or breach a tank bund or surplus weir during a flood except under the custodian's emergency procedure.
Commentary. The definition of a specified dam is quoted from the Dam Safety Act, 2021 (Act 41 of 2021). The Act defines a "dam" as an artificial barrier constructed across rivers or tributaries to impound or divert water. It excludes flood embankments, dikes and guide bunds. No register of the heights of Karnataka's tank bunds was found. Most keres, kuntes and kattes have low earthen bunds and are unlikely to be specified dams, but large old tanks, and tanks with a command of more than 2,000 ha (which are outside the KTCDA Act and held by the WRD), should be screened under Clause 7.14.1. Whether a tank bund that is not across a river or tributary is a "dam" under the Act is not clear from its text. In November 2019 the bund of Hulimavu lake in south Bengaluru breached and about 800 houses below it were flooded (The Hindu, 24 November 2019, as cited in secondary sources). In October 2024 a 50 ft compound wall beside Yelahanka lake collapsed and let the lake into Kendriya Vihar (The News Minute, 22 October 2024). A breach or wall failure below a full kere floods the layout on the valley floor within minutes, which is why Clause 7.14.3 asks for breach mapping of high-hazard tanks. The hazard classes, the breach analysis and the emergency action plan for high-hazard tanks are set by this Manual. They extend the Chapter 4 requirement for detention basins (1% AEP spillway with outlet blocked, 0.2% AEP for high-hazard basins) to tanks that are counted as design storage.
7.15 Submittal requirements
Every drainage report for a development or work under Clause 7.1.2 shall include:
- the Waterbody Sheet (Form 7-1) under Clause 7.3.2, with the setback zones and their basis (mapped extent, hydraulic study or fixed width);
- the hydraulic study of the 1% AEP extent and floodway, where Clause 7.3.4 requires it;
- the Compensatory Storage Calculation (Form 7-3), by elevation band, where fill is proposed in the flood fringe;
- for any tank storage counted: the Tank Storage Credit Sheet (Form 7-2), with the survey, stage–storage curve, operating rule, cascade model results and custodian concurrence of Clause 7.7.1;
- for any crossing, outfall or work in Zone 1: the custodian's NOC and the hydraulic analysis of Clause 7.6.2 or 7.10.3;
- for restoration or desilting: the pre-works survey, silt tests and hydrogeological report of Clause 7.9; and
- for any embankment: the Dam Safety Act screening and hazard class of Clause 7.14.
7.16 Review and update
7.16.1 This chapter shall be reviewed with the rest of the Manual (Chapter 1). The fixed-width table of Clause 7.4.6 shall also be reviewed within 2 years of the Authority adopting 1% AEP flood maps for its area.
7.16.2 Where the Authority adopts new 1% AEP flood maps, they apply to new submittals 6 months after adoption, unless the Authority notifies otherwise.
References (chapter)
- Government of Karnataka. Karnataka Tank Conservation and Development Authority Act, 2014 (Karnataka Act No. 32 of 2014), with the amendments of Karnataka Act No. 15 of 2018 (annotated compilation, ss. 2(1)(g), 12 and 23). https://data.opencity.in/dataset/474383d7-8430-4580-8d1d-709d7c7acbd4/resource/b99c9b35-db0b-4758-bf0b-eeb6fdd33f9f/download/ktcda-act-2014-with-amendment-in-2018-with-comments-v6.pdf
- Government of Karnataka (2026). Karnataka Tank Conservation and Development Authority (Amendment) Act, 2025 (Karnataka Act No. 19 of 2026), Karnataka Gazette Extraordinary Part IVA No. 160, 18 February 2026 (s. 12(2) and (3)). https://data.opencity.in/dataset/2a2c0701-853e-4db3-b1d4-06ee8674c628/resource/ffff8ed9-228d-42a2-a596-3b4c06a8d726/download/lake-tank-buffer.pdf
- Urban Development Department, Government of Karnataka (2025). Notification No. UDD 468 MNJ 2025(E), 15 October 2025, under s. 13-E of the Karnataka Town and Country Planning Act, 1961 (buffers for lakes and drains in the Bengaluru Metropolitan Region), Gazette Part IVA No. 656. https://data.opencity.in/dataset/884f1299-8b97-4581-9d01-efb7e994bf4d/resource/df676aa0-4b2a-4566-b94d-e920f3e421b3/download/c7a5323a-0c90-49cc-ac30-5e9e9119ed28.pdf ; Notification No. UDD 235 MNJ 2025(E), 5 January 2026 (setbacks and basements). https://data.opencity.in/dataset/31a482fe-4ffd-4929-a61d-2fdcca90be91/resource/36f1c5e6-5f5d-4356-bfba-00c5fe1020e2/download/udd-235-mnj-2025e-05.01.2026.pdf
- Bangalore Development Authority (2007). Revised Master Plan 2015, Vol. III: Zoning of Land Use and Regulations (G.O. No. UDD 540 BEM AA SE 2004, 22-06-2007), Definition 18 and Regulation 4.12.2. https://data.opencity.in/dataset/3ba2ed19-5d9a-4c1a-999c-f48f7574684d/resource/dc23b4ae-e020-4499-b18d-8e4ed2f86a24/download/35d71c70-13b7-457d-a123-5a84987f67a6.pdf ; draft RMP 2031, Zoning Regulations, Regulation 6.5.3 (not approved). https://data.opencity.in/dataset/91a1d04b-3ac2-4096-9cdd-a6062b1cb8e1/resource/42b74359-dc93-4433-92b8-1af1242568e3/download/6b3f7724-00ec-4ea5-83b0-592ff0958f39.pdf
- Bangalore Mahanagara Palike (2004). Building Bye-Laws, 2003, Bye-law 7.1. https://data.opencity.in/dataset/d7ebf3ea-faea-4d6b-ad20-7b2ff328ad3b/resource/5674a632-ffd5-4636-9804-89c52f0c631a/download/a84859f3-21d4-4d77-9100-b8004bb94899.pdf
- Supreme Court of India (5 March 2019). Mantri Techzone Pvt Ltd v. Forward Foundation, Civil Appeal No. 5016 of 2016 (as summarised; certified judgment not seen). https://www.legalauthority.in/judgement/mantri-technoze-pvt-ltd-vs-forward-foundation-40540 ; LiveLaw (6 March 2019). https://www.livelaw.in/top-stories/sc-sets-aside-ngt-order-enlarging-buffer-zones-around-bengaluru-water-bodies-143346
- Comptroller and Auditor General of India (2021). Performance Audit of Management of Storm Water in Bengaluru Urban Area, Report No. 2 of 2021, Government of Karnataka. https://data.opencity.in/dataset/cbf55fdb-d811-41a3-8c6d-99cf3210e2a4/resource/3f5c9855-9e2c-4406-8578-ca8d7de214f0/download/b19f06de-5186-4bd7-a4aa-4977a32f934f.pdf ; Citizen Matters (4 December 2021), summary of the maintenance findings (secondary). https://citizenmatters.in/cag-report-storm-water-drain-design-maintenance-issues-70468
- Ministry of Jal Shakti (2023). 1st Census of Water Bodies, Vol. 2 (State-wise), Karnataka chapter. https://mowr.nic.in/irrigationcensus/sites/default/files/State20230825411930292.pdf ; Rajya Sabha, unstarred question of 16 Dec 2024 (encroached water bodies). https://rsdebate.nic.in/bitstream/123456789/752660/1/PQ_266_16122024_U2312_p400_p403.pdf
- Ministry of Environment, Forest and Climate Change (2019). Coastal Regulation Zone Notification, G.S.R. 37(E), 18 January 2019 (para 3.1, CVCAs; NDZ; mangrove buffer). https://czmp.ncscm.res.in/2019-notification.pdf ; NCSCM, Karnataka CZMP 2019 viewer. https://gisportal.ncscm.res.in/portal/apps/webappviewer/index.html?id=56f54742e3b64822bfe6db78f3537ea2
- World Bank (2025). Karnataka Water Security and Resilience Program (P506272): Technical Assessment; Environmental and Social Systems Assessment. https://data.opencity.in/dataset/d74ff824-fa87-443f-98f3-ee498769ac4c/resource/d7891642-ed57-4794-924f-21164d52a4fd/download/56d19d7a-bd0c-405d-abe5-8dfd9322e21d.pdf ; https://data.opencity.in/dataset/d74ff824-fa87-443f-98f3-ee498769ac4c/resource/61f7c13c-21e3-4c2d-88d3-168488f6a219/download/5e92a15b-1820-4d33-b2ea-137e81aaf6f5.pdf
- STUP Consultants for BBMP (2010). Master Plan for Remodeling of Storm Water Drains in Eight Zones of BBMP, Vol. 1, Main Report. https://data.opencity.in/dataset/1d0768dd-c964-48fc-bee0-087ec40ce926/resource/1665169a-9630-4184-a905-1b7726dae9cf/download/4d59fb2c-7658-4e82-af2c-85a969a118d6.pdf
- Government of India. The Dam Safety Act, 2021 (Act 41 of 2021). https://www.casemine.com/act/in/626f9167714d58ef62b50d09 ; CWC, Specified Dam. https://rrssd.cwc.gov.in/specified-dam
- MoHUA (2015). Urban and Regional Development Plans Formulation and Implementation (URDPFI) Guidelines, Vol I. https://web.archive.org/web/2022/https://mohua.gov.in/upload/uploadfiles/files/URDPFI%20Guidelines%20Vol%20I(2).pdf
- Mid-America Regional Council (2025). APWA Stormwater Standards Supplement (Section 5600, Version 2025.01). https://www.marc.org/document/apwa-stormwater-standards-supplement
- Kansas City Metro Chapter APWA (2006). Section 5600 Storm Drainage Systems and Facilities (§5605.3 stream buffers). https://www.kcwater.us/wp-content/uploads/2020/08/Design-Criteria-%E2%80%93-Section-5600-%E2%80%93-Storm-Drainage-Systems-and-Facilities.pdf
- Department of Irrigation and Drainage Malaysia (2008). Submission Checklist for Stormwater Management. https://www.water.gov.my/jps/resources/auto%20download%20images/5844dfbba8fc1.pdf
- Ramsar Convention. Annotated summary of Ramsar sites, India (Ranganathittu 2473; Aghanashini Estuary 2534; Ankasamudra 2535; Magadi Kere 2536). https://rsis.ramsar.org/sites/default/files/rsiswp_search/exports/Ramsar-Sites-annotated-summary-India.pdf
- National Green Tribunal. BBMP compliance report and affidavit in OA 125/2017 (Court on its own motion v. State of Karnataka, Bellandur), 2020–21. https://www.greentribunal.gov.in/sites/default/files/news_updates/AFFIDAVIT%20BY%20BBMP%20IN%20OA%20NO.%20125%20of%202017%20(COURT%20ON%20ITS%20OWN%20MOTION%20VS%20STATE%20OF%20KARNATAKA)_0.pdf
- LiveLaw (2022, 2023). Reports of the High Court of Karnataka orders in Citizens' Action Group v. State of Karnataka, WP 38401/2014 (secondary; certified orders not seen). https://www.livelaw.in/amp/news-updates/karnataka-high-court-storm-water-drains-encroachments-lakes-pollution-209118 ; https://www.livelaw.in/amp/high-court/karnataka-high-court/karnataka-high-court-bbmp-remove-encroachments-storm-water-drains-lakes-bengaluru-234108
- Business Standard (8 January 2016). Karnataka panel confirms 11,000 acres lake land encroached in Bengaluru (Koliwad committee, interim findings; secondary). https://www.business-standard.com/article/current-affairs/karnataka-panel-confirms-11-000-acres-lake-land-encroached-in-bengaluru-116010800849_1.html
- Down To Earth (2016). NGT halts construction on wetland between Bengaluru lakes (secondary). https://www.downtoearth.org.in/news/water/ngt-halts-construction-on-wetland-between-bengaluru-lakes-53909
- Reports of the Bengaluru lake floods (secondary): The News Minute (23 November 2021), https://www.thenewsminute.com/amp/story/karnataka/ground-report-over-3000-residents-kendriya-vihar-bengaluru-remain-stranded-157928 ; (10 September 2022), https://www.thenewsminute.com/karnataka/126-lakes-overflowed-bengaluru-following-heavy-rains-september-says-bbmp-167743 ; (22 October 2024), https://www.thenewsminute.com/amp/story/karnataka/bengalurus-kendriya-vihar-apartments-in-yelahanka-flood-for-the-third-time-in-a-month ; (6 December 2018, NGT Bellandur order), https://www.thenewsminute.com/amp/story/karnataka/karnataka-govt-bengaluru-civic-body-fined-failing-clean-bellandur-lake-92870 ; Reuters via Inquirer (September 2022), https://newsinfo.inquirer.net/1659860/water-recedes-in-parts-of-indias-bengaluru-residents-venture-out/amp ; The News Minute (24 May 2025, flood-prone spots), https://www.thenewsminute.com/videos/why-bengaluru-floods-every-year-lme-74 ; Citizen Matters (25 July 2025, flood-prone locations), https://citizenmatters.in/?p=87431
- SANDRP (2025). 2024: approach to restore Bengaluru lakes (secondary, compiling press reports). https://sandrp.in/2025/03/11/2024-approach-to-restore-bengaluru-lakes/
- Wikipedia. Lakes in Bengaluru; Bellandur Lake (secondary, for lake counts and the Hulimavu breach of 2019). https://en.wikipedia.org/wiki/Lakes_in_Bengaluru ; https://en.wikipedia.org/wiki/Bellandur_Lake
- Kittel, F. (1894). A Kannada-English Dictionary. Digital Dictionaries of South Asia, University of Chicago (query interface). https://dsal.uchicago.edu/cgi-bin/app/kittel_query.py?qs=%E0%B2%95%E0%B3%8B%E0%B2%A1%E0%B2%BF&searchhws=yes&matchtype=exact ; Krishna, V. Alar Kannada–English dictionary. https://alar.ink/dictionary/kannada/english/%E0%B2%95%E0%B3%8B%E0%B2%A1%E0%B2%BF
- Government of India. Wetlands (Conservation and Management) Rules, 2017; Coastal Regulation Zone Notification, 2019.
Annexes and forms
| Annex / Form | Content |
|---|---|
| 7A | Statewide waterbody GIS layer and inventory fields |
| 7B | Fixed-width setback table (alternative S-3, with Annex 1C) |
| 7C | Template tank operating rule, with flood cushion |
| 7D | Desilting and restoration specification |
| 7E | Glossary of Kannada waterbody terms and regional variants |
| Form 7-1 | Waterbody Sheet |
| Form 7-2 | Tank Storage Credit Sheet |
| Form 7-3 | Compensatory Storage Calculation (by elevation band) |
Commentary. Karnataka is a tank state. The 1st Census of Water Bodies (reference year 2017-18) counted 27,013 water bodies in the State, of which 17,015 are tanks; only 789 were recorded as urban, and all 948 reported as encroached were rural (Ministry of Jal Shakti, 2023). Those figures understate the towns: a committee of the State Legislature found about 11,000 acres of lake land encroached across 1,545 lakes in Bengaluru Urban and Rural districts alone (Koliwad committee, interim findings, as reported by Business Standard, 8 January 2016). Bengaluru drains through three valleys, Koramangala–Challaghatta, Hebbal and Vrishabhavathi, each a chain of keres joined by rajakaluves, and the CAG records, citing IISc, that the 1,452 water bodies of the early 1800s had fallen to 194 by 2016 (CAG, Report No. 2 of 2021). The KTCDA Act, 2014 defines a tank to include its rajakaluve, feeder inlets, bunds, weirs, sluices and outlets, so the State's own law already treats the kere and its channels as one system. Loss of that system recurs in the State's floods: 126 lakes overflowed in Bengaluru in early September 2022 and flooded the layouts on the valley floors below them; Yelahanka lake flooded Kendriya Vihar in November 2021 and three times in October 2024; and the Hulimavu lake bund breached in November 2019. This chapter gives the design rules that protect that storage. It does not replace the Revenue, Minor Irrigation, KTCDA and local-body procedures that record and protect waterbodies in law.