Annexes to Chapter 2Design Rainfall and Design Storms
These annexes support Chapter 2. Annexes 2A to 2E will hold the statewide rainfall tables that Chapter 2 refers to: the benchmark checks and zone map, sub-daily ratios, grid-to-point factors, temporal patterns and retention depths. Each needs analysis of NIH-DHAARA and IMD records that has not yet been done for this Manual, so each is marked "To be prepared" and gives its intended layout and the rule to use until it is published (Clause 1.11.5). Form 2-1 is a draft form for the Design Rainfall Sheet that every hydrologic submittal must include (Clause 2.13). The Manual is a draft; it is not adopted by any government or agency.
Annex 2A — NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map
Supports Clauses 2.3.1 to 2.3.5 of Chapter 2.
To be prepared. This annex will compare, at benchmark points across the State, the NIH-DHAARA design depths with frequency analyses of long IMD daily station records and of IMD gridded daily data (converted to point values with Annex 2C), for 24 hours and longer and for the AEPs of Table 2.1. It will also contain the map of rainfall zones used by Annexes 2B, 2C and 2E and by the Tier B tables of Chapter 4. It needs NIH-DHAARA values at the benchmark coordinates (NIH), IMD daily and recording-gauge station records and IMD gridded rainfall (IMD), State rain-gauge records (the block and district rain gauges whose readings IMD reports, the gauges of WRD and DVC, and any automatic gauges of the Municipal Corporations, Tata Steel UISL and the city command centres [TBC]), and district and basin boundaries (Survey of India, WRD). Until it is published, design depths are taken from NIH-DHAARA under Clause 2.3.1, the cross-checks of Clause 2.3.3 are reported on Form 2-1, and the zone of a site is the one agreed with the Authority and recorded on Form 2-1.
Table 2A.1 — Benchmark comparison of design depths (layout)
| Benchmark point | IMD station ID | Latitude, longitude | Years of record | Duration (h) | AEP | NIH-DHAARA (mm) | IMD station analysis (mm) | IMD gridded, point value (mm) | NIH-DHAARA / IMD station | Remarks |
|---|---|---|---|---|---|---|---|---|---|---|
| 24 | ||||||||||
| 48 | ||||||||||
| 72 |
2A.1 The zone names below are the working names used in the Tier B table template of Chapter 4 (Clause 4.14.2). Their boundaries, and whether further zones are needed, are to be set by the analysis of this annex.
Table 2A.2 — Rainfall zones (layout)
| Zone (working name) | Extent (districts, basins) | Representative stations | Notes |
|---|---|---|---|
| JH-Z1 Chota Nagpur plateau | The Ranchi and Hazaribagh plateaus, Parasnath, and the south-west plateau of the Brahmani headwaters: CWC subzone 1(g) (its hilly region) with the 3(d) line about 0.15–0.3° west of Ranchi, and subzone 3(d) in JH-G (Clause 2.3.6(c)); catchments that cross a zone line take the higher zone value | Ranchi (A) 42701 (daily record 1956–2012) with the station at BAU Kanke; Hazaribagh 42699 (1867–2012) | District annual normals about 1,130–1,500 mm (Kodarma 1,130.8, Lohardaga 1,181.6, Giridih 1,189.0, Hazaribagh 1,225.6, Gumla 1,277.2, Ranchi 1,307.7, Khunti 1,395.3, Simdega 1,495.8 mm; IMD, 1951–2000). FER 50-yr 24-h from less than 200 mm (Lohardaga) to about 280 mm (Giridih); 1-h ratio 0.350 (1(g)) and 0.390 (3(d)). Floors of Clause 2.3.6(h): 1 h 80–115 mm and 3 h 130–195 mm at 10–100 yr. Records: Dumri 403.4 mm (18 Jul 1975), Giridih 403.0 mm (27 Aug 1980), Mandar 382.0 mm (11 Jul 1990), Kanke 332.6 mm (5 Jul 1998), Hazaribagh 249.2 mm (24 Jun 1911), Ranchi (A) 224.3 mm (29 Jun 1994) (IMD). NIH-DHAARA 50-yr 24-h low here (Hazaribagh 148, Lohardaga 164, Gumla 172, Ranchi 196, Giridih 205 mm) |
| JH-Z1 Chota Nagpur plateau: JH-A Ranchi plateau (Subarnarekha headwaters) | Ranchi with Kanke, Namkum, Ratu and Ormanjhi, the north of Khunti district, and the Subarnarekha valley down to Muri and Silli, in subzone 1(g); the south-western wards of Ranchi round Hatia, Dhurwa and Nagri take the higher of the 1(g) and 3(d) values (Clause 2.3.6(c)); boundaries [TBC] | Ranchi (A), BAU Kanke; the district rain gauges at Kanke and Mandar (42 years each to 2006) | Granite-gneiss with laterite cappings (Ratu, Bero, Mandar); weathered zone 10–25 m, 30–60 m under laterite; 501.6 km² of Ranchi district critical (CGWB, 2023); pre-monsoon water levels to 33 m below ground (May 2022); infiltration 28–62 mm/h measured on the Jumar nala (Baxla et al., 2001). Recording-gauge maxima at Mandar: 99 mm in 1 h and 171 mm in 3 h (6 Aug 1971) (CWC FER 1(g)). Receiving waters: the Subarnarekha (Getalsud full reservoir level 590.06 m; Muri HFL 238.12 m, 2008) and its tributaries the Harmu, the Jumar, the Potpoto and the Hinoo; the Kanke, Hatia (Dhurwa) and Getalsud reservoirs, with the 20 m full-tank-level line of the Ranchi Master Plan 2037, and Bada Talab; CWC monitoring sites added in 2022 on the Jumar at Kanke Road bridge, the Gara at Dhurwa dam and the Kanchi at Paradih (CWC, as copied) |
| JH-Z1 Chota Nagpur plateau: JH-B Hazaribagh–Koderma–Giridih plateau and Parasnath | Hazaribagh, Barhi, Koderma–Jhumri Telaiya, Giridih and Dumri, Parasnath and its flanks, and the east of Chatra district on the Barakar side, in subzone 1(g), with the 1(d) line about 0.3° north-west of Hazaribagh; boundaries [TBC] | Hazaribagh 42699, Tilaiya 32355 (1956–2012) | Gneiss and the mica belt, with thin soils and Gondwana outliers (Giridih); critical and semi-critical areas in Koderma and Giridih, and fluoride in groundwater (CGWB, as reported). FER 50-yr 24-h about 240–280 mm at Hazaribagh and about 280 mm at Giridih, with a cell above 280 mm north-west of Hazaribagh; the 25-yr plate's low cell between Hazaribagh and Jhalda is contradicted by Pachamba 300.7 mm and Barhi 295.1 mm. Recording-gauge maxima: 100 mm in 1 h at Palganj (18 Sep 1978) and 127 mm in 3 h at Tilaiya (9 Aug 1970) (CWC FER 1(g)). Steep flanks of Parasnath, about 1,350–1,365 m high (sources differ). Receiving waters: the Barakar (Tilaiya HFL 372.28 m, 1986; Barkisuriya danger 289.4 m, HFL 292.32 m, 2004, conflicting [TBC]) and the Konar (DVC; HFL 427.91 m, 1961); the Lilajan and the Mohana to the north-west, in 1(d) (CWC, as copied) |
| JH-Z1 Chota Nagpur plateau: JH-G South-west plateau (Brahmani headwaters) | Lohardaga, Gumla, Simdega, the south of Khunti district, Torpa, Bano and Kolebira, in subzone 3(d); boundaries [TBC] | No long-record IMD station in the sub-area; the nearest are Ranchi (A) and Chaibasa 42795 [TBC] | Granite-gneiss with laterite and bauxite cappings (Lohardaga); the shallowest water levels in the State (0.4 m below ground at Gumla, Nov 2022; CGWB). FER 3(d) 50-yr 24-h less than 200 mm at Lohardaga (a closed low cell), about 200–240 mm at Gumla and about 240 mm at Simdega; 1-h ratio 0.390, 3-h 0.610; the 3(d) loss rate falls from about 3.5 mm/h at 3 h to 1.5 mm/h at 13 h and longer. Records: Simdega 288.0 mm (26 Jul 1996), Lohardaga 248.7 mm (26 Sep 1906), Gumla 238.8 mm (31 Aug 1925), Pakartand 212.4 mm (1 Aug 2023) (IMD). Receiving waters: the South Koel and the Sankh, with no CWC site in the State; the nearest downstream, Jaraikela in Odisha (HFL 194.07 m, 1997), was removed in 2022 (CWC, as copied) |
| JH-Z2 Lowlands and the coalfield | The Damodar coalfield belt, the Subarnarekha–Kharkai lowland and Kolhan, and the Santhal Parganas and the Ganga front, in CWC subzone 1(g) (Clause 2.3.6(c)); catchments that cross a zone line take the higher zone value | Dhanbad 42703 (1934–2012), Jamshedpur (A) 42798 (1945–2012), Jamshedpur 42799 (1923–2012), Chaibasa 42795 (1879–2012), Dumka 42599 (1901–2012) | District annual normals about 1,170–1,500 mm (Deoghar 1,174.1, West Singhbhum 1,288.2, Bokaro 1,288.3, Dhanbad 1,300.5, East Singhbhum 1,336.7, Dumka 1,405.4, Sahebganj 1,484.7, Pakur 1,500.3 mm; IMD, 1951–2000). FER 50-yr 24-h from less than 200 mm (Chaibasa) to about 280 mm (Madhupur); 1-h ratio 0.350. Floors of Clause 2.3.6(h): 1 h 80–115 mm and 3 h 130–195 mm at 10–100 yr. Records: Taljhari 601.4 mm (25 Sep 1999), the State record, Borio 570.0 mm (29 Jun 1997), Kairo 520.0 mm (21 Sep 2000), Katikund 517.0 mm (28 Jul 1986), Peterbar 374.1 mm (18 Jul 1957), Jamshedpur (A) 338.1 mm (18 Jun 2008), Dhanbad 272.0 mm (8 Aug 1913) (IMD). NIH-DHAARA 50-yr 24-h high here (Sahebganj 368, Bokaro 317, Jamshedpur 306, Chaibasa 298 mm) |
| JH-Z2 Lowlands and the coalfield: JH-C Damodar coalfield belt | Dhanbad, Jharia, Katras, Sindri, Bokaro Steel City and Chas, Bermo and Phusro, Ramgarh and Patratu, and the Karanpura coalfields; boundaries [TBC] | Dhanbad 42703; Bokaro 32599 (1951–1981), Ramgarh 32636 (1954–1985), Maithon 32609 (1957–1985) and Panchet Hills 32648 (1954–1985), as checks | Gondwana sandstone, shale and coal; overburden dumps, mine voids and pit lakes; the Jharia fires (fire area given as 1.53 km² by the Ministry of Coal in 2025-26, 1.8 km² in the press and 2.18 km² by NRSC in 2014: the figures disagree) and subsidence of about 4 to 57 cm a year in satellite studies; Bermo and Baliapur over-exploited, Dhanbad Urban and Topchanchi critical (CGWB, 2023). FER 50-yr 24-h about 240 mm (100-yr about 280 mm); the 1(g) worked example, the Saphi near Ramgarh, gives about 4.5 m³/s per km² at 50 years. Storms of 26–28 Sep 1978 (Maithon 310.8, Panchet Hills 289.0 mm; 162 mm in 6 h at Dhanbad) and 27 Sep 1995 (Nawadih 292.0, Topchanchi 274.4 mm) (IMD; CWC FER 1(g)). Receiving waters: the Damodar at Ramgarh (danger 307.51 m, HFL 316.68 m, 1978) and Pupunki (153.5 m, 160.05 m, 1976); Tenughat; DVC's Panchet and Maithon, whose "full reservoir levels" in CWC's list, 132.59 m and 150.88 m, are DVC's maximum flood levels; the Katri, the Jamunia and the Khudia; and mine voids, which are not outfalls without the lessee's and DGMS's consent (CWC, as copied) |
| JH-Z2 Lowlands and the coalfield: JH-D Subarnarekha–Kharkai lowland and Kolhan | Jamshedpur with Adityapur, Mango, Jugsalai and Bagbera, Saraikela and Gamharia, Chandil, Ghatsila, Chaibasa, Chakradharpur and Noamundi; boundaries [TBC] | Jamshedpur (A) 42798, Jamshedpur 42799, Chaibasa 42795 | Dalma volcanics, Singhbhum granite and schist, and laterite; Jamshedpur Urban and Golmuri-cum-Jugsalai over-exploited (CGWB, 2023). FER 50-yr 24-h about 240 mm at Jamshedpur, and a closed low cell of less than 200 mm at Chaibasa contradicted by Kumardungi 400.3 mm and Manjhari 401.1 mm. Records: Jamshedpur (A) 338.1 mm (18 Jun 2008) and 332.8 mm (26 Sep 1981), Ghatsila 318.2 mm (28 Jun 1997), Baharagora 306.8 mm (29 Jun 2025), Chaibasa 241.0 mm (7 Oct 2004) (IMD). Recording-gauge maxima: 184 mm in 3 h at Jamshedpur (A) (1977) and 100 mm in 1 h at Ghatsila (25 Jul 1979) (CWC FER 1(g)). Receiving waters: the Subarnarekha at Jamshedpur (warning 122.5 m, danger 123.5 m, HFL 129.82 m, 1973) and the Kharkai at Adityapur (HFL 137.8 m, 2008) (CWC, as copied); the district's danger marks of 121.50 m at Mango bridge and 129 m at Adityapur bridge are not reconciled with CWC's and are not mixed with them; Chandil dam (full reservoir level 189 m or 192 m, lists conflict [TBC]) and the Galudih barrage; releases on the Kharkai from dams in Odisha |
| JH-Z2 Lowlands and the coalfield: JH-E Santhal Parganas and Ganga front | Deoghar and Madhupur, Dumka, Jamtara, Godda, Pakur, Sahebganj and Rajmahal; boundaries [TBC] | Dumka 42599; the district rain gauges of Sahebganj, Pakur and Godda [TBC] | Rajmahal traps (basalt, vesicular in their upper part), Gondwana rocks, and Ganga alluvium with tube wells of 20–30 m; arsenic in groundwater at Sahebganj, Rajmahal and Udhwa and fluoride in Pakur (CGWB, as reported). FER 50-yr 24-h about 240–280 mm, about 280 mm at Madhupur. Records, the highest in the State: Taljhari 601.4 mm (25 Sep 1999), Borio 570.0 mm (29 Jun 1997), Kairo 520.0 mm and Sarawan 454.4 mm (21 Sep 2000), Katikund 517.0 mm (28 Jul 1986), Boarijor 450.0 mm (24 Sep 1999), Rajmahal 429.0 mm (28 Sep 1995), Dumka 300.8 mm (27 Sep 1978), Deoghar 264.2 mm (23 Sep 1917) (IMD). Receiving waters: the Ganga at Sahibganj (warning 26.25 m, danger 27.25 m, HFL 30.91 m, 1998) and Rajmahal (danger 25.99 m, HFL 26.94 m, 2003), backed up by Farakka; the Mayurakshi (Massanjore dam), the Ajay (Sikatia barrage, HFL 169.24 m, 1995) and the Gumani at Berhait (danger 47.53 m, HFL 48.8 m, 1977) (CWC, as copied); Udhwa Lake, the State's Ramsar site |
| JH-Z3 Palamu–Latehar–Garhwa | The North Koel basin and the Sone frontage in the north-west, in CWC subzone 1(d) (Clause 2.3.6(c)); catchments that cross a zone line take the higher zone value | Daltonganj 42587 (1901–2012) | District annual normals the lowest in the State, about 1,080–1,210 mm (Garhwa 1,084.5, Palamau 1,089.0, Latehar 1,197.6, Chatra 1,210.7 mm; IMD, 1951–2000). FER 1(d) 50-yr 24-h from about 240–280 mm (Garhwa) to about 320 mm (Latehar, Chatra), the highest plate values in the State, and 100-yr up to about 360 mm; 1-h ratio 0.37. Ratio floor of Clause 2.3.6(h)(i) only; the absolute floors of (h)(ii) do not apply. Records: Hunterganj 467.4 mm (1 Aug 1917), Manatu 440.0 mm (19 Aug 2003), Netarhat 429.3 mm (19 Jul 1964), Chatra 370.3 mm (2 Aug 1917), Latehar 332.7 mm (28 Jul 1953), Barwadih 318.0 mm (14 Aug 2026), Daltonganj 290.8 mm (23 Jul 1920) (IMD); 389 mm in 24 h at the Chandwa recording gauge (16–17 Sep 1976) (CWC FER 1(g)). NIH-DHAARA 50-yr 24-h close to the plates here (Daltonganj 298, Latehar 302, Chatra 309 mm) |
| JH-Z3 Palamu–Latehar–Garhwa: JH-F Palamu–Latehar–Garhwa (North Koel–Sone) | Medininagar (Daltonganj), Garhwa, Latehar, Barwadih and Netarhat, the west of Chatra district, Japla and Hussainabad; Garhwa district and the west of Palamu lie in UTM zone 44N, but zone 45N is used statewide; boundaries [TBC] | Daltonganj 42587 | Gneiss with patches of alluvium and the Gondwana rocks of the Auranga and Daltonganj coalfields; fluoride in groundwater in Palamu and Garhwa (CGWB). Receiving waters: the North Koel at Daltonganj (warning 208 m, danger 209 m, HFL 210.91 m, 1976) and Mohammadganj (danger 145.52 m, HFL 146.66 m, 2016), and the Sone at Japla (danger 125.09 m, HFL 128.04 m, 1975) (CWC, as copied); the Amanat barrage and the Anraj and Batane reservoirs |
Annex 2B — Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule
Supports Clauses 2.6.1 to 2.6.4 of Chapter 2.
To be prepared. This annex will tabulate, for each zone of Annex 2A, the ratios of the t-hour to the 24-hour design depth from NIH-DHAARA, which are derived from hourly records, against the ratios implied by IMD Das et al. (2022) and by the one-third rule. It needs NIH-DHAARA depths for each duration at representative points in each zone (NIH), IMD recording-gauge data and the IDF values of Das et al. (2022) (IMD). Until it is published, sub-daily depths are read directly from NIH-DHAARA or an approved station IDF (Clause 2.6.1). Where only daily depths are available, the ratios used are those agreed with the Authority, which in Jharkhand are those of Clause 2.3.6: the CWC Flood Estimation Report ratios for the site's subzone in Table 2B.1, raised at 1 and 3 hours to the floors of Clause 2.3.6(h) for the 10-yr and rarer storms (Clause 2.6.2), and are recorded on Form 2-1. The one-third rule is not used (Clause 2.6.4).
2B.1 The first row of Table 2B.1 gives the ratios of the one-third rule P(t) = P(24)·(t/24)^(1/3), for comparison only. The 1, 3, 6 and 12 h values are those stated in the commentary to Clause 2.6; the 2 h value is computed from the same formula. The rule shall not be used for design unless this annex confirms it for the zone concerned (Clause 2.6.4).
Table 2B.1 — Ratios P(t)/P(24h) by zone (layout)
| Zone | Source | 1 h | 2 h | 3 h | 6 h | 12 h | 24 h |
|---|---|---|---|---|---|---|---|
| All (reference only, not for design) | One-third rule | 0.35 | 0.44 | 0.50 | 0.63 | 0.79 | 1.00 |
| JH-Z1 (JH-A, JH-B) and JH-Z2 (JH-C, JH-D, JH-E) | CWC FER 1(g), 10-yr basis (interim design ratios, Clause 2.3.6(g)) | 0.350 | 0.515 | 0.640 | 0.800 | 1.00 | |
| JH-Z1 (JH-G) | CWC FER 3(d), 10-yr basis (interim design ratios, Clause 2.3.6(g)) | 0.390 | 0.610 | 0.760 | 0.860 | 1.00 | |
| JH-Z3 (JH-F) | CWC FER 1(d), 50-yr (interim design ratios, Clause 2.3.6(g)) | 0.37 | 0.58 | 0.70 | 0.89 | 1.00 | |
| All zones | Ratio floor of Clause 2.3.6(h)(i), 10–100 yr (binding in 1(g); the 1(d) and 3(d) ratios exceed it) | 0.35 | 0.57 | 1.00 | |||
| JH-Z1 and JH-Z2 | Floors of Clause 2.3.6(h)(ii) at 50-yr, as ratios to the 240 mm of the plates at Ranchi and Jamshedpur (comparison only; the floors are depths) | 0.44 | 0.73 | 1.00 | |||
| JH-Z1 (JH-A): Mandar | CWC FER 1(g), Annex 4.4: the recording-gauge maxima of 6 Aug 1971 as ratios to the 24-h maximum of the same record, 194 mm (single event, comparison only) | 0.51 | 0.88 | 0.91 | 0.94 | 1.00 | |
| JH-Z2 (JH-D): Jamshedpur (A) | CWC FER 1(g), Annex 4.4: the recording-gauge maxima of 1977 as ratios to the 24-h maximum, 193 mm (single event, comparison only; the 3-h value exceeds the 6-h value in the annex, a misprint [TBC]) | 0.95 | 0.88 | 0.91 | 1.00 | ||
| JH-Z1 (JH-A): Ranchi | NIH-DHAARA, 50-yr, Ranchi cell (comparison only; 3- and 6-hour values not queried) | 0.23 | 0.35 | 0.77 | 1.00 | ||
| JH-Z1 (JH-B): Hazaribagh | NIH-DHAARA, 50-yr, Hazaribagh cell (comparison only; 3- and 6-hour values not queried) | 0.30 | 0.44 | 0.77 | 1.00 | ||
| JH-Z2 (JH-C): Dhanbad | NIH-DHAARA, 50-yr, Dhanbad cell (comparison only; 3- and 6-hour values not queried) | 0.29 | 0.44 | 0.81 | 1.00 | ||
| JH-Z2 (JH-D): Jamshedpur | NIH-DHAARA, 50-yr, Jamshedpur cell (comparison only; 3- and 6-hour values not queried) | 0.26 | 0.42 | 0.79 | 1.00 |
2B.2 Depths from fixed observation windows are converted to true-interval depths with the factors of Clause 2.6.3, repeated in Table 2B.2. They are the standard WMO (Hershfield) values and are not provisional.
Table 2B.2 — Fixed-interval adjustment factors (Clause 2.6.3)
| Number of fixed observation intervals in the duration | Factor |
|---|---|
| 1 | 1.13 |
| 2 | 1.04 |
| 3–4 | 1.02 |
Annex 2C — Grid-to-point factors
Supports Clauses 2.7.1 and 2.7.4 of Chapter 2.
To be prepared. This annex will give the factors that convert grid-average design depths (for example from 0.25° cells) to point depths, by zone, duration and AEP. It needs paired frequency analyses of IMD gridded rainfall and of the IMD and State gauges inside each cell (IMD, WRD, DVC and the block rain gauges of the State [TBC]), the benchmark points of Annex 2A, and a stated method for deriving the factors. Until it is published, design depths are taken as point values from NIH-DHAARA or an approved station IDF (Clauses 2.3.1 and 2.3.2). Grid-average values are not used as design depths unless a conversion agreed with the Authority is recorded on Form 2-1 (Clause 1.11.5).
2C.1 The commentary to Clause 2.7 shows why the factors matter, and in Jharkhand the reanalysis cells err in both directions. On the plateau they err low: the IMDAA cell of NIH-DHAARA (about 12 km) at Hazaribagh gives a 50-year 24-hour depth of about 148 mm and a 100-year depth of about 166 mm, against a CWC plate value of about 240–280 mm and the 249.2 mm recorded at the Hazaribagh observatory on 24 June 1911; at Ranchi about 196 mm, against about 240 mm and the 332.6 mm and 382.0 mm recorded at Kanke and Mandar; at Giridih about 205 mm, against about 280 mm and the 403.0 mm of 27 August 1980; and at Lohardaga and Gumla about 164 and 172 mm. In the lowlands and on the Ganga front they err high: about 368 mm at Sahebganj, 317 mm at Bokaro, 306 mm at Jamshedpur and 298 mm at Chaibasa, against plate values of about 200–280 mm, though the station records there, 601.4 mm at Taljhari and 338.1 mm at Jamshedpur (A), show that the plates are themselves exceeded. The cells' 50-year 1-hour depths, about 42–87 mm, are 0.20–0.32 of their 24-hour depths, and at Ranchi 45.0 mm (NIH-DHAARA, queried 7 Nov 2026; IMD; CWC). Values of this kind are grid-average values and need these factors before any use as point depths; under Clause 2.3.6 they are not used as design depths in Jharkhand until this annex and Annex 2A are published.
Table 2C.1 — Grid-to-point factors (layout)
| Zone | Grid product and cell size | Duration (h) | AEP | Factor (point / grid) | Stations used | Years of record |
|---|---|---|---|---|---|---|
| 24 | ||||||
| 48 | ||||||
| 72 |
Annex 2D — Jharkhand temporal patterns (Huff curves)
Supports Clauses 2.9.3 and 2.9.4 of Chapter 2, and Clause 11.7.3 of Chapter 11.
To be prepared. This annex will give dimensionless time-distribution (mass) curves of Jharkhand storms, in the form introduced by Huff (1967), by zone, storm-duration class and quartile, at stated probability levels. It needs storm hyetographs from recording gauges and automatic weather stations (IMD, its automatic weather stations and automatic rain gauges in the State, under the Meteorological Centre Ranchi, such as the station at BAU Kanke, and any recording gauges of DVC and WRD [TBC]), separated into independent storms by a stated rule, and the storms of 16–17 September 1976 over the North Koel at Chandwa, 27 September 1978 at Maithon, Dumka and Panchet Hills, 24–25 September 1999 at Taljhari and Sahebganj, 21 September 2000 at Kairo and Sarawan and 18 June 2008 at Jamshedpur (A), the short bursts of 6 August 1971 at Mandar and 5 August 1977 at Jamshedpur (A), and the rain of Cyclone Yaas on 26–27 May 2021 among them. Until it is published, design storms use the alternating-block pattern of Clause 2.9.1 and the 48- and 72-hour pattern of Clause 2.9.2; for catchments of 25–5,000 km², the CWC Flood Estimation Report curves may be used with a sensitivity run under Clause 2.9.1 (Clause 2.9.4). SCS Type distributions are not used (Clause 2.9.3). For the disaggregation of daily records in continuous simulation (Clause 11.7.3), the method is agreed with the Authority and recorded (Clause 1.11.5).
Table 2D.1 — Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)
| Fraction of storm time | 0 | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 10% probability curve | 0 | 1.0 | |||||||||
| 50% probability curve | 0 | 1.0 | |||||||||
| 90% probability curve | 0 | 1.0 |
2D.1 Each table shall state the zone, the duration class, the quartile (the quarter of the storm in which most rain fell), the number of storms analysed and the period of record.
Reference: Huff, F.A. (1967). Time distribution of rainfall in heavy storms. Water Resources Research 3(4), 1007–1019.
Annex 2E — Retention percentile depths by zone
Supports Clauses 2.8.3 and 2.10.1 to 2.10.2 of Chapter 2, Clause 4.4 of Chapter 4 and Chapter 8.
To be prepared. This annex will give, for each zone of Annex 2A, the retention design depth P_R: the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record (Clause 2.10.1). It needs long daily records at stations in each zone (IMD, WRD, DVC and the block rain gauges of the State [TBC]) and IMD gridded data with the factors of Annex 2C where stations are sparse. Until it is published, P_R is computed by the definition of Clause 2.10.1 from the long-term daily record of a station agreed with the Authority, by the steps in 2E.1, and recorded on Form 2-1 (Clause 1.11.5).
2E.1 Computing P_R from a daily record.
- Take the daily (24-hour) rainfall series of the station for its full record.
- Keep only the days with rain of 2.5 mm or more (wet days).
- Rank the wet-day depths and take the depth not exceeded on 90% of them (the 90th percentile).
- Do not apply the climate factor (Clause 2.8.3) or the fixed-interval factor; P_R is a statistic of everyday rainfall, not an AEP design depth.
- Record the station, the period of record, the number of wet days and P_R on Form 2-1.
Table 2E.1 — Retention depth P_R by zone (layout)
| Zone | Stations or grid cells used | Period of record | Number of wet days (≥ 2.5 mm) | P_R, 90th percentile (mm) | Issued on |
|---|---|---|---|---|---|
| JH-Z1 Chota Nagpur plateau | |||||
| JH-Z2 Lowlands and the coalfield | |||||
| JH-Z3 Palamu–Latehar–Garhwa |
Form 2-1 — Design Rainfall Sheet
Supports Clauses 2.3 to 2.13 of Chapter 2, and Clause 10.4.1(d) of Chapter 10.
Draft form — Jharkhand Stormwater Design Manual, Draft v1.0. One sheet for each hydrologic submittal. The steps follow Figure 2.3 of Chapter 2.
Table 2F.1 — Form 2-1: site, source and storms
| No. | Item (clause) | Entry |
|---|---|---|
| A. Site (Clause 2.13, item 1) | ||
| A1 | Project and site | ______ |
| A2 | Site coordinates (latitude, longitude, decimal degrees) | ______ |
| A3 | Rainfall zone (Annex 2A, or as agreed with the Authority) | ______ |
| A4 | Contributing catchment area (km²) (Clause 2.7) | ______ |
| A5 | Design life: more than 25 years / temporary works, 5 years or less (Clause 2.8.2) | ______ |
| A6 | Outfall under tidal or river backwater influence: Yes / No (Clauses 2.5.3, 2.12) | ______ |
| B. Source (Clauses 2.3, 2.3.5; item 2) | ||
| B1 | NIH-DHAARA: version or access date | ______ |
| B2 | Coordinates queried | ______ |
| B3 | Screenshot or export of the values extracted attached: reference | ______ |
| B4 | Station IDF used (Clause 2.3.2): No / Yes — station, ID, distance from site (km) | ______ |
| B5 | Station IDF: years of recording-gauge data (30 or more); published or approved by | ______ |
| B6 | Station IDF: change of terrain or coastal exposure between gauge and site: None / describe | ______ |
| C. AEPs and durations (Clauses 2.4, 2.5) | ||
| C1 | Elements designed and their AEPs (Table 2.1) | ______ |
| C2 | Conveyance: Tc and design duration (not less than 10 min) (Clause 2.5.1) | ______ |
| C3 | Storage: durations checked from {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48 and 72 h included (Clause 2.5.2) | ______ |
| C4 | Critical duration found for each storage element | ______ |
| D. Conversions | ||
| D1 | Sub-daily depths: read directly / from Annex 2B ratios / from ratios agreed with the Authority (Clauses 2.6.1, 2.6.2) | ______ |
| D2 | Fixed-interval factor applied: none (true-interval source) / 1.13 / 1.04 / 1.02 (Clause 2.6.3) | ______ |
| D3 | Grid-to-point factor: not needed (point source) / Annex 2C / agreed value (Clause 2.7.1) | ______ |
| D4 | ARF: 1.0 (10 km² or less; single-site storage) / CWC curve / interpolated (Clauses 2.7.2–2.7.4) | ______ |
| D5 | Climate factor: 1.20 (≤ 6 h) and 1.10 (> 6–72 h) / 1.0 temporary works / projected depths under Clause 2.8.4 | ______ |
| E. Cross-checks (Clause 2.3.3; item 4) | ||
| E1 | IMD Das et al. (2022) values for 1–24 h: reported in Table 2F.2 | ______ |
| E2 | CWC subzone 1(d), 1(g) or 3(d) 24-hour point value, catchments of 25–5,000 km²: subzone used | ______ |
| E3 | CWC floor governs for any AEP: No / Yes — AEPs | ______ |
| F. Retention depth (Clause 2.10) | ||
| F1 | P_R (mm) and source: Annex 2E zone value / computed under Annex 2E, 2E.1 — station and period | ______ |
| F2 | No climate factor applied to P_R (Clause 2.8.3): confirmed | ______ |
| G. Design storms (Clauses 2.9, 2.11, 2.12; items 5 and 6) | ||
| G1 | Storms up to 24 h: alternating block, peak at 50%; time step (≤ Tc/3 and ≤ 15 min) | ______ |
| G2 | 48 and 72 h storms: built under Clause 2.9.2 (Table 2F.3) | ______ |
| G3 | Other pattern used: none / Annex 2D / CWC FER with sensitivity run (Clauses 2.9.3, 2.9.4) | ______ |
| G4 | Hyetographs attached as a table and a plot for each design storm: reference | ______ |
| G5 | AMC: III for every design storm of 1 July–30 September in JH-C, JH-D and JH-E and on river floodplains, and of July–August in JH-A, JH-B, JH-F and JH-G, whatever its duration; at any other site or time, III for a storm that follows or contains a 5-day total of more than 53 mm; II otherwise (Clause 2.11.4) | ______ |
| G6 | Pre-development condition: greenfield, open land in good condition for the mapped HSG (Clause 2.11.5) | ______ |
| G7 | Release criterion: standard, Q_post ≤ 0.9 × Q_pre (Clause 2.11.2) / flood-sensitive, mixed-frequency rule (Clause 2.11.3) | ______ |
| G8 | Tailwater joint cases run (Clause 2.12): case (a) MHWS + sea-level allowance; case (b) 10% AEP 48 h storm with 1% AEP still-water level + sea-level allowance; governing case | ______ |
| H. Prepared by | ||
| H1 | I confirm that the values above are those extracted and used in the submittal. Name, registration number, signature, date | ______ |
Design depth = source depth × fixed-interval factor × grid-to-point factor × ARF × climate factor. Where the design depth is lower than the CWC floor for the same AEP, the floor is adopted (Clause 2.3.3).
Table 2F.2 — Form 2-1: depth table (Clause 2.13, item 3)
| AEP (T-yr) | Duration | Source depth (mm) | Fixed-interval factor | Grid-to-point factor | ARF | Climate factor | Design depth (mm) | IMD Das et al. (2022) (mm) | CWC floor (mm) | Adopted depth (mm) |
|---|---|---|---|---|---|---|---|---|---|---|
Table 2F.3 — Form 2-1: 48- and 72-hour storm construction (Clause 2.9.2)
| AEP (T-yr) | Duration (h) | Total design depth (mm) | 24 h design depth, final 24 h (mm) | Remainder (mm) | Hours before the final 24 h | Uniform intensity before the final 24 h (mm/h) |
|---|---|---|---|---|---|---|
| 48 | 24 | |||||
| 72 | 48 |