Annexes to Chapter 2Design Rainfall and Design Storms
These annexes support Chapter 2. Annexes 2A to 2E will hold the statewide rainfall tables that Chapter 2 refers to: the benchmark checks and zone map, sub-daily ratios, grid-to-point factors, temporal patterns and retention depths. Each needs analysis of NIH-DHAARA and IMD records that has not yet been done for this Manual, so each is marked "To be prepared" and gives its intended layout and the rule to use until it is published (Clause 1.11.5). Form 2-1 is a draft form for the Design Rainfall Sheet that every hydrologic submittal must include (Clause 2.13). The Manual is a draft; it is not adopted by any government or agency.
Annex 2A — NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map
Supports Clauses 2.3.1 to 2.3.5 of Chapter 2.
To be prepared. This annex will compare, at benchmark points across the State, the NIH-DHAARA design depths with frequency analyses of long IMD daily station records and of IMD gridded daily data (converted to point values with Annex 2C), for 24 hours and longer and for the AEPs of Table 2.1. It will also contain the map of rainfall zones used by Annexes 2B, 2C and 2E and by the Tier B tables of Chapter 4. It needs NIH-DHAARA values at the benchmark coordinates (NIH), IMD daily and recording-gauge station records and IMD gridded rainfall (IMD), State rain-gauge records (the district and tehsil rain gauges whose readings IMD tabulates in the Climate of Chhattisgarh, the gauges of WRD at its dams and barrages, and the agrometeorological observatory of Indira Gandhi Krishi Vishwavidyalaya at Raipur [TBC]), and district and basin boundaries (Survey of India, WRD). Until it is published, design depths are taken from NIH-DHAARA under Clause 2.3.1, the cross-checks of Clause 2.3.3 are reported on Form 2-1, and the zone of a site is the one agreed with the Authority and recorded on Form 2-1.
Table 2A.1 — Benchmark comparison of design depths (layout)
| Benchmark point | IMD station ID | Latitude, longitude | Years of record | Duration (h) | AEP | NIH-DHAARA (mm) | IMD station analysis (mm) | IMD gridded, point value (mm) | NIH-DHAARA / IMD station | Remarks |
|---|---|---|---|---|---|---|---|---|---|---|
| 24 | ||||||||||
| 48 | ||||||||||
| 72 |
2A.1 The zone names below are the working names used in the Tier B table template of Chapter 4 (Clause 4.14.2). Their boundaries, and whether further zones are needed, are to be set by the analysis of this annex.
Table 2A.2 — Rainfall zones (layout)
| Zone (working name) | Extent (districts, basins) | Representative stations | Notes |
|---|---|---|---|
| CG-Z1 Mahanadi plain | The Chhattisgarh plain and its northern and southern fringes in CWC subzone 3(d), the Mahanadi and Brahmani basins (Clause 2.3.6(b)); the Wainganga side of Rajnandgaon and Khairagarh lies in 3(f) and the Narmada fringe of Kawardha in 3(c); catchments that cross a zone line take the higher zone value | Raipur (Obsy) 42875 (daily record 1901–2012), Raipur (Mana) (A) 11203 (1979–2012), Durg 42876 (1969–2012), Rajnandgaon 11204 (1981–2008), Champa 42783 (1945–2012), Raigarh 42884 (1950–2012), Kanker 42953 (1927–2008), Pendra Road 42779 (1903–2012) | District normals about 1,010–1,390 mm (Kabirdham 1,011.2, Durg 1,061.5, Bilaspur and Balod 1,110.5, Raipur 1,129.3, Dhamtari 1,187.6, Mahasamund 1,205.7, Raigarh 1,321.2, Korba 1,354.1 mm; IMD, 1961–2010). FER 3(d) 50-yr 24-h about 200–360 mm, from a closed cell of less than 200 mm over Mungeli and Kawardha to about 360 mm at Gariaband, with a closed cell of more than 440 mm on the Odisha border; 1-h ratio 0.39, the highest in the State. Records that qualify under Clause 2.3.6(h) and raise the 100-yr depth above the plates: Raipur (Obsy) 42875, 370.3 mm (4 Aug 1910); Korba (23 years), 358.0 mm (12 Aug 2004); Champa 42783, 347.2 mm (26 Jul 1947) (IMD). Higher district-gauge records whose length of record is not confirmed, among them Rajnandgaon 392.0 mm (21 Sep 1965) and Durg 337.0 mm (15 Jun 2004), are excluded pending confirmation: each is admitted to the check of Clause 2.3.6(h) once IMD confirms at least 20 years of daily record at its gauge [TBC]. NIH-DHAARA 50-yr 24-h close to the plates at Raipur, Rajnandgaon, Bilaspur and Raigarh, high at Durg–Bhilai, Korba, Nava Raipur and Mahasamund |
| CG-Z1 Mahanadi plain: CG-A Raipur–Durg–Bhilai–Rajnandgaon plain (Seonath–Kharun, limestone) | Raipur, Birgaon, Nava Raipur Atal Nagar, Abhanpur, Durg, Bhilai, Bhilai-Charoda, Risali, Kumhari, Rajnandgaon, Dongargarh, Bemetara, Balod, Dhamdha, Simga and Baloda Bazar; boundaries [TBC] | Raipur (Obsy), Raipur (Mana), Durg, Rajnandgaon; the NRDA chart for Nava Raipur Atal Nagar (cross-check only, Clause 2.3.6(g)) | FER 50-yr 24-h about 240–280 mm at Durg and Bhilai and 280–320 mm at Raipur, Nava Raipur and Rajnandgaon. Records: Raipur (Obsy) 370.3 mm (4 Aug 1910; the same storm gave Kurud 381.0 mm and Arang 318.0 mm), qualifying under Clause 2.3.6(h); Raipur (Mana) 273.0 mm (30 Jun 2007) and Durg (Obsy) 260.4 mm (13 Aug 2006), below the plates; Rajnandgaon 392.0 mm (21 Sep 1965), Dongargarh 359.4 mm (1 Aug 1959), Durg 337.0 mm (15 Jun 2004) and Bhilai 288.3 mm (19 Aug 1939), district gauges excluded pending confirmation: each is admitted to the check of Clause 2.3.6(h) once IMD confirms at least 20 years of daily record at its gauge [TBC] (IMD). The karstified, cavernous Chandi and Charmuria limestone of the Raipur–Durg–Rajnandgaon belt; kanhar and dorsa on the plain, matasi and bhata on the uplands; critical groundwater blocks Dharsiwa (Raipur), Gurur, Nawagarh, Bemetara and Berla (CGWB, 2024). Receiving waters: the Kharun (Pathardihi highest level 281.68 m, 2020; no warning or danger level), the Seonath (Mongra barrage full reservoir level 337.150 m), Raipur's talabs and the lakes of Nava Raipur |
| CG-Z1 Mahanadi plain: CG-B Bilaspur–Mungeli–Kawardha (Arpa–Maniari–Hamp) | Bilaspur, Takhatpur, Bilha, Masturi, Mungeli, Lormi, Kawardha and Pandariya; the Narmada fringe of Kawardha lies in subzone 3(c); boundaries [TBC] | Pendra Road (the nearest long record, about 90 km north); the Bilaspur district gauge, whose length of record is to be obtained from IMD [TBC] | The driest part of the plain (Kabirdham 1,011.2 mm) and the lowest band of the FER plates: 50-yr 24-h about 200–240 mm at Bilaspur, at the edge of a closed cell of less than 200 mm. Records: Bilaspur 277.0 mm (29 Jun 2005), Pendra Road 262.1 mm (18 Aug 1953) (IMD); a fall reported as 28 cm, and as 415.6 mm, in 24 hours at Bilaspur in July 2026 is unresolved (as reported) [TBC]. Limestone and shale, with alluvium up to about 30 m at Bilaspur; Takhatpur and Belha semi-critical (CGWB, 2024). Receiving waters: the Arpa (Bhaisajhar barrage, full reservoir level 302.000 m; Kharang, spillway 994 m³/s), the Maniari (Maniyari, highest level 236.23 m, 2022) and the Hamp; Kopra Jalashay (Ramsar) |
| CG-Z1 Mahanadi plain: CG-C Korba–Janjgir–Champa–Raigarh (Hasdeo–Mand–Kelo coalfields) | Korba, Katghora, Dipka, Gevra, Kusmunda, Champa, Janjgir, Akaltara, Sakti, Raigarh, Kharsiya, Gharghoda, Tamnar and Sarangarh; boundaries [TBC] | Champa, Raigarh; the Korba district gauge (23 years) | FER 50-yr 24-h about 240–280 mm at Korba and Champa and about 320 mm at Raigarh (inferred [TBC]). Records: Korba 358.0 mm (12 Aug 2004) and Champa 347.2 mm (26 Jul 1947), qualifying under Clause 2.3.6(h); Raigarh (IMD station 42884) 315.2 mm (25 Aug 1970), below the plate; Janjgir 385.4 mm (16 Jun 1994), Raigarh 360.9 mm (10 Jul 1958) and Kharsiya 340.2 mm (7 Sep 2003), district gauges excluded pending confirmation: each is admitted to the check of Clause 2.3.6(h) once IMD confirms at least 20 years of daily record at its gauge [TBC]; Akaltara 282.7 mm on 28 Aug 2020 (IMD); Kathgora's 433.6 mm of 24 Nov 1958 is excluded under Clause 2.3.6(h) [TBC]. The Gondwana coalfields, with flowing wells, mine inflows and drawdown cones of about 1.2 km around Gevra and Kusmunda (as reported); the ash dykes of the power plants, with breaches reported in 2024–2026. Receiving waters: the Hasdeo below Minimata Bango and Darri (highest levels Bangodam 303.5 m and Katghora 313.58 m, 2026), the Mand (Kurubhata 220.4 m, 2020), the Kelo below the Kelo dam (full reservoir level 233.000 m) and the Mahanadi (Kalma 202.43 m, Surajgarh 201.06 m, 2020), with the Hirakud backwater on the low outfalls of Raigarh and Sarangarh |
| CG-Z1 Mahanadi plain: CG-D South-east plain (Dhamtari–Mahasamund–Gariaband–Rajim) | Dhamtari, Kurud, Mahasamund, Saraipali, Basna, Pithora, Rajim, Gariaband and the east of Arang; boundaries [TBC] | Kanker (nearest long record); Raipur (Obsy); the district gauges of Dhamtari and Mahasamund [TBC] | The wettest band of the plain on the FER plates: 50-yr 24-h about 320 mm at Dhamtari, 320–360 mm at Mahasamund and Rajim and about 360 mm at Gariaband, with a closed cell of more than 440 mm on the Odisha border; NIH-DHAARA's highest plain cell, Mahasamund, 380 mm. Records: Saraipali 508.3 mm and Basna 453.0 mm (29 Aug 2003), Kurud 381.0 mm (4 Aug 1910) and Dhamtari 313.2 mm (IMD), all district gauges excluded pending confirmation: each is admitted to the check of Clause 2.3.6(h) once IMD confirms at least 20 years of daily record at its gauge [TBC]; no record in this sub-area yet qualifies. Alluvium up to about 70 m at Dhamtari; Dhamtari, Kurud, Basna and Pithora semi-critical. Receiving waters: the Mahanadi below Gangrel (Ravishankar Sagar, full reservoir level 348.700 m, 14 gates, spillway 17,230 m³/s), the Pairi (Malgaon highest level 329.33 m, 2026) and the Kodar |
| CG-Z2 Bastar plateau | The Bastar plateau and the Godavari frontage of the south, in CWC subzones 3(g) (the Indravati) and 3(f) (the Sabari and the Godavari) (Clause 2.3.6(b)); catchments that cross a zone line take the higher zone value | Jagdalpur 43041 (daily record 1910–2012), Kanker 42953 (1927–2008), Bailadila 43093 (1977–2002) | The wettest districts of the State (Bastar 1,575.7 mm, Dantewada 1,839.3 mm; IMD). FER 3(g) 50-yr 24-h about 240–280 mm at Jagdalpur, with a closed cell of less than 200 mm over the Indravati valley west of it; 1-h ratio 0.32 (3(g), 3(f)). NIH-DHAARA high here (Jagdalpur 340, Dantewada 342, Sukma 355 mm). Earliest onset (Jagdalpur 11–13 June) and latest withdrawal (12–14 October) in the State; pre-monsoon storms (Bailadila 207.0 mm, 11 May 1990) (IMD) |
| CG-Z2 Bastar plateau: CG-E Bastar plateau and Godavari frontage | Jagdalpur, Kondagaon, Keskal, Narayanpur, Dantewada, Kirandul and Bacheli (Bailadila), Bijapur, Bhopalpatnam, Sukma, Konta, Pakhanjur and the south of Kanker district; Jagdalpur on the line between 3(g) and 3(f) (Clause 2.3.6(b)); boundaries [TBC] | Jagdalpur, Bailadila; the FER recording gauges at Jagdalpur, Paralkote, Bhopalpatnam and Sukma (1969–1986) | Records: Jagdalpur 43041, 259.7 mm (17 Jun 1974), and Bailadila 43093, 292.4 mm (18 Jun 1999), below the plates; Bijapur 362.0 mm (26 Jul 1988), Dantewada 355.0 mm (31 Aug 1976), Konta 340.0 mm and Sukma 325.0 mm (3–4 Aug 2006), district gauges excluded pending confirmation: each is admitted to the check of Clause 2.3.6(h) once IMD confirms at least 20 years of daily record at its gauge [TBC] (IMD); recording-gauge maxima Jagdalpur 80.0 mm in 1 hour and Bhopalpatnam 145.5 mm in 3 hours (8 Aug 1974) (CWC FER 3(g)). Granite-gneiss of the Bastar craton, the Bailadila iron formation and laterite; crystalline aquifers of low yield. Receiving waters: the Indravati at Jagdalpur (CWC warning 539.49 m, danger 540.80 m, highest level 544.891 m on 26 Sep 2026), rising in Odisha; the Indravati at Chindnar, the Narangi at Sonarpal, the Sabari at Talnar and Konta (as reported) |
| CG-Z3 Northern hills | The northern hill ranges, in CWC subzones 1(d) (the Rihand, Kanhar and Gopad, to the Sone) and 3(d) (the headwaters of the Hasdeo and the Mand, the Ib and the Brahmani side of Jashpur) (Clause 2.3.6(b)); catchments that cross a zone line take the higher zone value | Ambikapur 42693 (daily record 1951–2012), Jashpurnagar 42790 (1965–2012), Pendra Road 42779 (1903–2012) | District normals about 1,190–1,490 mm (Balrampur 1,191.5, Koriya 1,212.0, Surajpur 1,301.0, Surguja 1,386.9, Jashpur 1,486.9 mm; IMD). FER 1(d) 50-yr 24-h a closed contour of more than 280 mm around Ambikapur; 3(d) about 200–280 mm at Manendragarh and Jashpur Nagar, unresolved [TBC]; 1-h ratio 0.37 (1(d)). NIH-DHAARA low here (Ambikapur 249, Manendragarh 217, Jashpur 208 mm). October storms (Ambikapur 206.0 mm, 1 Oct 1961; Pendra Road 228.1 mm, 8 Oct 1994) (IMD) |
| CG-Z3 Northern hills: CG-F Northern hills (Surguja–Koriya–Jashpur) | Ambikapur, Bishrampur, Surajpur, Balrampur, Ramanujganj, Wadrafnagar, Manendragarh, Chirmiri, Baikunthpur, Jashpur Nagar, Kunkuri, Pathalgaon and Mainpat; Jashpur Nagar and the east of Jashpur district lie in UTM zone 45N; boundaries [TBC] | Ambikapur, Jashpurnagar | Records: Jashpurnagar 42790, 365.0 mm (30 Jun 2001), qualifying under Clause 2.3.6(h); Ambikapur 42693, 206.0 mm (1 Oct 1961), the station's highest day; Samaria (Surajpur) 540.0 mm (13 Aug 2003), Ambikapur (district gauge) 341.6 mm (27 Jun 1945), Baikunthpur 326.4 mm (4 Jul 1915) and Ramanujganj 320.0 mm (11 Sep 1987), district gauges excluded pending confirmation: each is admitted to the check of Clause 2.3.6(h) once IMD confirms at least 20 years of daily record at its gauge [TBC] (IMD). Excluded under Clause 2.3.6(h) until IMD confirms them [TBC]: Wadrafnagar 917.2 mm (8 Sep 2003; a gauge of about 10 years), Ambikapur 456.7 mm (24 Jul 1991; contradicted by IMD's station extremes, 174.0 mm on 23 Jul 1991) and Bharatanagar 301.0 mm (9 Jan 1995). Gondwana coalfields (Bishrampur, Chirmiri, Baikunthpur and Hasdeo-Arand); laterite on the trap of Mainpat and Jashpur. Receiving waters: the Rihand and the Kanhar, the headwaters of the Hasdeo, and the Ib and the Sankh; no CWC site with published levels found [TBC] |
Annex 2B — Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule
Supports Clauses 2.6.1 to 2.6.4 of Chapter 2.
To be prepared. This annex will tabulate, for each zone of Annex 2A, the ratios of the t-hour to the 24-hour design depth from NIH-DHAARA, which are derived from hourly records, against the ratios implied by IMD Das et al. (2022) and by the one-third rule. It needs NIH-DHAARA depths for each duration at representative points in each zone (NIH), IMD recording-gauge data and the IDF values of Das et al. (2022) (IMD). Until it is published, sub-daily depths are read directly from NIH-DHAARA or an approved station IDF (Clause 2.6.1). Where only daily depths are available, the ratios used are those agreed with the Authority, which in Chhattisgarh are those of Clause 2.3.6: the CWC Flood Estimation Report ratios for the site's subzone in Table 2B.1, used as they stand at every AEP, with no absolute floor, applied to the 24-hour depth before the record check of Clause 2.3.6(h) (Clause 2.6.2), and are recorded on Form 2-1. The one-third rule is not used (Clause 2.6.4).
2B.1 The first row of Table 2B.1 gives the ratios of the one-third rule P(t) = P(24)·(t/24)^(1/3), for comparison only. The 1, 3, 6 and 12 h values are those stated in the commentary to Clause 2.6; the 2 h value is computed from the same formula. The rule shall not be used for design unless this annex confirms it for the zone concerned (Clause 2.6.4).
Table 2B.1 — Ratios P(t)/P(24h) by zone (layout)
| Zone | Source | 1 h | 2 h | 3 h | 6 h | 12 h | 24 h |
|---|---|---|---|---|---|---|---|
| All (reference only, not for design) | One-third rule | 0.35 | 0.44 | 0.50 | 0.63 | 0.79 | 1.00 |
| CG-Z1 (CG-A to CG-D) and CG-Z3 (CG-F, the Hasdeo, Mand, Ib and Brahmani side) | CWC FER 3(d), 10-yr basis (interim design ratios, Clause 2.3.6(f)) | 0.39 | 0.61 | 0.76 | 0.86 | 1.00 | |
| CG-Z2 (CG-E, the Indravati side, including Jagdalpur) | CWC FER 3(g), 10-yr basis (interim design ratios, Clause 2.3.6(f)) | 0.32 | 0.50 | 0.635 | 0.80 | 1.00 | |
| CG-Z2 (CG-E, the Sabari and Godavari side: Sukma, Konta; and Jagdalpur, which takes the higher of 3(g) and 3(f) at each duration) and CG-Z1 (the Wainganga side of CG-A) | CWC FER 3(f), 10-yr basis (interim design ratios, Clause 2.3.6(f)) | 0.32 | 0.52 | 0.65 | 0.79 | 1.00 | |
| CG-Z3 (CG-F, the Sone side, including Ambikapur) | CWC FER 1(d), 50-yr (interim design ratios, Clause 2.3.6(f)) | 0.37 | 0.58 | 0.70 | 0.89 | 1.00 | |
| CG-Z1 (CG-B, the Narmada fringe of Kawardha; used with the higher of the 3(d) ratios, Clause 2.3.6(b)) | CWC FER 3(c), 10-yr basis (interim design ratios, Clause 2.3.6(f)) | 0.34 | 0.50 | 0.63 | 0.79 | 1.00 | |
| CG-Z1 (CG-A edge): Kanker | CWC FER 3(d), Annex 4.4: the recording-gauge maxima of 1969–1980 as ratios to the 24-h maximum of the same record (separate storms, comparison only; 1-h value 75.3 mm in the 3(g) report) | 0.34 | 0.49 | 0.69 | 0.75 | 1.00 | |
| CG-Z1 (CG-A): Nava Raipur Atal Nagar | NRDA chart, Naya Raipur Development Plan-2031, Fig. 10.1 (no 1-h or 24-h point, so no ratio to 24 h can be formed; 50-yr depths read by eye about 120 mm at 3 h and 138 mm at 6 h; cross-check only, Clause 2.3.6(g)) | — | — | — | — | — | |
| CG-Z1 (CG-A): Raipur | NIH-DHAARA, 50-yr, Raipur cell (comparison only; 3- and 6-hour values not queried) | 0.20 | 0.34 | 0.80 | 1.00 | ||
| CG-Z1 (CG-A): Nava Raipur | NIH-DHAARA, 50-yr, Nava Raipur cell (comparison only; 3- and 6-hour values not queried) | 0.22 | 0.37 | 0.79 | 1.00 | ||
| CG-Z1 (CG-A): Durg | NIH-DHAARA, 50-yr, Durg cell (comparison only; 3- and 6-hour values not queried) | 0.20 | 0.35 | 0.83 | 1.00 | ||
| CG-Z1 (CG-B): Bilaspur | NIH-DHAARA, 50-yr, Bilaspur cell (comparison only; 3- and 6-hour values not queried) | 0.27 | 0.41 | 0.77 | 1.00 | ||
| CG-Z1 (CG-C): Korba | NIH-DHAARA, 50-yr, Korba cell (comparison only; 3- and 6-hour values not queried) | 0.25 | 0.42 | 0.83 | 1.00 | ||
| CG-Z1 (CG-C): Raigarh | NIH-DHAARA, 50-yr, Raigarh cell (comparison only; 3- and 6-hour values not queried) | 0.25 | 0.39 | 0.79 | 1.00 | ||
| CG-Z1 (CG-D): Mahasamund | NIH-DHAARA, 50-yr, Mahasamund cell (comparison only; 3- and 6-hour values not queried) | 0.20 | 0.34 | 0.82 | 1.00 | ||
| CG-Z2 (CG-E): Jagdalpur | NIH-DHAARA, 50-yr, Jagdalpur cell (comparison only; 3- and 6-hour values not queried) | 0.25 | 0.43 | 0.84 | 1.00 | ||
| CG-Z3 (CG-F): Ambikapur | NIH-DHAARA, 50-yr, Ambikapur cell (comparison only; 3- and 6-hour values not queried) | 0.25 | 0.39 | 0.78 | 1.00 |
2B.2 Depths from fixed observation windows are converted to true-interval depths with the factors of Clause 2.6.3, repeated in Table 2B.2. They are the standard WMO (Hershfield) values and are not provisional.
Table 2B.2 — Fixed-interval adjustment factors (Clause 2.6.3)
| Number of fixed observation intervals in the duration | Factor |
|---|---|
| 1 | 1.13 |
| 2 | 1.04 |
| 3–4 | 1.02 |
Annex 2C — Grid-to-point factors
Supports Clauses 2.7.1 and 2.7.4 of Chapter 2.
To be prepared. This annex will give the factors that convert grid-average design depths (for example from 0.25° cells) to point depths, by zone, duration and AEP. It needs paired frequency analyses of IMD gridded rainfall and of the IMD and State gauges inside each cell (IMD, WRD, and the district and tehsil rain gauges of the State whose records IMD tabulates [TBC]), the benchmark points of Annex 2A, and a stated method for deriving the factors. Until it is published, design depths are taken as point values from NIH-DHAARA or an approved station IDF (Clauses 2.3.1 and 2.3.2). Grid-average values are not used as design depths unless a conversion agreed with the Authority is recorded on Form 2-1 (Clause 1.11.5).
2C.1 The commentary to Clause 2.7 shows why the factors matter, and in Chhattisgarh the reanalysis cells err both ways. At Jashpur the IMDAA cell of NIH-DHAARA (about 12 km) gives a 50-year 24-hour depth of about 208 mm and a 100-year depth of about 233 mm, while the Jashpurnagar gauge recorded 365.0 mm on 30 June 2001; at Ambikapur the cell's 50-year value, about 249 mm, is below the closed contour of more than 280 mm of the CWC plate and below the 341.6 mm recorded at Ambikapur on 27 June 1945; and at Kanker the cell's value, about 247 mm, is below the plate value of 280–320 mm. At Durg the cell's value, about 333 mm, is above the plate value of 240–280 mm, and at Jagdalpur its value of about 340 mm is above both the plate value of 240–280 mm and the station's record of 259.7 mm (17 June 1974). The cells' 50-year 1-hour depths, about 54–85 mm, are 0.20–0.29 of their 24-hour depths, and at Raipur 62.7 mm against about 109–125 mm from the 3(d) plates and ratios (NIH-DHAARA, queried 7 Nov 2026; IMD; CWC). Values of this kind are grid-average values and need these factors before any use as point depths; under Clause 2.3.6 they are not used as design depths in Chhattisgarh until this annex and Annex 2A are published.
Table 2C.1 — Grid-to-point factors (layout)
| Zone | Grid product and cell size | Duration (h) | AEP | Factor (point / grid) | Stations used | Years of record |
|---|---|---|---|---|---|---|
| 24 | ||||||
| 48 | ||||||
| 72 |
Annex 2D — Chhattisgarh temporal patterns (Huff curves)
Supports Clauses 2.9.3 and 2.9.4 of Chapter 2, and Clause 11.7.3 of Chapter 11.
To be prepared. This annex will give dimensionless time-distribution (mass) curves of Chhattisgarh storms, in the form introduced by Huff (1967), by zone, storm-duration class and quartile, at stated probability levels. It needs storm hyetographs from recording gauges and automatic weather stations (IMD, its automatic weather stations and automatic rain gauges in the State, under the Meteorological Centre Raipur, and any recording gauges of WRD and of the Municipal Corporations, NRDA and the Smart City companies [TBC]), separated into independent storms by a stated rule, and the storms recorded by the recording gauges of the CWC reports at Kanker (26 June 1974 and 18 September 1980), Jagdalpur and Bhopalpatnam (8 August 1974), the Durg storm of 15 June 2004, the Korba storm of 12 August 2004, the Bilaspur storm of 29–30 June 2005, the Raipur storm of 30 June 2007, the upper Mahanadi storm of 28–29 August 2020, the Bastar storm of 26–27 August 2025 and the statewide storm of 24–27 September 2026 among them. Until it is published, design storms use the alternating-block pattern of Clause 2.9.1 and the 48- and 72-hour pattern of Clause 2.9.2; for catchments of 25–5,000 km², the CWC Flood Estimation Report curves may be used with a sensitivity run under Clause 2.9.1 (Clause 2.9.4). SCS Type distributions are not used (Clause 2.9.3). For the disaggregation of daily records in continuous simulation (Clause 11.7.3), the method is agreed with the Authority and recorded (Clause 1.11.5).
Table 2D.1 — Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)
| Fraction of storm time | 0 | 0.1 | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1.0 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 10% probability curve | 0 | 1.0 | |||||||||
| 50% probability curve | 0 | 1.0 | |||||||||
| 90% probability curve | 0 | 1.0 |
2D.1 Each table shall state the zone, the duration class, the quartile (the quarter of the storm in which most rain fell), the number of storms analysed and the period of record.
Reference: Huff, F.A. (1967). Time distribution of rainfall in heavy storms. Water Resources Research 3(4), 1007–1019.
Annex 2E — Retention percentile depths by zone
Supports Clauses 2.8.3 and 2.10.1 to 2.10.2 of Chapter 2, Clause 4.4 of Chapter 4 and Chapter 8.
To be prepared. This annex will give, for each zone of Annex 2A, the retention design depth P_R: the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record (Clause 2.10.1). It needs long daily records at stations in each zone (IMD, WRD, and the district and tehsil rain gauges of the State whose records IMD tabulates [TBC]) and IMD gridded data with the factors of Annex 2C where stations are sparse. Until it is published, P_R is computed by the definition of Clause 2.10.1 from the long-term daily record of a station agreed with the Authority, by the steps in 2E.1, and recorded on Form 2-1 (Clause 1.11.5).
2E.1 Computing P_R from a daily record.
- Take the daily (24-hour) rainfall series of the station for its full record.
- Keep only the days with rain of 2.5 mm or more (wet days).
- Rank the wet-day depths and take the depth not exceeded on 90% of them (the 90th percentile).
- Do not apply the climate factor (Clause 2.8.3) or the fixed-interval factor; P_R is a statistic of everyday rainfall, not an AEP design depth.
- Record the station, the period of record, the number of wet days and P_R on Form 2-1.
Table 2E.1 — Retention depth P_R by zone (layout)
| Zone | Stations or grid cells used | Period of record | Number of wet days (≥ 2.5 mm) | P_R, 90th percentile (mm) | Issued on |
|---|---|---|---|---|---|
| CG-Z1 Mahanadi plain | |||||
| CG-Z2 Bastar plateau | |||||
| CG-Z3 Northern hills |
Form 2-1 — Design Rainfall Sheet
Supports Clauses 2.3 to 2.13 of Chapter 2, and Clause 10.4.1(d) of Chapter 10.
Draft form — Chhattisgarh Stormwater Design Manual, Draft v1.0. One sheet for each hydrologic submittal. The steps follow Figure 2.3 of Chapter 2.
Table 2F.1 — Form 2-1: site, source and storms
| No. | Item (clause) | Entry |
|---|---|---|
| A. Site (Clause 2.13, item 1) | ||
| A1 | Project and site | ______ |
| A2 | Site coordinates (latitude, longitude, decimal degrees) | ______ |
| A3 | Rainfall zone (Annex 2A, or as agreed with the Authority) | ______ |
| A4 | Contributing catchment area (km²) (Clause 2.7) | ______ |
| A5 | Design life: more than 25 years / temporary works, 5 years or less (Clause 2.8.2) | ______ |
| A6 | Outfall under tidal or river backwater influence: Yes / No (Clauses 2.5.3, 2.12) | ______ |
| B. Source (Clauses 2.3, 2.3.5; item 2) | ||
| B1 | NIH-DHAARA: version or access date | ______ |
| B2 | Coordinates queried | ______ |
| B3 | Screenshot or export of the values extracted attached: reference | ______ |
| B4 | Station IDF used (Clause 2.3.2): No / Yes — station, ID, distance from site (km) | ______ |
| B5 | Station IDF: years of recording-gauge data (30 or more); published or approved by | ______ |
| B6 | Station IDF: change of terrain or coastal exposure between gauge and site: None / describe | ______ |
| C. AEPs and durations (Clauses 2.4, 2.5) | ||
| C1 | Elements designed and their AEPs (Table 2.1) | ______ |
| C2 | Conveyance: Tc and design duration (not less than 10 min) (Clause 2.5.1) | ______ |
| C3 | Storage: durations checked from {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48 and 72 h included (Clause 2.5.2) | ______ |
| C4 | Critical duration found for each storage element | ______ |
| D. Conversions | ||
| D1 | Sub-daily depths: read directly / from Annex 2B ratios / from ratios agreed with the Authority (Clauses 2.6.1, 2.6.2) | ______ |
| D2 | Fixed-interval factor applied: none (true-interval source) / 1.13 / 1.04 / 1.02 (Clause 2.6.3) | ______ |
| D3 | Grid-to-point factor: not needed (point source) / Annex 2C / agreed value (Clause 2.7.1) | ______ |
| D4 | ARF: 1.0 (10 km² or less; single-site storage) / CWC curve / interpolated (Clauses 2.7.2–2.7.4) | ______ |
| D5 | Climate factor: 1.20 (≤ 6 h) and 1.10 (> 6–72 h) / 1.0 temporary works / projected depths under Clause 2.8.4 | ______ |
| E. Cross-checks (Clause 2.3.3; item 4) | ||
| E1 | IMD Das et al. (2022) values for 1–24 h: reported in Table 2F.2 | ______ |
| E2 | CWC subzone 3(d) / 3(g) / 3(f) / 1(d) / 3(c) 24-hour point value, catchments of 25–5,000 km²: subzone used | ______ |
| E3 | CWC floor governs for any AEP: No / Yes — AEPs | ______ |
| F. Retention depth (Clause 2.10) | ||
| F1 | P_R (mm) and source: Annex 2E zone value / computed under Annex 2E, 2E.1 — station and period | ______ |
| F2 | No climate factor applied to P_R (Clause 2.8.3): confirmed | ______ |
| G. Design storms (Clauses 2.9, 2.11, 2.12; items 5 and 6) | ||
| G1 | Storms up to 24 h: alternating block, peak at 50%; time step (≤ Tc/3 and ≤ 15 min) | ______ |
| G2 | 48 and 72 h storms: built under Clause 2.9.2 (Table 2F.3) | ______ |
| G3 | Other pattern used: none / Annex 2D / CWC FER with sensitivity run (Clauses 2.9.3, 2.9.4) | ______ |
| G4 | Hyetographs attached as a table and a plot for each design storm: reference | ______ |
| G5 | AMC: III for every design storm of 1 July–30 September on kanhar or dorsa paddy lowland, talab-draining and valley-floor sites, whatever its duration, and at any time in catchments draining to a reservoir or barrage pond, the Hirakud backwater, a mine void or a river at or above its CWC warning level; at any other site or time, III for a storm that follows or contains a 5-day total of more than 53 mm; II otherwise (Clause 2.11.4) | ______ |
| G6 | Pre-development condition: greenfield, open land in good condition for the mapped HSG (Clause 2.11.5) | ______ |
| G7 | Release criterion: standard, Q_post ≤ 0.9 × Q_pre (Clause 2.11.2) / flood-sensitive, mixed-frequency rule (Clause 2.11.3) | ______ |
| G8 | Tailwater joint cases run (Clause 2.12): case (a) MHWS + sea-level allowance; case (b) 10% AEP 48 h storm with 1% AEP still-water level + sea-level allowance; governing case | ______ |
| H. Prepared by | ||
| H1 | I confirm that the values above are those extracted and used in the submittal. Name, registration number, signature, date | ______ |
Design depth = source depth × fixed-interval factor × grid-to-point factor × ARF × climate factor. Where the design depth is lower than the CWC floor for the same AEP, the floor is adopted (Clause 2.3.3).
Table 2F.2 — Form 2-1: depth table (Clause 2.13, item 3)
| AEP (T-yr) | Duration | Source depth (mm) | Fixed-interval factor | Grid-to-point factor | ARF | Climate factor | Design depth (mm) | IMD Das et al. (2022) (mm) | CWC floor (mm) | Adopted depth (mm) |
|---|---|---|---|---|---|---|---|---|---|---|
Table 2F.3 — Form 2-1: 48- and 72-hour storm construction (Clause 2.9.2)
| AEP (T-yr) | Duration (h) | Total design depth (mm) | 24 h design depth, final 24 h (mm) | Remainder (mm) | Hours before the final 24 h | Uniform intensity before the final 24 h (mm/h) |
|---|---|---|---|---|---|---|
| 48 | 24 | |||||
| 72 | 48 |