Draft v1.0 prepared by NEER. Not adopted by the Government of Odisha, and has no legal force. About this draft

Chapter 2Design Rainfall and Design Storms


2.1 Purpose and scope

2.1.1 This chapter sets the rainfall inputs for every hydrologic calculation in this Manual: drain and inlet sizing (Chapter 6), retention and detention sizing (Chapter 4), downstream and tailwater analysis (Chapter 5), and waterbody and tank works (Chapter 7).

2.1.2 It specifies:

  • (a) the approved sources of design rainfall depth and intensity;
  • (b) how depths are converted between durations, between point and area, and from present to future climate;
  • (c) how design storms (hyetographs) are constructed; and
  • (d) the storms that must be applied to pre- and post-development conditions.

2.1.3 This chapter applies throughout Odisha. Where a Municipal Corporation, a Municipality, a Notified Area Council or a development authority has adopted a stricter rainfall standard under Chapter 1, the stricter standard governs.

Commentary. Most past drainage failures in Odisha trace to the rainfall input, not the hydraulics. Odisha shows how. No design-intensity table, return period or IDF relationship was found for any city in the State in research for this Manual. BMC told the CAG that its drains were "designed as per discharge calculation of runoff in empirical formula so that it would be sufficient for coming 50 years", but the CAG "did not find any design discharge for runoff calculation of rain water in estimates", and found that "primary and secondary drains had been constructed without considering the rainfall data, or the required width" (CAG, 2024). The one numeric criterion found, for Cuttack, is an outcome target of the JICA-financed project, fewer than three inundations a year, not a design storm (JICA). The two published sources that seem to fill the gap do not. IMD Das et al. (2022) has no panel for any Odisha station. NIH-DHAARA's reanalysis-based 24-hour depths agree with the CWC plates at Cuttack and Balasore but are up to about 45% higher on the south and central coast, while its 1-hour depths are more than a third below the values the CWC ratios give (Clause 2.3.6). Fixing one transparent source and method for the whole state is the main purpose of this chapter.


2.2 Definitions

Term Meaning in this Manual
Annual exceedance probability (AEP) Probability that a given rainfall depth is equalled or exceeded in any one year. A 1% AEP storm is the "100-year" storm. Both forms are used here: T-year = 1/AEP.
IDF / DDF Intensity–duration–frequency and depth–duration–frequency relationships for a location.
Point rainfall Rainfall at a single location, as measured by a rain gauge.
Design storm A hyetograph (rainfall depth versus time) of stated AEP, duration and temporal pattern.
Critical duration The storm duration that produces the largest peak flow, water level or storage requirement for the element being designed.
Areal reduction factor (ARF) Ratio of catchment-average rainfall to point rainfall for the same AEP and duration.
SW monsoon season (JJAS) June–September, when the State receives about 80% of its annual rainfall: a State mean of 1,160.2 mm in June–September out of 1,447.8 mm a year, for 1989–2018, with July (349.8 mm) and August (357.3 mm) the wettest months (IMD, 2020). Annual means range from about 1,141 mm in Nuapada and 1,306 mm in Ganjam to 1,594 mm in Cuttack and 1,748 mm in Balasore (IMD, 2020). The share of the season varies widely: Sonepur receives 91% of its rain in June–September and Gajapati only 65% (IMD, 2020). Onset is in the first week of June at Balasore, the second at Cuttack and the third at Bhubaneswar (Khordha), Puri and Sambalpur (ICAR-CRIDA). The antecedent moisture rule of Clause 2.11.4 refers to this season; the pre-monsoon deadline of 30 April is set ahead of both this season and the May cyclones.
Cyclone months (May and October) Months outside the season in which cyclones and depressions from the Bay of Bengal, and the storms before the monsoon, bring some of the State's largest storms. With the SW monsoon season they form the design season of this Manual: no design storm, works deadline or operating rule shall assume that heavy rain is confined to June–September. May records include 263.8 mm in 24 hours at Paradip on 25 May 2009, that station's all-time record, 258.5 mm at Balasore on 27 May 1989, and 252.5 mm at Bhubaneswar and 236.0 mm at Cuttack on 11 May 1995, a month in which Bhubaneswar received 705.0 mm, Cuttack 738.4 mm and Puri 786.5 mm (IMD). October records include the all-time 24-hour records of Gopalpur (510.8 mm, 24 October 1954), Baripada (467.4 mm) and Chandbali (437.1 mm) on 12 October 1973, and Bhubaneswar (426.4 mm, 30 October 1999) (IMD). Fani (3 May 2019), Amphan (20 May 2020) and Yaas (26 May 2021) struck in May; the cyclones of 17–18 and 29 October 1999, Phailin (12 October 2013), Hudhud (12 October 2014), Titli (11 October 2018) and Dana (25 October 2024) in October. On the south coast about a third of the year's rain falls outside June–September (IMD, 2020). Design statistics use annual maxima from all seasons, and Clause 2.11.4 applies AMC III to the design storms of October on the coastal plains and deltas and to every named-cyclone design storm.
Climate factor (CF) Multiplier applied to present-day design depths to represent the design-life climate.
Approved source A rainfall source listed in Clause 2.3.

2.3 Approved sources of design rainfall

2.3.1 Primary source. Design rainfall depths and intensities shall be taken from the National Institute of Hydrology, Roorkee NIH-DHAARA platform (Design Hydrology and Advanced Rainfall Analysis, nihdhaara.in). Use its IDF / frequency tools for the site's coordinates, for each duration and AEP required by Clause 2.4. In Odisha this clause is suspended until Annex 2A is published: Clause 2.3.6 sets the interim source.

2.3.2 Station IDF. A station-specific IDF relationship may be used in place of 2.3.1 only if all of the following hold:

  • (a) it is derived from at least 30 years of recording-gauge (hourly or finer) data;
  • (b) it has been published or approved by IMD, the State Hydrology Authority or the approving authority; and
  • (c) the gauge is within 10 km of the site, with no major change of terrain or coastal exposure in between.

Where a station IDF is used, the design value shall be the greater of the station value and the NIH-DHAARA value.

2.3.3 Cross-checks (mandatory, not alternatives). The designer shall report, but need not adopt, the following values for comparison:

  • (a) the IMD isopluvial / IDF values of Das et al. (2022), MAUSAM 73(4), for durations of 1–24 h;
  • (b) for catchments of 25–5,000 km², the 24-hour point rainfall from the CWC Flood Estimation Report for subzone 1(g) (Lower Ganga Plains), 3(d) (Mahanadi), 3(f) (Lower Godavari), 3(g) (Indravati) or 4(a) (Upper Eastern Coast), as applicable.

Where the design value is lower than the CWC 1(g)/3(d)/3(f)/3(g)/4(a) value for the same AEP, the CWC value shall be adopted as a floor.

2.3.4 Not permitted. None of the following shall be used as a design rainfall source:

  • (a) generalised all-India IDF formulae (for example Kothyari & Garde, 1992);
  • (b) rainfall values that cite no source, including vendor or web-calculator tables;
  • (c) single-event maxima; or
  • (d) design intensities carried forward from a previous project without a stated AEP.

CWC FER, 5 subzones Interim primary source (Cl. 2.3.6) 24-h plates × subzone ratios Approved station IDF ≥30 yr recording gauge, ≤10 km optional (Cl. 2.3.2) Take the greater per AEP and duration Station annual maxima 2–10 yr depths (Cl. 2.3.6(b)) NIH-DHAARA reported for comparison only Adjustments, in order 1. Fixed-interval → true-interval (Cl. 2.6.3) 2. Grid → point, if grid values (Cl. 2.7.1) 3. Areal reduction, >10 km² only (Cl. 2.7.3) 4. Climate factor 1.20 / 1.10 (Cl. 2.8) → Design depth → hyetograph (Cl. 2.9) Odisha (Cl. 2.3.6): station maxima give the 2–10 yr depths the FER plates lack; NIH-DHAARA is reported on Form 2-1 for comparison.

Figure 2.1 — Design rainfall source hierarchy and adjustment sequence. Original drawing for this Manual.

2.3.5 Version control. Every submittal shall record the source, its version or access date, the coordinates queried, and the values extracted (Clause 2.13).

2.3.6 Interim source in Odisha. Until Annex 2A is published and confirms NIH-DHAARA, or an approved station IDF, for a zone, Clause 2.3.1 does not apply in Odisha, and design rainfall shall be taken as follows:

  • (a) 24-hour depth, 4%, 2% and 1% AEP (25-, 50- and 100-yr). The 24-hour point value at the site read from the isopluvial plates of the CWC Flood Estimation Report for the subzone that contains the site, whatever the catchment area: 3(d) (Mahanadi, revised 1997) in the basins of the Mahanadi, the Brahmani and the Baitarani and their delta, from Sambalpur, Jharsuguda, Rourkela and Angul to Cuttack, Puri, Paradip, Jajpur and Bhadrak, which is most of the State; 4(a) (Upper Eastern Coast, 1987) in the basins of the Rushikulya, the Bahuda and the Vamsadhara and of Chilika, including Berhampur, Gopalpur and Gunupur and the south of Khordha district; 1(g) (Lower Ganga Plains, revised 1994) in the basins of the Subarnarekha and the Budhabalanga, including Balasore, Jaleswar and Baripada; 3(g) (Indravati, 1993) in Nabarangpur district and on the Indravati side of Koraput and Kalahandi districts; and 3(f) (Lower Godavari, 1995) in the basins of the Kolab (Sabari) and the Sileru in Koraput and Malkangiri districts (Annex 2A). Within 5 km of a subzone boundary, and wherever the plates of two reports cover the site, the higher of the two plate values is used. Bhubaneswar lies on the boundary of 3(d) and 4(a), and Balasore on the boundary of 1(g) and 3(d); the higher value is used throughout the area of the Bhubaneswar Municipal Corporation and of Balasore Municipality. The 3(f) plates are missing from the copy of that report read for this Manual, and the 3(d) contour labels around Sambalpur, Jharsuguda and Rourkela could not be read on the available scan [TBC]; there, and wherever no plate for one of these AEPs can be read for the site, the depth for that AEP is the station estimate of (b), and is recorded as such on Form 2-1. For orientation only, and read by eye to about one contour, the plates give about 360–400 mm at Cuttack, 320–360 mm at Bhubaneswar and Puri, 400 mm or more on the Paradip–Jagatsinghpur coast, 320–360 mm at Balasore and Chandbali, 280–320 mm at Baripada and Berhampur, with a cell above 360 mm just inland of Berhampur, about 280 mm on the Gopalpur coast, 240–280 mm at Nabarangpur, 280–360 mm towards Jeypore and Koraput, and more than 440 mm in the Keonjhar–Mayurbhanj hills for the 50-year storm.
  • (b) 24-hour depth, more frequent AEPs (2-, 5- and 10-yr). The reports have no plates for these. The depth is the Gumbel (EV1) estimate from the annual maximum daily rainfall series, of all months, of the IMD station agreed with the Authority, multiplied by the fixed-interval factor of Clause 2.6.3. In Bhubaneswar and Cuttack it is the higher of the estimates for Bhubaneshwar (A), 42971, and Cuttack, 42970; elsewhere the station is, for example, Puri, 43053; Paradip Port, 42976; Gopalpur, 43049, for Berhampur; Balasore, 42895; Chandbali, 42973; Baripada, 42894; Sambalpur, 42883; Jharsuguda (A), 42886, for Rourkela; or Koraput, 43097; or else the nearest IMD station with 30 or more years of record, from the candidates in Annex 2A.
  • (c) 48- and 72-hour depths. The Gumbel estimate from the annual maximum 2-day and 3-day rainfall series of the same station or stations, with the fixed-interval factors of Clause 2.6.3, and not less than the 24-hour depth for the same AEP.
  • (d) Durations shorter than 24 hours. The 24-hour depth multiplied by the ratios of the report for the site's subzone in Table 2B.1, at every AEP. The 1-hour ratio is 0.390 in 3(d), 0.42 in 4(a), 0.350 in 1(g) and 0.320 in 3(g) and 3(f). The 4(a) report allows 0.35 at 1 hour for catchments near the coast; that allowance is not used until Annex 2B is published, because the report does not define how near, and the 0.42 of the subzone as a whole applies on the Gopalpur coast and the shore of Chilika (set by this Manual). Where (a) takes the higher of two subzones, the depth at each duration is the higher of the two products. Between the tabulated durations the ratio is interpolated on logarithmic axes. Below 1 hour, the ratio is agreed with the Authority and recorded on Form 2-1 until Annex 2B gives one.
  • (e) Short storms and cyclone days. The 1-hour depths given by (d), about 125–140 mm at Bhubaneswar and 140–156 mm at Cuttack for the 50-year storm, exceed every 1-hour fall in the reports' recording-gauge records for Odisha: 83 mm at Bhubaneswar on 23 June 1979 and at Naraj, by Cuttack, and 100 mm at Akhuapada and at Bangriposhi (CWC, 1997; CWC, 1994). The 50-year 3-hour depth at Bhubaneswar, about 195–220 mm, is about twice the largest 3-hour fall recorded there, 110 mm. Those records end in the 1970s and 1980s, no primary sub-daily record of a recent Odisha storm was found in research for this Manual, and NIH-DHAARA gives only 80–103 mm for the 50-year hour at the places queried. At 24 hours the cyclone records point the other way: 510.8 mm at Gopalpur on 24 October 1954, against a 100-year plate value of about 320 mm, and 426.4 mm at Bhubaneswar on 30 October 1999, against about 360 mm, while Baripada recorded 467.4 mm and Chandbali 437.1 mm on 12 October 1973, against 50-year plate values of about 280–320 mm and 320–360 mm (IMD; CWC). Whether the plates overstate the short storms and understate the cyclone days is not resolved; frequency analyses of the IMD recording-gauge and daily series under Annexes 2A and 2B are needed to show it. Until then, the depths of (a) and (d) are used as they stand, and are not reduced towards the recorded hourly maxima or towards NIH-DHAARA.
  • (f) NIH-DHAARA. Its present-day values at the site are reported on Form 2-1 beside the interim values, for comparison only. Its projected depths are not used under Clause 2.8.4; the ratio of its projected to its present-day depths may be reported as a check on the climate factors of Table 2.2, which apply.
  • (g) Other clauses. Where Clauses 2.3.2, 2.6.1, 2.7.1 and 2.13, Annexes 2A to 2C and Form 2-1 refer to the NIH-DHAARA value, the value under this clause is meant.

Commentary. NIH-DHAARA is a national, publicly accessible product from a Government of India institution, and it can be queried at any point in the State. That makes it a reproducible default that an approving authority can check. NIH-DHAARA's sub-daily values are derived from hourly records, not disaggregated from daily totals. That makes it the only public source suitable for sizing drains, which depend on short-duration intensity. Its values should still be checked against the long IMD daily record at 24 hours and longer (Annex 2A). In Odisha the platform does not yet meet that purpose. Its present-day values there come from IMDAA reanalysis (about 12 km) for 2000–2022, not from gauges, and they err in both directions. Its 50-year 24-hour depths are close to the CWC plates at Cuttack (about 364 mm against about 360–400 mm), Balasore (339 mm against about 320–360 mm) and Koraput (359 mm against about 320–360 mm), but far above them on the south and central coast: 457 mm at Puri against about 320–360 mm, and more than the 362.3 mm that is Puri's highest day in some 150 years of record; 406 mm at Berhampur and Gopalpur against about 280–320 mm; 452 mm at Paradip; and 382 mm at Bhubaneswar against about 320–360 mm. Its 50-year 1-hour depths, about 80–103 mm, are 35–40% below the values the CWC ratios give (Clause 2.3.6(e)) (NIH-DHAARA, queried 6 Nov 2026; IMD; CWC). A source that overstates the coast by up to about 45% at 24 hours and disagrees with the plates by more than a third at 1 hour cannot be adopted zone by zone until the benchmark checks of Annex 2A show where it holds. Clause 2.3.6 therefore uses the CWC reports and the long IMD station records until Annex 2A has been done, and uses NIH-DHAARA for comparison and as a check on the climate factors only. The interim rules for the more frequent AEPs, the 48- and 72-hour depths, the subzone boundaries, the Bhubaneswar and Balasore rules, the 4(a) coastal ratio and durations between the tabulated ratios are set by this Manual. Several points in the reports are unresolved. The plate values were read by eye and are approximate, to about one contour; Cuttack reads about the same on the 50- and 100-year plates of the 3(d) report, which a better scan should check; the 3(d) contour labels near Sambalpur, Jharsuguda and Rourkela, and the plates of the 3(f) report, could not be read [TBC]; and the subzone boundaries at Bhubaneswar, Balasore and Koraput are to be confirmed on the CWC index maps [TBC]. The 3(d), 3(g), 3(f) and 1(g) ratios were derived for the 10-year storm and the 4(a) ratios for the 50-year storm. The reports' annexes also give some one-day maxima that differ from the IMD station records, among them 48.0 cm at Puri in 1862 and 41.7 cm at Cuttack in 1934 in the 3(d) report, against IMD records of 362.3 mm and 330.2 mm; this Manual uses the IMD records. IMD Das et al. (2022) has no panel for any Odisha station, so the cross-check of Clause 2.3.3(a) is recorded on Form 2-1 as not available; its regional ranges do not say which region Odisha belongs to, and every one of their 24-hour upper bounds is below the State's cyclone records.


2.4 Design return periods (summary)

2.4.1 Design AEPs are set in the chapters for each element. They are summarised here so that the correct rainfall is extracted at the start of design.

Table 2.1 — Design return periods (summary)

Element Design AEP (return period) Check event Chapter
Minor drains: Bhubaneswar, Cuttack and Berhampur core and high-density areas 10% (10-yr) 1% (100-yr) overland path 6
Minor drains: other Class I urban areas 20% (5-yr) 1% overland path 6
Minor drains: other areas 50% (2-yr) 1% overland path 6
Arterial roads and crossings 2–4% (25–50-yr) next higher AEP 6
Collector / local roads 4% / 10% (25 / 10-yr) 2% / 4% (50 / 25-yr), plus the 1% overland path 6
Major (overland) system 1% (100-yr) — 6
Retention volume Percentile daily rainfall (Clause 2.10) — 4
Detention: standard catchments 50%, 10%, 1% (2, 10, 100-yr) 1% emergency spillway 4
Detention: flood-sensitive catchments Mixed-frequency rule, Clause 2.11 1% 4
Building floor levels 1% + 0.5 m freeboard — 6
Detention emergency spillway 1% with outlet blocked 0.2% (500-yr) where high hazard 4

Commentary. These values exceed the CPHEEO (2019) national advisory minimums of 5-yr (Class I cities) and 2-yr (other areas). CPHEEO allows a State to set higher values. The values are set in Chapters 4 and 6, and the table is reproduced here for convenience.


2.5 Design durations

2.5.1 Conveyance elements (pipes, open drains, inlets, culverts) shall be designed with the intensity for a duration equal to the time of concentration (Tc) of the contributing area (Chapter 3). The minimum duration is 10 minutes.

2.5.2 Storage elements (detention, retention, tanks, pumped sumps) shall be checked for every duration in the set {1, 2, 3, 6, 12, 24, 48, 72 h}. The largest required storage or water level governs. The 24-, 48- and 72-hour storms are mandatory checks at every site, whatever the critical-duration result.

2.5.3 Tidally influenced outfalls. For storage draining to a tidally influenced outfall (Chapter 5), the 48- and 72-hour storms shall also be run with the tailwater boundary of Clause 2.12.

Commentary. Odisha's worst rainfall floods have come from long spells. In the super cyclone of October 1999, 400–955 mm fell in four days over the northern delta, with 4-day totals of 955 mm at Oupada and 940 mm at Paradip, and the Baitarani, Salandi, Budhabalanga, Kharasua and Brahmani rose in high flood, with 20,005 breaches in the embankments (Kalsi, 2006). The one-day value Kalsi gives for Paradip, 53.0 cm on 30 October 1999, is not in IMD's record for the Paradip Port observatory, whose highest day is 263.8 mm (25 May 2009); both are reported here, and the conflict is unresolved (Kalsi, 2006; IMD). In August 1982 a monsoon depression gave 581.9 mm in a day at Sambalpur (19 August) and 484.0 mm at Phulbani and 401.6 mm at Bolangir (30 August), and August 1982 is the wettest month on record at Sambalpur (1,283.7 mm) and Phulbani (1,189.8 mm) (IMD); the Mahanadi then peaked at about 44,900 m³/s at Mundali (Parhi et al., 2012). Monthly totals show the scale on the coast too: Bhubaneswar received 904.6 mm in October 1999, and Bhubaneswar, Cuttack and Puri 705–787 mm each in May 1995 (IMD). A rule based only on critical duration, applied to a small site, picks a 1–2 hour storm and misses this failure mode. That is why the long-duration checks are mandatory.


2.6 Sub-daily rainfall

2.6.1 Where NIH-DHAARA or an approved station IDF provides values directly for the required duration, those values shall be used.

2.6.2 Where only daily (24-hour) depths are available for a duration below 24 hours, the sub-daily depth shall be derived using the ratio set of Annex 2B. These are duration-to-24-hour ratios calibrated to Odisha recording gauges. They shall not be lower than the ratios of the CWC Flood Estimation Report for the subzone. IMD Das et al. (2022) has no Odisha station panel and is not used as a floor in Odisha.

2.6.3 Fixed-interval adjustment. Depths from fixed observation windows (for example 08:30–08:30 IST daily data, or clock-hour data) shall be converted to sliding-window ("true interval") depths:

  • 1.13 for a single fixed observation interval;
  • 1.04 for 2 intervals;
  • 1.02 for 3–4 intervals.

This adjustment does not apply where the approved source already gives true-interval values.

2.6.4 The empirical relationship P(t) = P(24)·(t/24)^(1/3) shall not be used for design unless Annex 2B confirms it for the zone concerned.

Commentary. The one-third power rule is common in Indian project reports, but no primary IMD source for it was found during research for this Manual. It applies one fixed curve shape everywhere: P(1h)/P(24h) = 0.35, P(3h) = 0.50, P(6h) = 0.63 and P(12h) = 0.79. It cannot represent the difference between a short convective burst and a long SW monsoon soak, and it tends to understate short-duration depths in convective coastal storms. Annex 2B shall tabulate the NIH-DHAARA ratios P(t)/P(24h) against these values by zone. That comparison shows whether the rule is acceptable anywhere in the State and corrects older daily-based analyses. The fixed-interval factors are the standard WMO (Hershfield) values. The IMD 2022 study applies similar clock-hour to any-hour corrections.


2.7 Point, grid and areal rainfall

2.7.1 Design depths are point values. Where an approved source provides grid-average values (for example 0.25° cells), they shall be converted to point values with the grid-to-point factors in Annex 2C before use.

2.7.2 For catchments ≤ 10 km², ARF = 1.0.

2.7.3 For catchments > 10 km², apply ARF as follows:

  • for 25–5,000 km² in subzone 1(g), 3(d), 3(f), 3(g) or 4(a): use the ARF curves of the applicable CWC Flood Estimation Report;
  • for 10–25 km²: interpolate linearly between ARF = 1.0 at 10 km² and the CWC value at 25 km².

2.7.4 An ARF shall never be applied to storage design for a single development site.

Commentary. Gridded and district-average return levels are much lower than point values. For example, the Gopalpur gauge recorded 510.8 mm in a day on 24 October 1954, more than the 100-year 24-hour depth of about 461 mm that NIH-DHAARA's IMDAA cell gives there (NIH-DHAARA, queried 6 Nov 2026; IMD). In Odisha the reanalysis cells also err the other way: at Puri the cell gives a 50-year 24-hour depth of about 457 mm, above the 320–360 mm of the CWC isopluvials and above any day in Puri's record of some 150 years (Clause 2.3.6). Neither error can be corrected without the factors of Annex 2C. Using grid values as point values without correction would make site-level design unsafe.


2.8 Climate factor

2.8.1 Until a statewide future-climate rainfall product is adopted, present-day design depths shall be multiplied by the following interim climate factors:

Table 2.2 — Interim climate factors

Duration Climate factor (CF)
≤ 6 h 1.20
> 6 h to 72 h 1.10

2.8.2 The CF applies to all elements with a design life of more than 25 years. For temporary works (design life ≤ 5 years), CF = 1.0.

2.8.3 The climate factor does not apply to the retention depth (Clause 2.10) or to the water quality volume depth (Chapter 8). Those depths are percentile or frequent-event statistics of everyday rainfall, not AEP design values.

2.8.4 Where NIH-DHAARA, or a product adopted on review under Clause 2.14, provides projected future-climate depths, those depths shall replace the interim factors.

Commentary. CPHEEO (2019) considers a fixed climate factor "not feasible" nationally and recommends trend testing instead. That leaves designers without a usable number. The 1.20 short-duration factor matches the UK value cited by CPHEEO itself. It is at or below published projections for India: Ali and Mishra (2018) project 3-hourly 100-year maxima rising by about 20% at 1.5 °C and 25% at 2.0 °C of warming. No Odisha or city design uplift factor was found. The State's climate change action plan projects changes in mean annual rainfall by district, from about −8% to +56% by mid-century under RCP 4.5, but gives no projection of extreme or sub-daily rainfall (Government of Odisha, SAPCC 2021–30). IMD's monograph for the State found no significant trend in State rainfall for 1989–2018, significant increases in heavy-rainfall days at stations in thirteen districts, most of them in the interior south and west, and significant decreases at stations in Puri, Khordha and Cuttack (IMD, 2020); a later study of 1991–2022 finds heavy rainfall rising in Koraput and Malkangiri and falling in Balasore and Jajpur (Mohanty et al., 2026). Recent single days nonetheless broke old records in the delta: 195 mm at Bhubaneswar and 341 mm at Puri on 13 September 2021, and 259.2 mm at Bhubaneswar on 1 August 2023 (as reported). One study projects the 100-year flood depth in Bhubaneswar rising from 0.75 m to 1.18 m by the far future under land-use and climate change (Das and Sahoo, 2025). NIH-DHAARA's bias-corrected CMIP6 runs could give a ratio of future to present depths; none has yet been computed for this Manual, and under Clause 2.3.6(f) it would serve only as a check. The factors of Table 2.2 are therefore interim values, not Odisha estimates.


2.9 Temporal patterns (design hyetographs)

2.9.1 Storms up to 24 hours. Use the nested alternating-block method:

  • construct the storm from the same IDF relationship (after the climate factor), at time steps no longer than Tc/3 and no longer than 15 minutes;
  • place the peak block at 50% of the storm duration.

2.9.2 48- and 72-hour storms (SW monsoon pattern). Construct as follows:

  • (a) The total storm depth equals the design depth for the full duration (48 or 72 h).
  • (b) The final 24 hours contain the 24-hour design depth for the same AEP, distributed by the alternating-block method of 2.9.1.
  • (c) The remaining depth (total minus the 24-hour depth) is spread uniformly over the preceding 24 or 48 hours.

2026-10-31T09:49:37.193022 image/svg+xml Matplotlib v3.9.4, https://matplotlib.org/ 0 6 12 18 24 Time (h) 0 10 20 30 40 50 60 70 80 Rainfall (mm per h) (a) 24-h alternating-block storm 0 12 24 36 48 60 72 Time (h) Remaining 72-h depth, spread uniformly (antecedent rain fills soils, RWH sumps, tanks) 24-h design depth on the final day (alternating block, Clause 2.9.1) (b) 72-h monsoon storm Illustrative — not design values (100-yr 24-h = 350 mm, 72-h = 520 mm, hourly blocks).

Figure 2.2 — (a) 24-hour alternating-block design storm; (b) 72-hour SW monsoon design storm with the 24-hour design depth on the final day. Illustrative depths only. Original drawing for this Manual. The alternating-block method follows Chow, Maidment & Mays, Applied Hydrology (1988), §14.4.

2.9.3 Other temporal patterns. Huff-type or mass-curve patterns derived from Odisha storms may be used instead of 2.9.1 and 2.9.2 only after they are published in Annex 2D. SCS Type I, IA, II and III distributions shall not be used.

2.9.4 Large catchments. For catchments of 25–5,000 km², the CWC Flood Estimation Report time-distribution curves may be used, and a sensitivity run with 2.9.1 shall be reported.

Commentary. The alternating-block storm embeds every shorter-duration design intensity in one hyetograph. That makes it conservative and consistent across durations. The 72-hour pattern puts the most intense day last. This reproduces the Odisha monsoon sequence: in August 1982 the heaviest falls in the Mahanadi basin came on 19 and 30 August, in a month that became the wettest on record at Sambalpur and Phulbani, and by the time they arrived the pokharis, paddy fields and deltaic soils were full and Hirakud was releasing into a rising river. The same sequence fills the reservoirs and the uncontrolled tributaries whose flows then govern the river tailwater at Cuttack, and in the cyclone months a storm that arrives after days of rain meets outfalls already held up by surge or by the river. SCS distributions are excluded because they come from US convective and Gulf storm data and have no basis in Odisha records.


2.10 Retention rainfall depth

2.10.1 The retention design depth is the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record, read from the zone value in Annex 2E.

2.10.2 The site must retain on site the runoff from this depth (Chapter 4). Retention earns a detention credit equal to the reduction in required detention storage found by routing with the retention in place (Clause 4.4.6). The credit is not the retained volume subtracted one-for-one.

Commentary. This follows the Kansas City Metro APWA 5600 (2025.01) Required Retention Volume concept and Georgia's 1.0-inch runoff reduction standard. Both are based on percentile storms. A percentile depth is a statistic of everyday rainfall, not an AEP value, so it is computed from the daily record rather than from the frequency curves.


2.11 Design storms for pre- and post-development comparison

2.11.1 Same storm for both scenarios. Pre- and post-development runs shall use the same design storms:

  • same AEP, duration, temporal pattern and climate factor;
  • same antecedent moisture condition (Clause 2.11.4).

The two runs differ only in land surface parameters and Tc.

2.11.2 Standard catchments. For each of the 50%, 10% and 1% AEP storms and each duration in Clause 2.5.2:

Q_post(T) ≤ 0.9 × Q_pre(T)

2.11.3 Flood-sensitive catchments (as listed in Chapter 4: the Gangua and Daya catchments of Bhubaneswar, Cuttack between the Mahanadi and the Kathajodi, Puri, Paradip and the tidal tract of the Mahanadi delta, Balasore and the tidal tract of the Budhabalanga–Baitarani delta, and Berhampur and the Gopalpur coast, and any catchment notified by the authority). The mixed-frequency rule applies:

Q_post(1% AEP, 100-yr) ≤ Q_pre(10% AEP, 10-yr), and Q_post(50% AEP, 2-yr) ≤ Q_pre(50% AEP, 2-yr),

The post-development peak is checked for each duration in Clause 2.5.2. The caps are taken at the pre-development critical duration. The 10-yr cap is the largest pre-development 10-yr peak over all durations, and the 2-yr cap is the largest pre-development 2-yr peak over all durations. Each cap applies to every post-development duration.

2.11.4 Antecedent moisture. Use AMC III (wet conditions) for every design storm, whatever its duration, of July–October at a site on the coastal plains and deltas, in zone OD-Z1 (North coast), OD-Z2 (Mahanadi–Brahmani delta and central coast) or OD-Z3 (South coast and Chilika) of Annex 2A, and of August–September at a site in zone OD-Z4 (Central Mahanadi basin) or OD-Z5 (Northern plateau). Use AMC III also for every design storm that represents a named cyclone, in any zone and month, including the cyclones of May. In zone OD-Z6 (Eastern Ghats and southern highlands), use AMC III for a design storm that follows, or contains, a 3-day rainfall total of more than 100 mm. Use AMC II (average conditions) for every other storm, including those of June across the State.

2.11.5 Pre-development condition. Pre-development is defined in Chapter 3: greenfield, open land in good condition for the mapped hydrologic soil group. Existing impervious cover is not counted as pre-development.

Commentary. Matching each site's post-development peak to its own pre-development peak does not protect the catchment. Denver's analysis found that 100% matching at every site still produced 106% of historic peak downstream, which led to the 90% rule. The mixed-frequency rule is stricter. It caps the 100-yr post-development release at what the undeveloped site produced in a 10-yr storm. Malaysia (DID 2008: all ARIs ≤ pre-development 2-yr) is a tropical precedent for this kind of cap. AMC III for long storms reflects that SW monsoon extremes arrive after weeks of rain. In Odisha this holds for short storms too on the coast and in the deltas. The deltaic alluvium of Cuttack, Kendrapara, Jagatsinghpur and Puri has a water table within about 0.1–1 m of the surface in places after the monsoon (CGWB district brochures, November 2011), and the CWC design loss rates are low, as they would be on saturated soils: in subzone 3(d) a curve falling from about 3.5 mm/h for a 3-hour storm to 1.5 mm/h for storms of about 13 hours or more, and 2.7 mm/h in 1(g) (CWC, 1997; CWC, 1994). The 4(a) rate of 7.5 mm/h rests mostly on catchments outside Odisha and is probably high for Ganjam (CWC, 1987). The October and May cyclones come with days of rain from the same system and the surge that closes the outfalls, and the interior's largest storms, as in August 1982, come in August and September. This Manual therefore uses AMC III for every design storm of July–October on the coastal plains and deltas (zones OD-Z1 to OD-Z3), of August–September in the Central Mahanadi basin and the Northern plateau (OD-Z4 and OD-Z5), and of a named cyclone anywhere, and in the Eastern Ghats and southern highlands (OD-Z6) after a 3-day total of more than 100 mm, and AMC II otherwise (Clause 2.11.4). These are interim choices set by this Manual; no Odisha study has yet validated AMC classes against observed runoff.

Illustrative scale of the mixed-frequency rule. The values below are not design values. They assume a 2 ha site in the Mahanadi delta near Cuttack with 24-h depths of 200 mm (10-yr) and 350 mm (100-yr), SCS-CN runoff with Ia = 0.2S, and CN 70 pre-development and CN 92 post-development:

Table 2.3 — Illustrative scale of the mixed-frequency rule (not design values)

Case Runoff depth Runoff volume (2 ha)
Pre-development, 10-yr 24 h 111 mm 2,210 m³
Post-development, 100-yr 24 h 325 mm 6,500 m³

The post-development 100-yr storm generates about three times the runoff volume of the pre-development 10-yr storm. A peak-rate cap at the pre-development 10-yr level means most of the difference must be stored and released slowly, so storage of the order of 0.2 m³ per m² of site may be needed. For this reason the rule applies only in flood-sensitive catchments (Clause 2.11.3); elsewhere the 0.9 × Q_pre rule of Clause 2.11.2 applies.


2.12 Joint occurrence with tailwater

2.12.1 For outfalls under tidal or river backwater influence, the design rainfall of this chapter shall be combined with the tailwater conditions of Chapter 5 as follows. The more severe case governs.

  • (a) Design rainfall (AEP as required) with a mean high water springs (MHWS) tailwater plus the sea-level allowance.
  • (b) A 10% AEP (10-yr) 48-hour storm with the 1% AEP still-water level (tide plus surge) plus the sea-level allowance.

Bhubaneswar drains east and south: eight of the ten natural drains of the city's development plan outfall to the Gangua nala, which the Khordha Drainage Division of DoWR manages, and the Gangua joins the Daya, which flows to Chilika (CAG, 2024). Cases (a) and (b) are therefore run at every outfall to the Gangua, the Daya West Canal, the Daya and the Kuakhai, with the tailwater of Chapter 5: the stage of the Kuakhai and the Daya when the Mahanadi is in flood, with the hydraulic gradient of the Gangua, and the level of Chilika for the southern outfalls. No DoWR design tailwater for these outfalls was found in research for this Manual [TBC]. Cuttack lies between the Mahanadi and the Kathajodi inside river embankments, and its main storm water channels outfall to the rivers through sluices, the Petta nala through six vented sluices into the Kathajodi (CAG, 2024). Its outfalls are river-locked, not tide-locked: they close when the river stage rises, with flows of 25,000–45,000 m³/s in the delta at Mundali in the large floods of 1980–2008 (Parhi et al., 2012). For Cuttack the tailwater in both cases is the river stage of Chapter 5, not the sea, and the storage and pumping behind the sluices must carry the city through a river peak that lasts for days. At Paradip, Puri, Gopalpur, Chandbali and Dhamra the tailwater is the sea or a tidal estuary. INCOIS puts the tidal maximum at Paradip at 1.21 m and the 100-year extreme sea level at 2.62 m above mean sea level (INCOIS, 2025); MHWS and HAT at Paradip, False Point, Dhamra, Gopalpur and Puri were not found in research for this Manual and are to be taken from the tide tables of the port or of the National Hydrographic Office [TBC]. Levels are taken on a stated datum (chart datum, mean sea level or the GTS bench mark; at Paradip the GTS bench mark is 5.04 m above chart datum (PSMSL)), as Chapter 5 requires.

Commentary. On the Odisha coast the coincidence is on record. Yaas crossed the coast near Balasore on 26 May 2021, the full-moon day, and a surge of about 2–4 m above the astronomical tide inundated the low-lying land of Balasore and Bhadrak districts, where IMD put the tidal wave of that day at 3 to 5 m (IMD, 2021). In the super cyclone of October 1999, estimates of the surge range from 5.9 m (a model run that Kalsi judges closest to the official estimates) to 7.95 m, while the heaviest rain of the storm fell in the same days (Kalsi, 2006). Phailin (2013) raised a surge of 2–2.5 m in Ganjam, Fani (2019) about 1.5 m near Puri, and Dana (2024) 1–2 m in Kendrapara, Bhadrak and Balasore (IMD). INCOIS puts the tidal maximum at Paradip at 1.21 m and the 100-year extreme sea level at 2.62 m above mean sea level, rising to 3.12 m (SSP2-4.5) or 3.34 m (SSP5-8.5) by 2100 (INCOIS, 2025); INCOIS itself states that its Paradip value is "much lower" than an earlier study's and probably underestimates the northern Bay, and it is below every estimate of the 1999 surge. Mean sea level at Paradip rose by about 2.95 mm a year over 1967–2024, by NEER's own fit to the PSMSL annual series, which PSMSL does not list as a trend; it is a screening figure only (PSMSL). MHWS and HAT at Paradip, False Point, Dhamra, Gopalpur and Puri were not found [TBC]. River and rain coincide too: at Cuttack the outfalls close when the Mahanadi rises, and in September 2011 about 13.66 lakh cusecs (about 38,700 m³/s) passed Mundali after Hirakud opened its gates (as reported). The levels of the sources are on different datums, which is why Chapter 5 requires every level to name its datum. Because rainfall and surge share a weather cause (the cyclones of the Bay of Bengal that bring the heaviest coastal rain also drive the surge: the super cyclone of October 1999 raised a surge estimated at 5.9 m or more at Erasama while 400–955 mm of rain fell in four days over the northern delta (Kalsi, 2006), and Yaas struck in May 2021 on the full-moon day), they cannot be treated as independent. Case (b) is a simple joint-probability surrogate until a statistical joint analysis is adopted.


2.13 Submittal requirements

Every hydrologic submittal shall include a Design Rainfall Sheet (Form 2-1) stating:

  1. the site coordinates and zone;
  2. the source (Clause 2.3), version or access date, and a screenshot or export of the values extracted;
  3. a depth table for each AEP and duration used, before and after the fixed-interval factor, grid-to-point factor, ARF and climate factor;
  4. the cross-check values of Clause 2.3.3 and the floor check;
  5. the hyetographs used, as a table and a plot, for each design storm; and
  6. the AMC and pre-development definition adopted.

Figure 2.3 shows the steps of this chapter in the order in which the sheet records them.

Figure 2.3 — From design rainfall source to design storm Seven steps in sequence: choose the approved source; set AEPs and durations; point depth for each AEP and duration; grid to point and areal reduction; climate factor; temporal pattern; design storm. A side panel lists what Form 2-1 records, and a second panel shows that the retention depth takes a separate route without the climate factor. From design rainfall source to design storm Steps a designer follows in Chapter 2, with the governing clause (schematic flowchart) 1 Choose the approved source Cl. 2.3 NIH-DHAARA at the site coordinates. Station IDF only with ≥ 30 yr record within 10 km; the greater value governs. Report the IMD (Das et al. 2022) cross-check; CWC subzone value is a floor for 25–5,000 km². 2 Set the AEPs and durations Cl. 2.4–2.5 AEP for each element from Table 2.1. Conveyance: duration = Tc, not less than 10 min. Storage: every duration in {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48, 72 h always. 3 Point depth for each AEP and duration Cl. 2.6 Read the depth from the source for each duration. If only daily depths exist, use the Annex 2B ratios (not the one-third rule). Fixed-interval data × 1.13 / 1.04 / 1.02 for 1 / 2 / 3–4 intervals. 4 Grid to point, then areal reduction Cl. 2.7 Grid-average values × grid-to-point factor (Annex 2C). ARF = 1.0 up to 10 km²; CWC curves above 25 km², linear between. No ARF for storage on a single development site. 5 Apply the climate factor Cl. 2.8 × 1.20 for durations ≤ 6 h; × 1.10 for > 6 h to 72 h. CF = 1.0 for temporary works (design life ≤ 5 years). Not applied to the retention depth or the WQv depth. 6 Build the temporal pattern Cl. 2.9 ≤ 24 h: alternating block, peak at 50%, time step ≤ Tc/3 and ≤ 15 min. 48 / 72 h: the 24 h design depth in the final 24 h; the remainder spread uniformly before it. SCS Type I, IA, II and III are not permitted. 7 Design storm (hyetograph) Cl. 2.11–2.12 Same storms for pre- and post-development runs. AMC II for storms ≤ 6 h; AMC III for 12 h and longer. Tidal or backwater outfalls: also run the joint cases of Clause 2.12. Form 2-1 Design Rainfall Sheet (Cl. 2.13) records: 1. Site coordinates and zone 2. Source, version or access date, export 3. Depth table before and after each factor (steps 3–5) 4. Cross-checks and the CWC floor 5. Hyetographs: table and plot (steps 6–7) 6. AMC and pre- development condition Retention depth (separate route) 90th percentile wet-day (≥ 2.5 mm) 24 h depth, zone value from Annex 2E. No climate factor, no hyetograph for sizing the volume. Cl. 2.10, 2.8.3 Schematic flowchart. Clause numbers refer to Chapter 2. The order of steps 3–5 is the order of the columns of the depth table on Form 2-1.

Figure 2.3 — From design rainfall source to design storm: the steps a designer follows (source, AEPs and durations, point depth, grid-to-point and areal reduction, climate factor, temporal pattern, design storm), the clause that governs each step, what Form 2-1 records, and the separate route for the retention depth. Schematic. Original drawing for this Manual.


2.14 Review and update

2.14.1 The approving authority shall review this chapter every 10 years. It shall also review it within 2 years of any event in which recorded rainfall exceeds the 1% AEP 24-hour or 72-hour design depth at two or more approved gauges in the State.

2.14.2 Updates to NIH-DHAARA take effect for new submittals 6 months after release, unless the authority notifies otherwise.


References (chapter)

Annexes

Annex Content
2A NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map
2B Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule
2C Grid-to-point factors
2D Odisha temporal patterns (Huff curves)
2E Retention percentile depths by zone
Form 2-1 Design Rainfall Sheet