Draft v1.0 prepared by NEER. Not adopted by the Government of Sikkim or any authority or local body, and has no legal force. About this draft

Annexes to Chapter 2Design Rainfall and Design Storms

These annexes support Chapter 2. Annexes 2A to 2E will hold the statewide rainfall tables that Chapter 2 refers to: the benchmark checks and zone map, sub-daily ratios, grid-to-point factors, temporal patterns and retention depths. Each needs analysis of NIH-DHAARA and IMD records that has not yet been done for this Manual, so each is marked "To be prepared" and gives its intended layout and the rule to use until it is published (Clause 1.11.5). Form 2-1 is a draft form for the Design Rainfall Sheet that every hydrologic submittal must include (Clause 2.13). The Manual is a draft; it is not adopted by any government or agency.


Annex 2A — NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map

Supports Clauses 2.3.1 to 2.3.5 of Chapter 2.

To be prepared. This annex will compare, at benchmark points across the State, the NIH-DHAARA design depths with frequency analyses of long IMD daily station records and of IMD gridded daily data (converted to point values with Annex 2C), for 24 hours and longer and for the AEPs of Table 2.1. It will also contain the map of rainfall zones used by Annexes 2B, 2C and 2E and by the Tier B tables of Chapter 4. It needs NIH-DHAARA values at the benchmark coordinates (NIH), IMD daily and recording-gauge station records and IMD gridded rainfall (IMD), State rain-gauge records (the district network of the Meteorological Centre Gangtok, among them Namchi, Gyalshing, Pakyong and Soreng, whose types and record lengths are to be confirmed, the ordinary rain gauges at Singhik and Dikchu used by the CWC 2(a) report, the gauges at Mangan and Chungthang, the hydro-meteorological gauges of the hydropower projects (Teesta-V, Dikchu, Chuzachen), the India-WRIS station at Lachen and the gauges of the Water Resources Department [TBC]), and district and basin boundaries (Survey of India, WRD). Until it is published, design depths are taken from NIH-DHAARA under Clause 2.3.1, the cross-checks of Clause 2.3.3 are reported on Form 2-1, and the zone of a site is the one agreed with the Authority and recorded on Form 2-1.

Table 2A.1 — Benchmark comparison of design depths (layout)

Benchmark point IMD station ID Latitude, longitude Years of record Duration (h) AEP NIH-DHAARA (mm) IMD station analysis (mm) IMD gridded, point value (mm) NIH-DHAARA / IMD station Remarks
        24            
        48            
        72            

2A.1 The zone names below are the working names used in the Tier B table template of Chapter 4 (Clause 4.14.2). Their boundaries, and whether further zones are needed, are to be set by the analysis of this annex.

Table 2A.2 — Rainfall zones (layout)

Zone (working name) Extent (districts, basins) Representative stations Notes
SK-Z1 Southern hills and valleys The south of the State, from the Teesta, Rangit and Rongni Chu valley floors to the ridges of about 2,500 m, in CWC subzone 2(a), North Brahmaputra, where Plates 8–10 draw contours (Clause 2.3.6(b)); catchments that cross a zone or sub-area line take the higher value Gangtok (IMD 42299, rainfall 1958–2012) and Tadong (IMD 22209, 1978–2007); the district network of the Meteorological Centre Gangtok (Namchi, Gyalshing, Pakyong, Soreng; types and record lengths [TBC]) FER 2(a) 50-yr 24-h about 240 mm at Gangtok rising to about 360 mm at Jorethang and Melli, in steep west–east bands (NEER reading, low confidence); 2(a) ratios, 1-h ratio 0.260 (Clause 2.3.6(f)); growth factors and 72/24 factor 1.75 (Clause 2.3.6(d), (e)). NIH-DHAARA reported for comparison only (Clause 2.3.6(m)). Thin brown hill soils and colluvium over the phyllites and schists of the Daling Group and the gneisses of the Higher Himalaya; boulder and gravel terraces on the valley floors
SK-Z1 Southern hills and valleys: SK-A Lower valleys (Rangpo–Singtam–Melli–Jorethang) The Teesta, Rangit and Rongni Chu valley floors and their river terraces below about 1,000 m: Rangpo, Singtam, Melli, Majitar and Jorethang, the valley parts of Namchi and Pakyong districts and the Teesta valley floor from Singtam down to the State border; boundaries [TBC] None with a long record in the sub-area; Gangtok and Tadong lie in SK-B and do not reach it under Clause 2.3.6(h) FER 2(a) 2% / 1% AEP 24-h: Singtam and Rangpo 280 / 360 mm, Jorethang 360 / 400 mm, Melli 360 / 440 mm (NEER reading, ±1 contour). NIH-DHAARA 50-yr 24-h 282 mm at Rangpo and 284 mm at Jorethang (comparison only). Valley-floor rule of Clause 4.11; recharge only on tested terrace gravels above the 1% AEP flood level and outside the 2023 aggradation zone. Receiving waters: the Teesta at Singtam, Rangpo and Melli on a bed raised in October 2023 (CWC levels at Khanitar, Melli and Singtam, with the conflict at Melli; none at Rangpo [TBC]); the Rangit at Majitar and Jorethang; the release reaches of Teesta-V, Teesta-VI, the Teesta Low Dam projects and Jorethang. Kalimpong's 419.2 mm (5 October 1968, IMD) is flagged on Form 2-1 for Melli, Rangpo and Jorethang
SK-Z1 Southern hills and valleys: SK-B Ridge towns (Gangtok–Pakyong–Namchi–Gyalshing) The ridges and slopes of about 1,000–2,500 m: Gangtok with Tadong and Ranipool, Pakyong, Namchi, Ravangla, Gyalshing (Geyzing), Pelling and Soreng; two record-check domains, east and west of the Teesta (Clause 2.3.6(h)); boundaries [TBC] Gangtok (42299), the Meteorological Office at 27°20′ N, 88°38′ E and 1,765 m (IMD); Tadong (22209) FER 2(a) 2% / 1% AEP 24-h: Gangtok and Pakyong 240 / 320 mm, raised to 270.3 / 320 mm by Gangtok's record of 310.3 mm (30 May 1975) within 25 km east of the Teesta; Ravangla 280 / 320 mm, Gyalshing 280 / 360 mm, Namchi 320 / 400 mm, Soreng 320 / 400 mm (not read; the higher of Gyalshing and Namchi [TBC]). NIH-DHAARA 50-yr 24-h 195 mm at Gangtok (comparison only). Hill rule of Clause 4.11; stability zones of 2021. Receiving waters: steep jhoras to the Rani Khola, the Roro Chu, the Rongni Chu, the Rangit and the Teesta, with free outfalls (Clause 5.8.5(a)). The Gangtok landslides of June 1997 (as reported)
SK-Z2 North Sikkim The Teesta valley above Dikchu and the land of Mangan district north of it, in subzone 2(a) but north of the plates' last contour, where no contour is drawn (Clause 2.3.6(b)) Singhik and Dikchu (ordinary rain gauges of the CWC 2(a) report, record lengths [TBC]); Mangan and Chungthang gauges; the Lachen automatic weather station and the India-WRIS Lachen station [TBC] No CWC value: SK-B1 takes the record floors of Clause 2.3.6(c)(ii), SK-C the plate's last values of Clause 2.3.6(c)(iii). The GLOF corridors of the Teesta, the Lachen Chu and the Lachung Chu, and 40 high-risk glacial lakes (State affidavit before the NGT, 2026), are screened under Clause 2.3.6(i)
SK-Z2 North Sikkim: SK-B1 Middle Teesta valley (Dikchu–Mangan–Singhik–Chungthang) The Teesta valley and its slopes from Dikchu to the Lachen–Lachung confluence at Chungthang, below about 2,500 m, including Mangan town. (The research for this Manual put Mangan town in SK-B and Chungthang in SK-C; both are here because no plate contour reaches them and because they share the valley of the Singhik and Dikchu records.) Boundaries [TBC] Singhik (504.2 mm, 12 May 1981) and Dikchu (400.8 mm, 25 August 1969) (CWC, 2(a), Table 7); hydropower gauges (Teesta-V, Dikchu, Chuzachen) [TBC] 24-h not less than 464.2 / 504.2 mm at 2% / 1% AEP until a station fit of at least 25 years is made, then not below 360.8 / 400.8 mm (Clause 2.3.6(c)(ii)); probably high. The plate implies 200–240 mm at 50 years; NIH-DHAARA 183 mm at Mangan and 154 mm at Chungthang at 50 years (comparison only). Hill rule of Clause 4.11. Receiving waters: the Teesta in the GLOF corridor, the reservoir of Teesta-V at Dikchu and the site of Teesta-III at Chungthang, under restoration (State affidavit before the NGT, 2026). The June 2024 slides in Mangan district (as reported)
SK-Z2 North Sikkim: SK-C High valleys (Lachen–Lachung–Thangu) The Lachen Chu and Lachung Chu valleys above Chungthang and the land above about 2,500 m, with the army and hydropower camps; seasonal snow, glaciers and the glacial lakes; boundaries [TBC] Lachen automatic weather station (hourly data of 2023 used by Sattar et al., 2025); India-WRIS Lachen station [TBC] 24-h not less than 240 / 320 mm at 2% / 1% AEP (Clause 2.3.6(c)(iii)); the Singhik and Dikchu floors do not reach it. NIH-DHAARA 50-yr 24-h 138 mm at Lachen and 121 mm at Lachung (not used). Every cross-drainage structure and outfall of more than 1 km², and every catchment with permanent snow, a glacier or a mapped glacial lake, has a site-specific study with GLOF, landslide-lake and debris-flow screening (Clause 2.3.6(i)). The South Lhonak lake, whose outburst of 3–4 October 2023 began the cascade down the Teesta, and the Chaten landslide near Lachen of 1 June 2025 (as reported)

Annex 2B — Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule

Supports Clauses 2.6.1 to 2.6.4 of Chapter 2.

To be prepared. This annex will tabulate, for each zone of Annex 2A, the ratios of the t-hour to the 24-hour design depth from NIH-DHAARA, which are derived from hourly records, against the ratios implied by IMD Das et al. (2022) and by the one-third rule. It needs NIH-DHAARA depths for each duration at representative points in each zone (NIH), IMD recording-gauge data and the IDF values of Das et al. (2022) (IMD). Until it is published, sub-daily depths are read directly from NIH-DHAARA or an approved station IDF (Clause 2.6.1). Where only daily depths are available, the ratios used are those agreed with the Authority, which in Sikkim are those of Clause 2.3.6(f) in every sub-area of Table 2B.1, the ratios of the CWC report for subzone 2(a), applied to the 24-hour depth of Clause 2.3.6(c) or (d) after the record check of Clause 2.3.6(h), with the 1-hour limit of Clause 2.3.6(g) where a station fit replaces them (Clause 2.6.2), and are recorded on Form 2-1. The one-third rule is not used (Clause 2.6.4).

2B.1 The first row of Table 2B.1 gives the ratios of the one-third rule P(t) = P(24)·(t/24)^(1/3), for comparison only. The 1, 3, 6 and 12 h values are those stated in the commentary to Clause 2.6; the 2 h value is computed from the same formula. The rule shall not be used for design unless this annex confirms it for the zone concerned (Clause 2.6.4).

Table 2B.1 — Ratios P(t)/P(24h) by zone (layout)

Zone Source 1 h 2 h 3 h 6 h 12 h 24 h
All (reference only, not for design) One-third rule 0.35 0.44 0.50 0.63 0.79 1.00
SK-Z1 (SK-A Lower valleys; SK-B Ridge towns) and SK-Z2 (SK-B1 Middle Teesta valley; SK-C High valleys) CWC FER 2(a), NB/18/1991, §3.1.2, p. 24, 50-yr basis, 12 IMD self-recording rain gauges, none identified in Sikkim (interim design ratios in every sub-area, Clause 2.3.6(f); 2-h value from Fig. 10, equal to logarithmic interpolation; 9 h 0.720, 15 h 0.875, 18 h 0.930). On the 24-h depth of Clause 2.3.6(c) or (d) after Clause 2.3.6(h); 72-h = 24-h × 1.75 (Clause 2.3.6(e)) 0.260 0.37 0.457 0.615 0.805 1.00
Every sub-area, every 24-h depth below 2% AEP Growth factors of Clause 2.3.6(d), set by this Manual: the 50%, 20%, 10% and 4% AEP 24-h depths = the 2% AEP depth after Clause 2.3.6(h) × 0.42, 0.61, 0.73 and 0.89 (upper envelope of the twelve NIH-DHAARA growth curves), with the 4% AEP depth not below Plate 8 where the plate draws one; not ratios of duration            
SK-B1, 24-h depths Floor of Clause 2.3.6(c)(ii), set by this Manual: not less than 464.2 mm at 2% AEP and 504.2 mm at 1% AEP (Singhik, CWC, 2(a), Table 7); once a station fit of at least 25 years governs, not below 360.8 mm and 400.8 mm (Dikchu); not ratios of duration            
SK-C, 24-h depths Floor of Clause 2.3.6(c)(iii), set by this Manual: not less than 240 mm at 2% AEP and 320 mm at 1% AEP (the Plate 9 and 10 readings at Gangtok carried north); not ratios of duration            
Every sub-area, where a station fit replaces Clause 2.3.6(f) 1-hour limit of Clause 2.3.6(g), set by this Manual: 1-h ratio not below 0.26            
SK-B: Gangtok cell NIH-DHAARA, IMDAA, 50-yr (queried 14 Nov 2026; comparison only) 0.16 0.27     0.76 1.00
SK-B: Pakyong cell NIH-DHAARA, IMDAA, 50-yr (comparison only; the 1-h and 2-h maxima of the twelve cells) 0.19 0.31     0.78 1.00
SK-B1: Mangan cell NIH-DHAARA, IMDAA, 50-yr (comparison only) 0.16 0.27     0.74 1.00
SK-C: Lachung cell NIH-DHAARA, IMDAA, 50-yr (comparison only; the lowest 1-h ratio of the twelve cells) 0.13 0.22     0.70 1.00

2B.2 Depths from fixed observation windows are converted to true-interval depths with the factors of Clause 2.6.3, repeated in Table 2B.2. They are the standard WMO (Hershfield) values and are not provisional.

Table 2B.2 — Fixed-interval adjustment factors (Clause 2.6.3)

Number of fixed observation intervals in the duration Factor
1 1.13
2 1.04
3–4 1.02

Annex 2C — Grid-to-point factors

Supports Clauses 2.7.1 and 2.7.4 of Chapter 2.

To be prepared. This annex will give the factors that convert grid-average design depths (for example from 0.25° cells) to point depths, by zone, duration and AEP. It needs paired frequency analyses of IMD gridded rainfall and of the IMD and State gauges inside each cell (IMD, the gauges of the Water Resources Department, the hydro-meteorological gauges of the hydropower projects, the India-WRIS station at Lachen and the Lachen automatic weather station [TBC]), the benchmark points of Annex 2A, and a stated method for deriving the factors. Until it is published, design depths are taken as point values from NIH-DHAARA or an approved station IDF (Clauses 2.3.1 and 2.3.2). Grid-average values are not used as design depths unless a conversion agreed with the Authority is recorded on Form 2-1 (Clause 1.11.5).

2C.1 The commentary to Clause 2.7 shows why the factors matter. In Sikkim NIH-DHAARA was queried at thirteen points for this Manual. In the south its reanalysis cells lie within about one contour of the CWC plates, but its Gangtok cell gives 195 mm at 50 years in 24 hours, against the 310.3 mm that IMD's Gangtok gauge recorded on 30 May 1975, and its Mangan cell 183 mm, against the 504.2 mm recorded at Singhik (NIH-DHAARA, queried 14 Nov 2026; IMD, Extremes; CWC, 2(a), Table 7). Gauges a few kilometres apart differ widely: on 25 September 2005 Tadong recorded 212.5 mm and Gangtok 141.0 mm (IMD, Extremes). Values of this kind are grid- or area-average values and need these factors before any use as point depths; under Clause 2.3.6 NIH-DHAARA is never a design value in Sikkim and is reported for comparison only (Clause 2.3.6(m)).

Table 2C.1 — Grid-to-point factors (layout)

Zone Grid product and cell size Duration (h) AEP Factor (point / grid) Stations used Years of record
    24        
    48        
    72        

Annex 2D — Sikkim temporal patterns (Huff curves)

Supports Clauses 2.9.3 and 2.9.4 of Chapter 2, and Clause 11.7.3 of Chapter 11.

To be prepared. This annex will give dimensionless time-distribution (mass) curves of Sikkim storms, in the form introduced by Huff (1967), by zone, storm-duration class and quartile, at stated probability levels. It needs storm hyetographs from recording gauges and automatic weather stations (IMD, its recording gauges and automatic weather stations in the State under the Meteorological Centre Gangtok, among them Gangtok (42299) and Tadong (22209), the Lachen automatic weather station used by Sattar et al. (2025), and any recording gauges of the hydropower projects, SSDMA and GSCDL, whose hourly archive is a first data request of Clause 2.3.6(a) [TBC]), separated into independent storms by a stated rule, and the Gangtok storm of 30 May 1975 (310.3 mm in 24 hours), the Gangtok storm of 9 June 1997 (223.8 mm), the storm of 25 September 2005 (212.5 mm at Tadong and 141.0 mm at Gangtok), the Singhik storm of 12 May 1981 (504.2 mm), the rain of 12–13 June 2024 over Mangan district and of 30 May–1 June 2025 over north Sikkim, for which no IMD rainfall was found [TBC], and the hourly record of the Lachen automatic weather station for September–October 2023 among them. Until it is published, design storms use the alternating-block pattern of Clause 2.9.1 and the 48- and 72-hour pattern of Clause 2.9.2; for catchments of 25–5,000 km², the CWC Flood Estimation Report curves may be used with a sensitivity run under Clause 2.9.1 (Clause 2.9.4). SCS Type distributions are not used (Clause 2.9.3). For the disaggregation of daily records in continuous simulation (Clause 11.7.3), the method is agreed with the Authority and recorded (Clause 1.11.5).

Table 2D.1 — Cumulative fraction of storm depth against cumulative fraction of storm time (layout, one table per zone, duration class and quartile)

Fraction of storm time 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
10% probability curve 0                   1.0
50% probability curve 0                   1.0
90% probability curve 0                   1.0

2D.1 Each table shall state the zone, the duration class, the quartile (the quarter of the storm in which most rain fell), the number of storms analysed and the period of record.

Reference: Huff, F.A. (1967). Time distribution of rainfall in heavy storms. Water Resources Research 3(4), 1007–1019.


Annex 2E — Retention percentile depths by zone

Supports Clauses 2.8.3 and 2.10.1 to 2.10.2 of Chapter 2, Clause 4.4 of Chapter 4 and Chapter 8.

To be prepared. This annex will give, for each zone of Annex 2A, the retention design depth P_R: the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record (Clause 2.10.1). It needs long daily records at stations in each zone (IMD, the gauges of the Water Resources Department, the hydro-meteorological gauges of the hydropower projects, the India-WRIS station at Lachen and the Lachen automatic weather station [TBC]) and IMD gridded data with the factors of Annex 2C where stations are sparse. Until it is published, P_R is computed by the definition of Clause 2.10.1 from the long-term daily record of a station agreed with the Authority, by the steps in 2E.1, and recorded on Form 2-1 (Clause 1.11.5).

2E.1 Computing P_R from a daily record.

  1. Take the daily (24-hour) rainfall series of the station for its full record.
  2. Keep only the days with rain of 2.5 mm or more (wet days).
  3. Rank the wet-day depths and take the depth not exceeded on 90% of them (the 90th percentile).
  4. Do not apply the climate factor (Clause 2.8.3) or the fixed-interval factor; P_R is a statistic of everyday rainfall, not an AEP design depth.
  5. Record the station, the period of record, the number of wet days and P_R on Form 2-1.

Table 2E.1 — Retention depth P_R by zone (layout)

Zone Stations or grid cells used Period of record Number of wet days (≥ 2.5 mm) P_R, 90th percentile (mm) Issued on
SK-Z1 Southern hills and valleys          
SK-Z2 North Sikkim          

Form 2-1 — Design Rainfall Sheet

Supports Clauses 2.3 to 2.13 of Chapter 2, and Clause 10.4.1(d) of Chapter 10.

Draft form — Sikkim Stormwater Design Manual, Draft v1.0. One sheet for each hydrologic submittal. The steps follow Figure 2.3 of Chapter 2.

Table 2F.1 — Form 2-1: site, source and storms

No. Item (clause) Entry
A. Site (Clause 2.13, item 1)
A1 Project and site ______
A2 Site coordinates (latitude, longitude, decimal degrees) ______
A3 Rainfall zone (Annex 2A, or as agreed with the Authority) ______
A4 Contributing catchment area (km²) (Clause 2.7) ______
A5 Design life: more than 25 years / temporary works, 5 years or less (Clause 2.8.2) ______
A6 Outfall under tidal or river backwater influence: Yes / No (Clauses 2.5.3, 2.12) ______
B. Source (Clauses 2.3, 2.3.5; item 2)
B1 NIH-DHAARA: version or access date ______
B2 Coordinates queried ______
B3 Screenshot or export of the values extracted attached: reference ______
B4 Station IDF used (Clause 2.3.2): No / Yes — station, ID, distance from site (km) ______
B5 Station IDF: years of recording-gauge data (30 or more); published or approved by ______
B6 Station IDF: change of terrain or coastal exposure between gauge and site: None / describe ______
C. AEPs and durations (Clauses 2.4, 2.5)
C1 Elements designed and their AEPs (Table 2.1) ______
C2 Conveyance: Tc and design duration (not less than 10 min) (Clause 2.5.1) ______
C3 Storage: durations checked from {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48 and 72 h included (Clause 2.5.2) ______
C4 Critical duration found for each storage element ______
D. Conversions
D1 Sub-daily depths: read directly / from Annex 2B ratios / from ratios agreed with the Authority (Clauses 2.6.1, 2.6.2) ______
D2 Fixed-interval factor applied: none (true-interval source) / 1.13 / 1.04 / 1.02 (Clause 2.6.3) ______
D3 Grid-to-point factor: not needed (point source) / Annex 2C / agreed value (Clause 2.7.1) ______
D4 ARF: 1.0 (10 km² or less; single-site storage) / CWC curve / interpolated (Clauses 2.7.2–2.7.4) ______
D5 Climate factor: 1.20 (≤ 6 h) and 1.10 (> 6–72 h) / 1.0 temporary works / projected depths under Clause 2.8.4 ______
E. Cross-checks (Clause 2.3.3; item 4)
E1 IMD Das et al. (2022) values for 1–24 h: reported in Table 2F.2 ______
E2 CWC subzone 2(a) (in sub-areas SK-B1 and SK-C no contour is drawn: enter "none") 24-hour point value, catchments of 25–5,000 km²: subzone used ______
E3 CWC floor governs for any AEP: No / Yes — AEPs ______
F. Retention depth (Clause 2.10)
F1 P_R (mm) and source: Annex 2E zone value / computed under Annex 2E, 2E.1 — station and period ______
F2 No climate factor applied to P_R (Clause 2.8.3): confirmed ______
G. Design storms (Clauses 2.9, 2.11, 2.12; items 5 and 6)
G1 Storms up to 24 h: alternating block, peak at 50%; time step (≤ Tc/3 and ≤ 15 min) ______
G2 48 and 72 h storms: built under Clause 2.9.2 (Table 2F.3) ______
G3 Other pattern used: none / Annex 2D / CWC FER with sensitivity run (Clauses 2.9.3, 2.9.4) ______
G4 Hyetographs attached as a table and a plot for each design storm: reference ______
G5 AMC: III for every design storm of 1 May–30 September in every sub-area, whatever its duration; III for every design storm of 1 April–31 October on valley-floor land below the 1% AEP flood level, on the 2023 aggradation zone, where the seasonal high water table is within 2 m and in stability zones 3–6; III at any time in catchments draining to a hydropower reservoir, its backwater, a release reach below a dam or a river reach above its CWC warning level; at any other site or time, III for a storm that follows or contains a 5-day total of more than 53 mm; II otherwise (Clause 2.11.4) ______
G6 Pre-development condition: greenfield, open land in good condition for the mapped HSG (Clause 2.11.5) ______
G7 Release criterion: standard, Q_post ≤ 0.9 × Q_pre (Clause 2.11.2) / flood-sensitive, mixed-frequency rule (Clause 2.11.3) ______
G8 Tailwater joint cases run (Clause 2.12): case (a) MHWS + sea-level allowance; case (b) 10% AEP 48 h storm with 1% AEP still-water level + sea-level allowance; governing case ______
H. Prepared by
H1 I confirm that the values above are those extracted and used in the submittal. Name, registration number, signature, date ______

Design depth = source depth × fixed-interval factor × grid-to-point factor × ARF × climate factor. Where the design depth is lower than the CWC floor for the same AEP, the floor is adopted (Clause 2.3.3).

Table 2F.2 — Form 2-1: depth table (Clause 2.13, item 3)

AEP (T-yr) Duration Source depth (mm) Fixed-interval factor Grid-to-point factor ARF Climate factor Design depth (mm) IMD Das et al. (2022) (mm) CWC floor (mm) Adopted depth (mm)
                     
                     
                     
                     

Table 2F.3 — Form 2-1: 48- and 72-hour storm construction (Clause 2.9.2)

AEP (T-yr) Duration (h) Total design depth (mm) 24 h design depth, final 24 h (mm) Remainder (mm) Hours before the final 24 h Uniform intensity before the final 24 h (mm/h)
  48       24  
  72       48