Annexes to Chapter 3Hydrologic Methods
These annexes support Chapter 3. Annex 3C sets out benchmark test problems for software acceptance, and Forms 3-1 and 3-2 are the submittal forms required by Clause 3.17. Annexes 3A, 3B, 3D and 3E need survey, gauging or published report data that this draft does not yet contain; each gives the intended layout and the interim rule of Chapter 3 that applies until it is published. The forms are draft forms and have no statutory status.
Annex 3A — Rajasthan soil series to HSG lookup; seasonal high water table map
Supports Clauses 3.7 and 3.10 of Chapter 3.
To be prepared. This annex will contain (a) a lookup from each soil series mapped in Rajasthan to its hydrologic soil group (HSG), in both the drained and the undrained state, and (b) a map of the depth to the seasonal high groundwater table in the south-west monsoon (June–September). It needs NBSS&LUP and Central Arid Zone Research Institute (CAZRI, for the arid zone) or the Rajasthan Department of Agriculture (soil survey) [TBC] series maps with their scales, measured saturated hydraulic conductivity and depth to an impermeable layer for each series, and observation-well records from the Central Ground Water Board and the Ground Water Department, supplemented by piezometers in the Ghaggar–canal plains of Sri Ganganagar and Hanumangarh, the old city of Jodhpur, the floodplains of the Chambal, the Banas, the Luni and the Ghaggar, the black-soil plains of Hadoti, and the foreshores of the lakes and talabs of Udaipur, Ajmer and Jaipur. Until it is published, use the interim rules of Chapter 3: assign HSG from measured saturated hydraulic conductivity and depth to an impermeable layer or water table by the criteria of NEH Part 630, Ch. 7 (Clause 3.7.2); verify it by site infiltration tests wherever retention relies on infiltration (Clause 3.7.3); take the seasonal high water table from site piezometers, trial pits or the nearest observation well (Clause 3.10.2); and assign HSG D wherever that level is within 0.6 m of the ground surface (Clause 3.10.1).
Table 3A.1 — Soil series to HSG lookup (layout)
| Soil series | District(s) | Taxonomic class | Surface texture | Saturated hydraulic conductivity (mm/h) | Depth to impermeable layer (m) | HSG, drained | HSG, undrained | Source map and scale |
|---|---|---|---|---|---|---|---|---|
Table 3A.2 — Seasonal high water table, by mapping unit (layout)
| Mapping unit or grid cell | Observation wells used | Years of June–September record | Highest June–September level below ground (m) | Within 0.6 m of ground (Clause 3.10.1)? | Data source |
|---|---|---|---|---|---|
Annex 3B — Rajasthan CN calibration and supplementary land covers (dune and hummocky sand, calcrete pans and saline depressions, cracked black-soil fallow, talab, johad, nadi and khadin beds, Aravalli rock and thin soils, desert scrub and grassland)
Supports Clauses 3.8 and 3.15 of Chapter 3.
To be prepared. This annex will contain (a) curve numbers calibrated against observed rainfall and runoff in Rajasthan catchments, compared with the TR-55 values of Table 3.5, and (b) curve numbers for land covers that Table 3.5 does not list: the dune and hummocky sands of the Thar, shifting or stabilised, bare or under sparse grass; the calcrete (kankar) and petrocalcic pans and the saline and gypsum depressions of the arid zone, which shed water from a few centimetres of soil; the black-soil fallow of Hadoti while it is still dry and cracked early in the monsoon; the beds of talabs, johads, nadis and khadins and the foreshores of lakes such as the Pichola, Fateh Sagar and Ana Sagar that are dry or cultivated at the start of a storm; the bare or nearly bare rock and thin soils of the Aravalli hills, from Mount Abu and Udaipur to Ajmer, Jaipur and Alwar; and the desert scrub and grassland of the west and the dry forest of the Aravallis. It needs paired rainfall–runoff records for small gauged catchments of known cover and soil, from WRD gauging sites, agricultural research stations and tank gauges, analysed by event and by antecedent moisture. Until it is published: the pre-development reference stays open space in good condition for every site (Clause 3.3.2), so these covers do not enter the pre-development run; for off-site existing conditions, use the nearest Table 3.5 or TR-55 cover row, including the cultivated rows (Clause 3.8.3(c)), and state the row chosen and the reason on Form 3-1; land under standing water at the start of the design storm is modelled as water surface with no losses (Table 3.5; Clause 3.10.4(b)). Any departure from these defaults requires calibration under Clause 3.15 (Clause 3.15.1(d)).
Table 3B.1 — Supplementary land covers, AMC II (layout)
| Cover type | HSG A | HSG B | HSG C | HSG D | Ia ratio | Basis (catchments, events, years) |
|---|---|---|---|---|---|---|
| Dune and hummocky sand of the Thar, shifting or stabilised, bare or under sparse grass | ||||||
| Calcrete (kankar) or petrocalcic pan, gypsum layer or saline depression of the arid zone | ||||||
| Black-soil fallow of Hadoti, dry and cracked at the start of the storm (before 15 August) | ||||||
| Talab, johad, nadi or khadin bed, or lake foreshore, dry or cultivated at the start of the storm | ||||||
| Bare or nearly bare Aravalli rock and thin soils | ||||||
| Desert scrub and grassland of the west, and dry forest of the Aravallis | ||||||
| Other (state) |
Table 3B.2 — CN calibration catchments (layout)
| Catchment | District | Area (km²) | Dominant HSG and cover | Events used | Table 3.5 CN | Calibrated CN | Calibrated ÷ Table 3.5 |
|---|---|---|---|---|---|---|---|
Annex 3C — Benchmark test problems for software acceptance
Supports Clauses 3.5, 3.6, 3.8, 3.9, 3.11, 3.12 and 3.16 of Chapter 3.
Purpose. Software not listed in Clause 3.16.1 shall reproduce the results of the five problems below (Clause 3.16.3). Each problem is fully specified and uses only the methods and tables of Chapter 3, so every answer can be checked by hand. The acceptance tolerance is ±5% on each tabulated result, the equivalence threshold of Clause 3.16.2; for closed-form results (Problems 3C-1 to 3C-4), software should agree to the rounding shown. The submittal shall report the software result next to each answer below.
Illustrative — not design values. The inputs (areas, intensities, rainfall depths, slopes and the basin) are chosen for testing only. They are not design data for any site.
Problem 3C-1 — Rational Method peak (Clause 3.5)
Inputs. A 2.0 ha catchment draining to one inlet: 1.2 ha concrete paving and roofs, C = 0.90 (Table 3.2, upper half of 0.80–0.95); 0.8 ha lawns on sandy soil, average slope, C = 0.15 (Table 3.2, upper half of 0.10–0.15). Design AEP 1% (100-yr). Rainfall intensity at Tc, including the climate factor: i = 120 mm/h.
Part (b): a separate 0.5 ha fully paved catchment, C = 0.90, design AEP 1%, i = 150 mm/h.
Table 3C.1 — Problem 3C-1 solution
| Step | Calculation | Result |
|---|---|---|
| Composite C (Clause 3.5.4) | (1.2 × 0.90 + 0.8 × 0.15) / 2.0 | 0.60 |
| Frequency factor (Table 3.3) | 1% AEP | Cf = 1.25 |
| C · Cf (≤ 1.0) | 0.60 × 1.25 | 0.75 |
| Peak flow (Clause 3.5.1) | 0.75 × 120 × 2.0 / 360 | Q = 0.500 m³/s |
| Part (b): C · Cf | 0.90 × 1.25 = 1.125, capped at 1.0 (Clause 3.5.3) | 1.00 |
| Part (b): peak flow | 1.00 × 150 × 0.5 / 360 | Q = 0.208 m³/s |
Problem 3C-2 — Time of concentration by the segment method (Clause 3.6)
Inputs. Pre-development flow path: sheet flow over greenfield, n = 0.15 (Clause 3.6.3), L = 30 m, S = 0.01; P2 (50% AEP 24-hour rainfall, no climate factor) = 80 mm. Shallow concentrated flow, unpaved, L = 200 m, S = 0.01. Channel flow, L = 400 m, bank-full velocity V = 1.0 m/s (given).
Table 3C.2 — Problem 3C-2 solution
| Segment | Calculation | Travel time |
|---|---|---|
| Sheet flow (Clause 3.6.2(a)) | 0.091 × (0.15 × 30)^0.8 / (80^0.5 × 0.01^0.4) = 0.2138 h | 12.83 min |
| Shallow concentrated (Clause 3.6.2(c)) | V = 4.918 × 0.01^0.5 = 0.4918 m/s; 200 / (3,600 × 0.4918) = 0.1130 h | 6.78 min |
| Channel (Clause 3.6.2(d)) | 400 / (3,600 × 1.0) = 0.1111 h | 6.67 min |
| Tc (Clause 3.6.1; ≥ 10 min) | 12.83 + 6.78 + 6.67 | 26.27 min |
| Lag (Clause 3.6.5) | 0.6 × 26.27 | 15.76 min |
Problem 3C-3 — SCS-CN runoff depth, AMC and Ia sensitivity (Clause 3.8)
Inputs. Pre-development reference on HSG C: CN = 74 at AMC II (Table 3.5), all pervious. Cumulative rainfall P = 100 mm; second case P = 25 mm.
Table 3C.3 — Problem 3C-3 solution
| Case | S (mm) | Ia (mm) | Runoff Q (mm), P = 100 mm | Runoff Q (mm), P = 25 mm |
|---|---|---|---|---|
| (a) AMC II, Ia = 0.2S: S = 25,400 / 74 − 254 | 89.24 | 17.85 | 39.38 | 0.53 |
| (b) AMC III, Ia = 0.2S: CN(III) = 23 × 74 / (10 + 0.13 × 74) = 86.75 | 38.80 | 7.76 | 64.93 | — |
| (c) AMC II, Ia = 0.05S: S0.05 = 25.4 × 1.33 × (89.24 / 25.4)^1.15 | 143.31 | 7.17 | 36.49 | 1.97 |
Runoff is Q = (P − Ia)² / (P − Ia + S). Case (c) gives less runoff than case (a) at 100 mm but more at 25 mm, as Clause 3.8.5 and Figure 3.3 describe.
Problem 3C-4 — Separate vs composite impervious representation, and SCS unit hydrograph peak (Clauses 3.9 and 3.11.2)
Inputs, part (a). A site that is 50% directly connected impervious (CN 98) and 50% open space on HSG B (CNp = 61), AMC II, Ia = 0.2S, P = 25 mm.
Inputs, part (b). A sub-area of A = 2.5 km² with Tc = 1.0 h and computation interval Δt = 0.1 h.
Table 3C.4 — Problem 3C-4 solution
| Step | Calculation | Result |
|---|---|---|
| (a) Impervious half (Clause 3.9.2) | S = 5.18 mm, Ia = 1.04 mm; Q = 23.96² / (23.96 + 5.18) | 19.70 mm |
| (a) Pervious half | S = 162.39 mm, Ia = 32.48 mm > P | 0 mm |
| (a) Area-weighted runoff, separate sub-areas | 0.5 × 19.70 + 0.5 × 0 | 9.85 mm |
| (a) Composite CN (Clause 3.9.4) | 61 + 0.50 × (98 − 61) | 79.5 |
| (a) Runoff with composite CN | S = 65.50 mm, Ia = 13.10 mm; Q = 11.90² / (11.90 + 65.50) | 1.83 mm |
| (b) Interval check (Clause 3.11.3(a)) | 0.133 × 1.0 = 0.133 h ≥ Δt = 0.1 h | satisfied |
| (b) Lag and time to peak (Clause 3.11.2) | tL = 0.6 × 1.0 = 0.60 h; tp = 0.1 / 2 + 0.60 | tp = 0.65 h |
| (b) Unit hydrograph peak, Q = 1 mm | 0.208 × 2.5 × 1 / 0.65 | qp = 0.800 m³/s per mm |
Part (a) reproduces the comparison in the commentary to Clause 3.9 (about 9.9 mm vs 1.8 mm).
Problem 3C-5 — Level-pool (modified Puls) storage routing (Clause 3.12.1)
Inputs. A detention basin with vertical sides and plan area 500 m², with the stage–storage–discharge relationship of Table 3C.5. Triangular inflow hydrograph: 0 at t = 0, rising linearly to 0.50 m³/s at t = 30 min, falling linearly to 0 at t = 90 min. Basin empty at t = 0. Routing interval Δt = 10 min (600 s). No tailwater.
Table 3C.5 — Problem 3C-5 stage–storage–discharge relationship
| Stage (m) | Storage S (m³) | Outflow O (m³/s) |
|---|---|---|
| 0.0 | 0 | 0.00 |
| 0.5 | 250 | 0.05 |
| 1.0 | 500 | 0.10 |
| 1.5 | 750 | 0.15 |
| 2.0 | 1,000 | 0.20 |
| 2.5 | 1,250 | 0.25 |
Method. The storage-indication equation is (I1 + I2) + (2S1/Δt − O1) = (2S2/Δt + O2). The table gives O = S / 5,000 (S in m³, O in m³/s), so 2S/Δt + O = 17.667 O and 2S/Δt − O = 15.667 O, and each step is O2 = [(I1 + I2) + 15.667 O1] / 17.667. Software interpolating linearly in Table 3C.5 shall give the same result.
Table 3C.6 — Problem 3C-5 routed outflow
| Time (min) | Inflow I (m³/s) | Outflow O (m³/s) | Storage (m³) | Stage (m) |
|---|---|---|---|---|
| 0 | 0.0000 | 0.0000 | 0.0 | 0.000 |
| 10 | 0.1667 | 0.0094 | 47.2 | 0.094 |
| 20 | 0.3333 | 0.0367 | 183.3 | 0.367 |
| 30 | 0.5000 | 0.0797 | 398.4 | 0.797 |
| 40 | 0.4167 | 0.1226 | 612.8 | 1.226 |
| 50 | 0.3333 | 0.1511 | 755.7 | 1.511 |
| 60 | 0.2500 | 0.1670 | 835.2 | 1.670 |
| 70 | 0.1667 | 0.1717 | 858.6 | 1.717 |
| 80 | 0.0833 | 0.1664 | 832.1 | 1.664 |
| 90 | 0.0000 | 0.1523 | 761.5 | 1.523 |
| 120 | 0.0000 | 0.1062 | 531.1 | 1.062 |
| 180 | 0.0000 | 0.0517 | 258.3 | 0.517 |
Results. Peak outflow 0.172 m³/s at 70 min; peak storage 859 m³; peak stage 1.72 m. The inflow peak of 0.50 m³/s is reduced to 34% of its value.
Table 3C.7 — Benchmark results to be reported by the applicant
| Problem | Result | Benchmark | Software result | Difference (%) | Within ±5%? |
|---|---|---|---|---|---|
| 3C-1 | Q, main case (m³/s) | 0.500 | |||
| 3C-1 | Q, part (b) (m³/s) | 0.208 | |||
| 3C-2 | Tc (min) | 26.27 | |||
| 3C-3 | Q, case (a), P = 100 mm (mm) | 39.38 | |||
| 3C-3 | Q, case (b), P = 100 mm (mm) | 64.93 | |||
| 3C-3 | Q, case (c), P = 100 mm (mm) | 36.49 | |||
| 3C-3 | Q, case (c), P = 25 mm (mm) | 1.97 | |||
| 3C-4 | Runoff, separate sub-areas (mm) | 9.85 | |||
| 3C-4 | Runoff, composite CN (mm) | 1.83 | |||
| 3C-4 | qp (m³/s per mm) | 0.800 | |||
| 3C-5 | Peak outflow (m³/s) | 0.172 | |||
| 3C-5 | Peak storage (m³) | 859 |
Annex 3D — Peak rate factor study for flat coastal land
Supports Clauses 3.11.5 and 3.15 of Chapter 3.
Not required in Rajasthan. Rajasthan is landlocked and has no flat coastal plain, so no land in the State meets Clause 3.11.5(a), and the standard factor 484 (PRF′ = 0.208) applies to all land (Clause 3.11.5). The interdunal plains of the Thar, the canal command of Sri Ganganagar and Hanumangarh and the Sambhar basin are flat in places but are not coastal plain, and much of that land has no defined outfall; its slow response is represented by storage and backwater (Clauses 3.10.4 and 3.12.4) and by the volume rule of Clause 4.12.7, not by a lower peak rate factor. The annex and the layout of Table 3D.1 are kept only so that the annex numbering is unchanged.
Table 3D.1 — Calibrated peak rate factors (layout)
| Catchment | Area (km²) | Mean slope (m/m) | Drainage condition | Events used | Calibrated PRF (US customary) | PRF′ (SI) | Range of applicability |
|---|---|---|---|---|---|---|---|
Annex 3E — CWC SUH parameters for subzones 1(a), 1(b), 1(e) and 3(a), with worked example
Supports Clauses 3.4.3 and 3.11.4 of Chapter 3.
To be prepared. This annex will tabulate, for CWC subzones 1(a) (Luni), 1(b) (Chambal), 1(e) (Upper Indo-Ganga Plains) and 3(a) (Mahi and Sabarmati), the regression relationships for the synthetic unit hydrograph parameters, the design storm duration, loss rate, base flow, areal reduction and time distribution, each with its reference to the Flood Estimation Report, and a worked example for one catchment. It needs the four CWC Flood Estimation Reports that cover Rajasthan: the Luni subzone 1(a) (L/20/1992; the cover reads L-20/1993), of whose 205,624 km² some 202,422 km² lie in Rajasthan, about 59% of the State, covering the Thar, the Luni basin and Shekhawati, including Jodhpur, Bikaner, Jaisalmer, Barmer, Balotra, Pali, Jalore, Sirohi and Mount Abu, Nagaur, Churu, Sikar and Sri Ganganagar and the west of Ajmer and Jaipur districts; the Chambal subzone 1(b) (C/16/1988), which covers Jaipur, Ajmer (east) and Nasirabad, Tonk, Bhilwara, Chittorgarh, Rajsamand, the north of Udaipur, Kota, Bundi, Baran, Jhalawar, Sawai Madhopur, Karauli and Dholpur; the Upper Indo-Ganga Plains subzone 1(e), approved at the 40th meeting of the Planning and Co-ordination Committee on 23–24 July 1984, whose design-office report number is not on the scanned copy read for this Manual [TBC], and which covers the eastern border of the State, including Alwar, Bhiwadi, Bharatpur and Deeg; and the Mahi and Sabarmati subzone 3(a) (MS/13/1986, printed "M5/13/1986"), which covers Banswara, Dungarpur and the south of Udaipur and Pratapgarh (see the References of Chapter 3); with the time-distribution and areal reduction tables of subzone 1(a), which are garbled in the copy read, the names and areas of the seven bridge catchments on which the 1(a) unit hydrograph rests, the printing conflicts listed in the note to Table 3E.1, and the subzone boundaries within Rajasthan, including those at Jaipur and Ajmer (1(a)/1(b)), Udaipur (1(b)/3(a)) and Jhunjhunu, Sri Ganganagar and Hanumangarh (1(a)/1(e)), still to be confirmed on the reports' page images and index maps [TBC], transcribed and checked against the published reports, and a catchment with physiographic parameters measured from survey or a DEM. Until it is published, take all SUH inputs directly from the applicable Flood Estimation Report (Clause 3.11.4(a)), apply the 24-hour design rainfall of Clauses 2.3.3(b) and 2.7.3 with the climate factor of Clause 2.8 (Clause 3.11.4(b)), report the SUH result alongside the HEC-HMS or SWMM result for the existing natural condition (Clause 3.11.4(c)), and, where the hydrograph model gives a lower 1% AEP peak, either justify it by calibration under Clause 3.15 or adopt the SUH peak (Clause 3.11.4(d)).
Table 3E.1 — SUH relationships by subzone (layout)
| Parameter | Symbol | Unit | Subzone 1(a) relationship | Subzone 1(b) relationship | Subzone 1(e) relationship | Subzone 3(a) relationship |
|---|---|---|---|---|---|---|
| Time from centre of unit rainfall to peak | tp | h | tp = 0.257 A^0.409 S^0.432, as printed, with A in km² (the positive exponent on S lengthens the lag on steeper catchments; see the note) [TBC] | tp = 0.339 (L/√S)^0.826 | tp = 1.858 qp^−1.038 | tp = 0.433 (L/√S)^0.704 |
| Peak discharge per unit area | qp | m³/s per km² | qp = 2.165 tp^−0.893 | qp = 1.251 tp^−0.610 (relationship table; the step-by-step text prints 1.215 [TBC]) | qp = 2.030 (L/√S)^−0.649 | qp = 1.161 / tp^0.635 |
| Width of UH at 50% of peak | W50 | h | W50 = 2.654 qp^−0.921 | W50 = 2.215 qp^−1.034 | W50 = 2.217 qp^−0.990 | W50 = 2.284 / qp^1.00 |
| Width of UH at 75% of peak | W75 | h | W75 = 1.672 qp^−0.816 | W75 = 1.191 qp^−1.057 | W75 = 1.477 qp^−0.876 | W75 = 1.331 / qp^0.991 |
| Width of rising limb at 50% of peak | WR50 | h | WR50 = 1.245 qp^−0.571 | WR50 = 0.834 qp^−1.077 | WR50 = 0.812 qp^−0.907 | WR50 = 0.827 / qp^1.023 |
| Width of rising limb at 75% of peak | WR75 | h | WR75 = 0.816 qp^−0.559 | WR75 = 0.502 qp^−1.065 | WR75 = 0.606 qp^−0.791 | WR75 = 0.561 / qp^1.037 |
| Base width of UH | TB | h | TB = 6.299 tp^0.612 | TB = 6.662 tp^0.613 | TB = 7.744 tp^0.779 | TB = 8.375 tp^0.512 |
| Unit duration | tr | h | 1 | 1 | 2 | 1 |
| Design storm duration | TD | h | Trial durations from 1.1 tp to TB; the one giving the highest peak is adopted (the report finds it "not possible to recommend adoption of design storm duration due to scanty data") | TD = 1.1 tp, or TD = 0.539 (L/√S)^0.724, rounded to the nearest hour (p. 40) | TD = 1.1 tp, limited to 24 h | TD = TB = 5.452 (L/√S)^0.360, rounded to the nearest whole hour |
| Design loss rate | — | mm/h | 5 (printed "0.5 cm/hr"; modal value 0.41 cm/h of 48 events) | 1.7 (printed "0.17 cm/hr"; modal value) | 3.0 | 4.5 (printed "0.45 cm/hr", modal value of 148 events); or, for average conditions, I = 0.56 R^0.66 / TD^0.59, with I in cm/h, TD in h and R the storm rainfall in cm as defined in the report [TBC] |
| Design base flow | — | m³/s per km² | 0.05 | qb = 0.207 A^−0.290, read by optical character recognition only [TBC] | 0.05 | qb = 0.109 / A^0.126, A in km² |
| Ratio of t-hour to 24-hour rainfall | — | — | 10-yr, adopted for all return periods: 1 h 0.36; 3 h 0.58; 6 h 0.72; 9 h 0.79; 12 h 0.85; 15 h 0.89; 18 h 0.94; 24 h 1.00 | 50-yr: 1 h 0.35; 3 h 0.53; 6 h 0.67; 9 h 0.74; 12 h 0.80; 15 h 0.85; 18 h 0.90; 24 h 1.00 (independent of return period from 5 years) | 50-yr: 1 h 0.340; 2 h 0.475; 3 h 0.560; 4 h 0.607; 5 h 0.647; 6 h 0.680; 9 h 0.770; 12 h 0.840; 15 h 0.890; 18 h 0.930; 24 h 1.000 | 50-yr: 1 h 0.36; 3 h 0.57; 6 h 0.70; 9 h 0.78; 12 h 0.85; 15 h 0.89; 18 h 0.93; 24 h 1.00 |
| Time distribution of 24-hour rainfall | — | cumulative fraction | Fig. 12 and Annex 4.1 of the report (average of 18 station curves for storms of 2–3, 4–6, 7–12, 13–18 and 19–24 hours); garbled in the copy read and not transcribed [TBC] | Fig. 12 of the report; not transcribed [TBC] | Average curves of Fig. 12; not transcribed [TBC] | [TBC] |
| Conversion of 1-day to 24-hour rainfall | — | factor | 1.15 | 1.15 | 1.15 | 1.15 |
| Areal reduction factor | ARF | — | Annex 4.2 and Fig. 11(a) of the report; the worked example interpolates 0.664 for 414 km² and TD = 5 h; the annex is garbled in the copy read [TBC] | ARF table of the report (p. 60), read by optical character recognition only: for 200 km², 66, 75, 81, 87 and 91%, and for 300 km², 60, 69, 76, 84 and 89%, with the durations of the columns not identified; to be read from the page image before use [TBC] | Table 6 of the report [TBC] | Table-6 of the report: 1 h, from 100% down to 60%; 3 h, to 68%; 6 h, to 74%, with increasing area, for areas up to 1,100 km² extrapolated to 2,500 km² [TBC] |
| 50-yr 24-hour point rainfall at Rajasthan towns | — | mm | Plate 9: Jodhpur about 200; Barmer about 180–200; Bikaner about 180; Sikar about 160–200; Sri Ganganagar and Nagaur about 160; Jaisalmer about 120–160 and Pokaran about 120; the Pali–Sirohi plains about 280; Mount Abu in a closed cell of about 440–480 | Plate 9: Jaipur about 200; Ajmer about 180–200; Udaipur about 200–220; Dholpur about 200; Kota, Tonk and Bhilwara about 240–280; Chittorgarh about 280; Jhalawar and Sawai Madhopur about 280–320 | Plate 9: Alwar about 200; Bharatpur about 220–240 | Plate 10: Udaipur City about 200 (on the subzone boundary); Banswara, Dungarpur and Deolia (Pratapgarh) about 280–320 |
| Catchment area for which the relationships apply | A | km² | Derived from seven gauged bridge catchments of 18–682 km² on the Aravalli fringe; not to be used outside that range or on dune or flat interdunal terrain (see the note) | 25–2,500; up to 5,000 "based on sound judgement" | 25–2,500, for "reasonably free catchments"; a "suitable increase" for steep foothill catchments | 25–1,500; up to 5,000 with judgement |
| Report reference | — | — | Table on p. 15, §3.5 and §3.6; worked example pp. 18–20; Annex 4.3 | Relationship table (p. 20), pp. 21–23, design storm (p. 40), §5.3, Table 7 | §3.9 (p. 42), §3.11 and §3.12 (p. 57), text table (p. 61) | Table-4 (p. 29), §3.11 and §4.1 |
Note: relationships as printed in the four CWC reports that cover Rajasthan (References of Chapter 3), read from scanned copies and checked against the page images except where marked as read by optical character recognition only; L is the length of the main stream in km, Lc the length to the point nearest the catchment centroid in km, S the equivalent slope in m/km and A the catchment area in km². The 50-yr point rainfalls were read by eye from the isopluvial plates and are good to about one contour. Subzone 1(a) is the weakest of the four, and it covers about 59% of the State. Its unit hydrograph rests on seven gauged bridge catchments of 18 to 682 km², with one to nine years of record each, all on the Aravalli fringe in Pali, Sirohi, Jalore and the Ajmer–Marwar railway sections; none of them lies in dune terrain, and the report's rain-gauge network "is very sparse, particularly over the north-western parts of the subzone". Its time-to-peak relationship carries a positive exponent on the slope, so that a steeper catchment is given a longer lag, which is physically odd, and the report does not recommend a design storm duration. Its worked example is the Mithri, a tributary of the Luni, at the Kherwa–Bhumadra road section (A = 414.00 km², L = 52.80 km, Lc = 28.00 km, S = 3.178 m/km): the relationship gives tp = 4.98 h, which the report adopts as "say 4.5 hrs" without explanation, with qp = 0.565 m³/s per km², TB = 15.92 h ("say 16 hrs") and a unit-graph peak of 233.91 m³/s; with a 50-yr 24-hour point rainfall of 25.00 cm, a 5-hour ratio of 0.680, an ARF of 0.664, a loss of 0.50 cm/h and a base flow of 20.70 m³/s it builds a design storm of TD = 5 h, and its figure prints a design flood peak of 1,950.16 m³/s, read by optical character recognition only [TBC]. This Manual therefore requires that the 1(a) relationships be used only for catchments of 18 to 682 km² with a defined channel on the Aravalli fringe, such as the Luni tributaries of Pali, Sirohi and Jalore and the nalas that enter Jodhpur from the hills; they shall not be used for dune or hummocky-sand terrain, for flat interdunal or canal-command land without a defined channel, or for the inland basins of the Thar, Shekhawati and Bikaner, where no FER method has been calibrated. There, Clause 3.11.4 has no FER benchmark: the catchment is modelled by the methods of Clause 3.4, its design rainfall is that of Chapter 2, and where it has no defined outfall its storage is set by the volume rule of Clause 4.12.7. In subzone 1(b) the relationship table gives qp = 1.251 tp^−0.610, but the step-by-step procedure in the text prints 1.215 (p. 21); the two differ by about 3% in qp, and this Manual uses the table. Subzone 1(e) uses a 2-hour unit graph, unlike the other three. The 3(a) report number is printed "M5/13/1986", probably a misprint for MS/13/1986. The design loss rates, 5 mm/h in 1(a), 4.5 in 3(a), 3.0 in 1(e) and 1.7 in 1(b), are φ-indices fitted to the floods of whole rural catchments, not soil infiltration capacities; the 1(a) value is a modal value from gravel and sand catchments on the Aravalli fringe, not from dunes, and the 1(b) value describes the black soils of Hadoti and the rest of the Chambal basin near saturation. They are not used to assign HSG (Clause 3.7) or to size infiltration practices (Chapter 4), and each rate shall be used only within its own subzone. The reports were derived from gauged rural catchments at railway and road bridges, none of them urban. In Rajasthan they apply to the rural nalas and streams that enter city limits, such as the Dravyavati and its feeders from the Nahargarh hills above Jaipur, the nalas that reach Jodhpur from the hills (within the 1(a) limits above), the Ayad and the feeders of the Udaipur lakes, the Chandralohi near Kota and the feeders of Ana Sagar at Ajmer; they are not a model of city catchments. Where a city catchment lies within 25–5,000 km², the SUH is computed only as the benchmark of its natural condition (Clause 3.11.4), and the catchment itself is designed by the methods of Clause 3.4 with the design rainfall of Chapter 2. The Chambal at Kota and Dholpur, the Banas, whose basin within the subzone is 48,577 km², and the Luni at Balotra, with a basin of 36,527 km², are far larger than the catchments of any report and are outside Clause 3.11.4 (Clause 3.4.5). Subzone boundaries, to be confirmed on the index maps of the reports [TBC]: Jaipur city lies on the 1(a)/1(b) boundary and drains south by the Dravyavati to the Dhund and on to the Banas, so its catchments are in 1(b), while the Sambhar, Phulera and Dudu side, which drains inland, is in 1(a); Ajmer straddles the Aravalli watershed, with Ana Sagar and the east draining to the Banas (1(b)) and Pushkar and the west to the Luni (1(a)); Udaipur lies on the 1(b)/3(a) boundary, its lake chain draining by the Ayad to the Berach and the Banas (1(b)) and its southern suburbs to the Som and the Mahi or to the Sabarmati (3(a)); Mount Abu and the Sirohi hills lie in 1(a) but carry its steepest rainfall gradient; Jhunjhunu, Sri Ganganagar and Hanumangarh lie at the 1(a)/1(e) boundary, and 1(a) values are used there only with a check against 1(e); Alwar and Bharatpur are in 1(e), and Dholpur and Karauli in 1(b). The subzone is chosen by the catchment's outfall, not by its district. Where a catchment drains across the boundary between two subzones, or its outfall lies within 5 km of one, as at Jaipur, Ajmer and Udaipur, this Manual requires the SUH to be computed with the parameters of each subzone and the higher 1% AEP peak to be adopted, unless calibration under Clause 3.15 supports the other. The plates are old and are exceeded at many stations: the heaviest 24-hour falls on record include 326.0 mm at Jaipur (Sanganer) on 19 July 1981, against a 100-yr plate value of about 240 mm, 412.3 mm at Ajmer on 10 June 2002, against about 220 mm, and 204.0 mm at Jaisalmer on 16 August 1973, against about 140–180 mm (IMD), and many of the records were set after the reports were published. The short storms are also stronger than the ratios suggest in the east: the 50-yr 1-hour depth fitted to 44 years of hourly IMD data at Jaipur, 93 mm (Ghate and Timbadiya, 2022), is about a third above the 50-yr 1-hour depth that the 1(b) plate and ratio give, about 70 mm, so Chapter 2 uses a checked station record of 25 years or more where one exists, and the plates and the ratios with the floors of Clause 2.3.6 elsewhere.
Table 3E.2 — Worked example outline (layout)
| Step | Content | Clause |
|---|---|---|
| 1 | Catchment area, main stream length, length to centroid and equivalent slope, from survey or DEM | 3.11.4(a) |
| 2 | SUH parameters from Table 3E.1 and the plotted unit hydrograph | 3.11.4(a) |
| 3 | Design storm duration, point and areal 24-hour rainfall with climate factor, time distribution | 3.11.4(a), (b) |
| 4 | Effective rainfall after the design loss rate; convolution with the SUH; base flow added | 3.11.4(a) |
| 5 | 1% AEP peak compared with the HEC-HMS or SWMM peak for the existing natural condition | 3.11.4(c), (d) |
Form 3-1 — Hydrologic Calculation Summary
Supports Clauses 3.4, 3.6, 3.7, 3.8, 3.10–3.13, 3.15–3.17 of Chapter 3.
Draft form — Rajasthan Stormwater Design Manual, Draft v1.0. One form per submittal. Attach the documents listed in Section H.
A. Project
Table 3F.1 — Form 3-1: project
| Field | Entry |
|---|---|
| A1. Project name and applicant | |
| A2. Location (village or ward, survey numbers, district) | |
| A3. Site area (ha) and number of points of comparison (POCs) | |
| A4. Catchment class: standard (Clause 2.11.2) or flood-sensitive (Clause 2.11.3) | |
| A5. Design Rainfall Sheet reference (Form 2-1) |
B. Method and software (Clauses 3.4, 3.11, 3.12, 3.16)
Table 3F.2 — Form 3-1: method and software
| Field | Entry |
|---|---|
| B1. Purpose of each calculation (conveyance, storage, comparison, catchment study) | |
| B2. Contributing area for each purpose (ha or km²) | |
| B3. Method used and the row of Table 3.1 that permits it | |
| B4. Reason for the choice of method | |
| B5. Software and version; engine and version for packages built on SWMM or HEC (Clause 3.16.1, 3.16.2) | |
| B6. For other software: benchmark results of Annex 3C attached (Table 3C.7) and the 5% comparison of Clause 3.16.2 | |
| B7. Runoff transform (Clause 3.11.1) | |
| B8. Computation interval Δt (h), with 0.133 Tc of the smallest sub-area and the hyetograph time step (Clause 3.11.3(a)) | |
| B9. Storage routing and channel routing methods (Clauses 3.12.1, 3.12.2) | |
| B10. Dynamic-wave routing required? If yes, which condition of Clause 3.12.4 | |
| B11. CWC SUH benchmark required (25–5,000 km², Clause 3.11.4)? Result reference | |
| B12. Continuous simulation required (Clause 3.13.1)? Record used and starting tank levels (Clause 3.13.5) | |
| B13. Calibration required (Clause 3.15.1)? Calibration report reference |
C. Soils and groundwater (Clauses 3.3.3(b), 3.7, 3.10)
Table 3F.3 — Form 3-1: soils and groundwater
| Field | Entry |
|---|---|
| C1. HSG source map, scale and lookup used (Clause 3.7.1, Annex 3A) or NEH Part 630, Ch. 7 assignment (Clause 3.7.2) | |
| C2. Infiltration tests: number, locations, depths, results (Clause 3.7.3) | |
| C3. Seasonal high water table: depth below ground and source (Clause 3.10.2) | |
| C4. Areas within 0.6 m assigned HSG D (Clause 3.10.1) | |
| C5. Disturbed pervious areas and HSG downgrade applied (Clause 3.3.3(b)) |
D. Parameters by sub-area and condition (Clauses 3.3, 3.5, 3.8, 3.9; Clause 3.17 item 4)
Table 3F.4 — Form 3-1: parameters by sub-area and condition
| Sub-area | Condition (pre / post) | Area (ha) | Impervious: roofs / paved / roads (ha) | DCIA (ha) | Disconnected (ha) | HSG | CN, AMC II | CN, AMC III (pervious part) | C and Cf (if Rational) | Tc (min) |
|---|---|---|---|---|---|---|---|---|---|---|
E. Time of concentration worksheet (Clause 3.6)
One worksheet per sub-area and condition.
Table 3F.5 — Form 3-1: time of concentration worksheet
| Segment | Flow type | Surface and n (Table 3.4) | L (m) | S (m/m) | P2 (mm) | V (m/s) | Tt (min) |
|---|---|---|---|---|---|---|---|
| 1 | Sheet | — | |||||
| 2 | Shallow concentrated | — | |||||
| 3 | Channel or pipe | — | |||||
| Tc (not less than 10 min) |
E1. Is the post-development Tc shorter than the pre-development Tc? If not, explain (Clause 3.6.6): ______
F. Rainfall and losses (Clauses 3.8.4, 3.8.5, 3.11.5, 3.12, 3.3.5)
Table 3F.6 — Form 3-1: rainfall, losses and starting levels
| Field | Entry |
|---|---|
| F1. AEPs and durations run; climate factor applied (Chapter 2) | |
| F2. AMC used for each duration (Clause 3.8.4) | |
| F3. Ia ratio for design runs; Ia = 0.05S sensitivity run made (Clause 3.8.5) | |
| F4. Peak rate factor used; if lower than 484, the Annex 3D value and the land it applies to (Clause 3.11.5) | |
| F5. Starting water level of each tank or waterbody, and its basis (Clauses 3.12.5, 3.13.5) | |
| F6. Off-site run-on: land use assumed for conveyance and for the comparison (Clause 3.3.5) | |
| F7. Incidental storage counted? If yes, the authority's acceptance (Clause 3.12.3) |
G. Departures
Table 3F.7 — Form 3-1: departures from Chapter 3
| No. | Clause departed from | Value used in place of the Chapter 3 value | Justification |
|---|---|---|---|
| 1 | |||
| 2 |
H. Attachments (Clause 3.17)
Table 3F.8 — Form 3-1: attachments
| Item | Attached (yes / no / not applicable) | Reference |
|---|---|---|
| H1. Catchment maps, pre- and post-development, with sub-areas, Tc flow paths, POCs and off-site run-on | ||
| H2. HSG map, water-table data and infiltration test results | ||
| H3. Parameter tables (Section D) and Tc worksheets (Section E) | ||
| H4. Design Rainfall Sheet (Form 2-1) and hyetographs | ||
| H5. Hydrograph tables and plots; stage–storage and stage–discharge tables; routed outflows; peak water levels | ||
| H6. Form 3-2 for each POC | ||
| H7. Calibration report (Clause 3.15) | ||
| H8. Native model input and output files (Clause 3.16.4) |
I. Statement by the responsible engineer (Clause 3.17 item 10)
I state that the methods and parameters of Chapter 3 of the Rajasthan Stormwater Design Manual (Draft v1.0) have been used in this submittal, and that every departure is listed and justified in Section G.
Table 3F.9 — Form 3-1: statement by the responsible engineer
| Field | Entry |
|---|---|
| Name | |
| Qualification and registration number | |
| Organisation | |
| Signature | |
| Date |
Draft form — Rajasthan Stormwater Design Manual, Draft v1.0.
Form 3-2 — Pre- vs Post-Development Comparison
Supports Clauses 3.8.5, 3.11.5 and 3.14 of Chapter 3.
Draft form — Rajasthan Stormwater Design Manual, Draft v1.0. One form for each point of comparison (POC). Flows in m³/s, volumes in m³.
A. Point of comparison (Clause 3.14.2)
Table 3F.10 — Form 3-2: point of comparison
| Field | Entry |
|---|---|
| A1. POC identifier and location | |
| A2. Area draining to the POC: site (ha) and off-site run-on (ha) | |
| A3. Off-site run-on passes through site storage? (Clause 3.14.2(c)) | |
| A4. Catchment class: standard (Clause 2.11.2) or flood-sensitive (Clause 2.11.3) | |
| A5. Tailwater applied, including joint cases of Clause 2.12 (Clause 3.14.9(c)) | |
| A6. Flood-sensitive only: largest 10% AEP pre-development peak over all durations, the cap of Clause 2.11.3 (Clause 3.14.7) | |
| A7. Flood-sensitive only: 50% AEP pre-development peak at the pre-development critical duration (Clause 2.11.3) |
B. Peak flows (Clauses 3.14.7–3.14.10)
Limit: standard catchments 0.9 × Q_pre for the same AEP and duration (Clause 3.14.10(a)); flood-sensitive catchments the caps A6 (for 1% AEP) and A7 (for 50% AEP) (Clause 3.14.10(b)).
Table 3F.11 — Form 3-2: peak flows by AEP and duration
| AEP | Duration (h) | AMC | Q_pre | Q_post, uncontrolled | Q_post, routed | Limit | Met? |
|---|---|---|---|---|---|---|---|
| 50% (2-yr) | 1 | II | |||||
| 50% (2-yr) | 2 | II | |||||
| 50% (2-yr) | 3 | II | |||||
| 50% (2-yr) | 6 | II | |||||
| 50% (2-yr) | 12 | III | |||||
| 50% (2-yr) | 24 | III | |||||
| 50% (2-yr) | 48 | III | |||||
| 50% (2-yr) | 72 | III | |||||
| 10% (10-yr) | 1 | II | |||||
| 10% (10-yr) | 2 | II | |||||
| 10% (10-yr) | 3 | II | |||||
| 10% (10-yr) | 6 | II | |||||
| 10% (10-yr) | 12 | III | |||||
| 10% (10-yr) | 24 | III | |||||
| 10% (10-yr) | 48 | III | |||||
| 10% (10-yr) | 72 | III | |||||
| 1% (100-yr) | 1 | II | |||||
| 1% (100-yr) | 2 | II | |||||
| 1% (100-yr) | 3 | II | |||||
| 1% (100-yr) | 6 | II | |||||
| 1% (100-yr) | 12 | III | |||||
| 1% (100-yr) | 24 | III | |||||
| 1% (100-yr) | 48 | III | |||||
| 1% (100-yr) | 72 | III |
C. Volumes and storage (Clauses 3.14.8–3.14.10)
Table 3F.12 — Form 3-2: volumes and storage
| AEP | Governing duration (h) | Runoff volume, pre | Runoff volume, post uncontrolled | Retention volume | Detention storage required | Peak water level in storage (m) |
|---|---|---|---|---|---|---|
| 50% (2-yr) | ||||||
| 10% (10-yr) | ||||||
| 1% (100-yr) |
C1. Governing duration for storage, and the 24, 48 and 72 h results (Clause 3.14.10): ______
D. Sensitivity runs (Clauses 3.8.5, 3.14.11)
Table 3F.13 — Form 3-2: sensitivity runs
| Run | Governing storm (AEP, duration) | Change in Q_post, routed (%) | Change in required storage (%) | Retention volume or WQv governing (Clause 3.8.5(c)) |
|---|---|---|---|---|
| Ia = 0.05S | ||||
| Standard peak rate factor (only where a lower factor is used) | — |
E. Associated checks (Clause 3.14.12)
Table 3F.14 — Form 3-2: associated checks
| Check | Result | Reference in submittal |
|---|---|---|
| Drawdown times (Chapter 4) | ||
| Minimum orifice and trash screen (Chapter 4) | ||
| Emergency spillway (Chapter 4) | ||
| Outfall-closed storage check (Chapter 5) | ||
| Downstream analysis (Chapter 5) |
F. Statement by the responsible engineer
I state that this comparison has been made by the procedure of Clause 3.14, with the same design storms in the pre- and post-development runs, and that no runoff has been diverted from one natural catchment to another to meet the criterion (Clause 3.14.2(b)).
Table 3F.15 — Form 3-2: statement by the responsible engineer
| Field | Entry |
|---|---|
| Name | |
| Qualification and registration number | |
| Signature | |
| Date |
Draft form — Rajasthan Stormwater Design Manual, Draft v1.0.