Annexes to Chapter 2Design Rainfall and Design Storms
These annexes support Chapter 2. Annexes 2A to 2E will hold the statewide rainfall tables that Chapter 2 refers to: the benchmark checks and zone map, sub-daily ratios, grid-to-point factors, temporal patterns and retention depths. Each needs analysis of NIH-DHAARA and IMD records that has not yet been done for this Manual, so each is marked "To be prepared" and gives its intended layout and the rule to use until it is published (Clause 1.11.5). Form 2-1 is a draft form for the Design Rainfall Sheet that every hydrologic submittal must include (Clause 2.13). The Manual is a draft; it is not adopted by any government or agency.
Annex 2A — NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map
Supports Clauses 2.3.1 to 2.3.5 of Chapter 2.
To be prepared. This annex will compare, at benchmark points across the State, the NIH-DHAARA design depths with frequency analyses of long IMD daily station records and of IMD gridded daily data (converted to point values with Annex 2C), for 24 hours and longer and for the AEPs of Table 2.1. It will also contain the map of rainfall zones used by Annexes 2B, 2C and 2E and by the Tier B tables of Chapter 4. It needs NIH-DHAARA values at the benchmark coordinates (NIH), IMD daily and recording-gauge station records and IMD gridded rainfall (IMD), State rain-gauge records (the district rain gauges whose readings IMD tabulates in the Climate of Uttarakhand, the gauges of the Irrigation Department, of UJVN Ltd and of THDC at their barrages and dams, and the observatory of G.B. Pant University of Agriculture and Technology at Pantnagar [TBC]), and district and basin boundaries (Survey of India, Irrigation Department). Until it is published, design depths are taken from NIH-DHAARA under Clause 2.3.1, the cross-checks of Clause 2.3.3 are reported on Form 2-1, and the zone of a site is the one agreed with the Authority and recorded on Form 2-1.
Table 2A.1 — Benchmark comparison of design depths (layout)
| Benchmark point | IMD station ID | Latitude, longitude | Years of record | Duration (h) | AEP | NIH-DHAARA (mm) | IMD station analysis (mm) | IMD gridded, point value (mm) | NIH-DHAARA / IMD station | Remarks |
|---|---|---|---|---|---|---|---|---|---|---|
| 24 | ||||||||||
| 48 | ||||||||||
| 72 |
2A.1 The zone names below are the working names used in the Tier B table template of Chapter 4 (Clause 4.14.2). Their boundaries, and whether further zones are needed, are to be set by the analysis of this annex.
Table 2A.2 — Rainfall zones (layout)
| Zone (working name) | Extent (districts, basins) | Representative stations | Notes |
|---|---|---|---|
| UK-Z1 Plains and foothills | The plains below the Siwalik front, in CWC subzone 1(e), the Upper Indo-Ganga Plains (Clause 2.3.6(b)): Haridwar district and the bhabar–terai of Pauri, Nainital, Udham Singh Nagar and Champawat; catchments that cross a zone line take the higher zone value, and towns on the front (Kathgodam, Kotdwara, Ramnagar, the northern wards of Haridwar) compute both reports and take the higher | Roorkee 42140 (daily record 1901–2012); district gauges with 33–35 years of data in IMD's district tables: Haldwani, Kashipur, Khatima, Rudrapur/Kichha, Bazpur, Kaladhungi, Bambasa; the Pantnagar observatory (16 years in the same table [TBC]) | District normals about 1,070–1,200 mm (Udham Singh Nagar 1,071.1, Hardwar 1,202.9 mm), gauges up to 1,747.4 mm at Haldwani (IMD). FER 1(e) 50-yr 24-h about 280 mm at Haridwar–Roorkee rising to 400–440 mm at Haldwani–Kathgodam, the wettest cell of the 1(e) plates; 1-h ratio 0.34, with the floors of Clause 2.3.6(g). Records that qualify under Clause 2.3.6(h): Khatima 405.6 mm (15 Sep 1972) and Haldwani 413.0 mm (11 Jul 1970) (IMD). October storms (Kashipur 315.0 mm, 2 Oct 1954; Ramnagar 291.0 mm, 14 Oct 1985; Pantnagar 403.9 mm, 19 Oct 2021). NIH-DHAARA 50-yr 24-h high here (about 400 mm at Haldwani, Kashipur and Rudrapur; 358 mm at Haridwar) |
| UK-Z1 Plains and foothills: UK-B Haridwar–Roorkee plains | Haridwar (with BHEL and SIDCUL), Jwalapur, Kankhal, Roorkee, Laksar, Manglaur, Bhagwanpur and Bahadrabad; Roorkee and the west of the sub-area lie in UTM zone 43N; boundaries [TBC] | Roorkee 42140; the Hardwar and Roorkee district gauges (34 and 41 years of data) | FER 50-yr 24-h about 280 mm, 100-yr 280–320 mm with a spot of 311 mm. Records: Roorkee (Obsy) 266.7 mm (20 Sep 1888) and 237.7 mm (25 Jul 1966); Hardwar (Hydro) 495.3 mm (18 Sep 1880), the State's highest day, and Roorkee 284.7 mm (17 Sep 1880), excluded under Clause 2.3.6(h) as records made before 1901 until IMD confirms their gauges [TBC]; no qualifying record raises the plates here (IMD). The bhabar fringe at Bhagwanpur, with water up to about 70 m deep, and Ganga alluvium to the south, with the first aquifer 4–8 m below ground; Bahadrabad and Bhagwanpur semi-critical (CGWB, 2020 and 2022). Receiving waters: the Ganga at Haridwar (CWC warning 293.0 m, danger 294.0 m, highest level 296.30 m, 2010 or 2013) and the Bhimgoda barrage; the Upper Ganga Canal; the Solani at Roorkee (warning 260.5 m, danger 261.5 m, highest level 260.58 m, 14 Oct 2021) |
| UK-Z1 Plains and foothills: UK-C Bhabar–terai (Haldwani–Kashipur–Rudrapur–Kotdwara) | Haldwani–Kathgodam, Lalkuan, Kaladhungi, Ramnagar, Kashipur, Jaspur, Bazpur, Gadarpur, Rudrapur, Kichha, Pantnagar, Sitarganj, Khatima, Tanakpur–Banbasa and Kotdwara; boundaries [TBC] | Haldwani (35 years of data), Kashipur (34), Khatima (33), Rudrapur/Kichha (33), Bambasa (35); the Pantnagar observatory [TBC]; Mukteswar 42147 above the front | FER 50-yr 24-h about 400–440 mm at Haldwani–Kathgodam (100-yr 440–480 mm, a spot of 490 mm north-west), 320–360 mm at Ramnagar, about 320 mm at Khatima and Tanakpur [TBC], and 280–320 mm at Kotdwara, Kashipur and Rudrapur. Records: Khatima 405.6 mm (15 Sep 1972), qualifying, for Khatima, Banbasa and Tanakpur; Haldwani 413.0 mm (11 Jul 1970), qualifying, below the plate at Haldwani but raising Pantnagar; Bambasa 340.0 mm (10 Jul 1990); Kashipur 315.0 mm (2 Oct 1954); Rudrapur/Kichha 307.1 mm (25 Jul 1907); Pantnagar 403.9 mm (19 Oct 2021), excluded pending confirmation of its record length; Kotdwara 349.0 mm (1892) and Kathgodam 306.6 mm (1897), excluded as records made before 1901 [TBC] (IMD). Rates of 50–100 mm/h for about an hour at seven stations on 18 Oct 2021 (Thapliyal & Singh, 2023). The bhabar, 4–20 km wide, of boulders and gravel with water 40–75 m deep (173.71 m at Bhotia Parao, Haldwani), is the recharge zone; the terai below it, 8–25 km wide, has water 1–7 m deep and more than 2,000 flowing wells, an auto-flow zone that is retreating; Haldwani and Kashipur semi-critical (CGWB). Receiving waters: the Gaula (Kathgodam, 498.93 m on 20 Oct 2021; barrage pond 510.75–513.25 m), the Kosi (Ramnagar barrage, 220.75 or 220.95 m in 2021), the Dhela and Phika barrages, the Baur, Haripura and Tumaria reservoirs (full reservoir level 242.32 m), the Kalyani and the Kichha at Rudrapur, and the Sarda at Banbasa (highest level 224.9 m, 2021; barrage maximum water level 223.3 m) (as reported) |
| UK-Z2 Doon and outer ridge | The Doon valley and the first ranges of the outer Himalaya, where the monsoon is forced up and the daily totals are highest, in CWC zone 7, Western Himalayas (Clause 2.3.6(b)); catchments that cross a zone line take the higher zone value | Dehra Dun 42111 (daily record 1901–2012), Mussoorie 42112 (1901–1992), Nainital 42146 (1953–1980), Mukteswar 42147 (1901–2012); the recording gauges at Dehradun and Nainital used by the CWC zone-7 report; the automatic weather stations of Sahastradhara ITI, Maldevta and Jolly Grant | Gauge normals 2,000–2,500 mm (Nainital 2,464.5, Rajpur 2,426.1, Dehradun 2,238.3, Narendranagar 2,209.5, Mussoorie 2,021.6 mm) (IMD). FER zone 7 50-yr 24-h about 240–320 mm in the Doon and on its ridge, rising to more than 440 mm in the closed cell over Nainital. The Doon's records far exceed the plates: Raipur (Dehradun) 487.5 mm (1959), Dehradun (Obsy) 487.0 mm (1966), Rajpur 440.4 mm (1954) (IMD). The ADB Gumbel fits give 50-yr 24-h depths of 291 mm at Dehradun (1901–2020) and 417 mm at Nainital (1953–1970 only) (ADB, 2021). NIH-DHAARA close to the plates here (Dehradun 339, Nainital 426 mm) but low at 1 h |
| UK-Z2 Doon and outer ridge: UK-A Doon valley (Dehradun–Rishikesh) | Dehradun, Rajpur, Raipur–Maldevta–Sahastradhara, Doiwala, Rishikesh, Muni-ki-Reti, Dhalwala, Vikasnagar–Herbertpur, Selaqui, Sahaspur and Prem Nagar; Vikasnagar, Herbertpur, Selaqui and Prem Nagar lie in UTM zone 43N and Dehradun city just east of 78° E; boundaries [TBC] | Dehra Dun 42111; Rajpur (25 years of data); Narendranagar (33 years) for Rishikesh; the Dehradun recording gauges; Sahastradhara ITI and Maldevta (automatic weather stations) | FER zone 7 50-yr 24-h about 280–320 mm at Dehradun and Rishikesh (100-yr 320–360 mm). Records: Dehradun (Obsy) 487.0 mm (25 Jul 1966) and Rajpur 440.4 mm (25 Aug 1954), qualifying, for the Doon within 25 km of them; Narendranagar 396.0 mm (27 Jul 1999), qualifying, for Rishikesh; Raipur (Dehradun) 487.5 mm (2 Aug 1959; 16 years of data) excluded pending confirmation [TBC]; Dehradun 370.2 mm (17 Jun 2013) and 175.1 mm (14 Aug 2023); Sahastradhara 264 mm in 24 hours with 54 mm in one hour (16 Sep 2025, as reported); recording-gauge maxima at Dehradun 98 mm in 1 hour and 143 mm in 3 hours (14 Jun 1970) and 189 mm in 6 hours and 331 mm in 24 hours (24–25 Jul 1973) (IMD; CWC). The Doon Gravels, with hydraulic conductivity of 13–583 m/day and water 2–71 m deep before the monsoon, are the recharge zone; the Siwaliks to the south (CGWB). Receiving waters: the raos, ungauged and boulder-laden (the Rispana and the Bindal to the Suswa and the Song; the Tons; the Asan to the Asan barrage, maximum pond 401.50 m); the Song at Satyanarayan (warning 337.2 m, danger 338.2 m, highest level 338.49 m, 2019); the Yamuna at the Dakpathar barrage (pond 456.40 m); the Ganga at Rishikesh (danger 340.5 m, highest level 341.72 m, 1995) and the Pashulok barrage |
| UK-Z2 Doon and outer ridge: UK-D Outer-ridge hill stations (Nainital–Mussoorie) | Nainital, Bhimtal, Bhowali, Mussoorie, Landour, Lansdowne, Ranikhet, Mukteshwar, Champawat–Lohaghat, Narendranagar and Chakrata; boundaries [TBC] | Nainital 42146 (1953–1980) and its recording gauges; Mussoorie 42112; Mukteswar 42147 | FER zone 7 50-yr 24-h more than 440 mm at Nainital (taken as 480 mm under Clause 2.3.6(c)), about 240–280 mm at Mussoorie and Mukteshwar; 1(e) ratios on the zone-7 plate (Clause 2.3.6(f)). Records: Nainital 313.7 mm (15 Sep 1957) and 401 mm (19 Oct 2021), below the plate; Mukteshwar 340 mm (19 Oct 2021), qualifying, for Mukteshwar, Almora and Bhimtal; Mussoorie 439.4 mm (1890), excluded as a record made before 1901 and not shown in IMD's station extremes, which give 317.0 mm (5 Aug 1964) [TBC]; Ranikhet 350.5 mm (16 Jun 1970), years of data not printed [TBC]; Nainital's 50.9 cm (22 Sep 1958) in the zone-7 annex, contradicted by IMD [TBC]; recording-gauge maxima at Nainital 79 mm in 1 hour and 237 mm in 24 hours (3–4 Jul 1972) (IMD; CWC). Colluvium, slide debris and phyllite, slate and limestone, with perched springs; building barred on slopes of more than 30° (26.5° in Nainital); the Balia Nala and Sher-ka-Danda slides. Receiving waters: Naini lake (0.46 km², catchment 3.49 km² with the Sukhatal 0.75 km²; five sluices at Tallital, maximum 12.5 ft on the PWD gauge, sealed on 15 October) to the Balia Nala and the Gaula; Bhimtal; the headwaters of the Kempty, the Aglar, the Rispana and the Song below Mussoorie |
| UK-Z3 Inner and high mountains | The inner valleys, middle mountains and high Himalaya behind the outer ridge, in CWC zone 7 (Clause 2.3.6(b)), whose snow-fed catchments the zone-7 report excludes (Clause 2.3.6(i)); catchments that cross a zone line take the higher zone value | Tehri New 42114 (daily record 1956–2012), Joshimath 42116 (1958–2008), Mukteswar 42147; the recording gauges at Tehri and Uttarkashi used by the CWC zone-7 report; Askote (Obsy) and the Pithoragarh district gauges | Rain shadow: gauge normals of about 500–1,000 mm in the valleys (Srinagar 494.7, Pithoragarh 907.1, Joshimath 925.5 mm) against 2,200–2,600 mm on exposed slopes (Dharchula 2,222.9, Askote 2,588.1 mm) (IMD). FER zone 7 50-yr 24-h about 200–280 mm where the plates can be read (Tehri, Uttarkashi), with a closed cell of more than 400 mm on the upper Yamuna and Tons; 1-h ratio 0.425. Short bursts dominate: Uttarkashi 100 mm in 1 hour (12 Jul 1979), Tehri 50 mm in 1 hour (21 Jul 1971) (CWC). Winter storms of western disturbances (Mukhim 192.0 mm, Feb 1979; Naitwar 210.0 mm, Feb 1986) and snow. NIH-DHAARA broken at 1 h here (Joshimath 0.09, Kedarnath 0.12 of 24 h) |
| UK-Z3 Inner and high mountains: UK-E Inner valleys and middle mountains (Tehri–Srinagar–Almora–Pithoragarh) | Tehri, New Tehri, Chamba, Srinagar, Pauri, Rudraprayag, Agastyamuni, Gauchar, Karnaprayag, Gopeshwar, Uttarkashi, Barkot, Purola, Almora, Bageshwar, Pithoragarh and Berinag; boundaries [TBC] | Tehri New 42114; Mukteswar 42147 for Almora; Askote (Obsy, 26 years of data) and Berinag (23 years) for Pithoragarh district | FER zone 7 50-yr 24-h about 200–240 mm at Tehri and 240–280 mm at Uttarkashi; not legible at Almora, Pithoragarh and Srinagar [TBC]. Records: Askote (Obsy) 450.0 mm (5 Sep 1982), qualifying, for Pithoragarh town and Dharchula; Berinag 475.0 mm (6 Sep 1965), qualifying, for Berinag and Chaukori; Almora 222.5 mm (29 Sep 1924), Pithoragarh 200.7 mm (24 Jun 1921), Srinagar 190.5 mm (1880), Tehri (Obsy) 194.8 mm (12 Dec 1957), Uttarkashi 150.0 mm (20 Aug 1988) and Bhatwari 300.0 mm (15 Jul 1985) (IMD). Hard rock with weathered and colluvial veneers; springs supply 70–87% of the water in some blocks, and Almora's working springs are reported to have fallen from 360 to 60. Receiving waters: the Alaknanda (Srinagar warning 535.0 m, danger 536.0 m, highest level 537.9 m, 17 Jun 2013; Rudraprayag highest level 634.85 m, 2013), the Bhagirathi (Uttarkashi highest level 1,124.13 m, 1978), the Tehri reservoir (full reservoir level 830 m, maximum water level 835 m) and Koteshwar, the Kosi at Almora and the Ramganga; valley-floor towns on river terraces below debris fans |
| UK-Z3 Inner and high mountains: UK-F High Himalaya and snow-fed (Joshimath–Kedarnath–Dharchula) | Joshimath (Jyotirmath), Badrinath, Kedarnath, Gangotri, Harsil–Dharali, Yamunotri, Dharchula, Munsiari and Ghangaria, and every catchment with permanent snow or a glacier; boundaries [TBC] | Joshimath 42116 and the Joshimath district gauge (34 years of data); the glacier observatory at Chorabari (WIHG) | Zone-7 relations not used for snow-fed catchments; site-specific hydrology and a debris-flow and GLOF screening (Clause 2.3.6(i)). Records: Joshimath 300.0 mm (21 Jun 1973) and 273.0 mm (21 Jul 1970), Dharchula 271.4 mm (14 Jun 1971), Munsiyari 233.2 mm; Chorabari glacier camp 210 mm in 12 hours and 325 mm in 24 hours (15–16 Jun 2013) (IMD; Dobhal et al., 2013). Moraine and glacial debris (the subsidence of Joshimath, 2022–23); water 0.52 m below ground at Joshimath in January 2025 (CGWB). Events not driven by rain at the gauges: the Chorabari lake outburst (17 Jun 2013), the Raini rock-ice avalanche (7 Feb 2021) and the Dharali debris flow (5 Aug 2025). Receiving waters: the Alaknanda at Joshimath (highest level 1,388.65 m, 7 Feb 2021), the Mandakini, the Dhauliganga and the Kali at Dharchula |
Annex 2B — Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule
Supports Clauses 2.6.1 to 2.6.4 of Chapter 2.
To be prepared. This annex will tabulate, for each zone of Annex 2A, the ratios of the t-hour to the 24-hour design depth from NIH-DHAARA, which are derived from hourly records, against the ratios implied by IMD Das et al. (2022) and by the one-third rule. It needs NIH-DHAARA depths for each duration at representative points in each zone (NIH), IMD recording-gauge data and the IDF values of Das et al. (2022) (IMD). Until it is published, sub-daily depths are read directly from NIH-DHAARA or an approved station IDF (Clause 2.6.1). Where only daily depths are available, the ratios used are those agreed with the Authority, which in Uttarakhand are those of Clause 2.3.6: the CWC Flood Estimation Report ratios for the site's sub-area in Table 2B.1 (zone 7 in UK-A, UK-E and the local catchments of UK-F; 1(e) in UK-B, UK-C and, on the zone-7 plate depth, UK-D), raised at 1 and 3 hours in UK-B and UK-C to the floors of Clause 2.3.6(g) for the 10-yr and rarer storms, and applied to the 24-hour depth before the record check of Clause 2.3.6(h) (Clause 2.6.2), and are recorded on Form 2-1. The one-third rule is not used (Clause 2.6.4).
2B.1 The first row of Table 2B.1 gives the ratios of the one-third rule P(t) = P(24)·(t/24)^(1/3), for comparison only. The 1, 3, 6 and 12 h values are those stated in the commentary to Clause 2.6; the 2 h value is computed from the same formula. The rule shall not be used for design unless this annex confirms it for the zone concerned (Clause 2.6.4).
Table 2B.1 — Ratios P(t)/P(24h) by zone (layout)
| Zone | Source | 1 h | 2 h | 3 h | 6 h | 12 h | 24 h |
|---|---|---|---|---|---|---|---|
| All (reference only, not for design) | One-third rule | 0.35 | 0.44 | 0.50 | 0.63 | 0.79 | 1.00 |
| UK-Z2 (UK-A Doon valley) and UK-Z3 (UK-E Inner valleys and middle mountains; the local catchments of UK-F below the snow) | CWC FER zone 7, 10-yr basis, nine recording gauges (interim design ratios, Clause 2.3.6(f); 2-h value interpolated on logarithmic axes) | 0.425 | 0.600 | 0.725 | 0.845 | 1.00 | |
| UK-Z1 (UK-B Haridwar–Roorkee plains; UK-C Bhabar–terai) and UK-Z2 (UK-D Outer-ridge hill stations, on the zone-7 plate) | CWC FER 1(e), 50-yr (interim design ratios, Clause 2.3.6(f)) | 0.34 | 0.475 | 0.56 | 0.68 | 0.84 | 1.00 |
| UK-Z1 (UK-B, UK-C), 10-yr and rarer | Ratio floor of Clause 2.3.6(g)(i), set by this Manual (with the depth floors of Clause 2.3.6(g)(ii)) | 0.35 | 0.57 | ||||
| UK-Z2 (UK-A): Dehradun | CWC FER zone 7, Annex 4.4: the recording-gauge maxima as ratios to the 24-h maximum of the same record (separate storms: 1 and 3 h on 14 Jun 1970, 6 to 24 h on 24–25 Jul 1973; comparison only) | 0.30 | 0.43 | 0.57 | 0.65 | 1.00 | |
| UK-Z2 (UK-D): Nainital | CWC FER zone 7, Annex 4.4: recording-gauge maxima of 3–4 Jul 1972 (comparison only) | 0.33 | 0.53 | 0.77 | 1.00 | ||
| UK-Z3 (UK-E): Uttarkashi | CWC FER zone 7, Annex 4.4: recording-gauge maxima of 12–13 Jul 1979, a record of less than five years (comparison only) | 0.81 | 0.84 | 0.86 | 1.00 | ||
| UK-Z3 (UK-E): Tehri | CWC FER zone 7, Annex 4.4: recording-gauge maxima of 21–22 Jul 1971 (comparison only) | 0.55 | 0.99 | 1.00 | |||
| UK-Z1 (UK-B): Haridwar | NIH-DHAARA, 50-yr, Haridwar cell (comparison only; 2- to 12-hour values not queried) | 0.21 | 1.00 | ||||
| UK-Z1 (UK-B): Roorkee | NIH-DHAARA, 50-yr, Roorkee cell (comparison only; 3- and 6-hour values not queried) | 0.28 | 0.44 | 0.83 | 1.00 | ||
| UK-Z1 (UK-C): Haldwani | NIH-DHAARA, 50-yr, Haldwani cell (comparison only; 2- to 12-hour values not queried) | 0.24 | 1.00 | ||||
| UK-Z1 (UK-C): Rudrapur | NIH-DHAARA, 50-yr, Rudrapur cell (comparison only; 3- and 6-hour values not queried) | 0.25 | 0.40 | 0.82 | 1.00 | ||
| UK-Z1 (UK-C): Kashipur | NIH-DHAARA, 50-yr, Kashipur cell (comparison only; 2- to 12-hour values not queried) | 0.27 | 1.00 | ||||
| UK-Z2 (UK-A): Dehradun | NIH-DHAARA, 50-yr, Dehradun cell (comparison only; not used in the hills, Clause 2.3.6(m)) | 0.23 | 1.00 | ||||
| UK-Z2 (UK-A): Rishikesh | NIH-DHAARA, 50-yr, Rishikesh cell (comparison only; not used in the hills) | 0.20 | 0.33 | 0.79 | 1.00 | ||
| UK-Z2 (UK-D): Nainital | NIH-DHAARA, 50-yr, Nainital cell (comparison only; not used in the hills) | 0.18 | 1.00 | ||||
| UK-Z3 (UK-E): Srinagar | NIH-DHAARA, 50-yr, Srinagar cell (comparison only; not used in the hills) | 0.23 | 0.36 | 0.79 | 1.00 | ||
| UK-Z3 (UK-F): Joshimath | NIH-DHAARA, 50-yr, Joshimath cell (comparison only; not used in the hills) | 0.09 | 1.00 | ||||
| UK-Z3 (UK-F): Kedarnath | NIH-DHAARA, 50-yr, Kedarnath cell (comparison only; not used in the hills) | 0.12 | 1.00 |
2B.2 Depths from fixed observation windows are converted to true-interval depths with the factors of Clause 2.6.3, repeated in Table 2B.2. They are the standard WMO (Hershfield) values and are not provisional.
Table 2B.2 — Fixed-interval adjustment factors (Clause 2.6.3)
| Number of fixed observation intervals in the duration | Factor |
|---|---|
| 1 | 1.13 |
| 2 | 1.04 |
| 3–4 | 1.02 |
Annex 2C — Grid-to-point factors
Supports Clauses 2.7.1 and 2.7.4 of Chapter 2.
To be prepared. This annex will give the factors that convert grid-average design depths (for example from 0.25° cells) to point depths, by zone, duration and AEP. It needs paired frequency analyses of IMD gridded rainfall and of the IMD and State gauges inside each cell (IMD, the Irrigation Department, and the district rain gauges of the State whose records IMD tabulates [TBC]), the benchmark points of Annex 2A, and a stated method for deriving the factors. Until it is published, design depths are taken as point values from NIH-DHAARA or an approved station IDF (Clauses 2.3.1 and 2.3.2). Grid-average values are not used as design depths unless a conversion agreed with the Authority is recorded on Form 2-1 (Clause 1.11.5).
2C.1 The commentary to Clause 2.7 shows why the factors matter, and in Uttarakhand the reanalysis cells err in a pattern of their own. In the plains they run high: at Kashipur and Rudrapur the IMDAA cells of NIH-DHAARA (about 12 km) give a 50-year 24-hour depth of about 400 mm, against a plate value of 280–320 mm and gauge records of 315.0 mm at Kashipur (2 October 1954) and 307.1 mm at Rudrapur/Kichha (25 July 1907), and at Haridwar about 358 mm against about 280 mm. On the outer ridge they are close to the plates at 24 hours (Nainital 426 mm, Dehradun 339 mm), but at Dehradun the cell's 100-year depth, about 379 mm, is well below the observatory's 487.0 mm of 25 July 1966. In the high valleys they break down at short durations: the cells' 50-year 1-hour depths are about 24 mm at Joshimath and 32 mm at Kedarnath, 0.09 and 0.12 of their 24-hour depths, against the 100 mm in one hour recorded at Uttarkashi on 12 July 1979 and the 210 mm in 12 hours at the Chorabari glacier camp on 15–16 June 2013 (NIH-DHAARA, queried 10 Nov 2026; IMD; CWC; Dobhal et al., 2013); and the Tanakpur cell returned no data. Values of this kind are grid-average values and need these factors before any use as point depths; under Clause 2.3.6 they are not used as design depths in Uttarakhand until this annex and Annex 2A are published, and not used at all in the hills.
Table 2C.1 — Grid-to-point factors (layout)
| Zone | Grid product and cell size | Duration (h) | AEP | Factor (point / grid) | Stations used | Years of record |
|---|---|---|---|---|---|---|
| 24 | ||||||
| 48 | ||||||
| 72 |
Annex 2D — Uttarakhand temporal patterns (Huff curves)
Supports Clauses 2.9.3 and 2.9.4 of Chapter 2, and Clause 11.7.3 of Chapter 11.
To be prepared. This annex will give dimensionless time-distribution (mass) curves of Uttarakhand storms, in the form introduced by Huff (1967), by zone, storm-duration class and quartile, at stated probability levels. It needs storm hyetographs from recording gauges and automatic weather stations (IMD, its automatic weather stations and automatic rain gauges in the State, under the Meteorological Centre Dehradun, the glacier observatory of the Wadia Institute of Himalayan Geology at Chorabari, and any recording gauges of the Irrigation Department, USDMA and Dehradun Smart City Ltd [TBC]), separated into independent storms by a stated rule, and the storms recorded by the recording gauges of the CWC zone-7 report at Dehradun (14 June 1970 and 24–25 July 1973), Nainital (3–4 July 1972) and Uttarkashi (12–13 July 1979), the storm of 15–17 June 2013 at Dehradun and over the Mandakini, the Kumaon storm of 17–19 October 2021, the Dehradun storm of 13–14 August 2023 and the Sahastradhara storm of 15–16 September 2025 among them. Until it is published, design storms use the alternating-block pattern of Clause 2.9.1 and the 48- and 72-hour pattern of Clause 2.9.2; for catchments of 25–5,000 km², the CWC Flood Estimation Report curves may be used with a sensitivity run under Clause 2.9.1 (Clause 2.9.4). SCS Type distributions are not used (Clause 2.9.3). For the disaggregation of daily records in continuous simulation (Clause 11.7.3), the method is agreed with the Authority and recorded (Clause 1.11.5).
Table 2D.1 — Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)
| Fraction of storm time | 0 | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 10% probability curve | 0 | 1.0 | |||||||||
| 50% probability curve | 0 | 1.0 | |||||||||
| 90% probability curve | 0 | 1.0 |
2D.1 Each table shall state the zone, the duration class, the quartile (the quarter of the storm in which most rain fell), the number of storms analysed and the period of record.
Reference: Huff, F.A. (1967). Time distribution of rainfall in heavy storms. Water Resources Research 3(4), 1007–1019.
Annex 2E — Retention percentile depths by zone
Supports Clauses 2.8.3 and 2.10.1 to 2.10.2 of Chapter 2, Clause 4.4 of Chapter 4 and Chapter 8.
To be prepared. This annex will give, for each zone of Annex 2A, the retention design depth P_R: the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record (Clause 2.10.1). It needs long daily records at stations in each zone (IMD, the Irrigation Department, and the district rain gauges of the State whose records IMD tabulates [TBC]) and IMD gridded data with the factors of Annex 2C where stations are sparse. Until it is published, P_R is computed by the definition of Clause 2.10.1 from the long-term daily record of a station agreed with the Authority, by the steps in 2E.1, and recorded on Form 2-1 (Clause 1.11.5).
2E.1 Computing P_R from a daily record.
- Take the daily (24-hour) rainfall series of the station for its full record.
- Keep only the days with rain of 2.5 mm or more (wet days).
- Rank the wet-day depths and take the depth not exceeded on 90% of them (the 90th percentile).
- Do not apply the climate factor (Clause 2.8.3) or the fixed-interval factor; P_R is a statistic of everyday rainfall, not an AEP design depth.
- Record the station, the period of record, the number of wet days and P_R on Form 2-1.
Table 2E.1 — Retention depth P_R by zone (layout)
| Zone | Stations or grid cells used | Period of record | Number of wet days (≥ 2.5 mm) | P_R, 90th percentile (mm) | Issued on |
|---|---|---|---|---|---|
| UK-Z1 Plains and foothills | |||||
| UK-Z2 Doon and outer ridge | |||||
| UK-Z3 Inner and high mountains |
Form 2-1 — Design Rainfall Sheet
Supports Clauses 2.3 to 2.13 of Chapter 2, and Clause 10.4.1(d) of Chapter 10.
Draft form — Uttarakhand Stormwater Design Manual, Draft v1.0. One sheet for each hydrologic submittal. The steps follow Figure 2.3 of Chapter 2.
Table 2F.1 — Form 2-1: site, source and storms
| No. | Item (clause) | Entry |
|---|---|---|
| A. Site (Clause 2.13, item 1) | ||
| A1 | Project and site | ______ |
| A2 | Site coordinates (latitude, longitude, decimal degrees) | ______ |
| A3 | Rainfall zone (Annex 2A, or as agreed with the Authority) | ______ |
| A4 | Contributing catchment area (km²) (Clause 2.7) | ______ |
| A5 | Design life: more than 25 years / temporary works, 5 years or less (Clause 2.8.2) | ______ |
| A6 | Outfall under tidal or river backwater influence: Yes / No (Clauses 2.5.3, 2.12) | ______ |
| B. Source (Clauses 2.3, 2.3.5; item 2) | ||
| B1 | NIH-DHAARA: version or access date | ______ |
| B2 | Coordinates queried | ______ |
| B3 | Screenshot or export of the values extracted attached: reference | ______ |
| B4 | Station IDF used (Clause 2.3.2): No / Yes — station, ID, distance from site (km) | ______ |
| B5 | Station IDF: years of recording-gauge data (30 or more); published or approved by | ______ |
| B6 | Station IDF: change of terrain or coastal exposure between gauge and site: None / describe | ______ |
| C. AEPs and durations (Clauses 2.4, 2.5) | ||
| C1 | Elements designed and their AEPs (Table 2.1) | ______ |
| C2 | Conveyance: Tc and design duration (not less than 10 min) (Clause 2.5.1) | ______ |
| C3 | Storage: durations checked from {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48 and 72 h included (Clause 2.5.2) | ______ |
| C4 | Critical duration found for each storage element | ______ |
| D. Conversions | ||
| D1 | Sub-daily depths: read directly / from Annex 2B ratios / from ratios agreed with the Authority (Clauses 2.6.1, 2.6.2) | ______ |
| D2 | Fixed-interval factor applied: none (true-interval source) / 1.13 / 1.04 / 1.02 (Clause 2.6.3) | ______ |
| D3 | Grid-to-point factor: not needed (point source) / Annex 2C / agreed value (Clause 2.7.1) | ______ |
| D4 | ARF: 1.0 (10 km² or less; single-site storage) / CWC curve / interpolated (Clauses 2.7.2–2.7.4) | ______ |
| D5 | Climate factor: 1.20 (≤ 6 h) and 1.10 (> 6–72 h) / 1.0 temporary works / projected depths under Clause 2.8.4 | ______ |
| E. Cross-checks (Clause 2.3.3; item 4) | ||
| E1 | IMD Das et al. (2022) values for 1–24 h: reported in Table 2F.2 | ______ |
| E2 | CWC subzone 1(e) or zone 7 24-hour point value, catchments of 25–5,000 km²: subzone used | ______ |
| E3 | CWC floor governs for any AEP: No / Yes — AEPs | ______ |
| F. Retention depth (Clause 2.10) | ||
| F1 | P_R (mm) and source: Annex 2E zone value / computed under Annex 2E, 2E.1 — station and period | ______ |
| F2 | No climate factor applied to P_R (Clause 2.8.3): confirmed | ______ |
| G. Design storms (Clauses 2.9, 2.11, 2.12; items 5 and 6) | ||
| G1 | Storms up to 24 h: alternating block, peak at 50%; time step (≤ Tc/3 and ≤ 15 min) | ______ |
| G2 | 48 and 72 h storms: built under Clause 2.9.2 (Table 2F.3) | ______ |
| G3 | Other pattern used: none / Annex 2D / CWC FER with sensitivity run (Clauses 2.9.3, 2.9.4) | ______ |
| G4 | Hyetographs attached as a table and a plot for each design storm: reference | ______ |
| G5 | AMC: III for every design storm of 1 July–30 September in sub-areas UK-A, UK-D, UK-E and UK-F and on terai land, whatever its duration, and at any time in catchments draining to a reservoir or barrage pond, Naini lake or Bhimtal, or a river at or above its CWC warning level; at any other site or time, III for a storm that follows or contains a 5-day total of more than 53 mm; II otherwise (Clause 2.11.4) | ______ |
| G6 | Pre-development condition: greenfield, open land in good condition for the mapped HSG (Clause 2.11.5) | ______ |
| G7 | Release criterion: standard, Q_post ≤ 0.9 × Q_pre (Clause 2.11.2) / flood-sensitive, mixed-frequency rule (Clause 2.11.3) | ______ |
| G8 | Tailwater joint cases run (Clause 2.12): case (a) MHWS + sea-level allowance; case (b) 10% AEP 48 h storm with 1% AEP still-water level + sea-level allowance; governing case | ______ |
| H. Prepared by | ||
| H1 | I confirm that the values above are those extracted and used in the submittal. Name, registration number, signature, date | ______ |
Design depth = source depth × fixed-interval factor × grid-to-point factor × ARF × climate factor. Where the design depth is lower than the CWC floor for the same AEP, the floor is adopted (Clause 2.3.3).
Table 2F.2 — Form 2-1: depth table (Clause 2.13, item 3)
| AEP (T-yr) | Duration | Source depth (mm) | Fixed-interval factor | Grid-to-point factor | ARF | Climate factor | Design depth (mm) | IMD Das et al. (2022) (mm) | CWC floor (mm) | Adopted depth (mm) |
|---|---|---|---|---|---|---|---|---|---|---|
Table 2F.3 — Form 2-1: 48- and 72-hour storm construction (Clause 2.9.2)
| AEP (T-yr) | Duration (h) | Total design depth (mm) | 24 h design depth, final 24 h (mm) | Remainder (mm) | Hours before the final 24 h | Uniform intensity before the final 24 h (mm/h) |
|---|---|---|---|---|---|---|
| 48 | 24 | |||||
| 72 | 48 |