Draft v1.0 prepared by NEER. Not adopted by the Government of Odisha, and has no legal force. About this draft

Annexes to Chapter 3Hydrologic Methods

These annexes support Chapter 3. Annex 3C sets out benchmark test problems for software acceptance, and Forms 3-1 and 3-2 are the submittal forms required by Clause 3.17. Annexes 3A, 3B, 3D and 3E need survey, gauging or published report data that this draft does not yet contain; each gives the intended layout and the interim rule of Chapter 3 that applies until it is published. The forms are draft forms and have no statutory status.


Annex 3A — Odisha soil series to HSG lookup; seasonal high water table map

Supports Clauses 3.7 and 3.10 of Chapter 3.

To be prepared. This annex will contain (a) a lookup from each soil series mapped in Odisha to its hydrologic soil group (HSG), in both the drained and the undrained state, and (b) a map of the depth to the seasonal high groundwater table in the south-west monsoon (June–September). It needs NBSS&LUP and Odisha University of Agriculture and Technology (OUAT) series maps with their scales, measured saturated hydraulic conductivity and depth to an impermeable layer for each series, and observation-well records from the Central Ground Water Board and the GWS&I, supplemented by piezometers in the deltaic alluvium of the Mahanadi, Brahmani and Baitarani (Cuttack, Kendrapara, Jagatsinghpur, inner Puri and Bhadrak), the saline marsh of the coastal tract, the coastal dune sands of Puri, Konark, Gopalpur and Paradip, the margins of Chilika and of the tidal rivers and creeks, and the lowlands along the Gangua nala and the Daya below Bhubaneswar. Until it is published, use the interim rules of Chapter 3: assign HSG from measured saturated hydraulic conductivity and depth to an impermeable layer or water table by the criteria of NEH Part 630, Ch. 7 (Clause 3.7.2); verify it by site infiltration tests wherever retention relies on infiltration (Clause 3.7.3); take the seasonal high water table from site piezometers, trial pits or the nearest observation well (Clause 3.10.2); and assign HSG D wherever that level is within 0.6 m of the ground surface (Clause 3.10.1).

Table 3A.1 — Soil series to HSG lookup (layout)

Soil series District(s) Taxonomic class Surface texture Saturated hydraulic conductivity (mm/h) Depth to impermeable layer (m) HSG, drained HSG, undrained Source map and scale
                 
                 
                 

Table 3A.2 — Seasonal high water table, by mapping unit (layout)

Mapping unit or grid cell Observation wells used Years of June–September record Highest June–September level below ground (m) Within 0.6 m of ground (Clause 3.10.1)? Data source
           
           

Annex 3B — Odisha CN calibration and supplementary land covers (paddy, gherries, mangroves, saline marsh)

Supports Clauses 3.8 and 3.15 of Chapter 3.

To be prepared. This annex will contain (a) curve numbers calibrated against observed rainfall and runoff in Odisha catchments, compared with the TR-55 values of Table 3.5, and (b) curve numbers for land covers that Table 3.5 does not list: bunded paddy fields of the deltas and the plains (ponded and fallow), the prawn gherries and other embanked aquaculture ponds on the margins of Chilika and Bhitarkanika and in the coastal districts, the mangrove forest of Bhitarkanika and the other estuaries, and the saline marsh, swamps and tidal flats of the coastal tract. It needs paired rainfall–runoff records for small gauged catchments of known cover and soil, from DoWR gauging sites, agricultural research stations and tank gauges, analysed by event and by antecedent moisture. Until it is published: the pre-development reference stays open space in good condition for every site (Clause 3.3.2), so these covers do not enter the pre-development run; for off-site existing conditions, use the nearest Table 3.5 or TR-55 cover row, including the cultivated rows (Clause 3.8.3(c)), and state the row chosen and the reason on Form 3-1; land under standing water at the start of the design storm is modelled as water surface with no losses (Table 3.5; Clause 3.10.4(b)). Any departure from these defaults requires calibration under Clause 3.15 (Clause 3.15.1(d)).

Table 3B.1 — Supplementary land covers, AMC II (layout)

Cover type HSG A HSG B HSG C HSG D Ia ratio Basis (catchments, events, years)
Paddy, bunded, ponded (deltas and plains)            
Paddy, bunded, fallow between seasons            
Gherri or other embanked aquaculture pond (margins of Chilika and Bhitarkanika; coastal districts), embankments and margins            
Mangrove forest and tidal mudflat (Bhitarkanika and the other estuaries)            
Saline marsh, swamp and tidal flat (coastal tract of Balasore, Bhadrak, Kendrapara, Jagatsinghpur and Puri)            
Other (state)            

Table 3B.2 — CN calibration catchments (layout)

Catchment District Area (km²) Dominant HSG and cover Events used Table 3.5 CN Calibrated CN Calibrated ÷ Table 3.5
               
               

Annex 3C — Benchmark test problems for software acceptance

Supports Clauses 3.5, 3.6, 3.8, 3.9, 3.11, 3.12 and 3.16 of Chapter 3.

Purpose. Software not listed in Clause 3.16.1 shall reproduce the results of the five problems below (Clause 3.16.3). Each problem is fully specified and uses only the methods and tables of Chapter 3, so every answer can be checked by hand. The acceptance tolerance is ±5% on each tabulated result, the equivalence threshold of Clause 3.16.2; for closed-form results (Problems 3C-1 to 3C-4), software should agree to the rounding shown. The submittal shall report the software result next to each answer below.

Illustrative — not design values. The inputs (areas, intensities, rainfall depths, slopes and the basin) are chosen for testing only. They are not design data for any site.

Problem 3C-1 — Rational Method peak (Clause 3.5)

Inputs. A 2.0 ha catchment draining to one inlet: 1.2 ha concrete paving and roofs, C = 0.90 (Table 3.2, upper half of 0.80–0.95); 0.8 ha lawns on sandy soil, average slope, C = 0.15 (Table 3.2, upper half of 0.10–0.15). Design AEP 1% (100-yr). Rainfall intensity at Tc, including the climate factor: i = 120 mm/h.

Part (b): a separate 0.5 ha fully paved catchment, C = 0.90, design AEP 1%, i = 150 mm/h.

Table 3C.1 — Problem 3C-1 solution

Step Calculation Result
Composite C (Clause 3.5.4) (1.2 × 0.90 + 0.8 × 0.15) / 2.0 0.60
Frequency factor (Table 3.3) 1% AEP Cf = 1.25
C · Cf (≤ 1.0) 0.60 × 1.25 0.75
Peak flow (Clause 3.5.1) 0.75 × 120 × 2.0 / 360 Q = 0.500 m³/s
Part (b): C · Cf 0.90 × 1.25 = 1.125, capped at 1.0 (Clause 3.5.3) 1.00
Part (b): peak flow 1.00 × 150 × 0.5 / 360 Q = 0.208 m³/s

Problem 3C-2 — Time of concentration by the segment method (Clause 3.6)

Inputs. Pre-development flow path: sheet flow over greenfield, n = 0.15 (Clause 3.6.3), L = 30 m, S = 0.01; P2 (50% AEP 24-hour rainfall, no climate factor) = 80 mm. Shallow concentrated flow, unpaved, L = 200 m, S = 0.01. Channel flow, L = 400 m, bank-full velocity V = 1.0 m/s (given).

Table 3C.2 — Problem 3C-2 solution

Segment Calculation Travel time
Sheet flow (Clause 3.6.2(a)) 0.091 × (0.15 × 30)^0.8 / (80^0.5 × 0.01^0.4) = 0.2138 h 12.83 min
Shallow concentrated (Clause 3.6.2(c)) V = 4.918 × 0.01^0.5 = 0.4918 m/s; 200 / (3,600 × 0.4918) = 0.1130 h 6.78 min
Channel (Clause 3.6.2(d)) 400 / (3,600 × 1.0) = 0.1111 h 6.67 min
Tc (Clause 3.6.1; ≥ 10 min) 12.83 + 6.78 + 6.67 26.27 min
Lag (Clause 3.6.5) 0.6 × 26.27 15.76 min

Problem 3C-3 — SCS-CN runoff depth, AMC and Ia sensitivity (Clause 3.8)

Inputs. Pre-development reference on HSG C: CN = 74 at AMC II (Table 3.5), all pervious. Cumulative rainfall P = 100 mm; second case P = 25 mm.

Table 3C.3 — Problem 3C-3 solution

Case S (mm) Ia (mm) Runoff Q (mm), P = 100 mm Runoff Q (mm), P = 25 mm
(a) AMC II, Ia = 0.2S: S = 25,400 / 74 − 254 89.24 17.85 39.38 0.53
(b) AMC III, Ia = 0.2S: CN(III) = 23 × 74 / (10 + 0.13 × 74) = 86.75 38.80 7.76 64.93 —
(c) AMC II, Ia = 0.05S: S0.05 = 25.4 × 1.33 × (89.24 / 25.4)^1.15 143.31 7.17 36.49 1.97

Runoff is Q = (P − Ia)² / (P − Ia + S). Case (c) gives less runoff than case (a) at 100 mm but more at 25 mm, as Clause 3.8.5 and Figure 3.3 describe.

Problem 3C-4 — Separate vs composite impervious representation, and SCS unit hydrograph peak (Clauses 3.9 and 3.11.2)

Inputs, part (a). A site that is 50% directly connected impervious (CN 98) and 50% open space on HSG B (CNp = 61), AMC II, Ia = 0.2S, P = 25 mm.

Inputs, part (b). A sub-area of A = 2.5 km² with Tc = 1.0 h and computation interval Δt = 0.1 h.

Table 3C.4 — Problem 3C-4 solution

Step Calculation Result
(a) Impervious half (Clause 3.9.2) S = 5.18 mm, Ia = 1.04 mm; Q = 23.96² / (23.96 + 5.18) 19.70 mm
(a) Pervious half S = 162.39 mm, Ia = 32.48 mm > P 0 mm
(a) Area-weighted runoff, separate sub-areas 0.5 × 19.70 + 0.5 × 0 9.85 mm
(a) Composite CN (Clause 3.9.4) 61 + 0.50 × (98 − 61) 79.5
(a) Runoff with composite CN S = 65.50 mm, Ia = 13.10 mm; Q = 11.90² / (11.90 + 65.50) 1.83 mm
(b) Interval check (Clause 3.11.3(a)) 0.133 × 1.0 = 0.133 h ≥ Δt = 0.1 h satisfied
(b) Lag and time to peak (Clause 3.11.2) tL = 0.6 × 1.0 = 0.60 h; tp = 0.1 / 2 + 0.60 tp = 0.65 h
(b) Unit hydrograph peak, Q = 1 mm 0.208 × 2.5 × 1 / 0.65 qp = 0.800 m³/s per mm

Part (a) reproduces the comparison in the commentary to Clause 3.9 (about 9.9 mm vs 1.8 mm).

Problem 3C-5 — Level-pool (modified Puls) storage routing (Clause 3.12.1)

Inputs. A detention basin with vertical sides and plan area 500 m², with the stage–storage–discharge relationship of Table 3C.5. Triangular inflow hydrograph: 0 at t = 0, rising linearly to 0.50 m³/s at t = 30 min, falling linearly to 0 at t = 90 min. Basin empty at t = 0. Routing interval Δt = 10 min (600 s). No tailwater.

Table 3C.5 — Problem 3C-5 stage–storage–discharge relationship

Stage (m) Storage S (m³) Outflow O (m³/s)
0.0 0 0.00
0.5 250 0.05
1.0 500 0.10
1.5 750 0.15
2.0 1,000 0.20
2.5 1,250 0.25

Method. The storage-indication equation is (I1 + I2) + (2S1/Δt − O1) = (2S2/Δt + O2). The table gives O = S / 5,000 (S in m³, O in m³/s), so 2S/Δt + O = 17.667 O and 2S/Δt − O = 15.667 O, and each step is O2 = [(I1 + I2) + 15.667 O1] / 17.667. Software interpolating linearly in Table 3C.5 shall give the same result.

Table 3C.6 — Problem 3C-5 routed outflow

Time (min) Inflow I (m³/s) Outflow O (m³/s) Storage (m³) Stage (m)
0 0.0000 0.0000 0.0 0.000
10 0.1667 0.0094 47.2 0.094
20 0.3333 0.0367 183.3 0.367
30 0.5000 0.0797 398.4 0.797
40 0.4167 0.1226 612.8 1.226
50 0.3333 0.1511 755.7 1.511
60 0.2500 0.1670 835.2 1.670
70 0.1667 0.1717 858.6 1.717
80 0.0833 0.1664 832.1 1.664
90 0.0000 0.1523 761.5 1.523
120 0.0000 0.1062 531.1 1.062
180 0.0000 0.0517 258.3 0.517

Results. Peak outflow 0.172 m³/s at 70 min; peak storage 859 m³; peak stage 1.72 m. The inflow peak of 0.50 m³/s is reduced to 34% of its value.

Table 3C.7 — Benchmark results to be reported by the applicant

Problem Result Benchmark Software result Difference (%) Within ±5%?
3C-1 Q, main case (m³/s) 0.500      
3C-1 Q, part (b) (m³/s) 0.208      
3C-2 Tc (min) 26.27      
3C-3 Q, case (a), P = 100 mm (mm) 39.38      
3C-3 Q, case (b), P = 100 mm (mm) 64.93      
3C-3 Q, case (c), P = 100 mm (mm) 36.49      
3C-3 Q, case (c), P = 25 mm (mm) 1.97      
3C-4 Runoff, separate sub-areas (mm) 9.85      
3C-4 Runoff, composite CN (mm) 1.83      
3C-4 qp (m³/s per mm) 0.800      
3C-5 Peak outflow (m³/s) 0.172      
3C-5 Peak storage (m³) 859      

Annex 3D — Peak rate factor study for flat coastal land

Supports Clauses 3.11.5 and 3.15 of Chapter 3.

To be prepared. This annex will contain peak rate factors calibrated for unchannelled, flat coastal-plain and deltaic land in Odisha, such as the embanked tracts of the Mahanadi, Brahmani and Baitarani deltas in Kendrapara and Jagatsinghpur, the saline marsh behind the dunes of the coast, the plain of Puri between the dune ridge and the Sar lake, and the flat land on the margins of Chilika, with the limits of slope, drainage density and land cover within which each factor may be used. It needs observed rainfall and flow or water-level records for small, flat, undrained catchments (DoWR river gauges and the gauges at its sluices, the IMD and OSDMA automatic rain gauges, and the records of the drainage pumping stations of BMC and CMC), catchment geometry from survey or a DEM, and calibration of the SCS unit hydrograph peak to those events under Clause 3.15. Until it is published, use the standard factor 484 (PRF′ = 0.208) for all land (Clause 3.11.5): a lower factor may be used only after the authority adopts calibrated values in this annex (Clause 3.11.5(c)), and then only for land that stays unchannelled, in the same way in both the pre- and post-development runs (Clause 3.11.5(a) and (b)).

Table 3D.1 — Calibrated peak rate factors (layout)

Catchment Area (km²) Mean slope (m/m) Drainage condition Events used Calibrated PRF (US customary) PRF′ (SI) Range of applicability
               
               

Annex 3E — CWC SUH parameters for subzones 1(g), 3(d), 3(f), 3(g) and 4(a), with worked example

Supports Clauses 3.4.3 and 3.11.4 of Chapter 3.

To be prepared. This annex will tabulate, for CWC subzones 1(g) (Lower Ganga Plains), 3(d) (Mahanadi), 3(f) (Lower Godavari), 3(g) (Indravati) and 4(a) (Upper Eastern Coast), the regression relationships for the synthetic unit hydrograph parameters, the design storm duration, loss rate, base flow, areal reduction and time distribution, each with its reference to the Flood Estimation Report, and a worked example for one catchment. It needs the five CWC Flood Estimation Reports that cover Odisha: the Mahanadi subzone 3(d) (revised, Design Office Report M-3(d)/R-3/25/1996, February 1997), which covers the Mahanadi, Brahmani and Baitarani basins and most of the State, including Cuttack, Bhubaneswar, Puri, Paradip, Sambalpur and Rourkela; the combined report for the Upper, Lower and South Eastern Coast subzones 4(a), 4(b) and 4(c) (EC(U,L&S)/14/1986, January 1987), whose subzone 4(a) covers the Rushikulya, Bahuda and Vamsadhara basins and the basin of Chilika, including Berhampur and Gopalpur; the Lower Ganga Plains subzone 1(g) (revised, LG-1(g)/R-1/23/94, November 1994), which covers the Subarnarekha and Budhabalanga basins of Balasore and Mayurbhanj; the Indravati subzone 3(g) (I/21/1992), which covers Nabarangpur and the Indravati side of Koraput and Kalahandi; and the Lower Godavari subzone 3(f) (revised, LG-3(f)/R-2/24/95, August 1995), which covers the Sabari (Kolab) and Sileru basins of Koraput and Malkangiri and whose annexes and plates were missing from the copy read for this Manual [TBC]; with the subzone boundaries within Odisha, including those that pass through Bhubaneswar, Balasore and the Koraput–Jeypore plateau, to be confirmed on the reports' index maps [TBC], transcribed and checked against the published reports, and a catchment with physiographic parameters measured from survey or a DEM. Until it is published, take all SUH inputs directly from the applicable Flood Estimation Report (Clause 3.11.4(a)), apply the 24-hour design rainfall of Clauses 2.3.3(b) and 2.7.3 with the climate factor of Clause 2.8 (Clause 3.11.4(b)), report the SUH result alongside the HEC-HMS or SWMM result for the existing natural condition (Clause 3.11.4(c)), and, where the hydrograph model gives a lower 1% AEP peak, either justify it by calibration under Clause 3.15 or adopt the SUH peak (Clause 3.11.4(d)).

Table 3E.1 — SUH relationships by subzone (layout)

Parameter Symbol Unit Subzone 3(d) relationship Subzone 4(a) relationship (one set for subzones 4(a) to 4(c)) Subzone 3(g) relationship (unit hydrograph relationships by optical character recognition only) [TBC]
Time from centre of unit rainfall to peak tp h tp = 1.757 (L·Lc/√S)^0.261 tp = 0.376 (L·Lc/√S)^0.434 tp = 0.353 (L·Lc/√S)^0.45
Peak discharge per unit area qp m³/s per km² qp = 1.260 tp^−0.725 qp = 1.215 tp^−0.691 qp = 1.968 tp^−0.842
Width of UH at 50% of peak W50 h W50 = 1.974 qp^−1.104 W50 = 2.211 qp^−1.07 W50 = 2.30 qp^−1.018
Width of UH at 75% of peak W75 h W75 = 0.961 qp^−1.125 W75 = 1.312 qp^−1.003 W75 = 1.356 qp^−1.007
Width of rising limb at 50% of peak WR50 h WR50 = 1.150 qp^−0.829 WR50 = 0.808 qp^−1.053 WR50 = 0.954 qp^−1.078
Width of rising limb at 75% of peak WR75 h WR75 = 0.527 qp^−0.932 WR75 = 0.542 qp^−0.965 (read by optical character recognition; reproduced by the report's worked example) WR75 = 0.581 qp^−1.035
Base width of UH TB h TB = 5.411 tp^0.826 TB = 7.621 tp^0.623 (read by optical character recognition; reproduced by the report's worked example) TB = 4.572 tp^0.90
Design storm duration TD h TD = 1.1 tp (it gave a higher 50-yr peak than TD = TB on all 16 catchments of the report) TD = 1.1 tp = 0.414 (L·Lc/√S)^0.434, rounded to the nearest whole hour TD = 1.1 tp [TBC]
Design loss rate — mm/h Falls with the duration of the storm (Fig. 13 of the report): about 3.5 for a 3-hour storm, falling to 1.5 for storms of about 13 hours or more, read by eye from the curve [TBC]; the worked example uses 2.1 for an 8-hour storm 7.5 (printed "0.75 cm/hr", the average adopted from 161 events on 26 catchments, against a modal value of about 6); probably high for Odisha [TBC]; see the note 5 on catchments larger than 75 km² and 2 on smaller ones (printed "0.5 cm/hr" and "0.2 cm/hr")
Design base flow — m³/s per km² 0.10 qb = 0.536 A^−0.523, A in km² 0.06
Ratio of t-hour to 24-hour rainfall — — 10-yr: 1 h 0.390; 3 h 0.610; 6 h 0.760; 9 h 0.820; 12 h 0.860; 15 h 0.880; 18 h 0.920; 24 h 1.000 50-yr: 1 h 0.42, or 0.35 for catchments near the coast; 2 h 0.525; 3 h 0.58; 6 h 0.69; 9 h 0.77; 12 h 0.84; 15 h 0.90; 18 h 0.94; 24 h 1.00 10-yr: 1 h 0.320; 3 h 0.500; 6 h 0.635; 9 h 0.730; 12 h 0.800; 15 h 0.864; 18 h 0.917; 24 h 1.000
Time distribution of 24-hour rainfall — cumulative fraction, hours 1 to 24 [TBC] [TBC] [TBC]
Conversion of 1-day to 24-hour rainfall — factor 1.15 1.15 1.15
Areal reduction factor ARF — [TBC] Table 5 of the report, read by optical character recognition only [TBC] [TBC]
Catchment area for which the relationships apply A km² 25–1,000; up to 5,000 with judgement 25–2,500; up to 5,000 with judgement [TBC]
Report reference — — Table 3.3 (p. 13), §3.5 (p. 14), §3.6 (p. 15), Annex 5.2 and Fig. 13 §3.9 (pp. 37–38), §3.11 and §3.12 (pp. 40–41) and Fig. 10 §3.3 to §3.5 (pp. 12–13)
Parameter Symbol Unit Subzone 1(g), hilly region Subzone 1(g), plain region Subzone 3(f) relationship
Time from centre of unit rainfall to peak tp h tp = 1.1808 (L·Lc/√S)^0.285 tp = 1.8833 qp^−0.940 tp = 0.348 (L·Lc/√S)^0.454
Peak discharge per unit area qp m³/s per km² qp = 2.0972 tp^−0.927 qp = 0.6617 (L/√S)^−0.515 qp = 1.842 tp^−0.804
Width of UH at 50% of peak W50 h W50 = 1.2622 tp^0.828 W50 = 1.7897 qp^−1.006 W50 = 2.353 qp^−1.005
Width of UH at 75% of peak W75 h W75 = 0.7896 tp^0.711 W75 = 0.8955 qp^−1.061 W75 = 1.351 qp^−0.992
Width of rising limb at 50% of peak WR50 h WR50 = 0.5357 tp^0.745 WR50 = 0.5524 qp^−1.012 WR50 = 0.936 qp^−1.047
Width of rising limb at 75% of peak WR75 h WR75 = 0.3825 tp^0.647 WR75 = 0.2984 qp^−1.012, as printed (the same exponent as WR50) [TBC] WR75 = 0.579 qp^−1.004
Base width of UH TB h TB = 5.5830 tp^0.824 TB = 12.4755 tp^0.721 TB = 4.589 tp^0.894
Design storm duration TD h TD = 1.1 tp TD = 1.1 tp TD = 1.1 tp
Design loss rate — mm/h 2.7 (printed "0.27 cm/hr" for every catchment in the subzone) 2.7 (the subzone value) 2 (printed "0.2 cm/hr")
Design base flow — m³/s per km² 0.05 0.05 0.05
Ratio of t-hour to 24-hour rainfall — — 10-yr: 1 h 0.350; 3 h 0.515; 6 h 0.640; 9 h 0.735; 12 h 0.800; 15 h 0.860; 18 h 0.915; 24 h 1.000 as hilly region 10-yr: 1 h 0.32; 3 h 0.52; 6 h 0.65; 9 h 0.73; 12 h 0.79; 15 h 0.85; 18 h 0.91; 24 h 1.00
Time distribution of 24-hour rainfall — cumulative fraction, hours 1 to 24 [TBC] [TBC] [TBC]
Conversion of 1-day to 24-hour rainfall — factor 1.15 1.15 1.15
Areal reduction factor ARF — Annex 4.2 of the report, read by optical character recognition only [TBC] as hilly region [TBC] in an annex missing from the copy read [TBC]
Catchment area for which the relationships apply A km² 25–1,000; up to 5,000 with judgement 25–1,000; up to 5,000 with judgement 25–1,000; above that with judgement
Report reference — — Tables 3.1 and 3.2 (pp. 13–14), §3.5 and §3.6 (pp. 15–16) Tables 3.1 and 3.2 (pp. 13–14), §3.5 and §3.6 (pp. 15–16) [TBC]

Note: relationships as printed in the five CWC reports that cover Odisha (References of Chapter 3); L, Lc and S are in the units each report defines. The subzone 3(d) and 4(a) relationships, loss rates, base flows and rainfall ratios were read from scanned copies and checked against the page images, except the WR75 and TB relationships of subzone 4(a), which were read by optical character recognition and are confirmed by the report's worked example. The subzone 1(g) entries were read from the same report for the edition of this Manual that covers the rest of that subzone, and checked against the page images. The subzone 3(g) unit hydrograph relationships were read by optical character recognition only and are to be confirmed against the page images [TBC]; its loss rates, base flow and rainfall ratios were checked against them. The subzone 3(f) entries are from the main text of the revised report of 1995, whose annexes and plates were missing from the copy read. The subzone 3(g) report had no gauged catchment of its own and adopted the relationships of subzone 3(f) as they stood before that revision, which is why its column differs from the 3(f) column; each shall be used only in its own subzone. The report for subzones 4(a) to 4(c) gives one set of relationships for all three, from 25 of 37 gauged catchments, only six of them in subzone 4(a); in Odisha it applies to subzone 4(a) only. Its loss rate of 7.5 mm/h is two to five times the subzone 3(d) curve, although both reports describe mainly coastal alluvial and red soils, and a high loss rate lowers the effective rainfall and the peak, so it errs on the unsafe side. Until it is checked against Odisha events [TBC], this Manual requires that in subzone 4(a) the SUH also be computed with the subzone 3(d) loss curve, and that the higher 1% AEP peak be adopted, unless calibration under Clause 3.15 supports the other. The 4(a) report allows a 1-hour ratio of 0.35 in place of 0.42 for catchments near the coast; it applies at Gopalpur, Chhatrapur and on the shore of Chilika. The subzone 3(d) report of 1997 kept the loss curve of its 1982 edition, although 28 new events it examined lie considerably outside the curve, and the curve was read by eye [TBC]. In subzone 1(g) the hilly region covers the plateau and its foothills, with slopes above about 2 m/km, and in Odisha takes in the upper Budhabalanga and Subarnarekha in Mayurbhanj; the plain region takes in the Balasore coast [TBC]. In the 1(g) plain region the WR75 exponent is printed the same as the WR50 exponent, which may be a misprint [TBC]. Where a catchment drains across the boundary between two subzones, or the boundary near it is uncertain, this Manual requires the SUH to be computed with the parameters of each subzone and the higher 1% AEP peak to be adopted, unless calibration under Clause 3.15 supports the other. Bhubaneswar lies on the boundary between subzones 3(d) and 4(a): its drainage to the Kuakhai, the Daya and the Gangua nala belongs to the Mahanadi delta, while the land of Khordha that drains to Chilika lies in 4(a); both shall be computed there. The same applies at Balasore, on the boundary between subzones 1(g) and 3(d), and on the Koraput–Jeypore plateau, near the junction of subzones 3(g), 3(f) and 4(a). The worked examples reproduce from these relationships: for subzone 3(d) (railway bridge 385 near Sondur, 194 km², L = 39.36 km, Lc = 15.13 km, S = 4.36 m/km) the relationships give tp = 7.68 h, which the report rounds to 7.5 h, and the report gives qp = 0.29 m³/s per km², TB = 29 h and a 50-yr peak of 1,086.5 m³/s; for subzones 4(a) to 4(c) (railway bridge 85 near Nagari, in subzone 4(b), 785 km²) they give tp = 6.18 h, which the report rounds to 6.5 h, and a base flow of 12.9 m³/s, against 12.88 m³/s printed, and the report gives a 50-yr peak of 2,150 m³/s. The 4(a) report also gives simplified flood formulae for preliminary designs only; they shall not be used under Clause 3.11.4. No gauged deltaic, tidal or urban catchment in Odisha lies behind any relationship in these tables. In Cuttack, Bhubaneswar, Puri, Paradip and the other flat, embanked, gated or pumped catchments of the delta and the coast the SUH describes neither the catchment nor its outfall: it is a benchmark for the natural condition only (Clause 3.11.4(c)), and the design is made with a hydrograph model and the tailwater of Chapter 5. Subzone by basin, to be confirmed on the index maps of the reports [TBC]: 3(d), the Mahanadi, the Brahmani and the Baitarani, and the coast between their mouths (Cuttack, the Mahanadi side of Bhubaneswar, Puri, Konark, Paradip, Jagatsinghpur, Kendrapara, Jajpur, Bhadrak, Chandbali and Dhamra, Angul and Talcher, Dhenkanal, Sambalpur, Jharsuguda, Rourkela, Sundargarh, Keonjhar, Bolangir, Bhawanipatna and Phulbani); 4(a), the Rushikulya, the Bahuda, the Vamsadhara and the rivers that drain to Chilika (Berhampur, Gopalpur, Chhatrapur, Aska, Bhanjanagar, Paralakhemundi, Gunupur, part of Rayagada, and the Chilika shore at Balugaon and Satapada); 1(g), the Subarnarekha and the Budhabalanga (Balasore, Jaleswar, Baripada, Rairangpur and Udala); 3(g), the Indravati (Nabarangpur, Umerkote, part of Jeypore and the south-west of Kalahandi); 3(f), the Sabari (Kolab) and the Sileru (Koraput, Sunabeda, Malkangiri and Motu). No part of Odisha lies in subzone 3(e) or 4(b). The subzone is chosen by the catchment's outfall, not by its district.

Table 3E.2 — Worked example outline (layout)

Step Content Clause
1 Catchment area, main stream length, length to centroid and equivalent slope, from survey or DEM 3.11.4(a)
2 SUH parameters from Table 3E.1 and the plotted unit hydrograph 3.11.4(a)
3 Design storm duration, point and areal 24-hour rainfall with climate factor, time distribution 3.11.4(a), (b)
4 Effective rainfall after the design loss rate; convolution with the SUH; base flow added 3.11.4(a)
5 1% AEP peak compared with the HEC-HMS or SWMM peak for the existing natural condition 3.11.4(c), (d)

Form 3-1 — Hydrologic Calculation Summary

Supports Clauses 3.4, 3.6, 3.7, 3.8, 3.10–3.13, 3.15–3.17 of Chapter 3.

Draft form — Odisha Stormwater Design Manual, Draft v1.0. One form per submittal. Attach the documents listed in Section H.

A. Project

Table 3F.1 — Form 3-1: project

Field Entry
A1. Project name and applicant  
A2. Location (village or ward, survey numbers, district)  
A3. Site area (ha) and number of points of comparison (POCs)  
A4. Catchment class: standard (Clause 2.11.2) or flood-sensitive (Clause 2.11.3)  
A5. Design Rainfall Sheet reference (Form 2-1)  

B. Method and software (Clauses 3.4, 3.11, 3.12, 3.16)

Table 3F.2 — Form 3-1: method and software

Field Entry
B1. Purpose of each calculation (conveyance, storage, comparison, catchment study)  
B2. Contributing area for each purpose (ha or km²)  
B3. Method used and the row of Table 3.1 that permits it  
B4. Reason for the choice of method  
B5. Software and version; engine and version for packages built on SWMM or HEC (Clause 3.16.1, 3.16.2)  
B6. For other software: benchmark results of Annex 3C attached (Table 3C.7) and the 5% comparison of Clause 3.16.2  
B7. Runoff transform (Clause 3.11.1)  
B8. Computation interval Δt (h), with 0.133 Tc of the smallest sub-area and the hyetograph time step (Clause 3.11.3(a))  
B9. Storage routing and channel routing methods (Clauses 3.12.1, 3.12.2)  
B10. Dynamic-wave routing required? If yes, which condition of Clause 3.12.4  
B11. CWC SUH benchmark required (25–5,000 km², Clause 3.11.4)? Result reference  
B12. Continuous simulation required (Clause 3.13.1)? Record used and starting tank levels (Clause 3.13.5)  
B13. Calibration required (Clause 3.15.1)? Calibration report reference  

C. Soils and groundwater (Clauses 3.3.3(b), 3.7, 3.10)

Table 3F.3 — Form 3-1: soils and groundwater

Field Entry
C1. HSG source map, scale and lookup used (Clause 3.7.1, Annex 3A) or NEH Part 630, Ch. 7 assignment (Clause 3.7.2)  
C2. Infiltration tests: number, locations, depths, results (Clause 3.7.3)  
C3. Seasonal high water table: depth below ground and source (Clause 3.10.2)  
C4. Areas within 0.6 m assigned HSG D (Clause 3.10.1)  
C5. Disturbed pervious areas and HSG downgrade applied (Clause 3.3.3(b))  

D. Parameters by sub-area and condition (Clauses 3.3, 3.5, 3.8, 3.9; Clause 3.17 item 4)

Table 3F.4 — Form 3-1: parameters by sub-area and condition

Sub-area Condition (pre / post) Area (ha) Impervious: roofs / paved / roads (ha) DCIA (ha) Disconnected (ha) HSG CN, AMC II CN, AMC III (pervious part) C and Cf (if Rational) Tc (min)
                     
                     
                     

E. Time of concentration worksheet (Clause 3.6)

One worksheet per sub-area and condition.

Table 3F.5 — Form 3-1: time of concentration worksheet

Segment Flow type Surface and n (Table 3.4) L (m) S (m/m) P2 (mm) V (m/s) Tt (min)
1 Sheet         —  
2 Shallow concentrated       —    
3 Channel or pipe       —    
Tc (not less than 10 min)  

E1. Is the post-development Tc shorter than the pre-development Tc? If not, explain (Clause 3.6.6): ______

F. Rainfall and losses (Clauses 3.8.4, 3.8.5, 3.11.5, 3.12, 3.3.5)

Table 3F.6 — Form 3-1: rainfall, losses and starting levels

Field Entry
F1. AEPs and durations run; climate factor applied (Chapter 2)  
F2. AMC used for each duration (Clause 3.8.4)  
F3. Ia ratio for design runs; Ia = 0.05S sensitivity run made (Clause 3.8.5)  
F4. Peak rate factor used; if lower than 484, the Annex 3D value and the land it applies to (Clause 3.11.5)  
F5. Starting water level of each tank or waterbody, and its basis (Clauses 3.12.5, 3.13.5)  
F6. Off-site run-on: land use assumed for conveyance and for the comparison (Clause 3.3.5)  
F7. Incidental storage counted? If yes, the authority's acceptance (Clause 3.12.3)  

G. Departures

Table 3F.7 — Form 3-1: departures from Chapter 3

No. Clause departed from Value used in place of the Chapter 3 value Justification
1      
2      

H. Attachments (Clause 3.17)

Table 3F.8 — Form 3-1: attachments

Item Attached (yes / no / not applicable) Reference
H1. Catchment maps, pre- and post-development, with sub-areas, Tc flow paths, POCs and off-site run-on    
H2. HSG map, water-table data and infiltration test results    
H3. Parameter tables (Section D) and Tc worksheets (Section E)    
H4. Design Rainfall Sheet (Form 2-1) and hyetographs    
H5. Hydrograph tables and plots; stage–storage and stage–discharge tables; routed outflows; peak water levels    
H6. Form 3-2 for each POC    
H7. Calibration report (Clause 3.15)    
H8. Native model input and output files (Clause 3.16.4)    

I. Statement by the responsible engineer (Clause 3.17 item 10)

I state that the methods and parameters of Chapter 3 of the Odisha Stormwater Design Manual (Draft v1.0) have been used in this submittal, and that every departure is listed and justified in Section G.

Table 3F.9 — Form 3-1: statement by the responsible engineer

Field Entry
Name  
Qualification and registration number  
Organisation  
Signature  
Date  

Draft form — Odisha Stormwater Design Manual, Draft v1.0.


Form 3-2 — Pre- vs Post-Development Comparison

Supports Clauses 3.8.5, 3.11.5 and 3.14 of Chapter 3.

Draft form — Odisha Stormwater Design Manual, Draft v1.0. One form for each point of comparison (POC). Flows in m³/s, volumes in m³.

A. Point of comparison (Clause 3.14.2)

Table 3F.10 — Form 3-2: point of comparison

Field Entry
A1. POC identifier and location  
A2. Area draining to the POC: site (ha) and off-site run-on (ha)  
A3. Off-site run-on passes through site storage? (Clause 3.14.2(c))  
A4. Catchment class: standard (Clause 2.11.2) or flood-sensitive (Clause 2.11.3)  
A5. Tailwater applied, including joint cases of Clause 2.12 (Clause 3.14.9(c))  
A6. Flood-sensitive only: largest 10% AEP pre-development peak over all durations, the cap of Clause 2.11.3 (Clause 3.14.7)  
A7. Flood-sensitive only: 50% AEP pre-development peak at the pre-development critical duration (Clause 2.11.3)  

B. Peak flows (Clauses 3.14.7–3.14.10)

Limit: standard catchments 0.9 × Q_pre for the same AEP and duration (Clause 3.14.10(a)); flood-sensitive catchments the caps A6 (for 1% AEP) and A7 (for 50% AEP) (Clause 3.14.10(b)).

Table 3F.11 — Form 3-2: peak flows by AEP and duration

AEP Duration (h) AMC Q_pre Q_post, uncontrolled Q_post, routed Limit Met?
50% (2-yr) 1 II          
50% (2-yr) 2 II          
50% (2-yr) 3 II          
50% (2-yr) 6 II          
50% (2-yr) 12 III          
50% (2-yr) 24 III          
50% (2-yr) 48 III          
50% (2-yr) 72 III          
10% (10-yr) 1 II          
10% (10-yr) 2 II          
10% (10-yr) 3 II          
10% (10-yr) 6 II          
10% (10-yr) 12 III          
10% (10-yr) 24 III          
10% (10-yr) 48 III          
10% (10-yr) 72 III          
1% (100-yr) 1 II          
1% (100-yr) 2 II          
1% (100-yr) 3 II          
1% (100-yr) 6 II          
1% (100-yr) 12 III          
1% (100-yr) 24 III          
1% (100-yr) 48 III          
1% (100-yr) 72 III          

C. Volumes and storage (Clauses 3.14.8–3.14.10)

Table 3F.12 — Form 3-2: volumes and storage

AEP Governing duration (h) Runoff volume, pre Runoff volume, post uncontrolled Retention volume Detention storage required Peak water level in storage (m)
50% (2-yr)            
10% (10-yr)            
1% (100-yr)            

C1. Governing duration for storage, and the 24, 48 and 72 h results (Clause 3.14.10): ______

D. Sensitivity runs (Clauses 3.8.5, 3.14.11)

Table 3F.13 — Form 3-2: sensitivity runs

Run Governing storm (AEP, duration) Change in Q_post, routed (%) Change in required storage (%) Retention volume or WQv governing (Clause 3.8.5(c))
Ia = 0.05S        
Standard peak rate factor (only where a lower factor is used)       —

E. Associated checks (Clause 3.14.12)

Table 3F.14 — Form 3-2: associated checks

Check Result Reference in submittal
Drawdown times (Chapter 4)    
Minimum orifice and trash screen (Chapter 4)    
Emergency spillway (Chapter 4)    
Outfall-closed storage check (Chapter 5)    
Downstream analysis (Chapter 5)    

F. Statement by the responsible engineer

I state that this comparison has been made by the procedure of Clause 3.14, with the same design storms in the pre- and post-development runs, and that no runoff has been diverted from one natural catchment to another to meet the criterion (Clause 3.14.2(b)).

Table 3F.15 — Form 3-2: statement by the responsible engineer

Field Entry
Name  
Qualification and registration number  
Signature  
Date  

Draft form — Odisha Stormwater Design Manual, Draft v1.0.