Draft v1.0 prepared by NEER. Not adopted by the Government of Haryana or any authority or local body, and has no legal force. About this draft

Annexes to Chapter 2Design Rainfall and Design Storms

These annexes support Chapter 2. Annexes 2A to 2E will hold the statewide rainfall tables that Chapter 2 refers to: the benchmark checks and zone map, sub-daily ratios, grid-to-point factors, temporal patterns and retention depths. Each needs analysis of NIH-DHAARA and IMD records that has not yet been done for this Manual, so each is marked "To be prepared" and gives its intended layout and the rule to use until it is published (Clause 1.11.5). Form 2-1 is a draft form for the Design Rainfall Sheet that every hydrologic submittal must include (Clause 2.13). The Manual is a draft; it is not adopted by any government or agency.


Annex 2A — NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map

Supports Clauses 2.3.1 to 2.3.5 of Chapter 2.

To be prepared. This annex will compare, at benchmark points across the State, the NIH-DHAARA design depths with frequency analyses of long IMD daily station records and of IMD gridded daily data (converted to point values with Annex 2C), for 24 hours and longer and for the AEPs of Table 2.1. It will also contain the map of rainfall zones used by Annexes 2B, 2C and 2E and by the Tier B tables of Chapter 4. It needs NIH-DHAARA values at the benchmark coordinates (NIH), IMD daily and recording-gauge station records and IMD gridded rainfall (IMD), State rain-gauge records (the tehsil and block rain gauges whose readings the district administrations report, the gauges of I&WRD, and any automatic gauges of GMDA, the Municipal Corporations and the city command centres [TBC]), and district and basin boundaries (Survey of India, I&WRD). Until it is published, design depths are taken from NIH-DHAARA under Clause 2.3.1, the cross-checks of Clause 2.3.3 are reported on Form 2-1, and the zone of a site is the one agreed with the Authority and recorded on Form 2-1.

Table 2A.1 — Benchmark comparison of design depths (layout)

Benchmark point IMD station ID Latitude, longitude Years of record Duration (h) AEP NIH-DHAARA (mm) IMD station analysis (mm) IMD gridded, point value (mm) NIH-DHAARA / IMD station Remarks
        24            
        48            
        72            

2A.1 The zone names below are the working names used in the Tier B table template of Chapter 4 (Clause 4.14.2). Their boundaries, and whether further zones are needed, are to be set by the analysis of this annex.

Table 2A.2 — Rainfall zones (layout)

Zone (working name) Extent (districts, basins) Representative stations Notes
HR-Z1 Shivalik foothills The Shivalik foothills and the piedmont below them, from Kalka–Pinjore and Morni through Panchkula, Naraingarh and Ambala to Yamunanagar–Jagadhri, Sadhaura and Kalesar, in CWC subzone 1(e) up to the zone 7 line, with the Kalka–Pinjore upland beyond it and the Morni and Kalesar hills on it (Clause 2.3.6(b)); catchments that cross a zone line take the higher zone value Ambala 42103 (daily record 1901–2012), Chandigarh 42105 (1954–2009, the reference gauge for Panchkula) District annual normals 988.0 mm at Ambala and 1,073.6 mm at Chandigarh, the highest in the State (IMD, 1901–1980). FER 50-yr 24-h about 240–262 mm (spot 262 at Chandigarh, about 250 at Ambala) and 100-yr about 240–289 mm (spot 289 at Chandigarh); 1-h ratio 0.34; the report asks for a "suitable increase" for steep foothill catchments. Records: Dadupur 444.5 mm (2 Jul 1966; name [TBC]), Chandigarh 302.2 mm (9 Jul 2023, real-time), Jagadhari 287.0 mm (2 Aug 1908), Ambala 246.2 mm (3 Aug 2004) and 224.1 mm (9 Jul 2023), Naraingarh 243.8 mm (13 Jul 1886) (IMD). NIH-DHAARA 50-yr 24-h high here (Panchkula 320, Morni 317, Yamunanagar 306 mm)
HR-Z1 Shivalik foothills: HR-A Shivalik foothills and choes Panchkula, Pinjore–Kalka, Morni, Naraingarh, Ambala, Yamunanagar–Jagadhri, Sadhaura, Bilaspur and Kalesar; boundaries [TBC] Ambala, Chandigarh A piedmont belt about 2–4 km wide of coarse sand, gravel and boulders below the Shivalik sandstones and clays (CGWB); choes (seasonal torrents) carrying boulders. The worked example of the 1(e) report, the Ghaggar at road bridge No. 2 about 7 km west of Ambala City (1,126 km², slope 5.14 m/km), reads 25.0 cm at 50 years and gives a 50-year peak of 2,706 m³/s, about 2.4 m³/s/km². Receiving waters: the Ghaggar below the Kaushalya dam, with its floodplain zone notified in Panchkula under section 45 (27 Oct 2023; 100-year flood 2,933.45 m³/s); the Tangri and the Markanda (peaks of about 38,000–52,649 cusecs reported in 2023, conflicting [TBC]); the Somb and the Pathrala; and the Yamuna at the Hathnikund barrage (design flood 22,000 m³/s; record 8,28,072 cusecs on 18 Aug 2019, as reported). CWC has no flood site in the Ghaggar basin
HR-Z2 Northern, NCR and central plains The alluvial plains of the Yamuna and the Ghaggar below the foothills, the NCR districts south to the Aravallis and the Sahibi, and the Rohtak–Jhajjar–Sonipat belt, in CWC subzone 1(e); catchments that cross a zone line take the higher zone value Karnal 42137 (1949–2012), Gurgaon 42178 (1965–2012), Rohtak 42176 (1967–2012); New Delhi/Safdarjung 42182 (from 1901) for Gurugram and Faridabad (Clause 2.3.6(d)) District annual normals about 474–696 mm (Rohtak 474.4, Faridabad 564.3, Sonepat 567.0, Gurgaon 577.8, Kurukshetra 581.8, Karnal 695.8 mm; IMD, 1901–1980). FER 50-yr 24-h about 200–240 mm and 100-yr about 200–280 mm; 1-h ratio 0.34. The September storms of 1875, 1911 and 1933 put more than 240 mm in a day on several gauges at once in the south of the zone. NIH-DHAARA 50-yr 24-h 177–262 mm, low at Gurugram (194) and Rohtak (177), above the plates at Faridabad (262)
HR-Z2 Northern, NCR and central plains: HR-B Upper Yamuna–Ghaggar plains Kurukshetra, Shahabad, Kaithal, Karnal, Panipat and Samalkha, along the GT Road; boundaries [TBC] Karnal Recent Yamuna and Ghaggar alluvium, with sodic soils in Kurukshetra, Kaithal and parts of Karnal; the deepest water tables in the State, more than 30 m below ground over 97% of Kurukshetra district in June 2023 (HWRA), and a trough along the GT Road in Panipat and Sonipat (CGWB). FER 50-yr 24-h about 200–240 mm. Records: Karnal 250.0 mm (21 Sep 1962), Panipat 254.0 mm (19 Sep 1933) (IMD). Receiving waters: the Yamuna at Karnal (CWC; danger level 249.5 m, highest flood level 250.07 m, 17 Jun 2013) and at Mawi (danger level 230.85 m, highest flood level 232.75 m, 18 Jun 2013) (as copied from CWC's list); Drain No. 2 at Panipat (6,325 cusecs, NCRPB); the Saraswati and the Ghaggar at Guhla (breaches in 2023, as reported)
HR-Z2 Northern, NCR and central plains: HR-C NCR south (Aravalli–Sahibi) Gurugram, Manesar, Sohna, Faridabad, Ballabgarh, Palwal and Nuh; boundaries [TBC] Gurgaon, with New Delhi/Safdarjung Aravalli rock and scree, about 17–23% of the mapped area of Gurugram, Faridabad and Mewat (CSSRI), over older alluvium; water tables more than 30 m deep over 51% of Gurugram district (HWRA); saline pockets. FER 50-yr 24-h about 220–240 mm, the band of Delhi; the absolute floors of Clause 2.3.6(g)(ii) apply. Records: Palwal 398.8 mm and Ballabgarh 299.7 mm (9 Sep 1875), Ferozepur Jhirka 315.0 mm (1 Sep 1884), Gurgaon 282.2 mm (14 Jul 1968) and 261.2 mm (30 Jun 1981) (IMD). Short falls: 103 mm in 90 minutes (9–10 Jul 2025) and more than 100 mm in 4 hours (1 Sep 2025) in Gurugram (as reported). Receiving waters: Gurugram's Legs I–III (the Badshahpur drain; 541, 1,305 and 3,702 cusecs on DTCP's drawing of 2012) to the Najafgarh drain; the Budhiya nala and the Gaunchi drain to the Yamuna at Faridabad and Palwal
HR-Z2 Northern, NCR and central plains: HR-D Rohtak–Jhajjar–Sonipat waterlogged belt Rohtak, Jhajjar, Bahadurgarh, Sonipat, Gohana, Beri and Sampla, and the east of Jind district; boundaries [TBC] Rohtak Saline-sodic soils and marginal-saline groundwater; the water table within 3 m of the surface over about 50% of Rohtak and 43% of Jhajjar district in June 2023, and the waterlogged area larger by about 30% in October (HWRA); every block of Rohtak and Jhajjar "safe" (CGWB, 2024). FER 50-yr 24-h about 200–220 mm. Records: Rohtak 484.1 mm, Jhajjar 325.1 mm and Beri 279.4 mm (19 Sep 1933), Rohtak 297.9 mm (30 Jun 1981), Sampla 259.1 mm (9 Sep 1875) (IMD). Receiving waters: Outfall Drain No. 8 to the Dhansa regulator and the Najafgarh drain (capacity 4,000 cusecs; 5,000 cusecs in 2022, I&WRD); Drain No. 6 at Sonipat, diverted to the Narela drain in Delhi; the Sahibi at Dadri (highest flood level 214.98 m, 26 Aug 2008, CWC list)
HR-Z3 Dry south-west The dry plains and dunes of the centre and south-west, and the Aravalli outliers of the south, in CWC subzone 1(e) near its line with subzone 1(a); catchments that cross a zone line take the higher zone value Hissar 42131 (1914–2012), Narnaul 42177 (1966–2012); Bhiwani 42350 (1992–2012) as a check only District annual normals about 325–520 mm (Sirsa 325.3, Hisar 396.5, Bhiwani 425.1, Mahendragarh 518.3 mm; IMD, 1901–1980). FER 50-yr 24-h about 160–220 mm and 100-yr about 180–240 mm; 1-h ratio 0.34. NIH-DHAARA 50-yr 24-h low here (Narnaul 113, Sirsa 116, Hisar 139, Bhiwani 154, Rewari 162 mm)
HR-Z3 Dry south-west: HR-E Central and south-west dry plains and dunes Hisar, Hansi, Bhiwani, Charkhi Dadri, Sirsa, Fatehabad, Tohana and Ellenabad, and the west of Jind district; boundaries [TBC] Hissar Sand dunes and sandy and loamy-sand soils, with calcareous layers and saline groundwater (CGWB); water tables mixed, within 3 m over about 14% of Hisar district and deeper than 30 m over about half of Fatehabad (HWRA). FER 50-yr 24-h about 200–220 mm at Hisar, 180–200 mm at Bhiwani and 160–180 mm at Sirsa and Fatehabad. Records: Hissar 346.7 mm (16 Aug 1926), Bhiwani 246.6 mm (4 Sep 1995), Hansi 228.6 mm (1960) (IMD). Receiving waters: the Ghaggar at Chandpur and the Ottu weir (about 38,400 cusecs on 21 Jul 2023, as reported), with breaches in Fatehabad and Sirsa in 2023; inland depressions
HR-Z3 Dry south-west: HR-F Ahirwal Aravalli south Rewari, Dharuhera, Kosli, Narnaul and Mahendragarh; boundaries [TBC] Narnaul Aravalli outliers and sandy plains; deep water tables, more than 30 m over 85% of Mahendragarh district (HWRA), and 76.50 m at Mandola after the 2021 monsoon (CGWB). FER 50-yr 24-h about 180–200 mm at Narnaul and about 200 mm at Rewari, inside a closed contour over the Sahibi. Records: Narnaul 237.4 mm (12 Aug 1972) (IMD). Receiving waters: the Sahibi at the Masani barrage (crest 240.00 m, bay walls 242.20 m, I&WRD; highest flood level 242.58 m, 2 Sep 1978, CWC list); the Krishnavati and the Dohan; flash floods from Rajasthan, as in 1977

Annex 2B — Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule

Supports Clauses 2.6.1 to 2.6.4 of Chapter 2.

To be prepared. This annex will tabulate, for each zone of Annex 2A, the ratios of the t-hour to the 24-hour design depth from NIH-DHAARA, which are derived from hourly records, against the ratios implied by IMD Das et al. (2022) and by the one-third rule. It needs NIH-DHAARA depths for each duration at representative points in each zone (NIH), IMD recording-gauge data and the IDF values of Das et al. (2022) (IMD). Until it is published, sub-daily depths are read directly from NIH-DHAARA or an approved station IDF (Clause 2.6.1). Where only daily depths are available, the ratios used are those agreed with the Authority, which in Haryana are those of Clause 2.3.6: the CWC Flood Estimation Report ratios for subzone 1(e) in Table 2B.1, raised at 1 and 3 hours to the floors of Clause 2.3.6(g) for the 10-yr and rarer storms (Clause 2.6.2), and are recorded on Form 2-1. The one-third rule is not used (Clause 2.6.4).

2B.1 The first row of Table 2B.1 gives the ratios of the one-third rule P(t) = P(24)·(t/24)^(1/3), for comparison only. The 1, 3, 6 and 12 h values are those stated in the commentary to Clause 2.6; the 2 h value is computed from the same formula. The rule shall not be used for design unless this annex confirms it for the zone concerned (Clause 2.6.4).

Table 2B.1 — Ratios P(t)/P(24h) by zone (layout)

Zone Source 1 h 2 h 3 h 6 h 12 h 24 h
All (reference only, not for design) One-third rule 0.35 0.44 0.50 0.63 0.79 1.00
HR-Z1, HR-Z2 and HR-Z3 (all sub-areas) CWC FER 1(e), 50-yr (interim design ratios, Clause 2.3.6(f)) 0.340 0.475 0.560 0.680 0.840 1.00
HR-Z1, HR-Z2 and HR-Z3 (all sub-areas) Ratio floor of Clause 2.3.6(g)(i), 10–100 yr 0.35   0.57     1.00
HR-Z2 (HR-C) Floors of Clause 2.3.6(g)(ii) at 50-yr, as ratios to the 220–240 mm of the plates at Gurugram and Faridabad (comparison only; the floors are depths) 0.44–0.48   0.63–0.68     1.00
HR-Z2 (HR-C): Gurugram NIH-DHAARA, 50-yr, Gurugram cell (comparison only; 3- and 6-hour values not queried) 0.30 0.42     0.82 1.00
HR-Z1 (HR-A): Panchkula NIH-DHAARA, 50-yr, Panchkula cell (comparison only; 3- and 6-hour values not queried) 0.28 0.45     0.88 1.00
HR-Z3 (HR-E): Hisar NIH-DHAARA, 50-yr, Hisar cell (comparison only; 3- and 6-hour values not queried) 0.33 0.45     0.85 1.00

2B.2 Depths from fixed observation windows are converted to true-interval depths with the factors of Clause 2.6.3, repeated in Table 2B.2. They are the standard WMO (Hershfield) values and are not provisional.

Table 2B.2 — Fixed-interval adjustment factors (Clause 2.6.3)

Number of fixed observation intervals in the duration Factor
1 1.13
2 1.04
3–4 1.02

Annex 2C — Grid-to-point factors

Supports Clauses 2.7.1 and 2.7.4 of Chapter 2.

To be prepared. This annex will give the factors that convert grid-average design depths (for example from 0.25° cells) to point depths, by zone, duration and AEP. It needs paired frequency analyses of IMD gridded rainfall and of the IMD and State gauges inside each cell (IMD, I&WRD and the tehsil rain gauges whose readings the State reports [TBC]), the benchmark points of Annex 2A, and a stated method for deriving the factors. Until it is published, design depths are taken as point values from NIH-DHAARA or an approved station IDF (Clauses 2.3.1 and 2.3.2). Grid-average values are not used as design depths unless a conversion agreed with the Authority is recorded on Form 2-1 (Clause 1.11.5).

2C.1 The commentary to Clause 2.7 shows why the factors matter, and in Haryana the reanalysis cells err in both directions. In the south and west they err low: the IMDAA cell of NIH-DHAARA (about 12 km) at Hisar gives a 50-year 24-hour depth of about 139 mm and a 100-year depth of about 156 mm, against a CWC plate value of about 200–220 mm and the 346.7 mm recorded at the Hissar observatory on 16 August 1926; at Rohtak about 177 mm, against the 297.9 mm of 30 June 1981 and the 484.1 mm of 19 September 1933; at Gurugram about 194 mm, against the 282.2 mm of 14 July 1968; and at Narnaul and Sirsa about 113 and 116 mm, against plate values of about 160–200 mm. In the Shivalik foothills they err high: about 320 mm at Panchkula, 317 mm at Morni and 306 mm at Yamunanagar, against about 240–262 mm on the plates. The cells' 50-year 1-hour depths, about 38–91 mm, are 0.25–0.36 of their 24-hour depths, and at Gurugram 58.0 mm (NIH-DHAARA, queried 7 Nov 2026; IMD; CWC). Values of this kind are grid-average values and need these factors before any use as point depths; under Clause 2.3.6 they are not used as design depths in Haryana until this annex and Annex 2A are published.

Table 2C.1 — Grid-to-point factors (layout)

Zone Grid product and cell size Duration (h) AEP Factor (point / grid) Stations used Years of record
    24        
    48        
    72        

Annex 2D — Haryana temporal patterns (Huff curves)

Supports Clauses 2.9.3 and 2.9.4 of Chapter 2, and Clause 11.7.3 of Chapter 11.

To be prepared. This annex will give dimensionless time-distribution (mass) curves of Haryana storms, in the form introduced by Huff (1967), by zone, storm-duration class and quartile, at stated probability levels. It needs storm hyetographs from recording gauges and automatic weather stations (IMD, its automatic weather stations and automatic rain gauges in the State, under the Meteorological Centre Chandigarh, and any recording gauges of I&WRD, GMDA and the city command centres [TBC]), separated into independent storms by a stated rule, and the storms of 9 September 1875 at Palwal, Ballabgarh and Gurgaon, 19 September 1933 at Rohtak, Jhajjar and Panipat, 30 June 1981 at Rohtak and Gurgaon and 9 July 2023 at Chandigarh and Ambala, and the Gurugram bursts of 9–10 July 2025 and 1 September 2025 among them. Until it is published, design storms use the alternating-block pattern of Clause 2.9.1 and the 48- and 72-hour pattern of Clause 2.9.2; for catchments of 25–5,000 km², the CWC Flood Estimation Report curves may be used with a sensitivity run under Clause 2.9.1 (Clause 2.9.4). SCS Type distributions are not used (Clause 2.9.3). For the disaggregation of daily records in continuous simulation (Clause 11.7.3), the method is agreed with the Authority and recorded (Clause 1.11.5).

Table 2D.1 — Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)

Fraction of storm time 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
10% probability curve 0                   1.0
50% probability curve 0                   1.0
90% probability curve 0                   1.0

2D.1 Each table shall state the zone, the duration class, the quartile (the quarter of the storm in which most rain fell), the number of storms analysed and the period of record.

Reference: Huff, F.A. (1967). Time distribution of rainfall in heavy storms. Water Resources Research 3(4), 1007–1019.


Annex 2E — Retention percentile depths by zone

Supports Clauses 2.8.3 and 2.10.1 to 2.10.2 of Chapter 2, Clause 4.4 of Chapter 4 and Chapter 8.

To be prepared. This annex will give, for each zone of Annex 2A, the retention design depth P_R: the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record (Clause 2.10.1). It needs long daily records at stations in each zone (IMD, I&WRD and the tehsil rain gauges whose readings the State reports [TBC]) and IMD gridded data with the factors of Annex 2C where stations are sparse. Until it is published, P_R is computed by the definition of Clause 2.10.1 from the long-term daily record of a station agreed with the Authority, by the steps in 2E.1, and recorded on Form 2-1 (Clause 1.11.5).

2E.1 Computing P_R from a daily record.

  1. Take the daily (24-hour) rainfall series of the station for its full record.
  2. Keep only the days with rain of 2.5 mm or more (wet days).
  3. Rank the wet-day depths and take the depth not exceeded on 90% of them (the 90th percentile).
  4. Do not apply the climate factor (Clause 2.8.3) or the fixed-interval factor; P_R is a statistic of everyday rainfall, not an AEP design depth.
  5. Record the station, the period of record, the number of wet days and P_R on Form 2-1.

Table 2E.1 — Retention depth P_R by zone (layout)

Zone Stations or grid cells used Period of record Number of wet days (≥ 2.5 mm) P_R, 90th percentile (mm) Issued on
HR-Z1 Shivalik foothills          
HR-Z2 Northern, NCR and central plains          
HR-Z3 Dry south-west          

Form 2-1 — Design Rainfall Sheet

Supports Clauses 2.3 to 2.13 of Chapter 2, and Clause 10.4.1(d) of Chapter 10.

Draft form — Haryana Stormwater Design Manual, Draft v1.0. One sheet for each hydrologic submittal. The steps follow Figure 2.3 of Chapter 2.

Table 2F.1 — Form 2-1: site, source and storms

No. Item (clause) Entry
A. Site (Clause 2.13, item 1)
A1 Project and site ______
A2 Site coordinates (latitude, longitude, decimal degrees) ______
A3 Rainfall zone (Annex 2A, or as agreed with the Authority) ______
A4 Contributing catchment area (km²) (Clause 2.7) ______
A5 Design life: more than 25 years / temporary works, 5 years or less (Clause 2.8.2) ______
A6 Outfall under tidal or river backwater influence: Yes / No (Clauses 2.5.3, 2.12) ______
B. Source (Clauses 2.3, 2.3.5; item 2)
B1 NIH-DHAARA: version or access date ______
B2 Coordinates queried ______
B3 Screenshot or export of the values extracted attached: reference ______
B4 Station IDF used (Clause 2.3.2): No / Yes — station, ID, distance from site (km) ______
B5 Station IDF: years of recording-gauge data (30 or more); published or approved by ______
B6 Station IDF: change of terrain or coastal exposure between gauge and site: None / describe ______
C. AEPs and durations (Clauses 2.4, 2.5)
C1 Elements designed and their AEPs (Table 2.1) ______
C2 Conveyance: Tc and design duration (not less than 10 min) (Clause 2.5.1) ______
C3 Storage: durations checked from {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48 and 72 h included (Clause 2.5.2) ______
C4 Critical duration found for each storage element ______
D. Conversions
D1 Sub-daily depths: read directly / from Annex 2B ratios / from ratios agreed with the Authority (Clauses 2.6.1, 2.6.2) ______
D2 Fixed-interval factor applied: none (true-interval source) / 1.13 / 1.04 / 1.02 (Clause 2.6.3) ______
D3 Grid-to-point factor: not needed (point source) / Annex 2C / agreed value (Clause 2.7.1) ______
D4 ARF: 1.0 (10 km² or less; single-site storage) / CWC curve / interpolated (Clauses 2.7.2–2.7.4) ______
D5 Climate factor: 1.20 (≤ 6 h) and 1.10 (> 6–72 h) / 1.0 temporary works / projected depths under Clause 2.8.4 ______
E. Cross-checks (Clause 2.3.3; item 4)
E1 IMD Das et al. (2022) values for 1–24 h: reported in Table 2F.2 ______
E2 CWC subzone 1(e) 24-hour point value, catchments of 25–5,000 km²: subzone used ______
E3 CWC floor governs for any AEP: No / Yes — AEPs ______
F. Retention depth (Clause 2.10)
F1 P_R (mm) and source: Annex 2E zone value / computed under Annex 2E, 2E.1 — station and period ______
F2 No climate factor applied to P_R (Clause 2.8.3): confirmed ______
G. Design storms (Clauses 2.9, 2.11, 2.12; items 5 and 6)
G1 Storms up to 24 h: alternating block, peak at 50%; time step (≤ Tc/3 and ≤ 15 min) ______
G2 48 and 72 h storms: built under Clause 2.9.2 (Table 2F.3) ______
G3 Other pattern used: none / Annex 2D / CWC FER with sensitivity run (Clauses 2.9.3, 2.9.4) ______
G4 Hyetographs attached as a table and a plot for each design storm: reference ______
G5 AMC: III for every design storm of 1 July–15 September in HR-A and HR-D and on river floodplains, and of July–August in HR-B and HR-C, whatever its duration; at any other site or time, III for a storm that follows or contains a 5-day total of more than 53 mm; II otherwise (Clause 2.11.4) ______
G6 Pre-development condition: greenfield, open land in good condition for the mapped HSG (Clause 2.11.5) ______
G7 Release criterion: standard, Q_post ≤ 0.9 × Q_pre (Clause 2.11.2) / flood-sensitive, mixed-frequency rule (Clause 2.11.3) ______
G8 Tailwater joint cases run (Clause 2.12): case (a) MHWS + sea-level allowance; case (b) 10% AEP 48 h storm with 1% AEP still-water level + sea-level allowance; governing case ______
H. Prepared by
H1 I confirm that the values above are those extracted and used in the submittal. Name, registration number, signature, date ______

Design depth = source depth × fixed-interval factor × grid-to-point factor × ARF × climate factor. Where the design depth is lower than the CWC floor for the same AEP, the floor is adopted (Clause 2.3.3).

Table 2F.2 — Form 2-1: depth table (Clause 2.13, item 3)

AEP (T-yr) Duration Source depth (mm) Fixed-interval factor Grid-to-point factor ARF Climate factor Design depth (mm) IMD Das et al. (2022) (mm) CWC floor (mm) Adopted depth (mm)
                     
                     
                     
                     

Table 2F.3 — Form 2-1: 48- and 72-hour storm construction (Clause 2.9.2)

AEP (T-yr) Duration (h) Total design depth (mm) 24 h design depth, final 24 h (mm) Remainder (mm) Hours before the final 24 h Uniform intensity before the final 24 h (mm/h)
  48       24  
  72       48