Annexes to Chapter 2Design Rainfall and Design Storms
These annexes support Chapter 2. Annexes 2A to 2E will hold the statewide rainfall tables that Chapter 2 refers to: the benchmark checks and zone map, sub-daily ratios, grid-to-point factors, temporal patterns and retention depths. Each needs analysis of NIH-DHAARA and IMD records that has not yet been done for this Manual, so each is marked "To be prepared" and gives its intended layout and the rule to use until it is published (Clause 1.11.5). Form 2-1 is a draft form for the Design Rainfall Sheet that every hydrologic submittal must include (Clause 2.13). The Manual is a draft; it is not adopted by any government or agency.
Annex 2A — NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map
Supports Clauses 2.3.1 to 2.3.5 of Chapter 2.
To be prepared. This annex will compare, at benchmark points across the State, the NIH-DHAARA design depths with frequency analyses of long IMD daily station records and of IMD gridded daily data (converted to point values with Annex 2C), for 24 hours and longer and for the AEPs of Table 2.1. It will also contain the map of rainfall zones used by Annexes 2B, 2C and 2E and by the Tier B tables of Chapter 4. It needs NIH-DHAARA values at the benchmark coordinates (NIH), IMD daily and recording-gauge station records and IMD gridded rainfall (IMD), State rain-gauge records (the tehsil rain gauges whose readings IMD reports, the gauges of I&WRD and any network of UPSDMA [TBC]), and district and basin boundaries (Survey of India, I&WRD). Until it is published, design depths are taken from NIH-DHAARA under Clause 2.3.1, the cross-checks of Clause 2.3.3 are reported on Form 2-1, and the zone of a site is the one agreed with the Authority and recorded on Form 2-1.
Table 2A.1 — Benchmark comparison of design depths (layout)
| Benchmark point | IMD station ID | Latitude, longitude | Years of record | Duration (h) | AEP | NIH-DHAARA (mm) | IMD station analysis (mm) | IMD gridded, point value (mm) | NIH-DHAARA / IMD station | Remarks |
|---|---|---|---|---|---|---|---|---|---|---|
| 24 | ||||||||||
| 48 | ||||||||||
| 72 |
2A.1 The zone names below are the working names used in the Tier B table template of Chapter 4 (Clause 4.14.2). Their boundaries, and whether further zones are needed, are to be set by the analysis of this annex.
Table 2A.2 — Rainfall zones (layout)
| Zone (working name) | Extent (districts, basins) | Representative stations | Notes |
|---|---|---|---|
| UP-Z1 West | The west of the State in CWC subzone 1(e), from Saharanpur, Muzaffarnagar, Shamli, Baghpat, Meerut, Hapur, Ghaziabad, Gautam Buddh Nagar and Bulandshahr to Aligarh, Hathras, Mathura, Agra, Firozabad, Etah, Mainpuri and Etawah, with the strip of subzone 1(b) along the last 46 km of the Chambal in the ravines of Agra and Etawah; boundary with UP-Z2 on the 1(e)/1(f) boundary of the 1(f) report's Plate 8 [TBC] | Agra 42261 (daily record 1901–2012), Aligarh 42262 (from 1931), Meerut 42139 (from 1901), Mainpuri 42265; for Ghaziabad and Gautam Buddh Nagar, which have no long-record IMD station, New Delhi/Safdarjung 42182, the nearest (Clause 2.3.6(e)) | Annual normals about 690–790 mm (Agra 693.6, Meerut 788.9 mm), JJAS 82–87% (IMD). FER 1(e) 50-yr 24-h about 200–280 mm, typically about 240 mm (Plate 9; Agra 200–240, Ghaziabad and Noida 220–240, Meerut about 280); 1-h ratio 0.34 (1(e)) and 0.35 (1(b)). Floors of Clause 2.3.6(h): 1 h 70–100 mm and 3 h 110–165 mm at 10–100 yr. Records: Aligarh 327.2 mm (30 Jun 1981), Agra 286.0 mm (16 Sep 1939), Meerut 227.3 mm (17 Sep 1880) (IMD); Ghaziabad 143–164 mm in one night on 9 Jul 2026 (as reported). NIH-DHAARA 50-yr 24-h low here (Noida 204, Ghaziabad 218, Meerut 215 mm) |
| UP-Z1 West: UP-A West doab and NCR | As UP-Z1; the doab between the Yamuna and the Ganga, the NCR districts and the Yamuna and Hindon floodplains | As UP-Z1 | Alluvium with a deep water table in the cities (Ghaziabad 22.8 m below ground in 2006; Bisrakh in Gautam Buddh Nagar and blocks of Ghaziabad over-exploited, as reported). Receiving waters: the Yamuna (Mathura HFL 169.73 m, Agra 154.76 m, both 1978) and the Hindon (197.28 m at Noida on 26 Jul 2023, 1.81 m above the old HFL), as reported. Recharge-first where the water table is deep; Hindon and Yamuna backwater in the low sectors of Noida and Ghaziabad |
| UP-Z2 Central–east plain and Bundelkhand | The central and eastern Ganga plain in subzone 1(f), and Bundelkhand and the Vindhyan south in subzones 1(c) and 1(d) | Lucknow City 42368 (1901–2010) and Lucknow/Amausi 42369 (from 1951), Kanpur 42366, Allahabad/Bamhrauli 42475 (from 1886), Varanasi (BHU) 42483 and Varanasi/Babatpur 42479, Fatehpur 42471, Sultanpur 42375, Jhansi 42463, Banda 42473, Orai 42468 | Annual normals about 830–990 mm (Jhansi 831.2, Lucknow 861.4, Prayagraj 915.4, Varanasi 985.9 mm), JJAS 87–90% (IMD). FER 50-yr 24-h about 220–320 mm (Kanpur 220–240, Lucknow and Varanasi 240–280, Prayagraj 280–320, Jhansi and Banda 240–280, Lalitpur more than 320); 1-h ratio 0.31 (1(f)) and 0.32 (1(c)). Lucknow station fit (Kathuria, Kaur & Mehra, 1987): 50-yr 1 h 106.0, 3 h 174.6, 6 h 233.5 mm. Floors of Clause 2.3.6(h): 1 h 80–115 mm and 3 h 130–195 mm at 10–100 yr. Records: Varanasi (BHU) 349.5 mm (26 Sep 1943), Allahabad 335.3 mm (20 Aug 1953), Lucknow 311.7 mm (17 Jul 1947), Kanpur 242.8 mm (16 Sep 1970), Jhansi 266.7 mm (12 Aug 1952); Khajwa (Fatehpur) 514.9, Meja (Allahabad) 512.1 and Derapur (Kanpur) 508.0 mm before 1920 (IMD) |
| UP-Z2 Central–east plain and Bundelkhand: UP-B Central–east Ganga plain | Lucknow, Kanpur, Unnao, Rae Bareli, Hardoi, Sitapur, Barabanki, Ayodhya, Sultanpur, Pratapgarh, Prayagraj north of the Yamuna, Fatehpur, Kaushambi, Varanasi, Jaunpur, the north of Chandauli, Ghazipur, Mau, Azamgarh and Ballia, and the districts between them; boundaries [TBC] | Lucknow, Kanpur, Bamhrauli, Babatpur and BHU, as UP-Z2 | Older alluvium (bangar) with kankar, and usar (sodic) patches; khadar along the rivers. Lucknow city over-exploited, water table 7.65–45.6 m below ground before the 2023 monsoon (CGWB). Receiving waters, as reported: the Gomti at Lucknow (HFL 110.85 m, 1971), the Ganga at Kanpur (114.08 m, 2010), Phaphamau (87.98 m, 1978) and Varanasi (73.901 m, 1978), the Yamuna at Naini (87.99 m, 1978), the Sai, the Varuna and the Assi. Embanked Gomti in Lucknow with pumped outfalls |
| UP-Z2 Central–east plain and Bundelkhand: UP-E Bundelkhand and Vindhyan | Jhansi, Lalitpur, Jalaun, Hamirpur, Mahoba, Banda and Chitrakoot (subzone 1(c)), and Sonbhadra, the south of Mirzapur and Chandauli and Prayagraj south of the Yamuna (subzone 1(d), report not found [TBC]); boundaries [TBC] | Jhansi 42463, Banda 42473, Orai 42468 | Granite and granite-gneiss with thin red and black soils, and Vindhyan sandstone, limestone and shale; groundwater only in the weathered and fractured zone (CGWB, as reported). Fast runoff, low base flow (FER 1(c) 0.018 m³/s/km²). Lalitpur flagged: 50-yr 24-h more than 320 mm on 1(c) Plate 10; Lalitpur 384.0 mm (10 Sep 1941) (IMD). Rivers: the Betwa, the Ken, the Yamuna, the Son and the Kanhar |
| UP-Z3 Terai and Rohilkhand | The terai and foothill belt along the Nepal and Uttarakhand borders and the Rohilkhand plain, in subzone 1(f) in the north-east and 1(e) and 1(f) in the north-west | Gorakhpur 42379 (1901–2012), Bahraich 42273, Bareilly 42189, Moradabad 42187, Najibabad 42143, Kheri Lakhimpur 42270, Shahjahanpur 42266, Nautanwa 42282; Gonda 42274 (1931–93) | Annual normals about 1,190–1,240 mm (Bareilly 1,186.5, Bahraich 1,198.6, Gorakhpur 1,240.9 mm), JJAS 85–88% (IMD). FER 50-yr 24-h from about 240 mm to more than 400 mm (Gorakhpur and Bareilly about 240–280, Gonda about 320, Lakhimpur more than 320, more than 400 on the Nepal border). Floors of Clause 2.3.6(h) as UP-Z2; the ratio floor governs where the 24-h depth is large. Records: Gonda 487.2 mm (12 Jun 1984), Bahraich 463.3 mm (13 Sep 1982), Baheri 460.6 mm (8 Jul 2024), Najibabad 425.0 mm (22 Jul 2010) (IMD). NIH-DHAARA 50-yr 24-h high here at the city cells (Gorakhpur 380, Bahraich 500, Bareilly 390 mm) |
| UP-Z3 Terai and Rohilkhand: UP-C North-east terai | Bahraich, Shrawasti, Balrampur, Gonda, Siddharthnagar, Basti, Sant Kabir Nagar, Maharajganj, Gorakhpur, Kushinagar and Deoria; boundaries [TBC] | Gorakhpur, Bahraich, Gonda, Nautanwa | Newer alluvium and terai deposits; shallow water table, wells flowing under artesian pressure in the terai (CGWB, as reported). June already wet (Gorakhpur 187.8, Bahraich 180.8 mm). Receiving waters: the Rapti at Birdghat (HFL 77.54 m, 1998), the Ghaghra, the Rohin and Ramgarh Tal, as reported. Long river-locked periods behind the Rapti and Rohin embankments |
| UP-Z3 Terai and Rohilkhand: UP-D Rohilkhand and western terai | Bijnor, Moradabad, Rampur, Bareilly, Pilibhit, Shahjahanpur, Lakhimpur Kheri and Budaun; boundaries [TBC] | Bareilly, Moradabad, Najibabad, Kheri Lakhimpur, Shahjahanpur | From the coarse bhabar fringe with a deep water table to the terai with a shallow one (CGWB, as reported); waterlogging in the Sharda Sahayak command (as reported). Steep foothill streams, for which the 1(e) report asks for a "suitable increase". Receiving waters: the Ramganga (Moradabad HFL 192.88 m, 2010), the Sharda and the head of the Gomti, as reported |
Annex 2B — Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule
Supports Clauses 2.6.1 to 2.6.4 of Chapter 2.
To be prepared. This annex will tabulate, for each zone of Annex 2A, the ratios of the t-hour to the 24-hour design depth from NIH-DHAARA, which are derived from hourly records, against the ratios implied by IMD Das et al. (2022) and by the one-third rule. It needs NIH-DHAARA depths for each duration at representative points in each zone (NIH), IMD recording-gauge data and the IDF values of Das et al. (2022) (IMD). Until it is published, sub-daily depths are read directly from NIH-DHAARA or an approved station IDF (Clause 2.6.1). Where only daily depths are available, the ratios used are those agreed with the Authority, which in Uttar Pradesh are those of Clause 2.3.6: the CWC Flood Estimation Report ratios for the site's subzone in Table 2B.1, raised at 1 and 3 hours to the floors of Clause 2.3.6(h) for the 10-yr and rarer storms, and, in the development area of LDA, not less than the Lucknow station values of Clause 2.3.6(b) (Clause 2.6.2), and are recorded on Form 2-1. The one-third rule is not used (Clause 2.6.4).
2B.1 The first row of Table 2B.1 gives the ratios of the one-third rule P(t) = P(24)·(t/24)^(1/3), for comparison only. The 1, 3, 6 and 12 h values are those stated in the commentary to Clause 2.6; the 2 h value is computed from the same formula. The rule shall not be used for design unless this annex confirms it for the zone concerned (Clause 2.6.4).
Table 2B.1 — Ratios P(t)/P(24h) by zone (layout)
| Zone | Source | 1 h | 2 h | 3 h | 6 h | 12 h | 24 h |
|---|---|---|---|---|---|---|---|
| All (reference only, not for design) | One-third rule | 0.35 | 0.44 | 0.50 | 0.63 | 0.79 | 1.00 |
| UP-Z1 West, and the 1(e) part of UP-Z3 (UP-D) | CWC FER 1(e), 50-yr (interim design ratios, Clause 2.3.6(g)) | 0.340 | 0.475 | 0.560 | 0.680 | 0.840 | 1.00 |
| UP-Z1 West: Chambal strip of Agra and Etawah | CWC FER 1(b), 50-yr (interim design ratios, Clause 2.3.6(g)) | 0.35 | 0.53 | 0.67 | 0.80 | 1.00 | |
| UP-Z2 (UP-B) and the 1(f) part of UP-Z3 (UP-C, UP-D) | CWC FER 1(f), 50-yr (interim design ratios, Clause 2.3.6(g); 2-h value from an OCR of Fig. 10 [TBC]) | 0.31 | 0.425 | 0.50 | 0.65 | 0.82 | 1.00 |
| UP-Z2 (UP-E), and the 1(d) area | CWC FER 1(c), 50-yr (interim design ratios, Clause 2.3.6(g)) | 0.32 | 0.50 | 0.65 | 0.79 | 1.00 | |
| All zones | Ratio floor of Clause 2.3.6(h)(i), 10–100 yr | 0.35 | 0.57 | 1.00 | |||
| UP-Z2 (UP-B): Lucknow | Kathuria, Kaur & Mehra (1987), 2-yr station ratios (comparison only; 6-h ratio 0.71) | 0.36 | 0.58 | 0.71 | 1.00 | ||
| UP-Z2 (UP-B): Kanpur | Kathuria, Kaur & Mehra (1987), 2-yr station ratios (comparison only) | 0.38 | 0.61 | 0.74 | 1.00 | ||
| UP-Z3 (UP-C): Bahraich | Kathuria, Kaur & Mehra (1987), 2-yr station ratios (comparison only) | 0.35 | 0.57 | 0.69 | 1.00 | ||
| UP-Z2 (UP-B): Lucknow | Station fit of Clause 2.3.6(b) at 50 yr, as ratios to a 24-h plate value of 280 mm (comparison only) | 0.38 | 0.62 | 0.83 | 1.00 | ||
| UP-Z2 (UP-B): Lucknow | NIH-DHAARA, 50-yr, Lucknow cell (comparison only; 3- and 6-hour values not queried) | 0.25 | 0.40 | 0.83 | 1.00 |
2B.2 Depths from fixed observation windows are converted to true-interval depths with the factors of Clause 2.6.3, repeated in Table 2B.2. They are the standard WMO (Hershfield) values and are not provisional.
Table 2B.2 — Fixed-interval adjustment factors (Clause 2.6.3)
| Number of fixed observation intervals in the duration | Factor |
|---|---|
| 1 | 1.13 |
| 2 | 1.04 |
| 3–4 | 1.02 |
Annex 2C — Grid-to-point factors
Supports Clauses 2.7.1 and 2.7.4 of Chapter 2.
To be prepared. This annex will give the factors that convert grid-average design depths (for example from 0.25° cells) to point depths, by zone, duration and AEP. It needs paired frequency analyses of IMD gridded rainfall and of the IMD and State gauges inside each cell (IMD, I&WRD and the tehsil rain gauges of the Revenue Department [TBC]), the benchmark points of Annex 2A, and a stated method for deriving the factors. Until it is published, design depths are taken as point values from NIH-DHAARA or an approved station IDF (Clauses 2.3.1 and 2.3.2). Grid-average values are not used as design depths unless a conversion agreed with the Authority is recorded on Form 2-1 (Clause 1.11.5).
2C.1 The commentary to Clause 2.7 shows why the factors matter, and in Uttar Pradesh the reanalysis cells err both ways. At Prayagraj the IMDAA cell of NIH-DHAARA (about 12 km) gives a 50-year 24-hour depth of about 265 mm and a 100-year depth of about 299 mm, while the Allahabad gauge recorded 335.3 mm on 20 August 1953; at Varanasi the cell gives about 254 mm and 286 mm, while Varanasi (BHU) recorded 349.5 mm on 26 September 1943. At Gorakhpur the cell's 50-year value, about 380 mm, is well above the station's record of 284.5 mm (19 August 1912), and at Bahraich its 50-year value of about 500 mm is above the station's record of 463.3 mm (13 September 1982). The cells' 50-year 1-hour depths, 63–109 mm, are 0.22–0.32 of their 24-hour depths, and at Lucknow 70.7 mm against 106.0 mm from the station fit (NIH-DHAARA, queried 6 Nov 2026; IMD; Kathuria, Kaur & Mehra, 1987). Values of this kind are grid-average values and need these factors before any use as point depths; under Clause 2.3.6 they are not used as design depths in Uttar Pradesh until this annex and Annex 2A are published.
Table 2C.1 — Grid-to-point factors (layout)
| Zone | Grid product and cell size | Duration (h) | AEP | Factor (point / grid) | Stations used | Years of record |
|---|---|---|---|---|---|---|
| 24 | ||||||
| 48 | ||||||
| 72 |
Annex 2D — Uttar Pradesh temporal patterns (Huff curves)
Supports Clauses 2.9.3 and 2.9.4 of Chapter 2, and Clause 11.7.3 of Chapter 11.
To be prepared. This annex will give dimensionless time-distribution (mass) curves of Uttar Pradesh storms, in the form introduced by Huff (1967), by zone, storm-duration class and quartile, at stated probability levels. It needs storm hyetographs from recording gauges and automatic weather stations (IMD, its automatic weather stations and automatic rain gauges in the State, and any recording gauges of I&WRD [TBC]), separated into independent storms by a stated rule, and the east Uttar Pradesh storm of 14–15 September 2022 (Gorakhpur and Jaunpur), the Lucknow storm of 15–16 September 2022, the storm of 10–11 September 2023 over Lucknow, Kanpur and Barabanki, the Baheri storm of 8 July 2024 and the Ghaziabad storm of 9 July 2026 among them. Until it is published, design storms use the alternating-block pattern of Clause 2.9.1 and the 48- and 72-hour pattern of Clause 2.9.2; for catchments of 25–5,000 km², the CWC Flood Estimation Report curves may be used with a sensitivity run under Clause 2.9.1 (Clause 2.9.4). SCS Type distributions are not used (Clause 2.9.3). For the disaggregation of daily records in continuous simulation (Clause 11.7.3), the method is agreed with the Authority and recorded (Clause 1.11.5).
Table 2D.1 — Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)
| Fraction of storm time | 0 | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 10% probability curve | 0 | 1.0 | |||||||||
| 50% probability curve | 0 | 1.0 | |||||||||
| 90% probability curve | 0 | 1.0 |
2D.1 Each table shall state the zone, the duration class, the quartile (the quarter of the storm in which most rain fell), the number of storms analysed and the period of record.
Reference: Huff, F.A. (1967). Time distribution of rainfall in heavy storms. Water Resources Research 3(4), 1007–1019.
Annex 2E — Retention percentile depths by zone
Supports Clauses 2.8.3 and 2.10.1 to 2.10.2 of Chapter 2, Clause 4.4 of Chapter 4 and Chapter 8.
To be prepared. This annex will give, for each zone of Annex 2A, the retention design depth P_R: the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record (Clause 2.10.1). It needs long daily records at stations in each zone (IMD, I&WRD and the tehsil rain gauges of the Revenue Department [TBC]) and IMD gridded data with the factors of Annex 2C where stations are sparse. Until it is published, P_R is computed by the definition of Clause 2.10.1 from the long-term daily record of a station agreed with the Authority, by the steps in 2E.1, and recorded on Form 2-1 (Clause 1.11.5).
2E.1 Computing P_R from a daily record.
- Take the daily (24-hour) rainfall series of the station for its full record.
- Keep only the days with rain of 2.5 mm or more (wet days).
- Rank the wet-day depths and take the depth not exceeded on 90% of them (the 90th percentile).
- Do not apply the climate factor (Clause 2.8.3) or the fixed-interval factor; P_R is a statistic of everyday rainfall, not an AEP design depth.
- Record the station, the period of record, the number of wet days and P_R on Form 2-1.
Table 2E.1 — Retention depth P_R by zone (layout)
| Zone | Stations or grid cells used | Period of record | Number of wet days (≥ 2.5 mm) | P_R, 90th percentile (mm) | Issued on |
|---|---|---|---|---|---|
| UP-Z1 West | |||||
| UP-Z2 Central–east plain and Bundelkhand | |||||
| UP-Z3 Terai and Rohilkhand |
Form 2-1 — Design Rainfall Sheet
Supports Clauses 2.3 to 2.13 of Chapter 2, and Clause 10.4.1(d) of Chapter 10.
Draft form — Uttar Pradesh Stormwater Design Manual, Draft v1.0. One sheet for each hydrologic submittal. The steps follow Figure 2.3 of Chapter 2.
Table 2F.1 — Form 2-1: site, source and storms
| No. | Item (clause) | Entry |
|---|---|---|
| A. Site (Clause 2.13, item 1) | ||
| A1 | Project and site | ______ |
| A2 | Site coordinates (latitude, longitude, decimal degrees) | ______ |
| A3 | Rainfall zone (Annex 2A, or as agreed with the Authority) | ______ |
| A4 | Contributing catchment area (km²) (Clause 2.7) | ______ |
| A5 | Design life: more than 25 years / temporary works, 5 years or less (Clause 2.8.2) | ______ |
| A6 | Outfall under tidal or river backwater influence: Yes / No (Clauses 2.5.3, 2.12) | ______ |
| B. Source (Clauses 2.3, 2.3.5; item 2) | ||
| B1 | NIH-DHAARA: version or access date | ______ |
| B2 | Coordinates queried | ______ |
| B3 | Screenshot or export of the values extracted attached: reference | ______ |
| B4 | Station IDF used (Clause 2.3.2): No / Yes — station, ID, distance from site (km) | ______ |
| B5 | Station IDF: years of recording-gauge data (30 or more); published or approved by | ______ |
| B6 | Station IDF: change of terrain or coastal exposure between gauge and site: None / describe | ______ |
| C. AEPs and durations (Clauses 2.4, 2.5) | ||
| C1 | Elements designed and their AEPs (Table 2.1) | ______ |
| C2 | Conveyance: Tc and design duration (not less than 10 min) (Clause 2.5.1) | ______ |
| C3 | Storage: durations checked from {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48 and 72 h included (Clause 2.5.2) | ______ |
| C4 | Critical duration found for each storage element | ______ |
| D. Conversions | ||
| D1 | Sub-daily depths: read directly / from Annex 2B ratios / from ratios agreed with the Authority (Clauses 2.6.1, 2.6.2) | ______ |
| D2 | Fixed-interval factor applied: none (true-interval source) / 1.13 / 1.04 / 1.02 (Clause 2.6.3) | ______ |
| D3 | Grid-to-point factor: not needed (point source) / Annex 2C / agreed value (Clause 2.7.1) | ______ |
| D4 | ARF: 1.0 (10 km² or less; single-site storage) / CWC curve / interpolated (Clauses 2.7.2–2.7.4) | ______ |
| D5 | Climate factor: 1.20 (≤ 6 h) and 1.10 (> 6–72 h) / 1.0 temporary works / projected depths under Clause 2.8.4 | ______ |
| E. Cross-checks (Clause 2.3.3; item 4) | ||
| E1 | IMD Das et al. (2022) values for 1–24 h: reported in Table 2F.2 | ______ |
| E2 | CWC subzone 1(e) / 1(f) / 1(c) / 1(b) 24-hour point value, catchments of 25–5,000 km²: subzone used | ______ |
| E3 | CWC floor governs for any AEP: No / Yes — AEPs | ______ |
| F. Retention depth (Clause 2.10) | ||
| F1 | P_R (mm) and source: Annex 2E zone value / computed under Annex 2E, 2E.1 — station and period | ______ |
| F2 | No climate factor applied to P_R (Clause 2.8.3): confirmed | ______ |
| G. Design storms (Clauses 2.9, 2.11, 2.12; items 5 and 6) | ||
| G1 | Storms up to 24 h: alternating block, peak at 50%; time step (≤ Tc/3 and ≤ 15 min) | ______ |
| G2 | 48 and 72 h storms: built under Clause 2.9.2 (Table 2F.3) | ______ |
| G3 | Other pattern used: none / Annex 2D / CWC FER with sensitivity run (Clauses 2.9.3, 2.9.4) | ______ |
| G4 | Hyetographs attached as a table and a plot for each design storm: reference | ______ |
| G5 | AMC: III for every design storm of 1 July–30 September in UP-C and UP-D and on floodplain or embanked low-lying land anywhere, and of July–August in UP-B, whatever its duration; in UP-A and UP-E, III for a storm that follows or contains a 5-day total of more than 53 mm; II otherwise (Clause 2.11.4) | ______ |
| G6 | Pre-development condition: greenfield, open land in good condition for the mapped HSG (Clause 2.11.5) | ______ |
| G7 | Release criterion: standard, Q_post ≤ 0.9 × Q_pre (Clause 2.11.2) / flood-sensitive, mixed-frequency rule (Clause 2.11.3) | ______ |
| G8 | Tailwater joint cases run (Clause 2.12): case (a) MHWS + sea-level allowance; case (b) 10% AEP 48 h storm with 1% AEP still-water level + sea-level allowance; governing case | ______ |
| H. Prepared by | ||
| H1 | I confirm that the values above are those extracted and used in the submittal. Name, registration number, signature, date | ______ |
Design depth = source depth × fixed-interval factor × grid-to-point factor × ARF × climate factor. Where the design depth is lower than the CWC floor for the same AEP, the floor is adopted (Clause 2.3.3).
Table 2F.2 — Form 2-1: depth table (Clause 2.13, item 3)
| AEP (T-yr) | Duration | Source depth (mm) | Fixed-interval factor | Grid-to-point factor | ARF | Climate factor | Design depth (mm) | IMD Das et al. (2022) (mm) | CWC floor (mm) | Adopted depth (mm) |
|---|---|---|---|---|---|---|---|---|---|---|
Table 2F.3 — Form 2-1: 48- and 72-hour storm construction (Clause 2.9.2)
| AEP (T-yr) | Duration (h) | Total design depth (mm) | 24 h design depth, final 24 h (mm) | Remainder (mm) | Hours before the final 24 h | Uniform intensity before the final 24 h (mm/h) |
|---|---|---|---|---|---|---|
| 48 | 24 | |||||
| 72 | 48 |