Annexes to Chapter 3Hydrologic Methods
These annexes support Chapter 3. Annex 3C sets out benchmark test problems for software acceptance, and Forms 3-1 and 3-2 are the submittal forms required by Clause 3.17. Annexes 3A, 3B, 3D and 3E need survey, gauging or published report data that this draft does not yet contain; each gives the intended layout and the interim rule of Chapter 3 that applies until it is published. The forms are draft forms and have no statutory status.
Annex 3A — Tripura soil series to HSG lookup; seasonal high water table map
Supports Clauses 3.7 and 3.10 of Chapter 3.
To be prepared. This annex will contain (a) a lookup from each soil series mapped in Tripura to its hydrologic soil group (HSG), in both the drained and the undrained state, and (b) a map of the depth to the seasonal high groundwater table in the monsoon season (April–October). It needs NBSS&LUP and Agriculture Department, Tripura (soil survey) [TBC] series maps with their scales, measured saturated hydraulic conductivity and depth to an impermeable layer for each series, and observation-well records from the Central Ground Water Board and the PWD (WR), supplemented by piezometers in the recent flood plains and lunga floors (lunga, Bengali লুঙ্গা: the land records' "Flat lands between tillas"; tilla, Bengali টিলা: "Hillock") of every valley, where the CGWB's dug wells in West Tripura stood 0.22–6.64 m below ground in November 2017, central Agartala between the Haora embankment and the Katakhal and the other land behind embankments, the margins of the pukurs, dighis and beels, filled ponds and lunga fills, and the tilla tops and benches where the tilla rule of Clause 4.11 may allow infiltration. Until it is published, use the interim rules of Chapter 3: assign HSG from measured saturated hydraulic conductivity and depth to an impermeable layer or water table by the criteria of NEH Part 630, Ch. 7 (Clause 3.7.2); verify it by site infiltration tests wherever retention relies on infiltration (Clause 3.7.3); take the seasonal high water table from site piezometers, trial pits or the nearest observation well (Clause 3.10.2); and assign HSG D wherever that level is within 0.6 m of the ground surface (Clause 3.10.1).
Table 3A.1 — Soil series to HSG lookup (layout)
| Soil series | District(s) | Taxonomic class | Surface texture | Saturated hydraulic conductivity (mm/h) | Depth to impermeable layer (m) | HSG, drained | HSG, undrained | Source map and scale |
|---|---|---|---|---|---|---|---|---|
Table 3A.2 — Seasonal high water table, by mapping unit (layout)
| Mapping unit or grid cell | Observation wells used | Years of April–October record | Highest April–October level below ground (m) | Within 0.6 m of ground (Clause 3.10.1)? | Data source |
|---|---|---|---|---|---|
Annex 3B — Tripura CN calibration and supplementary land covers (forest of the hill ranges and tillas, lunga land, beel and haor beds, cut tilla slopes and fills, filled ponds and lunga fills)
Supports Clauses 3.8 and 3.15 of Chapter 3.
To be prepared. This annex will contain (a) curve numbers calibrated against observed rainfall and runoff in Tripura catchments, compared with the TR-55 values of Table 3.5, and (b) curve numbers for land covers that Table 3.5 does not list: the forest of the hill ranges and tillas ("Nearly seventy-three per cent of the council's geographical area falls under forest classification", of the Tripura Tribal Areas Autonomous District Council's area, as reported); lunga land, the flat land between tillas that the land records class as "Flat lands between tillas" in their classification of land for agricultural purposes (Diversion of Land Rules, 2025, Appendix-I); the beds and margins of beels (বিল, "Watery land") and haors (হাওর, "Big watery land"), with the marshy and swampy land that the same list calls dhepa (ঢেপা, "Marshy land") and utla (উতলা, "Swampy land"), dry or shrunken at the start of the season; the cut slopes and fills of the tillas, bare or newly vegetated; and filled ponds and lunga fills, the "recently filled up … pond, lake, marshy" land of rule 32 of the Tripura Building Rules, 2017. It needs paired rainfall–runoff records for small gauged catchments of known cover and soil, from PWD (WR) gauging sites, agricultural research stations and tank gauges, analysed by event and by antecedent moisture. Until it is published: the pre-development reference stays open space in good condition for every site (Clause 3.3.2), so these covers do not enter the pre-development run; for off-site existing conditions, use the nearest Table 3.5 or TR-55 cover row, including the cultivated rows (Clause 3.8.3(c)), and state the row chosen and the reason on Form 3-1; land under standing water at the start of the design storm is modelled as water surface with no losses (Table 3.5; Clause 3.10.4(b)). Any departure from these defaults requires calibration under Clause 3.15 (Clause 3.15.1(d)).
Table 3B.1 — Supplementary land covers, AMC II (layout)
| Cover type | HSG A | HSG B | HSG C | HSG D | Ia ratio | Basis (catchments, events, years) |
|---|---|---|---|---|---|---|
| Forest of the hill ranges and tillas, with the litter recorded | ||||||
| Lunga land (the flat land between tillas), cultivated or fallow, ponded or dry at the start of the storm | ||||||
| Beel or haor bed or margin, or dhepa or utla marsh, dry or shrunken at the start of the storm | ||||||
| Cut tilla slope or fill, bare or newly vegetated | ||||||
| Filled pond or lunga fill (rule 32 of the Tripura Building Rules, 2017), with the depth and age of the fill recorded | ||||||
| Other (state) |
Table 3B.2 — CN calibration catchments (layout)
| Catchment | District | Area (km²) | Dominant HSG and cover | Events used | Table 3.5 CN | Calibrated CN | Calibrated ÷ Table 3.5 |
|---|---|---|---|---|---|---|---|
Annex 3C — Benchmark test problems for software acceptance
Supports Clauses 3.5, 3.6, 3.8, 3.9, 3.11, 3.12 and 3.16 of Chapter 3.
Purpose. Software not listed in Clause 3.16.1 shall reproduce the results of the five problems below (Clause 3.16.3). Each problem is fully specified and uses only the methods and tables of Chapter 3, so every answer can be checked by hand. The acceptance tolerance is ±5% on each tabulated result, the equivalence threshold of Clause 3.16.2; for closed-form results (Problems 3C-1 to 3C-4), software should agree to the rounding shown. The submittal shall report the software result next to each answer below.
Illustrative — not design values. The inputs (areas, intensities, rainfall depths, slopes and the basin) are chosen for testing only. They are not design data for any site.
Problem 3C-1 — Rational Method peak (Clause 3.5)
Inputs. A 2.0 ha catchment draining to one inlet: 1.2 ha concrete paving and roofs, C = 0.90 (Table 3.2, upper half of 0.80–0.95); 0.8 ha lawns on sandy soil, average slope, C = 0.15 (Table 3.2, upper half of 0.10–0.15). Design AEP 1% (100-yr). Rainfall intensity at Tc, including the climate factor: i = 120 mm/h.
Part (b): a separate 0.5 ha fully paved catchment, C = 0.90, design AEP 1%, i = 150 mm/h.
Table 3C.1 — Problem 3C-1 solution
| Step | Calculation | Result |
|---|---|---|
| Composite C (Clause 3.5.4) | (1.2 × 0.90 + 0.8 × 0.15) / 2.0 | 0.60 |
| Frequency factor (Table 3.3) | 1% AEP | Cf = 1.25 |
| C · Cf (≤ 1.0) | 0.60 × 1.25 | 0.75 |
| Peak flow (Clause 3.5.1) | 0.75 × 120 × 2.0 / 360 | Q = 0.500 m³/s |
| Part (b): C · Cf | 0.90 × 1.25 = 1.125, capped at 1.0 (Clause 3.5.3) | 1.00 |
| Part (b): peak flow | 1.00 × 150 × 0.5 / 360 | Q = 0.208 m³/s |
Problem 3C-2 — Time of concentration by the segment method (Clause 3.6)
Inputs. Pre-development flow path: sheet flow over greenfield, n = 0.15 (Clause 3.6.3), L = 30 m, S = 0.01; P2 (50% AEP 24-hour rainfall, no climate factor) = 80 mm. Shallow concentrated flow, unpaved, L = 200 m, S = 0.01. Channel flow, L = 400 m, bank-full velocity V = 1.0 m/s (given).
Table 3C.2 — Problem 3C-2 solution
| Segment | Calculation | Travel time |
|---|---|---|
| Sheet flow (Clause 3.6.2(a)) | 0.091 × (0.15 × 30)^0.8 / (80^0.5 × 0.01^0.4) = 0.2138 h | 12.83 min |
| Shallow concentrated (Clause 3.6.2(c)) | V = 4.918 × 0.01^0.5 = 0.4918 m/s; 200 / (3,600 × 0.4918) = 0.1130 h | 6.78 min |
| Channel (Clause 3.6.2(d)) | 400 / (3,600 × 1.0) = 0.1111 h | 6.67 min |
| Tc (Clause 3.6.1; ≥ 10 min) | 12.83 + 6.78 + 6.67 | 26.27 min |
| Lag (Clause 3.6.5) | 0.6 × 26.27 | 15.76 min |
Problem 3C-3 — SCS-CN runoff depth, AMC and Ia sensitivity (Clause 3.8)
Inputs. Pre-development reference on HSG C: CN = 74 at AMC II (Table 3.5), all pervious. Cumulative rainfall P = 100 mm; second case P = 25 mm.
Table 3C.3 — Problem 3C-3 solution
| Case | S (mm) | Ia (mm) | Runoff Q (mm), P = 100 mm | Runoff Q (mm), P = 25 mm |
|---|---|---|---|---|
| (a) AMC II, Ia = 0.2S: S = 25,400 / 74 − 254 | 89.24 | 17.85 | 39.38 | 0.53 |
| (b) AMC III, Ia = 0.2S: CN(III) = 23 × 74 / (10 + 0.13 × 74) = 86.75 | 38.80 | 7.76 | 64.93 | — |
| (c) AMC II, Ia = 0.05S: S0.05 = 25.4 × 1.33 × (89.24 / 25.4)^1.15 | 143.31 | 7.17 | 36.49 | 1.97 |
Runoff is Q = (P − Ia)² / (P − Ia + S). Case (c) gives less runoff than case (a) at 100 mm but more at 25 mm, as Clause 3.8.5 and Figure 3.3 describe.
Problem 3C-4 — Separate vs composite impervious representation, and SCS unit hydrograph peak (Clauses 3.9 and 3.11.2)
Inputs, part (a). A site that is 50% directly connected impervious (CN 98) and 50% open space on HSG B (CNp = 61), AMC II, Ia = 0.2S, P = 25 mm.
Inputs, part (b). A sub-area of A = 2.5 km² with Tc = 1.0 h and computation interval Δt = 0.1 h.
Table 3C.4 — Problem 3C-4 solution
| Step | Calculation | Result |
|---|---|---|
| (a) Impervious half (Clause 3.9.2) | S = 5.18 mm, Ia = 1.04 mm; Q = 23.96² / (23.96 + 5.18) | 19.70 mm |
| (a) Pervious half | S = 162.39 mm, Ia = 32.48 mm > P | 0 mm |
| (a) Area-weighted runoff, separate sub-areas | 0.5 × 19.70 + 0.5 × 0 | 9.85 mm |
| (a) Composite CN (Clause 3.9.4) | 61 + 0.50 × (98 − 61) | 79.5 |
| (a) Runoff with composite CN | S = 65.50 mm, Ia = 13.10 mm; Q = 11.90² / (11.90 + 65.50) | 1.83 mm |
| (b) Interval check (Clause 3.11.3(a)) | 0.133 × 1.0 = 0.133 h ≥ Δt = 0.1 h | satisfied |
| (b) Lag and time to peak (Clause 3.11.2) | tL = 0.6 × 1.0 = 0.60 h; tp = 0.1 / 2 + 0.60 | tp = 0.65 h |
| (b) Unit hydrograph peak, Q = 1 mm | 0.208 × 2.5 × 1 / 0.65 | qp = 0.800 m³/s per mm |
Part (a) reproduces the comparison in the commentary to Clause 3.9 (about 9.9 mm vs 1.8 mm).
Problem 3C-5 — Level-pool (modified Puls) storage routing (Clause 3.12.1)
Inputs. A detention basin with vertical sides and plan area 500 m², with the stage–storage–discharge relationship of Table 3C.5. Triangular inflow hydrograph: 0 at t = 0, rising linearly to 0.50 m³/s at t = 30 min, falling linearly to 0 at t = 90 min. Basin empty at t = 0. Routing interval Δt = 10 min (600 s). No tailwater.
Table 3C.5 — Problem 3C-5 stage–storage–discharge relationship
| Stage (m) | Storage S (m³) | Outflow O (m³/s) |
|---|---|---|
| 0.0 | 0 | 0.00 |
| 0.5 | 250 | 0.05 |
| 1.0 | 500 | 0.10 |
| 1.5 | 750 | 0.15 |
| 2.0 | 1,000 | 0.20 |
| 2.5 | 1,250 | 0.25 |
Method. The storage-indication equation is (I1 + I2) + (2S1/Δt − O1) = (2S2/Δt + O2). The table gives O = S / 5,000 (S in m³, O in m³/s), so 2S/Δt + O = 17.667 O and 2S/Δt − O = 15.667 O, and each step is O2 = [(I1 + I2) + 15.667 O1] / 17.667. Software interpolating linearly in Table 3C.5 shall give the same result.
Table 3C.6 — Problem 3C-5 routed outflow
| Time (min) | Inflow I (m³/s) | Outflow O (m³/s) | Storage (m³) | Stage (m) |
|---|---|---|---|---|
| 0 | 0.0000 | 0.0000 | 0.0 | 0.000 |
| 10 | 0.1667 | 0.0094 | 47.2 | 0.094 |
| 20 | 0.3333 | 0.0367 | 183.3 | 0.367 |
| 30 | 0.5000 | 0.0797 | 398.4 | 0.797 |
| 40 | 0.4167 | 0.1226 | 612.8 | 1.226 |
| 50 | 0.3333 | 0.1511 | 755.7 | 1.511 |
| 60 | 0.2500 | 0.1670 | 835.2 | 1.670 |
| 70 | 0.1667 | 0.1717 | 858.6 | 1.717 |
| 80 | 0.0833 | 0.1664 | 832.1 | 1.664 |
| 90 | 0.0000 | 0.1523 | 761.5 | 1.523 |
| 120 | 0.0000 | 0.1062 | 531.1 | 1.062 |
| 180 | 0.0000 | 0.0517 | 258.3 | 0.517 |
Results. Peak outflow 0.172 m³/s at 70 min; peak storage 859 m³; peak stage 1.72 m. The inflow peak of 0.50 m³/s is reduced to 34% of its value.
Table 3C.7 — Benchmark results to be reported by the applicant
| Problem | Result | Benchmark | Software result | Difference (%) | Within ±5%? |
|---|---|---|---|---|---|
| 3C-1 | Q, main case (m³/s) | 0.500 | |||
| 3C-1 | Q, part (b) (m³/s) | 0.208 | |||
| 3C-2 | Tc (min) | 26.27 | |||
| 3C-3 | Q, case (a), P = 100 mm (mm) | 39.38 | |||
| 3C-3 | Q, case (b), P = 100 mm (mm) | 64.93 | |||
| 3C-3 | Q, case (c), P = 100 mm (mm) | 36.49 | |||
| 3C-3 | Q, case (c), P = 25 mm (mm) | 1.97 | |||
| 3C-4 | Runoff, separate sub-areas (mm) | 9.85 | |||
| 3C-4 | Runoff, composite CN (mm) | 1.83 | |||
| 3C-4 | qp (m³/s per mm) | 0.800 | |||
| 3C-5 | Peak outflow (m³/s) | 0.172 | |||
| 3C-5 | Peak storage (m³) | 859 |
Annex 3D — Peak rate factor study for flat coastal land
Supports Clauses 3.11.5 and 3.15 of Chapter 3.
Not required in Tripura. Tripura is landlocked, so no land in the State meets Clause 3.11.5(a), and the standard factor 484 (PRF′ = 0.208) applies to all land (Clause 3.11.5); the Feni and the Muhuri reach the sea only in Bangladesh (NEER's reading). The lunga floors, the recent flood plains and the land behind the embankments are flat and slow to drain, but they are not coastal plain; their slow response is represented by storage, pumping and backwater (Clauses 3.10.4, 3.12.1 and 3.12.4) and by the outfall-closed check of Chapter 5, not by a lower peak rate factor. The annex and the layout of Table 3D.1 are kept only so that the annex numbering is unchanged.
Table 3D.1 — Calibrated peak rate factors (layout)
| Catchment | Area (km²) | Mean slope (m/m) | Drainage condition | Events used | Calibrated PRF (US customary) | PRF′ (SI) | Range of applicability |
|---|---|---|---|---|---|---|---|
Annex 3E — CWC SUH parameters for Tripura (subzone 2(c): no CWC report; the subzone 2(b) relationships as a cross-check only), with worked example
Supports Clauses 3.4.3 and 3.11.4 of Chapter 3.
To be prepared. This annex will tabulate, for CWC subzone 2(b) (South Brahmaputra), whose relationships this Manual uses in Tripura only as a cross-check on the site study, because CWC has published no report for subzone 2(c) (Barak and others), in which the State lies, the regression relationships for the synthetic unit hydrograph parameters, the design storm duration, loss rate, base flow, areal reduction and time distribution, each with its reference to the Flood Estimation Report, and a worked example for one catchment. It needs a CWC Flood Estimation Report for subzone 2(c) (Barak and others), which CWC has never published, with written confirmation from CWC that Tripura lies in subzone 2(c) and that no report for it, or for the rivers of the State that flow to the Meghna in Bangladesh, exists or is in preparation [TBC]; until then, the South Brahmaputra subzone 2(b) report (Revised; Design Office Report No. SB-2(b)/R-4/44/99, March 2000), whose plates stop at about 25° N and whose corrigendum strikes out its one mention of Tripura, for its areal reduction curves (Annex 4.3, read by optical character recognition only [TBC]) and its unit hydrograph relationships, used only as a cross-check (see the References of Chapter 3); the stage records, rating curves, gauge zeros and datums of the CWC sites on the Manu, the Dhalai, the Khowai, the Gumti, the Haora, the Muhuri, the Juri and the Burima, of which only highest and danger levels transcribed by others were read [TBC]; and bridge-catchment data held by the Northeast Frontier Railway and RDSO for the railway to Agartala and Sabroom [TBC], transcribed and checked against the published reports, and a catchment with physiographic parameters measured from survey or a DEM. Until it is published, take all SUH inputs directly from the applicable Flood Estimation Report (Clause 3.11.4(a)), apply the 24-hour design rainfall of Clauses 2.3.3(b) and 2.7.3 with the climate factor of Clause 2.8 (Clause 3.11.4(b)), report the SUH result alongside the HEC-HMS or SWMM result for the existing natural condition (Clause 3.11.4(c)), and, where the hydrograph model gives a lower 1% AEP peak, either justify it by calibration under Clause 3.15 or adopt the SUH peak (Clause 3.11.4(d)).
Table 3E.1 — SUH relationships by subzone (layout)
| Parameter | Symbol | Unit | Subzone 2(b) (South Brahmaputra) relationship, computed in Tripura only as a cross-check | In Tripura (subzone 2(c), no CWC report): the site study |
|---|---|---|---|---|
| Peak discharge of the 1-hour unit hydrograph | Qp | m³/s | Qp = 0.905 A^0.758 (Eq. 3.4.3.2); the peak depends on the catchment area alone | From the calibrated SCS, Clark or Snyder unit hydrograph of the site study (Clause 3.11.1) |
| Peak discharge per unit area | qp | m³/s per km² | qp = Qp / A | As above |
| Time from centre of unit rainfall to peak | tp | h | tp = 2.87 qp^−0.839 | From the segment Tc of Clause 3.6.2, split at the break of slope between tilla or hill and lunga (Commentary to Clause 3.7, rules (a) and (c)) |
| Width of UH at 50% of peak | W50 | h | W50 = 2.304 qp^−1.035 | Not used |
| Width of UH at 75% of peak | W75 | h | W75 = 1.339 qp^−0.978 | Not used |
| Width of rising limb at 50% of peak | WR50 | h | WR50 = 0.814 qp^−1.018 | Not used |
| Width of rising limb at 75% of peak | WR75 | h | WR75 = 0.494 qp^−0.966 | Not used |
| Base width of UH | TB | h | TB = 2.447 tp^1.157 | From the site study |
| Time to peak from start of rise | Tm | h | Tm = tp + tr/2 | From the site study |
| Unit duration | tr | h | 1 | The model time step (Clause 2.9.1) |
| Design storm duration | TD | h | TD = 1.1 tp | Every duration of Clause 2.5.2, up to 72 hours |
| Design loss rate | — | mm/h | 3.5 (printed "0.35 cm/hr", the modal value of 100 flood events, as in the report of 1984); for the cross-check only | SCS-CN with the interim HSG of Clause 3.7.2 and the AMC of Clause 3.8.4; the 2(b) loss rate is not used |
| Design base flow | — | m³/s per km² | 0.05 (68 of 100 events in the range 0.01–0.09); for the cross-check only | From the calibration gauge's record, or 0.05 m³/s per km² until one is analysed (set by this Manual) |
| Ratio of t-hour to 24-hour rainfall | — | — | 10-yr, partial duration, mean of 6 self-recording gauges outside Tripura: 1 h 0.48; 3 h 0.62; 6 h 0.74; 12 h 0.87; 24 h 1.00 (Table 4.1). Not used in Tripura, not even for the cross-check | The t-hour depths of Clause 2.3.6(f): NIH-DHAARA's own depths under the governing-cell rule, not below the subzone 2(a) ratios (1 h 0.260; 3 h 0.457; 6 h 0.615; 12 h 0.805) × the 24-hour depth, and not below the short-storm floors of Clause 2.3.6(g); the cross-check uses the same depths |
| Time distribution of rainfall | — | cumulative fraction by hour | 1,040 storms in five duration groups; the tables of Annex 4.4 not read [TBC] | The design hyetographs of Clause 2.9 |
| Conversion of 1-day to 24-hour rainfall | — | factor | 1.15 | Applies to any IMD daily value used under Clause 2.3.6(d) (Clause 2.6.3) |
| Areal reduction factor | ARF | % of point rainfall | Annex 4.3, read by optical character recognition only [TBC]: at 50 km², 93.75 (1 h), 94.25 (3 h), 95.50 (6 h), 97.00 (12 h), 98.00 (24 h); at 100 km², 88.00, 90.00, 91.75, 94.50, 96.50; at 200 km², 78.50, 82.00, 85.50, 90.00, 94.00; at 300 km², 71.00, 75.50, 80.00, 87.50, 92.00; at 500 km², 64.50 (3 h), 71.25, 83.00, 88.50; at 1,000 km², 76.00 (12 h), 83.00; at 2,000 km², 77.50 (24 h) | The same curves, until a Tripura study replaces them (Clause 2.7.3; set by this Manual); none is applied to a single development site (Clause 2.7.4) |
| Calibration | — | — | None in Tripura: the 14 catchments are bridge sites in Assam, two of them on rivers that rise in Meghalaya | Required (Clause 3.15) against the CWC and State river gauges of the Commentary to Clause 3.7, rule (d), or surveyed flood marks |
| Catchment area for which the relationships apply | A | km² | more than 50 to 1,500; up to 5,000 "judiciously" | 25–5,000 km²; the cross-check is computed only within 50–1,500 km² |
| Report reference | — | — | SB-2(b)/R-4/44/99: §§3.4–3.7, Table 3.3, Table 4.1, Annex 4.3, the errata and the worked example | This Manual, Clauses 2.3.6, 2.7.3, 3.11.4 and 3.15 |
Note: relationships as printed in the CWC subzone 2(b) report (References of Chapter 3), read from a scanned copy; Table 3.3, its ratio table and its errata were checked against the page images by the neighbouring editions of this series, and its Annex 4.3 was read by optical character recognition only [TBC]. A is the catchment area in km². No CWC report covers Tripura. The 2(b) report states its extent as "latitude 25° 15' to 28° North approximately" and says the subzone is bounded "on the south by Barak Subzone 2 (c)"; its §2.4.2.1 mentioned "some parts of Tripura", and its corrigendum orders "omit 'and some parts of Tripura' from this line"; its Plate 9 stops at about 25° N, while Tripura lies between 22°56′ and 24°32′ N. Its Annexure 1.1 lists "2(c) | Barak and others | Barak | Barak, Kalden and Manipur rivers" (as printed), and no report for 2(c) was ever published: CWC's list has 21 reports for 24 of the 26 subzones. Every river of Tripura, the Haora, the Gomati, the Khowai, the Burima, the Muhuri and the Feni to the west and south, and the Manu, the Dhalai, the Juri, the Deo and the Longai to the north, leaves the State into Bangladesh and reaches the Meghna system, so the State falls in subzone 2(c) by elimination (NEER's reading, to be confirmed with CWC's subzone map [TBC]). Tripura is the first edition of this series whose whole area lies outside every published CWC report. No CWC, CDO, RDSO or railway small-catchment study for Tripura was found [TBC]. Why the 2(b) unit hydrograph is only a cross-check. It rests on 14 catchments with 100 bridge-years of record, gauged at railway bridges from 1961 to 1983 and at national-highway bridges from 1981; every one is a bridge site in Assam, two of them on rivers that rise in Meghalaya; none lies in Tripura and none drains to the Meghna; and its peak depends on area alone, so it gives the same unit hydrograph to a tilla catchment and to a flat lunga catchment of the same area. Its 50-yr peaks err by "+40.72% to −57.84%" on its own catchments. Carried across the border into a different basin it is a yardstick, not a design method. In Tripura, therefore, every catchment of 25–5,000 km² is designed by the site study of Clause 3.11.4 (Commentary to Clause 3.7, rule (d)); the 2(b) unit hydrograph is computed beside it for the natural condition, within its range of 50–1,500 km², with the depths of Clause 2.3.6 and the ARF above, and reported under Clause 3.11.4(c) and the reasonableness check of Clause 3.15.6. It is never the floor of Clause 3.11.4(d): where the calibrated site study gives a lower 1% AEP peak than the cross-check, the submittal shows the calibration that supports it (Clause 3.15), and where the site study cannot be calibrated, the higher of the two peaks is adopted (set by this Manual). The ARF curves are used in Tripura (Clause 2.7.3) because an areal reduction depends on storm size more than on the basin, because no Tripura ARF exists, and because they are the nearest published curves; they were read by optical character recognition only and are to be checked against the page images [TBC] (set by this Manual). The 2(b) ratios and isopluvials are not used in Tripura (Clause 2.3.6(b) and (f)). Gauges for calibration. CWC lists 12 sites in Tripura, two of them level-forecasting (the Manu at Kailashahar and the Gumti at Sonamura) and ten monitoring (SANDRP's transcription of CWC, 2018, as reported); State gauges include the Gomati at Udaipur and Amarpur and the Haora at Jahar Bridge (as reported). Only highest, danger and warning levels were read, from transcriptions, with no gauge zero, datum or rating curve [TBC]. Use in the State. Below 25 km² the Rational Method (single elements up to 16 ha) and SWMM or HEC-HMS apply under Clause 3.4, with the design rainfall of Clause 2.3.6, which needs no station; the towns behind embankments are routed with their storage, pumps and sluices against the river level (Commentary to Clause 3.7, rule (e)); and below the Dumbur reservoir the flood is set by the reservoir's releases (Chapter 5).
Table 3E.2 — Worked example outline (layout)
| Step | Content | Clause |
|---|---|---|
| 1 | Catchment area, main stream length, length to centroid and equivalent slope, from survey or DEM | 3.11.4(a) |
| 2 | SUH parameters from Table 3E.1 and the plotted unit hydrograph | 3.11.4(a) |
| 3 | Design storm duration, point and areal 24-hour rainfall with climate factor, time distribution | 3.11.4(a), (b) |
| 4 | Effective rainfall after the design loss rate; convolution with the SUH; base flow added | 3.11.4(a) |
| 5 | 1% AEP peak compared with the HEC-HMS or SWMM peak for the existing natural condition | 3.11.4(c), (d) |
Form 3-1 — Hydrologic Calculation Summary
Supports Clauses 3.4, 3.6, 3.7, 3.8, 3.10–3.13, 3.15–3.17 of Chapter 3.
Draft form — Tripura Stormwater Design Manual, Draft v1.0. One form per submittal. Attach the documents listed in Section H.
A. Project
Table 3F.1 — Form 3-1: project
| Field | Entry |
|---|---|
| A1. Project name and applicant | |
| A2. Location (village or ward, survey numbers, district) | |
| A3. Site area (ha) and number of points of comparison (POCs) | |
| A4. Catchment class: standard (Clause 2.11.2) or flood-sensitive (Clause 2.11.3) | |
| A5. Design Rainfall Sheet reference (Form 2-1) |
B. Method and software (Clauses 3.4, 3.11, 3.12, 3.16)
Table 3F.2 — Form 3-1: method and software
| Field | Entry |
|---|---|
| B1. Purpose of each calculation (conveyance, storage, comparison, catchment study) | |
| B2. Contributing area for each purpose (ha or km²) | |
| B3. Method used and the row of Table 3.1 that permits it | |
| B4. Reason for the choice of method | |
| B5. Software and version; engine and version for packages built on SWMM or HEC (Clause 3.16.1, 3.16.2) | |
| B6. For other software: benchmark results of Annex 3C attached (Table 3C.7) and the 5% comparison of Clause 3.16.2 | |
| B7. Runoff transform (Clause 3.11.1) | |
| B8. Computation interval Δt (h), with 0.133 Tc of the smallest sub-area and the hyetograph time step (Clause 3.11.3(a)) | |
| B9. Storage routing and channel routing methods (Clauses 3.12.1, 3.12.2) | |
| B10. Dynamic-wave routing required? If yes, which condition of Clause 3.12.4 | |
| B11. CWC SUH benchmark required (25–5,000 km², Clause 3.11.4)? Result reference | |
| B12. Continuous simulation required (Clause 3.13.1)? Record used and starting tank levels (Clause 3.13.5) | |
| B13. Calibration required (Clause 3.15.1)? Calibration report reference |
C. Soils and groundwater (Clauses 3.3.3(b), 3.7, 3.10)
Table 3F.3 — Form 3-1: soils and groundwater
| Field | Entry |
|---|---|
| C1. HSG source map, scale and lookup used (Clause 3.7.1, Annex 3A) or NEH Part 630, Ch. 7 assignment (Clause 3.7.2) | |
| C2. Infiltration tests: number, locations, depths, results (Clause 3.7.3) | |
| C3. Seasonal high water table: depth below ground and source (Clause 3.10.2) | |
| C4. Areas within 0.6 m assigned HSG D (Clause 3.10.1) | |
| C5. Disturbed pervious areas and HSG downgrade applied (Clause 3.3.3(b)) |
D. Parameters by sub-area and condition (Clauses 3.3, 3.5, 3.8, 3.9; Clause 3.17 item 4)
Table 3F.4 — Form 3-1: parameters by sub-area and condition
| Sub-area | Condition (pre / post) | Area (ha) | Impervious: roofs / paved / roads (ha) | DCIA (ha) | Disconnected (ha) | HSG | CN, AMC II | CN, AMC III (pervious part) | C and Cf (if Rational) | Tc (min) |
|---|---|---|---|---|---|---|---|---|---|---|
E. Time of concentration worksheet (Clause 3.6)
One worksheet per sub-area and condition.
Table 3F.5 — Form 3-1: time of concentration worksheet
| Segment | Flow type | Surface and n (Table 3.4) | L (m) | S (m/m) | P2 (mm) | V (m/s) | Tt (min) |
|---|---|---|---|---|---|---|---|
| 1 | Sheet | — | |||||
| 2 | Shallow concentrated | — | |||||
| 3 | Channel or pipe | — | |||||
| Tc (not less than 10 min) |
E1. Is the post-development Tc shorter than the pre-development Tc? If not, explain (Clause 3.6.6): ______
F. Rainfall and losses (Clauses 3.8.4, 3.8.5, 3.11.5, 3.12, 3.3.5)
Table 3F.6 — Form 3-1: rainfall, losses and starting levels
| Field | Entry |
|---|---|
| F1. AEPs and durations run; climate factor applied (Chapter 2) | |
| F2. AMC used for each duration (Clause 3.8.4) | |
| F3. Ia ratio for design runs; Ia = 0.05S sensitivity run made (Clause 3.8.5) | |
| F4. Peak rate factor used; if lower than 484, the Annex 3D value and the land it applies to (Clause 3.11.5) | |
| F5. Starting water level of each tank or waterbody, and its basis (Clauses 3.12.5, 3.13.5) | |
| F6. Off-site run-on: land use assumed for conveyance and for the comparison (Clause 3.3.5) | |
| F7. Incidental storage counted? If yes, the authority's acceptance (Clause 3.12.3) |
G. Departures
Table 3F.7 — Form 3-1: departures from Chapter 3
| No. | Clause departed from | Value used in place of the Chapter 3 value | Justification |
|---|---|---|---|
| 1 | |||
| 2 |
H. Attachments (Clause 3.17)
Table 3F.8 — Form 3-1: attachments
| Item | Attached (yes / no / not applicable) | Reference |
|---|---|---|
| H1. Catchment maps, pre- and post-development, with sub-areas, Tc flow paths, POCs and off-site run-on | ||
| H2. HSG map, water-table data and infiltration test results | ||
| H3. Parameter tables (Section D) and Tc worksheets (Section E) | ||
| H4. Design Rainfall Sheet (Form 2-1) and hyetographs | ||
| H5. Hydrograph tables and plots; stage–storage and stage–discharge tables; routed outflows; peak water levels | ||
| H6. Form 3-2 for each POC | ||
| H7. Calibration report (Clause 3.15) | ||
| H8. Native model input and output files (Clause 3.16.4) |
I. Statement by the responsible engineer (Clause 3.17 item 10)
I state that the methods and parameters of Chapter 3 of the Tripura Stormwater Design Manual (Draft v1.0) have been used in this submittal, and that every departure is listed and justified in Section G.
Table 3F.9 — Form 3-1: statement by the responsible engineer
| Field | Entry |
|---|---|
| Name | |
| Qualification and registration number | |
| Organisation | |
| Signature | |
| Date |
Draft form — Tripura Stormwater Design Manual, Draft v1.0.
Form 3-2 — Pre- vs Post-Development Comparison
Supports Clauses 3.8.5, 3.11.5 and 3.14 of Chapter 3.
Draft form — Tripura Stormwater Design Manual, Draft v1.0. One form for each point of comparison (POC). Flows in m³/s, volumes in m³.
A. Point of comparison (Clause 3.14.2)
Table 3F.10 — Form 3-2: point of comparison
| Field | Entry |
|---|---|
| A1. POC identifier and location | |
| A2. Area draining to the POC: site (ha) and off-site run-on (ha) | |
| A3. Off-site run-on passes through site storage? (Clause 3.14.2(c)) | |
| A4. Catchment class: standard (Clause 2.11.2) or flood-sensitive (Clause 2.11.3) | |
| A5. Tailwater applied, including joint cases of Clause 2.12 (Clause 3.14.9(c)) | |
| A6. Flood-sensitive only: largest 10% AEP pre-development peak over all durations, the cap of Clause 2.11.3 (Clause 3.14.7) | |
| A7. Flood-sensitive only: 50% AEP pre-development peak at the pre-development critical duration (Clause 2.11.3) |
B. Peak flows (Clauses 3.14.7–3.14.10)
Limit: standard catchments 0.9 × Q_pre for the same AEP and duration (Clause 3.14.10(a)); flood-sensitive catchments the caps A6 (for 1% AEP) and A7 (for 50% AEP) (Clause 3.14.10(b)).
Table 3F.11 — Form 3-2: peak flows by AEP and duration
| AEP | Duration (h) | AMC | Q_pre | Q_post, uncontrolled | Q_post, routed | Limit | Met? |
|---|---|---|---|---|---|---|---|
| 50% (2-yr) | 1 | II | |||||
| 50% (2-yr) | 2 | II | |||||
| 50% (2-yr) | 3 | II | |||||
| 50% (2-yr) | 6 | II | |||||
| 50% (2-yr) | 12 | III | |||||
| 50% (2-yr) | 24 | III | |||||
| 50% (2-yr) | 48 | III | |||||
| 50% (2-yr) | 72 | III | |||||
| 10% (10-yr) | 1 | II | |||||
| 10% (10-yr) | 2 | II | |||||
| 10% (10-yr) | 3 | II | |||||
| 10% (10-yr) | 6 | II | |||||
| 10% (10-yr) | 12 | III | |||||
| 10% (10-yr) | 24 | III | |||||
| 10% (10-yr) | 48 | III | |||||
| 10% (10-yr) | 72 | III | |||||
| 1% (100-yr) | 1 | II | |||||
| 1% (100-yr) | 2 | II | |||||
| 1% (100-yr) | 3 | II | |||||
| 1% (100-yr) | 6 | II | |||||
| 1% (100-yr) | 12 | III | |||||
| 1% (100-yr) | 24 | III | |||||
| 1% (100-yr) | 48 | III | |||||
| 1% (100-yr) | 72 | III |
C. Volumes and storage (Clauses 3.14.8–3.14.10)
Table 3F.12 — Form 3-2: volumes and storage
| AEP | Governing duration (h) | Runoff volume, pre | Runoff volume, post uncontrolled | Retention volume | Detention storage required | Peak water level in storage (m) |
|---|---|---|---|---|---|---|
| 50% (2-yr) | ||||||
| 10% (10-yr) | ||||||
| 1% (100-yr) |
C1. Governing duration for storage, and the 24, 48 and 72 h results (Clause 3.14.10): ______
D. Sensitivity runs (Clauses 3.8.5, 3.14.11)
Table 3F.13 — Form 3-2: sensitivity runs
| Run | Governing storm (AEP, duration) | Change in Q_post, routed (%) | Change in required storage (%) | Retention volume or WQv governing (Clause 3.8.5(c)) |
|---|---|---|---|---|
| Ia = 0.05S | ||||
| Standard peak rate factor (only where a lower factor is used) | — |
E. Associated checks (Clause 3.14.12)
Table 3F.14 — Form 3-2: associated checks
| Check | Result | Reference in submittal |
|---|---|---|
| Drawdown times (Chapter 4) | ||
| Minimum orifice and trash screen (Chapter 4) | ||
| Emergency spillway (Chapter 4) | ||
| Outfall-closed storage check (Chapter 5) | ||
| Downstream analysis (Chapter 5) |
F. Statement by the responsible engineer
I state that this comparison has been made by the procedure of Clause 3.14, with the same design storms in the pre- and post-development runs, and that no runoff has been diverted from one natural catchment to another to meet the criterion (Clause 3.14.2(b)).
Table 3F.15 — Form 3-2: statement by the responsible engineer
| Field | Entry |
|---|---|
| Name | |
| Qualification and registration number | |
| Signature | |
| Date |
Draft form — Tripura Stormwater Design Manual, Draft v1.0.