Draft v1.0 prepared by NEER. Not adopted by the Government of Meghalaya, any District Council, authority or local body, and has no legal force. About this draft

Chapter 2Design Rainfall and Design Storms


2.1 Purpose and scope

2.1.1 This chapter sets the rainfall inputs for every hydrologic calculation in this Manual: drain and inlet sizing (Chapter 6), retention and detention sizing (Chapter 4), downstream and tailwater analysis (Chapter 5), and waterbody and tank works (Chapter 7).

2.1.2 It specifies:

  • (a) the approved sources of design rainfall depth and intensity;
  • (b) how depths are converted between durations, between point and area, and from present to future climate;
  • (c) how design storms (hyetographs) are constructed; and
  • (d) the storms that must be applied to pre- and post-development conditions.

2.1.3 This chapter applies throughout Meghalaya. Where a Municipal Board, MUDA, the Shillong Cantonment Board, NSTDA or a District Council has adopted a stricter rainfall standard under Chapter 1, the stricter standard governs.

Commentary. Most past drainage failures in Meghalaya trace to the rainfall input, not the hydraulics. Meghalaya shows how. No design storm was found for any town's drains in the State: Shillong's 148.91 km of drains state none (Smart City Proposal 2016-17, as quoted in the IRADe/NMHS plan), and the one method found, RMSI's for Shillong in 2019, took its design rainfall from a CWC atlas of probable maximum precipitation that was not obtained for this Manual (as quoted in the same plan). The published sources that seem to fill the gap do not. The CWC report for subzone 2(b) gives Shillong about 560 mm in 24 hours at 50 years, about twice IMD's record for the station, and its 1-hour ratio of 0.48 would give the city about 269 mm in an hour, 5.6 times the largest hour its recording gauge has measured; the escarpment, the wettest belt on record, lies in subzone 2(c), for which CWC has published no report at all. The Shillong panel of IMD Das et al. (2022) is a generic curve, not station data, and NIH-DHAARA gives Dawki 1,423 mm in a day at 50 years, more than Mawsynram (Clause 2.3.6). The rainfall figures that circulate after a flood often conflict: Cherrapunji's day of 16 June 1995 is 1,563.0 mm in IMD's tables and 1,563.3 mm in the press, Sohra's day to 15 June 2022 is reported as 811.6 mm and 811.2 mm, Mawsynram's previous June record as 945.4 mm by IMD and 944.7 mm in the press, and Shillong's highest day as 273.2 mm by IMD and 347 mm by the 2(b) report's recording gauge (IMD; CWC; as reported). Fixing one transparent source and method for the whole state is the main purpose of this chapter.


2.2 Definitions

Term Meaning in this Manual
Annual exceedance probability (AEP) Probability that a given rainfall depth is equalled or exceeded in any one year. A 1% AEP storm is the "100-year" storm. Both forms are used here: T-year = 1/AEP.
IDF / DDF Intensity–duration–frequency and depth–duration–frequency relationships for a location.
Point rainfall Rainfall at a single location, as measured by a rain gauge.
Design storm A hyetograph (rainfall depth versus time) of stated AEP, duration and temporal pattern.
Critical duration The storm duration that produces the largest peak flow, water level or storage requirement for the element being designed.
Areal reduction factor (ARF) Ratio of catchment-average rainfall to point rainfall for the same AEP and duration.
Monsoon season (as used in this Manual) 1 April to 31 October. In this Manual "the monsoon" and "the monsoon season" mean this wet season, which takes in IMD's pre-monsoon months of April and May as well as the south-west monsoon; it is the Manual's season, not IMD's. IMD's south-west monsoon reaches Shillong about the first week of June (its old normal date for Shillong was 1 June, as reported; the revised normals in use since 2020 were not read for this Manual [TBC]; in 2026 it reached "substantial parts" of the North East on 7 June, "two days later than its normal", as reported) and withdraws from the State about the middle of October (expected by 14 October in 2025, and from the North East on 15 October in 2026, "close to its normal date", as reported). The season begins on 1 April because the storms of April and May are among the State's largest: Cherrapunji's highest days are 644.2 mm in April (16 April 1990) and 812.0 mm in May (25 May 1916), each larger than the 50-year 24-hour value that the 2(b) plates give anywhere in the Brahmaputra valley (NEER reading), and its May total has reached 3,961.2 mm (1984) (IMD, Extremes); the CWC 2(b) report finds the rain "spread over a period of eight months, i.e. from March to October", with thunderstorms in April and May and "May rainfall … more than the September rainfall" (CWC, 2(b), p. 20); the highest levels at two of the State's CWC sites fell before June, on the Myntdu at Kharkhana (47.0 m, 23 April 1995) and the Umngot at Dawki (73.47 m, 28 May 2006) (CWC data as transcribed by SANDRP); and the floods and landslides of 30–31 May 2025 came before the south-west monsoon (as reported). A works deadline of 31 May would leave those storms uncovered, so the pre-monsoon deadline of 31 March is set before the season begins (Chapter 10). CGWB's reports say both that the monsoon "usually starts from the middle of May" and that the rainy season "commences with the onset of southwest monsoon in April" (CGWB, GWRA 2022); those are CGWB's statements, not IMD's dates, and they disagree. The wettest months on record are July 1974 at both IMD stations, 6,667.4 mm at Cherrapunji and 1,086.8 mm at Shillong (IMD, Extremes). Annual normals run from 225.3 cm at Shillong (Obsy) and 242.5 cm at Upper Shillong to 273.4 cm at Dalu (CWC, 2(b), Annex 4.1), and the monsoon rainfall "varies from 100 cm in the west central part to over 1000 cm in the south and southeast" (CGWB); the annual figures of 11,430 mm for Cherrapunji and 17,800 mm for Mawsynram quoted by CGWB give no source or period and are not normals. The antecedent moisture rule of Clause 2.11.4 and the standby period of Chapter 10 refer to this season.
Storms outside the season Large falls come before and after the season, and the October storms that come about the time of the withdrawal fall inside it. Cherrapunji's highest days outside the season are 587.4 mm in March (23 March 1994), 376.9 mm in February (18 February 1993), 332.2 mm in November (1917) and 189.7 mm in December (1926); Shillong's are 48.0 mm in February (28 February 1973) and 138.2 mm in November (16 November 2007) (IMD, Extremes). In October, about when the south-west monsoon withdraws, Cherrapunji recorded 594.0 mm on 11 October 1975 and Shillong 262.0 mm on 8 October 2004, and the Garo Hills floods of 4–6 October 2024 came in IMD's post-monsoon season (IMD; as reported). The winter is close to dry, and December to February is this Manual's works window. Design statistics use annual maxima from all months, no works deadline or operating rule shall assume that heavy rain is confined to June–September, and the works calendar of Chapter 10 keeps standby to 31 October and a post-season clearance by 15 November for this reason.
Climate factor (CF) Multiplier applied to present-day design depths to represent the design-life climate.
Approved source A rainfall source listed in Clause 2.3.

2.3 Approved sources of design rainfall

2.3.1 Primary source. Design rainfall depths and intensities shall be taken from the National Institute of Hydrology, Roorkee NIH-DHAARA platform (Design Hydrology and Advanced Rainfall Analysis, nihdhaara.in). Use its IDF / frequency tools for the site's coordinates, for each duration and AEP required by Clause 2.4. In Meghalaya this clause is suspended until Annex 2A is published: Clause 2.3.6 sets the interim source.

2.3.2 Station IDF. A station-specific IDF relationship may be used in place of 2.3.1 only if all of the following hold:

  • (a) it is derived from at least 30 years of recording-gauge (hourly or finer) data;
  • (b) it has been published or approved by IMD, the State Hydrology Authority or the approving authority; and
  • (c) the gauge is within 10 km of the site, with no major change of terrain or coastal exposure in between.

Where a station IDF is used, the design value shall be the greater of the station value and the NIH-DHAARA value.

2.3.3 Cross-checks (mandatory, not alternatives). The designer shall report, but need not adopt, the following values for comparison:

  • (a) the IMD isopluvial / IDF values of Das et al. (2022), MAUSAM 73(4), for durations of 1–24 h;
  • (b) for catchments of 25–5,000 km², the 24-hour point rainfall from the CWC Flood Estimation Report for subzone 2(b) (South Brahmaputra), which covers the northern foothills, the plateau and the interior of the Garo hills but not the southern escarpment and the south Garo slopes, which lie in subzone 2(c) (Barak), for which CWC has published no Flood Estimation Report, as applicable.

Where the design value is lower than the CWC subzone 2(b) (South Brahmaputra) plate (outside the Shillong Planning Area, where Clause 2.3.6(c)(i) sets the floors instead, and outside sub-areas ML-C and ML-C1, which no CWC plate covers) value for the same AEP, the CWC value shall be adopted as a floor.

2.3.4 Not permitted. None of the following shall be used as a design rainfall source:

  • (a) generalised all-India IDF formulae (for example Kothyari & Garde, 1992);
  • (b) rainfall values that cite no source, including vendor or web-calculator tables;
  • (c) single-event maxima; or
  • (d) design intensities carried forward from a previous project without a stated AEP.

1. Station IDF (none yet) ≥25 yr SRRG/AWS, ≤10 km, same sub-area, not across a ridge or plateau edge (a) Otherwise, by zone of Annex 2A ML-Z1, ML-Z2 (not Shillong), ML-Z4 CWC 2(b) plates (c); × 2(b) ratios in the foothills, × 2(a) on the plateau and Garo hills (f) Shillong Planning Area (c)(i) IMD Shillong Gumbel; ≥437 mm (1%), ≥357 mm (2%); plate not used; × 2(a) ratios; 1-h floor ML-Z3 escarpment (c)(ii) IMD Das (2022) Cherrapunji curve; 2(c) has no CWC report; site study >1 km² Take the greater per AEP and duration (with the floors of (c)(i), (g)) IMD station annual maxima 2–25 yr 24-h depths (Cl. 2.3.6(d)) 24-h record check (h) ≤25 km, same sub-area, no ridge or plateau edge between NIH-DHAARA (m) ML-A, ML-B, ML-B1 comparison only IMD Das (2022) Shillong panel generic curve: not used (n) report Adjustments, in order 1. Fixed-interval → true-interval (Cl. 2.6.3) 2. Grid → point, if grid values (Cl. 2.7.1) 3. Areal reduction, >10 km² only (Cl. 2.7.3) 4. Climate factor 1.20 / 1.10 (Cl. 2.8) → Design depth → hyetograph (Cl. 2.9) Meghalaya (Cl. 2.3.6): no station IDF yet; 2(b) plates outside Shillong and ML-Z3; Shillong rule; Das Cherrapunji curve in ML-Z3; bounded record check.

Figure 2.1 — Design rainfall source hierarchy and adjustment sequence. Original drawing for this Manual.

2.3.5 Version control. Every submittal shall record the source, its version or access date, the coordinates queried, and the values extracted (Clause 2.13).

2.3.6 Interim source in Meghalaya. Until Annex 2A is published and confirms NIH-DHAARA, or an approved station IDF, for a zone, Clause 2.3.1 does not apply in Meghalaya, and design rainfall shall be taken as follows:

  • (a) Station IDF. Where a station IDF fitted to a checked IMD recording-gauge (SRRG) or automatic weather station record of at least 25 years has been published in Annex 2B, it governs, within 10 km of the station and in the same sub-area of Annex 2A, for the durations and AEPs it covers, in place of (f), and subject to the floors of (c)(i) and (g); the comparison of Clause 2.3.2 is then made with the 24-hour and longer depths of (c) to (e) and (h), and the CWC floor of Clause 2.3.3 still applies outside the Shillong Planning Area and outside sub-areas ML-C and ML-C1. A record is checked when its annual totals and annual maxima have been compared with the IMD normals and station extremes for the station, and every year that disagrees has been explained or removed. An IDF derived from daily data by the one-third rule (Clause 2.6.4) or by any other fixed ratio is not a station IDF. In Meghalaya Clause 2.3.2(a) is read with 25 years in place of 30, as in the mountain editions of this series, and the gauge shall not be separated from the site by a ridge or by the edge of the plateau (set by this Manual, because the State's rain changes several-fold over a few tens of kilometres: the highest day printed by IMD is 1,563.0 mm at Cherrapunji and 273.2 mm at Shillong, about 36 km apart (IMD, Extremes; distance a NEER reading)). No IDF has yet been published in Annex 2B, and no station IDF with constants was found for any station in the State: no IDF study of NEHU, IIT Guwahati, NIT Meghalaya or NERIST with published constants was found [TBC]; the "Eastern" constants of the zonal equations of Ram Babu et al. (2006) repeat the "Central" ones, a typesetting duplicate (NEER reading), and are not used (o); and IMD Das et al. (2022) has a genuine panel only for Cherrapunji (n). The first data request of this Manual is for the IMD recording-gauge and automatic weather station annual maxima and return-period tables of Cherrapunji (Sohra, 42515) and Shillong (C.S.O.) (42516), the State's two stations in IMD's Extremes, to be fitted under this paragraph; then for Jowai or Khliehriat, whose plate value under (c) is probably high, Mawsynram, Barapani/Umiam (the agro-meteorological station of the ICAR Research Complex for NEH Region [TBC]), Tura, Shella, Nongstoin, Williamnagar, Baghmara and the gauges of the Dawki area; then for the other gauges on the daily rainfall map of the Meteorological Centre Shillong, among them Tikrikilla, Resubelpara, MeECL Lumjingshai, Mawphlang, Mawkyrwat, RKM Sohra and Ratacherra, whose types and record lengths are to be confirmed [TBC]; and for the hourly data of 15–17 June 2022, 4–6 October 2024 and June 2026.

  • (b) Reports, zones and sub-areas. Two CWC areas cover the State. The northern foothills, the plateau and the interior of the Garo hills lie in subzone 2(b), South Brahmaputra, whose revised report (Design Office Report No. SB-2(b)/R-4/44/99, March 2000, approved by the Flood Estimation Planning and Co-ordination Committee at its 55th meeting on 13.3.2000, revising SB/8/1984) describes the subzone as bounded "on the south by Barak Subzone 2 (c)" and names Shillong and Tura among its towns (CWC, 2(b), p. 18). The southern escarpment facing Bangladesh, with Sohra, Mawsynram, Shella, Pynursla, Dawki and Baghmara, lies in subzone 2(c), Barak, for which CWC has published no Flood Estimation Report: the 2(b) report lists the 21 reports published by 2000 and none is for 2(c), and CWC's page of its reports, as captured on 20 March 2024, lists none (CWC). No part of the State lies in subzone 2(a), North Brahmaputra, on the north bank of the Brahmaputra; its report is used in (f) for its ratios only. On Plates 8 to 10 of the 2(b) report the dashed subzone boundary runs west–east along the plateau, just south of Shillong and on or just north of Tura, and no contour is drawn south of it west of about 91.8° E (NEER reading of the plates, about one town marker either way) [TBC]. The rainfall zone and sub-area of the site are those of Annex 2A: zone ML-Z1 Northern foothills, with sub-areas ML-A Northern foothills and Ri-Bhoi (Nongpoh–Umsning–Byrnihat–Umiam) and ML-A1 Garo foothills and plains (Resubelpara–Mendipathar–Tikrikilla–Phulbari); zone ML-Z2 Plateau, with sub-areas ML-B Shillong plateau (Shillong–Mawphlang–Nongstoin–Mairang) and ML-B1 Jaintia hills karst and mine belt (Jowai–Khliehriat–Sutnga–Ladrymbai); zone ML-Z3 Southern escarpment, with sub-areas ML-C Southern escarpment (Sohra–Mawsynram–Shella–Pynursla–Dawki) and ML-C1 South Garo slopes (Baghmara–Siju–Gasuapara); and zone ML-Z4 Garo hills, with sub-area ML-D Garo hills interior (Tura–Williamnagar–Rongjeng–Ampati–Dalu). ML-Z1 and ML-Z2 lie in subzone 2(b), ML-Z4 on the boundary of 2(b) and 2(c), and ML-Z3 in subzone 2(c). They fix the source of (c), the ratios of (f), the floors of (g), the bounds of the check of (h) and the rule of (i). A catchment that crosses the line between two zones or two sub-areas of Annex 2A takes, at every duration, the higher value of the two (set by this Manual). The town lists of Annex 2A are a guide; their boundaries, and the side of the 2(b)/2(c) line on which Khliehriat, Mawkyrwat, Dalu and Ampati lie, are to be confirmed [TBC].

  • (c) 24-hour depth, 2% and 1% AEP (50- and 100-yr). Outside the Shillong Planning Area and outside sub-areas ML-C and ML-C1, the 24-hour point value at the site read from the 50- and 100-year isopluvial plates of the 2(b) report (Plates 9 and 10), whatever the catchment area. Where the site lies between two contours, the higher contour value is used; where it lies inside a closed contour with no higher contour within it, the value is that contour plus one contour interval, except that a contour that closes on the subzone boundary is read at its own value; and where the plate cannot be read at the site, the highest contour legible within 25 km of the site and in the same sub-area is used until the plate has been read for it [TBC] (all set by this Manual). The contours in this sector are 320, 400, 480, 560 and 680 mm, at intervals of 80–120 mm. Plates are read by the coordinates of the site, not by the town labels; on the copy used for this Manual the town markers fitted to the graticule fall about 20 px from the printed town dots on Plate 8 and about 0.15° from them on Plate 10, so those plates were read from the printed dots, and each reading is recorded on Form 2-1 with the contours on either side. For orientation only, read by eye to about one contour (low confidence), the 50-year plate gives about 560 mm at Shillong (560–680 mm at 100 years); about 680 mm at Jowai, inside a closed 680 mm tongue that closes on the subzone boundary and is therefore read as 680 mm, not 680 mm plus one interval; about 560 mm at Nongstoin; about 280–320 mm at Nongpoh; about 320–400 mm at Tura, which lies in a closed 320 mm cell on Plate 8; and about 400 mm at Williamnagar. It is blank at Sohra, Mawsynram and Baghmara, and at Dawki the contours of the Jaintia south, extrapolated across the boundary, give about 560–680 mm (very low confidence) (CWC, 2(b), Plates 8–10; NEER reading). Where the Gumbel estimate of (d) for the station of the site is higher for the same AEP, it governs; the 24-hour depth is then checked under (h). At Jowai and Nongstoin the plate is probably high: NIH-DHAARA gives 335 mm and 285 mm at 50 years there (m), and Jowai's gauge is a priority of (a). Two departures from the plate are set by this Manual:

    • (i) Shillong. Within the Shillong Planning Area, the 288.5 km² of the Shillong Master Plan 2041 (NESAC, 2023), the plates are not used for design, because Plate 9 reads about 560 mm at 50 years, 1.3 to 2 times every fall recorded at any Shillong gauge: 273.2 mm at Shillong (C.S.O.) on 25 June 1988, in IMD's record of 1957–2012 (IMD, Extremes); 347 mm in 24 hours on 14–15 September 1960 at the Shillong recording gauge of the 2(b) report (CWC, 2(b), Annex 4.2); and 415 mm at Shillong (Obsy) and 437 mm at Upper Shillong, both on 20 June 1934 (CWC, 2(b), Annex 4.1). NIH-DHAARA gives 246 mm at 50 years and 276 mm at 100 years in the Shillong cell (m). The plates' 680 mm tongue just south-east of the town suggests that they carry the escarpment's values north over the plateau (NEER reading). Within the Shillong Planning Area the 24-hour depth at every AEP is therefore the Gumbel estimate of (d) from the daily annual maxima of IMD Shillong (C.S.O.), with 30 or more years of record (IMD's data period is 1957–2012), and not less than 437 mm at 1% AEP, the largest fall printed for any Shillong gauge (Upper Shillong, 20 June 1934), and 357 mm at 2% AEP, which is 437 mm less one 80 mm contour interval of the plates. The 25-year plate floor of (d) does not apply there, and the CWC floor of Clause 2.3.3 is not applied there. The plate value and the NIH-DHAARA value are recorded on Form 2-1 beside the design depth. This is a departure below the CWC plate, made because the plate stands at about twice the town's records; the two floors keep every design depth above every fall recorded at any Shillong gauge (all set by this Manual).
    • (ii) Southern escarpment. In sub-areas ML-C and ML-C1 no CWC plate applies: the escarpment lies in subzone 2(c), which has no report, and the 2(b) plates draw no contour there west of about 91.8° E. There the Cherrapunji curve of IMD Das et al. (2022), Fig. 4(v), is the interim design rainfall at every AEP and every duration it covers, read as in (f), in place of (c), (d) and (f) (set by this Manual, because no CWC report, no plate contour and no other station series exists for the escarpment, and because its flood yields show escarpment-scale rain well east of Sohra: the spillway of Myntdu–Leshka Stage I passes 12,000 m³/s from a catchment of 350 km², about 34 m³/s per km², against 3,820 m³/s from 1,020 km², about 3.7 m³/s per km², at New Umtru on the northern slope (MePGCL; ratios a NEER reading)). The curve may be replaced only by a station fit under (a), or by a site-specific study from the gauges of the Meteorological Centre Shillong agreed with the Authority and recorded on Form 2-1, and never by values below those of the adjoining 2(b) sub-area for the same AEP and duration. The panel is used for no town outside ML-Z3. Every cross-drainage structure and outfall in ML-Z3 with a catchment of more than 1 km² also has the site-specific study of (i).
  • (d) 24-hour depth, 50%, 20%, 10% and 4% AEP (2-, 5-, 10- and 25-yr). The depth is the Gumbel (EV1) estimate from the annual maximum daily rainfall series, of all months, of the IMD station agreed with the Authority, with 30 or more years of daily record, checked as in (a), multiplied by the fixed-interval factor of Clause 2.6.3; outside the Shillong Planning Area and ML-Z3 the 4% AEP depth is not less than the 25-year plate value (Plate 8) read as in (c) (set by this Manual). The station is Shillong (C.S.O.) for the Shillong Planning Area and sub-area ML-B, and Cherrapunji for sub-area ML-C where a station fit is made under (c)(ii); for the other sub-areas it is agreed with the Authority from the gauges of (a), whose record lengths are to be confirmed [TBC]. No Gumbel fit to the annual maxima of any station in the State was found for this Manual [TBC]. A day of record excluded under (h) is left out of the series, and the fit with it is reported beside the fit without it on Form 2-1 (set by this Manual). The largest 48-hour fall reported for the State, 2,493 mm at Cherrapunji on 15–16 June 1995, recognised by WMO as a world record (as reported), is not a value printed by IMD: it is reported on Form 2-1 as the stress case for cross-drainage structures and outfalls in ML-C, not as a design value.

  • (e) 48- and 72-hour depths. The Gumbel estimate from the annual maximum 2-day and 3-day rainfall series of the same station, with the fixed-interval factors of Clause 2.6.3, and not less than the 24-hour depth for the same AEP, as checked under (h). In ML-Z3, until a station fit is made, they are those of the study of (i), and not less than the 24-hour depth of (c)(ii) [TBC].

  • (f) Durations of 1 to 24 hours. The 24-hour depth of (c) or (d), before the check of (h), multiplied at every AEP by the ratios in Table 2B.1 for the site's sub-area, or in ML-Z3 the depths of the Cherrapunji curve (all set by this Manual):

    • in sub-areas ML-A (Northern foothills and Ri-Bhoi) and ML-A1 (Garo foothills and plains), the ratios of the 2(b) report: 0.48 at 1 hour, 0.62 at 3 hours, 0.74 at 6 hours, 0.81 at 9 hours, 0.87 at 12 hours, 0.91 at 15 hours and 0.95 at 18 hours, the 10-year ratios averaged over the six recording gauges of the report, Shillong and five in the Assam valley (CWC, 2(b), Table 4.1);
    • in sub-areas ML-B (Shillong plateau), ML-B1 (Jaintia hills karst and mine belt) and ML-D (Garo hills interior), the ratios of the CWC report for subzone 2(a), North Brahmaputra: 0.260 at 1 hour, 0.370 at 2 hours, 0.457 at 3 hours, 0.615 at 6 hours, 0.720 at 9 hours, 0.805 at 12 hours, 0.875 at 15 hours and 0.930 at 18 hours, averaged over the frequency analyses of 12 IMD recording gauges and printed for the 50-year depth (CWC, NB/18/1991, §3.1.2, p. 24, and Fig. 10, which gives the 2-hour value); and
    • in sub-areas ML-C (Southern escarpment) and ML-C1 (South Garo slopes), the Cherrapunji curve of IMD Das et al. (2022), Fig. 4(v), read for every AEP and duration it covers: by eye, about 75, 117, 146, 182, 208 and 236 mm/h at 1 hour and 17, 31, 40, 51, 60 and 68 mm/h at 24 hours for 2, 5, 10, 25, 50 and 100 years, that is 24-hour depths of about 410, 745, 960, 1,225, 1,440 and 1,630 mm and a 1-hour ratio of about 0.14 at 50 and 100 years (readings ±5 mm/h at 1 hour and ±3 mm/h at 24 hours; NEER reading).

    The 2(b) ratios are kept for the northern foothills, which face the Assam valley whose convective gauges the ratio was built from; the single-event 1-hour ratios of the report's recording gauges in the Assam valley run from 0.21 to 0.50 (CWC, 2(b), Annex 4.2). They are not used on the plateau: applied to the Shillong plate, 0.48 gives about 269 mm in 1 hour, 5.6 times the 48 mm that the Shillong recording gauge recorded in its largest hour (15 September 1960; CWC, 2(b), Annex 4.2). Shillong's own single-event ratios are 0.14 at 1 hour, 0.32 at 3 hours, 0.48 at 6 hours and 0.64 at 12 hours (the storm of 14–15 September 1960), NIH-DHAARA's Shillong cell gives 0.23 and the Das et al. (2022) Cherrapunji panel about 0.14: the plateau's 24-hour totals are long orographic falls, more so than on the orographic fronts of the mountain editions of this series. Shillong's own 0.14 is not used either, because it comes from one storm at a gauge whose record length is not printed. The 2(a) set has the lowest 1-hour ratio of the CWC reports compared for this Manual (2(b) 0.48, zone 7 0.425, 1(g) 0.35, 1(e) 0.34, 2(a) 0.26) and lies above every observation on the plateau at every tabulated duration (0.26 against 0.23 and 0.14 at 1 hour, 0.457 against 0.32 at 3 hours, 0.615 against 0.48 at 6 hours and 0.805 against 0.64 at 12 hours). On the Shillong floors of (c)(i) it gives about 114 mm in 1 hour at 1% AEP and about 93 mm at 2% AEP, about twice the recorded hour and NIH-DHAARA's 56 mm at 50 years, the same conservative margin that the mountain editions accepted on their orographic fronts. On Jowai's plate value of about 680 mm it gives about 177 mm in 1 hour at 50 years; that is probably high, and is why Jowai's gauge is a priority of (a). In ML-Z3 the Cherrapunji curve is the one genuine panel for the State: its curves bend between 9 and 12 hours, and the paper says that the region's values are highest "within the nearby periphery of Cherrapunji station and then sharply decreases away" (IMD Das et al., 2022, pp. 894–896). Its 1-hour values have no gauge check, because no hourly maximum for Cherrapunji or Mawsynram was found, and the record length behind the panel is not printed [U]. Between the tabulated durations the ratio is interpolated on logarithmic axes; the 2-hour ratio of 2(b), which the report does not give, is interpolated in the same way.

  • (g) Short storms. No absolute floor in millimetres is set for any sub-area of the State, because the ratios and the curve of (f), applied to the depths of (c), already give 1-hour depths at or above the hours of record. Two floors guard against lower values where a station analysis or study governs (all set by this Manual):

    • (i) Shillong. Within the Shillong Planning Area the 1-hour depth for every AEP shall be not less than 48 mm multiplied by the ratio of the 24-hour depth of (c)(i) for that AEP to the 24-hour depth for the 10% AEP (10-yr), before the check of (h); that is, the largest hour of the Shillong recording gauge, 48 mm on 15 September 1960 (CWC, 2(b), Annex 4.2), is treated as the 10-year 1-hour depth and scaled to the other AEPs by the growth of the 24-hour depths, until the IMD Shillong recording-gauge and automatic weather station series is fitted under (a). The gauge's record length is not printed in the 2(b) report [TBC], which is why its largest hour is treated as a 10-year depth. With the 2(a) ratio the floor binds only where the 10-year 24-hour depth used is below about 185 mm (48 mm ÷ 0.26; NEER arithmetic); it guards against a light station fit.
    • (ii) Southern escarpment. In ML-C and ML-C1, where a station fit or a study replaces the Cherrapunji curve under (c)(ii), its 1-hour depth for every AEP shall be not less than 0.14 times its 24-hour depth for the same AEP, the curve's own ratio at 50 and 100 years.

    Where a floor of this paragraph governs the 1-hour depth, the 2-hour depth shall be not less than the value interpolated on logarithmic axes between the 1-hour and 3-hour depths for the same AEP. The floors are present-day, true-interval values: the fixed-interval factor of Clause 2.6.3 is not applied to them, and the climate factor of Clause 2.8 is. They are interim, to be revisited when Annex 2B publishes frequency analyses of the recording-gauge and automatic weather station records of the stations of (a), beginning with Cherrapunji and Shillong: if any shows 1- or 3-hour depths above those of (f) and (g) for a sub-area, a floor shall be set or raised for it; if together they show depths well below them, a reduction may be proposed to the State Stormwater Technical Committee. The depths of (f) and (g) are present-day, true-interval values once the fixed-interval factor has been applied to the 24-hour depth; the climate factor of Clause 2.8 is then applied.

  • (h) 24-hour record check, bounded by sub-area. The 1% AEP (100-yr) 24-hour depth of (c) or (d) shall be not less than the highest qualifying 24-hour rainfall recorded at any station within 25 km of the site, in the same sub-area of Annex 2A and not separated from the site by a ridge or by the edge of the plateau, where that record is higher; the record is used as printed, without the fixed-interval factor, and is treated as a 1% AEP depth; the 2% AEP (50-yr) 24-hour depth is then not less than the 1% AEP depth so raised less one contour interval of the plates, 80 mm (all set by this Manual). The radius of the mountain editions does not transfer to Meghalaya on its own: with 25 km and no other limit, Cherrapunji's 1,563.0 mm would set the 100-year depth at Mawphlang and Laitkor on the edge of the plateau, whose climate is the plateau's; Shillong itself lies about 36 km from Sohra and 42 km from Mawsynram (NEER distances). Sohra's record never reaches sub-area ML-B. A record qualifies only when it is printed by IMD (in Extremes of Temperature and Rainfall for Indian Stations, a climatological summary of the State, a monthly or seasonal climate summary, a later IMD table or an IMD press release that names the gauge and the day) or in Annex 4.1 or 4.2 of the 2(b) report, which CWC prepared jointly with IMD, RDSO and the Ministry of Surface Transport; the number of years of data at its gauge is confirmed by an IMD table as at least 20; it was made in 1901 or later, or IMD has confirmed that the gauge that made it stood where the present gauge stands and was read in the same way; it falls in a month in which a fall of that size is plausible for the station; the location of its gauge is known; and it is not contradicted by another IMD table for the same gauge. A record that fails any test is excluded until IMD confirms what it lacks (set by this Manual). The outcomes at present are:

    • Cherrapunji, 1,563.0 mm on 16 June 1995 (IMD, Extremes, rainfall data 1902–2012; the press figure of 1,563.3 mm is not used), qualifies, and sets the 1% AEP 24-hour depth at not less than 1,563.0 mm within 25 km of the gauge in sub-area ML-C. The curve of (c)(ii) already gives about 1,630 mm at 100 years, so the record raises nothing unless a station fit or study under (c)(ii) comes in lower.
    • Mawsynram, 1,003.6 mm in the 24 hours to 08:30 IST on 17 June 2022, qualifies. IMD prints it as a 24-hour record for June, against a previous June record of 945.4 mm on 7 June 1966 (IMD, Monthly Climate Summary, June 2022; the 944.7 mm of the press is not used), so its table shows the gauge to have more than 20 years of record, as the mountain editions read IMD's tables of previous records. IMD marks the 2022 value as based on real-time data, and does not say whether it is Mawsynram's highest day in any month [U]. It lies below the values of (c)(ii) and raises nothing.
    • Shillong (C.S.O.), 273.2 mm on 25 June 1988 (IMD, Extremes, rainfall data 1957–2012), qualifies, and lies below the floors of (c)(i).
    • Excluded pending confirmation [TBC]: the 347 mm of the Shillong recording gauge on 14–15 September 1960 (CWC, 2(b), Annex 4.2), because IMD's Shillong series, which begins in 1957, prints 273.2 mm as its highest day, so the two contradict each other unless they belong to different gauges or windows [U]; 437 mm at Upper Shillong and 415 mm at Shillong (Obsy) on 20 June 1934, and 320 mm at Dalu on 13 June 1956 (CWC, 2(b), Annex 4.1), whose gauges' years of record are not confirmed by an IMD table read for this Manual (437 mm is still the floor of (c)(i), which does not depend on this test); and the 811.6 mm (also printed as 811.2 mm) and 972 mm reported at Sohra for the 24 hours to 08:30 IST on 15 and 17 June 2022, which the press attributes to IMD but which were not found in an IMD table (as reported; the two figures for 15 June conflict).

    Until Annex 2A is published, the designer lists on Form 2-1 every record within 25 km of the site, with its sub-area and the tests it passes or fails. The check raises the 24-hour depth and, through (e), the 48- and 72-hour depths. It does not raise the depths of (f) and (g) for 1 to 18 hours, because the records are daily totals of long orographic storms and no hourly record of any of them exists.

  • (i) Hazard-first catchments. Meghalaya has no snow-fed catchment. The design is hazard-first at every site in ML-Z3, and at any site in another sub-area that lies below a mapped landslide zone, a debris fan, a mine-spoil dump, a karst sink or cave entrance, or on the release reach of a reservoir of MePGCL (Umiam, Kyrdemkulai (Stage III), Nongkhyllem (Stage IV), New Umtru and Myntdu–Leshka): no design there is complete without a screening, recorded in the drainage report, that identifies them, from the landslide and flash-flood susceptibility maps of the NESAC risk-informed master plans and of the IRADe/NMHS plan for Shillong, the inventories of MSDMA where they exist [TBC] and the release reaches in MePGCL's gate-operation guidelines, and states whether the site lies on their path; where it does, the siting, setback and floor-level rules of Chapters 6 and 7 govern, because no drain is sized to carry a debris flow (set by this Manual). In ML-Z3 every cross-drainage structure and outfall with a catchment of more than 1 km² has a site-specific hydrology study, agreed with the Authority and recorded on Form 2-1: no CWC unit hydrograph applies in subzone 2(c); losses are taken as near zero in the monsoon season; multi-day storms are routed through the structure, because on the escarpment duration and volume govern culverts and outfalls, not only the peak; and the design rainfall is that of (c)(ii) (set by this Manual). The escarpment's disasters are as much slides and debris as rain: the earthquake of 12 June 1897 brought down a landslide at Sohra in which 600 people were reported killed, the Shillong–Dawki road collapsed at Laitlyngkot in June 2026, and the NH-6 tunnel at Sonapur was closed by mudslides in August 2023 (all as reported).

  • (j) Cloudbursts. IMD calls a fall of 100 mm or more in one hour over a small area a cloudburst (as quoted; no IMD primary document was found for this Manual [TBC]). No design rule is drawn from the term. The press calls Meghalaya's storms "cloudbursts" ("Meghalaya lost 13 lives following incessant cloudbursts", 2022, as reported) without measured hourly rates, and the only hour recorded at any gauge of the State in a primary source is Shillong's 48 mm (15 September 1960; CWC, 2(b), Annex 4.2). The 50-year 1-hour depth of the Cherrapunji curve, about 208 mm, is twice that threshold, so the design already covers such bursts on the escarpment; on the plateau the 1-hour depths of (f) on the Shillong floors, about 93–114 mm before the climate factor, are of the same order as the threshold. What a burst does in a steep catchment that a design storm does not represent is to bring down boulders, slope debris and garbage in its first minutes; in such catchments the capacity of inlets, debris racks and culverts to stay open governs more than the conveyance of the drain, and Chapters 6 and 9 size them for it.

  • (k) Durations below 1 hour. No sub-hourly frequency analysis for any station in the State was found in research for this Manual. Until Annex 2B gives one, the ratio of the depth for a duration below 1 hour to the 1-hour design depth is agreed with the Authority, from a published recording-gauge analysis whose source is stated, and recorded on Form 2-1 [TBC]; the average intensity for a duration below 1 hour shall be not less than the 1-hour design intensity for the same AEP (set by this Manual). The time distribution of storms in the 2(b) report (Annexure 4.4) was not extracted for this Manual [TBC].

  • (l) Order of depths. For the same AEP, no depth shall be less than the depth for a shorter duration.

  • (m) NIH-DHAARA. NIH-DHAARA was queried at ten points in the State on 14 November 2026 (IMDAA dataset). In sub-areas ML-A, ML-B and ML-B1 its present-day values at the site are reported on Form 2-1 beside the interim values, for comparison only; they are never a design value, a floor or a check. Its 50-year 24-hour depths there are 246 mm at Shillong, 207 mm at Nongpoh, 285 mm at Nongstoin and 335 mm at Jowai. In ML-A1, ML-C, ML-C1 and ML-D it is not used or reported, because its cells there are erratic: 1,423 mm at Dawki, more than the 1,029 mm of the Mawsynram cell; 624 mm at Tura, against a plate value of about 320–400 mm and Dalu's 320 mm; 936 mm at Baghmara and 860 mm at Williamnagar, with no gauge to check them; and 922 mm at Sohra, below the curve of (c)(ii), about 1,440 mm (NIH-DHAARA, queried 14 Nov 2026). Its projected depths are not used under Clause 2.8.4.

  • (n) IMD Das et al. (2022). The paper has two panels for the State. The Cherrapunji panel (Fig. 4(v)) is a genuinely different curve and is used in ML-Z3 under (c)(ii) and (f). The Shillong panel (Fig. 4(xxv)) repeats the generic curve that the paper prints for most of its cities, about 60, 73, 82, 93, 101 and 109 mm/h at 1 hour for 2 to 100 years, and is not station data: it is not used as a value, a check or a floor anywhere, and outside ML-Z3 the cross-check of Clause 2.3.3(a) is recorded on Form 2-1 as not available.

  • (o) Earlier design values. No design storm, return period, runoff coefficient or drain standard was found for the drains of any town in the State. The one method found is that of RMSI's multi-hazard risk and vulnerability assessment of Shillong (2019), which used "the IMD rainfall station at Shillong", with design rainfall "adopted from the Brahmaputra Basin PMP Atlas developed by the Central Water Commission (CWC, 2014) using data from 1957-2010", and the rational formula, for return periods of 2 to 100 years (as quoted in the IRADe/NMHS plan, 2020; the RMSI report and the atlas were not obtained [TBC]); a designer who uses the atlas reports its values on Form 2-1, with the station and period. The 148.91 km of Shillong's drains state no design storm (Smart City Proposal 2016-17, as quoted in the IRADe/NMHS plan). Road drains follow IRC:SP:42-2014 and IRC:SP:48 (Chapter 6). The zonal IDF equations of Ram Babu et al. (2006) are generalised formulae under Clause 2.3.4(a), and their "Eastern" constants repeat the "Central" ones, so they are not used. The return periods of Table 2.1 and the depths of this clause apply.

  • (p) Other clauses. Where Clauses 2.3.2, 2.6.1, 2.7.1 and 2.13, Annexes 2A to 2C and Form 2-1 refer to the NIH-DHAARA value, the value under this clause is meant.

Commentary. NIH-DHAARA is a national, publicly accessible product from a Government of India institution, and it can be queried at any point in the State. That makes it a reproducible default that an approving authority can check. NIH-DHAARA's sub-daily values are derived from hourly records, not disaggregated from daily totals. That makes it the only public source suitable for sizing drains, which depend on short-duration intensity. Its values should still be checked against the long IMD daily record at 24 hours and longer (Annex 2A). In Meghalaya the platform has not yet been shown to meet that purpose. It was queried at ten points of the State for this Manual. On the plateau and the northern slope its cells are plausible: at Shillong its 50-year 24-hour depth, 246 mm, lies between IMD's record of 273.2 mm and the 1960 recording-gauge fall of 347 mm, and its 50-year 1-hour depth, 56 mm, is close to the 48 mm the Shillong recording gauge recorded in its largest hour. On the escarpment and in the Garo hills it is erratic: it gives Dawki 1,423 mm at 50 years, more than Mawsynram, and nearly twice Shillong's record even at 2 years (511 mm), Tura 624 mm against a plate of about 320–400 mm, and Sohra 922 mm against about 1,440 mm on the IMD Cherrapunji curve; there it errs high in some cells and low in others, unlike the hill cells of the mountain editions, which broke down only at short durations. A source that fails a check in part of the State cannot be adopted for any of it, so Clause 2.3.6 uses the CWC reports, the IMD station records and the one genuine IMD curve for the State until Annex 2A has been done, and reports NIH-DHAARA beside the design values on the plateau and in the northern foothills of Ri-Bhoi only. The Shillong panel of IMD Das et al. (2022) is not used anywhere, because it repeats the generic curve that the paper prints for most of its cities; the Cherrapunji panel, by contrast, is a curve of its own. Meghalaya is the first North-East hill edition of the series, and three things set its interim source apart. First, two CWC subzones cover the State and only one has a report: the 2(b) report of 2000 covers the plateau, the northern foothills and the Garo hills, while subzone 2(c), Barak, which holds the southern escarpment and the record-rainfall belt of Sohra and Mawsynram, has none, and the 2(b) plates stop at the boundary. The 2(b) report's gauges are mostly in the Assam valley: its six recording gauges are Shillong and five valley stations, and the two bridge catchments of its unit hydrograph that rise in Meghalaya, the Digaru and the Dudhnai, are gauged in Assam (CWC, 2(b), Annexes 3.1 and 4.2; where they rise is a NEER reading). Second, the 2(b) plates overstate the plateau. At Shillong the 50-year plate value, about 560 mm, is about 1.6 times the largest recording-gauge fall (347 mm, 1960), 1.3 times the largest fall printed for any Shillong gauge (437 mm at Upper Shillong, 1934) and twice IMD's record (273.2 mm, 1988), and the plate's 680 mm tongue round Jowai is drawn as if the escarpment's rain continued north of the boundary. Clause 2.3.6(c)(i) therefore replaces the plate inside the Shillong Planning Area by the IMD station with floors of 437 mm and 357 mm, a departure below the CWC value that keeps every design depth above every recorded fall, and Clause 2.3.6(f) uses the 2(a) ratios on the plateau, because the 2(b) ratio of 0.48 applied to the plate would give Shillong an hour 5.6 times its largest recorded hour. Third, the world's wettest belt has no plate. Cherrapunji recorded 1,563.0 mm on 16 June 1995 and Mawsynram 1,003.6 mm on 17 June 2022, while Shillong, about 36 km away, has never recorded 300 mm at its IMD station (IMD). Clause 2.3.6(c)(ii) takes the IMD Cherrapunji curve as the escarpment's design rainfall, and Clause 2.3.6(h) bounds the record check by sub-area, so that Sohra's record governs the escarpment and never the plateau. What the escarpment's totals change is volume and duration more than the peak: a 1,500 mm day does not mean a 1,500 mm design depth for a drain whose time of concentration is 10 minutes, but it does mean that culverts and outfalls run near their peak for many hours, that storage fills and soils stay saturated for weeks, and that slopes and debris decide the damage, which is why Clause 2.3.6(i) asks for a site study and a duration check on every structure of more than 1 km² there. The interim rules for the more frequent AEPs, the 48- and 72-hour depths, the reading of the plates, the Shillong and escarpment departures, the sub-area of each town, the three sets of ratios, the 1-hour floors, the bounded record check, the hazard-first screening and durations below 1 hour are set by this Manual. Several points are unresolved. The plate values were read by eye, to about one contour, with town markers on Plates 8 and 10 off their printed dots, and the 2(b)/2(c) line is known only to about one marker [TBC]. The Cherrapunji curve was read by eye from a printed figure, its 1-hour values have no gauge check and the record behind it is not printed [U]. The Shillong recording gauge's 347 mm of 1960 contradicts IMD's series for the same station, and the record lengths of the 1934 and 1956 gauges of the 2(b) annex are not confirmed (Clause 2.3.6(h)). The CWC Brahmaputra Basin PMP atlas used by RMSI for Shillong in 2019, and RMSI's report, were not obtained [TBC]. No storm-drain DPR for any town of the State with its design rainfall analysis was found for this Manual [TBC].


2.4 Design return periods (summary)

2.4.1 Design AEPs are set in the chapters for each element. They are summarised here so that the correct rainfall is extracted at the start of design.

Table 2.1 — Design return periods (summary)

Element Design AEP (return period) Check event Chapter
Minor drains: Shillong, Tura and Jowai core and high-density areas 10% (10-yr) 1% (100-yr) overland path 6
Minor drains: other Class I urban areas 20% (5-yr) 1% overland path 6
Minor drains: other areas 50% (2-yr) 1% overland path 6
Arterial roads and crossings 2–4% (25–50-yr) next higher AEP 6
Collector / local roads 4% / 10% (25 / 10-yr) 2% / 4% (50 / 25-yr), plus the 1% overland path 6
Major (overland) system 1% (100-yr) — 6
Retention volume Percentile daily rainfall (Clause 2.10) — 4
Detention: standard catchments 50%, 10%, 1% (2, 10, 100-yr) 1% emergency spillway 4
Detention: flood-sensitive catchments Mixed-frequency rule, Clause 2.11 1% 4
Building floor levels 1% + 0.5 m freeboard — 6
Detention emergency spillway 1% with outlet blocked 0.2% (500-yr) where high hazard 4

Commentary. These values exceed the CPHEEO (2019) national advisory minimums of 5-yr (Class I cities) and 2-yr (other areas). CPHEEO allows a State to set higher values. The values are set in Chapters 4 and 6, and the table is reproduced here for convenience.


2.5 Design durations

2.5.1 Conveyance elements (pipes, open drains, inlets, culverts) shall be designed with the intensity for a duration equal to the time of concentration (Tc) of the contributing area (Chapter 3). The minimum duration is 10 minutes.

2.5.2 Storage elements (detention, retention, tanks, pumped sumps) shall be checked for every duration in the set {1, 2, 3, 6, 12, 24, 48, 72 h}. The largest required storage or water level governs. The 24-, 48- and 72-hour storms are mandatory checks at every site, whatever the critical-duration result.

2.5.3 Tidally influenced outfalls. For storage draining to a tidally influenced outfall (Chapter 5), the 48- and 72-hour storms shall also be run with the tailwater boundary of Clause 2.12.

Commentary. Meghalaya's worst floods have come when days of rain fill the soils and raise the streams and rivers. On the escarpment the storm of June 1995 brought 1,563.0 mm to Cherrapunji in 24 hours (IMD) and 2,493 mm in 48 hours on 15–16 June, recognised by WMO as a world record (as reported), and in June 2022 Mawsynram recorded 710.6 mm in the 24 hours to 15 June and 1,003.6 mm in the 24 hours to 17 June (as reported; IMD), in the wettest June over Assam and Meghalaya since 1901 (IMD). Cherrapunji's wettest month, July 1974, brought 6,667.4 mm, and Shillong had 1,086.8 mm in the same month (IMD, Extremes). The Garo Hills floods of September 2014 began with torrential rain on the night of 21 September and the toll was reported as 12 on 22 September and 52 by 28–29 September (as reported). The jhoras of the hill towns rise within an hour of a burst, but the landslides, the slide debris and garbage that block their culverts, and the rivers and reservoirs that hold their outfalls up are set by the whole wet spell, not its peak hour; on the escarpment duration and volume govern culverts and outfalls (Clause 2.3.6(i)). A rule based only on critical duration, applied to a small site, picks a 1–2 hour storm and misses this failure mode. That is why the long-duration checks are mandatory.


2.6 Sub-daily rainfall

2.6.1 Where NIH-DHAARA or an approved station IDF provides values directly for the required duration, those values shall be used.

2.6.2 Where only daily (24-hour) depths are available for a duration below 24 hours, the sub-daily depth shall be derived using the ratio set of Annex 2B. These are duration-to-24-hour ratios calibrated to Meghalaya recording gauges. They shall not be lower than the ratios that Clause 2.3.6 sets for the site's sub-area: those of the CWC Flood Estimation Report for subzone 2(b) in the northern foothills and the Garo plains, those of the CWC report for subzone 2(a) on the plateau and in the Garo hills, and the Cherrapunji curve of IMD Das et al. (2022) on the southern escarpment, for which subzone 2(c) has no CWC report. The subzone 2(b) ratios are not applied to plate depths on the plateau, and the IMD Das et al. (2022) Shillong panel repeats a generic curve and is not used.

2.6.3 Fixed-interval adjustment. Depths from fixed observation windows (for example 08:30–08:30 IST daily data, or clock-hour data) shall be converted to sliding-window ("true interval") depths:

  • 1.13 for a single fixed observation interval;
  • 1.04 for 2 intervals;
  • 1.02 for 3–4 intervals.

This adjustment does not apply where the approved source already gives true-interval values.

2.6.4 The empirical relationship P(t) = P(24)·(t/24)^(1/3) shall not be used for design unless Annex 2B confirms it for the zone concerned.

Commentary. The one-third power rule is common in Indian project reports, but no primary IMD source for it was found during research for this Manual. It applies one fixed curve shape everywhere: P(1h)/P(24h) = 0.35, P(3h) = 0.50, P(6h) = 0.63 and P(12h) = 0.79. It cannot represent the difference between a short convective burst and a long monsoon soak, and it tends to understate short-duration depths in convective coastal storms. Annex 2B shall tabulate the NIH-DHAARA ratios P(t)/P(24h) against these values by zone. That comparison shows whether the rule is acceptable anywhere in the State and corrects older daily-based analyses. The fixed-interval factors are the standard WMO (Hershfield) values. The IMD 2022 study applies similar clock-hour to any-hour corrections.


2.7 Point, grid and areal rainfall

2.7.1 Design depths are point values. Where an approved source provides grid-average values (for example 0.25° cells), they shall be converted to point values with the grid-to-point factors in Annex 2C before use.

2.7.2 For catchments ≤ 10 km², ARF = 1.0.

2.7.3 For catchments > 10 km², apply ARF as follows:

  • for 25–5,000 km² in subzone 2(b) (South Brahmaputra): use the ARF curves of the applicable CWC Flood Estimation Report;
  • for 10–25 km²: interpolate linearly between ARF = 1.0 at 10 km² and the CWC value at 25 km².

2.7.4 An ARF shall never be applied to storage design for a single development site.

Commentary. Gridded and district-average return levels are much lower than point values. For example, IMD gives 858.1 mm for the whole of June 2022 over its Assam and Meghalaya subdivision, the highest since 1901, while Mawsynram alone recorded 1,003.6 mm in the single day to 17 June (IMD, Monthly Climate Summary, June 2022). The NIH-DHAARA cell of about 12 km over Sohra gives 922 mm for the 50-year 24-hour depth, against about 1,440 mm on the IMD Cherrapunji point curve and the 1,563.0 mm that the Cherrapunji gauge recorded on 16 June 1995 (NIH-DHAARA, queried 14 Nov 2026; IMD). Within about 40 km the State's highest days run from 1,563.0 mm at Cherrapunji to 273.2 mm at Shillong (IMD, Extremes), a range that no cell or district average can show. Neither error can be corrected without the factors of Annex 2C. Using grid values as point values without correction would make site-level design unsafe.


2.8 Climate factor

2.8.1 Until a statewide future-climate rainfall product is adopted, present-day design depths shall be multiplied by the following interim climate factors:

Table 2.2 — Interim climate factors

Duration Climate factor (CF)
≤ 6 h 1.20
> 6 h to 72 h 1.10

2.8.2 The CF applies to all elements with a design life of more than 25 years. For temporary works (design life ≤ 5 years), CF = 1.0.

2.8.3 The climate factor does not apply to the retention depth (Clause 2.10) or to the water quality volume depth (Chapter 8). Those depths are percentile or frequent-event statistics of everyday rainfall, not AEP design values.

2.8.4 Where NIH-DHAARA, or a product adopted on review under Clause 2.14, provides projected future-climate depths, those depths shall replace the interim factors.

Commentary. CPHEEO (2019) considers a fixed climate factor "not feasible" nationally and recommends trend testing instead. That leaves designers without a usable number. The 1.20 short-duration factor matches the UK value cited by CPHEEO itself. No design uplift factor has been adopted in Meghalaya. The State Action Plan on Climate Change of 2015, as quoted in the IRADe/NMHS plan for Shillong, projects an increase in precipitation in all districts, of "only about 3%" in East and West Garo Hills and of "10-15% in precipitation by 2050" in East Khasi Hills; the same passage says that the western districts gain less than the eastern ones while naming two western districts, so its east–west wording is inconsistent as printed (IRADe/NMHS plan, 2020). The State's second action plan, for 2023–2030, was not read [TBC]; a budget note of the State summarises it as projecting "rising heavy-rainfall events" (as reported). The observed record is short and mixed: a study of Shillong's daily maxima for 1985–2003 found a "non-significant … increasing trend" (as summarised); IMD found the rainfall of June 2022 over Assam and Meghalaya, 858.1 mm, "highest since 1901" (IMD, Monthly Climate Summary, June 2022); and the monsoon of 2026 was reported 60% below normal in the State, with the lowest seasonal rainfall in 125 years over the North East and East India, yet the same season brought the Dawki flood and the Laitlyngkot collapse (as reported). The case for an uplift rests on the size of recent extremes, not on trend statistics. The factor of 1.10 for durations above 6 hours lies within the 10–15% that the 2015 plan projects for East Khasi Hills by 2050, and the factor of 1.20 for short durations above it. As in the mountain editions of this series, they are applied after the record check of Clause 2.3.6(h), including to the escarpment record where it governs, although the research for this Manual suggested leaving that record unscaled; this Manual keeps the series practice. NIH-DHAARA's projected depths are not used (Clause 2.3.6(m)). The factors of Table 2.2 are therefore interim values, not Meghalaya estimates.


2.9 Temporal patterns (design hyetographs)

2.9.1 Storms up to 24 hours. Use the nested alternating-block method:

  • construct the storm from the same IDF relationship (after the climate factor), at time steps no longer than Tc/3 and no longer than 15 minutes;
  • place the peak block at 50% of the storm duration.

2.9.2 48- and 72-hour storms (monsoon pattern). Construct as follows:

  • (a) The total storm depth equals the design depth for the full duration (48 or 72 h).
  • (b) The final 24 hours contain the 24-hour design depth for the same AEP, distributed by the alternating-block method of 2.9.1.
  • (c) The remaining depth (total minus the 24-hour depth) is spread uniformly over the preceding 24 or 48 hours.

2026-10-31T09:49:37.193022 image/svg+xml Matplotlib v3.9.4, https://matplotlib.org/ 0 6 12 18 24 Time (h) 0 10 20 30 40 50 60 70 80 Rainfall (mm per h) (a) 24-h alternating-block storm 0 12 24 36 48 60 72 Time (h) Remaining 72-h depth, spread uniformly (antecedent rain fills soils, RWH sumps, tanks) 24-h design depth on the final day (alternating block, Clause 2.9.1) (b) 72-h monsoon storm Illustrative — not design values (100-yr 24-h = 350 mm, 72-h = 520 mm, hourly blocks).

Figure 2.2 — (a) 24-hour alternating-block design storm; (b) 72-hour monsoon design storm with the 24-hour design depth on the final day. Illustrative depths only. Original drawing for this Manual. The alternating-block method follows Chow, Maidment & Mays, Applied Hydrology (1988), §14.4.

2.9.3 Other temporal patterns. Huff-type or mass-curve patterns derived from Meghalaya storms may be used instead of 2.9.1 and 2.9.2 only after they are published in Annex 2D. SCS Type I, IA, II and III distributions shall not be used.

2.9.4 Large catchments. For catchments of 25–5,000 km², the CWC Flood Estimation Report time-distribution curves may be used, and a sensitivity run with 2.9.1 shall be reported.

Commentary. The alternating-block storm embeds every shorter-duration design intensity in one hyetograph. That makes it conservative and consistent across durations. The 72-hour pattern puts the most intense day last. This reproduces the monsoon sequence of Meghalaya: by the time the largest falls arrive in June, after the storms of April and May, or in September and October, the thin soils of the plateau and the escarpment are saturated, the springs are flowing, the small reservoirs of MePGCL are releasing water through their gates, and the Umkhrah, the Umshyrpi and the rivers of the Garo plains are already high. SCS distributions are excluded because they come from US convective and Gulf storm data and have no basis in Meghalaya records.


2.10 Retention rainfall depth

2.10.1 The retention design depth is the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record, read from the zone value in Annex 2E.

2.10.2 The site must retain on site the runoff from this depth (Chapter 4). Retention earns a detention credit equal to the reduction in required detention storage found by routing with the retention in place (Clause 4.4.6). The credit is not the retained volume subtracted one-for-one.

Commentary. This follows the Kansas City Metro APWA 5600 (2025.01) Required Retention Volume concept and Georgia's 1.0-inch runoff reduction standard. Both are based on percentile storms. A percentile depth is a statistic of everyday rainfall, not an AEP value, so it is computed from the daily record rather than from the frequency curves.


2.11 Design storms for pre- and post-development comparison

2.11.1 Same storm for both scenarios. Pre- and post-development runs shall use the same design storms:

  • same AEP, duration, temporal pattern and climate factor;
  • same antecedent moisture condition (Clause 2.11.4).

The two runs differ only in land surface parameters and Tc.

2.11.2 Standard catchments. For each of the 50%, 10% and 1% AEP storms and each duration in Clause 2.5.2:

Q_post(T) ≤ 0.9 × Q_pre(T)

2.11.3 Flood-sensitive catchments (as listed in Chapter 4: the catchments of Shillong's Umkhrah and Umshyrpi, of the Umiam lake shore and the Umiam–Umtru release reaches, of Jowai on the Myntdu, of the escarpment settlements of Sohra, Mawsynram and Shella, of Dawki on the Umngot, of Tura, Williamnagar, Baghmara and Dalu on their rivers, of the Garo foothill plains on the Jinjiram and the Krishnai, and of Nongpoh–Umling on NH-6 and the Umlew, and any catchment notified by the authority). The mixed-frequency rule applies:

Q_post(1% AEP, 100-yr) ≤ Q_pre(10% AEP, 10-yr), and Q_post(50% AEP, 2-yr) ≤ Q_pre(50% AEP, 2-yr),

The post-development peak is checked for each duration in Clause 2.5.2. The caps are taken at the pre-development critical duration. The 10-yr cap is the largest pre-development 10-yr peak over all durations, and the 2-yr cap is the largest pre-development 2-yr peak over all durations. Each cap applies to every post-development duration.

2.11.4 Antecedent moisture. Use AMC III (wet conditions) for every design storm, whatever its duration, from 1 June to 15 October at a site in sub-area ML-A (Northern foothills and Ri-Bhoi), ML-A1 (Garo foothills and plains), ML-B (Shillong plateau), ML-B1 (Jaintia hills karst and mine belt) or ML-D (Garo hills interior) of Annex 2A, and from 1 April to 31 October at a site in sub-area ML-C (Southern escarpment) or ML-C1 (South Garo slopes). Use AMC III for every design storm at any time of year in a catchment that drains to a reservoir of MePGCL (Umiam, Kyrdemkulai, Nongkhyllem, New Umtru or Myntdu–Leshka) or to any other reservoir or its backwater, or to a reach below a dam into which the dam releases water. At any other site or time, use AMC III for a design storm that follows, or contains, a 5-day rainfall total of more than 53 mm. Use AMC II (average conditions) for every other storm. AMC I is not used for design.

2.11.5 Pre-development condition. Pre-development is defined in Chapter 3: greenfield, open land in good condition for the mapped hydrologic soil group. Existing impervious cover is not counted as pre-development.

Commentary. Matching each site's post-development peak to its own pre-development peak does not protect the catchment. Denver's analysis found that 100% matching at every site still produced 106% of historic peak downstream, which led to the 90% rule. The mixed-frequency rule is stricter. It caps the 100-yr post-development release at what the undeveloped site produced in a 10-yr storm. Malaysia (DID 2008: all ARIs ≤ pre-development 2-yr) is a tropical precedent for this kind of cap. AMC III for long storms reflects that monsoon extremes arrive after weeks of rain. In Meghalaya the season, the ground and the receiving waters together decide how wet a catchment is. On the escarpment the monthly totals run to thousands of millimetres, 6,667.4 mm at Cherrapunji in July 1974 and 3,961.2 mm in May 1984 (IMD, Extremes), so the thin soils over sandstone and limestone stay saturated from April to October. On the plateau, the northern foothills and the Garo hills the soils are thin red loams and sandstone soils over hard rock (CWC, 2(b), §2.3.2; CGWB), and the infiltration tests of CGWB's aquifer mapping put the share of rain that reaches the groundwater at about 4–5% on the hard rocks and the Tertiary rocks and 10–13% on the alluvium and valley fills, so that most of the rain on most of the State leaves as runoff or evapotranspiration (CGWB, GWRA 2022; recharge fractions, not infiltration rates). The reservoirs of MePGCL are small and release water through their gates often, "during Monsoon as well as during Non-monsoon period" (MePGCL), so a catchment that drains to one, or to the reach below a dam, is wet whenever the reservoir is spilling. This Manual therefore uses AMC III for every design storm from 1 June to 15 October in sub-areas ML-A, ML-A1, ML-B, ML-B1 and ML-D, the main part of the south-west monsoon; from 1 April to 31 October in ML-C and ML-C1, the whole season, because the escarpment's April and May storms are as large as most monsoon storms elsewhere; at any time of year where the outfall is a reservoir of MePGCL or another reservoir, its backwater or a release reach; and otherwise after a 5-day total of more than 53 mm, the NRCS growing-season threshold for AMC III; AMC II otherwise (Clause 2.11.4). AMC I is not used, because no part of the State is dry enough during the season to justify it. These are interim choices set by this Manual; no study in the State has yet validated AMC classes against observed runoff.

Illustrative scale of the mixed-frequency rule. The values below are not design values. They assume a 2 ha site in a colony draining to a jhora in Shillong with 24-h depths of 200 mm (10-yr) and 350 mm (100-yr), SCS-CN runoff with Ia = 0.2S, and CN 70 pre-development and CN 92 post-development:

Table 2.3 — Illustrative scale of the mixed-frequency rule (not design values)

Case Runoff depth Runoff volume (2 ha)
Pre-development, 10-yr 24 h 111 mm 2,210 m³
Post-development, 100-yr 24 h 325 mm 6,500 m³

The post-development 100-yr storm generates about three times the runoff volume of the pre-development 10-yr storm. A peak-rate cap at the pre-development 10-yr level means most of the difference must be stored and released slowly, so storage of the order of 0.2 m³ per m² of site may be needed. For this reason the rule applies only in flood-sensitive catchments (Clause 2.11.3); elsewhere the 0.9 × Q_pre rule of Clause 2.11.2 applies.


2.12 Joint occurrence with tailwater

2.12.1 For outfalls under tidal or river backwater influence, the design rainfall of this chapter shall be combined with the tailwater conditions of Chapter 5 as follows. The more severe case governs.

  • (a) Design rainfall (AEP as required) with a mean high water springs (MHWS) tailwater plus the sea-level allowance.
  • (b) A 10% AEP (10-yr) 48-hour storm with the 1% AEP still-water level (tide plus surge) plus the sea-level allowance.

Meghalaya has no coast, so no outfall in the State is tidal and cases (a) and (b) do not arise. The tailwater is the jhora, stream, river, pung, lake or reservoir into which a town drains. For an outfall under river or reservoir backwater, the site storm is combined with the receiving-water level under Clause 5.8.4, which pairs a design event on one side with a 10-yr event on the other in the same way as case (b), and the river and reservoir levels are those of Clause 5.8.2. No CWC site in the State has a warning or danger level, and none is a forecasting site. CWC monitors levels at seven sites, all classed among the south-flowing rivers, and five have a highest recorded level: the Umngot at Dawki, 73.47 m (28 May 2006); the Umnohryngkew at Therriaghat, 20.62 m (15 June 1995); the Myntdu at Kharkhana, 47.0 m (23 April 1995); the Bugi at Dimapara, 29.75 m (27 July 2007); and the Dareng at Sibbari, 20.34 m (12 August 2017); the two sites of Myntdu Stage II have none (CWC data as transcribed by SANDRP, 2018). Two of the five highest levels fell before June, on 23 April and 28 May, the reason this Manual's season begins on 1 April. There is no gauge on the Umkhrah or the Umshyrpi, which carry Shillong's drains to the Wah Roro and Umiam lake, nor on the Umiam, the Umtru, the Kynshi, the Simsang, the Ganol, the Jinjiram or the Kopili within the State, so the receiving-water level of the towns on those streams is known only from surveyed flood marks or a hydraulic model. The reservoirs of MePGCL have operator levels: Myntdu–Leshka Stage I has a full and maximum water level of 618.00 m; New Umtru a full reservoir level of 130.10 m and a maximum water level of 132.78 m; Stage IV (Nongkhyllem) 503.00 m; and Stage III (Kyrdemkulai) 2,230 ft and 2,235 ft, published in feet and converted here at 0.3048 m per foot, about 679.7 m and 681.2 m (MePGCL, gate-operation guidelines); for Umiam (Barapani), Stage I, only a full level of "3,220 ft" in the press and a spillway crest of 969.5 m in another source were found, with no datum, and no gate-operation guideline of MePGCL for it was found [TBC]. The guidelines say that, the reservoirs being small and releases frequent, notice of each release is "not practicable" and warning is given by siren, telephone or SMS (MePGCL), so outfalls on their release reaches are checked against release scenarios, not notices. Where a river leaves the State into Assam, the levels of the Assam sites govern its reach there: the Kopili at Kampur has a warning level of 59.5 m, a danger level of 60.5 m and a highest level of 61.79 m (20 July 2004), and at Dharamtul 55.0 m, 56.0 m and 58.09 m (21 July 2004) (CWC data as transcribed by SANDRP). These levels are set by rain over the catchments upstream and by the releases of the dams, and on the escarpment and the plateau the jhoras and streams rise within the hour while the storm is still falling on the town, so storage and outfalls are checked for the outfall-closed condition with the local storm falling before, during or after the stream's peak. No document found in research for this Manual sets a design receiving-water level for the outfalls of any town in the State [TBC], and Chapter 5 sets the interim rule. Every level is stated on a named datum, as Chapter 5 requires; no source found states the datum of the CWC levels quoted here, presumably metres above mean sea level [TBC].

Commentary. Meghalaya has no coast, so no outfall is tidal and there is no storm surge; the coincident load is the level of the jhoras, streams, rivers and reservoirs that receive the town drains. The coincidence is on record. In Shillong the valley floors of Polo, Pynthorbah and Nongmynsong flood "with nearly every heavy downpour" when the Wah Umkhrah, to which their drains discharge, overflows in the same storm (as reported). On 9 July 2019, when Shillong received more than 72.2 mm, Polo, Forest Colony and Mawlai flooded (IRADe/NMHS plan, Table 17). In June 2026 the Umngot at Dawki rose rapidly during the storm that collapsed the Shillong–Dawki road at Laitlyngkot (as reported), and in September 2014 the Brahmaputra and the Jinjiram submerged more than 200 villages of the Garo plains in the same spell of rain that set off the slides of the Garo Hills (as reported). The reservoirs of MePGCL release water by siren and SMS warning rather than notice (MePGCL), so a release reach can rise while a local storm is falling on the town beside it. These levels give no warning of a local storm that falls while they are high. The levels quoted by different sources differ, and none states its datum: the CWC highest levels are transcribed by SANDRP, not read in a CWC bulletin, and Umiam's full level is known only as "3,220 ft" in the press, beside a spillway crest of 969.5 m in another source (as reported), which is why Chapter 5 requires every level to name its source and datum. Because rainfall and surge share a weather cause (in Meghalaya, which has no coast, the counterpart of surge is the stage of the streams, rivers and reservoirs that receive the town drains, raised by the same monsoon storms that bring the heaviest rain to the towns: on 17 June 2022, when Mawsynram recorded 1,003.6 mm in 24 hours (IMD), 13 people died in the Khasi and Garo Hills and landslides cut NH-6, and in June 2026 the Umngot at Dawki rose rapidly while the Shillong–Dawki road collapsed at Laitlyngkot (as reported)), they cannot be treated as independent. Case (b) is a simple joint-probability surrogate until a statistical joint analysis is adopted.


2.13 Submittal requirements

Every hydrologic submittal shall include a Design Rainfall Sheet (Form 2-1) stating:

  1. the site coordinates and zone;
  2. the source (Clause 2.3), version or access date, and a screenshot or export of the values extracted;
  3. a depth table for each AEP and duration used, before and after the fixed-interval factor, grid-to-point factor, ARF and climate factor;
  4. the cross-check values of Clause 2.3.3 and the floor check;
  5. the hyetographs used, as a table and a plot, for each design storm; and
  6. the AMC and pre-development definition adopted.

Figure 2.3 shows the steps of this chapter in the order in which the sheet records them.

Figure 2.3 — From design rainfall source to design storm Seven steps in sequence: choose the approved source; set AEPs and durations; point depth for each AEP and duration; grid to point and areal reduction; climate factor; temporal pattern; design storm. A side panel lists what Form 2-1 records, and a second panel shows that the retention depth takes a separate route without the climate factor. From design rainfall source to design storm Steps a designer follows in Chapter 2, with the governing clause (schematic flowchart) 1 Choose the approved source Cl. 2.3 NIH-DHAARA at the site coordinates. Station IDF only with ≥ 30 yr record within 10 km; the greater value governs. Report the IMD (Das et al. 2022) cross-check; CWC subzone value is a floor for 25–5,000 km². 2 Set the AEPs and durations Cl. 2.4–2.5 AEP for each element from Table 2.1. Conveyance: duration = Tc, not less than 10 min. Storage: every duration in {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48, 72 h always. 3 Point depth for each AEP and duration Cl. 2.6 Read the depth from the source for each duration. If only daily depths exist, use the Annex 2B ratios (not the one-third rule). Fixed-interval data × 1.13 / 1.04 / 1.02 for 1 / 2 / 3–4 intervals. 4 Grid to point, then areal reduction Cl. 2.7 Grid-average values × grid-to-point factor (Annex 2C). ARF = 1.0 up to 10 km²; CWC curves above 25 km², linear between. No ARF for storage on a single development site. 5 Apply the climate factor Cl. 2.8 × 1.20 for durations ≤ 6 h; × 1.10 for > 6 h to 72 h. CF = 1.0 for temporary works (design life ≤ 5 years). Not applied to the retention depth or the WQv depth. 6 Build the temporal pattern Cl. 2.9 ≤ 24 h: alternating block, peak at 50%, time step ≤ Tc/3 and ≤ 15 min. 48 / 72 h: the 24 h design depth in the final 24 h; the remainder spread uniformly before it. SCS Type I, IA, II and III are not permitted. 7 Design storm (hyetograph) Cl. 2.11–2.12 Same storms for pre- and post-development runs. AMC II for storms ≤ 6 h; AMC III for 12 h and longer. Tidal or backwater outfalls: also run the joint cases of Clause 2.12. Form 2-1 Design Rainfall Sheet (Cl. 2.13) records: 1. Site coordinates and zone 2. Source, version or access date, export 3. Depth table before and after each factor (steps 3–5) 4. Cross-checks and the CWC floor 5. Hyetographs: table and plot (steps 6–7) 6. AMC and pre- development condition Retention depth (separate route) 90th percentile wet-day (≥ 2.5 mm) 24 h depth, zone value from Annex 2E. No climate factor, no hyetograph for sizing the volume. Cl. 2.10, 2.8.3 Schematic flowchart. Clause numbers refer to Chapter 2. The order of steps 3–5 is the order of the columns of the depth table on Form 2-1.

Figure 2.3 — From design rainfall source to design storm: the steps a designer follows (source, AEPs and durations, point depth, grid-to-point and areal reduction, climate factor, temporal pattern, design storm), the clause that governs each step, what Form 2-1 records, and the separate route for the retention depth. Schematic. Original drawing for this Manual.


2.14 Review and update

2.14.1 The approving authority shall review this chapter every 10 years. It shall also review it within 2 years of any event in which recorded rainfall exceeds the 1% AEP 24-hour or 72-hour design depth at two or more approved gauges in the State.

2.14.2 Updates to NIH-DHAARA take effect for new submittals 6 months after release, unless the authority notifies otherwise.


References (chapter)

  • National Institute of Hydrology, Roorkee. NIH-DHAARA: Design Hydrology and Advanced Rainfall Analysis. http://www.nihdhaara.in/
  • Das, S.K. et al. (2022). Isopluvial analysis and intensity–duration–frequency curves for different cities in India. MAUSAM 73(4), 887–898. https://metnet.imd.gov.in/docs/mausamdocs/173412_F.pdf
  • Central Water Commission (2000). Flood Estimation Report for South Brahmaputra Subzone 2(b) (Revised), Design Office Report No. SB-2(b)/R-4/44/99, March 2000, approved by the Flood Estimation Planning and Co-ordination Committee at its 55th meeting on 13.3.2000; revises SB/8/1984; prepared jointly with IMD, RDSO and the Ministry of Surface Transport (Plates 8, 9 and 10, the 25-, 50- and 100-year maps, read by eye from page images; p. 18, extent and boundaries; Table 3.3, the unit hydrograph; Table 4.1, the short-duration ratios; Annexes 3.1 and 3.2, the bridge catchments; Annexes 4.1 and 4.2, the heaviest daily falls and recording-gauge maxima; the list of reports published by 2000, pp. 6–7; Wayback Machine capture of 12 Apr 2016 of the cwc.gov.in copy). https://cwc.gov.in/regional-flood-estimation-report
  • Central Water Commission (1991). Flood Estimation Report for North Brahmaputra Subzone 2(a), Design Office Report No. NB/18/1991, Hydrology (Small Catchments) Directorate (§3.1.2, p. 24, and Fig. 10, the short-duration ratios, used in sub-areas ML-B, ML-B1 and ML-D under Clause 2.3.6(f); no part of Meghalaya lies in 2(a)). https://cwc.gov.in/regional-flood-estimation-report
  • Central Water Commission. Regional Flood Estimation Reports page (Wayback Machine capture of 20 Mar 2024; no report for subzone 2(c), Barak). http://web.archive.org/web/20240320001002/https://cwc.gov.in/regional-flood-estimation-report
  • MoHUA / CPHEEO (2019). Manual on Storm Water Drainage Systems, Part A.
  • India Meteorological Department. Extremes of Temperature and Rainfall for Indian Stations (up to 2012): Cherrapunji (42515, rainfall data 1902–2012) and Shillong (C.S.O.) (42516, rainfall data 1957–2012), monthly and seasonal extremes. https://imdpune.gov.in/library/public/EXTREMES%20OF%20TEMPERATURE%20and%20RAINFALL%20upto%202012.pdf
  • India Meteorological Department. Monthly Climate Summary, June 2022. https://imdpune.gov.in/cmpg/Product/Monthly_Climate_Summary/Monthly_Clim_Summary_6_2022.pdf
  • India Meteorological Department, Meteorological Centre Shillong. Daily realised rainfall map (gauge names; seen 12 Nov 2026). https://mausam.imd.gov.in/shillong/mcdata/Rainfall.pdf
  • India Meteorological Department. Climatological summary of Meghalaya, district tables of heaviest rainfall, revised normal dates of onset and withdrawal for Shillong, and hourly maxima for Cherrapunji and Mawsynram (not obtained [TBC]).
  • Das, S.K., Srivastava, A.K. & Yadav, B.P. (IMD) (2022). MAUSAM 73(4), 887–898, Fig. 4(v) (Cherrapunji) and Fig. 4(xxv) (Shillong), pp. 894–896. https://metnet.imd.gov.in/docs/mausamdocs/173412_F.pdf
  • NIH-DHAARA, IDF tool, IMDAA dataset, queried for ten points in Meghalaya on 14 Nov 2026 (tool output). http://117.252.14.251:8080/
  • Integrated Research and Action for Development (2020). Disaster Resilience Action Plan, Shillong, IRADe-PR-73(2020), for the National Mission on Himalayan Studies (RMSI's method of 2019; the State Action Plan on Climate Change of 2015 as quoted; Table 17, flood events).
  • Ram Babu, Dhyani, B.L. & Nirmal Kumar (2006). Rainfall intensity–duration–return period equations for the zones of India (poster, 14th ISCO Conference; CSWCRTI, now ICAR-IISWC; not used).
  • Central Ground Water Board, North Eastern Region, Guwahati (2022). Dynamic Ground Water Resources of Meghalaya (GWRA 2022). http://web.archive.org/web/20250402124501/https://www.cgwb.gov.in/old_website/GW-Assessment/GWR-2022-Reports%20State/Meghalaya.pdf
  • Meghalaya Power Generation Corporation Ltd. Guidelines for the operation of the gates of Umiam–Umtru Stage III (2026), Stage IV (2025), New Umtru (2025) and Myntdu–Leshka Stage I (4 April 2022). https://meecl.nic.in/
  • Government of Meghalaya. Meghalaya State Action Plan on Climate Change (2015) and version 2.0 (2023–2030) (not read; quoted in the IRADe/NMHS plan and summarised in the State's budget note on climate action, 2025-26 [TBC]).
  • Study of extreme daily precipitation at Imphal and Shillong, 1985–2003 (Indian Journal of Hill Farming 32(1); seen as a summary only [TBC]). https://kiran.nic.in/pdf/IJHF/Vol_32_1/26.pdf
  • South Asia Network on Dams, Rivers and People (2018). Overview of CWC's flood monitoring and forecasting in North East India (transcriptions of CWC data; secondary source). https://sandrp.in/2018/08/05/overview-of-cwcs-flood-monitoring-forecasting-in-north-east-india/
  • Press reports of the storms of June 1995 and June 2022, the WMO 48-hour record, the monsoon onset and withdrawal of 2025 and 2026 and the monsoon of 2026 (secondary sources).
  • Chow, V.T., Maidment, D.R. & Mays, L.W. (1988). Applied Hydrology. McGraw-Hill (alternating-block method, §14.4).
  • Kansas City Metro Chapter APWA (2025). Section 5600 Storm Drainage Systems and Facilities, Version 2025.01.
  • Mile High Flood District (Denver). Urban Storm Drainage Criteria Manual (90% release rationale).
  • Department of Irrigation and Drainage Malaysia (2008, 2012). Urban Stormwater Management Manual (MSMA).

Annexes

Annex Content
2A NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map
2B Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule
2C Grid-to-point factors
2D Meghalaya temporal patterns (Huff curves)
2E Retention percentile depths by zone
Form 2-1 Design Rainfall Sheet