Chapter 2Design Rainfall and Design Storms
2.1 Purpose and scope
2.1.1 This chapter sets the rainfall inputs for every hydrologic calculation in this Manual: drain and inlet sizing (Chapter 6), retention and detention sizing (Chapter 4), downstream and tailwater analysis (Chapter 5), and waterbody and tank works (Chapter 7).
2.1.2 It specifies:
- (a) the approved sources of design rainfall depth and intensity;
- (b) how depths are converted between durations, between point and area, and from present to future climate;
- (c) how design storms (hyetographs) are constructed; and
- (d) the storms that must be applied to pre- and post-development conditions.
2.1.3 This chapter applies throughout West Bengal. Where a Municipal Corporation, a Municipality, NKDA or a development authority has adopted a stricter rainfall standard under Chapter 1, the stricter standard governs.
2.2 Definitions
| Term | Meaning in this Manual |
|---|---|
| Annual exceedance probability (AEP) | Probability that a given rainfall depth is equalled or exceeded in any one year. A 1% AEP storm is the "100-year" storm. Both forms are used here: T-year = 1/AEP. |
| IDF / DDF | Intensity–duration–frequency and depth–duration–frequency relationships for a location. |
| Point rainfall | Rainfall at a single location, as measured by a rain gauge. |
| Design storm | A hyetograph (rainfall depth versus time) of stated AEP, duration and temporal pattern. |
| Critical duration | The storm duration that produces the largest peak flow, water level or storage requirement for the element being designed. |
| Areal reduction factor (ARF) | Ratio of catchment-average rainfall to point rainfall for the same AEP and duration. |
| SW monsoon season (JJAS) | June–September, when the State receives about three-quarters of its annual rainfall: a State mean of 1,418.7 mm in June–September out of 1,851.4 mm a year, for 1989–2018 (IMD, 2020). Annual means range from about 1,259 mm in Nadia and 1,852 mm in Kolkata to 3,334 mm in Darjeeling and 3,721 mm in Jalpaiguri (IMD, 2020). Onset is in the first week of June in most districts and in the third week in Purulia, and withdrawal in the fourth week of September (ICAR-CRIDA). The antecedent moisture rule of Clause 2.11.4 refers to this season; the pre-monsoon deadline of 15 May is set ahead of both this season and the May cyclones. |
| Pre-monsoon and cyclone months (May, October and November) | Months outside the season in which nor'westers, and cyclones and depressions from the Bay of Bengal, bring some of the State's largest storms. With the SW monsoon season they form the design season of this Manual: no design storm, works deadline or operating rule shall assume that heavy rain is confined to June–September. In the delta, rain in May is "of the same order as that in the month of October" (CWC, 1994). May records include 220.0 mm in 24 hours at Dum Dum on 8 May 1949, 295.1 mm at Contai on 28 May 1960, 353.2 mm at Cooch Behar on 28 May 1989, 312.8 mm at Jalpaiguri on 24 May 1999 and 290.7 mm at Diamond Harbour on 27 May 1993, the last that station's all-time 24-hour record; October and November records include 419.2 mm at Kalimpong on 5 October 1968, 325.1 mm at Midnapore on 17 October 1942 and 286.3 mm at Berhampore on 31 October 1917, each the station's 24-hour record (IMD). Cyclones Aila (25 May 2009), Amphan (20 May 2020), Yaas (26 May 2021) and Remal (26 May 2024) all struck in late May. Design statistics use annual maxima from all seasons, and Clause 2.11.4 applies AMC III to the design storms of these months in the Coastal belt and Sundarbans zone. |
| Climate factor (CF) | Multiplier applied to present-day design depths to represent the design-life climate. |
| Approved source | A rainfall source listed in Clause 2.3. |
2.3 Approved sources of design rainfall
2.3.1 Primary source. Design rainfall depths and intensities shall be taken from the National Institute of Hydrology, Roorkee NIH-DHAARA platform (Design Hydrology and Advanced Rainfall Analysis, nihdhaara.in). Use its IDF / frequency tools for the site's coordinates, for each duration and AEP required by Clause 2.4. In West Bengal this clause is suspended until Annex 2A is published: Clause 2.3.6 sets the interim source.
2.3.2 Station IDF. A station-specific IDF relationship may be used in place of 2.3.1 only if all of the following hold:
- (a) it is derived from at least 30 years of recording-gauge (hourly or finer) data;
- (b) it has been published or approved by IMD, the State Hydrology Authority or the approving authority; and
- (c) the gauge is within 10 km of the site, with no major change of terrain or coastal exposure in between.
Where a station IDF is used, the design value shall be the greater of the station value and the NIH-DHAARA value.
2.3.3 Cross-checks (mandatory, not alternatives). The designer shall report, but need not adopt, the following values for comparison:
- (a) the IMD isopluvial / IDF values of Das et al. (2022), MAUSAM 73(4), for durations of 1–24 h;
- (b) for catchments of 25–5,000 km², the 24-hour point rainfall from the CWC Flood Estimation Report for subzone 1(f) (Middle Ganga Plains), 1(g) (Lower Ganga Plains) or 2(a) (North Brahmaputra), as applicable.
Where the design value is lower than the CWC 1(f)/1(g)/2(a) value for the same AEP, the CWC value shall be adopted as a floor.
2.3.4 Not permitted. None of the following shall be used as a design rainfall source:
- (a) generalised all-India IDF formulae (for example Kothyari & Garde, 1992);
- (b) rainfall values that cite no source, including vendor or web-calculator tables;
- (c) single-event maxima; or
- (d) design intensities carried forward from a previous project without a stated AEP.
Figure 2.1 — Design rainfall source hierarchy and adjustment sequence. Original drawing for this Manual.
2.3.5 Version control. Every submittal shall record the source, its version or access date, the coordinates queried, and the values extracted (Clause 2.13).
2.3.6 Interim source in West Bengal. Until Annex 2A is published and confirms NIH-DHAARA, or an approved station IDF, for a zone, Clause 2.3.1 does not apply in West Bengal, and design rainfall shall be taken as follows:
- (a) 24-hour depth, 4%, 2% and 1% AEP (25-, 50- and 100-yr). The 24-hour point value at the site read from the isopluvial plates of the CWC Flood Estimation Report for the subzone that contains the site, whatever the catchment area: 1(g) (Lower Ganga Plains, revised 1994) in all of south Bengal, from Birbhum and Murshidabad to the coast, in both its hilly region (Purulia, the west of Bankura and the Asansol–Durgapur area) and its plain region (the delta, including the Kolkata Metropolitan Area), which is most of the State; 2(a) (North Brahmaputra) in the Teesta, Jaldhaka and Torsa basins, in Darjeeling, Kalimpong, Jalpaiguri, Alipurduar and Cooch Behar districts; and 1(f) (Middle Ganga Plains) in Malda, Uttar Dinajpur and Dakshin Dinajpur and on the Mahananda side of Siliguri (Annex 2A). Within 5 km of a subzone boundary, and wherever the plates of two reports cover the site, the higher of the two plate values is used; Siliguri lies on the boundary of 1(f) and 2(a), and the higher value is used throughout the area of the Siliguri Municipal Corporation. Where no plate for one of these AEPs can be read for the site, the depth for that AEP is the station estimate of (b), and is recorded as such on Form 2-1. For orientation only, the plates give about 280–320 mm at Kolkata and Howrah, 320–360 mm at Haldia and Diamond Harbour, about 360 mm at Digha and Contai, 200–240 mm at Asansol and Durgapur, 240–280 mm at Purulia, 280–360 mm at Malda, about 320 mm at Siliguri, 360–400 mm at Jalpaiguri and Cooch Behar, and more than 480 mm in the Buxa–Jayanti duars for the 50-year storm.
- (b) 24-hour depth, more frequent AEPs (2-, 5- and 10-yr). The reports have no plates for these. The depth is the Gumbel (EV1) estimate from the annual maximum daily rainfall series, of all months, of the IMD station agreed with the Authority, multiplied by the fixed-interval factor of Clause 2.6.3. In the Kolkata Metropolitan Area it is the higher of the estimates for Kolkata (Alipore), 42807, and Kolkata (Dum Dum) (A), 42809; elsewhere the station is, for example, Bagdogra (A), 42398, for Siliguri; Jalpaiguri, 42399; Cooch Behar (A), 42403; Malda, 42503; Bankura, 42707; Haldia, 02206; or Darjeeling, 42295; or else the nearest IMD station with 30 or more years of record, from the candidates in Annex 2A.
- (c) 48- and 72-hour depths. The Gumbel estimate from the annual maximum 2-day and 3-day rainfall series of the same station or stations, with the fixed-interval factors of Clause 2.6.3, and not less than the 24-hour depth for the same AEP.
- (d) Durations shorter than 24 hours. The 24-hour depth multiplied by the ratios of the report for the site's subzone in Table 2B.1, at every AEP. The 1-hour ratio is 0.350 in 1(g), 0.260 in 2(a) and 0.31 in 1(f). Where (a) takes the higher of two subzones, the depth at each duration is the higher of the two products. Between the tabulated durations the ratio is interpolated on logarithmic axes. Below 1 hour, the ratio is agreed with the Authority and recorded on Form 2-1 until Annex 2B gives one.
- (e) Short storms. In the Kolkata Metropolitan Area the 1-hour depths given by (d), about 98–112 mm for the 50-year storm, are close to the largest hourly falls on record, 100 mm at Dum Dum on 24 August 1987 and 98 mm at Alipore on 23 September 2025. The recorded 3-hour falls, 207 mm at Dum Dum on 25–26 August 1984 and 185.6 mm at Alipore on 23 September 2025, exceed the 50-year 3-hour depths of (d), about 144–165 mm; and the 24-hour records at Alipore (369.6 mm, 28 September 1978) and Dum Dum (383.2 mm, 6 June 1984) exceed the 100-year plate value, about 320–360 mm (IMD; CWC). Whether the plates understate the extremes of the delta is not resolved; a frequency analysis of the Alipore and Dum Dum recording-gauge series under Annexes 2A and 2B is needed to show it. Until Annex 2B is published, the depths of (d) are used as they stand, and are not reduced towards NIH-DHAARA.
- (f) NIH-DHAARA. Its present-day values at the site are reported on Form 2-1 beside the interim values, for comparison only. Its projected depths are not used under Clause 2.8.4; the ratio of its projected to its present-day depths may be reported as a check on the climate factors of Table 2.2, which apply.
- (g) Other clauses. Where Clauses 2.3.2, 2.6.1, 2.7.1 and 2.13, Annexes 2A to 2C and Form 2-1 refer to the NIH-DHAARA value, the value under this clause is meant.
Commentary. NIH-DHAARA is a national, publicly accessible product from a Government of India institution, and it can be queried at any point in the State. That makes it a reproducible default that an approving authority can check. NIH-DHAARA's sub-daily values are derived from hourly records, not disaggregated from daily totals. That makes it the only public source suitable for sizing drains, which depend on short-duration intensity. Its values should still be checked against the long IMD daily record at 24 hours and longer (Annex 2A). In West Bengal the platform does not yet meet that purpose. Its present-day values there come from IMDAA reanalysis (about 12 km) for 2000–2022, not from gauges. Near Kolkata they agree with the CWC report: about 294 mm for the 50-year 24-hour depth against about 280–320 mm on the 1(g) plates, and about 90 mm for the 50-year 1-hour depth, close to the 98 mm Alipore hour of 23 September 2025 and the 100 mm Dum Dum hour of 24 August 1987. In the north and on the coast they are far higher than the plates and than any gauge record: about 677 mm at Siliguri against about 320 mm, 790 mm at Cooch Behar against about 360–400 mm (the IMD station record there is 417.3 mm), 533 mm at Jalpaiguri against about 360–400 mm, and 631 mm at Digha against about 360 mm (Digha's record is 325.3 mm and Contai's 447.1 mm) (NIH-DHAARA, queried 6 Nov 2026; IMD; CWC). A source that matches the gauges in one part of the State and doubles them in another cannot be adopted zone by zone until the benchmark checks of Annex 2A show where it holds. Clause 2.3.6 therefore uses the CWC reports and the long IMD station records until Annex 2A has been done, and uses NIH-DHAARA for comparison and as a check on the climate factors only. The interim rules for the more frequent AEPs, the 48- and 72-hour depths, the subzone boundaries, the Siliguri and Kolkata rules and durations between the tabulated ratios are set by this Manual. Two points in the reports are unresolved: the 1(f) report was read only through an OCR text of the scanned copy, so its ratios and plate values are to be checked against the page images before Annex 2B is issued [TBC]; and the 1(g) ratios were derived for the 10-year storm, the report stating that those for longer return periods are "comparable". IMD Das et al. (2022) has no panel for any West Bengal station, so the cross-check of Clause 2.3.3(a) is recorded on Form 2-1 as not available; its range for the Gangetic Plain as a whole (4–16 cm in 1 hour and 12–42 cm in 24 hours, for 2–100 years) is too wide to serve as a check.
2.4 Design return periods (summary)
2.4.1 Design AEPs are set in the chapters for each element. They are summarised here so that the correct rainfall is extracted at the start of design.
Table 2.1 — Design return periods (summary)
| Element | Design AEP (return period) | Check event | Chapter |
|---|---|---|---|
| Minor drains: Kolkata, Howrah and Bidhannagar core and high-density areas | 10% (10-yr) | 1% (100-yr) overland path | 6 |
| Minor drains: other Class I urban areas | 20% (5-yr) | 1% overland path | 6 |
| Minor drains: other areas | 50% (2-yr) | 1% overland path | 6 |
| Arterial roads and crossings | 2–4% (25–50-yr) | next higher AEP | 6 |
| Collector / local roads | 4% / 10% (25 / 10-yr) | 2% / 4% (50 / 25-yr), plus the 1% overland path | 6 |
| Major (overland) system | 1% (100-yr) | — | 6 |
| Retention volume | Percentile daily rainfall (Clause 2.10) | — | 4 |
| Detention: standard catchments | 50%, 10%, 1% (2, 10, 100-yr) | 1% emergency spillway | 4 |
| Detention: flood-sensitive catchments | Mixed-frequency rule, Clause 2.11 | 1% | 4 |
| Building floor levels | 1% + 0.5 m freeboard | — | 6 |
| Detention emergency spillway | 1% with outlet blocked | 0.2% (500-yr) where high hazard | 4 |
Commentary. These values exceed the CPHEEO (2019) national advisory minimums of 5-yr (Class I cities) and 2-yr (other areas). CPHEEO allows a State to set higher values. The values are set in Chapters 4 and 6, and the table is reproduced here for convenience.
2.5 Design durations
2.5.1 Conveyance elements (pipes, open drains, inlets, culverts) shall be designed with the intensity for a duration equal to the time of concentration (Tc) of the contributing area (Chapter 3). The minimum duration is 10 minutes.
2.5.2 Storage elements (detention, retention, tanks, pumped sumps) shall be checked for every duration in the set {1, 2, 3, 6, 12, 24, 48, 72 h}. The largest required storage or water level governs. The 24-, 48- and 72-hour storms are mandatory checks at every site, whatever the critical-duration result.
2.5.3 Tidally influenced outfalls. For storage draining to a tidally influenced outfall (Chapter 5), the 48- and 72-hour storms shall also be run with the tailwater boundary of Clause 2.12.
Commentary. West Bengal's worst rainfall floods have come from long spells. On 26–29 September 1978 a monsoon depression gave 369.6 mm in a day at Alipore, 409.3 mm at Uluberia, 400.0 mm at Suri and 387.7 mm at Durgapur, and September 1978 is the wettest month on record at Uluberia, Durgapur and Suri (IMD); the gauge at Durgapur took 388 mm in 24 hours, of which 308 mm fell in 12 hours (CWC, 1994). In September 2024 days of rain over the Damodar basin filled the DVC reservoirs, and their combined release then peaked at about 2.5 lakh cusecs on 17 September (as reported). Monthly totals show the scale: Alipore recorded 1,157.0 mm in September 1900, Uluberia 1,066.6 mm in September 1978 and Bagdogra, by Siliguri, 2,524.1 mm in June 1995 (IMD). A rule based only on critical duration, applied to a small site, picks a 1–2 hour storm and misses this failure mode. That is why the long-duration checks are mandatory.
2.6 Sub-daily rainfall
2.6.1 Where NIH-DHAARA or an approved station IDF provides values directly for the required duration, those values shall be used.
2.6.2 Where only daily (24-hour) depths are available for a duration below 24 hours, the sub-daily depth shall be derived using the ratio set of Annex 2B. These are duration-to-24-hour ratios calibrated to West Bengal recording gauges. They shall not be lower than the ratios of the CWC Flood Estimation Report for the subzone. IMD Das et al. (2022) has no West Bengal station panel and is not used as a floor in West Bengal.
2.6.3 Fixed-interval adjustment. Depths from fixed observation windows (for example 08:30–08:30 IST daily data, or clock-hour data) shall be converted to sliding-window ("true interval") depths:
- 1.13 for a single fixed observation interval;
- 1.04 for 2 intervals;
- 1.02 for 3–4 intervals.
This adjustment does not apply where the approved source already gives true-interval values.
2.6.4 The empirical relationship P(t) = P(24)·(t/24)^(1/3) shall not be used for design unless Annex 2B confirms it for the zone concerned.
Commentary. The one-third power rule is common in Indian project reports, but no primary IMD source for it was found during research for this Manual. It applies one fixed curve shape everywhere: P(1h)/P(24h) = 0.35, P(3h) = 0.50, P(6h) = 0.63 and P(12h) = 0.79. It cannot represent the difference between a short convective burst and a long SW monsoon soak, and it tends to understate short-duration depths in convective coastal storms. Annex 2B shall tabulate the NIH-DHAARA ratios P(t)/P(24h) against these values by zone. That comparison shows whether the rule is acceptable anywhere in the State and corrects older daily-based analyses. The fixed-interval factors are the standard WMO (Hershfield) values. The IMD 2022 study applies similar clock-hour to any-hour corrections.
2.7 Point, grid and areal rainfall
2.7.1 Design depths are point values. Where an approved source provides grid-average values (for example 0.25° cells), they shall be converted to point values with the grid-to-point factors in Annex 2C before use.
2.7.2 For catchments ≤ 10 km², ARF = 1.0.
2.7.3 For catchments > 10 km², apply ARF as follows:
- for 25–5,000 km² in subzone 1(f), 1(g) or 2(a): use the ARF curves of the applicable CWC Flood Estimation Report;
- for 10–25 km²: interpolate linearly between ARF = 1.0 at 10 km² and the CWC value at 25 km².
2.7.4 An ARF shall never be applied to storage design for a single development site.
Commentary. Gridded and district-average return levels are much lower than point values. For example, NIH-DHAARA's IMDAA cell at Dum Dum gives a 50-year 24-hour depth of about 244 mm, some 15% below the 280–320 mm of the CWC isopluvials, although the Dum Dum gauge has recorded 383.2 mm in a day; and on 23 September 2025 a KMC gauge at Garia was reported to have taken 332 mm while the IMD gauge at Alipore took 251.4 mm (NIH-DHAARA, queried 6 Nov 2026; IMD; CWC; as reported). In West Bengal the reanalysis cells also err the other way: in the north and on the coast they give up to about twice the plate values and the gauge records, as at Siliguri and Cooch Behar (Clause 2.3.6). Neither error can be corrected without the factors of Annex 2C. Using grid values as point values without correction would make site-level design unsafe.
2.8 Climate factor
2.8.1 Until a statewide future-climate rainfall product is adopted, present-day design depths shall be multiplied by the following interim climate factors:
Table 2.2 — Interim climate factors
| Duration | Climate factor (CF) |
|---|---|
| ≤ 6 h | 1.20 |
| > 6 h to 72 h | 1.10 |
2.8.2 The CF applies to all elements with a design life of more than 25 years. For temporary works (design life ≤ 5 years), CF = 1.0.
2.8.3 The climate factor does not apply to the retention depth (Clause 2.10) or to the water quality volume depth (Chapter 8). Those depths are percentile or frequent-event statistics of everyday rainfall, not AEP design values.
2.8.4 Where NIH-DHAARA, or a product adopted on review under Clause 2.14, provides projected future-climate depths, those depths shall replace the interim factors.
Commentary. CPHEEO (2019) considers a fixed climate factor "not feasible" nationally and recommends trend testing instead. That leaves designers without a usable number. The 1.20 short-duration factor matches the UK value cited by CPHEEO itself. It is at or below published projections for India: Ali and Mishra (2018) project 3-hourly 100-year maxima rising by about 20% at 1.5 °C and 25% at 2.0 °C of warming. No West Bengal or city design uplift factor was found. IMD's monograph for the State found, for 1989–2018, a significant increase in heavy-rainfall days in Alipurduar, Jalpaiguri, Kalimpong, Purulia, Bankura, both Medinipurs and both 24 Parganas, a decrease in Malda, Nadia and Murshidabad, and no significant change in Kolkata district (IMD, 2020). Kolkata's short-duration extremes are not new: the 207 mm that fell at Dum Dum in 3 hours in August 1984 exceeds the 185.6 mm of September 2025 (CWC, 1994; IMD, 2025). Two studies that include Kolkata in non-stationary IDF analyses (Vinnarasi and Dhanya, 2022; Ghate and Timbadiya, 2023) were not read. NIH-DHAARA's bias-corrected CMIP6 runs could give a ratio of future to present depths; none has yet been computed for this Manual, and under Clause 2.3.6(f) it would serve only as a check. The factors of Table 2.2 are therefore interim values, not West Bengal estimates.
2.9 Temporal patterns (design hyetographs)
2.9.1 Storms up to 24 hours. Use the nested alternating-block method:
- construct the storm from the same IDF relationship (after the climate factor), at time steps no longer than Tc/3 and no longer than 15 minutes;
- place the peak block at 50% of the storm duration.
2.9.2 48- and 72-hour storms (SW monsoon pattern). Construct as follows:
- (a) The total storm depth equals the design depth for the full duration (48 or 72 h).
- (b) The final 24 hours contain the 24-hour design depth for the same AEP, distributed by the alternating-block method of 2.9.1.
- (c) The remaining depth (total minus the 24-hour depth) is spread uniformly over the preceding 24 or 48 hours.
Figure 2.2 — (a) 24-hour alternating-block design storm; (b) 72-hour SW monsoon design storm with the 24-hour design depth on the final day. Illustrative depths only. Original drawing for this Manual. The alternating-block method follows Chow, Maidment & Mays, Applied Hydrology (1988), §14.4.
2.9.3 Other temporal patterns. Huff-type or mass-curve patterns derived from West Bengal storms may be used instead of 2.9.1 and 2.9.2 only after they are published in Annex 2D. SCS Type I, IA, II and III distributions shall not be used.
2.9.4 Large catchments. For catchments of 25–5,000 km², the CWC Flood Estimation Report time-distribution curves may be used, and a sensitivity run with 2.9.1 shall be reported.
Commentary. The alternating-block storm embeds every shorter-duration design intensity in one hyetograph. That makes it conservative and consistent across durations. The 72-hour pattern puts the most intense day last. This reproduces the West Bengal sequence: in September 1978 the heaviest falls came on 27–28 September after days of rain, and by the time they arrived the pukurs, khals and fields of the delta were full and its clay soils saturated. The same sequence fills the DVC reservoirs whose releases then govern the river tailwater, as in September 2024, and in Kolkata it fills the outfall channels whose levels limit the pumps. SCS distributions are excluded because they come from US convective and Gulf storm data and have no basis in West Bengal records.
2.10 Retention rainfall depth
2.10.1 The retention design depth is the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record, read from the zone value in Annex 2E.
2.10.2 The site must retain on site the runoff from this depth (Chapter 4). Retention earns a detention credit equal to the reduction in required detention storage found by routing with the retention in place (Clause 4.4.6). The credit is not the retained volume subtracted one-for-one.
Commentary. This follows the Kansas City Metro APWA 5600 (2025.01) Required Retention Volume concept and Georgia's 1.0-inch runoff reduction standard. Both are based on percentile storms. A percentile depth is a statistic of everyday rainfall, not an AEP value, so it is computed from the daily record rather than from the frequency curves.
2.11 Design storms for pre- and post-development comparison
2.11.1 Same storm for both scenarios. Pre- and post-development runs shall use the same design storms:
- same AEP, duration, temporal pattern and climate factor;
- same antecedent moisture condition (Clause 2.11.4).
The two runs differ only in land surface parameters and Tc.
2.11.2 Standard catchments. For each of the 50%, 10% and 1% AEP storms and each duration in Clause 2.5.2:
Q_post(T) ≤ 0.9 × Q_pre(T)
2.11.3 Flood-sensitive catchments (as listed in Chapter 4: the low-lying wards of Kolkata and its outfall-channel catchments, Howrah, the lower Damodar and Ghatal, the Sundarbans islands, and Siliguri and the Teesta towns, and any catchment notified by the authority). The mixed-frequency rule applies:
Q_post(1% AEP, 100-yr) ≤ Q_pre(10% AEP, 10-yr), and Q_post(50% AEP, 2-yr) ≤ Q_pre(50% AEP, 2-yr),
The post-development peak is checked for each duration in Clause 2.5.2. The caps are taken at the pre-development critical duration. The 10-yr cap is the largest pre-development 10-yr peak over all durations, and the 2-yr cap is the largest pre-development 2-yr peak over all durations. Each cap applies to every post-development duration.
2.11.4 Antecedent moisture. Use AMC III (wet conditions) for every design storm of June–September at a site in zone WB-Z1 (Darjeeling–Kalimpong hills) or WB-Z2 (Terai and Duars) of Annex 2A, and for every design storm of July–September elsewhere in the State, whatever its duration. Use AMC III also for every design storm of the cyclone months, May and October–November, at a site in zone WB-Z6 (Coastal belt and Sundarbans). Use AMC II (average conditions) for every other storm, including those of June outside WB-Z1 and WB-Z2.
2.11.5 Pre-development condition. Pre-development is defined in Chapter 3: greenfield, open land in good condition for the mapped hydrologic soil group. Existing impervious cover is not counted as pre-development.
Commentary. Matching each site's post-development peak to its own pre-development peak does not protect the catchment. Denver's analysis found that 100% matching at every site still produced 106% of historic peak downstream, which led to the 90% rule. The mixed-frequency rule is stricter. It caps the 100-yr post-development release at what the undeveloped site produced in a 10-yr storm. Malaysia (DID 2008: all ARIs ≤ pre-development 2-yr) is a tropical precedent for this kind of cap. AMC III for long storms reflects that SW monsoon extremes arrive after weeks of rain. In West Bengal this holds for short storms too. The deltaic clays of Kolkata, Howrah and the 24 Parganas have a high water table through the season, and the CWC design loss rates, 2.7 mm/h in subzone 1(g) and 2.4 mm/h in 2(a) (CWC, 1994; CWC, 1991), are low, as they would be on saturated clays. North Bengal is wetter and its season longer: Jalpaiguri's annual mean is 3,721 mm and Cooch Behar's 3,050 mm (IMD, 2020), and its monsoon begins in early June. The cyclones of May and October–November come with days of rain from the same system and the surge that closes the outfalls. This Manual therefore uses AMC III for every design storm of June–September in the north (zones WB-Z1 and WB-Z2), of July–September elsewhere, and of the cyclone months on the coast (zone WB-Z6), and AMC II otherwise (Clause 2.11.4). These are interim choices set by this Manual; no West Bengal study has yet validated AMC classes against observed runoff.
Illustrative scale of the mixed-frequency rule. The values below are not design values. They assume a 2 ha site in the Gangetic delta near Kolkata with 24-h depths of 200 mm (10-yr) and 350 mm (100-yr), SCS-CN runoff with Ia = 0.2S, and CN 70 pre-development and CN 92 post-development:
Table 2.3 — Illustrative scale of the mixed-frequency rule (not design values)
| Case | Runoff depth | Runoff volume (2 ha) |
|---|---|---|
| Pre-development, 10-yr 24 h | 111 mm | 2,210 m³ |
| Post-development, 100-yr 24 h | 325 mm | 6,500 m³ |
The post-development 100-yr storm generates about three times the runoff volume of the pre-development 10-yr storm. A peak-rate cap at the pre-development 10-yr level means most of the difference must be stored and released slowly, so storage of the order of 0.2 m³ per m² of site may be needed. For this reason the rule applies only in flood-sensitive catchments (Clause 2.11.3); elsewhere the 0.9 × Q_pre rule of Clause 2.11.2 applies.
2.12 Joint occurrence with tailwater
2.12.1 For outfalls under tidal or river backwater influence, the design rainfall of this chapter shall be combined with the tailwater conditions of Chapter 5 as follows. The more severe case governs.
- (a) Design rainfall (AEP as required) with a mean high water springs (MHWS) tailwater plus the sea-level allowance.
- (b) A 10% AEP (10-yr) 48-hour storm with the 1% AEP still-water level (tide plus surge) plus the sea-level allowance.
Kolkata drains away from the Hooghly: the bank of the river is a natural levee and the land slopes east, so most of the city's storm water is pumped into outfall channels that run through the East Kolkata Wetlands to the Kulti outfall on the Kultigang, a channel of the tidal Raimangal estuary (I&WD). Cases (a) and (b) are therefore run at every pumping station and lock that discharges to those channels or to the Hooghly, with the tailwater of Chapter 5: the tidal level in the Kultigang plus the hydraulic gradient of the channel for the eastern outfalls, and the Hooghly level for the river outfalls. KEIIP records that one Kolkata pumping basin stays flooded because "discharge through the outfall is partially achieved due to high water levels in the canal, particularly during tidal period" (KMC, 2015). Howrah lies lower than the Hooghly (CPHEEO), and in Howrah, Hooghly and Purba Bardhaman districts the tailwater is the Damodar, Mundeswari or Rupnarayan level under DVC release scenarios as well as the tide. At Haldia, Diamond Harbour, Digha and the Sundarbans towns the tailwater is the estuary or the sea, where the tide range reaches about 17 ft (5.2 m) at the mouth of the Hooghly (CWPRS) and the 100-year extreme sea level at Diamond Harbour is 3.79 m above mean sea level (INCOIS, 2025); levels are taken on a stated datum (chart datum, mean sea level or the Kidderpore Old Datum), as Chapter 5 requires. In North Bengal, at Siliguri and Jalpaiguri, the tailwater is the Mahananda or Teesta level, not the sea.
Commentary. On the Bengal coast the coincidence is on record. During Aila, on 25 May 2009, the surge at Sagar Island was reported as about 3.3 above the predicted level (the unit is not stated), "exacerbated by the occurrence of the new moon the day after" (I&WD); Yaas, on 26 May 2021, came at a perigean spring tide, with a surge reported at more than 2 m above the astronomical tide at Digha and in the Sundarbans (as reported); and in Kolkata the flooding of 23 September 2025 was blamed partly on a high tide in the choked canals (as reported). INCOIS puts the tidal maximum at Diamond Harbour at 2.57 m and the 100-year extreme sea level at 3.79 m above mean sea level, rising to 4.34 m (SSP2-4.5) or 4.46 m (SSP5-8.5) by 2100 (INCOIS, 2025). Mean sea level at Diamond Harbour rose by 3.73 mm a year over 1948–2015 and at Haldia by 2.62 mm a year over 1971–2023 (PSMSL), while parts of Kolkata subsided by 2.8–5.5 mm a year in 2017–2022 (Thakur et al., 2026): relative sea-level rise at a Kolkata outfall adds both. The levels of the sources are on different datums, which is why Chapter 5 requires every level to name its datum. Because rainfall and surge share a weather cause (the cyclones of the Bay of Bengal that bring the heaviest coastal rain also drive the surge, and the recent ones have struck near spring tides: Aila in May 2009, the day before a new moon, and Yaas in May 2021, at a perigean spring tide), they cannot be treated as independent. Case (b) is a simple joint-probability surrogate until a statistical joint analysis is adopted.
2.13 Submittal requirements
Every hydrologic submittal shall include a Design Rainfall Sheet (Form 2-1) stating:
- the site coordinates and zone;
- the source (Clause 2.3), version or access date, and a screenshot or export of the values extracted;
- a depth table for each AEP and duration used, before and after the fixed-interval factor, grid-to-point factor, ARF and climate factor;
- the cross-check values of Clause 2.3.3 and the floor check;
- the hyetographs used, as a table and a plot, for each design storm; and
- the AMC and pre-development definition adopted.
Figure 2.3 shows the steps of this chapter in the order in which the sheet records them.
Figure 2.3 — From design rainfall source to design storm: the steps a designer follows (source, AEPs and durations, point depth, grid-to-point and areal reduction, climate factor, temporal pattern, design storm), the clause that governs each step, what Form 2-1 records, and the separate route for the retention depth. Schematic. Original drawing for this Manual.
2.14 Review and update
2.14.1 The approving authority shall review this chapter every 10 years. It shall also review it within 2 years of any event in which recorded rainfall exceeds the 1% AEP 24-hour or 72-hour design depth at two or more approved gauges in the State.
2.14.2 Updates to NIH-DHAARA take effect for new submittals 6 months after release, unless the authority notifies otherwise.
References (chapter)
- National Institute of Hydrology, Roorkee. NIH-DHAARA: Design Hydrology and Advanced Rainfall Analysis. http://www.nihdhaara.in/
- Das, S.K. et al. (2022). Isopluvial analysis and intensity–duration–frequency curves for different cities in India. MAUSAM 73(4), 887–898. https://metnet.imd.gov.in/docs/mausamdocs/173412_F.pdf
- Central Water Commission (1994). Flood Estimation Report for Lower Ganga Plains Subzone 1(g) (revised). Design Office Report No. LG-1(g)/R-1/23/94, November 1994 (Plates 8–10, the short-duration ratio table, Annexes 4.3 and 4.4; read from the Wayback Machine capture of 12 Apr 2016 of the cwc.gov.in copy). https://cwc.gov.in/regional-flood-estimation-report
- Central Water Commission (1991). Flood Estimation Report for North Brahmaputra Subzone 2(a). Report No. NB/18/1991 (Plates 8–10, the short-duration ratio table and Table 7; read from the Wayback Machine capture of 12 Apr 2016).
- Central Water Commission (1985). Flood Estimation Report for Middle Ganga Plains Subzone 1(f). Report No. GP/10/1984, October 1985 (read only through an OCR text of the scanned copy; values not checked against the page images).
- MoHUA / CPHEEO (2019). Manual on Storm Water Drainage Systems, Part A.
- National Institute of Hydrology, Roorkee. NIH-DHAARA IDF Curve Tool (IMDAA reanalysis, 2000–2022; bias-corrected CMIP6), queried at Kolkata (Alipore), Dum Dum, Haldia, Digha, Canning, Asansol, Durgapur, Bankura, Purulia, Malda, Siliguri, Jalpaiguri, Darjeeling, Cooch Behar and Alipurduar on 6 Nov 2026. http://117.252.14.251:8080/
- India Meteorological Department. Extremes of Temperature and Rainfall for Indian Stations (up to 2012). https://imdpune.gov.in/library/public/EXTREMES%20OF%20TEMPERATURE%20and%20RAINFALL%20upto%202012.pdf
- India Meteorological Department (2025). Press release: Extremely heavy rainfall over Kolkata, 23 Sep 2025. https://internal.imd.gov.in/press_release/20250923_pr_4321.pdf
- India Meteorological Department (2020). Super Cyclonic Storm "AMPHAN" over the southeast Bay of Bengal (16th–21st May, 2020): A Report, 14 Jun 2020. https://internal.imd.gov.in/press_release/20200614_pr_840.pdf
- Guhathakurta, P., Khedikar, S., Menon, P., Prasad, A.K., Sable, S.T. & Advani, S.C. (2020). Observed Rainfall Variability and Changes over West Bengal State. Met Monograph ESSO/IMD/HS/Rainfall Variability/29(2020)/53, IMD Pune (read from a third-party copy). https://www.indiaspend.com/h-library/wbengalfinal.pdf
- ICAR-CRIDA. District Agriculture Contingency Plans, West Bengal, §1.2 (south Bengal districts). https://www.icar-crida.res.in/CCP/WB/
- Gupta, K. (2005). The drainage systems of India's cities. Waterlines 23(4), 22–24. https://web.archive.org/web/20241111031826/https://www.ircwash.org/sites/default/files/Gupta-2005-Drainage.pdf
- MoHUA / CPHEEO. Appraisal Note for Consideration of Projects under JNNURM (Storm Water Drainage): Improvement of drainage in Howrah city and its vicinity, No. Q-12045/28/10/NURM/2006-CPHEEO. https://sudawb.org/wbdma_oldversion_old/PDF/URBAN_GROVER/Improvement%20of%20drainage%20in%20Howrah%20city%20and%20its%20vici.pdf
- Kolkata Municipal Corporation for ADB (2015). Initial Environmental Examination, KEIIP Tranche 1, Sewerage and Drainage, updated and revised final report, Oct 2015. https://ewsdata.rightsindevelopment.org/files/documents/23/ADB-42266-023_TfN9hJv.pdf
- Irrigation and Waterways Department, Government of West Bengal. Kolkata Metropolis Drainage; AILA (web pages, Wayback Machine captures of 1 May 2026). https://web.archive.org/web/20260501071330/https://wbiwd.gov.in/index.php/applications/kolkata_drainage ; https://web.archive.org/web/20260501071547/https://wbiwd.gov.in/index.php/applications/aila
- Gole, C.V. & Vaidyaraman, P.P. (CWPRS). Salinity distribution and effect of fresh water flows in the Hooghly River. Coastal Engineering Proceedings (ICCE), Ch. 79. https://icce-ojs-tamu.tdl.org/icce/article/download/2492/2157/10823
- INCOIS (2025). An interim report on the projected climate change induced extreme sea levels and coastal vulnerability along the Indian coasts, ESSO-INCOIS-OMDA-TR-04(2025). https://incois.gov.in/documents/Reports/TechnicalReports/TR_ESSO-INCOIS-OMDA-TR-04(2025)_20250725114934.pdf
- Permanent Service for Mean Sea Level. Relative sea-level trends, Diamond Harbour (ID 543) and Haldia (ID 1270), table updated 19 Jan 2026. https://psmsl.org/products/trends/
- Thakur, A.K., Singh, A., Garg, R.D. & Jain, K. (2026). Spatiotemporal analysis and forecasting of ground deformation in Kolkata using PS-InSAR. ISPRS Annals XI-3-2026, 943. https://isprs-annals.copernicus.org/articles/XI-3-2026/943/2026/isprs-annals-XI-3-2026-943-2026.pdf
- Ali, H. & Mishra, V. (2018). Increase in subdaily precipitation extremes in India under 1.5 and 2.0 °C warming worlds. Geophysical Research Letters 45. https://repository.ias.ac.in/142345
- Vinnarasi, R. & Dhanya, C.T. (2022). Time-varying intensity-duration-frequency relationship through climate-informed covariates. Journal of Hydrology 604, 127178 (not read). https://doi.org/10.1016/j.jhydrol.2021.127178
- Ghate, A.S. & Timbadiya, P.V. (2023). True interval non-stationary intensity-duration-frequency curves under changing climate and effect of temporal discretisation on rainfall extremes. Journal of Hydrology 618, 129136 (not read). https://doi.org/10.1016/j.jhydrol.2023.129136
- Press reports of the DVC releases of 16–19 Sep 2024, of cyclone Yaas (May 2021) and of the Kolkata storm of 23 Sep 2025, including the KMC gauge at Garia (secondary sources).
- Chow, V.T., Maidment, D.R. & Mays, L.W. (1988). Applied Hydrology. McGraw-Hill (alternating-block method, §14.4).
- Kansas City Metro Chapter APWA (2025). Section 5600 Storm Drainage Systems and Facilities, Version 2025.01.
- Mile High Flood District (Denver). Urban Storm Drainage Criteria Manual (90% release rationale).
- Department of Irrigation and Drainage Malaysia (2008, 2012). Urban Stormwater Management Manual (MSMA).
Annexes
| Annex | Content |
|---|---|
| 2A | NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map |
| 2B | Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule |
| 2C | Grid-to-point factors |
| 2D | West Bengal temporal patterns (Huff curves) |
| 2E | Retention percentile depths by zone |
| Form 2-1 | Design Rainfall Sheet |
Commentary. Most past drainage failures in West Bengal trace to the rainfall input, not the hydraulics. West Bengal shows how. No design-intensity table or IDF relationship was found for any city in the State in research for this Manual. Kolkata's first brick sewer (1876) was designed for 6.35 mm of rain an hour, and the attempt in the 1970s to raise it to 12.7 mm an hour was not achieved (Gupta, 2005), while single hours of the city's storms reach about 100 mm (Dum Dum, 24 August 1987; Alipore, 23 September 2025). The metropolitan drainage master plan was based on a storm of "once in two months", six times a year, with 70% imperviousness, and the curve drawn for it "has been adopted by KMDA / ULBs" (CPHEEO); the curve itself was not found. The KEIIP environmental reports state no design intensity, return period or runoff coefficient (KMC, 2015). The two published sources that seem to fill the gap do not. IMD Das et al. (2022) has no panel for any West Bengal station. NIH-DHAARA's reanalysis-based 24-hour depths agree with the CWC plates near Kolkata but are about twice the plate values and the gauge records at Siliguri and Cooch Behar (Clause 2.3.6). Fixing one transparent source and method for the whole state is the main purpose of this chapter.