Draft v1.0 prepared by NEER. Not adopted by the Government of Punjab or the Chandigarh Administration, and has no legal force. About this draft

Annexes to Chapter 2Design Rainfall and Design Storms

These annexes support Chapter 2. Annexes 2A to 2E will hold the statewide rainfall tables that Chapter 2 refers to: the benchmark checks and zone map, sub-daily ratios, grid-to-point factors, temporal patterns and retention depths. Each needs analysis of NIH-DHAARA and IMD records that has not yet been done for this Manual, so each is marked "To be prepared" and gives its intended layout and the rule to use until it is published (Clause 1.11.5). Form 2-1 is a draft form for the Design Rainfall Sheet that every hydrologic submittal must include (Clause 2.13). The Manual is a draft; it is not adopted by any government or agency.


Annex 2A — NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map

Supports Clauses 2.3.1 to 2.3.5 of Chapter 2.

To be prepared. This annex will compare, at benchmark points across the State, the NIH-DHAARA design depths with frequency analyses of long IMD daily station records and of IMD gridded daily data (converted to point values with Annex 2C), for 24 hours and longer and for the AEPs of Table 2.1. It will also contain the map of rainfall zones used by Annexes 2B, 2C and 2E and by the Tier B tables of Chapter 4. It needs NIH-DHAARA values at the benchmark coordinates (NIH), IMD daily and recording-gauge station records and IMD gridded rainfall (IMD), State rain-gauge records (the tehsil rain gauges whose readings the district administrations and the Department of Revenue, Rehabilitation and Disaster Management report, the gauges of WRD and BBMB, the agrometeorological observatories of PAU at Ludhiana, Ballowal Saunkhri and Bathinda, and any automatic gauges of the Municipal Corporations and the Smart City command centres [TBC]), and district and basin boundaries (Survey of India, WRD). Until it is published, design depths are taken from NIH-DHAARA under Clause 2.3.1, the cross-checks of Clause 2.3.3 are reported on Form 2-1, and the zone of a site is the one agreed with the Authority and recorded on Form 2-1.

Table 2A.1 — Benchmark comparison of design depths (layout)

Benchmark point IMD station ID Latitude, longitude Years of record Duration (h) AEP NIH-DHAARA (mm) IMD station analysis (mm) IMD gridded, point value (mm) NIH-DHAARA / IMD station Remarks
        24            
        48            
        72            

2A.1 The zone names below are the working names used in the Tier B table template of Chapter 4 (Clause 4.14.2). Their boundaries, and whether further zones are needed, are to be set by the analysis of this annex.

Table 2A.2 — Rainfall zones (layout)

Zone (working name) Extent (districts, basins) Representative stations Notes
PB-Z1 Shivalik–Kandi The Shivalik hills and the Kandi piedmont below them, from Pathankot and Dhar Kalan through Talwara, Mukerian–Dasuya, Hoshiarpur and Garhshankar to Nangal, Anandpur Sahib, Rupnagar and the Kharar–Mullanpur hills: CWC zone 7 in the hills and on the Shivalik fringe beyond the line, subzone 1(e) on the piedmont, and both at Rupnagar, on the line (Clause 2.3.6(b)); catchments that cross a report or zone line take the higher value Pathankot Aero (no IMD station with 30 years found [TBC]); the zone-7 recording gauges at Madhopur and Hoshiarpur; Chandigarh 42105 (1954–2009) for the Kharar hills District annual normals 801.4 mm in Rupnagar, 818.8 mm in Hoshiarpur and 1,106.1 mm in Gurdaspur, the highest in the State (IMD, 1901–1980). Zone-7 Plate 9 about 320 mm at Pathankot and 280 mm at Nangal and Anandpur Sahib; 1(e) spot of 263 mm at Hoshiarpur and about 240–260 mm at Rupnagar (50-yr); 1-h ratio 0.425 (zone 7) or 0.34 (1(e)). NIH-DHAARA 50-yr 24-h high here (Pathankot 443, Nangal 307, Rupnagar 302, Hoshiarpur 300 mm)
PB-Z1 Shivalik–Kandi: PB-A Shivalik foothills and Kandi (Pathankot–Talwara–Hoshiarpur–Garhshankar–Nangal–Anandpur Sahib–Rupnagar–Mullanpur) Also Dhar Kalan, Sujanpur, the Mukerian–Dasuya hills, Balachaur, Kurali, New Chandigarh, the Siswan and the Kharar hills; boundaries [TBC] Pathankot Aero, Madhopur, Hoshiarpur, Garhshankar, Rupnagar (rain gauges of Climate of Punjab) The Kandi belt, 10–15 km wide below the hills, of deposits grading "from boulders to clays", explored to 450 m, with a slope of about 16 m/km decreasing westwards, and the Sirowal seepage belt at its toe (CGWB); "more than 100 choes" in Hoshiarpur district leaving "thick deposits of sand and silt" (Hoshiarpur District Environment Plan); deep water tables on the fans (stage of extraction 53% in Pathankot, 100% in Ropar, 102% in Hoshiarpur district, 2020). Records: Garhshankar 470.0 mm (31 Jul 1976), Pathankot Aero 355.0 mm (14 Jul 1980), Madhopur 351.0 mm (5 Oct 1955), Rupnagar 310.4 mm (30 Jul 1951) (IMD); Ropar 35 cm in the 24 hours to 08:30 on 10 Jul 2023 and Nangal 28 cm to 9 Jul 2023 (IMD press releases); recording-gauge maxima Madhopur 100 mm in 1 h (16 Sep 1975) and 329 mm in 24 h (23–24 Jul 1974), Hoshiarpur 81 mm in 1 h (5 Aug 1982) (CWC, zone 7). Receiving waters: the Chakki Khad at Pathankot (657.86 km², a zone-7 unit-hydrograph catchment); the Ravi at Madhopur and Shahpur Kandi; the Beas below Pong at Talwara; the Sutlej at Nangal and Ropar below Bhakra (Ropar 2.4 lakh cusecs in 1988 and 1.79 lakh in Jul 2023, as reported); the Swan to the Sutlej near Anandpur Sahib; the Kandi choes, with 12 low dams and WRD's 410 check dams on rivers and nallahs
PB-Z2 Northern and central plains The wetter plains of Majha and Doaba north of the "240 arm" of the plates, and the central belt from the Sutlej at Ludhiana to the Ghaggar at Patiala and SAS Nagar, in CWC subzone 1(e); catchments that cross a zone line take the higher zone value Ludhiana(A) 42099 (1901–2012), Patiala 42101 (1901–2012), Kapurthala 42074 (1972–2012), Ludhiana PAU 06203 (1966–2011), Chandigarh 42105 (1954–2009) for SAS Nagar District annual normals 648.1 mm in Patiala, 660.3 mm in Ludhiana, 703.0 mm in Jullundur, 778.9 mm in Kapurthala (IMD, 1901–1980). FER 1(e) 50-yr 24-h about 240–262 mm and 100-yr about 240–292 mm; 1-h ratio 0.34. The storm of 4–5 October 1955 put more than 330 mm in a day on several gauges at once. NIH-DHAARA 50-yr 24-h 211–341 mm
PB-Z2 Northern and central plains: PB-B Majha–Doaba north (Gurdaspur–Batala–Jalandhar–Kapurthala–Phagwara–Nawanshahr) Also Dera Baba Nanak, Dinanagar and the Mukerian plains; boundaries [TBC] Kapurthala 42074; Gurdaspur, Batala and Tibri (rain gauges of Climate of Punjab) Recent alluvium of the Ravi, Beas and Sutlej; stage of extraction 257% in Jalandhar and 220% in Kapurthala district (2020), with water levels falling more than 0.5 m a year in Jalandhar; 1.5–5 m pockets in Gurdaspur. FER 1(e) 50-yr 24-h about 240–260 mm at Gurdaspur, Batala and Kapurthala, and about 200 mm at Jalandhar, inside a closed loop (Clause 2.3.6(c); low confidence). Records: Aliwal 495.3 mm, Batala 474.5 mm and Gurdaspur 370.3 mm (5 Oct 1955), Tibri 385.6 mm (4 Sep 1950), Kapurthala 284.2 mm (24 Sep 1988) (IMD). Receiving waters: the Ravi and its dhussi bandh (breaches in the Ajnala–Ramdass area in 2025, as reported); the Beas from Mukerian to Harike; the Kali Bein, the Chitti Bein and the Kala Sanghian drain; the Sakki/Kiran nallah; the Sutlej at Phillaur and Shahkot (breaches of 19–20 Aug 2019, as reported)
PB-Z2 Northern and central plains: PB-C Central Sutlej–Ghaggar belt (Ludhiana–Khanna–SAS Nagar–Zirakpur–Rajpura–Patiala–Fatehgarh Sahib) Also Samrala, Jagraon, Kharar, Dera Bassi, Nabha and Sirhind; boundaries [TBC] Ludhiana(A) 42099, Ludhiana PAU 06203, Patiala 42101, Chandigarh 42105; Jagraon (rain gauge of Climate of Punjab); the Patiala recording gauge of the zone-7 report Older alluvium, sandy loam to loam; stage of extraction 211% in Ludhiana, 226% in Patiala and 202% in Fatehgarh Sahib district (2020), with a fall of 36.15 m at Rajpura in 1984–2019 (CGWB). FER 1(e) 50-yr 24-h about 240–262 mm in a central cell bounded by the 240 mm line, with spots of 262 and 289 mm at Chandigarh; the short-storm floors of Clause 2.3.6(g)(ii) apply. Records: Jagraon 433.6 mm (18 Sep 1950), Patiala 356.5 mm (11 Jul 1993), Ludhiana 354.3 mm (4 Oct 1955), Ludhiana PAU 338.0 mm (24 Sep 1988), Chandigarh 302.2 mm (9 Jul 2023), Rajpura 26 cm (to 08:30 on 10 Jul 2023) (IMD); Patiala recording gauge 93 mm in 1 h and 153 mm in 3 h (21 Jul 1982) (CWC, zone 7). Receiving waters: the Buddha Nallah to the Sutlej at Walipur Kalan (2-yr channel design; PMIDC); the Sutlej at Ludhiana; the Ghaggar at Bhankharpur and Sarala Kalan, with the Patiali-ki-Rao, the Jayanti Devi ki Rao, the N-Choe and the Sukhna Choe from the Shivaliks and Chandigarh; the Badi and Chhoti Nadi at Patiala; the Sirhind choe under the Bhakra Main Line by siphon; the SYL and Narwana branch crossings at Rajpura
PB-Z3 Western and Malwa plains The plains of Majha west of the "240 arm" to the border and of central Malwa, in CWC subzone 1(e); catchments that cross a zone line take the higher zone value Amritsar(A) 42071 (1948–2011), Ferozepore 42096 (1950–2012); no IMD station with 30 years found for Sangrur, Moga or Mansa [TBC] District annual normals 388.6 mm in Ferozpur, 557.6 mm in Sangrur and 598.7 mm in Amritsar (IMD, 1901–1980). FER 1(e) 50-yr 24-h about 200–240 mm and 100-yr about 200–240 mm; 1-h ratio 0.34. NIH-DHAARA 50-yr 24-h 146–215 mm, below the plates at Firozpur and Moga
PB-Z3 Western and Malwa plains: PB-D Majha west and the border (Amritsar–Tarn Taran–Patti–Ferozepur–Zira) Also Ajnala and Khemkaran; boundaries [TBC] Amritsar(A) 42071, Ferozepore 42096; Khara, Raya, Zira and Ferozpur Sadar (rain gauges of Climate of Punjab) Stage of extraction 167% in Amritsar, 193% in Tarn Taran and 133% in Ferozpur district (2020). FER 1(e) 50-yr 24-h about 220 mm (200–240 mm) at Amritsar, Tarn Taran and Ferozepur. Records: Khara 457.2 mm and Raya 367.0 mm (5 Oct 1955), Amritsar 308.4 mm (22 Sep 1962), Zira 301.7 mm (17 Sep 1950), Ferozpur Sadar 282.7 mm (18 Aug 1964), Ferozepore 240.0 mm (1 Aug 1976) (IMD). Receiving waters: the Tung Dhab and City Outfall drains of Amritsar to the Hudiara drain, which enters Pakistan near Lalo; the Kasur and Patti nallahs; the Ravi at Ajnala; the Sutlej at Harike (3,35,030 cusecs on 3 Sep 2025, above the 3-lakh "High Flood" band) and Hussainiwala (3,02,508 cusecs), as reported, with the Sutlej floodplain zone of Ferozepur and Tarn Taran notified on 4 Mar 2024
PB-Z3 Western and Malwa plains: PB-E Malwa centre (Sangrur–Barnala–Malerkotla–Moga–Mansa) Also Sunam, Dhuri, the north of Mansa district and the east of Bathinda district; boundaries [TBC] Patiala 42101 and Ludhiana(A) 42099 (nearest with 30 years); Moga, Bandhar and Bharala (rain gauges of Climate of Punjab) Old alluvium with kankar and sodic patches; the most over-drawn districts, stage of extraction 301% in Sangrur (342% in Dirba block), 250% in Moga and 211% in Barnala (2020), with water tables deeper than 30 m. FER 1(e) 50-yr 24-h about 220–240 mm at Sangrur and Sunam and 200–240 mm at Moga (low confidence). Records: Moga 335.0 mm (5 Oct 1955), Bharala 275.6 mm and Bandhar 266.7 mm (26 Sep 1945) (IMD); Jawahrke 377.2 mm and Mansa 332.7 mm (4 Oct 1955) from gauges of fewer than 20 years, excluded by Clause 2.3.6(h). Receiving waters: the Ghaggar at Khanauri (753–754.2 ft on 13–15 Jul 2023 against a danger mark reported as 748 ft), Moonak and Makraud Sahib, with breaches in 1993, 2010 and 2023 (as reported); the Sunam choe
PB-Z4 South-west The dry south-west, with dune sands, waterlogged depressions and saline groundwater, in CWC subzone 1(e) near its line with subzone 1(a); catchments that cross a zone line take the higher zone value Bhatinda 42097 (1959–1982) as a check only; no IMD station with 30 years found [TBC] District annual normals 388.6 mm in Ferozpur, 429.8 mm in Bhatinda and 433.0 mm in Faridkot (IMD, 1901–1980), the lowest in the State. FER 1(e) 50-yr 24-h 160 mm at Bathinda and Abohar (a closed cell, Clause 2.3.6(c)) to about 180 mm; 1-h ratio 0.34. NIH-DHAARA 50-yr 24-h low here (Abohar 104, Fazilka 116, Sri Muktsar Sahib 116, Mansa 123, Bathinda 126 mm)
PB-Z4 South-west: PB-F South-west sands, waterlogging and salinity (Bathinda–Sri Muktsar Sahib–Malout–Fazilka–Abohar–Faridkot) Also Gidderbaha, Kotkapura and Sardulgarh in the south of Mansa district; boundaries [TBC] Bhatinda 42097 (check only); Bhatinda, Fazilka and Abohar (rain gauges of Climate of Punjab) Dune sands to sandy loam, with final infiltration rates of 0.05–0.26 cm/min measured on dry cultivated soils (PAU, 1995); the water table within 3 m over the waterlogged parts of Sri Muktsar Sahib, Fazilka and Faridkot (0.53 m at Kot Bhai in October 2019) and saline groundwater, with an EC of up to 8,320 µS/cm at Abohar (CGWB). FER 1(e) 50-yr 24-h about 160–180 mm. Records: Bhatinda rain gauge 256.1 mm (18 Aug 1964), Fazilka 182.9 mm (31 Aug 1908), Faridkot 182.0 mm (18 Aug 1964), Abohar 175.8 mm (2 Sep 1958) (IMD). Receiving waters: seasonal drains with little fall to the Sutlej at Hussainiwala; the Rajasthan and Sirhind feeders, which block cross-drainage and whose seepage feeds the waterlogging (as reported); pumped drainage and RCC pipelines from low villages (WRD); the Ghaggar at Sardulgarh

Annex 2B — Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule

Supports Clauses 2.6.1 to 2.6.4 of Chapter 2.

To be prepared. This annex will tabulate, for each zone of Annex 2A, the ratios of the t-hour to the 24-hour design depth from NIH-DHAARA, which are derived from hourly records, against the ratios implied by IMD Das et al. (2022) and by the one-third rule. It needs NIH-DHAARA depths for each duration at representative points in each zone (NIH), IMD recording-gauge data and the IDF values of Das et al. (2022) (IMD). Until it is published, sub-daily depths are read directly from NIH-DHAARA or an approved station IDF (Clause 2.6.1). Where only daily depths are available, the ratios used are those agreed with the Authority, which in Punjab are those of Clause 2.3.6: the CWC Flood Estimation Report ratios in Table 2B.1 for the report that covers the site (subzone 1(e) in the plains and the Kandi piedmont; zone 7 in the zone-7 part of sub-area PB-A; both at Rupnagar, the higher governing), raised at 1 and 3 hours to the floors of Clause 2.3.6(g) for the 10-yr and rarer storms, and applied to the 24-hour depth before the record check of Clause 2.3.6(h) (Clause 2.6.2), and are recorded on Form 2-1. The one-third rule is not used (Clause 2.6.4).

2B.1 The first row of Table 2B.1 gives the ratios of the one-third rule P(t) = P(24)·(t/24)^(1/3), for comparison only. The 1, 3, 6 and 12 h values are those stated in the commentary to Clause 2.6; the 2 h value is computed from the same formula. The rule shall not be used for design unless this annex confirms it for the zone concerned (Clause 2.6.4).

Table 2B.1 — Ratios P(t)/P(24h) by zone (layout)

Zone Source 1 h 2 h 3 h 6 h 12 h 24 h
All (reference only, not for design) One-third rule 0.35 0.44 0.50 0.63 0.79 1.00
PB-Z1 (the 1(e) part of PB-A, the Kandi piedmont), PB-Z2, PB-Z3 and PB-Z4 (all sub-areas) CWC FER 1(e), 50-yr (interim design ratios, Clause 2.3.6(f)) 0.340 0.475 0.560 0.680 0.840 1.00
PB-Z1 (the zone-7 part of PB-A: Pathankot, Dhar Kalan, Sujanpur, Talwara, Nangal, Anandpur Sahib and the Shivalik hills) CWC FER zone 7, 10-yr partial-duration basis (interim design ratios, Clause 2.3.6(f); 2-h value interpolated on logarithmic axes; at Rupnagar both sets, the higher depth governing) 0.425   0.600 0.725 0.845 1.00
All sub-areas, 10–100 yr Ratio floor of Clause 2.3.6(g)(i) 0.35   0.57     1.00
PB-Z1 (zone-7 part of PB-A), every AEP 1-hour floor where a station IDF governs, Clause 2.3.6(f), set by this Manual 0.34          
PB-Z2 (PB-C) Floors of Clause 2.3.6(g)(ii) at 50-yr, 93 mm and 153 mm, as ratios to the 240–262 mm of the plates in PB-C (comparison only; the floors are depths) 0.35–0.39   0.58–0.64     1.00
PB-Z2 (PB-C): Patiala CWC FER zone 7, Annex 4.4: recording-gauge maxima as ratios to the 24-h maximum of the same record (separate storms: 1 and 6 h on 21 Jul 1982, 24 h on 21–22 Jul 1979; date of the 3-h maximum not read [TBC]; comparison only) 0.44   0.73 0.86 1.00 1.00
PB-Z1 (PB-A): Madhopur CWC FER zone 7, Annex 4.4: recording-gauge maxima (separate storms: 1 h on 16 Sep 1975, 3 to 24 h on 23–24 Jul 1974; comparison only) 0.30   0.66 0.87 1.00 1.00
PB-Z1 (PB-A): Hoshiarpur CWC FER zone 7, Annex 4.4: recording-gauge maxima of 4–5 Aug 1982, one compact storm (comparison only) 0.59   0.96 1.00 1.00 1.00
PB-Z2 (PB-C): Ludhiana NIH-DHAARA, 50-yr, Ludhiana cell (comparison only; 3- and 6-hour values not queried) 0.33 0.48     0.83 1.00
PB-Z2 (PB-C): Mohali NIH-DHAARA, 50-yr, Mohali cell (comparison only; 3- and 6-hour values not queried) 0.25 0.38     0.83 1.00
PB-Z1 (PB-A): Pathankot NIH-DHAARA, 50-yr, Pathankot cell (comparison only; 3- and 6-hour values not queried) 0.24 0.38     0.83 1.00
PB-Z4 (PB-F): Bathinda NIH-DHAARA, 50-yr, Bathinda cell (comparison only; 2-, 3- and 6-hour values not queried) 0.35       0.85 1.00

2B.2 Depths from fixed observation windows are converted to true-interval depths with the factors of Clause 2.6.3, repeated in Table 2B.2. They are the standard WMO (Hershfield) values and are not provisional.

Table 2B.2 — Fixed-interval adjustment factors (Clause 2.6.3)

Number of fixed observation intervals in the duration Factor
1 1.13
2 1.04
3–4 1.02

Annex 2C — Grid-to-point factors

Supports Clauses 2.7.1 and 2.7.4 of Chapter 2.

To be prepared. This annex will give the factors that convert grid-average design depths (for example from 0.25° cells) to point depths, by zone, duration and AEP. It needs paired frequency analyses of IMD gridded rainfall and of the IMD and State gauges inside each cell (IMD, WRD, PAU and the tehsil rain gauges whose readings the State reports [TBC]), the benchmark points of Annex 2A, and a stated method for deriving the factors. Until it is published, design depths are taken as point values from NIH-DHAARA or an approved station IDF (Clauses 2.3.1 and 2.3.2). Grid-average values are not used as design depths unless a conversion agreed with the Authority is recorded on Form 2-1 (Clause 1.11.5).

2C.1 The commentary to Clause 2.7 shows why the factors matter, and in Punjab the reanalysis cells err in both directions, more widely than in any other State of the series. In the south-west they err low: the IMDAA cell of NIH-DHAARA (about 12 km) at Bathinda gives a 50-year 24-hour depth of about 126 mm and a 100-year depth of about 141 mm, against a CWC plate value of 160 mm and the 256.1 mm recorded by the Bhatinda rain gauge on 18 August 1964; at Mansa about 123 mm; at Firozpur about 146 mm, against about 220 mm on the plate and the 301.7 mm recorded at Zira on 17 September 1950; and at Abohar, Fazilka and Sri Muktsar Sahib about 104–116 mm, against plate values of about 160–180 mm. In the centre the cell at Ludhiana gives about 211 mm, against the 354.3 mm of the Ludhiana observatory (4 October 1955). On the Shivalik front they err high: about 443 mm at Pathankot, against about 320 mm on the zone-7 plate, 341 mm at Gurdaspur and 300–307 mm at Hoshiarpur, Rupnagar and Nangal, against about 240–263 mm on the 1(e) plates. The cells' 50-year 1-hour depths, about 39–105 mm, are 0.24–0.39 of their 24-hour depths (NIH-DHAARA, queried 13 Nov 2026; IMD; CWC). Values of this kind are grid-average values and need these factors before any use as point depths; under Clause 2.3.6 they are not used as design depths in Punjab until this annex and Annex 2A are published.

Table 2C.1 — Grid-to-point factors (layout)

Zone Grid product and cell size Duration (h) AEP Factor (point / grid) Stations used Years of record
    24        
    48        
    72        

Annex 2D — Punjab temporal patterns (Huff curves)

Supports Clauses 2.9.3 and 2.9.4 of Chapter 2, and Clause 11.7.3 of Chapter 11.

To be prepared. This annex will give dimensionless time-distribution (mass) curves of Punjab storms, in the form introduced by Huff (1967), by zone, storm-duration class and quartile, at stated probability levels. It needs storm hyetographs from recording gauges and automatic weather stations (IMD, its automatic weather stations and automatic rain gauges in the State, among them Balachaur, Ropar KVK, Fatehgarh Sahib and Adampur, under the Meteorological Centre Chandigarh; the recording gauges of PAU; and any recording gauges of WRD, BBMB and the city command centres [TBC]), separated into independent storms by a stated rule, and the storms of 4–5 October 1955 across Majha, Doaba and central Malwa, 24 September 1988 at Ludhiana and Kapurthala, 11 July 1993 at Patiala, 5 September 1995 at Ludhiana and 8–10 July 2023 at Ropar, Nangal, Balachaur, Rajpura and Chandigarh, and the falls of August–September 2025 over the Ravi, Beas and Ghaggar catchments and in Mohali, Ludhiana, Jalandhar and Amritsar among them. Until it is published, design storms use the alternating-block pattern of Clause 2.9.1 and the 48- and 72-hour pattern of Clause 2.9.2; for catchments of 25–5,000 km², the CWC Flood Estimation Report curves may be used with a sensitivity run under Clause 2.9.1 (Clause 2.9.4). SCS Type distributions are not used (Clause 2.9.3). For the disaggregation of daily records in continuous simulation (Clause 11.7.3), the method is agreed with the Authority and recorded (Clause 1.11.5).

Table 2D.1 — Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)

Fraction of storm time 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
10% probability curve 0                   1.0
50% probability curve 0                   1.0
90% probability curve 0                   1.0

2D.1 Each table shall state the zone, the duration class, the quartile (the quarter of the storm in which most rain fell), the number of storms analysed and the period of record.

Reference: Huff, F.A. (1967). Time distribution of rainfall in heavy storms. Water Resources Research 3(4), 1007–1019.


Annex 2E — Retention percentile depths by zone

Supports Clauses 2.8.3 and 2.10.1 to 2.10.2 of Chapter 2, Clause 4.4 of Chapter 4 and Chapter 8.

To be prepared. This annex will give, for each zone of Annex 2A, the retention design depth P_R: the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record (Clause 2.10.1). It needs long daily records at stations in each zone (IMD, WRD, PAU and the tehsil rain gauges whose readings the State reports [TBC]) and IMD gridded data with the factors of Annex 2C where stations are sparse. Until it is published, P_R is computed by the definition of Clause 2.10.1 from the long-term daily record of a station agreed with the Authority, by the steps in 2E.1, and recorded on Form 2-1 (Clause 1.11.5).

2E.1 Computing P_R from a daily record.

  1. Take the daily (24-hour) rainfall series of the station for its full record.
  2. Keep only the days with rain of 2.5 mm or more (wet days).
  3. Rank the wet-day depths and take the depth not exceeded on 90% of them (the 90th percentile).
  4. Do not apply the climate factor (Clause 2.8.3) or the fixed-interval factor; P_R is a statistic of everyday rainfall, not an AEP design depth.
  5. Record the station, the period of record, the number of wet days and P_R on Form 2-1.

Table 2E.1 — Retention depth P_R by zone (layout)

Zone Stations or grid cells used Period of record Number of wet days (≥ 2.5 mm) P_R, 90th percentile (mm) Issued on
PB-Z1 Shivalik–Kandi          
PB-Z2 Northern and central plains          
PB-Z3 Western and Malwa plains          
PB-Z4 South-west          

Form 2-1 — Design Rainfall Sheet

Supports Clauses 2.3 to 2.13 of Chapter 2, and Clause 10.4.1(d) of Chapter 10.

Draft form — Punjab Stormwater Design Manual, Draft v1.0. One sheet for each hydrologic submittal. The steps follow Figure 2.3 of Chapter 2.

Table 2F.1 — Form 2-1: site, source and storms

No. Item (clause) Entry
A. Site (Clause 2.13, item 1)
A1 Project and site ______
A2 Site coordinates (latitude, longitude, decimal degrees) ______
A3 Rainfall zone (Annex 2A, or as agreed with the Authority) ______
A4 Contributing catchment area (km²) (Clause 2.7) ______
A5 Design life: more than 25 years / temporary works, 5 years or less (Clause 2.8.2) ______
A6 Outfall under tidal or river backwater influence: Yes / No (Clauses 2.5.3, 2.12) ______
B. Source (Clauses 2.3, 2.3.5; item 2)
B1 NIH-DHAARA: version or access date ______
B2 Coordinates queried ______
B3 Screenshot or export of the values extracted attached: reference ______
B4 Station IDF used (Clause 2.3.2): No / Yes — station, ID, distance from site (km) ______
B5 Station IDF: years of recording-gauge data (30 or more); published or approved by ______
B6 Station IDF: change of terrain or coastal exposure between gauge and site: None / describe ______
C. AEPs and durations (Clauses 2.4, 2.5)
C1 Elements designed and their AEPs (Table 2.1) ______
C2 Conveyance: Tc and design duration (not less than 10 min) (Clause 2.5.1) ______
C3 Storage: durations checked from {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48 and 72 h included (Clause 2.5.2) ______
C4 Critical duration found for each storage element ______
D. Conversions
D1 Sub-daily depths: read directly / from Annex 2B ratios / from ratios agreed with the Authority (Clauses 2.6.1, 2.6.2) ______
D2 Fixed-interval factor applied: none (true-interval source) / 1.13 / 1.04 / 1.02 (Clause 2.6.3) ______
D3 Grid-to-point factor: not needed (point source) / Annex 2C / agreed value (Clause 2.7.1) ______
D4 ARF: 1.0 (10 km² or less; single-site storage) / CWC curve / interpolated (Clauses 2.7.2–2.7.4) ______
D5 Climate factor: 1.20 (≤ 6 h) and 1.10 (> 6–72 h) / 1.0 temporary works / projected depths under Clause 2.8.4 ______
E. Cross-checks (Clause 2.3.3; item 4)
E1 IMD Das et al. (2022) values for 1–24 h: reported in Table 2F.2 ______
E2 CWC subzone 1(e) or zone 7 24-hour point value, catchments of 25–5,000 km²: subzone used ______
E3 CWC floor governs for any AEP: No / Yes — AEPs ______
F. Retention depth (Clause 2.10)
F1 P_R (mm) and source: Annex 2E zone value / computed under Annex 2E, 2E.1 — station and period ______
F2 No climate factor applied to P_R (Clause 2.8.3): confirmed ______
G. Design storms (Clauses 2.9, 2.11, 2.12; items 5 and 6)
G1 Storms up to 24 h: alternating block, peak at 50%; time step (≤ Tc/3 and ≤ 15 min) ______
G2 48 and 72 h storms: built under Clause 2.9.2 (Table 2F.3) ______
G3 Other pattern used: none / Annex 2D / CWC FER with sensitivity run (Clauses 2.9.3, 2.9.4) ______
G4 Hyetographs attached as a table and a plot for each design storm: reference ______
G5 AMC: III for every design storm of 15 June–30 September under paddy or other ponded fields in PB-B to PB-F and on the bet lands of the Sutlej, Beas, Ravi and Ghaggar, and of 1 July–31 October in PB-F and the Sirowal belt where the October water table is within 3 m, whatever its duration; at any other site or time, III for a storm that follows or contains a 5-day total of more than 53 mm; II otherwise (Clause 2.11.4) ______
G6 Pre-development condition: greenfield, open land in good condition for the mapped HSG (Clause 2.11.5) ______
G7 Release criterion: standard, Q_post ≤ 0.9 × Q_pre (Clause 2.11.2) / flood-sensitive, mixed-frequency rule (Clause 2.11.3) ______
G8 Tailwater joint cases run (Clause 2.12): case (a) MHWS + sea-level allowance; case (b) 10% AEP 48 h storm with 1% AEP still-water level + sea-level allowance; governing case ______
H. Prepared by
H1 I confirm that the values above are those extracted and used in the submittal. Name, registration number, signature, date ______

Design depth = source depth × fixed-interval factor × grid-to-point factor × ARF × climate factor. Where the design depth is lower than the CWC floor for the same AEP, the floor is adopted (Clause 2.3.3).

Table 2F.2 — Form 2-1: depth table (Clause 2.13, item 3)

AEP (T-yr) Duration Source depth (mm) Fixed-interval factor Grid-to-point factor ARF Climate factor Design depth (mm) IMD Das et al. (2022) (mm) CWC floor (mm) Adopted depth (mm)
                     
                     
                     
                     

Table 2F.3 — Form 2-1: 48- and 72-hour storm construction (Clause 2.9.2)

AEP (T-yr) Duration (h) Total design depth (mm) 24 h design depth, final 24 h (mm) Remainder (mm) Hours before the final 24 h Uniform intensity before the final 24 h (mm/h)
  48       24  
  72       48