Draft v1.0 prepared by NEER. Not adopted by the Government of Arunachal Pradesh or any authority, local body or community, and has no legal force. About this draft

Chapter 2Design Rainfall and Design Storms


2.1 Purpose and scope

2.1.1 This chapter sets the rainfall inputs for every hydrologic calculation in this Manual: drain and inlet sizing (Chapter 6), retention and detention sizing (Chapter 4), downstream and tailwater analysis (Chapter 5), and waterbody and tank works (Chapter 7).

2.1.2 It specifies:

  • (a) the approved sources of design rainfall depth and intensity;
  • (b) how depths are converted between durations, between point and area, and from present to future climate;
  • (c) how design storms (hyetographs) are constructed; and
  • (d) the storms that must be applied to pre- and post-development conditions.

2.1.3 This chapter applies throughout Arunachal Pradesh. Where the Itanagar Municipal Corporation, the Pasighat Municipal Council, a Local Planning Authority or the Authority under the bye-laws has adopted a stricter rainfall standard under Chapter 1, the stricter standard governs.

Commentary. Most past drainage failures in Arunachal Pradesh trace to the rainfall input, not the hydraulics. Arunachal Pradesh shows how. No design storm was found for any town's drains in the State: the master plan of the Itanagar Capital Region proposes a new drainage network designed on the "topography of the region and flow gradient", with no design storm, return period or runoff coefficient, and the expression of interest for the capital's drainage master plan (2017) states no return period. The published sources that seem to fill the gap do not. The CWC report for subzone 2(a) covers almost the whole State on paper but draws its isopluvials only along the foothills, so every hill town lies in blank map space; at the capital its plate reads about 200 mm at 50 years, one contour below the only frequency analysis of a gauge in the capital region, NERIST's at Doimukh (Dabral et al., 2016); and its 1-hour ratio of 0.26 against the 0.48 of the 2(b) report across the Lohit gives two neighbouring towns hours that differ by nearly half for the same day. IMD Das et al. (2022) has no Arunachal Pradesh panel, and NIH-DHAARA gives the foothill towns 1.7 to 2.4 times the plates (Clause 2.3.6). The station figures conflict: IMD's Pasighat record, 652.2 mm on 5 October 1988, is 1.37 times the station's next-highest day, of the same year; Ziro's annual maximum is a February day; the master plan gives Itanagar "2289 mm" a year with no source, against 3,942.44 mm in a CGWB summary; and NERIST's Doimukh normal is 3,531.8 mm against 3,251.67 mm in the same CGWB summary (IMD, Extremes; master plan; Dabral et al., 2016; CGWB, as summarised). Fixing one transparent source and method for the whole state is the main purpose of this chapter.


2.2 Definitions

Term Meaning in this Manual
Annual exceedance probability (AEP) Probability that a given rainfall depth is equalled or exceeded in any one year. A 1% AEP storm is the "100-year" storm. Both forms are used here: T-year = 1/AEP.
IDF / DDF Intensity–duration–frequency and depth–duration–frequency relationships for a location.
Point rainfall Rainfall at a single location, as measured by a rain gauge.
Design storm A hyetograph (rainfall depth versus time) of stated AEP, duration and temporal pattern.
Critical duration The storm duration that produces the largest peak flow, water level or storage requirement for the element being designed.
Areal reduction factor (ARF) Ratio of catchment-average rainfall to point rainfall for the same AEP and duration.
Monsoon season (as used in this Manual) 1 April to 31 October. In this Manual "the monsoon" and "the monsoon season" mean this wet season, which takes in the pre-monsoon months of April and May as well as the south-west monsoon; it is the Manual's season, not IMD's, and IMD's south-west monsoon does not begin in April. IMD's normal date of onset of the south-west monsoon at Itanagar is 5 June (4 June in the older normals), and its normal date of withdrawal is 14 October, unchanged (IMD, 2020, as summarised); no Pasighat date was found. The season begins on 1 April for three reasons. The pre-monsoon months are wet: at Doimukh April brings 227.7 mm, May 505.9 mm and June, the wettest month, 762.8 mm, and the pre-monsoon months of March to May 846.5 mm, 24.0% of a year of 3,531.8 mm (NERIST series, via Dabral et al., 2016, citing Dabral et al., 2006); over the State, March to May bring 23.4% of 2,818 mm (State Action Plan on Climate Change, IMD gridded data 1971–2005), and "The state receives rainfall over a period of 8 to 9 months excepting in winter" (the same plan); in West Kameng the "rainy season starts from April and continues up to November" (CGWB). The east has large April and May falls: Hayuliang 278.5 mm on 24 April 1980, Pasighat 234.4 mm on 29 May 1948 and Tezu 181.4 mm on 21 May 1978, with Tezu's April 2010 total 1,087.9 mm and Hayuliang's April 1975 total 1,367.0 mm (IMD, Extremes). And the damaging pre-monsoon events cluster in the last ten days of May: the remnants of Cyclone Remal on 28–29 May 2024 (Bomdila 190 mm, Miao 120 mm, Namsai 70 mm in 24 hours; IMD bulletin, as summarised), the landslide that swept a vehicle off NH-13 between Bana and Seppa on 30 May 2025, killing seven, and the Pare dam's release of 1,310 m³/s on 31 May 2025 (as reported). The deadline of 31 March (Chapter 10) falls before the April storms, and the mid-season clearance of 15 May before the late-May cluster. Annual normals conflict, and this Manual chooses none: Itanagar 3,942.44 mm (1993–2002; CGWB, as summarised) and "2289 mm" (master plan of the Itanagar Capital Region, no source given); Doimukh 3,531.8 mm (NERIST) and 3,251.67 mm (CGWB, as summarised); Papum Pare district 3,200 mm, East Siang 2,910.18 mm, Lohit 5,179 mm, Changlang 2,913.8 mm (3,800–4,866 mm in parts), West Kameng 1,607 mm and Tawang about 1,600 mm (CGWB); the State 2,818 mm, with "1000 mm in the higher elevations and 5750 mm in the foot hill areas" (State Action Plan on Climate Change). Snow falls in winter on the high ranges: "Higher regions experience snow fall during winter" (the same plan), and Tawang has "occasional rainfall/snowfall during winter" (CGWB). Pasighat's wettest month on record is July 1948, with 3,386.5 mm (IMD, Extremes). The antecedent moisture rule of Clause 2.11.4 and the standby period of Chapter 10 refer to this season.
Storms outside the season Large falls come after the season in the east, and some in winter. In October, about when the south-west monsoon withdraws, Hayuliang recorded 280.0 mm on 3 October 1979 and Tezu 222.0 mm on 4 October 1979, Pasighat's October monthly record is 1,207.9 mm (1979), and Pasighat's 24-hour record of 652.2 mm fell on 5 October 1988 (IMD, Extremes) [U] (Clause 2.3.6(h)); these fall inside the season, which runs to 31 October, but after IMD's withdrawal. In winter Pasighat recorded 137.6 mm on 4 February 1961 and Hayuliang 122.6 mm on 16 February 1973; Ziro's annual record, 150.7 mm on 4 February 1974, is a suspect value [U] (IMD, Extremes). Doimukh's November to February total is 142.68 mm, 4.0% of its year (NERIST, via Dabral et al., 2016). The winter is close to dry below the snow, and December to February is this Manual's works window. Design statistics use annual maxima from all months, no works deadline or operating rule shall assume that heavy rain is confined to June–September, and the works calendar of Chapter 10 keeps a mid-season clearance by 15 May, standby to 31 October and a post-season clearance by 15 November for this reason, with a snowmelt clearance by 30 April where snow lies.
Climate factor (CF) Multiplier applied to present-day design depths to represent the design-life climate.
Approved source A rainfall source listed in Clause 2.3.

2.3 Approved sources of design rainfall

2.3.1 Primary source. Design rainfall depths and intensities shall be taken from the National Institute of Hydrology, Roorkee NIH-DHAARA platform (Design Hydrology and Advanced Rainfall Analysis, nihdhaara.in). Use its IDF / frequency tools for the site's coordinates, for each duration and AEP required by Clause 2.4. In Arunachal Pradesh this clause is suspended until Annex 2A is published: Clause 2.3.6 sets the interim source, and NIH-DHAARA enters it only for the shapes of Clause 2.3.6(d), (e) and (f) and for comparison under (m); it is never a design value in the State.

2.3.2 Station IDF. A station-specific IDF relationship may be used in place of 2.3.1 only if all of the following hold:

  • (a) it is derived from at least 30 years of recording-gauge (hourly or finer) data;
  • (b) it has been published or approved by IMD, the State Hydrology Authority or the approving authority; and
  • (c) the gauge is within 10 km of the site, with no major change of terrain or coastal exposure in between.

Where a station IDF is used, the design value shall be the greater of the station value and the NIH-DHAARA value.

2.3.3 Cross-checks (mandatory, not alternatives). The designer shall report, but need not adopt, the following values for comparison:

  • (a) the IMD isopluvial / IDF values of Das et al. (2022), MAUSAM 73(4), for durations of 1–24 h;
  • (b) for catchments of 25–5,000 km², the 24-hour point rainfall from the CWC Flood Estimation Report for subzone 2(a) (North Brahmaputra), which covers the State north and west of the Lohit (sub-areas AR-A, AR-A1, AR-B, AR-D and AR-E of Annex 2A) but draws its isopluvials only along the foothills, or 2(b) (South Brahmaputra), which covers the south-east (sub-areas AR-C and AR-C1), other than snow-fed and glaciated catchments, to which neither report applies; in the middle hills and high ranges (AR-D and AR-E), which lie inside subzone 2(a) but beyond its last contour, the 2(a) report's unit hydrograph and areal reduction curves are used as a check, and no CWC point rainfall exists there for the cross-check of Clause 2.3.3(b), as applicable.

Where the design value is lower than the CWC subzone 2(a) (North Brahmaputra) or 2(b) (South Brahmaputra) plate, where it draws a contour at the site (the middle hills and high ranges of AR-D and AR-E, inside subzone 2(a) but beyond its last contour, take the floors of Clause 2.3.6(c)(iii) instead) value for the same AEP, the CWC value shall be adopted as a floor.

2.3.4 Not permitted. None of the following shall be used as a design rainfall source:

  • (a) generalised all-India IDF formulae (for example Kothyari & Garde, 1992);
  • (b) rainfall values that cite no source, including vendor or web-calculator tables;
  • (c) single-event maxima; or
  • (d) design intensities carried forward from a previous project without a stated AEP.

1. Station IDF (none yet) ≥25 yr SRRG/AWS, ≤10 km, same sub-area, not across a ridge or the foot of the hills (a) Otherwise, by sub-area of Annex 2A AR-A capital region (c)(ii) capital-region table (NERIST Doimukh, 265 / 290 mm); plate, NIH-DHAARA flagged AR-A1, AR-B, AR-C, AR-C1 (c)(i) 2(a) or 2(b) plate (higher where both), with floors (AR-A1 ≥ AR-A; AR-C1 ≥ 240 / 280) AR-D, AR-E hills (c)(iii) no contour: floors 280 / 320 and 240 / 280 mm (Ziro 320 / 400 mm where the lines reach) Durations 1–24 h (f), before (h) 2(b) ratios on the Noa-Dihing plain; Arunachal interim ratios elsewhere Take the greater per AEP and duration (record floor (h); short-storm floors (g)) IMD Pasighat, Tezu maxima (d), (e) until obtained: 2–25 yr = 2% × 0.42–0.89; 72 h = 24 h × 1.70–2.05 (NIH-DHAARA shape) 24-h record check (h) ≤25 km, two domains; Pasighat 652.2 mm until IMD confirms; Tezu 338.4 mm Short-storm floors (g) 1, 3 and 6 h, in the foothills and plain (AR-A, AR-A1, AR-B, AR-C); none in the hills NIH-DHAARA (m) comparison only; shapes for (d), (e), (f) IMD Das (2022) no Arunachal panel: not used (n) Snow-fed, glaciated (i) site-specific; outburst screening on the main stems and below glacial lakes report Adjustments, in order 1. Fixed-interval → true-interval (Cl. 2.6.3) 2. Grid → point, if grid values (Cl. 2.7.1) 3. Areal reduction, >10 km² only (Cl. 2.7.3) 4. Climate factor 1.20 / 1.10, after (h) (Cl. 2.8) → Design depth → hyetograph (Cl. 2.9) Arunachal Pradesh (Cl. 2.3.6): no station IDF yet; NERIST table in AR-A; plates with floors in AR-A1, AR-B, AR-C, AR-C1; floors in AR-D, AR-E.

Figure 2.1 — Design rainfall source hierarchy and adjustment sequence. Original drawing for this Manual.

2.3.5 Version control. Every submittal shall record the source, its version or access date, the coordinates queried, and the values extracted (Clause 2.13).

2.3.6 Interim source in Arunachal Pradesh. Until Annex 2A is published and confirms NIH-DHAARA, or an approved station IDF, for a zone, Clause 2.3.1 does not apply in Arunachal Pradesh, and design rainfall shall be taken as follows:

  • (a) Station IDF. Where a station IDF fitted to a checked IMD recording-gauge (SRRG) or automatic weather station record of at least 25 years has been published in Annex 2B, it governs, within 10 km of the station and in the same sub-area of Annex 2A, for the durations and AEPs it covers, in place of (f), and subject to (g) and (h); the comparison of Clause 2.3.2 is then made with the 24-hour and longer depths of (c) to (e) and (h). A record is checked when its annual totals and annual maxima have been compared with the IMD normals and station extremes for the station, and every year that disagrees has been explained or removed. An IDF derived from daily data by the one-third rule (Clause 2.6.4) or by any other fixed ratio is not a station IDF. In Arunachal Pradesh Clause 2.3.2(a) is read with 25 years in place of 30, as in the mountain editions of this series, and the gauge shall not be separated from the site by a ridge or by the foot of the hills (set by this Manual, because the State's rain changes over short distances between the plain, the foothills and the ranges: in the 24 hours to 29 May 2024 Bomdila recorded 190 mm, Miao 120 mm and Namsai 70 mm (IMD bulletin, as summarised), and the annual normal is about 1,600 mm at Tawang against 3,200 mm in Papum Pare district (CGWB)). No IDF has yet been published in Annex 2B. No IMD hourly or recording-gauge maximum for any Arunachal Pradesh station, and no IDF with published constants from NERIST, NIT Arunachal or Rajiv Gandhi University, was found for this Manual; NERIST's daily series at Doimukh enters through (c)(ii), not here, and Dabral's depth–duration–frequency paper on Doimukh (Indian Journal of Hill Farming 32(1)) was not obtained [TBC]. The first data requests of this Manual are, in order: (1) from the Meteorological Centre Itanagar, its station series and the archive, since installation, of its automatic weather stations and automatic rain gauges, with annual maxima for 15 minutes to 72 hours at Itanagar, Naharlagun, Pasighat, Ziro, Aalo, Tawang, Bomdila, Tezu and Roing, the best route to an Arunachal Pradesh IDF; (2) IMD's confirmation or withdrawal of Pasighat's 652.2 mm of 5 October 1988 (h), and its ruling on the record set of Ziro; (3) from NERIST, the Doimukh daily series extended past 2012, any hourly record, and the depth–duration–frequency paper above; and (4) the daily annual maxima to 2026 of Pasighat (A) (IMD 42220) and Tezu (IMD 01203), for (d).

  • (b) Reports, zones and sub-areas. Two CWC reports cover the State, and neither covers it in full. Subzone 2(a), North Brahmaputra (Design Office Report No. NB/18/1991, placed before the Flood Estimation Planning and Coordination Committee at its 49th meeting, 24–25 October 1990) covers zones AR-Z1, AR-Z2 and AR-Z4: its text puts the subzone "between 88° and 97°-20′ longitudes (East) and 26° and 29°-25′ latitudes (North)", "mostly bounded by international boundaries", and names "Itanagar … and Anini in Arunachal Pradesh" among its important towns (CWC, 2(a)). Its isopluvials stop at the foothills, about Itanagar, Ziro, Likabali, Roing and Tezu; north of them the plates are blank, and the base map there is schematic, with river courses and towns such as "Yomtam", "Ningguing", "Anini" and "Chirangla" placed approximately (CWC, 2(a), Plates 8–10; NEER reading). The plates shall not be read north of the last contour. Subzone 2(b), South Brahmaputra (Design Office Report No. SB-2(b)/R-4/44/99, March 2000) covers zone AR-Z3; the 2(a)/2(b) boundary leaves the Lohit at about Tezu and runs east-south-east to the Myanmar border, and the 2(b) contours also extend north of the Lohit to Pasighat, Roing and Tezu, overlapping 2(a), with the two disagreeing there by about one contour, 2(a) usually higher (CWC, 2(b), Plates 8–10; NEER reading of the plates, about 0.03–0.1°). The Western Himalayas report, zone 7, covers 73° to 81° E and does not apply. Neither report mentions snow or glaciers for these ranges, and neither unit hydrograph rests on an Arunachal Pradesh catchment: all the gauged catchments of the 2(a) report are railway bridges on the plains of the states the subzone covers (NEER reading). Where the core refers to the CWC report in sub-areas AR-D and AR-E, which lie inside subzone 2(a) but beyond its last contour, the substitutes are (set by this Manual): for areal reduction (Clause 2.7.3), the ARF curves of the 2(a) report; for rural rivers of 25–5,000 km² below the snow, a site study, with the 2(a) unit hydrograph used only as a check; and for the cross-check of Clause 2.3.3(b), none, because no CWC point rainfall exists there. In snow-fed and glaciated catchments neither report applies (i). The rainfall zone and sub-area of the site are those of Annex 2A: zone AR-Z1 Western foothills, with sub-areas AR-A Itanagar capital region (Itanagar–Naharlagun–Nirjuli–Doimukh–Banderdewa) and AR-A1 Western foothills (Bhalukpong–Seijosa–Kimin–Yazali); zone AR-Z2 Eastern foothills, with sub-area AR-B Siang–Dibang–Lohit foothills (Pasighat–Ruksin–Likabali–Roing–Tezu); zone AR-Z3 South-east, with sub-areas AR-C Noa-Dihing plain (Namsai–Chowkham–Bordumsa–Miao) and AR-C1 Patkai hills (Changlang–Jairampur–Deomali–Khonsa–Longding); and zone AR-Z4 Hills and high ranges, with sub-areas AR-D Middle hills (Ziro–Daporijo–Aalo–Seppa–Basar–Yingkiong) and AR-E High ranges (Tawang–Bomdila–Dirang–Mechuka–Anini–Hayuliang). AR-Z1 is subzone 2(a), contoured; AR-Z2 is subzone 2(a) at its edge, which the 2(b) contours also reach; AR-Z3 is subzone 2(b); and AR-Z4 is subzone 2(a) beyond its last contour. They fix the source of (c), the factors of (d) and (e), the ratios of (f), the floors of (g), the bounds of the check of (h) and the screening of (i). A catchment that crosses the line between two zones or two sub-areas of Annex 2A takes, at every duration, the higher value of the two (set by this Manual). The town lists of Annex 2A are a guide; their boundaries, which follow the watersheds, the foot of the hills and district lines, are to be confirmed [TBC], and the district names follow the list of 2024 as reported, not verified. Where a town sits on a zone line, as Yazali, Seijosa, Likabali, Jairampur, Deomali, Miao, Tuting and Hayuliang do, the site's coordinates decide, and the higher value governs [TBC].

  • (c) 24-hour depth, 2% and 1% AEP (50- and 100-yr). Where this clause reads a plate, the 24-hour point value at the site is read from the 50- and 100-year isopluvial plates (Plates 9 and 10) of the report of the site's subzone, whatever the catchment area, as follows (all set by this Manual): where the site lies between two contours, the higher contour value is used; where it lies on a contour, the higher of the two contours either side; where it lies at the open end of a line, that line's value, with no step; where it lies inside a closed contour with no higher contour within it, that contour plus one contour interval (a cell labelled ">" that is open only towards the blank map is read as closed); where the 2(a) and the 2(b) plates both draw contours at the site, the higher reading; and where the Plate 10 reading does not exceed the Plate 9 reading, the 1% AEP depth is the 2% AEP depth plus one contour interval, 40 mm. The open-end and two-plate rules are set for this sector because the 2(a) lines end at the foothills and the two reports overlap north of the Lohit. The contours in this sector are 180, 200, 240, 280, 320, 360, 400, 440 and 480 mm. Plates are read by the coordinates of the site, from each plate's own graticule, not by the town labels or by markers carried from another plate, and each reading is recorded on Form 2-1 with the contours on either side. By sub-area:

    • (i) AR-A1, AR-B, AR-C and AR-C1: the plates. For orientation only, read by eye to about one contour (low confidence; NEER reading of the plates), the readings at 2% / 1% AEP are: in AR-A1, Bhalukpong 240 / 280 mm and Kimin 240 / 280 mm, at the open ends of the 240 and 280 lines (Seijosa and Yazali were not read [TBC]); in AR-B, Likabali 440 / 520 mm, in the ">400" and ">480" cells; Pasighat 320 / 400 mm, where the 2(a) plates are blank and the 2(b) plates place it at the open ends of their 320 and 400 lines; Roing 320 / 400 mm, at the ends of the 2(a) lines (2(b) 280 / 320 mm); and Tezu 280 / 320 mm (2(a); 2(b) 240 / 280 mm); in AR-C, Namsai 280 / 320 mm, between the 240 and 280 lines of 2(b) on both plates, so that the 1% AEP depth is the 2% AEP depth plus 40 mm, and Miao 240 / 280 mm; and in AR-C1, Jairampur 240 / 280 mm, Changlang and Deomali 200 / 240 mm, in a closed "<200" pocket, Khonsa 240 / 280 mm, on its southern edge, and Longding 240 / 280 mm (CWC, 2(a) and 2(b), Plates 9 and 10). Across the Longding border the adjoining Nagaland edition reads one contour higher; the plate governs on each side. Where the Gumbel estimate of (d) for the station of the site is higher for the same AEP, it governs; the 24-hour depth is then checked under (h). Two floors apply (set by this Manual):

      • AR-A1: not less than the AR-A table of (c)(ii) at every AEP, because the sub-area is the same Siwalik front as the capital region and the only gauge on that front reads about one contour above the plate (c)(ii); at Bhalukpong and Kimin the table therefore governs.
      • AR-C1: not less than 240 mm at 2% AEP and 280 mm at 1% AEP: one contour above the "<200" pocket, Longding's own plate value, and the boundary values of the adjoining Nagaland edition's eastern ranges, so that one storm reads alike across the Patkai. NIH-DHAARA's Khonsa cell (233 mm and 260 mm at 50 and 100 years) and Changlang cell (261 mm and 293 mm) lie within about 10% of the floor, the one part of the State where the platform and the plates agree (NIH-DHAARA; NEER reading).
    • (ii) AR-A: the capital-region table. In AR-A the 24-hour design depths are those of the following table, set by this Manual from the frequency analysis of NERIST's daily gauge at Doimukh (Dabral et al., 2016, Table 8, lognormal, 1-day), multiplied by 1.13, the fixed-interval factor of Clause 2.6.3 for a single interval, and rounded up to 5 mm. The 5-, 10-, 25- and 100-year 1-day values are printed in the paper; the 2- and 50-year values are NEER arithmetic on the published fit:

      AEP (return period) 50% (2-yr) 20% (5-yr) 10% (10-yr) 4% (25-yr) 2% (50-yr) 1% (100-yr)
      1-day depth, NERIST Doimukh (mm) 115.9 (NEER arithmetic) 154.36 179.32 210.39 233.3 (NEER arithmetic) 255.95
      24-hour design depth, AR-A 135 mm 175 mm 205 mm 240 mm 265 mm 290 mm

      The station, not the plate, governs at the capital, for four reasons. The 2(a) plates read Itanagar at about 180, 200 and 240 mm at 25, 50 and 100 years, in an open "<200" cell with no contour north of the town, so they do not constrain the hills behind it (CWC, 2(a), Plates 8–10; NEER reading). The only frequency analysis in the capital region, 25 years (1988–2012) of NERIST's daily gauge at Doimukh (27°08′39″ N, 93°45′05″ E, 118 m), published in a peer-reviewed journal, lies about one contour above the plate at every return period (Dabral et al., 2016). The series' principle is that the design value is the greater of the sources (Clause 2.3.2), with the CWC value as a floor (Clause 2.3.3). And Itanagar lies upslope of the gauge and is not drier: CGWB gives annual normals of 3,942.44 mm at Itanagar and 3,251.67 mm at Doimukh (as summarised), while NERIST gives 3,531.8 mm at Doimukh, a conflict this Manual does not settle. The table applies throughout AR-A, beyond the 10 km of (a), because the sub-area is one valley and its hill rim (set by this Manual). The plate readings and NIH-DHAARA (472 mm and 528 mm at 50 and 100 years in the Itanagar cell, 409 mm and 458 mm in the Naharlagun cell, about 1.5 to 1.8 times the table) are recorded on Form 2-1 and flagged, not used. The table has weaknesses, and this Manual states them: the series is short and daily only; its annual maxima fall after 2008 (62.6–155.7 mm in 2009–2012), which is to be checked against the records of the Meteorological Centre Itanagar (a); its 100-year value extrapolates a 25-year record; and the paper prints "83" for the 100-year 4-day value and both "32" and "132" for the annual number of rainy days, typographical errors (Dabral et al., 2016) [U]. A station fit under (a), once made, replaces the table only where it is higher, until Annex 2A says otherwise. This is the reverse of the plateau and ridge capitals of the adjoining hill editions, where the plate lay above the State's own series: here the gauge lies above the plate, so the gauge governs.

    • (iii) AR-D and AR-E: no contour. In the middle hills and high ranges, inside subzone 2(a) but beyond its last contour, the 24-hour depth shall be not less than 280 mm at 2% AEP and 320 mm at 1% AEP in AR-D, and not less than 240 mm and 280 mm in AR-E, or the 2(a) plate reading where a contour reaches the site and reads higher. At Ziro, at the open ends of the 320 and 400 lines on the edge of the plateau, the plates read 320 / 400 mm (very low confidence; NEER reading), which governs there and is recorded on Form 2-1. No station, plate or study covers these hills. The foothill contours rise northward by a contour every 5–10 km, so a town beyond the last contour can be one or two contours wetter than it (NEER reading of the plates); the interior has rain-shadow valleys, with annual normals of about 1,600 mm at Tawang and 1,607 mm in West Kameng (CGWB) and "1000 mm in the higher elevations and 5750 mm in the foot hill areas" (State Action Plan on Climate Change), but it also has large single days: Hayuliang 280.0 mm on 3 October 1979 (IMD, Extremes) and Bomdila 190 mm on 29 May 2024 (IMD bulletin, as summarised). AR-D's floor is one contour above the western foothills' plate values at Bhalukpong and Kimin and equal to Tezu's; AR-E's equals the western foothills' plate values and, at 1% AEP, Hayuliang's largest recorded day (all set by this Manual). NIH-DHAARA is not a design value here: in the foothills, where it can be checked, it runs at 1.7 to 2.4 times the plates and about 1.5 times the NERIST gauge, so its hill cells (308 mm at Ziro, 288 mm at Daporijo, 351 mm at Seppa, 513 mm at Aalo, 328 mm at Bomdila and 129 mm at Tawang, at 50 years) are a bracket only; Tawang's 129 mm, with 17.4 mm in 1 hour at 50 years, is a snow and rain-shadow cell and not a safe minimum (NIH-DHAARA; NEER reading). The adjoining hill editions used boundary values or NIH-DHAARA where no plate exists; this Manual uses floors and never NIH-DHAARA, because here the platform can be checked in the foothills and fails the check. Annex 2A replaces the floors with station fits.

  • (d) 24-hour depth, 50%, 20%, 10% and 4% AEP (2-, 5-, 10- and 25-yr). The depth is the Gumbel (EV1) estimate from the annual maximum daily rainfall series, of all months, of the IMD station agreed with the Authority, with 30 or more years of daily record, checked as in (a), multiplied by the fixed-interval factor of Clause 2.6.3. The stations are Pasighat (A) (42220) and Tezu (01203), each for sites within 25 km of it in AR-B; no IMD daily series of any other station in the State was found suitable, and neither series has been obtained [TBC]. Until they are (set by this Manual), outside AR-A the 50%, 20%, 10% and 4% AEP depths are the 2% AEP depth of (c), before the check of (h), multiplied by 0.42, 0.61, 0.73 and 0.89, and the 4% AEP depth is not less than the 25-year plate value (Plate 8) read as in (c) where a contour reaches the site. The factors are the upper envelope, rounded up to 0.01, of the growth curves of the fifteen NIH-DHAARA cells queried in the State (the 24-hour depth at each AEP divided by the 50-year depth: 0.362–0.413, 0.566–0.601, 0.702–0.726 and 0.873–0.883) (NIH-DHAARA; NEER arithmetic): they take the platform's shape, not its values, and they are the factors of the adjoining Nagaland edition. At Tezu they give about 118, 171, 204 and 249 mm, above Plate 8's 240 mm. The Plate 8 floor governs at Pasighat, at the open end of the 320 line on Plate 8 as on Plate 9, so that its 4% AEP depth is 320 mm, against 285 mm from the factor (NEER reading); at Likabali the factor governs (392 mm, against 360 mm on Plate 8). In AR-A1 the AR-A table of (c)(ii) is the minimum at every AEP. AR-A uses the table of (c)(ii), whose station curve is steeper than the platform's shape (135 / 265 = 0.51 at 2 years, against 0.42). A day of record excluded under (h) is left out of a station series, and the fit with it is reported beside the fit without it on Form 2-1.

  • (e) 48- and 72-hour depths. The Gumbel estimate from the annual maximum 2-day and 3-day rainfall series of the same IMD station, with the fixed-interval factors of Clause 2.6.3, once obtained [TBC], and not less than the 24-hour depth for the same AEP as checked under (h). Until then (set by this Manual), the 72-hour depth is the 24-hour depth after the check of (h) multiplied by 2.05 in AR-A and AR-A1, 1.95 in AR-B, 1.70 in AR-C, 1.75 in AR-C1, 1.90 in AR-D and 1.80 in AR-E, and the 48-hour depth is interpolated between the 24- and 72-hour depths on logarithmic axes. The factors are the upper envelope, rounded up to 0.05, of the 50-year 72-hour to 24-hour ratios of the NIH-DHAARA cells in each sub-area or zone: Itanagar 2.04, Naharlagun 2.02 and Bhalukpong 1.81; Pasighat 1.91, Roing 1.87 and Tezu 1.71; Namsai 1.70; Ziro 1.82, Daporijo 1.88, Aalo 1.82 and Seppa 1.79; and Tawang 1.79 and Bomdila 1.55 (NIH-DHAARA; NEER arithmetic). AR-C1 takes the 1.75 of the adjoining Nagaland edition's northern ranges, above its own cells (Khonsa 1.57, Changlang 1.47), so that one storm reads alike across the Patkai. NERIST's 3-day to 1-day ratios run from 1.98 at 5 years to 1.70 at 100 years (Dabral et al., 2016, Table 8; NEER arithmetic), below AR-A's 2.05, which is the margin accepted. The multi-day volume matters because the Dikrong below the Pare dam and the Siang and the Lohit respond to week-long rain: in the 2026 season to 20 July the State recorded 173 landslides, 104 floods and 8 flash floods (Department of Disaster Management, as quoted in the press).

  • (f) Durations of 1 to 24 hours. The 24-hour depth of (c) or (d), before the check of (h), multiplied at every AEP by the ratios in Table 2B.1 for the site's sub-area (all set by this Manual):

    • in sub-area AR-C (Noa-Dihing plain), the ratios of the 2(b) report: 0.48 at 1 hour, 0.62 at 3 hours, 0.74 at 6 hours, 0.81 at 9 hours, 0.87 at 12 hours, 0.91 at 15 hours and 0.95 at 18 hours, the 10-year ratios averaged over the six recording gauges of the report (CWC, 2(b), §4.3.2 and Table 4.1, p. 20). They are the set that the Assam edition uses on the plain downstream, so that one storm reads alike across the border. On Namsai's 280 mm they give about 134 mm in 1 hour at 2% AEP, against 92 mm in NIH-DHAARA's Namsai cell. No recording-gauge or automatic weather station ratio for any Arunachal Pradesh station was found [TBC];
    • in every other sub-area, AR-A, AR-A1, AR-B, AR-C1, AR-D and AR-E, the Arunachal Pradesh interim ratios: 0.33 at 1 hour, 0.52 at 2 hours, 0.61 at 3 hours, 0.76 at 6 hours, 0.84 at 9 hours, 0.88 at 12 hours, 0.92 at 15 hours and 0.95 at 18 hours. At each duration they are the upper envelope, rounded up to 0.01, of (i) the 50-year duration to 24-hour ratios of the fifteen Arunachal Pradesh NIH-DHAARA cells, with the 3-, 6-, 9-, 15- and 18-hour values interpolated for each cell on logarithmic axes between the platform's 1-, 2-, 4-, 8-, 12- and 24-hour values (the cells' maxima are 0.288 at 1 hour and 0.476 at 2 hours, at Changlang; 0.578 at 3 hours, at Khonsa; 0.732 at 6 hours; 0.795 at 9 hours; 0.845 at 12 hours; 0.884 at 15 hours; and 0.925 at 18 hours); (ii) the ratios of the 2(a) report, 0.260 at 1 hour, 0.457 at 3 hours, 0.615 at 6 hours, 0.720 at 9 hours, 0.805 at 12 hours, 0.875 at 15 hours and 0.930 at 18 hours, averaged over the frequency analyses of 12 IMD recording gauges (CWC, NB/18/1991, §3.1.2, p. 24); and (iii) the interim ratios of the adjoining Nagaland edition, so that the Patkai hills read alike on both sides (NIH-DHAARA; NEER arithmetic). The envelope equals that edition's set.

    The 2(b) ratios are not used in subzone 2(a) or in the hills: 0.48 at 1 hour is about twice the highest Arunachal Pradesh cell north of the Lohit (0.23, at Ziro) and 1.7 times the highest anywhere in the State (0.29, at Changlang); the only sub-daily values found for Itanagar, 40 mm in 2 hours on 23 June 2024 and 52.0 mm "till 12:30" on 27 June 2024 (as quoted; as summarised), are about 2-year falls; and the North-East hill editions rejected the set on their uplands. The hill set is used in AR-A, AR-A1 and AR-B rather than the 2(a) ratios, which the adjoining edition uses on the north bank across the border, because the cells and the adjoining set exceed the 2(a) ratios at every duration; the floors of (g) keep the short durations at the same values on both sides. The 1-hour ratio of 0.26 suggested in the research for this Manual is not used either, because it lies below the cells' maximum and below the adjoining edition's 0.33, and the envelope rule is the series' rule. On the capital's 265 mm the set gives about 87 mm in 1 hour at 2% AEP, against 78 mm in NIH-DHAARA's Itanagar cell, 69 mm with the 2(a) ratio and 127 mm with the 2(b) ratio, before the floor of (g). The ratios apply to the 24-hour depth of (c) and (d) before the check of (h) (the Assam edition's form): the records that qualify under (h) are single long monsoon or autumn days, Pasighat's 652.2 mm in October and Tezu's 338.4 mm in July, which carry no information on the hour; the ratio applied to Pasighat's record would give about 215 mm in 1 hour, twice the 1% AEP floor of (g) and more than twice the largest hour on the valley's recording-gauge record. The adjoining Nagaland edition applies its ratios after its check, because its one qualifying record lies one contour from its plate; here the qualifying records exceed the plates by up to 1.6 times. Between the tabulated durations the ratio is interpolated on logarithmic axes; the 2-hour ratio of 2(b), which the report does not give, is interpolated in the same way.

  • (g) Short storms. In sub-areas AR-A, AR-A1, AR-B and AR-C, the foothills and the plain on the edge of the Brahmaputra valley, the 1-, 3- and 6-hour depths for the 10% AEP (10-yr) and rarer shall be not less than the following (set by this Manual), the short-storm floors of the adjoining Assam edition:

    Duration 10% (10-yr) 4% (25-yr) 2% (50-yr) 1% (100-yr)
    1 hour 70 mm 85 mm 95 mm 105 mm
    3 hours 120 mm 145 mm 165 mm 185 mm
    6 hours 130 mm 160 mm 180 mm 200 mm

    The reasons are that that edition applies these floors on the north bank and the upper plain directly across the border from Banderdewa, Bhalukpong and Namsai, so that one storm reads alike on both sides; that they come from the largest falls on the valley's recording-gauge record (CWC, 2(b), Annex 4.2); and that NIH-DHAARA's 50-year 1-hour depths in the foothill cells, 78–98 mm, bracket the 95 mm value (NIH-DHAARA). They bind at 1 hour in AR-A and AR-A1 at every AEP and at 3 hours at 2% and 1% AEP (at 2% AEP, 87 mm becomes 95 mm and 162 mm becomes 165 mm), and at 1 hour at Tezu at 10%, 4% and 2% AEP; they do not bind at 6 hours anywhere. No floor is set in AR-C1, AR-D and AR-E, as in the adjoining Nagaland edition's hills, because no hill recording gauge exists to base one on and the hill ratios of (f) are already the upper envelope of every cell, of the 2(a) ratios and of the adjoining set. The 2-hour depth shall be not less than the value interpolated on logarithmic axes between the 1-hour and 3-hour depths for the same AEP. Where a station fit later replaces (f), its 1-hour ratio for every AEP shall be not less than 0.33, or 0.48 in AR-C, until Annex 2B is published (set by this Manual). The depths of (f) and the floors are present-day, true-interval values: the fixed-interval factor of Clause 2.6.3 is not applied to plate products or to the floors, and the climate factor of Clause 2.8 is applied to them.

  • (h) 24-hour record check, bounded by domain. The 1% AEP (100-yr) 24-hour depth of (c) or (d) shall be not less than the highest qualifying 24-hour rainfall recorded at any station within 25 km of the site and in the same domain, where that record is higher; the record is used as printed, without the fixed-interval factor, and is treated as a 1% AEP depth; and the 2% AEP (50-yr) 24-hour depth is then not less than the record less one contour interval of the plates, 40 mm (all set by this Manual, in the form of the other North-East editions). The domains are two: the foothills (AR-Z1, AR-Z2 and AR-C, with the plains across the border within 25 km of a site) and the hills (AR-C1 and AR-Z4); a record never counts across the foot of the hills (set by this Manual). A record qualifies only when it is printed by IMD (in Extremes of Temperature and Rainfall for Indian Stations, a climatological summary, a monthly or seasonal climate summary, a later IMD table or an IMD press release that names the gauge and the day); the number of years of data at its gauge is confirmed by an IMD table as at least 20; it was made in 1901 or later; it falls in a month in which a fall of that size is plausible for the station; the location of its gauge is known; and it is not contradicted by another IMD table for the same gauge. A record that fails any test is excluded until IMD confirms what it lacks (set by this Manual). Distances are to be measured from IMD's station coordinates, which were not found [TBC]; the distances below are from the approximate town coordinates used in the research for this Manual (NEER arithmetic). The outcomes at present are:

    • Pasighat (A) (42220), 652.2 mm on 5 October 1988 (IMD, Extremes, rainfall data 1916–2012), qualifies, with a flag. IMD prints it in its monthly table for the station (October, p. M21) and in its annual and seasonal (post-monsoon) tables, so no IMD table contradicts it, and October is a plausible month (Hayuliang 280.0 mm and Tezu 222.0 mm on 3–4 October 1979). It is suspect: it is 1.37 times the station's next-highest day, 476.7 mm on 22 August 1988, in the same year; 1.40 times the only Arunachal Pradesh value in Table 7 of the 2(a) report, 467.0 mm at "Passighat" on 11 July 1948 (467.9 mm in IMD's table for the same day, a conflict of 0.9 mm); it falls in an October whose total is not the October record (1,207.9 mm, 1979); and it is later than the report's data (IMD, Extremes; CWC, 2(a), Table 7; NEER arithmetic) [U]. It sets the 1% AEP 24-hour depth at not less than 652.2 mm and the 2% AEP depth at not less than 612.2 mm within 25 km of the gauge in the foothill domain, which takes in the Pasighat town area; which other places lie within 25 km is to be computed from surveyed coordinates [TBC] (Roing, about 50 km, and Tezu, about 80 km, lie outside). This is the treatment the adjoining Nagaland edition gives its capital's suspect record: the record passes every test this series sets, so it is kept until IMD rules on it. IMD's confirmation or withdrawal is the second data request of (a); if IMD withdraws it, the next record governs: 476.7 mm on 22 August 1988, which sets the 1% AEP depth at not less than 476.7 mm and the 2% AEP depth at not less than 436.7 mm, still about 1.2 times the plate. NIH-DHAARA's Pasighat cell (657 mm and 736 mm at 50 and 100 years) agrees with the record; this is not used as support, because the platform gives twice the plates elsewhere in the foothills (m).
    • Tezu (01203), 338.4 mm on 2 July 1974 (IMD, Extremes, rainfall data 1969–2012), qualifies: it sets the 1% AEP depth at not less than 338.4 mm and the 2% AEP depth at not less than 298.4 mm within 25 km of the gauge in the foothill domain, against a plate reading of 280 / 320 mm; Namsai and Roing, each about 40 km away, lie outside.
    • Flags only, recorded on Form 2-1, none qualifying: Hayuliang, 280.0 mm on 3 October 1979 (IMD, Extremes), whose rainfall data cover only 1971–1985, under 20 years, and which lies at the 1% AEP floor of AR-E in any case; Ziro, 150.7 mm on 4 February 1974, excluded [U], because a February day is an implausible annual maximum for the station and every monthly record falls in 1969–1981 although the rainfall period is printed as 1965–2012, which suggests large gaps, and because it lies below every design value in any case (IMD, Extremes); 185 mm at the NERIST gauge at Doimukh (1990), not an IMD gauge (Dabral et al., 2016); and the values reported from IMD bulletins or in the press: Bomdila 190 mm, Miao 120 mm and Namsai 70 mm in the 24 hours to 29 May 2024 (as summarised); Itanagar 40 mm in 2 hours on 23 June 2024 and 52.0 mm "till 12:30" on 27 June 2024 (as quoted; as summarised); Itanagar "100.30 mm rainfall in the last 24 hours" (year unknown, as reported); and 73 mm in 24 hours, mostly in 3 hours, at the Poosa / NEEPCO colony on 24 June 2026 (as reported).
    • Across the border: North Lakhimpur (A) / Lilabari (42309), 261.6 mm on 12 July 1971 (IMD, Extremes), qualifies in the Assam edition and lies below every AR-A and AR-A1 value; no other record from across the border within 25 km of an Arunachal Pradesh site raises its depth (NEER reading [TBC]).

    Until Annex 2A is published, the designer lists on Form 2-1 every record within 25 km of the site, with its domain and the tests it passes or fails. The check stops at 24 hours. It raises the 24-hour depth and, through (e), the 48- and 72-hour depths; it does not raise the 1- to 18-hour depths, which (f) takes from the depth before the check, because the records are daily totals and no hourly record of any of them exists.

  • (i) Hazard-first sites, snow-fed catchments and outburst screening. No drain is sized to carry a slide, a debris flow or an outburst, so siting, setbacks and floor levels govern on: landslide ground on Siwalik sandstone, shale and boulder beds, colluvium, slope debris and fill, where a landslide at Laptap killed 14 people on 11 July 2017, the Modirijo and Donyi Polo floods of September 2018 brought a landslide from "the dumping area of NH 415", a protection wall fell at Niti Vihar killing 4 (date not found), the Itanagar storms of June and July 2024 brought slides along NH-415, a landslide swept a vehicle off NH-13 between Bana and Seppa on 30 May 2025, and illegal earth cutting along NH-415 was blamed for a mudslide near Donyi Polo airport (all as reported); earth cutting, which the APBBL 2019 refuse above an average slope of 30% (4.39(14)); bhabar fans and avulsion corridors where the rivers leave the hills, at Pasighat, Ruksin, Roing, Tezu, Namsai, Bhalukpong and Banderdewa (NEER reading); the main stems fed from Tibet and from glaciers, the Siang, Dibang, Lohit, Subansiri, Kameng and Tawang Chu, whose stage is set by outbursts, landslide dams and releases, not by local rain: the breach of the Yigong landslide dam in Tibet gave the CWC gauge at Pasighat its highest flood level, 157.54 m on 11 June 2000, 3.58 m above the danger level (CWC data as transcribed by SANDRP, as reported), with "a recorded rise of 5.5 m at the Pasighat gauge, 462 km downstream" (as summarised), and after landslide dams formed in Tibet the Siang ran at 425 NTU at Pasighat on 27 November 2017, with further alerts in October 2018 (as reported); glacial lakes, of which NDMA lists 27 in the State as high-risk, 6 in Tawang, 1 in Kurung Kumey, 1 in Shi Yomi, 16 in Dibang Valley and 3 in Anjaw, while Sanhapo Lake in the Mago Chu basin is reported to have grown from 55.87 ha in 2016 to 87.02 ha in 2026, the outburst of Sangnga Nehgu lake in Tawang is reported without a date, and CWC counted 197 expanding glacial lakes in the State in June 2025 (all as reported; the studies not seen); and release reaches below the Pare, Ranganadi, Kameng and Lower Subansiri projects, and the Dibang project under construction. Snow-fed and glaciated catchments. Neither CWC report covers them; the State Action Plan on Climate Change lists 52 glaciers (66 km²) in the Kameng basin, 91 (146 km²) in the Subansiri basin and 14 (11 km²) in the Dibang basin. In sub-area AR-E, and in any catchment elsewhere with permanent snow or a glacier within it, the design rainfall and design flood are site-specific: the method, data and values are agreed with the Authority and WRD and recorded on Form 2-1, and are not less than the values of (c) to (h) for the rain falling on the part of the catchment below the snow [TBC]. For a local town catchment wholly below the snow and without a glacier, (c) to (h) apply as in AR-E. No design for a site with a glacier, a glacial lake, a landslide dam or a mapped debris fan in the catchment above it, or on the main stem of the Siang, Dibang, Lohit, Subansiri, Kameng or Tawang Chu, is complete without an outburst screening recorded in the drainage report: it identifies the glacial lakes, moraine and landslide dams and debris fans upstream, from NDMA's list of glacial lakes, CWC's glacial-lake monitoring and the hazard maps of APSDMA and the District Disaster Management Authorities where they exist [TBC], and the release reaches below the dams, whose operators' protocols were not found [TBC], and states whether the site lies on their path; where it does, the siting, setback and floor-level rules of Chapters 6 and 7 govern (all set by this Manual).

  • (j) Cloudbursts. IMD calls a fall of 100 mm or more in one hour over a small area a cloudburst (as quoted; no IMD primary document was found for this Manual [TBC]). No design rule is drawn from the term. No measured cloudburst rate exists for the State, and no hourly value for any Arunachal Pradesh gauge was found. On 23 June 2024, when the press reported a cloudburst in Itanagar, the State Disaster Management Authority's secretary said that "As per IMD, the rainfall recorded today was 40 mm between 10:30 am and 12:30 pm" and that IMD "confirmed there was no incident of cloudburst"; 66 houses were inundated in Itanagar and Naharlagun (as reported): a fall of about 2-year size that overwhelmed the drains (NEER reading). A "cloudburst" in Itanagar is also reported for July 2024, about 28 July, with conflicting dateline and publication dates (as reported); the two events are kept apart. The capital's 1% AEP 1-hour depth after (g), 105 mm, reaches the 100 mm mark. What a burst brings to a steep catchment that a design storm does not represent is debris and slide material in its first minutes; there the capacity of inlets, debris racks and culverts to stay open governs more than the conveyance of the drain, and Chapters 6 and 9 size them for it.

  • (k) Durations below 1 hour. No sub-hourly frequency analysis for any station in the State was found in research for this Manual. Until Annex 2B gives one, the ratio of the depth for a duration below 1 hour to the 1-hour design depth is agreed with the Authority, from a published recording-gauge analysis whose source is stated, and recorded on Form 2-1 [TBC]; the average intensity for a duration below 1 hour shall be not less than the 1-hour design intensity for the same AEP (set by this Manual). The time distributions of the 2(a) report (2,207 storms) and of the 2(b) report were not extracted for this Manual [TBC].

  • (l) Order of depths. For the same AEP, no depth shall be less than the depth for a shorter duration.

  • (m) NIH-DHAARA. NIH-DHAARA was queried at fifteen points in the State on 14 November 2026 (IMDAA dataset). It is never a design value in Arunachal Pradesh, nor a floor or a check: its growth shape is used in (d), its 72-hour to 24-hour shape in (e) and its duration-ratio shape in (f), and its present-day values at the site are reported on Form 2-1 beside the interim values in every sub-area, for comparison only, with its bias stated. In the foothills, where it can be checked, it gives 1.7 to 2.4 times the plates and about 1.5 times the NERIST gauge; in the south-east it lies within one contour of the plates; and in the interior it is plausibly low, Tawang's cell not being a safe minimum. Its 50-year 24-hour depths are 472 mm at Itanagar, 409 mm at Naharlagun, 464 mm at Bhalukpong, 657 mm at Pasighat, 726 mm at Roing, 515 mm at Tezu, 461 mm at Namsai, 233 mm at Khonsa, 261 mm at Changlang, 308 mm at Ziro, 288 mm at Daporijo, 513 mm at Aalo, 351 mm at Seppa, 328 mm at Bomdila and 129 mm at Tawang (NIH-DHAARA, queried 14 Nov 2026). Its projected depths are not used under Clause 2.8.4.

  • (n) IMD Das et al. (2022). The paper prints IDF curves for 27 cities and none for any station in Arunachal Pradesh (MAUSAM 73(4), pp. 895–896). It is not cited for any Arunachal Pradesh value, and the cross-check of Clause 2.3.3(a) is recorded on Form 2-1 as not available.

  • (o) Earlier design values. No design storm, return period, IDF or runoff coefficient was found for the drains of any town in the State. The State Action Plan on Climate Change (draft, 2011) budgets "Storm water draining in twenty six urban settlements" at Rs 15,000.0 million with no criteria; the master plan of the Itanagar Capital Region proposes a new drainage network (Maps 28–30) with no design storm, return period or runoff coefficient; the expression of interest of 2017 for a "GIS based Integrated Drainage Master Plan and DPR for Itanagar Capital City" (65 km², horizon 2038) states no return period; the drainage plan reviewed by the Chief Minister in June 2021 and the Itanagar storm-water and seepage project of June 2018 were not seen (as reported); and a SWMM 5.2 study of the drains of Itanagar's C-Sector was seen only as a preprint, its return period not seen (as summarised). Road drains follow IRC practice (Chapter 6). A designer who uses any other value reports it on Form 2-1; the AEPs of Table 2.1 and the depths of this clause apply.

  • (p) Other clauses. Where Clauses 2.3.2, 2.6.1, 2.7.1 and 2.13, Annexes 2A to 2C and Form 2-1 refer to the NIH-DHAARA value, the value under this clause is meant.

Commentary. NIH-DHAARA is a national, publicly accessible product from a Government of India institution, and it can be queried at any point in the State. That makes it a reproducible default that an approving authority can check. NIH-DHAARA's sub-daily values are derived from hourly records, not disaggregated from daily totals. That makes it the only public source suitable for sizing drains, which depend on short-duration intensity. Its values should still be checked against the long IMD daily record at 24 hours and longer (Annex 2A). In Arunachal Pradesh the platform has not met that purpose where it can be tested. It was queried at fifteen points of the State for this Manual. In the foothills, where both the CWC plates and a gauge exist, its cells give 1.7 to 2.4 times the plates and about 1.5 times the frequency analysis of NERIST's gauge at Doimukh, the only one in the capital region; in the south-east they lie within one contour of the plates; and in the interior its Tawang cell, 129 mm at 50 years in 24 hours, lies below a single day of 190 mm at Bomdila. A source that fails the test where it can be tested cannot be adopted where it cannot, so Clause 2.3.6 uses the CWC plates, the NERIST series, the IMD station records and values set by this Manual until Annex 2A has been done, and NIH-DHAARA is never a design value: it lends only its shapes, the growth of depth with return period, the ratio of the 72-hour to the 24-hour depth and the duration ratios, and is reported beside the design values on Form 2-1. IMD Das et al. (2022) is not cited at all, because it has no panel for any station in the State. Arunachal Pradesh follows the other North-East editions, and three things set its interim source apart. First, the CWC plates cover the State on paper but draw contours only along the foothills. The 2(a) report covers every zone except the south-east, which the 2(b) report covers, but its isopluvials stop roughly 10–40 km inside the State, so every hill and high Himalayan town lies inside the subzone in blank map space. Clause 2.3.6(c) therefore reads the plates, with rules for this sector, where they draw contours; carries the capital's gauge across its valley; and sets floors in the middle hills and high ranges, which no station, plate or study covers. Second, the capital's only frequency analysis lies one contour above the plate. NERIST's 25-year daily series at Doimukh gives a 25-year 1-day depth of 210.39 mm, about 240 mm as a 24-hour depth, against about 180 mm on the 25-year plate (Dabral et al., 2016; NEER arithmetic). In the capitals of the adjoining hill editions the plate lay above the State's own series and governed; here the gauge lies above the plate, so the capital-region table of Clause 2.3.6(c)(ii), taken from the gauge, governs, with its weaknesses stated. Third, the State's qualifying records are long single days far above the plates, Pasighat's 652.2 mm in October 1988 and Tezu's 338.4 mm in July 1974, while its short storms are unmeasured: no hourly value from any Arunachal Pradesh gauge was found. So the duration ratios of Clause 2.3.6(f) are applied before the record check of Clause 2.3.6(h), not after it, the hours of the foothills and the plain are held at the short-storm floors of the Brahmaputra valley across the border, and the 2(b) ratios are kept to the Noa-Dihing plain. The interim rules for the more frequent AEPs, the 48- and 72-hour depths, the reading of the plates, the AR-A table, the floors of AR-A1, AR-C1, AR-D and AR-E, the sub-area of each town, the two sets of ratios, the short-storm floors, the bounded record check, the outburst screening and durations below 1 hour are set by this Manual. Several points are unresolved. The plate values were read by eye, to about one contour, and the 2(a)/2(b) boundary and the last 2(a) contours are known only to about 0.03–0.1° [TBC]. Pasighat's 652.2 mm is suspect, and Ziro's record set is excluded [U]. The NERIST series is short and daily, and its later maxima need checking against IMD's records [TBC]. No storm-drain DPR for any town of the State with its design rainfall analysis was found for this Manual [TBC].


2.4 Design return periods (summary)

2.4.1 Design AEPs are set in the chapters for each element. They are summarised here so that the correct rainfall is extracted at the start of design.

Table 2.1 — Design return periods (summary)

Element Design AEP (return period) Check event Chapter
Minor drains: Itanagar, Naharlagun and Pasighat core and high-density areas 10% (10-yr) 1% (100-yr) overland path 6
Minor drains: other Class I urban areas 20% (5-yr) 1% overland path 6
Minor drains: other areas 50% (2-yr) 1% overland path 6
Arterial roads and crossings 2–4% (25–50-yr) next higher AEP 6
Collector / local roads 4% / 10% (25 / 10-yr) 2% / 4% (50 / 25-yr), plus the 1% overland path 6
Major (overland) system 1% (100-yr) — 6
Retention volume Percentile daily rainfall (Clause 2.10) — 4
Detention: standard catchments 50%, 10%, 1% (2, 10, 100-yr) 1% emergency spillway 4
Detention: flood-sensitive catchments Mixed-frequency rule, Clause 2.11 1% 4
Building floor levels 1% + 0.5 m freeboard — 6
Detention emergency spillway 1% with outlet blocked 0.2% (500-yr) where high hazard 4

Commentary. These values exceed the CPHEEO (2019) national advisory minimums of 5-yr (Class I cities) and 2-yr (other areas). CPHEEO allows a State to set higher values. The values are set in Chapters 4 and 6, and the table is reproduced here for convenience.


2.5 Design durations

2.5.1 Conveyance elements (pipes, open drains, inlets, culverts) shall be designed with the intensity for a duration equal to the time of concentration (Tc) of the contributing area (Chapter 3). The minimum duration is 10 minutes.

2.5.2 Storage elements (detention, retention, tanks, pumped sumps) shall be checked for every duration in the set {1, 2, 3, 6, 12, 24, 48, 72 h}. The largest required storage or water level governs. The 24-, 48- and 72-hour storms are mandatory checks at every site, whatever the critical-duration result.

2.5.3 Tidally influenced outfalls. For storage draining to a tidally influenced outfall (Chapter 5), the 48- and 72-hour storms shall also be run with the tailwater boundary of Clause 2.12.

Commentary. Arunachal Pradesh's worst floods have come when days of rain fill the slopes, the reservoirs and the rivers. The Laptap slide of 11 July 2017 came after three days of rain (as reported); at Doimukh the 25-year 3-day depth is 385.01 mm against a 1-day depth of 210.39 mm (Dabral et al., 2016); in late May and early June 2025 the storms that killed seven people on NH-13 on 30 May were followed by a Pare release of 1,310 m³/s on 31 May and by floods in 215 villages of 24 districts by 7 June (as reported); and by 20 July 2026 the season had brought 173 landslides, 104 floods and 8 flash floods (Department of Disaster Management, as quoted in the press). Pasighat's wettest month on record, July 1948, brought 3,386.5 mm (IMD, Extremes). The streams of the hill towns rise within an hour of a burst, but the slides, the slope debris that blocks their culverts, and the rivers and reservoirs that hold the valley-floor outfalls up are set by the whole wet spell, not its peak hour. A rule based only on critical duration, applied to a small site, picks a 1–2 hour storm and misses this failure mode. That is why the long-duration checks are mandatory.


2.6 Sub-daily rainfall

2.6.1 Where NIH-DHAARA or an approved station IDF provides values directly for the required duration, those values shall be used.

2.6.2 Where only daily (24-hour) depths are available for a duration below 24 hours, the sub-daily depth shall be derived using the ratio set of Annex 2B. These are duration-to-24-hour ratios calibrated to Arunachal Pradesh recording gauges. They shall not be lower than the ratios that Clause 2.3.6 sets for the site's sub-area: those of the CWC Flood Estimation Report for subzone 2(b) on the Noa-Dihing plain, as on the Burhidihing plain downstream, and the Arunachal Pradesh interim ratios of Clause 2.3.6(f), the upper envelope of the NIH-DHAARA duration ratios of the Arunachal Pradesh cells, of the ratios of the CWC report for subzone 2(a) and of the interim ratios of the adjoining edition's hills, in every other sub-area: the foothills and hills of subzone 2(a), whether its plates draw a contour there or not, and the Patkai hills of subzone 2(b). The subzone 2(b) ratios are not applied in subzone 2(a) or in the hills; in the foothills and on the plain the short-storm floors of Clause 2.3.6(g) also apply; and IMD Das et al. (2022) prints no panel for any Arunachal Pradesh station.

2.6.3 Fixed-interval adjustment. Depths from fixed observation windows (for example 08:30–08:30 IST daily data, or clock-hour data) shall be converted to sliding-window ("true interval") depths:

  • 1.13 for a single fixed observation interval;
  • 1.04 for 2 intervals;
  • 1.02 for 3–4 intervals.

This adjustment does not apply where the approved source already gives true-interval values.

2.6.4 The empirical relationship P(t) = P(24)·(t/24)^(1/3) shall not be used for design unless Annex 2B confirms it for the zone concerned.

Commentary. The one-third power rule is common in Indian project reports, but no primary IMD source for it was found during research for this Manual. It applies one fixed curve shape everywhere: P(1h)/P(24h) = 0.35, P(3h) = 0.50, P(6h) = 0.63 and P(12h) = 0.79. It cannot represent the difference between a short convective burst and a long monsoon soak, and it tends to understate short-duration depths in convective coastal storms. Annex 2B shall tabulate the NIH-DHAARA ratios P(t)/P(24h) against these values by zone. That comparison shows whether the rule is acceptable anywhere in the State and corrects older daily-based analyses. The fixed-interval factors are the standard WMO (Hershfield) values. The IMD 2022 study applies similar clock-hour to any-hour corrections.


2.7 Point, grid and areal rainfall

2.7.1 Design depths are point values. Where an approved source provides grid-average values (for example 0.25° cells), they shall be converted to point values with the grid-to-point factors in Annex 2C before use.

2.7.2 For catchments ≤ 10 km², ARF = 1.0.

2.7.3 For catchments > 10 km², apply ARF as follows:

  • for 25–5,000 km² in subzone 2(a) (North Brahmaputra), including the middle hills and high ranges beyond its last contour, or 2(b) (South Brahmaputra): use the ARF curves of the applicable CWC Flood Estimation Report;
  • for 10–25 km²: interpolate linearly between ARF = 1.0 at 10 km² and the CWC value at 25 km².

2.7.4 An ARF shall never be applied to storage design for a single development site.

Commentary. Gridded and district-average return levels are much lower than point values. For example, NIH-DHAARA's cell over Itanagar gives 472 mm at 50 years in 24 hours, about 1.8 times the 265 mm that this Manual takes from the NERIST gauge at Doimukh and more than twice the CWC plate there, while its Tawang cell gives 129 mm, below the 190 mm that Bomdila received on a single day in May 2024 (NIH-DHAARA, queried 14 Nov 2026; Dabral et al., 2016; IMD bulletin, as summarised). Reanalysis cells smooth the foothills and the ranges together, and an area average hides the falls at its gauges. Neither error can be corrected without the factors of Annex 2C. Using grid values as point values without correction would make site-level design unsafe.


2.8 Climate factor

2.8.1 Until a statewide future-climate rainfall product is adopted, present-day design depths shall be multiplied by the following interim climate factors:

Table 2.2 — Interim climate factors

Duration Climate factor (CF)
≤ 6 h 1.20
> 6 h to 72 h 1.10

2.8.2 The CF applies to all elements with a design life of more than 25 years. For temporary works (design life ≤ 5 years), CF = 1.0.

2.8.3 The climate factor does not apply to the retention depth (Clause 2.10) or to the water quality volume depth (Chapter 8). Those depths are percentile or frequent-event statistics of everyday rainfall, not AEP design values.

2.8.4 Where NIH-DHAARA, or a product adopted on review under Clause 2.14, provides projected future-climate depths, those depths shall replace the interim factors.

Commentary. CPHEEO (2019) considers a fixed climate factor "not feasible" nationally and recommends trend testing instead. That leaves designers without a usable number. The 1.20 short-duration factor matches the UK value cited by CPHEEO itself. No design uplift factor has been adopted in Arunachal Pradesh, and none was found in any document read for this Manual. The State Action Plan on Climate Change (draft, July 2011) projects annual rainfall 5% to 15% lower in the 2030s, with "decrease in rainfall … projected for all seasons except pre monsoon for 2030s", and 25% to 35% higher by the 2080s, and sets no extreme-rainfall or IDF factor; Down To Earth reports the plan's decrease as "in the 2050s" (as reported), against the "2030s" of the plan's own text, a conflict this Manual does not settle. The observed record is mixed: the plan reports "spatial variability in rainfall trend (increasing as well as decreasing trend)"; a researcher is reported to find declining totals with more frequent high-intensity events (as reported; no paper seen); and the Meteorological Centre Itanagar has said that one season is not enough to establish a trend (as reported). CSTEP's district projections of 2022 are reported to recommend a revision of the State plan (as reported). The case for an uplift rests on the size of recent extremes and on the national practice of this series, not on trend statistics. The factors of Table 2.2, 1.20 up to 6 hours and 1.10 for longer durations, are therefore interim values, not Arunachal Pradesh estimates; as in the other editions of this series they are applied after the record check of Clause 2.3.6(h), and they apply to the short-storm floors of Clause 2.3.6(g). NIH-DHAARA's projected depths are not used (Clause 2.3.6(m)); its climate grids for Itanagar, Pasighat and Tezu are a check still to be made [TBC].


2.9 Temporal patterns (design hyetographs)

2.9.1 Storms up to 24 hours. Use the nested alternating-block method:

  • construct the storm from the same IDF relationship (after the climate factor), at time steps no longer than Tc/3 and no longer than 15 minutes;
  • place the peak block at 50% of the storm duration.

2.9.2 48- and 72-hour storms (monsoon pattern). Construct as follows:

  • (a) The total storm depth equals the design depth for the full duration (48 or 72 h).
  • (b) The final 24 hours contain the 24-hour design depth for the same AEP, distributed by the alternating-block method of 2.9.1.
  • (c) The remaining depth (total minus the 24-hour depth) is spread uniformly over the preceding 24 or 48 hours.

2026-10-31T09:49:37.193022 image/svg+xml Matplotlib v3.9.4, https://matplotlib.org/ 0 6 12 18 24 Time (h) 0 10 20 30 40 50 60 70 80 Rainfall (mm per h) (a) 24-h alternating-block storm 0 12 24 36 48 60 72 Time (h) Remaining 72-h depth, spread uniformly (antecedent rain fills soils, RWH sumps, tanks) 24-h design depth on the final day (alternating block, Clause 2.9.1) (b) 72-h monsoon storm Illustrative — not design values (100-yr 24-h = 350 mm, 72-h = 520 mm, hourly blocks).

Figure 2.2 — (a) 24-hour alternating-block design storm; (b) 72-hour monsoon design storm with the 24-hour design depth on the final day. Illustrative depths only. Original drawing for this Manual. The alternating-block method follows Chow, Maidment & Mays, Applied Hydrology (1988), §14.4.

2.9.3 Other temporal patterns. Huff-type or mass-curve patterns derived from Arunachal Pradesh storms may be used instead of 2.9.1 and 2.9.2 only after they are published in Annex 2D. SCS Type I, IA, II and III distributions shall not be used.

2.9.4 Large catchments. For catchments of 25–5,000 km², the CWC Flood Estimation Report time-distribution curves may be used, and a sensitivity run with 2.9.1 shall be reported.

Commentary. The alternating-block storm embeds every shorter-duration design intensity in one hyetograph. That makes it conservative and consistent across durations. The 72-hour pattern puts the most intense day last. This reproduces the monsoon sequence of Arunachal Pradesh: by the time the largest falls arrive, from June to September after the storms of April and May, the residual soils, slope debris and fill of the Siwalik foothills are saturated, the Pare and Ranganadi reservoirs are releasing, and the Dikrong, the Siang, the Lohit and the Noa-Dihing are already high against the valley-floor outfalls. SCS distributions are excluded because they come from US convective and Gulf storm data and have no basis in Arunachal Pradesh records.


2.10 Retention rainfall depth

2.10.1 The retention design depth is the 24-hour rainfall depth not exceeded on 90% of days with rain (≥ 2.5 mm) in the long-term record, read from the zone value in Annex 2E.

2.10.2 The site must retain on site the runoff from this depth (Chapter 4). Retention earns a detention credit equal to the reduction in required detention storage found by routing with the retention in place (Clause 4.4.6). The credit is not the retained volume subtracted one-for-one.

Commentary. This follows the Kansas City Metro APWA 5600 (2025.01) Required Retention Volume concept and Georgia's 1.0-inch runoff reduction standard. Both are based on percentile storms. A percentile depth is a statistic of everyday rainfall, not an AEP value, so it is computed from the daily record rather than from the frequency curves.


2.11 Design storms for pre- and post-development comparison

2.11.1 Same storm for both scenarios. Pre- and post-development runs shall use the same design storms:

  • same AEP, duration, temporal pattern and climate factor;
  • same antecedent moisture condition (Clause 2.11.4).

The two runs differ only in land surface parameters and Tc.

2.11.2 Standard catchments. For each of the 50%, 10% and 1% AEP storms and each duration in Clause 2.5.2:

Q_post(T) ≤ 0.9 × Q_pre(T)

2.11.3 Flood-sensitive catchments (as listed in Chapter 4: the catchments of the Senki, of the Pachin, of the Dikrong with Papu Nallah, of the NH-415 corridor, of Modirijo and Donyi Polo, of Pasighat on the Siang, of Tezu on the Lohit, of Namsai and Miao on the Noa-Dihing, of Roing on the Dibang, of the Ranganadi at Yazali and of the outburst reaches of Tawang and Dibang Valley, and any catchment notified by the authority). The mixed-frequency rule applies:

Q_post(1% AEP, 100-yr) ≤ Q_pre(10% AEP, 10-yr), and Q_post(50% AEP, 2-yr) ≤ Q_pre(50% AEP, 2-yr),

The post-development peak is checked for each duration in Clause 2.5.2. The caps are taken at the pre-development critical duration. The 10-yr cap is the largest pre-development 10-yr peak over all durations, and the 2-yr cap is the largest pre-development 2-yr peak over all durations. Each cap applies to every post-development duration.

2.11.4 Antecedent moisture. Use AMC III (wet conditions) for every design storm, whatever its duration, from 1 May to 15 October at a site in sub-area AR-A (Itanagar capital region), AR-A1 (Western foothills), AR-C (Noa-Dihing plain) or AR-C1 (Patkai hills) of Annex 2A, from 1 April to 31 October at a site in sub-area AR-B (Siang–Dibang–Lohit foothills), and from 1 June to 15 October at a site in sub-area AR-D (Middle hills) or AR-E (High ranges). Use AMC III for every design storm from 1 April to 31 October, in every sub-area, on land below the 1% AEP flood level of the Dikrong, the Pachin, the Senki, the Siang, the Dibang, the Lohit, the Noa-Dihing or another river, stream or nallah, on the palaeochannels and swampy land of the Pachin and Dikrong flood plains, on the margins of a pond and wherever the seasonal high water table is within 2 m of ground. Use AMC III for every design storm at any time of year in a catchment that drains to a reservoir or its backwater, or to a reach below a dam into which the dam releases water, such as the Dikrong below the Pare dam, the lower Ranganadi below the Ranganadi project, the Kameng below the Bichom and Tenga dams and the Subansiri below the Lower Subansiri dam. At any other site or time, use AMC III for a design storm that follows, or contains, a 5-day rainfall total of more than 53 mm. Use AMC II (average conditions) for every other storm. AMC I is not used for design.

2.11.5 Pre-development condition. Pre-development is defined in Chapter 3: greenfield, open land in good condition for the mapped hydrologic soil group. Existing impervious cover is not counted as pre-development.

Commentary. Matching each site's post-development peak to its own pre-development peak does not protect the catchment. Denver's analysis found that 100% matching at every site still produced 106% of historic peak downstream, which led to the 90% rule. The mixed-frequency rule is stricter. It caps the 100-yr post-development release at what the undeveloped site produced in a 10-yr storm. Malaysia (DID 2008: all ARIs ≤ pre-development 2-yr) is a tropical precedent for this kind of cap. AMC III for long storms reflects that monsoon extremes arrive after weeks of rain. In Arunachal Pradesh the season, the ground and the receiving waters together decide how wet a catchment is. At Doimukh May brings 505.9 mm, two-thirds of June's 762.8 mm, the wettest month (NERIST series, via Dabral et al., 2016), so the foothills are wet before the south-west monsoon arrives; in the Lohit valley April and October bring storms of 180–280 mm in a day (Hayuliang 278.5 mm on 24 April 1980; Hayuliang 280.0 mm and Tezu 222.0 mm on 3–4 October 1979) and Tezu's April 2010 total was 1,087.9 mm (IMD, Extremes). On the valley floors the water table lies 2–4 m below ground before the monsoon and 2–5 m after it in the Dikrong valley (CGWB), and 15 of 27 State stations stood within 2 m of ground in August 2025 (CGWB bulletin, as summarised), so low land is wet from the first storms. The Pare, Ranganadi, Kameng and Lower Subansiri reservoirs are held through the season and release through their gates, so a catchment that drains to one of them, or to the reach below its dam, is wet whenever it is spilling. This Manual therefore uses AMC III for every design storm from 1 May to 15 October in sub-areas AR-A, AR-A1, AR-C and AR-C1, from the wet May of the foothills to IMD's normal withdrawal of the south-west monsoon at Itanagar on 14 October, rounded out (IMD, 2020, as summarised); from 1 April to 31 October in AR-B, for the April and October storms of the Lohit valley; from 1 June to 15 October in AR-D and AR-E, the south-west monsoon from its normal onset at Itanagar on 5 June to its withdrawal, rounded out, because the interior has rain-shadow valleys (Tawang about 1,600 mm a year; CGWB); from 1 April to 31 October in every sub-area on land below the 1% AEP flood level of a river, stream or nallah, on the palaeochannels and swamps of the Pachin and Dikrong flood plains, on pond margins and wherever the seasonal high water table is within 2 m of ground; at any time of year in a catchment that drains to a reservoir, its backwater or a release reach; and otherwise after a 5-day total of more than 53 mm, the NRCS growing-season threshold for AMC III; AMC II otherwise (Clause 2.11.4). The research for this Manual suggested AMC III from May to September in the foothills; this Manual widens it to 15 October because the south-west monsoon withdraws from Itanagar on 14 October in IMD's normals. AMC I is not used, because no part of the State is dry enough during the season to justify it. These are interim choices set by this Manual; no study in the State has yet validated AMC classes against observed runoff.

Illustrative scale of the mixed-frequency rule. The values below are not design values. They assume a 2 ha site in a hillside colony in Itanagar draining to the Senki with 24-h depths of 200 mm (10-yr) and 350 mm (100-yr), SCS-CN runoff with Ia = 0.2S, and CN 70 pre-development and CN 92 post-development:

Table 2.3 — Illustrative scale of the mixed-frequency rule (not design values)

Case Runoff depth Runoff volume (2 ha)
Pre-development, 10-yr 24 h 111 mm 2,210 m³
Post-development, 100-yr 24 h 325 mm 6,500 m³

The post-development 100-yr storm generates about three times the runoff volume of the pre-development 10-yr storm. A peak-rate cap at the pre-development 10-yr level means most of the difference must be stored and released slowly, so storage of the order of 0.2 m³ per m² of site may be needed. For this reason the rule applies only in flood-sensitive catchments (Clause 2.11.3); elsewhere the 0.9 × Q_pre rule of Clause 2.11.2 applies.


2.12 Joint occurrence with tailwater

2.12.1 For outfalls under tidal or river backwater influence, the design rainfall of this chapter shall be combined with the tailwater conditions of Chapter 5 as follows. The more severe case governs.

  • (a) Design rainfall (AEP as required) with a mean high water springs (MHWS) tailwater plus the sea-level allowance.
  • (b) A 10% AEP (10-yr) 48-hour storm with the 1% AEP still-water level (tide plus surge) plus the sea-level allowance.

Arunachal Pradesh has no coast, so no outfall in the State is tidal and cases (a) and (b) do not arise. The tailwater is the stream, nallah, river or reservoir into which a town drains: in the capital region, the Dikrong backing up a nallah when it carries the Pare dam's releases and the Ranganadi project's tailrace; at Pasighat, Tezu and Namsai, a main stem whose stage is set upstream, at Pasighat by outbursts in Tibet; below the dams, a reservoir release; and in the hills, a free outfall to a steep stream. For an outfall under river or reservoir backwater, the site storm is combined with the receiving-water level under Clause 5.8.4, which pairs a design event on one side with a 10-yr event on the other in the same way as case (b), and the river and reservoir levels are those of Clause 5.8.2. CWC's sites in the State give levels for some of these rivers: the Siang at Pasighat, with a warning level of 152.96 m, a danger level of 153.96 m and a highest flood level of 157.54 m on 11 June 2000, the stage of the Yigong outburst, 3.58 m above the danger level; the Noa-Dihing at Namsai, 144.8 m, 145.8 m and 146.6 m (31 August 1974), values that SANDRP says "changed without explanation"; and highest flood levels only at Tezu on the Lohit (192.14 m, 16 July 1996), Yazali on the Ranganadi (623.1 m, 14 June 2008), Miao on the Noa-Dihing (241.57 m, 9 July 2004) and Daporijo on the Subansiri (213.9 m, 15 October 1987) (CWC data as transcribed by SANDRP, as reported). There is no CWC site on the Dibang, on the Senki, the Pachin or the Dikrong in the capital region, or at Bhalukpong. The CWC sites on these rivers downstream of the State, tens of kilometres away, are not tailwater for any Arunachal Pradesh town, and the Assam edition governs those reaches. The Dikrong below Doimukh carries the Pare dam's releases, which peaked at 1,310 m³/s on 31 May 2025, under NEEPCO's monsoon advisories on releases through the radial gates, and the Ranganadi project's tailrace, 160 m³/s against an observed Dikrong flood flow of about 2,500 m³/s in a 1994 study; the 1999 flood is the local benchmark (all as reported). No operator's release protocol or warning threshold, and no spillway capacity, was found [TBC]. In the hills the opposite case occurs: at Yazali a side stream of about 17 km² flooded the Poosa / NEEPCO colony while "the main river stayed in its channel" (as reported). So storage and outfalls are checked with the river low and with it high, and for the outfall-closed condition with the local storm falling before, during or after the river's peak. No document found in research for this Manual sets a design receiving-water level for the outfalls of any town in the State [TBC], and Chapter 5 sets the interim rule. Every level is stated on a named datum, as Chapter 5 requires; no source found states the datum of the CWC levels quoted here [TBC].

Commentary. Arunachal Pradesh has no coast, so no outfall is tidal and there is no storm surge; the coincident load is the level of the rivers, nallahs and reservoirs that receive the town drains. Both kinds of coincidence are on record. In late May 2025 the storms that killed seven people on NH-13 on 30 May were followed by the Pare dam's peak release of 1,310 m³/s into the Dikrong on 31 May, above the outfalls of Doimukh and Naharlagun (as reported). At Pasighat the Siang's highest level, 157.54 m on 11 June 2000, came from the breach of a landslide dam in Tibet, with no local storm behind it (CWC data as transcribed by SANDRP, as reported). The opposite case occurs too: on 24 June (2025 or 2026) a side stream of about 17 km² flooded the Poosa / NEEPCO colony at Yazali while "the main river stayed in its channel" (as reported). These levels give no warning of a local storm that falls while they are high. The river levels quoted for the State are transcriptions of CWC data, not readings of a CWC bulletin, and none states its datum, which is why Chapter 5 requires every level to name its source and datum. Because rainfall and surge share a weather cause (in Arunachal Pradesh, which has no coast, the counterpart of surge is the stage of the rivers and reservoirs that receive the town drains, raised by the same monsoon storms that bring the heaviest rain to the towns: the Pare dam's release peaked at 1,310 m³/s on 31 May 2025, the day after a landslide in the late-May storms swept a vehicle off NH-13 between Bana and Seppa, killing seven (as reported); at Pasighat the Siang's stage is also set by outbursts in Tibet, which no local storm accompanies), they cannot be treated as independent. Case (b) is a simple joint-probability surrogate until a statistical joint analysis is adopted.


2.13 Submittal requirements

Every hydrologic submittal shall include a Design Rainfall Sheet (Form 2-1) stating:

  1. the site coordinates and zone;
  2. the source (Clause 2.3), version or access date, and a screenshot or export of the values extracted;
  3. a depth table for each AEP and duration used, before and after the fixed-interval factor, grid-to-point factor, ARF and climate factor;
  4. the cross-check values of Clause 2.3.3 and the floor check;
  5. the hyetographs used, as a table and a plot, for each design storm; and
  6. the AMC and pre-development definition adopted.

Figure 2.3 shows the steps of this chapter in the order in which the sheet records them.

Figure 2.3 — From design rainfall source to design storm Seven steps in sequence: choose the approved source; set AEPs and durations; point depth for each AEP and duration; grid to point and areal reduction; climate factor; temporal pattern; design storm. A side panel lists what Form 2-1 records, and a second panel shows that the retention depth takes a separate route without the climate factor. From design rainfall source to design storm Steps a designer follows in Chapter 2, with the governing clause (schematic flowchart) 1 Choose the approved source Cl. 2.3 NIH-DHAARA at the site coordinates. Station IDF only with ≥ 30 yr record within 10 km; the greater value governs. Report the IMD (Das et al. 2022) cross-check; CWC subzone value is a floor for 25–5,000 km². 2 Set the AEPs and durations Cl. 2.4–2.5 AEP for each element from Table 2.1. Conveyance: duration = Tc, not less than 10 min. Storage: every duration in {1, 2, 3, 6, 12, 24, 48, 72 h}; 24, 48, 72 h always. 3 Point depth for each AEP and duration Cl. 2.6 Read the depth from the source for each duration. If only daily depths exist, use the Annex 2B ratios (not the one-third rule). Fixed-interval data × 1.13 / 1.04 / 1.02 for 1 / 2 / 3–4 intervals. 4 Grid to point, then areal reduction Cl. 2.7 Grid-average values × grid-to-point factor (Annex 2C). ARF = 1.0 up to 10 km²; CWC curves above 25 km², linear between. No ARF for storage on a single development site. 5 Apply the climate factor Cl. 2.8 × 1.20 for durations ≤ 6 h; × 1.10 for > 6 h to 72 h. CF = 1.0 for temporary works (design life ≤ 5 years). Not applied to the retention depth or the WQv depth. 6 Build the temporal pattern Cl. 2.9 ≤ 24 h: alternating block, peak at 50%, time step ≤ Tc/3 and ≤ 15 min. 48 / 72 h: the 24 h design depth in the final 24 h; the remainder spread uniformly before it. SCS Type I, IA, II and III are not permitted. 7 Design storm (hyetograph) Cl. 2.11–2.12 Same storms for pre- and post-development runs. AMC II for storms ≤ 6 h; AMC III for 12 h and longer. Tidal or backwater outfalls: also run the joint cases of Clause 2.12. Form 2-1 Design Rainfall Sheet (Cl. 2.13) records: 1. Site coordinates and zone 2. Source, version or access date, export 3. Depth table before and after each factor (steps 3–5) 4. Cross-checks and the CWC floor 5. Hyetographs: table and plot (steps 6–7) 6. AMC and pre- development condition Retention depth (separate route) 90th percentile wet-day (≥ 2.5 mm) 24 h depth, zone value from Annex 2E. No climate factor, no hyetograph for sizing the volume. Cl. 2.10, 2.8.3 Schematic flowchart. Clause numbers refer to Chapter 2. The order of steps 3–5 is the order of the columns of the depth table on Form 2-1.

Figure 2.3 — From design rainfall source to design storm: the steps a designer follows (source, AEPs and durations, point depth, grid-to-point and areal reduction, climate factor, temporal pattern, design storm), the clause that governs each step, what Form 2-1 records, and the separate route for the retention depth. Schematic. Original drawing for this Manual.


2.14 Review and update

2.14.1 The approving authority shall review this chapter every 10 years. It shall also review it within 2 years of any event in which recorded rainfall exceeds the 1% AEP 24-hour or 72-hour design depth at two or more approved gauges in the State.

2.14.2 Updates to NIH-DHAARA take effect for new submittals 6 months after release, unless the authority notifies otherwise.


References (chapter)

  • National Institute of Hydrology, Roorkee. NIH-DHAARA: Design Hydrology and Advanced Rainfall Analysis. http://www.nihdhaara.in/
  • Das, S.K. et al. (2022). Isopluvial analysis and intensity–duration–frequency curves for different cities in India. MAUSAM 73(4), 887–898. https://metnet.imd.gov.in/docs/mausamdocs/173412_F.pdf
  • Central Water Commission (1991). Flood Estimation Report for North Brahmaputra Subzone 2(a), Design Office Report No. NB/18/1991 (placed before the FEPCC at its 49th meeting, 24–25 October 1990) (Plates 8, 9 and 10, the 25-, 50- and 100-year maps, read by eye from page images; text on the extent, towns, rivers and rainfall of the subzone; §3.1.2, p. 24, the short-duration ratios; the loss rate; Table 7, the heaviest falls, with the Passighat row). https://cwc.gov.in/regional-flood-estimation-report
  • Central Water Commission (2000). Flood Estimation Report for South Brahmaputra Subzone 2(b) (Revised), Design Office Report No. SB-2(b)/R-4/44/99, March 2000 (Plates 8, 9 and 10, read by eye from page images; §4.3.2 and Table 4.1, p. 20, the short-duration ratios). https://cwc.gov.in/regional-flood-estimation-report
  • Central Water Commission. Flood Estimation Report for the Western Himalayas, zone 7, WH/22/1994 (extent 73°–81° E; cited only to say that it does not reach the State).
  • MoHUA / CPHEEO (2019). Manual on Storm Water Drainage Systems, Part A.
  • India Meteorological Department. Extremes of Temperature and Rainfall for Indian Stations (up to 2012): Pasighat (A) ("Passighat", 42220, rainfall data 1916–2012), Tezu (01203, 1969–2012), Hayuliang (01212, 1971–1985) and Ziro ("Zero", 42312, 1965–2012 as printed), monthly tables pp. M21–M22, the annual and seasonal 24-hour record tables and the station list; North Lakhimpur (A) / Lilabari (42309) for the check of Clause 2.3.6(h). https://imdpune.gov.in/library/public/EXTREMES%20OF%20TEMPERATURE%20and%20RAINFALL%20upto%202012.pdf
  • India Meteorological Department (2020). New Normal Dates of Onset/Progress and Withdrawal of Southwest Monsoon over India (Itanagar; as summarised). https://mausam.imd.gov.in/backend/assets/press_release_pdf/IMD_Press_release_new_onset_and_withdrawal_dates%28Final%29.pdf
  • India Meteorological Department, Meteorological Centre Itanagar. Bulletins and special weather bulletins of 2024 (rain classes; Itanagar 52.0 mm "till 12:30 IST", 27 June 2024; the Remal falls of 29 May 2024) (as summarised; station list and archive not obtained [TBC]).
  • Das, S.K., Srivastava, A.K. & Yadav, B.P. (IMD) (2022). MAUSAM 73(4), 887–898, Figs. 4(i)–(xxvii), pp. 895–896 (no Arunachal Pradesh panel). https://metnet.imd.gov.in/docs/mausamdocs/173412_F.pdf
  • NIH-DHAARA, IDF tool, IMDAA dataset, queried for fifteen points in Arunachal Pradesh on 14 Nov 2026 (tool output). http://117.252.14.251:8080/
  • Dabral, P.P., Kumar, A. & Tana, G. (2016). Determination of surface drainage coefficient – a case study of Doimukh (Arunachal Pradesh), India. Agricultural Engineering International: CIGR Journal 18(4), 1–10 (NERIST meteorological laboratory, Doimukh, 27°08′39″ N, 93°45′05″ E, 118 m; daily rainfall 1988–2012; Tables 1, 4 and 8; infiltration test).
  • Dabral, P.P. Depth–duration–frequency analysis of Doimukh rainfall. Indian Journal of Hill Farming 32(1) (as listed; not obtained [TBC]).
  • Government of Arunachal Pradesh. Arunachal Pradesh State Action Plan on Climate Change (draft, July 2011).
  • Central Ground Water Board, North Eastern Region. Ground Water Information Booklets: Papum Pare, East Siang, Lohit, Changlang, West Kameng and Tawang districts; the North Eastern Region ground-water level bulletin of August 2025 (as summarised).
  • South Asia Network on Dams, Rivers and People (2019). Overview of CWC's flood forecasting sites 2019: North East India (transcriptions of CWC data; secondary source). https://sandrp.in/2019/10/02/overview-of-cwcs-flood-forecasting-sites-2019-north-east-india/
  • Press reports of the storms and floods of July 2017, September 2018, May, June and July 2024, May–June 2025 and June–July 2026, of NEEPCO's release advisories, of the Pare dam's release of 31 May 2025 and of NDMA's glacial-lake list (secondary sources).
  • Chow, V.T., Maidment, D.R. & Mays, L.W. (1988). Applied Hydrology. McGraw-Hill (alternating-block method, §14.4).
  • Kansas City Metro Chapter APWA (2025). Section 5600 Storm Drainage Systems and Facilities, Version 2025.01.
  • Mile High Flood District (Denver). Urban Storm Drainage Criteria Manual (90% release rationale).
  • Department of Irrigation and Drainage Malaysia (2008, 2012). Urban Stormwater Management Manual (MSMA).

Annexes

Annex Content
2A NIH-DHAARA vs IMD station and IMD gridded checks at benchmark points; zone map
2B Sub-daily ratios P(t)/P(24h) by zone: NIH-DHAARA (hourly-based) vs the one-third rule
2C Grid-to-point factors
2D Arunachal Pradesh temporal patterns (Huff curves)
2E Retention percentile depths by zone
Form 2-1 Design Rainfall Sheet