About this draft
Status. This is Draft v1.0 of the Keralam Stormwater Design Manual. It was prepared by Neer as a proposed stormwater design standard for Keralam.
Not adopted. This Manual has not been adopted, notified or endorsed by the Government of Keralam or by any of its departments, local bodies or agencies. Where it names a body, such as LSGD, the Irrigation Department, KSDMA or a local body, it describes the role that body would have if the Manual were adopted. It does not say the body has agreed to that role.
Supplements. The Manual carries two supplements for places that lie outside the State but share its coast, climate and language. Supplement S01 covers Mahé, a town on the north Keralam coast that is part of the Union Territory of Puducherry; it has not been adopted, notified or endorsed by the Government of Puducherry. Supplement S02 covers the Lakshadweep islands, which lie off the Keralam coast; it has not been adopted, notified or endorsed by the Lakshadweep Administration. What this notice says of the Manual applies to each supplement.
Name of the State. The State was renamed from Kerala to Keralam by the Kerala (Alteration of Name) Act, 2026 (Act 18 of 2026), in force from 25 August 2026. This Manual uses Keralam for the State. Acts, rules, bodies and documents are cited by the names under which they were made or published, such as the Kerala Municipality Building Rules, 2019.
No legal force. Until a competent authority adopts it, with or without changes, this Manual has no legal force. The development rules, drainage standards and approval conditions in force continue to apply.
Use with care. Clauses and values may change after review. Designers remain responsible for their designs and for checking the data they use. Neer accepts no liability for decisions made on the basis of this draft.
Disclosure. Neer publishes the India Flood Atlas, a national map of modelled 1% AEP flood depth. Clause 6.11.3 names it as one example of a regional map that an Approving Authority may adopt for floor levels. The Manual does not require the Atlas; any map adopted under Clause 7.3.4 may be used.
Comments. Comments and corrections are welcome at info@neer.ai.
Preface
Keralam's cities and towns flood for three reasons. The floods of August 2018 showed all three at once, and the waterlogging of Kochi and Thiruvananthapuram in 2019, 2023 and 2024 shows them in ordinary monsoon storms.
- Inadequate drain capacity. Drains are too small for the rain they receive. Many were sized for generalised intensities far below the short bursts now recorded, such as the 103 mm that fell in one hour at Kalamassery, Kochi, on 28 May 2024. Roofs, roads and paving now send more water to them, and faster.
- Lost storage. The backwaters (kayals), paddy wetlands and kulams that once held storm water have been reclaimed, filled or cut off from the drains. Vembanad lake is reported to have lost most of its water-holding capacity, and the built-up area of the Periyar basin grew about 450% between 1985 and 2015. The water they used to store now runs into streets and homes.
- Blocked outfalls. Drains empty into the sea, rivers, canals and backwaters. When a spring tide, a high backwater level or a sand bar at the river mouth (pozhi) closes the outfall, water backs up, and even a well-sized drain cannot empty. In 2018 the outlets to the sea, including the Thottappally spillway, could not carry the flood away while a perigean spring tide held sea levels high.
In the midlands and high ranges a further hazard sits alongside these. The deadliest events of 2019, 2020 and 2024 were landslides and debris flows on saturated slopes. Drains cannot carry them; development has to keep away from them, and runoff must not be concentrated onto steep or unstable ground.
National guidance sizes public drains but does not control the runoff that new building adds. This Manual makes stormwater a condition of development approval. Every development above a modest size must:
- hold frequent rainfall on site;
- release the large storms no faster than the undeveloped land did, or slower where catchments already flood; and
- show that its outfall still works when the tide or the backwater is high.
The Manual also sets how public drains, roads, canals, kulams and basin-wide master plans are designed, so that private sites and public works aim at the same standard.
The Manual draws on leading stormwater standards from India and abroad. Each is adapted to Keralam's long south-west monsoon, saturated soils, backwaters and paddy wetlands, Kuttanad polders, laterite midlands, high water tables, landslide-prone high ranges and tidal, backwater-locked and sand-barred outfalls.
- National base. The CPHEEO Manual on Storm Water Drainage Systems (2019). This Manual builds on it and sets higher standards where it allows a State to do so. IRC road-drainage codes and the NDMA urban flood guidelines are also used.
- Overall structure. Kansas City Metro APWA Section 5600 (Version 2025.01), the most recent comprehensive regional standard. It supplies the preserve, retain, detain, convey and maintain sequence and the required retention volume.
- Design rainfall. Frequency analysis of hourly rainfall by the National Institute of Hydrology (NIH), Roorkee.
- Tropical and coastal practice. The PUB Singapore Code of Practice on Surface Water Drainage (7th ed., 2025), for the fixed-coefficient route for small sites, drainage reserves and coastal platform levels. Malaysia's MSMA 2 (2012), for monsoon design storms and simplified on-site detention.
- Runoff reduction and treatment. The Georgia Stormwater Management Manual (2016), for runoff reduction and downstream analysis. CIRIA C753 The SuDS Manual (2015), for the treatment train. The Mile High Flood District criteria manual, for outlet and storage design.
- Local rules. The Kerala Municipality and Panchayat Building Rules (KMBR/KPBR 2019), the Kerala Conservation of Paddy Land and Wetland Act, 2008, and the CRZ Notification 2019 as applied in Keralam, which this Manual follows or, where disclosed, makes stricter.
Why this Manual is needed
India has no uniform stormwater design standard. The CPHEEO Manual on Storm Water Drainage Systems (2019) is the country's first manual dedicated to storm water drainage, but it is advisory. The Ministry of Housing and Urban Affairs lists it among advisory guidelines and treats urban flooding as a matter for State Governments and urban local bodies. None of the national rules or State building rules reviewed for this Manual makes runoff control a condition of building approval. KMBR/KPBR 2019 and the Model Building Bye-Laws 2016 require rainwater harvesting, and KMBR/KPBR require half of a plot's open space to stay permeable, but they set no detention volume and no release rate.
The national documents leave key values open, or give different answers.
- Return periods. CPHEEO recommends 5 years for drains in Class I cities and 2 years elsewhere, and lets a State committee adopt higher values. A 2023 CPHEEO presentation shows a different table. IRC:SP:50-2013 suggests 1–2 years for urban road drains; IRC:SP:42-2014 suggests 25 years. An engineer designing a drain on a Kochi arterial road can cite 1, 5 or 25 years, depending on the code chosen.
- Detention. CPHEEO describes limiting peak outflow to pre-development rates as general practice. It uses no "shall" and names no storm frequencies.
- Climate. The NDMA Urban Flooding Guidelines (2010) call for detention and retention facilities and for rainfall curves adjusted for climate change, but give no sizing rule or return period.
- Design rainfall. No national document gives design rainfall that a designer can apply directly to a given town. Each project chooses its own source. Kochi's drains are reported to be designed for generalised intensities of 12–20 mm/h, with no stated return period.
Keralam has no drainage design standard of its own. Research for this Manual found no Keralam design standard, State IDF relationship or departmental circular that fixes return periods or design rainfall for urban drains, and no Keralam city with a published stormwater drainage master plan. CAG found in 2021 that the State had no flood plain zoning law and had not demarcated its flood plains. In 2025 it found that Kochi had no drainage master plan or drainage map, and that AMRUT stormwater works in Keralam's nine mission cities had covered only 5.59% of the identified gap in the drain network.
So each region and each local body interprets the central manual its own way. Corporations, municipalities, panchayats, consultants and funding agencies fill the gaps differently. Two drains on the same street, built by different agencies, can be sized for different storms from different rainfall sources. Neighbouring local bodies in one river basin can work to different standards, though the water does not stop at their boundary. And a reviewer has no common basis against which to check a design.
What this Manual does about it. It turns those open choices into one State standard:
- one source and method for design rainfall (Chapter 2);
- named return periods for every drainage element (Chapters 2 and 6);
- a required pre- versus post-development rule for private sites (Chapter 4);
- a required tailwater check for outfalls (Chapter 5); and
- basin-wide master plans, so that neighbouring local bodies plan together (Chapter 11).
It uses the route the CPHEEO manual itself provides: a State may adopt standards higher than the national values (CPHEEO 2019, Table 4.1, Note 2). A Municipal Corporation, Municipality, Grama Panchayat or development authority can still adopt a stricter standard (Chapter 1).
Sources: CPHEEO (2019) Part A §4.4–4.5 and Table 4.1; CPHEEO presentation to CSE (August 2023); IRC:SP:50-2013 §6; IRC:SP:42-2014 §6; NDMA (2010) Urban Flooding Guidelines; MoHUA Model Building Bye-Laws (2016); Lok Sabha Unstarred Question 1847 (July 2026); KMBR/KPBR 2019; CAG Report No. 6 of 2021 (Kerala floods); CAG performance audit of AMRUT in Kerala (2025), Chapter IV; CPPR (2024).
How to use this Manual
Clauses and commentary. Numbered clauses (for example 4.5.2) are the requirements of this Manual and use "shall". Paragraphs headed Commentary explain the reason for a clause and cite its precedent. They are guidance, not requirements. Where a value has no direct precedent elsewhere, the commentary says so and explains why this Manual sets it.
Return periods. Storms are described both by annual exceedance probability (AEP) and by return period. For example, "1% AEP (100-yr)" means a storm with a 1-in-100 chance of being equalled or exceeded in any year.
Illustrative values. Worked examples and figures marked "Illustrative — not design values" show method and scale only. Design values come from the sources set in Chapter 2.
Annexes and forms. Each chapter lists the annexes and forms it relies on. They follow the chapters, grouped by chapter, and hold the forms to submit, worked examples, templates, model text and standard drawings. Annexes that need data not yet collected are marked To be prepared. They say what they will contain, and the clause that depends on them states the rule that applies in the meantime.
Supplements. The supplements follow the annexes. Each applies the Manual to a Union Territory area that adjoins or lies off the Keralam coast, and states where its rules differ.
Figures. All figures are original drawings prepared for this Manual. Where a figure follows a published concept, its caption credits the source.
Where to start.
| If you are… | Read first |
|---|---|
| A developer or architect | Chapter 1 (does it apply?), Chapter 4 (what to provide), Chapter 10 (what to submit) |
| A design engineer | Chapters 2–6, then 8 and 9 |
| A local body or approving authority | Chapters 1, 10 and 11 |
| A planner or waterbody manager | Chapters 7 and 11 |
Contents
Supplements
| No. | Title | Status |
|---|---|---|
| S01 | Mahé (Union Territory of Puducherry) | Not adopted by the Government of Puducherry |
| S02 | Lakshadweep | Not adopted by the Lakshadweep Administration |
List of tables
List of figures
Abbreviations
| Abbreviation | Meaning |
|---|---|
| AEP | Annual exceedance probability |
| AMC | Antecedent moisture condition |
| AMRUT | Atal Mission for Rejuvenation and Urban Transformation |
| APWA | American Public Works Association |
| ARF | Areal reduction factor |
| BSMP | Basin Stormwater Master Plan |
| CAG | Comptroller and Auditor General of India |
| CN | Curve number (SCS/NRCS method) |
| CPHEEO | Central Public Health and Environmental Engineering Organisation |
| CRZ / CZMP | Coastal Regulation Zone / Coastal Zone Management Plan |
| CSE | Centre for Science and Environment |
| CWC | Central Water Commission |
| DDMA | District Disaster Management Authority |
| FTL / MWL | Full tank level / maximum water level |
| GCDA | Greater Cochin Development Authority |
| HAT / MHWS | Highest astronomical tide / mean high water springs |
| HGL | Hydraulic grade line |
| HSG | Hydrologic soil group |
| IDF | Intensity–duration–frequency |
| IMD | India Meteorological Department |
| IRC | Indian Roads Congress |
| KCZMA | Kerala Coastal Zone Management Authority |
| KMBR / KPBR | Kerala Municipality Building Rules, 2019 / Kerala Panchayat Building Rules, 2019 |
| KSDMA | Kerala State Disaster Management Authority |
| KSEB | Kerala State Electricity Board |
| KWA | Kerala Water Authority |
| LSGD | Local Self Government Department, Keralam |
| LSGI | Local self-government institution (Municipal Corporation, Municipality or Grama Panchayat) |
| MoHUA | Ministry of Housing and Urban Affairs |
| NDMA | National Disaster Management Authority |
| NE monsoon / OND | North-east monsoon, October–December |
| NIH | National Institute of Hydrology, Roorkee |
| PSD | Permissible site discharge |
| RRV | Required retention volume |
| RWH | Rainwater harvesting |
| SLA | Sea-level allowance |
| SW monsoon / JJAS | South-west monsoon, June–September |
| TRIDA | Thiruvananthapuram Development Authority |
| ULB | Urban local body |
| WQv | Water quality volume |