Draft v1.0 prepared by NEER. Not adopted by the Government of NCT of Delhi, DDA or any local body, and has no legal force. About this draft

Chapter 2Design Rainfall and Design Storms


2.1 Purpose and scope

2.1.1 This chapter sets the rainfall inputs for every hydrologic calculation in this Manual: drain and inlet sizing (Chapter 6), retention and detention sizing (Chapter 4), downstream and tailwater analysis (Chapter 5), and waterbody and tank works (Chapter 7).

2.1.2 It specifies:

  • (a) the approved sources of design rainfall depth and intensity;
  • (b) how depths are converted between durations, between point and area, and from present to future climate;
  • (c) how design storms (hyetographs) are constructed; and
  • (d) the storms that must be applied to pre- and post-development conditions.

2.1.3 This chapter applies throughout Delhi. Where MCD, NDMC, the Delhi Cantonment Board or DDA has adopted a stricter rainfall standard under Chapter 1, the stricter standard governs.

Commentary. Most past drainage failures in Delhi trace to the rainfall input, not the hydraulics. Delhi shows how. The 1976 drainage plan is reported to have sized drains for 25 mm/h, and no approved design storm has replaced it (as reported). The 2018 Drainage Master Plan of IIT Delhi derived 15-minute intensities at Safdarjung and Palam and used the 2- and 5-year storms, but it was never acted upon (Delhi High Court, 8 April 2024), and the PWD plan of 2025 states a capacity of 70 mm/h without a duration or return period (as reported). The two published sources that seem to fill the gap do not. The panel for Safdarjung in IMD Das et al. (2022) repeats a curve that is common to many stations and is not an analysis of Delhi's record, and NIH-DHAARA's reanalysis-based depths are low in Delhi at every duration, about half the 1-hour falls recorded in 2024 (Clause 2.3.6). The CWC ratios, the only regional sub-daily source, also understate Delhi's short storms, the opposite of their error on the coast. Fixing one transparent source and method for the whole state is the main purpose of this chapter.


2.2 Definitions

Term Meaning in this Manual
Annual exceedance probability (AEP) Probability that a given rainfall depth is equalled or exceeded in any one year. A 1% AEP storm is the "100-year" storm. Both forms are used here: T-year = 1/AEP.
IDF / DDF Intensity–duration–frequency and depth–duration–frequency relationships for a location.
Point rainfall Rainfall at a single location, as measured by a rain gauge.
Design storm A hyetograph (rainfall depth versus time) of stated AEP, duration and temporal pattern.
Critical duration The storm duration that produces the largest peak flow, water level or storage requirement for the element being designed.
Areal reduction factor (ARF) Ratio of catchment-average rainfall to point rainfall for the same AEP and duration.
SW monsoon season (JJAS) June–September, when Delhi receives about 83% of its annual rainfall: a mean of 553.8 mm in June–September out of 670.7 mm a year for 1989–2018, with August (188.7 mm) and July (172.7 mm) the wettest months (IMD, 2020). The June–September normals for 1971–2020 are 640.4 mm at Safdarjung and 598.2 mm at Palam (IMD, 2025). Annual means range from about 495 mm in North East district to 732 mm in New Delhi district (IMD, 2020). The normal date of onset over Delhi is 27 June, with the earliest on 15 June 2008 and the latest on 26 July 1987, and the normal date of withdrawal is 25 September, with the latest on 17 October 2013 (IMD, 2025). The three largest June days at Safdarjung fell in the second half of the month, 235.5 mm in 1936, 228.1 mm on 28 June 2024, the day of onset that year, and 191.6 mm on 30 June 1981 (IMD, 2024). The antecedent moisture rule of Clause 2.11.4 refers to this season; the pre-monsoon deadline of 31 May is set ahead of the earliest onset.
Storms outside the season Western disturbances in winter and thunderstorms before the monsoon bring rarer but large falls: 134.0 mm at Safdarjung and 117.8 mm at Palam on 16 April 1983, 116.8 mm at Safdarjung on 28 January 1885, and 172.7 mm at Safdarjung on 1 October 1954, after the normal withdrawal (IMD). The storm of 8–9 July 2023 came from a western disturbance meeting the monsoon (as reported). Design statistics use annual maxima from all months, and no works deadline or operating rule shall assume that heavy rain is confined to June–September.
Climate factor (CF) Multiplier applied to present-day design depths to represent the design-life climate.
Approved source A rainfall source listed in Clause 2.3.

2.3 Approved sources of design rainfall

2.3.1 Primary source. Design rainfall depths and intensities shall be taken from the National Institute of Hydrology, Roorkee NIH-DHAARA platform (Design Hydrology and Advanced Rainfall Analysis, nihdhaara.in). Use its IDF / frequency tools for the site's coordinates, for each duration and AEP required by Clause 2.4. In Delhi this clause is suspended until Annex 2A is published: Clause 2.3.6 sets the interim source.

2.3.2 Station IDF. A station-specific IDF relationship may be used in place of 2.3.1 only if all of the following hold:

  • (a) it is derived from at least 30 years of recording-gauge (hourly or finer) data;
  • (b) it has been published or approved by IMD, the State Hydrology Authority or the approving authority; and
  • (c) the gauge is within 10 km of the site, with no major change of terrain or coastal exposure in between.

Where a station IDF is used, the design value shall be the greater of the station value and the NIH-DHAARA value.

2.3.3 Cross-checks (mandatory, not alternatives). The designer shall report, but need not adopt, the following values for comparison:

  • (a) the IMD isopluvial / IDF values of Das et al. (2022), MAUSAM 73(4), for durations of 1–24 h;
  • (b) for catchments of 25–5,000 km², the 24-hour point rainfall from the CWC Flood Estimation Report for subzone 1(e) (Upper Indo-Ganga Plains), as applicable.

Where the design value is lower than the CWC 1(e) value for the same AEP, the CWC value shall be adopted as a floor.

2.3.4 Not permitted. None of the following shall be used as a design rainfall source:

  • (a) generalised all-India IDF formulae (for example Kothyari & Garde, 1992);
  • (b) rainfall values that cite no source, including vendor or web-calculator tables;
  • (c) single-event maxima; or
  • (d) design intensities carried forward from a previous project without a stated AEP.

IIT Delhi station fits + CWC FER 1(e) Interim primary source (Cl. 2.3.6) 15-min fits; 24-h plates × 1(e) ratios Approved station IDF ≥30 yr recording gauge, ≤10 km optional (Cl. 2.3.2) Take the greater per AEP and duration Safdarjung / Palam maxima 2–25 yr 24-h depths (Cl. 2.3.6(c)) 1-h and 3-h floors 10–100 yr (Cl. 2.3.6(g)) NIH-DHAARA reported for comparison only Adjustments, in order 1. Fixed-interval → true-interval (Cl. 2.6.3) 2. Grid → point, if grid values (Cl. 2.7.1) 3. Areal reduction, >10 km² only (Cl. 2.7.3) 4. Climate factor 1.20 / 1.10 (Cl. 2.8) → Design depth → hyetograph (Cl. 2.9) Delhi (Cl. 2.3.6): IIT Delhi 15-min fits below 1 h at 2–5 yr; FER 1(e) plates × ratios for longer and rarer storms; 1-h and 3-h floors at 10–100 yr.

Figure 2.1 — Design rainfall source hierarchy and adjustment sequence. Original drawing for this Manual.

2.3.5 Version control. Every submittal shall record the source, its version or access date, the coordinates queried, and the values extracted (Clause 2.13).

2.3.6 Interim source in Delhi. Until Annex 2A is published and confirms NIH-DHAARA, or an approved station IDF, for zone DL-Z1, Clause 2.3.1 does not apply in Delhi, and design rainfall shall be taken as follows:

  • (a) Reference station. The reference station is Safdarjung, IMD 42182, for a site in the Barapullah or Trans-Yamuna basin, on the Ridge, in central and New Delhi or on the Yamuna floodplain, and Palam, IMD 42181, for a site in the Najafgarh basin, as in the Drainage Master Plan prepared by IIT Delhi for I&FC (IIT Delhi, 2018). For a catchment that crosses the Ridge or the boundary between the Najafgarh basin and the other basins, the higher value of the two stations is used at every duration and AEP.

  • (b) 24-hour depth, 2% and 1% AEP (50- and 100-yr). 240 mm and 280 mm throughout the NCT, set by this Manual from Plates 9 and 10 of the CWC Flood Estimation Report for subzone 1(e), Upper Indo-Ganga Plains, which covers the whole of the NCT. The plates carry no contour label near Delhi; read by eye, the city lies in a saddle between contours that give about 220–240 mm for the 50-year and 240–280 mm for the 100-year storm, and the upper end of each range is used. Where the Gumbel estimate of (c) for the reference station is higher for the same AEP, it governs.

  • (c) 24-hour depth, 50%, 20%, 10% and 4% AEP (2-, 5-, 10- and 25-yr). The report has no plates for these. The depth is the Gumbel (EV1) estimate from the annual maximum daily rainfall series, of all months, of the reference station, multiplied by the fixed-interval factor of Clause 2.6.3. Safdarjung has a daily record from 1901 and Palam from 1959 (IMD).

  • (d) 48- and 72-hour depths. The Gumbel estimate from the annual maximum 2-day and 3-day rainfall series of the reference station, with the fixed-interval factors of Clause 2.6.3, and not less than the 24-hour depth for the same AEP.

  • (e) Durations of 1 to 24 hours. The 24-hour depth of (b) or (c) multiplied by the ratios of the 1(e) report in Table 2B.1, at every AEP: 0.34 at 1 hour, 0.475 at 2 hours, 0.56 at 3 hours, 0.607 at 4 hours, 0.647 at 5 hours, 0.68 at 6 hours, 0.77 at 9 hours, 0.84 at 12 hours and 0.93 at 18 hours. Between the tabulated durations the ratio is interpolated on logarithmic axes. The 1- and 3-hour depths are then subject to (g).

  • (f) Durations below 1 hour. At 50% and 20% AEP (2- and 5-yr), the 15-minute intensity is that of the IIT Delhi station fits: 87.2 and 112.2 mm/h at Safdarjung (21.8 and 28.1 mm in 15 minutes) and 79.5 and 95.8 mm/h at Palam (19.9 and 24.0 mm). Between 15 minutes and 1 hour the depth is interpolated on logarithmic axes between the 15-minute depth and the 1-hour depth of (e), and the same line is extended to 10 minutes. At 10% AEP and rarer (10- to 100-yr), the depth for a duration below 1 hour is the 1-hour design depth for that AEP, after (g), multiplied by the ratio of the depth for that duration to the 1-hour depth on the 5-year curve of the reference station. These rules are set by this Manual.

  • (g) Floor for short storms, 10-yr and rarer. The 1-hour and 3-hour depths shall be not less than the following values, set by this Manual, at every reference station; the 2-hour depth shall be not less than the value interpolated on logarithmic axes between the 1- and 3-hour values for the same AEP:

    AEP (T-yr) 10% (10) 4% (25) 2% (50) 1% (100)
    1-hour depth not less than (mm) 80 95 105 115
    3-hour depth not less than (mm) 115 135 150 165

    The reason is that the ratios of the 1(e) report, derived in 1984 from 5–38 years of recording-gauge data across the subzone, understate Delhi's short storms. With the depths of (b) they give about 82 mm in 1 hour and 134 mm in 3 hours for the 50-year storm. Both values have since been exceeded: Safdarjung recorded 148.5 mm in 3 hours between 02:30 and 05:30 on 28 June 2024, and on 31 July 2024 the Pragati Maidan automatic weather station recorded 112.5 mm in 1 hour and Mayur Vihar 89.5 mm (as reported). The floors start from those two falls. The Safdarjung fall is the largest 3-hour fall known at a gauge with some five decades of recording-gauge record; the largest of n years of record is, on average, about a (n+1)-year event, so the 50-year 3-hour depth is set at not less than 150 mm. The Pragati Maidan fall is the largest 1-hour fall known in a network of a dozen or more stations that have recorded for more than a decade, well over a hundred station-years [TBC], so the 100-year 1-hour depth is set at not less than 115 mm. The other AEPs are scaled from these two values in the proportions of the IIT Delhi 15-minute fit at Safdarjung, whose 10-, 25-, 50- and 100-year intensities stand as 0.71 : 0.83 : 0.91 : 1, and rounded to 5 mm. The floors are present-day, true-interval values: the fixed-interval factor of Clause 2.6.3 is not applied to them, and the climate factor of Clause 2.8 is. They are interim: the two falls are known from press reports, IMD's hourly data for them have not been read [TBC], and Annex 2B is to replace the floors with a frequency analysis of the IMD recording-gauge and automatic weather station records of Delhi.

  • (h) Order of depths. For the same AEP, no depth shall be less than the depth for a shorter duration.

  • (i) NIH-DHAARA. Its present-day values at the site are reported on Form 2-1 beside the interim values, for comparison only. Its projected depths are not used under Clause 2.8.4; the ratio of its projected to its present-day depths may be reported as a check on the climate factors of Table 2.2, which apply.

  • (j) IMD Das et al. (2022). The panel for Safdarjung in that paper repeats a curve that is common to many stations and is not an analysis of the Safdarjung record. It is recorded on Form 2-1 as not applicable and is not used as a value, a check or a floor.

  • (k) Station IDF. The IIT Delhi fits do not meet Clause 2.3.2: they rest on fewer than 30 years of record (1979–2008 at Safdarjung, with five years missing, and 1977–2008 at Palam) and have not been approved; they are used only as (f) sets out. An IDF for Safdarjung or Palam that meets Clause 2.3.2 and is published in Annex 2B replaces (e) to (g) for the durations and AEPs it covers.

  • (l) Other clauses. Where Clauses 2.3.2, 2.6.1, 2.7.1 and 2.13, Annexes 2A to 2C and Form 2-1 refer to the NIH-DHAARA value, the value under this clause is meant.

Commentary. NIH-DHAARA is a national, publicly accessible product from a Government of India institution, and it can be queried at any point in the State. That makes it a reproducible default that an approving authority can check. NIH-DHAARA's sub-daily values are derived from hourly records, not disaggregated from daily totals. That makes it the only public source suitable for sizing drains, which depend on short-duration intensity. Its values should still be checked against the long IMD daily record at 24 hours and longer (Annex 2A). In Delhi the platform does not yet meet that purpose. Its present-day values there come from IMDAA reanalysis (about 12 km), not from gauges, and they are low at every duration. Its 50-year 24-hour depths are 189–215 mm in the six cells queried (204 mm at Safdarjung, 189 mm at Palam), below the 220–240 mm of the CWC plates; Safdarjung's fall of 228.1 mm on 28 June 2024 is about its 100-year value, and Palam's record of 265.8 mm (9 July 1972) about its 500-year value. Its 50-year 1-hour depths, 52–64 mm, are about half the 112.5 mm that fell in one hour at Pragati Maidan in July 2024, and its ERA5 option gives 21 mm (NIH-DHAARA, queried 6 Nov 2026; IMD). A source that errs low by these margins cannot be adopted, so Clause 2.3.6 uses the CWC report, the long IMD station records and the IIT Delhi station fits until Annex 2A has been done, and uses NIH-DHAARA for comparison and as a check on the climate factors only. Delhi differs from the coastal States in one respect. There the CWC sub-daily ratios give 1-hour depths above every hourly fall in the old recording-gauge records; in Delhi they give less than falls recorded in 2024, which is why Clause 2.3.6(g) sets floors at 1 and 3 hours. The interim rules for the more frequent AEPs, the 48- and 72-hour depths, durations below 1 hour, the single values of (b) and the floors of (g) are set by this Manual. Several points are unresolved. The plate values were read by eye on a scan with no contour label near Delhi, and the report's design-office number is not on the scanned pages [TBC]. The IIT Delhi fits rest on 15-minute annual maxima to 2008; the 30-, 45- and 60-minute intensities are shown only on a chart; and the Safdarjung fit carries a slip, a scale parameter of 22.071 where the printed maxima give 22.62, which changes the 2- and 5-year intensities by less than 1% [TBC]. The 2025 drainage master plan of PWD is reported to raise drain capacity from 25 mm/h, the basis of the 1976 plan, to 70 mm/h, but neither the duration nor the return period of that figure has been published (as reported). IMD's records date Safdarjung's June record of 235.5 mm to 28 June 1936 in Extremes and to 24 June 1936 in its press release of 28 June 2024 [TBC].


2.4 Design return periods (summary)

2.4.1 Design AEPs are set in the chapters for each element. They are summarised here so that the correct rainfall is extracted at the start of design.

Table 2.1 — Design return periods (summary)

Element Design AEP (return period) Check event Chapter
Minor drains: Old Delhi and New Delhi core and high-density areas 10% (10-yr) 1% (100-yr) overland path 6
Minor drains: other Class I urban areas 20% (5-yr) 1% overland path 6
Minor drains: other areas 50% (2-yr) 1% overland path 6
Arterial roads and crossings 2–4% (25–50-yr) next higher AEP 6
Collector / local roads 4% / 10% (25 / 10-yr) 2% / 4% (50 / 25-yr), plus the 1% overland path 6
Major (overland) system 1% (100-yr) — 6
Retention volume Percentile daily rainfall (Clause 2.10) — 4
Detention: standard catchments 50%, 10%, 1% (2, 10, 100-yr) 1% emergency spillway 4
Detention: flood-sensitive catchments Mixed-frequency rule, Clause 2.11 1% 4
Building floor levels 1% + 0.5 m freeboard — 6
Detention emergency spillway 1% with outlet blocked 0.2% (500-yr) where high hazard 4

Commentary. These values exceed the CPHEEO (2019) national advisory minimums of 5-yr (Class I cities) and 2-yr (other areas). CPHEEO allows a State to set higher values. The values are set in Chapters 4 and 6, and the table is reproduced here for convenience.


2.5 Design durations

2.5.1 Conveyance elements (pipes, open drains, inlets, culverts) shall be designed with the intensity for a duration equal to the time of concentration (Tc) of the contributing area (Chapter 3). The minimum duration is 10 minutes.

2.5.2 Storage elements (detention, retention, tanks, pumped sumps) shall be checked for every duration in the set {1, 2, 3, 6, 12, 24, 48, 72 h}. The largest required storage or water level governs. The 24-, 48- and 72-hour storms are mandatory checks at every site, whatever the critical-duration result.

2.5.3 Tidally influenced outfalls. For storage draining to a tidally influenced outfall (Chapter 5), the 48- and 72-hour storms shall also be run with the tailwater boundary of Clause 2.12.

Commentary. Delhi's worst floods have come when a long wet spell, in Delhi or in the hills above it, meets a full river. In July 2023, 153 mm fell at Safdarjung in the 24 hours to 08:30 on 9 July, the highest July day since 1982, and releases from Hathnikund were reported at up to 3.59 lakh cusecs (about 10,200 m³/s); the river then rose for four more days to its record of 208.66 m on 13 July, and the drains that outfall to it were held shut (as reported). In the 2021 monsoon Delhi received about 1,159–1,176 mm, the most since 1964, with about 380–404 mm in the first half of September alone (as reported). July and August hold the monthly records, 632.2 mm at Safdarjung in July 2003 and 605.1 mm at Palam in July 1977 (IMD), and in 2025 the June–September rainfall was 902.6 mm at Safdarjung and 982.0 mm on the Ridge, 41% and 75% above normal, while the Yamuna crossed the danger level on 2 September (IMD, 2025; as reported). In the Trans-Yamuna basin, where the drains are pumped, storage behind a closed outfall is filled by the whole wet spell, not by its peak hour. A rule based only on critical duration, applied to a small site, picks a 1–2 hour storm and misses this failure mode. That is why the long-duration checks are mandatory.


2.6 Sub-daily rainfall

2.6.1 Where NIH-DHAARA or an approved station IDF provides values directly for the required duration, those values shall be used.

2.6.2 Where only daily (24-hour) depths are available for a duration below 24 hours, the sub-daily depth shall be derived using the ratio set of Annex 2B. These are duration-to-24-hour ratios calibrated to Delhi recording gauges. They shall not be lower than the ratios of the CWC Flood Estimation Report for subzone 1(e). The IMD Das et al. (2022) Safdarjung panel repeats a generic curve and is not used as a floor in Delhi.

2.6.3 Fixed-interval adjustment. Depths from fixed observation windows (for example 08:30–08:30 IST daily data, or clock-hour data) shall be converted to sliding-window ("true interval") depths:

  • 1.13 for a single fixed observation interval;
  • 1.04 for 2 intervals;
  • 1.02 for 3–4 intervals.

This adjustment does not apply where the approved source already gives true-interval values.

2.6.4 The empirical relationship P(t) = P(24)·(t/24)^(1/3) shall not be used for design unless Annex 2B confirms it for the zone concerned.

Commentary. The one-third power rule is common in Indian project reports, but no primary IMD source for it was found during research for this Manual. It applies one fixed curve shape everywhere: P(1h)/P(24h) = 0.35, P(3h) = 0.50, P(6h) = 0.63 and P(12h) = 0.79. It cannot represent the difference between a short convective burst and a long SW monsoon soak, and it tends to understate short-duration depths in convective coastal storms. Annex 2B shall tabulate the NIH-DHAARA ratios P(t)/P(24h) against these values by zone. That comparison shows whether the rule is acceptable anywhere in the State and corrects older daily-based analyses. The fixed-interval factors are the standard WMO (Hershfield) values. The IMD 2022 study applies similar clock-hour to any-hour corrections.


2.7 Point, grid and areal rainfall

2.7.1 Design depths are point values. Where an approved source provides grid-average values (for example 0.25° cells), they shall be converted to point values with the grid-to-point factors in Annex 2C before use.

2.7.2 For catchments ≤ 10 km², ARF = 1.0.

2.7.3 For catchments > 10 km², apply ARF as follows:

  • for 25–5,000 km² in subzone 1(e): use the ARF curves of the applicable CWC Flood Estimation Report;
  • for 10–25 km²: interpolate linearly between ARF = 1.0 at 10 km² and the CWC value at 25 km².

2.7.4 An ARF shall never be applied to storage design for a single development site.

Commentary. Gridded and district-average return levels are much lower than point values. For example, Safdarjung recorded 228.1 mm in the 24 hours to 08:30 on 28 June 2024, about the 100-year 24-hour depth of 229 mm that NIH-DHAARA's IMDAA cell gives there, and Palam's record of 265.8 mm (9 July 1972) is about the cell's 500-year value (NIH-DHAARA, queried 6 Nov 2026; IMD). On the same morning the gauges of the city ranged from 5 mm at Jharoda Kalan to 228.1 mm at Safdarjung (IMD, 2024), which no cell of about 12 km can show. Neither error can be corrected without the factors of Annex 2C. Using grid values as point values without correction would make site-level design unsafe.


2.8 Climate factor

2.8.1 Until a statewide future-climate rainfall product is adopted, present-day design depths shall be multiplied by the following interim climate factors:

Table 2.2 — Interim climate factors

Duration Climate factor (CF)
≤ 6 h 1.20
> 6 h to 72 h 1.10

2.8.2 The CF applies to all elements with a design life of more than 25 years. For temporary works (design life ≤ 5 years), CF = 1.0.

2.8.3 The climate factor does not apply to the retention depth (Clause 2.10) or to the water quality volume depth (Chapter 8). Those depths are percentile or frequent-event statistics of everyday rainfall, not AEP design values.

2.8.4 Where NIH-DHAARA, or a product adopted on review under Clause 2.14, provides projected future-climate depths, those depths shall replace the interim factors.

Commentary. CPHEEO (2019) considers a fixed climate factor "not feasible" nationally and recommends trend testing instead. That leaves designers without a usable number. The 1.20 short-duration factor matches the UK value cited by CPHEEO itself. It is at or below published projections for India: Ali and Mishra (2018) project 3-hourly 100-year maxima rising by about 20% at 1.5 °C and 25% at 2.0 °C of warming. No Delhi design uplift factor has been adopted. The PWD drainage master plan of 2025 is reported to allow 11% for the rise in rainfall intensity (as reported); that is below the factor of Table 2.2 for durations up to 6 hours, and this Manual states the difference rather than adopting it. IMD's monograph for Delhi found no significant trend in monthly, seasonal or annual rainfall for 1989–2018, and "no significant increase or decrease in Heavy rainfall days" at any station (IMD, 2020), but those records end before the falls of 2021, 2023 and 2024, and the station IDF of 2018 rests on data to 2008. Studies of short-duration rainfall point to rises of the order of Table 2.2: one finds 1-hour intensities at Safdarjung about 27–33% higher with a GEV fit than with classical methods (Chaudhuri and Sharma, 2020), and another a rise of about 38.7% in 5-year short-duration extremes at New Delhi under non-stationary analysis (Vinod and Mahesha, 2024); both were read in summary only. Delhi's climate change action plan projects an increase in heavy rainfall but gives no percentage that was found (as reported). NIH-DHAARA offers a CMIP6 projection for Delhi but no historical run of the same model, so no ratio of future to present depths can be formed; under Clause 2.3.6(i) it would serve only as a check. The factors of Table 2.2 are therefore interim values, not Delhi estimates.


2.9 Temporal patterns (design hyetographs)

2.9.1 Storms up to 24 hours. Use the nested alternating-block method:

  • construct the storm from the same IDF relationship (after the climate factor), at time steps no longer than Tc/3 and no longer than 15 minutes;
  • place the peak block at 50% of the storm duration.

2.9.2 48- and 72-hour storms (SW monsoon pattern). Construct as follows:

  • (a) The total storm depth equals the design depth for the full duration (48 or 72 h).
  • (b) The final 24 hours contain the 24-hour design depth for the same AEP, distributed by the alternating-block method of 2.9.1.
  • (c) The remaining depth (total minus the 24-hour depth) is spread uniformly over the preceding 24 or 48 hours.

2026-10-31T09:49:37.193022 image/svg+xml Matplotlib v3.9.4, https://matplotlib.org/ 0 6 12 18 24 Time (h) 0 10 20 30 40 50 60 70 80 Rainfall (mm per h) (a) 24-h alternating-block storm 0 12 24 36 48 60 72 Time (h) Remaining 72-h depth, spread uniformly (antecedent rain fills soils, RWH sumps, tanks) 24-h design depth on the final day (alternating block, Clause 2.9.1) (b) 72-h monsoon storm Illustrative — not design values (100-yr 24-h = 350 mm, 72-h = 520 mm, hourly blocks).

Figure 2.2 — (a) 24-hour alternating-block design storm; (b) 72-hour SW monsoon design storm with the 24-hour design depth on the final day. Illustrative depths only. Original drawing for this Manual. The alternating-block method follows Chow, Maidment & Mays, Applied Hydrology (1988), §14.4.

2.9.3 Other temporal patterns. Huff-type or mass-curve patterns derived from Delhi storms may be used instead of 2.9.1 and 2.9.2 only after they are published in Annex 2D. SCS Type I, IA, II and III distributions shall not be used.

2.9.4 Large catchments. For catchments of 25–5,000 km², the CWC Flood Estimation Report time-distribution curves may be used, and a sensitivity run with 2.9.1 shall be reported.

Commentary. The alternating-block storm embeds every shorter-duration design intensity in one hyetograph. That makes it conservative and consistent across durations. The 72-hour pattern puts the most intense day last. This reproduces the Delhi monsoon sequence: by the time the largest falls arrive in July and August, the water table on the Yamuna floodplain and in the Trans-Yamuna basin is within about 2 m of the surface (CGWB, as reported), the johads and parks are full, and the Yamuna, fed by the rain over its catchment above Hathnikund, may already be closing the regulators on the drains that outfall to it. SCS distributions are excluded because they come from US convective and Gulf storm data and have no basis in Delhi records.


2.10 Retention rainfall depth

2.10.1 The retention design depth is the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record, read from the zone value in Annex 2E.

2.10.2 The site must retain on site the runoff from this depth (Chapter 4). Retention earns a detention credit equal to the reduction in required detention storage found by routing with the retention in place (Clause 4.4.6). The credit is not the retained volume subtracted one-for-one.

Commentary. This follows the Kansas City Metro APWA 5600 (2025.01) Required Retention Volume concept and Georgia's 1.0-inch runoff reduction standard. Both are based on percentile storms. A percentile depth is a statistic of everyday rainfall, not an AEP value, so it is computed from the daily record rather than from the frequency curves.


2.11 Design storms for pre- and post-development comparison

2.11.1 Same storm for both scenarios. Pre- and post-development runs shall use the same design storms:

  • same AEP, duration, temporal pattern and climate factor;
  • same antecedent moisture condition (Clause 2.11.4).

The two runs differ only in land surface parameters and Tc.

2.11.2 Standard catchments. For each of the 50%, 10% and 1% AEP storms and each duration in Clause 2.5.2:

Q_post(T) ≤ 0.9 × Q_pre(T)

2.11.3 Flood-sensitive catchments (as listed in Chapter 4: the Trans-Yamuna basin, the catchments of drains No. 12 and No. 14 near ITO, the Defence Colony, Kotla Mubarakpur and Garhi drains, and the Najafgarh drain below the Kakraula regulator, and any catchment notified by the authority). The mixed-frequency rule applies:

Q_post(1% AEP, 100-yr) ≤ Q_pre(10% AEP, 10-yr), and Q_post(50% AEP, 2-yr) ≤ Q_pre(50% AEP, 2-yr),

The post-development peak is checked for each duration in Clause 2.5.2. The caps are taken at the pre-development critical duration. The 10-yr cap is the largest pre-development 10-yr peak over all durations, and the 2-yr cap is the largest pre-development 2-yr peak over all durations. Each cap applies to every post-development duration.

2.11.4 Antecedent moisture. Use AMC III (wet conditions) for every design storm of July–September, whatever its duration, in every sub-area of zone DL-Z1 (NCT of Delhi) of Annex 2A. Use AMC II (average conditions) for storms in other months, including June and the pre-monsoon and winter storms.

2.11.5 Pre-development condition. Pre-development is defined in Chapter 3: greenfield, open land in good condition for the mapped hydrologic soil group. Existing impervious cover is not counted as pre-development.

Commentary. Matching each site's post-development peak to its own pre-development peak does not protect the catchment. Denver's analysis found that 100% matching at every site still produced 106% of historic peak downstream, which led to the 90% rule. The mixed-frequency rule is stricter. It caps the 100-yr post-development release at what the undeveloped site produced in a 10-yr storm. Malaysia (DID 2008: all ARIs ≤ pre-development 2-yr) is a tropical precedent for this kind of cap. AMC III for long storms reflects that SW monsoon extremes arrive after weeks of rain. In Delhi this holds for short storms too in the wettest part of the season. The water table is within 2 m of the surface on the Yamuna floodplain and in parts of the North-West and West districts, while it lies more than 65 m deep beneath the quartzite of the Central, New Delhi and South districts (CGWB, as reported; the depths in May 2023 ranged from 1.08 to 66.84 m below ground, from a search summary of the CGWB year book). The 2018 Drainage Master Plan modelled the whole city as hydrologic soil group D, with a final infiltration rate of 0.635 mm/h (IIT Delhi, 2018). Delhi's largest days fall from late June to August and its heaviest monsoon months are July and August (IMD, 2020). This Manual therefore uses AMC III for every design storm of July–September, whatever its duration, in every sub-area of zone DL-Z1, and AMC II otherwise, including June, when the earliest storms arrive on dry ground (Clause 2.11.4). These are interim choices set by this Manual; no Delhi study has yet validated AMC classes against observed runoff.

Illustrative scale of the mixed-frequency rule. The values below are not design values. They assume a 2 ha site in the Najafgarh basin in south-west Delhi with 24-h depths of 200 mm (10-yr) and 350 mm (100-yr), SCS-CN runoff with Ia = 0.2S, and CN 70 pre-development and CN 92 post-development:

Table 2.3 — Illustrative scale of the mixed-frequency rule (not design values)

Case Runoff depth Runoff volume (2 ha)
Pre-development, 10-yr 24 h 111 mm 2,210 m³
Post-development, 100-yr 24 h 325 mm 6,500 m³

The post-development 100-yr storm generates about three times the runoff volume of the pre-development 10-yr storm. A peak-rate cap at the pre-development 10-yr level means most of the difference must be stored and released slowly, so storage of the order of 0.2 m³ per m² of site may be needed. For this reason the rule applies only in flood-sensitive catchments (Clause 2.11.3); elsewhere the 0.9 × Q_pre rule of Clause 2.11.2 applies.


2.12 Joint occurrence with tailwater

2.12.1 For outfalls under tidal or river backwater influence, the design rainfall of this chapter shall be combined with the tailwater conditions of Chapter 5 as follows. The more severe case governs.

  • (a) Design rainfall (AEP as required) with a mean high water springs (MHWS) tailwater plus the sea-level allowance.
  • (b) A 10% AEP (10-yr) 48-hour storm with the 1% AEP still-water level (tide plus surge) plus the sea-level allowance.

Delhi has no coast, so no outfall in the NCT is tidal and cases (a) and (b) do not arise. The tailwater is the Yamuna, and the trunk drains that local drains discharge into. For an outfall under river backwater, the site storm is combined with the river level under Clause 5.8.4, which pairs a design event on one side with a 10-yr event on the other in the same way as case (b). The river stage is read at the Old Railway Bridge gauge, where the warning, danger and evacuation levels are 204.50 m, 205.33 m and 206.00 m, the 1978 peak was 207.49 m, the 2023 peak 208.66 m (13 July) and the 2025 peak 207.48 m (4 September), as reported; releases from Hathnikund take about 48–50 hours to reach Delhi (as reported). When the river is high, the regulators on the drains that outfall to it are closed and runoff is stored or pumped, so storage and pumps are checked for the regulators-shut condition, with the local storm and the river peak a few days apart as in July 2023, when 153 mm fell on 8–9 July and the river peaked on 13 July. No document found in research for this Manual sets a design river level for the outfalls in Delhi, and the IIT Delhi drainage model of 2018 left regulators, gates and portable pumps out [TBC]. In the Trans-Yamuna basin the Shahdara Marginal and Left Marginal bunds (1955–56) block direct outfall: only the Relief Drain discharges to the river, and the rest of the basin's drains run away from it and are pumped (IIT Delhi, 2018). Every level is stated on a named datum, as Chapter 5 requires.

Commentary. Delhi has no coast, so no outfall is tidal and there is no storm surge; the coincident load is the stage of the Yamuna. The coincidence is on record. In July 2023, 153 mm fell on 8–9 July, the river reached 208.66 m at the Old Railway Bridge on 13 July, and the regulator of drain No. 12 near ITO failed, letting the river into ITO and Rajghat (as reported). In September 2025 the river peaked at 207.48 m on 4 September in a monsoon 41% above normal at Safdarjung (as reported; IMD, 2025). Releases from Hathnikund reach Delhi in about 48–50 hours, which gives warning of the river but not of a local storm (as reported). In the Trans-Yamuna basin the drains cannot outfall by gravity at any river level, and depend on pumps. The levels of the sources are on different datums, which is why Chapter 5 requires every level to name its datum. Because rainfall and surge share a weather cause (in Delhi, which has no coast, the counterpart of surge is the stage of the Yamuna, raised by the same monsoon systems that bring heavy rain to the city and to the catchment above Hathnikund: in July 2023 Delhi recorded 153 mm in 24 hours on 8–9 July and the river peaked at 208.66 m at the Old Railway Bridge on 13 July, as reported), they cannot be treated as independent. Case (b) is a simple joint-probability surrogate until a statistical joint analysis is adopted.


2.13 Submittal requirements

Every hydrologic submittal shall include a Design Rainfall Sheet (Form 2-1) stating:

  1. the site coordinates and zone;
  2. the source (Clause 2.3), version or access date, and a screenshot or export of the values extracted;
  3. a depth table for each AEP and duration used, before and after the fixed-interval factor, grid-to-point factor, ARF and climate factor;
  4. the cross-check values of Clause 2.3.3 and the floor check;
  5. the hyetographs used, as a table and a plot, for each design storm; and
  6. the AMC and pre-development definition adopted.

Figure 2.3 shows the steps of this chapter in the order in which the sheet records them.

Figure 2.3 — From design rainfall source to design storm Seven steps in sequence: choose the approved source; set AEPs and durations; point depth for each AEP and duration; grid to point and areal reduction; climate factor; temporal pattern; design storm. A side panel lists what Form 2-1 records, and a second panel shows that the retention depth takes a separate route without the climate factor. From design rainfall source to design storm Steps a designer follows in Chapter 2, with the governing clause (schematic flowchart) 1 Choose the approved source Cl. 2.3 NIH-DHAARA at the site coordinates. Station IDF only with ≥ 30 yr record within 10 km; the greater value governs. Report the IMD (Das et al. 2022) cross-check; CWC subzone value is a floor for 25–5,000 km². 2 Set the AEPs and durations Cl. 2.4–2.5 AEP for each element from Table 2.1. Conveyance: duration = Tc, not less than 10 min. Storage: every duration in {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48, 72 h always. 3 Point depth for each AEP and duration Cl. 2.6 Read the depth from the source for each duration. If only daily depths exist, use the Annex 2B ratios (not the one-third rule). Fixed-interval data × 1.13 / 1.04 / 1.02 for 1 / 2 / 3–4 intervals. 4 Grid to point, then areal reduction Cl. 2.7 Grid-average values × grid-to-point factor (Annex 2C). ARF = 1.0 up to 10 km²; CWC curves above 25 km², linear between. No ARF for storage on a single development site. 5 Apply the climate factor Cl. 2.8 × 1.20 for durations ≤ 6 h; × 1.10 for > 6 h to 72 h. CF = 1.0 for temporary works (design life ≤ 5 years). Not applied to the retention depth or the WQv depth. 6 Build the temporal pattern Cl. 2.9 ≤ 24 h: alternating block, peak at 50%, time step ≤ Tc/3 and ≤ 15 min. 48 / 72 h: the 24 h design depth in the final 24 h; the remainder spread uniformly before it. SCS Type I, IA, II and III are not permitted. 7 Design storm (hyetograph) Cl. 2.11–2.12 Same storms for pre- and post-development runs. AMC II for storms ≤ 6 h; AMC III for 12 h and longer. Tidal or backwater outfalls: also run the joint cases of Clause 2.12. Form 2-1 Design Rainfall Sheet (Cl. 2.13) records: 1. Site coordinates and zone 2. Source, version or access date, export 3. Depth table before and after each factor (steps 3–5) 4. Cross-checks and the CWC floor 5. Hyetographs: table and plot (steps 6–7) 6. AMC and pre- development condition Retention depth (separate route) 90th percentile wet-day (≥ 2.5 mm) 24 h depth, zone value from Annex 2E. No climate factor, no hyetograph for sizing the volume. Cl. 2.10, 2.8.3 Schematic flowchart. Clause numbers refer to Chapter 2. The order of steps 3–5 is the order of the columns of the depth table on Form 2-1.

Figure 2.3 — From design rainfall source to design storm: the steps a designer follows (source, AEPs and durations, point depth, grid-to-point and areal reduction, climate factor, temporal pattern, design storm), the clause that governs each step, what Form 2-1 records, and the separate route for the retention depth. Schematic. Original drawing for this Manual.


2.14 Review and update

2.14.1 The approving authority shall review this chapter every 10 years. It shall also review it within 2 years of any event in which recorded rainfall exceeds the 1% AEP 24-hour or 72-hour design depth at two or more approved gauges in the State.

2.14.2 Updates to NIH-DHAARA take effect for new submittals 6 months after release, unless the authority notifies otherwise.


References (chapter)

Annexes

Annex Content
2A NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map
2B Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule
2C Grid-to-point factors
2D Delhi temporal patterns (Huff curves)
2E Retention percentile depths by zone
Form 2-1 Design Rainfall Sheet