Draft v1.0 prepared by NEER. Not adopted by the Government of NCT of Delhi, DDA or any local body, and has no legal force. About this draft

Annexes to Chapter 2Design Rainfall and Design Storms

These annexes support Chapter 2. Annexes 2A to 2E will hold the statewide rainfall tables that Chapter 2 refers to: the benchmark checks and zone map, sub-daily ratios, grid-to-point factors, temporal patterns and retention depths. Each needs analysis of NIH-DHAARA and IMD records that has not yet been done for this Manual, so each is marked "To be prepared" and gives its intended layout and the rule to use until it is published (Clause 1.11.5). Form 2-1 is a draft form for the Design Rainfall Sheet that every hydrologic submittal must include (Clause 2.13). The Manual is a draft; it is not adopted by any government or agency.


Annex 2A — NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map

Supports Clauses 2.3.1 to 2.3.5 of Chapter 2.

To be prepared. This annex will compare, at benchmark points across the State, the NIH-DHAARA design depths with frequency analyses of long IMD daily station records and of IMD gridded daily data (converted to point values with Annex 2C), for 24 hours and longer and for the AEPs of Table 2.1. It will also contain the map of rainfall zones used by Annexes 2B, 2C and 2E and by the Tier B tables of Chapter 4. It needs NIH-DHAARA values at the benchmark coordinates (NIH), IMD daily and recording-gauge station records and IMD gridded rainfall (IMD), State rain-gauge records (the IMD automatic weather stations and rain gauges in the NCT, and any rain gauges of I&FC and PWD [TBC]), and district and basin boundaries (Survey of India, I&FC). Until it is published, design depths are taken from NIH-DHAARA under Clause 2.3.1, the cross-checks of Clause 2.3.3 are reported on Form 2-1, and the zone of a site is the one agreed with the Authority and recorded on Form 2-1.

Table 2A.1 — Benchmark comparison of design depths (layout)

Benchmark point IMD station ID Latitude, longitude Years of record Duration (h) AEP NIH-DHAARA (mm) IMD station analysis (mm) IMD gridded, point value (mm) NIH-DHAARA / IMD station Remarks
        24            
        48            
        72            

2A.1 The zone names below are the working names used in the Tier B table template of Chapter 4 (Clause 4.14.2). Their boundaries, and whether further zones are needed, are to be set by the analysis of this annex.

Table 2A.2 — Rainfall zones (layout)

Zone (working name) Extent (districts, basins) Representative stations Notes
DL-Z1 NCT of Delhi The whole National Capital Territory (about 1,483 km²), in the single CWC subzone 1(e). One design-rainfall zone: the NCT lies between the same isopluvials of the 1(e) report, the NIH-DHAARA cells differ by no more than about 14% at 24 hours, and the 24-hour records of Safdarjung (266.2 mm, 21 Jul 1958) and Palam (265.8 mm, 9 Jul 1972) are nearly equal (IMD; CWC; NIH-DHAARA). The four sub-areas below differ in ground, groundwater and outfall, not in design rainfall Safdarjung 42182 (daily record from 1901) and Palam 42181 (from 1959), the reference stations of Clause 2.3.6(a); Lodi Road, Ridge and Ayanagar (IMD observatories); automatic weather stations at Pragati Maidan, Mayur Vihar, Pusa, Pitampura, Delhi University, Tughlakabad, Mehrauli, Narayana and Jharoda Kalan (logging intervals and data access not stated [TBC]) Annual about 495–732 mm by district, JJAS about 83% of it (IMD, 2020). FER 1(e) 50-yr 24-h about 220–240 mm and 100-yr about 240–280 mm (Plates 9 and 10, no label near Delhi; 240 and 280 mm used, Clause 2.3.6(b)); 1-h ratio 0.34. IIT Delhi 15-minute intensities: Safdarjung 87.2 (2-yr) and 112.2 mm/h (5-yr), Palam 79.5 and 95.8 mm/h, Palam 10–23% below Safdarjung at every return period. Single events are very patchy: 5 mm at Jharoda Kalan and 228.1 mm at Safdarjung on 28 Jun 2024 (IMD, 2024). Short falls: 148.5 mm in 3 h at Safdarjung (28 Jun 2024) and 112.5 mm in 1 h at Pragati Maidan (31 Jul 2024) (as reported); 41 mm in 15 minutes at Safdarjung (1999) (IIT Delhi, 2018)
DL-Z1 NCT of Delhi: Ridge The Northern, Central, South-Central and Southern Ridge, the Chhatarpur–Mehrauli upland and Asola–Bhatti; boundary [TBC] Safdarjung; Ridge observatory Delhi quartzite at or near the surface, thin soils; water table more than 65 m below ground under the quartzite of the Central, New Delhi and South districts (CGWB, as reported). Ridge nalas run steeply to the Barapullah and Najafgarh basins; the Ridge is about 10% of the Barapullah basin (IIT Delhi, 2018). JJAS 2025 at the Ridge 982.0 mm, 75% above normal (IMD, 2025). Recharge only where fractured rock or alluvial pockets are proven by test
DL-Z1 NCT of Delhi: Yamuna floodplain and Trans-Yamuna The active floodplain (khadar) between the embankments, and the East, North-East and Shahdara districts behind the Shahdara and Left Marginal bunds; boundary [TBC] Safdarjung; Mayur Vihar Newer alluvium (sand and silt); water table within 2 m of the surface in places (CGWB, as reported). Trans-Yamuna basin about 197 km²: only the Relief Drain outfalls to the river, the rest is reversed and pumped (IIT Delhi, 2018). Yamuna at the Old Railway Bridge: danger level 205.33 m, peak 208.66 m on 13 Jul 2023 (as reported). North-East district has the lowest annual mean, about 495 mm (IMD, 2020)
DL-Z1 NCT of Delhi: central and New Delhi The NDMC area and the Central, New Delhi and South-East districts drained by the Barapullah, Kushak and Sunehri Bagh drains and the drains to the Yamuna near ITO; boundary [TBC] Safdarjung; Lodi Road Older alluvium with kankar over quartzite; deep water table in New Delhi and the south (CGWB, as reported). New Delhi district has the highest annual mean, about 732 mm (IMD, 2020). Barapullah basin about 376 km² (IIT Delhi, 2018). River-front regulators such as that of drain No. 12 (failed 13 Jul 2023); basements and underpasses
DL-Z1 NCT of Delhi: Najafgarh basin The basin of the Najafgarh drain (the Sahibi) and the Supplementary drain in the west, north-west and south-west, from Dhansa through the Kakraula regulator to the outfall below Wazirabad barrage; about 918–977 km² within the NCT (PWD, as reported; IIT Delhi, 2018); boundary [TBC] Palam; Ayanagar; Jharoda Kalan Older alluvium; the Najafgarh jheel depression (clays, not described in any source read [TBC]); water table within 2 m in parts of the North-West and West districts (CGWB, as reported). The Sahibi brings runoff from Haryana and Rajasthan (Sahibi and Banganga about 19,381 km² in the 1(e) report), above the 2,500 km² limit of the report's unit hydrograph. Waterlogging at Kirari, Nangloi and Mundka (as reported)

Annex 2B — Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule

Supports Clauses 2.6.1 to 2.6.4 of Chapter 2.

To be prepared. This annex will tabulate, for each zone of Annex 2A, the ratios of the t-hour to the 24-hour design depth from NIH-DHAARA, which are derived from hourly records, against the ratios implied by IMD Das et al. (2022) and by the one-third rule. It needs NIH-DHAARA depths for each duration at representative points in each zone (NIH), IMD recording-gauge data and the IDF values of Das et al. (2022) (IMD). Until it is published, sub-daily depths are read directly from NIH-DHAARA or an approved station IDF (Clause 2.6.1). Where only daily depths are available, the ratios used are those agreed with the Authority, which in Delhi are those of Clause 2.3.6: the CWC Flood Estimation Report ratios for subzone 1(e) in Table 2B.1, the IIT Delhi station values below 1 hour, and the 1- and 3-hour floors of Clause 2.3.6(g) (Clause 2.6.2), and are recorded on Form 2-1. The one-third rule is not used (Clause 2.6.4).

2B.1 The first row of Table 2B.1 gives the ratios of the one-third rule P(t) = P(24)·(t/24)^(1/3), for comparison only. The 1, 3, 6 and 12 h values are those stated in the commentary to Clause 2.6; the 2 h value is computed from the same formula. The rule shall not be used for design unless this annex confirms it for the zone concerned (Clause 2.6.4).

Table 2B.1 — Ratios P(t)/P(24h) by zone (layout)

Zone Source 1 h 2 h 3 h 6 h 12 h 24 h
All (reference only, not for design) One-third rule 0.35 0.44 0.50 0.63 0.79 1.00
DL-Z1 NCT of Delhi (all sub-areas) CWC FER 1(e), 50-yr (interim design ratios, Clause 2.3.6(e)) 0.340 0.475 0.560 0.680 0.840 1.00
DL-Z1 NCT of Delhi (all sub-areas) Floors of Clause 2.3.6(g) at 50-yr, as ratios to the 240 mm of Clause 2.3.6(b) (comparison only; the floors are depths) 0.44   0.63     1.00
DL-Z1 NCT of Delhi (all sub-areas) NIH-DHAARA, 50-yr, Safdarjung cell (comparison only; 3- and 6-hour values not queried) 0.26 0.41     0.84 1.00

2B.2 Depths from fixed observation windows are converted to true-interval depths with the factors of Clause 2.6.3, repeated in Table 2B.2. They are the standard WMO (Hershfield) values and are not provisional.

Table 2B.2 — Fixed-interval adjustment factors (Clause 2.6.3)

Number of fixed observation intervals in the duration Factor
1 1.13
2 1.04
3–4 1.02

Annex 2C — Grid-to-point factors

Supports Clauses 2.7.1 and 2.7.4 of Chapter 2.

To be prepared. This annex will give the factors that convert grid-average design depths (for example from 0.25° cells) to point depths, by zone, duration and AEP. It needs paired frequency analyses of IMD gridded rainfall and of the IMD and State gauges inside each cell (IMD, I&FC), the benchmark points of Annex 2A, and a stated method for deriving the factors. Until it is published, design depths are taken as point values from NIH-DHAARA or an approved station IDF (Clauses 2.3.1 and 2.3.2). Grid-average values are not used as design depths unless a conversion agreed with the Authority is recorded on Form 2-1 (Clause 1.11.5).

2C.1 The commentary to Clause 2.7 shows why the factors matter, and in Delhi the reanalysis cells err low. At Safdarjung the IMDAA cell of NIH-DHAARA (about 12 km) gives a 50-year 24-hour depth of about 204 mm and a 100-year depth of about 229 mm, while the gauge recorded 228.1 mm on 28 June 2024 and 266.2 mm on 21 July 1958; at Palam the cell's 500-year value, about 268 mm, is about the gauge's record of 265.8 mm (9 July 1972). The cell's 50-year 1-hour depth, about 54 mm, is about half the 112.5 mm reported in one hour at Pragati Maidan on 31 July 2024 (NIH-DHAARA, queried 6 Nov 2026; IMD; as reported). Values of this kind are grid-average values and need these factors before any use as point depths; under Clause 2.3.6 they are not used as design depths in Delhi until this annex and Annex 2A are published.

Table 2C.1 — Grid-to-point factors (layout)

Zone Grid product and cell size Duration (h) AEP Factor (point / grid) Stations used Years of record
    24        
    48        
    72        

Annex 2D — Delhi temporal patterns (Huff curves)

Supports Clauses 2.9.3 and 2.9.4 of Chapter 2, and Clause 11.7.3 of Chapter 11.

To be prepared. This annex will give dimensionless time-distribution (mass) curves of Delhi storms, in the form introduced by Huff (1967), by zone, storm-duration class and quartile, at stated probability levels. It needs storm hyetographs from recording gauges and automatic weather stations (IMD, the IMD automatic weather station network in the NCT, and any recording gauges of I&FC and PWD [TBC]), separated into independent storms by a stated rule, and the Safdarjung storm of 21 July 1958, the Palam storm of 9 July 1972, the storm of 8–9 July 2023, the storms of 28 June and 31 July 2024, and the heavy-rain days of the 2021 monsoon among them. Until it is published, design storms use the alternating-block pattern of Clause 2.9.1 and the 48- and 72-hour pattern of Clause 2.9.2; for catchments of 25–5,000 km², the CWC Flood Estimation Report curves may be used with a sensitivity run under Clause 2.9.1 (Clause 2.9.4). SCS Type distributions are not used (Clause 2.9.3). For the disaggregation of daily records in continuous simulation (Clause 11.7.3), the method is agreed with the Authority and recorded (Clause 1.11.5).

Table 2D.1 — Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)

Fraction of storm time 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
10% probability curve 0                   1.0
50% probability curve 0                   1.0
90% probability curve 0                   1.0

2D.1 Each table shall state the zone, the duration class, the quartile (the quarter of the storm in which most rain fell), the number of storms analysed and the period of record.

Reference: Huff, F.A. (1967). Time distribution of rainfall in heavy storms. Water Resources Research 3(4), 1007–1019.


Annex 2E — Retention percentile depths by zone

Supports Clauses 2.8.3 and 2.10.1 to 2.10.2 of Chapter 2, Clause 4.4 of Chapter 4 and Chapter 8.

To be prepared. This annex will give, for each zone of Annex 2A, the retention design depth P_R: the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record (Clause 2.10.1). It needs long daily records at stations in each zone (IMD, I&FC) and IMD gridded data with the factors of Annex 2C where stations are sparse. Until it is published, P_R is computed by the definition of Clause 2.10.1 from the long-term daily record of a station agreed with the Authority, by the steps in 2E.1, and recorded on Form 2-1 (Clause 1.11.5).

2E.1 Computing P_R from a daily record.

  1. Take the daily (24-hour) rainfall series of the station for its full record.
  2. Keep only the days with rain of 2.5 mm or more (wet days).
  3. Rank the wet-day depths and take the depth not exceeded on 90% of them (the 90th percentile).
  4. Do not apply the climate factor (Clause 2.8.3) or the fixed-interval factor; P_R is a statistic of everyday rainfall, not an AEP design depth.
  5. Record the station, the period of record, the number of wet days and P_R on Form 2-1.

Table 2E.1 — Retention depth P_R by zone (layout)

Zone Stations or grid cells used Period of record Number of wet days (≥ 2.5 mm) P_R, 90th percentile (mm) Issued on
DL-Z1 NCT of Delhi          

Form 2-1 — Design Rainfall Sheet

Supports Clauses 2.3 to 2.13 of Chapter 2, and Clause 10.4.1(d) of Chapter 10.

Draft form — Delhi Stormwater Design Manual, Draft v1.0. One sheet for each hydrologic submittal. The steps follow Figure 2.3 of Chapter 2.

Table 2F.1 — Form 2-1: site, source and storms

No. Item (clause) Entry
A. Site (Clause 2.13, item 1)
A1 Project and site ______
A2 Site coordinates (latitude, longitude, decimal degrees) ______
A3 Rainfall zone (Annex 2A, or as agreed with the Authority) ______
A4 Contributing catchment area (km²) (Clause 2.7) ______
A5 Design life: more than 25 years / temporary works, 5 years or less (Clause 2.8.2) ______
A6 Outfall under tidal or river backwater influence: Yes / No (Clauses 2.5.3, 2.12) ______
B. Source (Clauses 2.3, 2.3.5; item 2)
B1 NIH-DHAARA: version or access date ______
B2 Coordinates queried ______
B3 Screenshot or export of the values extracted attached: reference ______
B4 Station IDF used (Clause 2.3.2): No / Yes — station, ID, distance from site (km) ______
B5 Station IDF: years of recording-gauge data (30 or more); published or approved by ______
B6 Station IDF: change of terrain or coastal exposure between gauge and site: None / describe ______
C. AEPs and durations (Clauses 2.4, 2.5)
C1 Elements designed and their AEPs (Table 2.1) ______
C2 Conveyance: Tc and design duration (not less than 10 min) (Clause 2.5.1) ______
C3 Storage: durations checked from {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48 and 72 h included (Clause 2.5.2) ______
C4 Critical duration found for each storage element ______
D. Conversions
D1 Sub-daily depths: read directly / from Annex 2B ratios / from ratios agreed with the Authority (Clauses 2.6.1, 2.6.2) ______
D2 Fixed-interval factor applied: none (true-interval source) / 1.13 / 1.04 / 1.02 (Clause 2.6.3) ______
D3 Grid-to-point factor: not needed (point source) / Annex 2C / agreed value (Clause 2.7.1) ______
D4 ARF: 1.0 (10 km² or less; single-site storage) / CWC curve / interpolated (Clauses 2.7.2–2.7.4) ______
D5 Climate factor: 1.20 (≤ 6 h) and 1.10 (> 6–72 h) / 1.0 temporary works / projected depths under Clause 2.8.4 ______
E. Cross-checks (Clause 2.3.3; item 4)
E1 IMD Das et al. (2022) values for 1–24 h: reported in Table 2F.2 ______
E2 CWC subzone 1(e) 24-hour point value, catchments of 25–5,000 km²: subzone used ______
E3 CWC floor governs for any AEP: No / Yes — AEPs ______
F. Retention depth (Clause 2.10)
F1 P_R (mm) and source: Annex 2E zone value / computed under Annex 2E, 2E.1 — station and period ______
F2 No climate factor applied to P_R (Clause 2.8.3): confirmed ______
G. Design storms (Clauses 2.9, 2.11, 2.12; items 5 and 6)
G1 Storms up to 24 h: alternating block, peak at 50%; time step (≤ Tc/3 and ≤ 15 min) ______
G2 48 and 72 h storms: built under Clause 2.9.2 (Table 2F.3) ______
G3 Other pattern used: none / Annex 2D / CWC FER with sensitivity run (Clauses 2.9.3, 2.9.4) ______
G4 Hyetographs attached as a table and a plot for each design storm: reference ______
G5 AMC: III for every design storm of July–September, whatever its duration, in every sub-area of DL-Z1; II for storms in other months (Clause 2.11.4) ______
G6 Pre-development condition: greenfield, open land in good condition for the mapped HSG (Clause 2.11.5) ______
G7 Release criterion: standard, Q_post ≤ 0.9 × Q_pre (Clause 2.11.2) / flood-sensitive, mixed-frequency rule (Clause 2.11.3) ______
G8 Tailwater joint cases run (Clause 2.12): case (a) MHWS + sea-level allowance; case (b) 10% AEP 48 h storm with 1% AEP still-water level + sea-level allowance; governing case ______
H. Prepared by
H1 I confirm that the values above are those extracted and used in the submittal. Name, registration number, signature, date ______

Design depth = source depth × fixed-interval factor × grid-to-point factor × ARF × climate factor. Where the design depth is lower than the CWC floor for the same AEP, the floor is adopted (Clause 2.3.3).

Table 2F.2 — Form 2-1: depth table (Clause 2.13, item 3)

AEP (T-yr) Duration Source depth (mm) Fixed-interval factor Grid-to-point factor ARF Climate factor Design depth (mm) IMD Das et al. (2022) (mm) CWC floor (mm) Adopted depth (mm)
                     
                     
                     
                     

Table 2F.3 — Form 2-1: 48- and 72-hour storm construction (Clause 2.9.2)

AEP (T-yr) Duration (h) Total design depth (mm) 24 h design depth, final 24 h (mm) Remainder (mm) Hours before the final 24 h Uniform intensity before the final 24 h (mm/h)
  48       24  
  72       48